HomeMy WebLinkAboutB13-0204 APPLICATION, RECEIPT AND PERMIT 02-10-2014 Inspection Request Reporting Page 5
4:00 pm Vail, CO - City Of 'OZ
Requested Inspect Date: Tuesday,February 11,22014
Site Address: 2875 MANNS RANCH RD VAIL
BOOTH CREEK TOWNHOUSES UNITS D3
A/P/D Information
Activity B13-0204 Type: COMBO Sub Type: AMF Status: ISSUED
Const Type Occupancy: Use: R-2 Insp Area:
Owner RAUH-RYAN, LYNN-RYAN,TIMOTHY
Contractor: RECONSTRUCTION EXPERTS INC Phone: 303-783-2562
Description: WINDOW REPLACEMENTS FOR UNITD3 AT BOOTH CREEK TOWNHOUSES.
Requested Inspection(s)
Item. 90 BLDG-Final Requested Time: 08:00 AM
Requestor Phone:
Comments follow up
Assigned To J D AGON Entered By: JMONDRAGON K
Action Time Exp:
Inspection History
Item: 30 BLDG-Framing
Item: 90 BLDG-Final
REPT131 Run Id: 14740
********************************************************************************************
TOWN OF VAIL, COLORADOCopy Reprinted on 05-31-2013 at 16:36:25 05/31/2013
Statement
********************************************************************************************
Statement Number: R130000715 Amount: $142.36 05/31/201304 :36 PM
Payment Method: Check Init: DR
Notation: CK# 3037
RECONSTRUCTION EXPERTS
-----------------------------------------------------------------------------
Permit No: B13-0204 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-034-0200-8
Site Address: 2875 MANNS RANCH RD VAIL
Location: BOOTH CREEK TOWNHOUSES UNITS D3
Total Fees: $142.36
This Payment: $142.36 Total ALL Pmts: $142.36
Balance: $0.00
********************************************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 BUILDING PERMIT FEES 83.25
PF 00100003112300 PLAN CHECK FEES 54 . 11
WC 00100003112800 WILL CALL INSPECTION FEE 5.00
-----------------------------------------------------------------------------
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
7M OF VAS.,.
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: 1313-0204
Project #: PRJ13-0230
Job Address: 2875 MANNS RANCH RD VAIL Applied.....: 05/30/2013
Location......: BOOTH CREEK TOWNHOUSES UNITS D3 Issued. . . : 05/31/2013
Parcel No....: 210103402008
OWNER RAUH-RYAN, LYNN - RYAN, TIMO 05/30/2013
497 KALMIA AVE
BOULDER, CO
803041730
APPLICANT RECONSTRUCTION EXPERTS INC 05/30/2013 Phone: 303-783-2562
DAVE ORNBERG
5310 VIVIAN STREET
ARVADA
CO 80002
License: C000003273
CONTRACTOR RECONSTRUCTION EXPERTS INC 05/30/2013 Phone: 303-783-2562
DAVE ORNBERG
5310 VIVIAN STREET
ARVADA
CO 80002
License: 0000003273
Description:
WINDOW REPLACEMENTS FOR UNITD3 AT BOOTH CREEK TOWNHOUSES.
Occupancy: R-2 Type Construction: V Valuation: $2,986.00
xxxwxxxxxxwxwwwwwwwwxwww}}rt}rt}rtx}rt}rt}xxxrtxwxw}}}}}w}ws.xwx.w}w}}x:wwwwwx�.�.xxxwwwx• FEE SUMMARY x.xxxxrtxxxxrtwxw.x...ww}.w}www}wwxxxwxxrtvarrxrtwxw.wws.s.s.www}wwwx}xxx}}}ww.xwww.}xx
Building Permit-----------> $83.25 Bldg Plan Check----------> $54.11 Use Tax Fee-----------------------> $0.00
Electrical Permit---------> $0.00 Elec Plan Check-----------> $0.00 Restuarant Plan Review--------> $0.00
Mechanical Permit------> $0.00 Mech Plan Check---------> $0.00 Additional Fees--------------------> $0.00
Plumbing Permit--------> $0.00 Plmb Plan Check---------> $0.00 Recreation Fee--------------------> $0.00
Investigation-----------------------> $0.00
Will Call------------------------------> $5.00
TOTAL PERMIT FEES--------------> $142.36
Payments-------------------------------> $142.36
BALANCE DUE------------------------> $0.00
}wrt+twf}}}}}.}rt}x}xxwlxfYYxxwtrtrtt.t}}}w}}}ww}}}rt1rlr�elrexrtxrtxxwwYwYrkrtxYex#fwwwwtfrRf444rtwwwrt}wrtrtle}xlrrtxxxxxtrYY.}tfwf.fftwxsift.rtrtrtxYr YrrtY.rtY.w/f#wrt}}wwwwwRw}wxxxxxxrtxrtxxRYr}xy.yy.xrtrtti.#xrt+e*xx+rtxw++
DECLARATIONS
I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
OR AT OUR OFFICE FROM 8:00 AM -4:00 PM.
combination permit-012811
TON OF OViAlL
R!!Rl ff!*R*fYtY#Y4#**fRfff!lfftflifRf Rl Rfl RRl RRY#Yi#44l f*R*R!!!!*RfYY#!!!!!!**f#f#RI RR!l RRRRYY44ffl f#RR!!!Yf#Y##44##*R!***f#!Yi#!!*#Rl RRRl Y!!##4f44Y!!R!!R*fff#!Y##**!***RRfffff!!!YY
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit#: B13-0204 Address: 2875 MANNS RANCH RD VAIL
Owner: RAUH-RYAN, LYNN - RYAN, TIMOTHY Location:
BOOTH CREEK TOWNHOUSES UNITS D3
I
combination permit-012811
OVAIL ..�'TOWN
REQUIRED INSPECTIONS AND STATUSES
Permit#: B13-0204 Address: 2875 MANNS RANCH RD VAIL
Owner: RAUH-RYAN, LYNN - RYAN, TIMOTHY Location:
BOOTH CREEK TOWNHOUSES UNITS D3
Item: 00030 BLDG-Framing
Item: 00090 BLDG-Final
combination permit-012811
Department of Community Development
0 75 South Frontage Road West
Vail, CO 81657
TOWN OF VA I L Tel: 970-479-2128
Community Development www.vailgov.com
Department Development Review Coordinator
WINDOW REPLACEMENT PERMIT APPLICATION
(This permit is applicable to one and two family dwelling units only)
(Permit fee = standard building fees and design review fee)
Project Information Type of Building:
Owner Name: WILLIAM C. BURKE 2006 LIVING TRUST
One Family( )Two Family(Duplex) ( ) Multi-Family( v )
Parcel#: 2101-034-02-013
(For Parcel#,contact Eagle County Assessors Office at(970-328-8640 or visit Submittal Requirements:
www.eaglecounty.us/patie) • Joint Property Owner Written Approval Letter(duplex or
multi-family HOA)
Project Street Address: . Two(2)plan sets indicating:
2875 Manns Ranch Road D3 • -Floor plans showing window location(s)and eleva-
tions(window schedule may be substituted for eleva-
tions)(Street)
Contractor Information
• Emergency egress requirements in bedrooms
• Size of windows and openings
Business Name: Reconstruction Experts • ' U-Value of windows
• Material, cut sheets and color of windows(must
Business Address: 5310 Vivian St match style and color of building)
City Arvada State: co Zip: 80002
• - Full view elevation photos of all sides of building
Detailed Scope and Location of Work. 4 Window Replacement
Contact Name: Matt Bribacn
See Attached
Contact Phone: 970-409-0161
Contact E-Mall: mbribach @reconstructionexperts.net
(use additional sheet if necessary)
Applicant Information(fill in if different from contractor)
Valuation
Applicant Name: Work Included Plans Included of Work
pp ( )Yes (( )No (( )Yes h )No
Applicant Phone: Electrical
Applicant E-Mail: Mechanical ( ��Yes ((-,No ((-)Yes (-)No
I hereby acknowledge that I have read this application, filled out in Plumbing (-)Yes ('--)No ((-)Yes
full the information required,completed an accurate site plan, and
state that all the information as required is correct. I agree to Building ( )Yes ( No ((-)Yes (-)No 2986
comply with the information and site plan, to comply with all Town
ordinances and state laws, and to build this structure according to Value of all work being performed: $ 2986
the town's zoning and subdivision codes, design review approval, (value based on IBC Section 109.3&IRC Section 108.3)
International Building and Residential Codes and other ordinances
of the Town applicable thereto. Date Received: VnMWAY Owner/Owner's Representative Signature Required(typed or digital signature) 2 9 2013
Checking this box indicates you are electronically signing
this application and agree to the above statement. N OF Vail
For Office Use Only: Project#: �QS 1 3 "O a 3 Q
Fee Paid:
Received From: Building Permit#:Bl
Cash Check#
CC: Visa/MC Last 4 CC# Auth#:
Lot#: Block# Subdivision:
12-Sep 20
TOWN OF VAIL
JOINT PROPERTY OWNER
WRITTEN APPROVAL LETTER
The applicant must submit written joint property owner approval for applications affecting shared ownership properties
such as duplex, condominium, and multi-tenant buildings. This form, or similar written correspondence, must be com-
pleted by the adjoining duplex unit owner or the authorized agent of the home owner's association in the case of a con-
dominium or multi-tenant building. All completed forms must be submitted with the applicants completed application.
I, (print name) Pam Stenmark , a joint owner, or authority of the association,
of property located at 2875 Manns Ranch Road, Unit D3- Vail, Colorado 81657 , provide this letter as written
approval of the plans dated which have been submitted to the
Town of Vail Community Development Department for the proposed improvements to be completed at the address not-
ed above. I understand that the proposed improvements include:
Replacement of 4 Windows
I understand that modifications may be made to the plans over the course of the review process to ensure compliance
with the Town's applicable codes and regulations; and that it is the sole responsibility of the applicant to keep the joint
property owner apprised of any changes and ensure that the changes are acceptable and appropriate. Submittal of an
application results in the applicant agreeing to this statement.
Signature Date
TA*-1 C.A S rez N cL4 0.�►c
Print Name
i
n tte
y
a
. t (
t
i
AdIwi
a gip"app }
4. '��� f0�' '��py'k.,-5'c�,mf 5': h �6 sad k. > •3
' �� T QUi¢pr �: E2:F''.. Y "'� y.►�eawa. , .. �_ •An
_ Y �
r. N
a
Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number:4502983
Line# Location: Attributes
Ve ux - I udes Step Flashing R.O. Item Price city Ext'd Price
3 WNW
Line# Location: Attributes
e ux ounted Laminated/Aluminum Includes Item Price Qty Exrd Price
2 4MM 2 4000
Line# Location: Attributes
230 D3-Entry ProLine, Casement Right,25 X 53, Brown,49116° Item Price Qty Ext'd Price
1:2553 Right Casement
PK# Frame Size:25 X 53
559 General Information: Clad
Exterior Color/Finish:Standard EnduraClad,Brown
Interior Color/Finish: Unfinished Interior
- Glass: Insulated Tempered Low E SunDefense High Altitude
Viewed From Exterior Hardware Options:Standard Roto Operator, Champagne
Rough Opening: 2'1 3/4"X 4'5 3/4' Screen:Full Screen,Champagne,InView
Grille:
Final Wall Depth: 4-9/16" Wrapping Information: Foldout Fins,Factory Applied,49116"Standard 4-sided Jamb Extension, Factory Applied,Perimeter Length=156",Glazing Pressure
=205.
For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at www.pelia.com
Printed on 4/3012013 Detailed Proposal Page 25 of 35
Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number:4502983
Line# Location: Attributes
235 D3-Kitchen ProLine, Casement Left, 25 X 35, Brown, 49116" Item Price Qty Exrd Price
,�■s 1 "Nib
_ g 1:2535 Left Casement
r + PK# Frame Size:25 X 35
559 General Information: Clad
Exterior Color/Finish:Standard EnduraClad,Brown
(; Interior Color/Finish:Unfinished Interior
Glass:Insulated Low E SunDefense High Altitude
Viewed From Exterior Hardware Options:Standard Roto Operator, Champagne
Rough Opening: 2'1 3/4"X 2'11 3/4' Screen:Full Screen,Champagne,InView
Grille:
Final Wall Depth: 4-9/16' Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length=120",Glazing Pressure
=95.
For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at www.pelia.com
Printed on 4/30/2013 Detailed Proposal Page 26 of 35
Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number:4502983
Llne ll Location: Attributes
240 D3-Loft ProLine, 4-Wide Casement, 97 X 41.5, Brown, 4.9116" Item Price City Ext'd Price
� 1 �
�, .� 1:Non-Standard Size Fixed Casement
., r PK# Frame Size:22 X 41 1/2
559 General Information: Clad
..�..5 Exterior Color I Finish:Standard EnduraClad.Brown
Interior Color 1 Finish: Unfinished Interior
Glass:Insulated Low E SunDefense High Altitude
Viewed From Exterior Grille:
Rough Opening: 8'13/4'X T6 1/4' Vertical Mull 1:FactoryMull,Standard(Vertical Factory)(0')
2:Non-Standard Size Left Casement
Final Wall Depth: 4-9/16' Frame Size:26 112 X 41 1/2
General Information: Clad
Exterior Color 1 Finish:Standard EnduraClad,Brown
Interior Color I Finish:Unfinished Interior
Glass:Insulated Low E SunDefense High Altitude
Hardware Options:Side Pivot Hardware, Champagne
Screen: Full Screen,Champagne,InView
Grille:
Vertical Mull 2:FactoryMull,Standard(Vertical Factory)(0')
3:Non-Standard Size Right Casement
Frame Size:26 112 X 41 1/2
General Information: Clad
Exterior Color/Finish:Standard EnduraClad.Brown
Interior Color I Finish: Unfinished Interior
Glass: Insulated Low E SunDefense High Altitude
Hardware Options:Standard Roto Operator, Champagne
Screen:Full Screen,Champagne,InView
Grille:
Vertical Mull 3:FactoryMull,Standard(Vertical Factory)(0')
4: Non-Standard Size Fixed Casement
Frame Size:22 X 41 1/2
General Information: Clad
Exterior Color/Finish:Standard EnduraClad,Brown
Interior Color/Finish:Unfinished Interior
Glass:Insulated Low E SunDefense High Altitude
Grille:
Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length=277",Glazing Pressure
=75.
For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at www.pelia.com
Printed on 4/30/2013 Detailed Proposal Page 27 of 35
Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number:4502983
Une 0 Location: Attributes
245 D3-Bath ProLine, 2-Wide Casement, 48.5 X 41.5, Brown,4-9116" item Price Qty Ext'd Price
1: Non-Standard Size Left Casement
PK# Frame Size:24 1/4 X 41 1/2
559
General Information: Clad
fExterior Color/Finish:Standard EnduraClad. Brown
_ Interior Color/Finish:Unfinished Interior
Glass: Insulated Tempered Low E SunDefense High Altitude
Viewed From Exterior Hardware Options:Standard Roto Operator. Champagne
Rough Opening: 4'11/4"X T6 1/4" Screen:Full Screen,Champagne,InView
Grille:
Final Wall Depth: 4-9/16' Vertical Mull 1:FactoryMull,Standard(Vertical Factory)(0')
2:Non-Standard Size Right Casement
Frame Size:24 1/4 X 41 1/2
General Information: Clad
Exterior Color/Finish:Standard EnduraClad, Brown
Interior Color/Finish:Unfinished Interior
Glass: Insulated Tempered Low E SunDefense High Altitude
Hardware Options:Standard Roto Operator, Champagne
Screen:Full Screen,Champagne,InView
Grille:
Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied, Perimeter Length= 180",Glazing Pressure
=205.
Line I Location: Attributes
ProLine, Sliding Contemporary Door Fixed I Vent, 7 1.5, Brown, 4-9116" Item Price Qty Ext'd Price
1:7282 Fixed/Vent Sliding Contempor r
# Frame Size:71 1/4 X 81 1/2
559 General Information:
' r Color/ :Standard EnduraClad,Brown
f Interior Finish: Unfinished Interior
s: Insulated ed Low E SunDefense High Altitude
Viewed From Exterior Hardware Options:Champ ootbolt,Handle Included,Handle Included,Champagne
Rough Opening: 10' Screen:Sliding Screen,Wood Inten wn Exterior,Champagne,Champagne,InView
Grille:
Final epth: 4-9/16' Wrapping Information: Foldout Fins,Factory Applie "Factory Applied,Perimeter Length=306",Glazing Pressure=175.
For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at www.pella.com
Printed on 4/30/2013 Detailed Proposal Page 28 of 35
i
d
F 4
C)Q7YA
N
ARCHITECT
w
i GLAZING OPTIONS SERIES SERIES PROLINE FIXED
Clear Irissulatlng Glass
Argon-MW,Low-E Insulating
Glass* • j •
•
Dual Glazing with Between-
the-Glass Options
Triple Glazing with Between_
the-Glass Options •
Laminated Glass •
Impact Resistant Glass .
Tinted Glass
Reflective Glass '
Spandrel glass or panels
Nigh-attitude Low-E kwullii&V glass does
argon gas.
D•
PERFORMANCE
..----� NFRC U-value Total Untt 0. -0.51 011.23-0.49
n Pressure*( -75 0.29-0.5o 0.29-0.5 3
50-70 30-50 20-90
Water a Test Pre55Urc(psfl - 113 75- 105
45-75 30- 135
Water Penetration O 7.5 psf O 10.5
pst none O 7.5 psf Wort!O 15
Air Inflitration(@ 1.57 psf) 0.05 dm 0.05 cfm
0.05 cfm 0.05 cfm
*Performance class and grade rating 4nd related hallmark certification apply to single units oni w/th
options and not the combined or composite units. Y appropriate Qlass
3For 48'x 48"windows
CENTER GLASS
• .
Winter NFRC U-value 0.25-0.51 0.16-0.50
0.25-0.51 0.25-0.51
Solar Neat Caa81 Coefficient
0.32-0. .26 0.79
0.41-0.79 0.32-0.79
Shading CceRtcient .37- 1 0 1-0.91;`
0.47 0.91 0.37 -0.91
96 UV Transmission 63 /
LBL Fading Damage' 16-62 7-62 0. -0.64 0.15 0. S
%Visible Light Transmission 0.33-0-64 0.18-0.64
33- 72-83 40-83
'Developed by Lawrence Berkeley La t�_e L.BL d amage funct n Is a better predictor of fading damage than UV
transmission.Lower values indlcate less fading UalThis value does not nsider visible light.)
,!SOUND
TRANSMISSION
PERFORMANCE'
STC Rating
27-36
33-38 28-29 28-36
OITC Rating 22-32
26-31 23-26 24-_32
SPerformance based on standard glass options.