Loading...
HomeMy WebLinkAboutB13-0181 PLANS APPROVEDTV WV WV WV WV X 8210.9' X 8219.8' X 8186.1' PEAK PEAK PEAK X 8184.3' PEAK X (8210.1') X (8210.1') X (8201.2')X X (8201.1') (8201.0') X (8210.1') DECK DECK DECK DECK (B225, P203) (RN 911289) 10' 1.4' 1.1' 1.1' 1.0' 0.6' 1.0' 1.2'1.2' 1.2' 1.2' 1.2' 1.2' 0. 8' 0. 4' 0.4' 0.4' 0.5' 1.0' 1.0' 1.0' 1.0' 1.0' 1.0' 0.6' 0. 6' 0. 6' 0. 6' 1.0' 1.0' 1.0' 1.0' 1.0'1.0' 0.5' 0. 5' 0.5' 0. 6' 0. 6' 0.4' 0. 3' 0.4' 0.4' 0. 3' 0.5' 0.3'0.3' 0. 4' 0. 3' 0. 5' 0. 3' (2) 0. 4' (2) 0. 5' 11.0' 5.9' 58.3' 24.5' 2.1'8.5' 2.1' 8.5' 23.1' 11.6' 8.4' 26.9' 6.1' 4.0' 16.7' 4.9' 9. 3 ' 25.6' 4. 6 ' 16.0' 18.7' 11.5' 4.0' 16.0' 4.7' 25.8' 30.5' 2.0' 2 . 9 ' 2.1' 2.0' G O R E C R E E K D R I V E (40' R.O.W.) LOT K BLOCK 5A VILLA VALHALLA CONDOMINIUMS FOUNDERS PARKING H A N S O N R A N C H R O A D (40' R.O.W.) GARAGE VAIL VILLAGE FIFTH FILING N 68°3 7'00" E 44.73' S 06°00'09" W 142.49' S 70°00'00" W 35.00' N 07°50'41" W 133.24' =24°37'08" R=180.77' L=77.67' T=39.45' CLEN=77.08' BRG=N 80°55'34" E =25°06'04" R=120.17' L=52.65' T=26.75' CLEN=52.23' BRG=S 82°33'02" 8 1 8 0 8 1 8 0 84 86 82 78 76 74 76 78 82 X8183.0' X 8174.3' PAVER PARKING UTILITY & DRAINAGE EASEMENT (R.N. 102538) ORNAMENTAL BLDG. PROJECTION (TYP.) FND. #4 REBAR & ALUMINUM CAP LS. 16827 FND. PLAIN #5 REBAR SHED FLOWLINE CONC. PAN EDGE OF ASPHALT EDGE OF BUILDING STONE CURB CURB & GUTTER CONC. WALK EDGE OF POOL DECK PARKING BOLLARDS (TYPICAL) PAVER PARKING 0.3124 ACRES 360 SPLIT RAIL FENCE CURB & GUTTER EDGE OF PLOWED ROAD SPLIT RAIL FENCE BENCH BENCH LIGHT (TYP) ELEC TRANS CONC. WALKCONC. WALK CONC. WALK STONE WALL CONC. WALK STEEL FENCE SPRINKLER VALVE (TYP.) STEEL FENCE CURB & GUTTER FIRE HYD TV PED STORM GRATE GAS VALVE WATER VALVE (TYP) STORM GRATE SEWER MH X 8191.2' TOP OF WALL X 8187.0' TOP OF WALL ELEC TRANS ELEC JUNCTION BOX X 8176.6' TOP OF WALL WALL STONE PIERS WOOD TIE WALL TV PED GAS METER PAVER WALK STONE VENEER WALL (TYP) WOOD TIE WALL ROOF EAVE (TYP) ROOF EAVE (TYP) EDGE OF BUILDING FND. #4 REBAR & ALUMINUM CAP LS. 2 (SEE NOTE 9, R.N. 200732077) 73.7 73.4 72.9 73.1 73.0 73.4 73.1 73.1 73.0 73.3 73.6 73.4 73.4 73.4 73.9 74.3 74.4 74.9 75.4 77.0 77.3 76.4 77.0 78.5 80.3 80.8 77.1 77.1 82.9 83.4 82.7 82.4 82.7 82.7 82.4 85.4 85.5 85.8 86.1 87.4 86.9 87.1 86.5 85.7 86.6 85.3 82.9 83.2 82.9 81.7 77.3 77.2 79.1 80.9 74.4 74.3 74.2 74.8 74.4 74.2 73.6 74.4 76.0 74.3 74.3 74.3 86.4 76.2 SITE Ro o m n a m e 10 1 EL E V A T I O N A1 0 1 1 SI M 10 0 ' - 0 " SP O T E L E V A T I O N 1 A1 0 1 SI M DE T A I L N U M B E R SH E E T W H E R E S H O W N SE C T I O N L E T T E R SH E E T W H E R E S H O W N DE T A I L D E S I G N A T O R BU I L D I N G S E C T I O N D E S I G N A T O R 1 10 1 DO O R D E S I G N A T O R 1i WI N D O W D E S I G N A T O R 0 GR I D L I N E 1i WA L L T Y P E 1 RE V I S E D A R E A OF D R A W I N G LE V E L I N D I C A T O R NA M E IN T E R I O R E L E V A T I O N D E S I G N A T O R A6 0 1 1 EL E V A T I O N N U M B E R SH E E T N U M B E R DO O R N U M B E R RO O M N U M B E R RO O M N U M B E R EX T E R I O R E L E V A T I O N D E S I G N A T O R A3 0 1 1 EL E V A T I O N N U M B E R SH E E T N U M B E R 00 0 0 0 0 CO N S T R U C T I O N SP E C I F I C A T I O N I N S T I T U T E SE C T I O N N U M B E R - R E F E R T O PR O J E C T M A N U A L F O R PR O D U C T S P E C I F I C A T I O N 4' - 5 " FA C E O F S T R U C T U R E T O FA C E O F S T R U C T U R E O R EX I S T I N G F I N I S H LE G E N D SI T E C O V E R A G E ( U N C H A N G E D ) LA N D S C A P E C O V E R A G E ( U N C H A N G E D ) ISSUE RECORD 1650 Fallridge Road, Suite C-1 Vail, CO 81657 f.(970) 476-4901 p.(970)476-6342COMMON AREA IMPROVEMENTS 384 GORE CREEK DRIVE VAI, CO A0.01COVER &PROJECT INFOVILLA VALHALLA - VAIL Project #121006 MAY 3013 CD'SDRAWING INDEX VI L L A V A L H A L L A - U N I T S 3 / 4 / 8 I M P R O V E M E N T S ADMINISTRATIVE CODE DATA CO N S T R U C T I O N D O C U M E N T S VICINITY MAPCONSTRUCTION TYPE: III-B, FULLY-SPRINKLERED OCCUPANCY: R-2 APPLICABLE CODES:2012 INTERNATIONAL CODES International Building Code International Residential Code International Fire Code International Plumbing Code International Mechanical Code International Fuel Gas Code International Energy Conservation Code International Performance Code for Building and Facilities 2011 National Electrical CodeADDRESS:384 GORE CREEK DRIVE, VAIL, CO 81657 PARCEL NUMBERS: 2101-082-3800-3,4,8 TOWN OF VAIL REFERENCE:DRB130098SheetNumberSheet NameCONSTRUCTIONDOCUMENTS A0.01COVER & PROJECT INFO06 MAY 3013 S1.01STRUCTURAL PLANS AND DETAILS06 MAY 3013 A1.01EXTERIOR DEMOLITION PLANS06 MAY 3013 A1.02UNIT 3 INTERIOR DEMOLITION06 MAY 3013 A2.01UNIT 3 FLOOR PLAN06 MAY 3013 A2.02UNIT 8 PLANS / ELEVATIONS06 MAY 3013 PROJECT # 1252, 1301, 1319 UNITS 3,4, & 8 IMPROVEMENTSCONTACTSARCHITECT: BILL PIERCE970.476.6342 / bill@vailarchitects.com STRUCTURAL ENGINEER:TIM BOYLE970.476.2170 / boyleeng@qwestoffice.net DR A W I N G C O N V E N T I O N S SI T E C O V E R A G E * U n i t 3 & 4 i s n o t i n c l u d e d i n r e v i s i o n s u b m i t t a l . By Da v i d Rh o a d e s at 1: 2 3 pm , Ma y 22 , 20 1 3 B1 3 - 0 1 8 1 Ap p r o v e d b y t h e De s i g n R e v i e w B o a r d By Wa r r e n Ca m p b e l l at 8: 5 3 am , Ju n 06 , 20 1 3 RE F . REF. RE F . RE F . EXISTING DECK EX I S T I N G DE C K EX I S T I N G U N I T 4 EXISTING UNIT 3 8'-11 1/2"18'-9 1/2"6'-5 1/4"3'-11 1/4"1'-2 1/2" 4' - 8 " 4' - 8 " 4'-8" RE M O V E E X I S T I N G WI N D O W S A N D E X T E N T O F CM U R E Q U I R E D F O R N E W WI N D O W S . 12'-4 1/2" RE M O V E E X I S T I N G WI N D O W S A N D W E S T WA L L T O A C C O M O D A T E NE W W O R K . C O O R D I N A T E WI T H S T R U C T U R A L A N D PR O V I D E S H O R I N G A S RE Q U I R E D . FIELD VERIFY 15'-3" REMOVE EXISTING BAY WINDOW STRUCTURE IN ITS ENTIRETY. SEE NEW PLANS AND STRUCTURAL FOR FINAL CONFIGURATION.REMOVE EXISTING WINDOWS/DOOS AND EXTENT OF STRUCTURE REQUIRED FOR NEW WINDOWS AND DOORS.COORD WITH STRUCTURAL. FIELD VERIFY 15'-2 1/2" 12'-10 1/2" UN I T 8 C R DE C K UN I T 8 C 3'-0" op e n s t a i r t o l o f t RE M O V E E X I S T I N G W I N D O W S AN D E X T E N T O F C M U RE Q U I R E D F O R N E W WI N D O W S 4'-8 1/2" TH I S R E V I S E D OP E N I N G T O A L I G N WI T H R E V I S E D OP E N I N G B E L O W 4' - 8 " RE M O V E E X I S T I N G W I N O D W S AN D P O R T I O N O F W A L L T O AC C O M O D A T E N E W W O R K . CO O R D I N A T E W I T H ST R U C T U R A L A N D P R O V I D E SH O R I N G A S R E Q U I R E D . ISSUE RECORD 1650 Fallridge Road, Suite C-1 Vail, CO 81657 f.(970) 476-4901 p.(970)476-6342COMMON AREA IMPROVEMENTS 384 GORE CREEK DRIVE VAI, CO A1.01EXTERIORDEMOLITIONPLANSVILLA VALHALLA - VAIL Project #121006 MAY 3013 CD'S 1 / 4 " = 1 ' - 0 " 1 UN I T 3 - E X T E R I O R D E M O L I T I O N P L A N 1 / 4 " = 1 ' - 0 " 2 UN I T 8 - E X T E R I O R D E M O L I T I O N P L A N PROJECT # 1252, 1301, 1319 UNITS 3,4, & 8 IMPROVEMENTS Approved by the Design Review Board By Warren Campbell at 8:54 am, Jun 06, 2013 DN DN DN UP REF. D D GFI GFI GF I R GFIGFI GFIGFIGFI GFIGFI TD U3 1 8 EXTERIOR DECK. FINISH LEVEL MODIFIED TO 1'-0"BELOW CURRENT ELEVATION U3 0 1 JR S U I T E U3 1 7 BE D R O O M 2 U3 2 0 MA S T E R S U I T E U3 1 1 CL O S E T U3 1 4 M. B A T H U3 1 2 TO I L E T U3 1 3 BATH U303 BEDROOM 1 U304 W/ D U3 1 0 10'-10 1/4" 3 1 / 2 " 2' - 1 " 3' - 5 3 / 4 " 3 1 / 2 " 5' - 1 1 1 / 4 " CL O S E T U3 1 6 CLOS U305 32 " X 7 2 " JE T T E D T U B 48 " X 7 2 " ST E A M SH O W E R 9'-9 3/4"3'-4 3/4" F.V. 6'-4 3/4" 3'-2" U3 0 2 10'-4 1/4" FP CO A T S U3 0 2 LIVING U307KITCHENU306 DI N I N G U3 0 8 EN T R Y U3 0 1 HA L L U3 1 5 BA T H U3 1 8 RE L O C A T E D UN I T E N T R Y . CO N T I N U E LO B B Y A R E A FL O O R I N G U P TO N E W TH R E S H O L D ELEVATOR 4' - 1 0 1 / 4 " 5 1 / 2 " 5'-1"3 1/2"2'-2" 4' - 1 0 1 / 4 " 3 1/2"2'-2"NEW CONCRETE PAD FOR AIR CONDITIONER CONDENSER UNITS ST E P S DO W N ST E P S DO W N CL O S E T U3 2 1 U3 1 9 SHRUB PLANT SCREEN EX I S T I N G EX T E R I O R D E C K TO R E M A I N 6' - 0 1 / 2 " 3 1 / 2 " 4' - 7 1 / 4 " 2' - 7 1 / 4 " 3'-4" U3 1 6 BA T H U3 1 9 U3 2 1 U3 1 1 U304U303AU305U303B U3 1 3 U3 1 2 U3 1 0 U3 1 4 U3 1 7 U3 2 0 U3 2 E 3C 3D 10'-2" 3 1/2" 1'-11 1/2" 3 1/2" 3'-9 3/4" 5 1/2" 2'-8" 3 1/2" 4'-0 3/4" 4'-6" 7' - 2 1 / 4 " 5'-1" 6' - 2 1 / 2 " 3'-6 1/2"2'-5 1/4"3 1/2"4'-7" 1'-6 1/4" (FIN.) 8'-2"2'-9"2'-3 3/4" 5 6 6 3' - 6 1 / 2 " 19'-7" 6'-11 1/4" U322 2'-8" E E E 3C 3A 3B 3AU31E3G3G3G3G 2'-2" 8' - 5 1 / 4 " 3F3F E6 E6 E6 2'-1" 2'-8" 6'-8" CLR 2'-6" NEW STUD WALLS EXISTING WALLSWALL LEGEND NEW CONCRETENEW CMU WALLS TY P E 5 TY P E 6 GY P S U M P L A S T E R S K I M C O A T W I T H T E X T U R E 7/ 8 " S T U C C O S Y S T E M ( E X I S T I N G ) 8" C O N C R E T E M A S O N R Y U N I T S ( E X I S T I N G ) 1 L A Y E R 5 / 8 " T Y P E " X " G Y P S U M W A L L B O A R D ( E X I S T I N G ) 1 H O U R R A T E D UL D E S I G N : U 9 0 5 1 L A Y E R 5 / 8 " T Y P E " X " G Y P S U M W A L L B O A R D 2X 6 W O O D S T U D S A T 1 6 " O N C E N T E R W I T H B A T T I N S U L A T I O N 1 L A Y E R 5 / 8 " T Y P E " X " G Y P S U M W A L L B O A R D 1 H O U R R A T E D IB C T A B L E 7 2 1 . 1 ( 2 ) : A S S E M B L Y 1 5 - 1 . 1 3 TY P E E 3 WO O D S I D I N G BU I L D I N G W R A P / W E A T H E R B A R R I E R 2 L A Y E R S 5 / 8 " T Y P E " X " G Y P S U M W A L L B O A R D 5- 1 / 2 " M E T A L S T U D S @ 1 6 " O . C . W I T H R - 2 1 B A T T I N S U L A T I O N 2 L A Y E R S 5 / 8 " T Y P E " X " G Y P S U M W A L L B O A R D 2 H O U R R A T E D UL D E S I G N : U 4 2 3 EX T E R I O R IN T E R I O R TY P E E 6 RE S I D E N T I A L U N I T CI R C U L A T I O N / L O B B Y ST U C C O S Y S T E M BU I L D I N G W R A P / W E A T H E R B A R R I E R 2 L A Y E R S 5 / 8 " T Y P E " X " G Y P S U M W A L L B O A R D 5- 1 / 2 " M E T A L S T U D S @ 1 6 " O . C . W I T H R - 2 1 B A T T I N S U L A T I O N 2 L A Y E R S 5 / 8 " T Y P E " X " G Y P S U M W A L L B O A R D 2 H O U R R A T E D UL D E S I G N : U 4 2 3 EX T E R I O R IN T E R I O R ISSUE RECORD 1650 Fallridge Road, Suite C-1 Vail, CO 81657 f.(970) 476-4901 p.(970)476-6342COMMON AREA IMPROVEMENTS 384 GORE CREEK DRIVE VAI, CO A2.01UNIT 3 FLOOR PLANVILLA VALHALLA - VAIL Project #121006 MAY 3013 CD'S 1 / 4 " = 1 ' - 0 " 1 UN I T 3 R E V I S E D P L A N Un i t s 3 , 4 , & 8 W i n d o w S c h e d u l e Ty p e M a r k O p e r a t i o n C o u n t SI Z E Si l l H e i g h t He a d He i g h t Ma t e r i a l F i n i s h C o m m e n t s Wi d t h H e i g h t 3A C A S E M E N T 2 1 ' - 1 0 " 5 ' - 8 " 2 ' - 8 " 8 ' - 4 " A L U M C L A D W O O D D K BRONZE ANODIZEDHEAD HEIGHT ABOVE LOWERED FLOOR (12") 3B F I X E D 1 3 ' - 6 " 5 ' - 8 " 2 ' - 8 " 8 ' - 4 " A L U M C L A D W O O D D K BRONZE ANODIZEDHEAD HEIGHT ABOVE LOWERED FLOOR (12") 3C S L I D E R 2 4 ' - 6 " 4 ' - 4 " 3 ' - 0 " 7 ' - 4" A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D 3D S L I D E R 1 4 ' - 6 " 5 ' - 8 " 1 ' - 8 " 7 ' - 4" A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D 3F S L I D E R 2 4 ' - 6 " 3 ' - 1 0 " 3 ' - 0 " 6 ' - 10 " A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D 3G F I X E D 4 3 ' - 0 " 7 ' - 4 " 1 ' - 0 " 8 ' - 4 " A L U M C L A D W O O D D K BRONZE ANODIZEDHEAD HEIGHT ABOVE LOWERED FLOOR (12") 8A S L I D E R 1 4 ' - 6 " 4 ' - 2 " 3 ' - 0 " 7 ' - 2 " A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D 8B S L I D E R 1 4 ' - 6 " 5 ' - 2 " 1 ' - 8 " 6 ' - 1 0 " A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D 8C S L I D E R 1 4 ' - 6 " 4 ' - 1 0 " 2 ' - 0 " 6 ' - 1 0 " A L U M C L A D W O O D D K BRONZE ANODIZEDFIELD VERIFY / MATCH EXISTING / MAX OPENING 8D F I X E D T R A P E Z O I D 1 4 ' - 6 " 6 ' - 5 " 6 ' - 1 1 " 1 3 ' - 4 " A L U M C L A D W O ODDK BRONZE ANODIZEDFIELD VERIFY / MATCH EXISTING / MAX OPENING 8E F I X E D T R A P E Z O I D 1 3 ' - 4 " 1 ' - 1 1 " 7 ' - 1 0 " 9 ' - 9 " A L U M C L A D W O O D DK BRONZE ANODIZEDFIELD VERIFY / HEAD TO MATCH ROOF SLOPE 8F F I X E D T R A P E Z O I D 1 3 ' - 4 " 3 ' - 4 " 7 ' - 1 0 " 1 1' - 2 " A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D FIELD VERIFY / HEAD TO MATCH ROOF SLOPE 8G F I X E D T R A P E Z O I D 1 3 ' - 4 " 4 ' - 8 1 / 2 " 7 ' - 1 0 " 1 2 ' - 6 1 / 2 " A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D F I E L D V E R I FY / HEAD TO MATCH ROOF SLOPE 8H C A S E M E N T 1 1 ' - 8 " 3 ' - 2 " 3 ' - 0 " 6 ' - 2" A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D E F I X E D 6 3 ' - 4 " 6 ' - 4 " 1 ' - 0 " 7 ' - 4 " AL U M C L A D W O O D D K B R O N Z E A N O D I Z E D Un i t s 3 & 8 D o o r S c h e d u l e Do o r Nu m b e r Do o r S i z e O p e r a t i o n R a t i n g F r a m e T y p e Fi n i s h Do o r F r a m e C o m m e n t s U3 1 E 3 2 " x 1 0 0 " A L U M I N U M A N O D I Z E D P R E - F I N I S H E D U3 2 E 5 4 " x 8 8 " P A T I O S L I D I N G A L U M I N U M A N O D I Z E D P R E - F I N I S H E D U8 1 E 5 4 " x 8 8 " P A T I O S L I D I N G A L U M I N U M A N O D I Z E D P R E - F I N I S H E D U3 0 1 3 6 " x 8 4 " 6 0 M I N W O O D U3 0 2 4 8 " x 8 4 " W O O D U3 0 3 A 2 4 " x 8 4 " W O O D U3 0 3 B 2 4 " x 8 4 " W O O D U3 0 4 3 0 " x 8 4 " W O O D U3 0 5 4 8 " x 8 4 " W O O D U3 1 0 3 0 " X 8 4 " W O O D U3 1 1 3 4 " x 8 4 " W O O D U3 1 2 3 0 " x 8 4 " W O O D U3 1 3 2 4 " x 8 4 " W O O D U3 1 4 3 6 " x 8 4 " W O O D U3 1 6 2 4 " x 8 4 " W O O D U3 1 7 3 2 " x 8 4 " W O O D U3 1 8 2 4 " x 8 4 " W O O D U3 1 9 2 4 " x 8 4 " W O O D U3 2 0 3 2 " x 8 4 " W O O D U3 2 1 2 4 " x 8 4 " W O O D U3 2 2 2 0 " x 8 4 " W O O D PROJECT # 1252, 1301, 1319 UNITS 3,4, & 8 IMPROVEMENTS WA L L T Y P E S Ap p r o v e d b y t h e De s i g n R e v i e w B o a r d By Wa r r e n Ca m p b e l l at 8: 5 5 am , Ju n 06 , 20 1 3 REF.REF.UNIT 8CR EX I S T I N G O U T D O O R DE C K A R E A T O R E M A I N . SL O P E T O P P I N G S L A B AW A Y F R O M D O O R TH R E S H O L D UNIT 8CU81E 8A8B 8D E E E 8C 8E 8F 8G 11'-6" E3 E3 E3 OP E N T O SE C O N D LE V E L B E L O W 8H FIRST LEVEL 0"SECOND LEVEL 9' - 0"THIRD LEVEL 18' - 0" 8B 3D 3C8A 3B3A3A3G3G3G3G FI R S T L E V E L 0" SE C O N D L E V E L 9' - 0 " TH I R D L E V E L L O F T 26 ' - 8 1 / 2 " TH I R D L E V E L 18 ' - 0 " 8F 8G 8E E E E E E E 3C8C 8D 5 " / 1 2 " ( V E R I F Y ) 5" / 12" (VERIFY) LI V I N G -1 ' - 0 " 8H ISSUE RECORD 1650 Fallridge Road, Suite C-1 Vail, CO 81657 f.(970) 476-4901 p.(970)476-6342COMMON AREA IMPROVEMENTS 384 GORE CREEK DRIVE VAI, CO A2.02UNIT 8 PLANS /ELEVATIONSVILLA VALHALLA - VAIL Project #121006 MAY 3013 CD'S 1 / 4 " = 1 ' - 0 " 1 UN I T 8 R E V I S E D P L A N Un i t s 3 , 4 , & 8 W i n d o w S c h e d u l e Ty p e M a r k O p e r a t i o n C o u n t SI Z E Si l l H e i g h t He a d He i g h t Ma t e r i a l F i n i s h C o m m e n t s Wi d t h H e i g h t 3A C A S E M E N T 2 1 ' - 1 0 " 5 ' - 8 " 2 ' - 8 " 8 ' - 4 " A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D H E A D H E I G H T A B O V E L O W E R E D F L O O R ( 1 2 " ) 3B F I X E D 1 3 ' - 6 " 5 ' - 8 " 2 ' - 8 " 8 ' - 4 " A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D H E A D H E I G H T A B O V E L O W E R E D F L O O R ( 1 2 " ) 3C S L I D E R 2 4 ' - 6 " 4 ' - 4 " 3 ' - 0 " 7 ' - 4" A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D 3D S L I D E R 1 4 ' - 6 " 5 ' - 8 " 1 ' - 8 " 7 ' - 4" A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D 3F S L I D E R 2 4 ' - 6 " 3 ' - 1 0 " 3 ' - 0 " 6 ' - 10 " A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D 3G F I X E D 4 3 ' - 0 " 7 ' - 4 " 1 ' - 0 " 8 ' - 4 " A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D H E A D H E I G H T A B O V E L O W E R E D F L O O R ( 1 2 " ) 8A S L I D E R 1 4 ' - 6 " 4 ' - 2 " 3 ' - 0 " 7 ' - 2 " A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D 8B S L I D E R 1 4 ' - 6 " 5 ' - 2 " 1 ' - 8 " 6 ' - 1 0 " A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D 8C S L I D E R 1 4 ' - 6 " 4 ' - 1 0 " 2 ' - 0 " 6 ' - 1 0 " A L U M C L A D W O O D D K BR O N Z E A N O D I Z E D F I E L D V E R I F Y / M A T C H E X I S T I N G / M A X O P E N I N G 8D F I X E D T R A P E Z O I D 1 4 ' - 6 " 6 ' - 5 " 6 ' - 1 1 " 1 3 ' - 4 " A L U M C L A D W OO D D K B R O N Z E A N O D I Z E D F I E L D V E R I F Y / M A T C H E X I S T I N G / M A X O P E N I N G 8E F I X E D T R A P E Z O I D 1 3 ' - 4 " 1 ' - 1 1 " 7 ' - 1 0 " 9 ' - 9 " A L U M C L A D W O O D DK B R O N Z E A N O D I Z E D F I E L D V E R I F Y / H E A D T O M A T C H R O O F S L O P E 8F F I X E D T R A P E Z O I D 1 3 ' - 4 " 3 ' - 4 " 7 ' - 1 0 " 1 1' - 2 " A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D FI E L D V E R I F Y / H E A D TO M A T C H R O O F S L O P E 8G F I X E D T R A P E Z O I D 1 3 ' - 4 " 4 ' - 8 1 / 2 " 7 ' - 1 0 " 1 2 ' - 6 1 / 2 " A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D F I E L D V E R I FY / H E A D T O M A T C H R O O F S L O P E 8H C A S E M E N T 1 1 ' - 8 " 3 ' - 2 " 3 ' - 0 " 6 ' - 2" A L U M C L A D W O O D D K B R O N Z E A N O D I Z E D E F I X E D 6 3 ' - 4 " 6 ' - 4 " 1 ' - 0 " 7 ' - 4 " AL U M C L A D W O O D D K B R O N Z E A N O D I Z E D PROJECT # 1252, 1301, 1319 UNITS 3,4, & 8 IMPROVEMENTS 3 / 1 6 " = 1 ' - 0 " 2 UN I T 8 - L O F T L E V E L 3 / 1 6 " = 1 ' - 0 " 3 So u t h E l e v a t i o n - R EV I S E D U n i t s 4 & 8 3 / 1 6 " = 1 ' - 0 " 4 We s t E l e v a t i o n - R E V I S E D U n i t s 4 & 8 De s i g n R e v i e w St a f f A p p r o v a l By Wa r r e n Ca m p b e l l at 8: 5 5 am , Ju n 06 , 20 1 3