Loading...
HomeMy WebLinkAboutB13-0204 APPLICATION, RECEIPT AND PERMIT 02-10-2014 Inspection Request Reporting Page 5 4:00 pm Vail, CO - City Of 'OZ Requested Inspect Date: Tuesday,February 11,22014 Site Address: 2875 MANNS RANCH RD VAIL BOOTH CREEK TOWNHOUSES UNITS D3 A/P/D Information Activity B13-0204 Type: COMBO Sub Type: AMF Status: ISSUED Const Type Occupancy: Use: R-2 Insp Area: Owner RAUH-RYAN, LYNN-RYAN,TIMOTHY Contractor: RECONSTRUCTION EXPERTS INC Phone: 303-783-2562 Description: WINDOW REPLACEMENTS FOR UNITD3 AT BOOTH CREEK TOWNHOUSES. Requested Inspection(s) Item. 90 BLDG-Final Requested Time: 08:00 AM Requestor Phone: Comments follow up Assigned To J D AGON Entered By: JMONDRAGON K Action Time Exp: Inspection History Item: 30 BLDG-Framing Item: 90 BLDG-Final REPT131 Run Id: 14740 ******************************************************************************************** TOWN OF VAIL, COLORADOCopy Reprinted on 05-31-2013 at 16:36:25 05/31/2013 Statement ******************************************************************************************** Statement Number: R130000715 Amount: $142.36 05/31/201304 :36 PM Payment Method: Check Init: DR Notation: CK# 3037 RECONSTRUCTION EXPERTS ----------------------------------------------------------------------------- Permit No: B13-0204 Type: COMBINATION BLDG PERMIT Parcel No: 2101-034-0200-8 Site Address: 2875 MANNS RANCH RD VAIL Location: BOOTH CREEK TOWNHOUSES UNITS D3 Total Fees: $142.36 This Payment: $142.36 Total ALL Pmts: $142.36 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 83.25 PF 00100003112300 PLAN CHECK FEES 54 . 11 WC 00100003112800 WILL CALL INSPECTION FEE 5.00 ----------------------------------------------------------------------------- NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES 7M OF VAS.,. Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: 1313-0204 Project #: PRJ13-0230 Job Address: 2875 MANNS RANCH RD VAIL Applied.....: 05/30/2013 Location......: BOOTH CREEK TOWNHOUSES UNITS D3 Issued. . . : 05/31/2013 Parcel No....: 210103402008 OWNER RAUH-RYAN, LYNN - RYAN, TIMO 05/30/2013 497 KALMIA AVE BOULDER, CO 803041730 APPLICANT RECONSTRUCTION EXPERTS INC 05/30/2013 Phone: 303-783-2562 DAVE ORNBERG 5310 VIVIAN STREET ARVADA CO 80002 License: C000003273 CONTRACTOR RECONSTRUCTION EXPERTS INC 05/30/2013 Phone: 303-783-2562 DAVE ORNBERG 5310 VIVIAN STREET ARVADA CO 80002 License: 0000003273 Description: WINDOW REPLACEMENTS FOR UNITD3 AT BOOTH CREEK TOWNHOUSES. Occupancy: R-2 Type Construction: V Valuation: $2,986.00 xxxwxxxxxxwxwwwwwwwwxwww}}rt}rt}rtx}rt}rt}xxxrtxwxw}}}}}w}ws.xwx.w}w}}x:wwwwwx�.�.xxxwwwx• FEE SUMMARY x.xxxxrtxxxxrtwxw.x...ww}.w}www}wwxxxwxxrtvarrxrtwxw.wws.s.s.www}wwwx}xxx}}}ww.xwww.}xx Building Permit-----------> $83.25 Bldg Plan Check----------> $54.11 Use Tax Fee-----------------------> $0.00 Electrical Permit---------> $0.00 Elec Plan Check-----------> $0.00 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $0.00 Mech Plan Check---------> $0.00 Additional Fees--------------------> $0.00 Plumbing Permit--------> $0.00 Plmb Plan Check---------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $5.00 TOTAL PERMIT FEES--------------> $142.36 Payments-------------------------------> $142.36 BALANCE DUE------------------------> $0.00 }wrt+twf}}}}}.}rt}x}xxwlxfYYxxwtrtrtt.t}}}w}}}ww}}}rt1rlr�elrexrtxrtxxwwYwYrkrtxYex#fwwwwtfrRf444rtwwwrt}wrtrtle}xlrrtxxxxxtrYY.}tfwf.fftwxsift.rtrtrtxYr YrrtY.rtY.w/f#wrt}}wwwwwRw}wxxxxxxrtxrtxxRYr}xy.yy.xrtrtti.#xrt+e*xx+rtxw++ DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4:00 PM. combination permit-012811 TON OF OViAlL R!!Rl ff!*R*fYtY#Y4#**fRfff!lfftflifRf Rl Rfl RRl RRY#Yi#44l f*R*R!!!!*RfYY#!!!!!!**f#f#RI RR!l RRRRYY44ffl f#RR!!!Yf#Y##44##*R!***f#!Yi#!!*#Rl RRRl Y!!##4f44Y!!R!!R*fff#!Y##**!***RRfffff!!!YY CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: B13-0204 Address: 2875 MANNS RANCH RD VAIL Owner: RAUH-RYAN, LYNN - RYAN, TIMOTHY Location: BOOTH CREEK TOWNHOUSES UNITS D3 I combination permit-012811 OVAIL ..�'TOWN REQUIRED INSPECTIONS AND STATUSES Permit#: B13-0204 Address: 2875 MANNS RANCH RD VAIL Owner: RAUH-RYAN, LYNN - RYAN, TIMOTHY Location: BOOTH CREEK TOWNHOUSES UNITS D3 Item: 00030 BLDG-Framing Item: 00090 BLDG-Final combination permit-012811 Department of Community Development 0 75 South Frontage Road West Vail, CO 81657 TOWN OF VA I L Tel: 970-479-2128 Community Development www.vailgov.com Department Development Review Coordinator WINDOW REPLACEMENT PERMIT APPLICATION (This permit is applicable to one and two family dwelling units only) (Permit fee = standard building fees and design review fee) Project Information Type of Building: Owner Name: WILLIAM C. BURKE 2006 LIVING TRUST One Family( )Two Family(Duplex) ( ) Multi-Family( v ) Parcel#: 2101-034-02-013 (For Parcel#,contact Eagle County Assessors Office at(970-328-8640 or visit Submittal Requirements: www.eaglecounty.us/patie) • Joint Property Owner Written Approval Letter(duplex or multi-family HOA) Project Street Address: . Two(2)plan sets indicating: 2875 Manns Ranch Road D3 • -Floor plans showing window location(s)and eleva- tions(window schedule may be substituted for eleva- tions)(Street) Contractor Information • Emergency egress requirements in bedrooms • Size of windows and openings Business Name: Reconstruction Experts • ' U-Value of windows • Material, cut sheets and color of windows(must Business Address: 5310 Vivian St match style and color of building) City Arvada State: co Zip: 80002 • - Full view elevation photos of all sides of building Detailed Scope and Location of Work. 4 Window Replacement Contact Name: Matt Bribacn See Attached Contact Phone: 970-409-0161 Contact E-Mall: mbribach @reconstructionexperts.net (use additional sheet if necessary) Applicant Information(fill in if different from contractor) Valuation Applicant Name: Work Included Plans Included of Work pp ( )Yes (( )No (( )Yes h )No Applicant Phone: Electrical Applicant E-Mail: Mechanical ( ��Yes ((-,No ((-)Yes (-)No I hereby acknowledge that I have read this application, filled out in Plumbing (-)Yes ('--)No ((-)Yes full the information required,completed an accurate site plan, and state that all the information as required is correct. I agree to Building ( )Yes ( No ((-)Yes (-)No 2986 comply with the information and site plan, to comply with all Town ordinances and state laws, and to build this structure according to Value of all work being performed: $ 2986 the town's zoning and subdivision codes, design review approval, (value based on IBC Section 109.3&IRC Section 108.3) International Building and Residential Codes and other ordinances of the Town applicable thereto. Date Received: VnMWAY Owner/Owner's Representative Signature Required(typed or digital signature) 2 9 2013 Checking this box indicates you are electronically signing this application and agree to the above statement. N OF Vail For Office Use Only: Project#: �QS 1 3 "O a 3 Q Fee Paid: Received From: Building Permit#:Bl Cash Check# CC: Visa/MC Last 4 CC# Auth#: Lot#: Block# Subdivision: 12-Sep 20 TOWN OF VAIL JOINT PROPERTY OWNER WRITTEN APPROVAL LETTER The applicant must submit written joint property owner approval for applications affecting shared ownership properties such as duplex, condominium, and multi-tenant buildings. This form, or similar written correspondence, must be com- pleted by the adjoining duplex unit owner or the authorized agent of the home owner's association in the case of a con- dominium or multi-tenant building. All completed forms must be submitted with the applicants completed application. I, (print name) Pam Stenmark , a joint owner, or authority of the association, of property located at 2875 Manns Ranch Road, Unit D3- Vail, Colorado 81657 , provide this letter as written approval of the plans dated which have been submitted to the Town of Vail Community Development Department for the proposed improvements to be completed at the address not- ed above. I understand that the proposed improvements include: Replacement of 4 Windows I understand that modifications may be made to the plans over the course of the review process to ensure compliance with the Town's applicable codes and regulations; and that it is the sole responsibility of the applicant to keep the joint property owner apprised of any changes and ensure that the changes are acceptable and appropriate. Submittal of an application results in the applicant agreeing to this statement. Signature Date TA*-1 C.A S rez N cL4 0.�►c Print Name i n tte y a . t ( t i AdIwi a gip"app } 4. '��� f0�' '��py'k.,-5'c�,mf 5': h �6 sad k. > •3 ' �� T QUi¢pr �: E2:F''.. Y "'� y.►�eawa. , .. �_ •An _ Y � r. N a Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number:4502983 Line# Location: Attributes Ve ux - I udes Step Flashing R.O. Item Price city Ext'd Price 3 WNW Line# Location: Attributes e ux ounted Laminated/Aluminum Includes Item Price Qty Exrd Price 2 4MM 2 4000 Line# Location: Attributes 230 D3-Entry ProLine, Casement Right,25 X 53, Brown,49116° Item Price Qty Ext'd Price 1:2553 Right Casement PK# Frame Size:25 X 53 559 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish: Unfinished Interior - Glass: Insulated Tempered Low E SunDefense High Altitude Viewed From Exterior Hardware Options:Standard Roto Operator, Champagne Rough Opening: 2'1 3/4"X 4'5 3/4' Screen:Full Screen,Champagne,InView Grille: Final Wall Depth: 4-9/16" Wrapping Information: Foldout Fins,Factory Applied,49116"Standard 4-sided Jamb Extension, Factory Applied,Perimeter Length=156",Glazing Pressure =205. For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at www.pelia.com Printed on 4/3012013 Detailed Proposal Page 25 of 35 Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number:4502983 Line# Location: Attributes 235 D3-Kitchen ProLine, Casement Left, 25 X 35, Brown, 49116" Item Price Qty Exrd Price ,�■s 1 "Nib _ g 1:2535 Left Casement r + PK# Frame Size:25 X 35 559 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown (; Interior Color/Finish:Unfinished Interior Glass:Insulated Low E SunDefense High Altitude Viewed From Exterior Hardware Options:Standard Roto Operator, Champagne Rough Opening: 2'1 3/4"X 2'11 3/4' Screen:Full Screen,Champagne,InView Grille: Final Wall Depth: 4-9/16' Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length=120",Glazing Pressure =95. For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at www.pelia.com Printed on 4/30/2013 Detailed Proposal Page 26 of 35 Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number:4502983 Llne ll Location: Attributes 240 D3-Loft ProLine, 4-Wide Casement, 97 X 41.5, Brown, 4.9116" Item Price City Ext'd Price � 1 � �, .� 1:Non-Standard Size Fixed Casement ., r PK# Frame Size:22 X 41 1/2 559 General Information: Clad ..�..5 Exterior Color I Finish:Standard EnduraClad.Brown Interior Color 1 Finish: Unfinished Interior Glass:Insulated Low E SunDefense High Altitude Viewed From Exterior Grille: Rough Opening: 8'13/4'X T6 1/4' Vertical Mull 1:FactoryMull,Standard(Vertical Factory)(0') 2:Non-Standard Size Left Casement Final Wall Depth: 4-9/16' Frame Size:26 112 X 41 1/2 General Information: Clad Exterior Color 1 Finish:Standard EnduraClad,Brown Interior Color I Finish:Unfinished Interior Glass:Insulated Low E SunDefense High Altitude Hardware Options:Side Pivot Hardware, Champagne Screen: Full Screen,Champagne,InView Grille: Vertical Mull 2:FactoryMull,Standard(Vertical Factory)(0') 3:Non-Standard Size Right Casement Frame Size:26 112 X 41 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad.Brown Interior Color I Finish: Unfinished Interior Glass: Insulated Low E SunDefense High Altitude Hardware Options:Standard Roto Operator, Champagne Screen:Full Screen,Champagne,InView Grille: Vertical Mull 3:FactoryMull,Standard(Vertical Factory)(0') 4: Non-Standard Size Fixed Casement Frame Size:22 X 41 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad,Brown Interior Color/Finish:Unfinished Interior Glass:Insulated Low E SunDefense High Altitude Grille: Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied,Perimeter Length=277",Glazing Pressure =75. For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at www.pelia.com Printed on 4/30/2013 Detailed Proposal Page 27 of 35 Customer: Reconstruction Experts Project Name: Booth Creek Townhomes Quote Number:4502983 Une 0 Location: Attributes 245 D3-Bath ProLine, 2-Wide Casement, 48.5 X 41.5, Brown,4-9116" item Price Qty Ext'd Price 1: Non-Standard Size Left Casement PK# Frame Size:24 1/4 X 41 1/2 559 General Information: Clad fExterior Color/Finish:Standard EnduraClad. Brown _ Interior Color/Finish:Unfinished Interior Glass: Insulated Tempered Low E SunDefense High Altitude Viewed From Exterior Hardware Options:Standard Roto Operator. Champagne Rough Opening: 4'11/4"X T6 1/4" Screen:Full Screen,Champagne,InView Grille: Final Wall Depth: 4-9/16' Vertical Mull 1:FactoryMull,Standard(Vertical Factory)(0') 2:Non-Standard Size Right Casement Frame Size:24 1/4 X 41 1/2 General Information: Clad Exterior Color/Finish:Standard EnduraClad, Brown Interior Color/Finish:Unfinished Interior Glass: Insulated Tempered Low E SunDefense High Altitude Hardware Options:Standard Roto Operator, Champagne Screen:Full Screen,Champagne,InView Grille: Wrapping Information:Foldout Fins,Factory Applied,4-9/16"Standard 4-sided Jamb Extension,Factory Applied, Perimeter Length= 180",Glazing Pressure =205. Line I Location: Attributes ProLine, Sliding Contemporary Door Fixed I Vent, 7 1.5, Brown, 4-9116" Item Price Qty Ext'd Price 1:7282 Fixed/Vent Sliding Contempor r # Frame Size:71 1/4 X 81 1/2 559 General Information: ' r Color/ :Standard EnduraClad,Brown f Interior Finish: Unfinished Interior s: Insulated ed Low E SunDefense High Altitude Viewed From Exterior Hardware Options:Champ ootbolt,Handle Included,Handle Included,Champagne Rough Opening: 10' Screen:Sliding Screen,Wood Inten wn Exterior,Champagne,Champagne,InView Grille: Final epth: 4-9/16' Wrapping Information: Foldout Fins,Factory Applie "Factory Applied,Perimeter Length=306",Glazing Pressure=175. For more information regarding the finishing, maintenance, service and warranty of all Pella®products, visit the Pella®website at www.pella.com Printed on 4/30/2013 Detailed Proposal Page 28 of 35 i d F 4 C)Q7YA N ARCHITECT w i GLAZING OPTIONS SERIES SERIES PROLINE FIXED Clear Irissulatlng Glass Argon-MW,Low-E Insulating Glass* • j • • Dual Glazing with Between- the-Glass Options Triple Glazing with Between_ the-Glass Options • Laminated Glass • Impact Resistant Glass . Tinted Glass Reflective Glass ' Spandrel glass or panels Nigh-attitude Low-E kwullii&V glass does argon gas. D• PERFORMANCE ..----� NFRC U-value Total Untt 0. -0.51 011.23-0.49 n Pressure*( -75 0.29-0.5o 0.29-0.5 3 50-70 30-50 20-90 Water a Test Pre55Urc(psfl - 113 75- 105 45-75 30- 135 Water Penetration O 7.5 psf O 10.5 pst none O 7.5 psf Wort!O 15 Air Inflitration(@ 1.57 psf) 0.05 dm 0.05 cfm 0.05 cfm 0.05 cfm *Performance class and grade rating 4nd related hallmark certification apply to single units oni w/th options and not the combined or composite units. Y appropriate Qlass 3For 48'x 48"windows CENTER GLASS • . Winter NFRC U-value 0.25-0.51 0.16-0.50 0.25-0.51 0.25-0.51 Solar Neat Caa81 Coefficient 0.32-0. .26 0.79 0.41-0.79 0.32-0.79 Shading CceRtcient .37- 1 0 1-0.91;` 0.47 0.91 0.37 -0.91 96 UV Transmission 63 / LBL Fading Damage' 16-62 7-62 0. -0.64 0.15 0. S %Visible Light Transmission 0.33-0-64 0.18-0.64 33- 72-83 40-83 'Developed by Lawrence Berkeley La t�_e L.BL d amage funct n Is a better predictor of fading damage than UV transmission.Lower values indlcate less fading UalThis value does not nsider visible light.) ,!SOUND TRANSMISSION PERFORMANCE' STC Rating 27-36 33-38 28-29 28-36 OITC Rating 22-32 26-31 23-26 24-_32 SPerformance based on standard glass options.