Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B13-0188 APPLICATION, LOAD CALCS AND ASBESTOS TEST RESULTS
******************************************************************************************** TOWN OF VAIL, COLORADOCopy Reprinted on 05-29-2013 at 10:12:31 05/29/2013 Statement ******************************************************************************************** Statement Number: R130000687 Amount: $1, 082.74 05/29/201310: 12 AM Payment Method:Credit Crd Init: DR Notation: MC LUKE RICHTER ----------------------------------------------------------------------------- Permit No: B13-0188 Type: COMBINATION BLDG PERMIT Parcel No: 2103-014-1401-9 Site Address: 1150 SANDSTONE DR VAIL Location: UNIT B Total Fees: $7, 751. 99 This Payment: $1, 082.74 Total ALL Pmts: $1, 082.74 Balance: $6, 669.25 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 1, 082.74 ----------------------------------------------------------------------------- Department of Community Development 75 South Frontage Road TOWN OF VAIL` Vail, CO 81657 Tel: 970-479-2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm &sprinkler) Project Street Address: Project#: &TJ_3-OL 71 !150 5,�AwTo"L16 i�yC np (Number) (Street) (Suite#) � Q Q Building Permit#: Building/Complex Name: Contractor Informatio Lot#: Block# Subdivision: Business Name: ST�FF Work Class: New a Addition � Alterations Business Address: City State: Zip: 3 Type of Building: Single-Family 0 Duplex Multi-Family Contact Name: )Cw Ee-, _ Commercial 0 Other Contact Phone: 270 - 3 6 _3�SS Contact E-Mail: luk,- m-cL it e� Meg , cgwLWork Type: Interior Q) Exterior c) Both I hereby acknowledge that I have read this application,filled out Valuation of in full the information required,completed an accurate plot plan, Work Included PI ns Included Work and state that all the information as required is correct. I agree to Electrical Yes O)No )Yes ©)No comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to Mechanical jYes O)No O)Yes OjNo oao the town's zoning and subdivision codes, design review ap- v proved,International Building and Residential Codes and other Plumbing Yes O)No 0Yes O)No �� ordinances of the Town plicable thereto. Building PYes O)No Q&es O)No l � X --� -- Value of all work being performed: Owner/O per's Re/presentative Signature(Required) (value based on IBC Section 109.3&IRC Section 108.3) Electrical Square Footage Applicant Information Detailed Scope and Location of Work: 14//(-76- Applicant Name: (.Jwi b"JSm ' 720o- -IE ka- 1F � Applicant Phone: L Applicant E-Mail: �EM617�L L?c1EST /5,�-T�f�� Project Information Q7— & /cit Owner Name: / jUly / 4010 I 4x 4q1 )44 / Parcel#: (For Parcel#,contact Eagle County Assessors Office at(970-328-8640 or visit www.eaglecounty.us/patie) (use additional sheet if necessary) For Office Use Only: Fee Paid: Date Received: W R Received From: D V Cash Check# MAY 2 8 2013 O� Visa/ MC Last 4 CC# exp date: Auth# TOWN OF VAIL - - 12 Design Review Board ACTION FORM Department of Community Development 01�L 75 South Frontage Road, Vail, Colorado 81657 (�j� ttel: 970.479.2139 fax: 970.479.2452 ;•.,.,,,.,-,��_,,,,L.:,.,„E•.- web: www.vailgov.com Project Name: FRIEDMAN ADDITION / WINDOWS DRB Number: DRB130133 Project Description: ADDITION OF 100 SQUARE FOOT UNDER THE 250 GRFA ADDITION RULE. EXPANSION OF EXISTING DECK, REPLACEMENT OF ALL WINDOWS. ALL NEW MATERIALS TO MATCH THE EXISTING MATERIALS. Participants: OWNER FRIEDMAN, KENNETH 0. 05/03/2013 1150 B SANDSTONE DR VAIL, CO 81657 APPLICANT FRIEDMAN, KENNETH 0. 05/03/2013 1150 B SANDSTONE DR VAIL, CO 81657 Project Address: 1150 SANDSTONE DR VAIL Location: UNIT B Legal Description: Lot: A-7 Block: 15 Subdivision: CASOLAR VAIL Parcel Number: 2103-014-1401-9 Comments: See Conditions BOARD/STAFF ACTION Motion By: Action: STAFFAPP Second By: Vote: Date of Approval: 05/21/2013 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS. Cond: 202 (PLAN): Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Planner: Joe Batcheller DRB Fee Paid: $300.00 Lutter Electric, LLC. Load Calculation for 1150 B Sandstone Drive Vail Colorado: 2385 Sq.ft. @ 3VA 7,155 VA Kitchen small appliance X 2 3,000 VA Dishwasher 1,200 VA Disposal 1,200 VA Range 10,200 VA Laundry 1,500 VA Dryer 5,000 VA Water Heater 4,500 VA Total 33,755 VA First 10kVA of general load @ 100% 10,000 VA Remainder of general load @ 40% 9,502 VA Heat 1,500 VA Total 21,002 VA 21,002 VA @ 240 volt= 87.5A Existing service is 200A... l:ir�frzfrtx����txtxtl ;, Iii;�e~��1t:r }2c;xtc}rzrt�=. Date: 05-22-2013 Asbestos Sampling Report Page: 1/ 1 To: Luke Ritcher Regarding: 1150 B Sandstone Dr Vail, CO Mr. Ritcher, On 05-16-13, ECOS Environmental & Disaster Restoration Inc. conducted a limited asbestos inspection of VISIBLE suspect ACM (asbestos containing materials) that would be disturbed per the remodeling scope of work. If other suspect materials become visible/apparent during demolition or construction, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. A limited bulk sampling of suspect ACM was conducted in accordance with Colorado State Requirements. Said requirements state for surfacing materials: each homogenous area of less than 1000 SF, a minimum of three samples must be collected randomly. For each homogenous area of 1000-5000 SF, a minimum of five samples must be collected. For areas larger than 5001 SF a minimum of seven samples must be collected, respectively. For miscellaneous materials at least one sample must be taken. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. Joshua Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401, performed the inspection. Samples taken were sent to the lab Aerobiology Laboritory, for PLM (Polarized Light Microscopy) analysis. DESCRIPTION OF SAMPLING AREA Acoustic texture ceilings throughout house, kitchen & sunroom suspect ACM SUSPECT MATERIALS SAMPLED Drywall, Tape, Joint Compound, and Texture CONCLUSIONS No asbestos was detected. ➢• { �'a 4 - 4 S ➢ f;� ¢ �Y STATE OF COLORADO ASBESTOS CERTIFICATION* Colorado Department of Public Health and Environment Air Pollution Control Division This certifies that Joshua Jay Johnson Certification No: 18401 has met the requirements of 15-7-507, C.R.S. and Air Quality Control Commission Regulation No. 8, Part B, and is hereby certified by the state of Colorado in the following discipline: „ Building Inspector Issued: 6/17/2012 Expires on: 6/17/2013 Authorized APCD Representative *T his certificate is valid oiilp x ith the possession of a curreiiI INNsio;i-approved training course certification in the discipline specified above. ` k SEAL 77 ,7 I� <` `,t' k t, ib ., iasrr �' ?. ,� q °3 *„,a':a k �a .Mr+, l � s s.�','�-_ �.. �v ./«+• s � �1 � a�r � 'ei��`+'" � ,K ���t �!r`i �� � ° ',4Y. � ,'�' Sample Identification Physical Description of Sample/Layer Homo- geneous (Y/N) 780 Simms Street ladLdigL� /�F- I....Ai7�7f2A"fK')Cty Asbestos Percentage Non-Asbestos Fiber Percentage Suite 104 f2CYf7!l7Il7C�y Client Golden, CO,80401 ASS[X:IA11-S,INC:<)Ith[>ItA1FF.> White Foamy Texture w/White Paint N 303.232.3746 ! res�eC Certificate of Analysis www.aerobiology.net 100 Client Name ECOS Environmental F,\ Date Collected: 05/16/13 Street address 6690 Hwy 82 rr/uo Date Received: 05/17/13 City,State ZIP Glenwood Springs,CO 81601 100 Date Analyzed: 05/17/13 Attn: Josh Johnson NVLAP Lab Code 200860-0 Date Reported: 05/17/13 Client Project Name: MastifY 051613 Project ID: 13006284 G,C 1150 B1 Job ID White Compound w/White Paint Test Requested: 3002,Asbestos in Bulk Samples 15% ND Method: Polarized Light Microscopy/Dispersion Staining(PLM),Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/116,July 1993. 100 G Sample Identification Physical Description of Sample/Layer Homo- geneous (Y/N) Layer Percentage Asbestos Detected Asbestos Percentage Non-Asbestos Fiber Percentage Non-Fibrous Material Percenta a Matrix Material Composition Client Lab Sam le Number 1150 Al 13006284-1 White Foamy Texture w/White Paint N 100% ND 100 C 1150 A2 13006284-2 White Foamy Texture N 100% ND 100 G,C 1150 A3 13006284-3 White Foamy Texture w/White Paint N 100% ND 100 G,C 1150 B1 13006284 4A White Compound w/White Paint N 15% ND 100 G 13006284-413 Tan/White Drywall N 85% ND 10 90 G 1150 B2 13006284-5A White Compound w/White Paint N 10% ND 100 G 13006284-513 Tan/White Drywall N 90% ND 10 90 G 1150 B3 13006284-6A White Compound w/White Paint N 15% ND 100 G 13006284-6B Tan/White Drywall N 85% ND 10 90 G Richard egryzn 9-44- Ron Weyand Asbestos Laboratory Supervisor A=Amosite Q=Quartz P=Perlite AC=Actinolite C=Carbonates B=Binder AN=Anthophyllite G=Gypsum D=Diatoms CHRY=Chrysotile M=Mica CR=Crocidolite T=Tar TR=Tremolite NTR=Non-Asbestiform TR Trace=Less Than I% NAC=Non-Asbestiform AC ND=None Detected Page 1 of 2 780 Simms Street, Suite 104,Golden,CO,80401,303.232.3746 X1,1 12(>1AC>lC)CJY I_.AI31C)12AiC>1ry ASSOCIATES, INCORI-ORATED Certificate of Analysis ECOS Environmental 6690 Hwy 82 Glenwood Springs,CO 81601 Josh Johnson Client Project Name: Mastiff 051613 General Notes ND indicates no asbestos was detected;the method detection limit is 1 %. a�aa��y NVLAP Lab Code 200860-0 Trace or"<I"indicates asbestos was identified in the sample,but the concentration is less than 1%. 780 Simms Street Suite 104 Golden,CO,80401 303.232.3746 www.aerobiology.net Date Collected: 05/16/13 Date Received: 05/17/13 Date Analyzed: 05/17/13 Date Reported: 05/17/13 Project ID: 13006284 Job ID: ♦ All regulated asbestos minerals(i.e.chrysotile,amosite,crocidolite,anthophyllite,tremolite,and actinolite)were sought in every layer of each sample,but only those asbestos minerals detected are listed.Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunerite. Crocidolite is the common name used for the asbestiform variety of the mineral riebeckite. ♦ Tile,vinyl,foam,plastic,and fine powder samples may contain asbestos fibers of such small diameter(<0.25 microns in diameter)that these fibers cannot be detected by PLM. For such samples,more sensitive analytical methods(e.g.TEM,SEM,and XRD)are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM floor tile analysis is accepted under NESHAP regulations. ♦ These results are submitted pursuant to Aerobiology Laboratory Associates,Inc.'s current terms and conditions of sale,including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted. ♦ Unless notified in writing to return the samples covered by this report,Aerobiology Laboratory Associates,Inc.will store the samples for a minimum period of thirty(30)days before discarding. A shipping and handling charge will be assessed for the return of any samples. ♦ Aerobiology does not guarantee the results of tape lifts,microvacs,wipe,and/or debris samples. Accurate analysis cannot be performed due to particle size,media used,and/or amount of material given. Analysis of these materials should be preformed by a TEM. A result of ND does not indicate that the sample area does not contain asbestos. It means the analyst could not identify asbestos in the specific sample for the reasons listed above. Notes Required by NVLAP ♦ This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST,or any agency of the Federal Government. ♦ This test report relates only to the items tested or calibrated. ♦ This report is not valid unless it bears the name of a NVLAP-approved signatory. ♦ Any reproduction of this document must include the entire document in order for the report to be valid. Page 2 of 2 780 Simms Street, Suite 104,Golden,CO,80401,303.232.3746