Loading...
HomeMy WebLinkAboutP05-0103 TOWN OF VAIL �EPA�tTMENT OF COMMUNI�Y DEVELOPIwIENT 75 S. FRONTAGE ROAD VAIL, CO 81b57 97U-479-2138 P�OTE: THIS PERMIT 1wIUST BE PQSTED �N J�BSITE AT ALL TIMES I'LUMBING PERMI'�' Permit #: POS-0103 .�ab Address: Status . . . : ISSUEU Locativn.....: 825 'W. FOREST RD Applied . . : Q8f02/2005 Pazcel No...: 210107207402 Issued . . . 08/18/20(}S Project No : � � �G��—c��� � Expires . .: 02/14/20(l6 aWNER VA�L CORP 08/02/2005 FO BOX 7 VAIL, CO 81658 APPLICANT MID COiTNTY PLUMBING & HF,P.TIN08/02/2005 Phone: 970-468-492g P. O. BOX 23186 S ILVERTHOR1tiTE �O 80498 License: 269-P CONTRACTOR MID COUNTY PLUMBING & HF,ATIN08/02/2005 Phone: 97�°468-4924 P. O. BUX 23186 SILVERTHORNE CO 80498 License: 269-P Desciption: INSTALL ALL PLUMBING POR N:EW CONSTRUCTION OF BUILDING#1, UNITS 15 & 16 Valuation: $57,753.00 Fireplace Inforsnation: Restricted: ?? N of Gas Appliances: ?? #of Gas T.ogs: ?? il of Woad Paller. ?? :s�*s*srr**r**,w******��**r***********s*****:**s*��*��s*s:a�ss***s«s:* FEE SUMMARY #####ii#####►####*#t##*###4#�►#�k#####################t##i�i#:k�# Plumbing---> $870.00 Restuarant Plan Review--> $o.oo Total Cafculated Fees—> S1,090.50 PEa►�Check---> $217.5o DRB Fee--------------------> $U.oo Addiuonal Fees----------> So.oD Investigation-> $0.00 TOTAL FEES-------------> $1,0 90.5 U Total Permit Fee----------> $i,0 9 0.5 d Will Call-----> $3.00 Payments-------- -> S�,094.50 BA,LANCE DUE---------� $0.00 �#t#�###*�k####**############lFik#�#####�k###ok�k#*#�:S###*kel:##�k:k4�kekt###�k#.###�Is�k#*�k�k�k*#####*##*#*�t*�kek*N okeC47�#8#�*#%s#&�##�##A�**#*#########*#######�k#��k#*�* Item: 05100 BUILDING D$PARTMENT 08/02/2005 JS Action: AP Item: 05600 FIRE DEPARTMEN]T CC►NDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQ�:JIRED TO CHECK F�R CODE COMPLIANCE. *x�.*.��**.,:*�**:«:�«::.::«::..:*.**�**«�:*.���.�.*.:.*:�***.*#***:*****.**��:*.::��***�*�***��*..:*��*��**��*�.:�«*:*�*�**:�.***����*.�*�*�*�*::. DECLARAT`IONS I hereby acknowledge that I have read this a�plication, filled out in full the information required, completed an accurate plot plan, and state that all the info�mati4n as required is correct. I agree to comply with�he information and plot plan, ta comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Bui�ding and Resid�ntial Codes and other ordinances of the Town applicable �t�ereto. REQUESTS FOR INSPECTI�N SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHQNE AT 479-2149 OR AT�UR OFFICE FROM 8:00 AM-4 PM. .��� - � � �*�*+�*�:�:�***��**�*******�*�*�*��**�>k*****************��#�**�x��+�+*�+�******************�*�* TOW�T OF VAIL, COLORI�DO Statement �*****�*�:****�:��*+�:*�****��*���x���*************a*******��#***************�************�***** Statement Number: R050001325 Amount: $1,090.50 OS/18/200502:57 PM Payment Method: Check Init: LT Notation: Mid-County Plumbing / ck3135 Permit No: P05-�1.03 Type: FLUMSING P�RMIT Parcel No: 2101-072-Ci700-2 Site Address: Location: 825 W. FOkEST RD Total F'ees: $1, 090.5o This Payment: $1,090.50 Total ALL Pmts: $1,090.5o Balance: $0.00 ##****#*###*#***#####*###*##*##**i**=k***+k�k#*#*�k#+I�t*##*###*f**�k**#**####*#**##******#**#�k###�k ACCOUNT ITEM L�ST: Account Code Description Current Pmts -------------------- ------------------------------ ------------- PF OO100Q03112300 PI�AN CHECK FEES 217.50 PP OOlOfl0031111Qq PI�CIMBING P�RNIIT k'EES 874.00 WC OOlOflOQ3112800 WILL CAI,L INSPECTIQIV FEE 3 ,00 �.��'� i �f- �c APPLICATION�LL NO'�BE QCCEPTED IF INCaMPLE�R UNSIGNE � �] l.�!�j� f Proje�t #. �`�'! Bvilding Rermit #: o ��Z3J Plumbing Permit #: / nS�n�, ,� 970-479-2149 (Inspection�- ����' �� F PL APPLICATION 75 S. Frontage Rd. � Vail, Colorado 81657 �� CON�RACTOR INFORMATI4N Plumbing Contractor: Tawn of Va91 Reg. No.: Contact and Phone #'s: l''J/ �/'✓ -s r� r �'�O / ��� /L,//t� L`—�t,� ./'/��j �f.� �L5 � E-Mai� Address: � d: � Cantractor Signature• � � � :��, COMPLETE VALUATIQN FOR PLUMBING PERMIT (Labor& Materials) PLUMBING: $ t—� � Contact Ea le Coun Assessors O�ce at 9T0-328-8644 or visit www,ea /e-cvun .com for Parce/# Parcel # �/� �� -;1� 7�� C Job Name: G�^��' ���.`�/� �'�5 r�.�.-�S Job Addr�ss: a��`c��B�'`n�t�,.�-d��� � Legal Descriptio� Lot: Blnck: � Filing: � Subdivisian: Owners Name:���r.� �r Addr��;�,K „� ,,� Phone: �, Engineer: Addres:a: Phone: Detailed description of work: �,/�/ / /�� ��I/P �li� / /'k'� �� . Work Class: Nevy�cj Addition O Alteration ( } Repair O Other O Type of Bidg.: Single-family O DupleX� Multi-family{ ) Commercial O Restaurant O Other O No. of Existing Dwelling Units in this b�tilding: � No. of Accornmodation 1Jnits in this b�iiding: �_ Is this a conversion from a woad burning firepla�e to an EPA Phase II dev�ce? Yes O No S ) :��*��**,��*,�**,�*,��:*��****��t*�:�**,�,��,��;.�,�1=i0R OF�ICE USE ONLY�,�*,�*x**,��**��*�*,�**�*��*�*,��,r�:*+**�* Other Fees: Date Received: DRB Fees: Acce ted B : Planner Si n-off: � � � � � � � ��� �-� �y •� �` 11Vai11datalcdevlFORM5IPERM��'S\Pd.MBPERM.DOC � 07f2,6ROq2 s • � � 06-2�-2006 Insp�ection Request Re porting Page 29 4:36 prrz Va�lt O i v Of Requested Inspect Date: Friday,June 30,20p6 Inspection Area: CG 5ite Address: 825 FfJR�ST RD VAIL 825 4N. FOREST RD AlP1D Information Activity: M05-0214 Type: &MECH Sub Type: NDUP Status: ISSUED Const Type: Occupancy: Use: lnsp Area: CG Owner: VAIL CORP Applieant: h�ID COUNTY PLUMBING& HE:ATING Phone: 97Q-468-4924 Contractor: MID GOUNTY PLUMBING&HE_ATYNG Phone: 970-468-4924 Description; INSTALL ALL HEAT WITH POSS16l�E AlC ADDITION FOR NEW CONS7RUCTION OF BUILDING#1, UNITS 15� 16 Reauested Inst�ection(s) /� Item: 390 MECH-Final �'C� Requested Time: 02:00 PM Requestor: RA Ne4son Mi4�e Phane: 471-0071 Camments: Bldg 1, 471-0071 Assigned�`o: GDENCKLA ��C��� �ntered By: DGQLDEN K Action: Time Exp: � Comrnent: NS APPL`r'TO BO�NO. 1.PIPE CQNDENSATE TO FLOQR DRAIN: 2.COIVDENSATE REQS NEUTR,ALIZATION PER IPC SEC 803.2.°� 3.SUPPOI�T ALL PiPING PE:R CO�E I�J MECH ROOM. v�.� r� 4.PIPE I-6UMIDIFiER TO DR,AIfV. / 5.RECEIVED VENTING CO�JFIGUR�ATI01� 1N FiLED.'� �' &.T&P VALV �� PERATLY. 'C���J� � ��,(r.I�� IN SN0INMEL UNiT 15.�/"`���p Q�^���� �IMl7`� OOD REQD 30"'MkN UN:T 15. O.CHECK ALL EXHAUST FANS F PERATII�N. ���� ,�µ�"�"' �` �� Ins ction Histo ftem: 200 MECH- ough "A���proved*' 12/23/05 Inspector: MRQY!-R A�ction: PA PARTIAL APPROVAL Comment: Unit 16-Parkial ventiEation inspection did not include any ducting in crawl spaee. Supply and retum ducting, boiler direct vents, kitchen exha�st, exhaust fans and dryer vents-ok Unit 15-Not ready for inspection. Sea!ducts, support ducts and complete ducting. 01l11106 Inspector: GCD Actio�: CR CORRECTION REDUIRED Camment: UMT 15 1.PROVIDE BDD AT TERMI�JAT�ON OF DRYERS INLINE CIAMPERS N�T APPROVED. 2.SECONDARY LIPJT TRAP MAY BE REQUIRED�OR DRYER BOOSTER FAN 3.FLEXABL.E RETURN IS CRUSHED. 4.FiAVE ENG REVIEW �WELLING �OR GARAGE EXHAUST SEPERATION 5.THERE IS NO RE:TURN FOR THE UPPER LEVEL HAVE ENG REVIEW. THE DUCT WORK FUO UNlT 15 IS APPROVED i�J CRAWLSPACE, LOWER MAIN AND UPPE�R LEVELS.THIS INCLUDES SUPPLY RETURN, KITCHEN,BATH AND�FZYER EXHAUST DUCTS. 01/17/06 Inspector: GCD Action: AP APPROVE� Gomment: CRAWLSPACE DLCT WORK APPf�OV�D UNITS 15,16 Item: 310 MECH-�lea#in9 10l31l05 fnspector: SHAH�d Actian: P{ PARTfAL 114SPECTION Comment: INSPECTED WIZBRO IN UNIT 16 ONLY FOR 100PS1. 11lD1/05 Inspector: GCD Actian: PI PARTNAL II�S�ECTION Comment: L1N1T 15 IN FLOOR HYDRONICS 100psi TEST 12l08l05 Inspector: GCD Action: PI PARTIAL INSPECTIQN Cornment: HYDRONIC SUPPLY ANQ RETURIV MAINS 12/23/05 Inspector: MROYER Ackion: PI PARTIAL INSP�CT90N Comment: Unit 16-Heat mains ok- 100 psi. Item: 315 PLMB-Gas Piping *"Approved"' 12123I05 Inspector. MROYER Action: CR CORRECTION REQUiRED Comment: Gas piping unit 15-Not hol�ing pr�ssure. No inspection performed. 01/05/06 Inspector: GCD Action: AP APPROVEQ Comment: UN1TS 15 AND 16 30psi TEST. XGEL METER RELEASE REPT131 Run Id: 5452 � � JUH-29-06 il:i9A�d FR0�1-SU8 2ER0 SER�iCE + T-993 P.0210Z �-568 � � ��� Ta: cre���i�,v��ca���a�n$���������to; �'R4Nf: Coleman�e#zlaff.Teciv�ic�l Advisc�r, WolfAppIiance Ca, Inc. StTBJLCT: Distance required frc�m haod to countertop. DATE: June 29,2446 To �'�iorn Tt May Canceran: Ques�ion has arisen in reaards to Wolf's specificatadn o£3Q"betwe�n the bastom of ve�tilatinn hood ancf ct�unt�.r tQp:surface. Th�installatian in questian}�.as placed the haad a �s"lawer ta 29 '/z°°from the coc.nter tag surfacc. This q�estion has been g�nse,ci tc�rim Pglkey, Certif�c�tion En�in�er_ �[is raspanse was th�t this installation daes not create a safcty vr�erformsnce cor�cern. .. Th�3CS"specific�idn i�r�oc giwer�as a heat toleran�e�'Qr saf�ty. The 30"spea;ficat��n is a basic recamm.enciation f�r id�al perfos�nce and dra.ftin�c�f air be�ween bottam af hc�od,rangc,and cou�ter uy�/ca�sinetry. Tect�ical�y�sgeaki.ng,'I�olf rar�ges�re CSA tes��d and�ppmv�l without ve�tiladon as lo���r distance to cc�mbusribl�surfaces are [z�.et. It is our apinion that the range and hood u�sta�lation at Gare Creek Place,U:r�it #1 S, Avan, Co. doe�nat present any s>�fery or perforra�nce tonccros. Sincer�ty, � �Cr�lem�n�2.etz�a:ff /'�����'''" TEChnic3l Rt��vis+�r Wolf Appliance Coznpany, ,Inc. , �'otema�.r�tzisff�wol.C�p�r,��'az�ce.com � � � � � � � � # _ - . . . . .. . .� e ; s s � � � a6-29-2006 Inspection Request Reporting Page 17 4:36 pm g.__. ..-__-- Vail, ,�O_-Ci_#v Of _ Requested Inspect Dafe: Friday,June 30, 20�6 Inspection Area: CD 5ite Address: <wane Listed> 825 W. FOREST RQ AlPlD Information Activity: '�05-0103 Type: E3-PLMB Sub Type: ADUP Status: ISSUED Const Type: Occupancy: Use: lnsp Area: CD ��nrner; VAIL CORP Applicant: MfE]COUNTY PLUMBING 8� HFATiNG Phone: 970-468-4924 Gantractor: MI�COUNTY P�UM8ING& Hf=ATING Phane: 97�-468-4924 Description: INSTALL ALL PLUMBING FOR NEW CO�ISTRUCTION �F BUILDING#1, UNITS 15& 16 Natice: CON7RACTORS LlCENSE IS I_XPIRED-JSUTHER Requested Ins�ection(s1 Item: 290 PLMB-Final Requested Time: 02:30 PM Requestor. MID COUNTY PLUM ING 8 HEAT��} Phane: 97D-468-4924 Cornments: Bldg 1, 471-0071 �n`���`r/ YY "r' Assigned To: GDENCKLA Entered By: DGOLDEN K Action: Tine Exp� Comment: R DI3HWASHER'1P�3EC 802.1.6 �i' �, �� � Inspectian History Item: 210 PLMB-Underg round It�m: 220 PLMB-Rou9 h7D.W.V. '"Approved" 12/08/05 Inspector: GCD Action: AP APPROVED Gommen#: UMT 15 5psi TEST STUDOR VENT LOWER L�V�L LAV. �D1105106 Inspector: GCD Action: APCR APPROVED/CORRECTION REQD Comment: ADD VENT F�OR WASHER AND FLOOR DRAIN. UNIT 16 2 GAGES 5psi TEST. Iterr�: 230 RLMB-RoughlNlater **Approved** 12/08l05 Irtspector: GCD Action: AP APPROVED Comment: UN1TS 15 100_psi TE=ST OU05l06 Inspector: GCD Action: AP APPROVED Comrvienk: UNI�' 16 1a0psi TEST Item: 240 PLMB-Gas Pipinq Item: 250 PLMB-Pool/Hot Tub Item� 260 PLMB-Misc.. Item: 290 PLMB-Final 06128(06 Inspector: GCD Act�on: CR CORRECTION REQUIRED Comment: PRDVIDE AIR GAP FOR DiS�WASHER IPC SEC 802.1.6 ������� � REPT131 Run Id: 5452 , �