Loading...
HomeMy WebLinkAboutB13-0201 Department of Community Development 75 South Frontage Road West Vail, CO 81657 TOWN OF VA I L ' Tel: 970479-2128 Community Development www.vailgov.com Department Development Review Coordinator WINDOW REPLACEMENT PERMIT APPLICATION (This permit is applicable to one and two family dwelling units only) (Permit fee = standard building fees and design review fee) Project Information Type of Building: Owner Name: RAUH-RYAN, LYNN - RYAN, TIMOTHY One Family( )Two Family(Duplex)(F-) Multi-Family( v ) Parcel#: 2101-034-02-008 Submittal Requirements: (For Parcel#,contact Eagle County Assessors Office at(970-328-8640 or visit www.eaglecounty.us/patie) • Joint Property Owner Written Approval Letter(duplex or multi-family HOA) Project Street Address: • Two(2)plan sets indicating: 2875 Manns Ranch Road C2 • Floor plans showing window location(s)and eleva- (Number) (Street) (Unit#) tions(window schedule may be substituted for eleva- tions) Contractor Information • Emergency egress requirements in bedrooms • Size of windows and openings Business Name: Reconstruction Experts • U-Value of windows • Material, cut sheets and color of windows(must Business Address: 5310 Vivian St match style and color of building) City Arvada State: co Zip: 80002 • Full view elevation photos of all sides of building Detailed Scope and Location of Work: 10 Window Replacement Contact Name: Matt Bribach See Attached Contact Phone: 970-409-0161 Contact E-Mail: mbribach @reconstructionexperts.net (use additional sheet if necessary) Applicant Information(fill in if different from contractor) Valuation Applicant Name: Work Included Plans Included of Work Applicant Phone: Electrical (, )Yes (t )No (( )Yes t )No Applicant E-Mail: Mechanical C)Yes ((-)No ((')Yes (-)No I hereby acknowledge that I have read this application, filled out in Plumbing (;7)Yes (( jNo ((-)Yes C')No full the information required,completed an accurate site plan, and state that all the information as required is correct. I agree to Building (,,7)Yes ( No ((')Yes ( )No 7190 comply with the information and site plan, to comply with all Town ordinances and state laws, and to build this structure according to Value of all work being performed: $ 7190 the town's zoning and subdivision codes, design review approval, (value based on IBC Section 109.3&IRC Section 108.3) International Building and Residential Codes and other ordinances of the Town applicable thereto. Date Received: Owner/Owner's Representative Signature Required(typed or digital D L� signature) MAY 20 2013 ( ) Checking this box indicates you are electronically signing this application and agree to the above statement. TOWN OF VAIL For Office Use Only: Project#: f rn -o a3 0 Fee Paid: ^ Received From: Building Permit#: - �o(C) Cash Check# CC: Visa/MC Last 4 CC# Auth#: Lot#: Block#-L Subdivision: U.Vb �L 3 ` 12-Sep 20 TOWN OF VAIL JOINT PROPERTY OWNER WRITTEN APPROVAL LETTER The applicant must submit written joint property owner approval for applications affecting shared ownership properties such as duplex, condominium, and multi-tenant buildings. This form, or similar written correspondence, must be com- pleted by the adjoining duplex unit owner or the authorized agent of the home owner's association in the case of a con- dominium or multi-tenant building. All completed forms must be submitted with the applicants completed application. I, (print name) Pam Stenmark , a joint owner, or authority of the association, of property located at 2875 Manns Ranch Road, Unit C2 -Vail, Colorado 81657 , provide this letter as written approval of the plans dated which have been submitted to the Town of Vail Community Development Department for the proposed improvements to be completed at the address not- ed above. I understand that the proposed improvements include: Replacement of 10 Windows I understand that modifications may be made to the plans over the course of the review process to ensure compliance with the Town's applicable codes and regulations; and that it is the sole responsibility of the applicant to keep the joint property owner apprised of any changes and ensure that the changes are acceptable and appropriate. Submittal of an application results in the applicant agreeing to this statement. ��4 S Ian Signature Date �jk tK E<,A S 7 C—W ik Print Name �w. �� + tab;� t � �d r ✓ � #� �r b� ..,� `a"' � r.� 6•,t'� P � x � :i ,r. r.,y9d"ew- � �µ,,•w:. r g Nly It t i , d--mow i ��Mi'�tc: ..�,'. .,.�"v.+�w.s4kesu•+svyc 4d �> k.� ..G� ., T —.. Ilk r_ a as- .n t a . . NMI' Wo + , + t , � s , '. . � ���,�� � des �r`t'Y,,�* �,++� -�`""""• Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number:4502983 [_Um_#_ Location: Attributes 175 C2-Living ProLine, Casement Right,33 X 59, Brown, 4-9116" Item Price Qty Ext'd Price $IMF 1 �� 1:Non-Standard Size Right Casement PK# Frame Size:33 X 59 559 General Information: Clad 1 Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior = Glass: Insulated Tempered Low E SunDefense High Altitude Viewed From Exterior Hardware Options:Standard Roto Operator, Champagne Rough Opening: 2'93/4'X4'113/4" Screen:Full Screen,Champagne,InView Grille: Final Wall Depth: 4-9116" Wrapping Information: Foldout Fins, Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied, Perimeter Length=184",Glazing Pressure =205. Line# Location: Attributes 180 C2-Living ProLine, Casement Fixed, 33 X 59, Brown, 4.9116" Item Price Qty Ext'd Price 1:Non-Standard Size Fixed Casement PK# Frame Size:33 X 59 I 559 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass: Insulated Tempered Low E SunDefense High Altitude Viewed From Exterior Grille: Rough Opening: 2'93/4"X4'113/4' Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length= 184",Glazing Pressure =205. Final Wall Depth: 4-9/16' Line# Location: Attributes 185 CZ-Living ProLine, Casement Fixed, 33 X 59, Brown,4-9116" Item Price Qty ExVd Price 1:Non-Standard Size Fixed Casement PK# Frame Size:33 X 59 559 General Information: Clad I Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass:Insulated Low E SunDefense High Altitude Viewed From Exterior Grille: Rough Opening: 2'9 3/4"X 4'11 3/4" Wrraapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length=184",Glazing Pressure Final Wall Depth: 4-9/16' For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at www.pella.com Printed on 4/30/2013 Detailed Proposal Page 20 of 35 Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number:4502983 Line# Location. Attributes 190 C2-Living ProLine, Casement Left, 33 X 59, Brown, 49/16" Item Price aty Exrd Price 1:Non-Standard Size Left Casement PK# Frame Size:33 X 59 General Information: Clad 559 Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior -~ Glass: Insulated Low E SunDefense High Altitude Viewed From Exterior Hardware Options:Standard Roto Operator, Champagne Rough Opening: 2'93/4"X4'113/4" Screen:Full Screen,Champagne, Inview Grille: Final Wall Depth: 4-9/16" Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length=184",Glazing Pressure =60. Line# Location: Attributes 195 C2 Entry ProLine,Casement Right,25 X 53, Brown,49/16" Item Price City Exrd Price 1:2553 Right Casement PK# Frame Size:25 X 53 559 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior —'` - Glass: Insulated Tempered Low E SunDefense High Altitude Viewed From Exterior Hardware Options:Standard Roto Operator, Champagne Rough Opening: 2'13/4'X 4'5 3/4' Screen:Full Screen,Champagne,Inview Grille: Final Wall Depth: 4-9/16' Wrapping Information: Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length= 156",Glazing Pressure =205. Line# Location: Attributes 200 C2-kitchen ProLine, Casement Left, 25 X 35, Brown, 49/16" Item Price City Ext'd Price 1 wow 1:2535 Left Casement PK# Frame Size:25 X 35 559 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass: Insulated Low E SunDefense High Altitude Viewed From Exterior Hardware Options:Standard Roto Operator, Champagne Rough Opening: 2'13/4"X2'113/4" Screen:Full Screen,Champagne,InView Grille: Final Wall Depth: 4-9/16" Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length=120",Glazing Pressure =95. For more information regarding the finishing, maintenance, service and warranty of all PellaS products, visit the Pella®website at www.pella.com Printed on 4/30/2013 Detailed Proposal Page 21 of 35 Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number:4502983 Llnei Location: - ____ Att ributes 205 C2-Loft ProLine, 4-Wide Casement, 97 X 41.5, Brown, 4-9116" Item Price Qty Ext'd Price 1 - 1: Non-Standard Size Fixed Casement PKik Frame Size:22 X 41 1/2 559 General Information: Clad Exterior Color/Finish:Standard EnduraClad, Brown Interior Color/Finish:Unfinished Interior Glass: Insulated Low E SunDefense High Altitude Viewed From Exterior Grille: Rough Opening: 8'1 3/4'X T6 1/4" Vertical Mull 1:FactoryMull,Standard(Vertical Factory)(0") 2: Non-Standard Size Left Casement Final Wall Depth: 4-9/16" Frame Size:261/2 X 41 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass: Insulated Low E SunDefense High Altitude Hardware Options:Side Pivot Hardware, Champagne Screen:Full Screen,Champagne,InView Grille: Vertical Mull 2:FactoryMull,Standard(Vertical Factory)(0") 3:Nonstandard Size Right Casement Frame Size:26 1/2 X 41 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass: Insulated Low E SunDefense High Altitude Hardware Options:Standard Roto Operator, Champagne Screen:Full Screen,Champagne,InView Grille: Vertical Mull 3: FactoryMull,Standard(Vertical Factory)(0') 4:Non-Standard Size Fixed Casement Frame Size:22 X 41 112 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass: Insulated Low E SunDefense High Altitude Grille: Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied, Perimeter Length=277",Glazing Pressure =75. For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at www.pella.com Printed on 4/30/2013 Detailed Proposal Page 22 of 35 Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number:4502983 Line 8 Location: Attributes 210 C2-Bath ProLine,2-Wide Casement, 48.5 X 41.5, Brown,4-9116" Item Price Qty Ext'd Price 1:Nonstandard Size Left Casement PK# Frame Size:24 1/4 X 41 1/2 559 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish: Unfinished Interior Glass: Insulated Tempered Low E SunDefense High Altitude Viewed From Exterior Hardware Options:Standard Roto Operator, Champagne Rough Opening: 4'1 1/4'X T6 1/4' Screen: Full Screen,Champagne,InView Grille: Final Wall Depth: 4-9/16" Vertical Mull 1: FactoryMull,Standard(Vertical Factory)(0') 2:Nonstandard Size Right Casement Frame Size:24 1/4 X 41 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass: Insulated Tempered Low E SunDefense High Altitude Hardware Options:Standard Roto Operator, Champagne Screen: Full Screen,Champagne, InView Grille: Wrapping Information: Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length= 180",Glazing Pressure =205. For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at www.pella.com Printed on 4/30/2013 Detailed Proposal Page 23 of 35 Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number:4502983 Line 11 Location: — -- ----------- AtMbutes 215 C2-Lower Beds ProLine, 4-Wide Casement, 96.5 X 51.5, Brown, 49116" Item Price City Ext'd Price 2 1:Non-Standard Size Fixed Casement a PK# Frame Size:23 1/4 X 51 112 General Information: Clad 559 Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass:Insulated Low E SunDefense High Altitude Viewed From Exterior Grille: Rough Opening: 8'1 1/4'X 4'4 1/4' Vertical Mull 1:FactoryMull,Standard(Vertical Factory)(0') 2:Non-Standard Size Left Casement Final Wall Depth: 4-9/16" Frame Size:25 X 51 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish: Unfinished Interior Glass: Insulated Low E SunDefense High Altitude Hardware Options:Side Pivot Hardware, Champagne Screen:Full Screen,Champagne, InView Grille: Vertical Mull 2:FactoryMull,Standard(Vertical Factory)(0") 3:Non-Standard Size Right Casement Frame Size:25 X 51 1/2 General Information: Clad Exterior Color I Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass: Insulated Low E SunDefense High Altitude Hardware Options:Standard Roto Operator, Champagne Screen:Full Screen,Champagne,InView Grille: Vertical Mull 3:FactoryMull,Standard(Vertical Factory)(0") 4:Non-Standard Size Fixed Casement Frame Size:23 1/4 X 51 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass: Insulated Low E SunDefense High Altitude Grille: Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied, Perimeter Length=296",Glazing Pressure =55. For more information regarding the finishing, maintenance, service and warranty of all Pella®products, Visit the Pella®website at www.pella.com Printed on 4/30/2013 Detailed Proposal Page 24 of 35 ARCHITECT DESIGNER OPTIONS PROLINE- FIXED Clear Insulating Glass Argon-oiled, Low-E Insulating • Glass* • Dual Glazing with Between- • the-Glass Options • Triple Glazing with Between- the-Glass Options • Laminated Glass Impact Resistant aanels Tinted Glass • Reflective Glass Spandrel glass or High-aftitude Lowi insulating glass does n ntain argon gas. !CASEMENT WINDOW PERFORMANCE �--� NFRC U-value Total Unit I U. 0.51 6.23-0.49 0 0.29-0.5 0.29-0.5 3 Design Pressure* (psf) 40-75 50-70 30-50 20-90 Structural Test Pressure(psf) 0- 113 75- 105 45- 75 30- 135 Water Penetration no e @ 7.5 psf one @ 10.5 psf none @ 7.5 psf none 15psk Air Infiltration (@ 1.57 psf) 0.05 cfm 0.05 cfm— 4 0.05 cfm 0.05 cfm *Performance class and grade rating nd related hal a certification appy to single units only with appropriate glass options and not the combined or composite units. 'For 48"x 48"windows ;CENTER GLASS IPERFORMANCE Winter NFRC U-value 0.25-0.5 0.16-0.50 .25-0.51 0,25-0.51 Solar Heat Gain Coefficient 0.32 0.7 .26-0.79 7 0.41-0.79 0.32-0.79 Shading Coefficient 6.37-0y,91 0\Y 1-0.91,% 0.47-0.91 0.37 -0.91 %UV Transmission 1 7- 2 -63 16-62 7- 62 LBL Fading Damage' 0. -0.64 0.15 0.65 0.33-0.64 0.18-0.64 %Visible Light Transmission -83 33 `3 72-83 40-83 "Developed by Lawrence Berkeley Lab at s,the LBL damage fund n Is a better predictor of fading damage than UV transmission. Lower values Indicate less fading po nGal.( TE:This valued not nsider visible light.) - ' • PERFORMANCEr' STC Rating 27-36 33-38 28-29 OITC Rating 22-32 26 31 23-26 ['Performance based on standard glass options. i, 'f• �^E?� �;�F � h� +� �� < �.� M� "�' S: t '�, � r ��, a ���tiA r�jY�.. { t�� t ,.,:s �`. ,':�1 � �r�i � . .:�: . �`" .,�, ��� .. .,r' �n, �a. , . .... .. , 1�' ...,�,�. h i� �, � h � vY' �,: ri ���� 'i.,� - r } ,. ��, i it � + � ,� ,�� �.� ��� � .�,. 'Y�y4' �. °:w � �b a j �, � '`'�4,', r . *!�, Y N ,.,�,,,i.. �tE •�'���Y w Lry4 y. �� < M ^ ,�#`,, ���tiA r�jY�.. { t�� t ,.,:s �`. ,':�1 � �r�i � . .:�: . �`" .,�, ��� .. .,r' �n, �a. , . .... .. , 1�' ...,�,�. h i� �, � h � vY' �,: ri ���� 'i.,� - r } ,. ��, i it � + � ,� ,�� �.� ��� � .�,. 'Y�y4' rA 0 ,>,<�j Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number;4502983 tine KI t.ocaUon: 175 f C2-Living PK# 559 Viewed From Exterior Rough Opening; Z93/4'X4'1139' Final Wall Depth: 4-9116' 180 C2-Living I PK# 559 Viewed From Exterior Rough Opening: 7939'X4'11314' Final Wall Depth: 4-9/16" 185 C2-Living I = PK# f 559 Viewed From Exterior Rough Opening: 2'939'X4'1139' Final Wall Depth: 4-9/16' ProLine, Casement Right, 33 X 59, Brown,49/16" Item Price __atY ExCd Price 1:Nonstandard Size Right Casement Frame Size:33 X 59 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass:Insulated Tempered Low E SunDefense High Altitude Hardware Options:Standard Roto Operator, Champagne Screen:Full Screen,Champagne,InView Grille: Wrapping Information:Foldout Fins,Factory Applied,4-9/16 Standard 4-sided Jamb Extension,=205. Factory Applied,Perimeter Length=184",Glazing Pressure ProLine, Casement Fixed, 33 X 59, Brown,49/16" Item Price Qty Ext'd Price 1:Nonstandard Size Fixed Casement 1 Frame Size:33 X 59 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass:Insulated Tempered Low E Sunpefense High Altitude Grille: Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length=184",Glazing Pressure =205. ProLine, Casement Fixed, 33 X 59, Brown,49/16" Kam Price Qty ExCd Price 1:Nonstandard Size Fixed Casement 1 Frame Size: 33 X 59 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass:Insulated Low E SunDefense High Altitude Grille: Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length=184",Glazing Pressure =60. For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at www.pella.com Printed on 4/30/2013 Detailed Proposal Page 20 of 35 Customer: Reconstruction Experts Project Name: Booth Creek Townhomes L Quote Number:4502983 1.111110 111 190 I f� PK# '% 559 Viewed From Exterior Rough Opening: 2 9 3/4"X 4'11 3/4' Final Wall Depth: 4-9/16' 195 C2-Entry P �` PK# 559 Viewed From Exterior Rough Opening: 2 13/4'X 4'5 3/4' Final Wall Depth: 4-9/16' 200 C2-Kitchen PK# 559 Viewed From Exterior Rough Opening: 2'139"X 2'1139' Final Wall Depth: 4-9/16' ProLine, Casement Left, 33 X 59, Brown, 49/16" Item Price Qty Exrd Price 1:Non-standard Sin Left Casement Franca stns:33 X 59 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass: Insulated Low E SunDefense High Attitude Hardware Options:Standard Roto Operator, Champagne Screen:Full Screen,Champagne,InView Grille: Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length=184",Glazing Pressure =60. ProLine,Casement Right,25 X 53, Brown,49116" Item Price Qty Exrd Price 1:2553 Right Casement Frame Size:25 X 53 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass: Insulated Tempered Low E SunDefense High Attitude Hardware Options:Standard Roto Operator, Champagne Screen:Full Screen,Champagne,InView Grille: Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length=156",Glazing Pressure =205. ProLine, Casement Left, 25 X 35,Brown,49116" 1:2535 Left Casement Frame Size:25 X 35 GenerallnformaUon: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color!Finish:Unfinished Interior Glass:Insulated Low E SunDefense High Altitude Hardware Options:Standard Roto Operator, Champagne Screen:Full Screen,Champagne,InView Grille: ftem Price Qty Exrd Price � 1 � Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length=120",Glazing Pressure =95. For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at com Printed on 4/30/2013 Detailed Proposal www.pella Page 21 of 35 Customer: Reconstruction Experts Project Name: Booth Creek Townhomes LMe Quote Number:4502983 C2 --------------- ProLlne, 4-Wide Casement, 97 X 41.5, Brown,4-9116" Itatt Prks Qty ExYd Price f. 1:Non-Standard Size Fixed Casement PK# Frame Size:22 X 41 1/2 559 General Information: Clad -` - -> Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Viewed From Exterior Glass: Insulated Low E SunDefense High Altitude Grille: Rough Opening: 8'1 3/4"X T6 1/4" Vertical Mull 1:FactoryMull,Standard(Vertical Factory)(0') Final Wall Depth: 4-9/16" 2:Non-Standard Size Left Casement Frame Size:26 1/2 X 41 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass:Insulated Low E SunDefense High Altitude Hardware Options:Side Pivot Hardware, Champagne Screen: Full Screen,Champagne,InView Grille: Vertical Mull 2:FactoryMull,Standard(Vertical Factory)(0") 3:Nonstandard Size Right Casement Frame Size:26 1/2 X 41 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish: Unfinished Interior Glass: Insulated Low E SunDefense High Altitude Hardware Options: Standard Roto Operator, Champagne Screen: Full Screen,Champagne,InView Grille: Vertical Mull 3:FactoryMull,Standard(Vertical Factory)(o') 4:Nonstandard Size Fixed Casement Frame Size:22 X 41 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass:Insulated Low E SunDefense High Altitude Grille: Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied, Perimeter =75. ", Length=277 Glazing Pressure For more information regarding the finishing, maintenance, service and warranty of all Pella®products, Printed on 4/30/2013 Detailed Proposal visit the Pella®website at www.pella.com Page 22 of 35 Customer: Reconstruction Experts Project Name: Booth Creek Townhomes lh�a Locatlon: Quote Number.4502983 210 C2-Bath Aft ributss ProLine,2-Wide Casement,48.5 X 41.5, Brown,4-9/16" K,t PrkO aY Exrd Prlco 1 >i 1 1: Nonstandard Size left Casement :. PK S Frame Size:24 1/4 X 41 112 559 Generallnformation: Clad I Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Viewed From Exterior Glass:Insulated Tempered Low E SunDefense High Attitude Hardware Options:Standard Roto Operator, Champagne Rough Opening: 4'1 1/4'X T6 1/4' screen:Full Screen,Champagne,InView Final Wall Depth: 4-9/16' Vertical Mull 1:Facto Mull,Standard ry (Vertical Factory)(0'l 2:Non-Standard Sits Right Casement Frame Size:24 1/4 X 41 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass:Insulated Tempered Low E SunDefense High Attitude Hardware Options:Standard Roto Operator, Champagne Screen: Full Screen,Champagne, InView Grille: Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length =205. ", = 180 Glazing Pressure For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at www.pella.com Printed on 4/3012013 Detailed Proposal Page 23 of 35 Customer: Reconstruction Experts Project Namem Booth C une r n: reek Townhomes Quote Number:4502983 215 C2-Lower Beds ' ProUne,4-Wide Casement, 96,5 X 51.5, Brown, 49/16" u- % '� 1:Non-Standard Size Fixed Casement f PK 0 Frame Sias:23 1/4 X 51 1/2 559 General information: Clad _._ _ Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Viewed From Exterior Glass:Insulated Low E SunDefense High Attitude Grimm: Rough Opening: 8'1114'X 4'4 1/4" Vertical Mull 1:FactoryMull,Standard(Vertical Factory)(0") 2:Non-Standard Sits left Casement Final Wail Depth: 4-9/16" Frame Size:25 X 51 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish: Unfinished Interior Glass:Insulated Low E SunDefense High Altitude Hardware Options:Side Pivot Hardware, Champagne Screen:Full Screen,Champagne,InView Grille: Vertical Mull 2:FactoryMull,Standard(Vertical Factory)(0") 3:Nonstandard Sits Right Casement Frame Size:25 X 51 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish: Unfinished Interior Glass:Insulated Low E SunDefense High ARitude Hardware Options:Standard Roto Operator, Champagne Screen:Full Screen,Champagne,InView Grille: Vertical Mull 3:FactoryMull,Standard(Vertical Factory)(0") 4:Nonstandard Sirs Fixed Casement Frame Size:23 1/4 X 51 1/2 General information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass:Insulated Low E SunDefense High Attitude Grille: them Price Qty Exrd Price 2 Wrapping Information:Foldout Fins,Factory Applied,49116"Standard 4-sided Jamb Extension,Factory Applied, Perimeter Length=296^,Glazing pressure 55. For more information regarding the finishing, I maintenance, service and warranty of all Pella®products, Printed on 4/30/2013 Detailed P— visit the Pella®website at www.pella.com pees Page 24 of 35 ARCHITECT DESIGNER GLAZING OPTIONS SERIES SERIES' . . • Clear Insulating Glass Argon-filled, Low-E Insulating • Glass* • . • Dual Glazing with Between- • the-Glass Options Triple Glazing with Between- the-Glass Options Laminated Glass Impact Resistant Glass Tinted Glass • Reflective Glass • • Spandrel glass or panels High-aftitude Low-E insulating glass does no ntain argon gas. ,WINDOW iCASEMENT PERFORMANCE --�� NFRC U-value Total Unit .23-0.49 0.29-0.50 0.29 0.5 3 Design Pressure*(psf) 0-75 SO- 70 30- 50 20.90 Structural Test Pressure(psf) qtinnd - 113 75- 105 45-75 30- 135 Water Penetration @ 7.5 psf one @ 10.5 psf none @ 7.5 psf none @ 15 psk Air Infiltration (@ 1.57 psf) 05 cfm 0.05 cfm 0.05 cfm 0.05 cfm *Performance class and grade r , related hal a ce rtiflcation apply to single units only with appropriate glass options and not the combined Or composite units. 'For 48"x 48"windows CENTER GLASS PERFORMANCE Winter NFRC U value 1111111111k, 0.25-0.51 0.16-0.50 0.25-0.51 0.25-0.51 Solar Heat Gain Coefficient '0.32-0.77 .26-0.79 0.41-0.79 0.32-0.79 Shading Coefficient .37- .91 10111 1-0.91: 0.47-0.91 0.37 - 0.91 %UV Transmission 7- 2 -63 16 62 7- 62 LBL Fading Damage" 0. 0.64 0.15 0.65 0.33 0.64 0.18-0.64 %Visible Light Transmission 83 33- 3 72-83 40-83 "Developed by Lawrence Berkeley Lab atones,the LBL damage funct n is a better predictor of fading damage than UV transmission. Lower values indicate less fading po nUal.( TE: This value&i not nsider visible light.) 'SOUND TRANSMISSION PERFORMANCEr' STC Rating 27- 36 33-38 28-29 28- 36 OITC Rating 22-32 26- 31 23-26 24- 32 5Performance based on standard glass options. I • 02-07-2014 Inspection Request Reporting \ Page 19 4:02 pm Vail, CO - City Of ( l3' 0Z Requested Inspect Date: Monday,February 10,2014 Site Address: 2875 MANNS RANCH RD VAIL BOOTH CREEK TOWNHOUSES UNIT C2 A/P/D Information Activity B13-0201 Type: COMBO Sub Type: AMF Status: ISSUED Const Type Occupancy: Use: R-2 Insp Area: Owner RAUH-RYAN, LYNN-RYAN,TIMOTHY Contractor: RECONSTRUCTION EXPERTS INC Phone: 303-783-2562 Description: WINDOW REPLACEMENTS FOR UNITS C2, D1, D2 AND D3 AT BOOTH CREEK TOWNHOUSES. Requested Inspection(s) Item. 90 BLDG-Final Requested Time: 03:00 PM Requestor Phone: Comments follow us Assigned To J■ • WAGON Entered By: JMONDRAGON K Action "Air Time Exp: Inspection History Item: 30 BLDG-Framing **Approved** 07/02/13 Inspector: JRM Action: AP APPROVED Comment: APPROVED U VALUES FOR D1,D2,D3 C2 REQUIRED TO INSTALL SMOKE AND CO DETECTORS Item: 90 BLDG-Final REPT131 Run Id: 14739 NOTE: THIS PERMIT MUST BE POSTED ON JOBS►TE AT ALL TIMES ��;��^��:� :::::::f r:,�.�;����:��:� Town of Vail, Community Development, 75 South Frontage Road,Vail, Colorado 81657 p. 970.479.2139, f. 970.4792452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B13-0201 Project #: PRJ13-0230 Job Address: 2875 MANNS RANCH RD VAIL Applied.....: 05/30/2013 Location......: BOOTH CREEK TOWNHOUSES UNIT C2 Issued. . . : 05/31/2013 Parcel No....: 210103402008 OWNER RAUH-RYAN, LYNN- RYAN, TIMO 05/30/2013 497 KALMIA AVE BOULDER, CO 803041730 APPLICANT RECONSTRUCTION EXPERTS INC 05/30/2013 Phone: 303-783-2562 DAVE ORNBERG 5310 VIVIAN STREET ARVADA CO 80002 License: C000003273 CONTRACTOR RECONSTRUCTION EXPERTS INC 05/30/2013 Phone: 303-783-2562 DAVE ORNBERG 5310 VIVIAN STREET ARVADA CO 80002 License: C000003273 Description: WINDOW REPLACEMENTS FOR UNITS C2, D1, D2 AND D3 AT BOOTH CREEK TOWNHOUSES. Occupancy: R-2 Type Construction: V Valuation: $7,190.00 ��,r...,...,,.�..���t.,Y.,>=.,,,,_..-�.-�....�.��,�.-.�.��.�...,,,.,,.��.�._�� FEE SUMMARY .�.,+..,.���,,.-.....��.,.��,,�,r.�,�=.,.-.-.,.,......,.»-.,,.�,�.�.-..<..�,.., Building Permit-----------> $153.25 Bldg Plan Check----------> $99.61 Use Tax Fee-----------------------> $0.00 Electrical Permit---------> $0.00 Elec Plan Check-----------> $0.00 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $0.00 Mech Plan Check---------> $0.00 Additional Fees--------------------> $0.00 Plumbing Permit--------> $0.00 Plmb Plan Check---------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $5.00 TOTAL PERMIT FEES--------------> �257.86 Payments-------------------------------> 3257.86 BALANCE DUE------------------------> S0.00 >,t....��<,�......+,��.���.......,��..�.��.��,��.�....>....,»�����.��»,.,�...,.�,�......�.���„�.���..-.,�<......��...���......>„�»�.,,�-.....�...-...�.,...�...t....=,�-.�,������. DECIARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT �UR OFFICE FROM 8:00 AM - 4:00 PM. combination permit_012811 �mm�� 1_ ' F. -��f' �����W��3��'��•��� �.... tYfxkit:tw+tt#t#tt#tt�tt#*tttt#ttY'tt>*tttt�ttf��t*xfYrfwxxfttkkYt�t:t#fYtt:tYrtt*#ttww#�tttf:H'f*:tkttt#ttttt*ttt * � � *CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: 613-0201 Address: 2875 MANNS RANCH RD VAIL Owner: RAUH-RYAN, LYNN - RYAN, TIMOTHY Location: BOOTH CREEKTOWNHOUSES UNIT C2 �.,�,,..�.....,.�,,,t�,...,,�.,..>,�,»,���.,,�x�,.,tx..,�<.�.�.....,.-t..,,>.�....,,�...,,,,,„�.trx�.<t„t�.���..,,�..�.t.,t,,,,,.,.,,,,,��,�,,.,t��,,...,,.�„-.,....�,,,�,.:,.,...,,�,,.. combination permit_012811 �„�, � _....:: •�� �. ���� ��� z ��..��*������.�����������������**���<*����.*����**��«***�«����������*���***���*������*���**���*����*���*��*�***��***���*�*��****�*��****��*���**���* REQUIRED INSPECTIONS AND STATUSES Permit#: B13-0201 Address: 2875 MANNS RANCH RD VAIL Owner: RAUH-RYAN, LYNN - RYAN, TIMOTHY Location: BOOTH CREEK TOWNHOUSES UNIT C2 *���***���**���**���***��***��***���***��**��*�****�***�***,*�**��**��*****��**����***���**��**�*********�*********�****�*****��**���**�****��***��** Item: 00030 BLDG-Framing Item: 00090 BLDG-Final combination permit_012811 _.. _ _ . *�******************�***********�**********:�**********************************�x*********:x*** TOWN OF VAIL, COLORADO Statement ***************************:x******************************�=**************�********�********* Statement Number: R130000712 Amount: $257 .86 05/31/201304:25 PM Payment Method: Check Init: DR Notation: CK# 3037 RECONSTRUCTION EXPERTS ------------------------------------------------------------------ Permit No: B13-0201 Type: COMBINATION BLDG PERMIT Parcel No: 2101-034-0200-8 Site Address: 2875 MANNS RANCH RD VAIL Location: BOOTH CREEK TOWNHOUSES UNIT C2 Total Fees: $257.86 This Payment: $257.86 Total ALL Pmts: $257.86 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 153 .25 PF 00100003112300 PLAN CHECK FEES 99.61 WC 00100003112800 WILL CALL INSPECTION FEE 5.00 -------------------------------------------------------------------