Loading...
HomeMy WebLinkAboutF13-0023 Data and Calcs.pdf r 10864 WEST COCO PLACE RFS LTTTLETON,CO 80127 Tel: (303) 798-4448 Assurance Fire Systems Fax: (720) 922-7698 Chris @AssuranceFireSystems.com FIRE SPRINKLER PRODUCT SUMITTALS FOR Marshall Remodel 193 Beaver Dam Road Vail, CO ■ Hydraulic Overview Job Number: 1 Report Description: Residential Job Job Number Design Engineer 1 AL RUCH Job Name: Phone FAX MARSHALLL RESIDENCE 720-227-3331 Address 1 State Certification/License Number 193 BEAVER DAM ROAD Address 2 AHJ VAIL,CO Address 3 Job Site/Building System Density Area of Application 0.100gpm/ft2 900.00ft2(Actual 143.61ft2) Most Demanding Sprinkler Data Hose Streams 4.9 K-Factor 13.00 at 7.039 0.00 Coverage Per Sprinkler Number Of Sprinklers Calculated 256.00ft2 3 System Pressure Demand System Flow Demand 106.902 39.57 Total Demand Pressure Result 39.57 @ 106.902 +17.869(14.3%) Supplies Check Point Gauges Node Flow m Hose Flow(,apm) Static si Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(gpm) 4 500.00 125.000 100.000 MARSHALL REMODEL Supply at Node 4(500.00,0.00, 125.000, 100.000) 150 T!H' 6, 77- ErF m�� r ml 135 Static Pressure 125.000 120 9.57'@ 106.902 vy 105 90 =. Q 3 75 to a 60 System demand curve 45 30 15 0 Q9 5000150 200 250 300 350 400 450 500 Water flow,gpm LH ©M.E.P.CAD, Inc. AutoSPRINK@ VR8 v8.1.10 06/03/2013 6:41:18PM Page 1 MINode Analysis Job Number: 1 Report Description:Residential Node Elevation Foot Fittings Pressure(psi) Dischar e m 4 29'-2 S 106.902 39.5 101 26-103/4 S r-7.390 7.390 13.3 102 26-103/4 S r-7.039 7.039 13.0 103 26-10% S r-7.310 7.310 13.2 1 22'-0'/4 T(2'-O),Tr 0'-6 9.886 2 22'-0'/4 T 2'-0 10.291 3 9'-2 EE 1'-0 75.432 M[J©M.E.P.CAD, Inc. AutoSPRINK®V R 8 v8.1.10 06/03/2013 6:41:25PM Page 2 ■ Hydraulic Analysis Job Number: 1 Report Description: Residential Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length Iff•••••Route 1 ••••• DR 1.0550 13.00 4.77 150 0.037751 15'-0 Pf 0.736 102 26'-10'/4 13.00 4.9 7.039 Sprinkler, 4'-6 Pe 2.112 1 22'-0'/4 9.886 2E(2'-0),Tr(0'-6) 19'-6 Pv BL 1.0550 26.25 9.63 150 0.138501 0'-11 Pf 0.405 1 22'-0'/4 13.25 9.886 Flow(q)from Route 2 2'-0 Pe 2 22'-0'/4 10.291 T(2'-0) 2'-11 Pv BL 1.0550 39.57 14.52 150 0.295956 125'-11'/ Pf 59.566 2 22'-0'/4 10.291 31'-6 Pe 5.574 3 9'-2 75.432 9E(2'-0),3T(2'-0),8Tr(0'-6), 157'-51/ Pv C(2'-0),CV,cplg(0'-6), BFP(-12.973),EE(1'-0) UG 0.9950 39.57 16.33 150 0.393612 101'-11'/ Pf 40.140 3 9'-2 75.432 Supply, Pe -8.671 4 29'-2 106.902 1 101'-11'/ Pv 0.00 Hose Allowance At Source 4 39.57 •••••Route 2••••• DR 1.0550 13.25 4.86 150 0.039093 7'-10'/ Pf 0.465 103 26'-10'/4 13.25 4.9 7.310 Sprinkler, 4'-0 Pe 2.112 1 22'-0'/4 9.886 E(2'-0),T(2'-0) 11'-10'/ Pv •••••Route 3••••• DR 1.0550 13.32 4.89 150 0.039492 13'-11'/ Pf 0.789 101 26'-10'/4 13.32 4.9 7.390 Sprinkler, 6'-0 Pe 2.112 2 22'-0'/4 10.291 2E(2'-0),T(2'-0) 19'-11'/ Pv Equivalent Pipe Lengths of Valves and Fittings(C=120 only) C Value Multiplier Actual Inside Diameter 4.87 Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) =Factor Multiplying Factor 0.713 1.16 1.33 1.51 M[J©M.E.P.CAD, Inc. AutoSPRINK®VR8 v8.1.10 06/03/2013 6:41:28PM Page 3 ■ Hydraulic Analysis Job Number: 1 Report Description: Residential Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BaIV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 90° FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen-Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DeIV Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe E 90°Elbow Pe Pressure due to elevation difference between indicated points UG Underground EE 45°Elbow Pv Velocity pressure at a point in a pipe Eel 11'/0°Elbow Ee2 221/2°Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap M[J©M.E.P.CAD, Inc. AutoSPRINK®VR8 v8.1.10 06/03/2013 6:41:28PM Page 4 ■ Hydraulic Graph Job Number: 1 Report Description: Residential Supply at Node 4 150 I 135 I Static Pressure 125.000 120 39.57 @ 106.902 105 90 N I Q 75 N N I a 60 System demand curve 45 30 15 0 050 100 150 200 250 300 350 400 450 500 Water flood,gpm Hydraulic Graph Supply at Node 4 Static:Pressure 125.000 Residual:Presure 100.000 s @ 500.00 Available Pressure at Time of Test 124.771 @ 39.57 System Demand 106.902 @ 39.57 System Demand(Including Hose Allowance at Source) 106.902 @ 39.57 LM,©M.E.P.CAD, Inc. AutoSPRINKO VR8 v8.1.10 06/03/2013 7:00:22PM Page 1 Page : 1 of 7 EA SENJU SPRINKLER CO.,LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8461 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type.These are decorative and fast response.The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc.,which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for the residential occupancies and it is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R;or,wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar'/2) K-factor that meets the required residential flow rates with minimal residual pressure,which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents' escape or evacuation in case of fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act(S.3874)endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No.0036785 Date : Nov/1912012 Page : 2 of 7 TECHNICAL DATA 2—Y1s"(9552mm) Markin Approvals: rUL„s Listed, NSF-61-G NPTi/ Manufacturer Sprinkler Identification Number(SIN): SS8461 Country origin UL Mark Maximum Working Pressure: 175psi (12.1bar) 3 Markin Discharge Coefficient Nominal K-Factor : Lot No. g ( ) � Year of Manufacture K=4.9 GPM/psi112(70.6 LPM/barl12) Temperature Rating r NSF Mark Temperature Rating: = 4 162T (72°C)Sprinkler with 140T (60°C)Cover Plate 5 O Body(copper Alloy) 175T (79°C)Sprinkler with 162T (72°C)Cover Plate N 2 02 Deflector(Phosphorus Bronze) 6 Os Gasket(PTFE) Color Code(Sprinkler) ®Fusible Metal(Solder) 162T (72°C): Uncolored Os Heat collector(copper) ° ©Cover Plate Assembly 175T (79C): White 2-5ja"(q5 68mm) Color Code(Cover Plate) or 3-Y4"(083mm) 140T (60 0C): No Mark or 2-%-square(068mm) 162T (72 9C): White-Color Mark Vertical Adjustment: 112 inch (12.8 mm) FIGURE 1. Model RC-RES K=4.9 Cover Plate Finishes: color Code White Painted, Ivory Painted, Nickel Plated or o o Markin Any Color(Choose a color of acceptable colors) O O Control No.:61`37 Physical Characteristics: Ref. Figure 1 RES tor y g K—factor:K4.9 SIN:SS8461 O O 0 0° COVER PLATE SPRINKLER (Top view) (Bottom view) OPERATION FIGURE 1-1. Markinq (Color Code) In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then, the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, internal components of the sprinkler to fall apart.This leads to allow the water flow to be distributed on the affected by fire area. (Ref. Figure 2) 'lk Normal Condition y Cover Plate Operation y Sprinkler Operation y Water Discharge FIGURE 2. OPERATION PROCESS (The figure is for illustrative purpose only) Document No.0036785 Date : Nov/1912012 Page : 3 of 7 DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company. Include sketches and technical details as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. The spray from the sprinkler is distributed radically outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as small as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D or 13R for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments The Model RC-RES should not be installed where they may be subjected to a corrosive environment including the following: (1) Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. (2) Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association)—Solder Joint) All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for system designed to NFPA 13D or 13R are given in Table A& Table B as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of"design sprinklers"as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers.The minimum required discharge from each of the four sprinklers is to be the greater of the followings; The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. A minimum discharge 0.1 GPM/sq.ft. [4.07(L/min)/ sq.m] over the "design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. Document No.0036785 Date : Nov/1912012 Page : 4 of 7 TABLE A. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA Temperature Rating.162T (72°C)Sprinkler with 140T (60°C)Cover Plate Maximum Coverage Minimum Flow(b) and Minimum Flow(b)and Area(a) Spacing Residual Pressure Residual Pressure m) (Between the Sprinklers) for Horizontal Ceiling for Sloped Ceiling (m x m ft.x (Max.2 inch Rise for 12 inch Run) (Max. 8 inch Rise for 12 inch Run) MAXIMUM MINIMUM FLOW PRESSURE FLOW PRESSURE 12 x 12 12 ft. 13GPM 7.Opsi 13GPM 7.Opsi (3.7 x 3.7) (3.7 m) (49.2LPM) (0.050MPa) (49.2LPM) (0.050MPa) 14 x 14 14 ft. 13GPM 7.Opsi 13GPM 7.Opsi (4.3 x 4.3) (4.3 m) (49.2LPM) (0.050MPa) (49.2LPM) (0.050MPa) 16 x 16 16 ft. 9 ft (2.7m) 13GPM 7.Opsi 13GPM 7.Opsi (4.9 x 4.9) (4.9 m) (49.2LPM) (0.050MPa) (49.2LPM) (0.050MPa) 18 x 18 18 ft. 18GPM 13.5ps1i (5.5 x 5.5) (5.5 m) (68.1 LPM) (0.093MPa) [See(c)&(d)] [See(c)&(d)] 20 x 20 20 ft. 21 GPM 18.4psi [See(c)&(d)] [See(c)&(d)] (6.1 x 6.1) (6.1 m) (79.5LPM) (0.127MPa) TABLE B. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA Temperature Rating:175T (79°C)Sprinkler with 162T (72°C)Cover Plate Maximum Coverage Areaw Spacing Minimum Flow and and Residual Pressure ft.x ft. (Between the Sprinklers) for Horizontal Ceiling (mxm) (Max.2 inch Rise for 12 inch Run) MAXIMUM MINIMUM FLOW PRESSURE 12 x 12 12 ft. (3.7 x 3.7) (3.7 m) 13GPM (49.2LPM) 7.Opsi (0.050MPa) 14 x 14 14 ft. (4.3 x 4.3) (4.3 m) 9 ft. (2.7m) 14GPM (53.OLPM) 8.2psi (0.057MPa) 16 x 16 16 ft. 14GPM (53.OLPM) 8.2psi (0.057MPa) (4.9 x 4.9) (4.9 m) (a) For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. (b) Requirement is based on minimum flow in GPM/LPM from each sprinkler.The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. (c) ATentative Interim Amendment(TIA No.1028R)to the 2010 edition of NFPA 13D allows Horizontal Ceiling criteria to be used for certain Sloped Ceiling configurations up to 8/12 pitch. (d) For NFPA 13R applications, Horizontal Ceiling criteria may be used for sloped ceiling configurations up to 8/12 pitch when acceptable to the Local Authority Having Jurisdiction. Document No.0036785 Date : Nov/1912012 Page : 5 of 7 Sprinkler Spacing Criteria The minimum spacing between sprinklers is 9 feet (2.7m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref.Table A,B) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions. NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation is completed. The Protective Cap must be removed to place the sprinkler in service. Use a torque of 7 to 14 ft.lbs (9.5 to 19.ONm)to achieve a 112 inch NPT sprinkler joint.A maximum of 21 ft.lbs. (28.5 Nm) of torque is to be used to install sprinklers. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Installinq Procedure Step 1 The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch(50.8mm)as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling,the sprinkler installation can be started with the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Tolerance Limit of Ceiling Level' indicator on the Protective Cap to check for proper installation height(Ref. Figure 3). Make a Space Here Do NOT Ave./4`(6.4mm) Over—Tighten Groove on the S rinkler Min.%,(3.2mm) 1# E E Tolerance Limit Protective Ca o E of Ceilin Level N SCelling Ceiling Mounting Surface I Groove of the Socket Mounting Surface %� Socket Wrench 2- (060mm) Ceiling Hole Diameter CORRECT INCORRECT FIGURE 3. INSTALLATION FIGURE 4 Document No.0036785 Date : Nov/1912012 Page : 6 of 7 Step 4 Use the Cap Remover RC to remove the Protective Cap(Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm)air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Sprinkler Head Cu Protective Ca E E E Step o ® LJ E N /Ceiling Ceiling� II� -W Mounting Surface Cop Remover RC Screw Step 2 �.n u Cover Plate Assembly Hook by turning 2-a/a (�68mm) or 3-%4"(0 83.m) Step 3 or 2-5/"square((]68mm) Pull down FIGURE 5. PROTECTIVE CAP REMOVAL FIGURE 6 E E E +I E O O � N tl O N N /Ceiling Ceiling Ceiling INCORRECT CORRECT INCORRECT FIGURE 7. INSTALLATION(CORRECT OR INCORRECT) CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40 F14°C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. Document No.0036785 Date : Nov/1912012 Page : 7 of 7 If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting)brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds 100T/38°C. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified,they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages-before, during, and after installation. Damaged units, as a result of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor,the same coverage area,and the same or lower flow ratings(as indicated under Table A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls,first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA.Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing, its compliance with this documents,as well as the standards of the National Fire Protection Association(e.g., NFPA 25),and the regulations of any other authorities having jurisdiction.The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. ORDER PROCEDURE When placing an order,please contact a local distributor with the following information(Model Name, Specify,Temp.and Finish). Sprinkler: Model: RC-RES (SIN: SS8461, Residential Flat Concealed Sprinkler, Pendent, K4.9,Temperature: 162T (72°C)or 175T (79°C)) Cover Plate Assembly: 2-5/8 inch (0 68mm)or 3-1/4 inch (0 83mm)or 2-5/8 inch square(068mm), Order Separately from Sprinkler Finish White Painted Ivory Painted Nickel Plated Any Color Model Painted 140°F(60°C)Cover Plate for RC-RES 162°F or O O O O 162°F(72°C)Cover Plate for RC-RES 175°F "1: Choose one color of our acceptable color list. Regarding the color list information, please contact a local distributor. Tools for Installation of Model: RC-RES Socket for Model RC-RES Wrench&Socket for Model RC-RES Cap Remover RC Document No.0036785 Date : Nov/1912012 -WILKINS SPECIFICATION SUBMITTAL SHEET A ,.COMPANY Model 975XL Reduced Pressure Principle Assembly => APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contami- nated water into the potable water supply.Assembly shall FEATURES provide protection where a potential health hazard exists. Sizes: ❑ 3/4" ❑ 1" ❑ 11/4 ❑ 11/2 ❑ 2" Maximum working water pressure 175 PSI STANDARDS COMPLIANCE Maximum working water temperature 180°F ❑ ASSEO Listed 1013 Hydrostatic test pressure 350 PSI ❑ IAPMOO Listed End connections Threaded ANSI B1.20.1 ❑ ULO Classified(lessshut-off valves or with OS&Y valves) OPTIONS ❑ C-ULO Classified ❑ CSAO Certified (Suffixes can be combined) ❑ AWWA Compliant ❑ Approved by the Foundation for Cross Connection ❑ - with full port QT ball valves(standard) Control and Hydraulic Research at the University of ❑ L - less ball valves Southern California ❑ U - with union ball valves ❑ MS - with integral relief valve monitor switch ❑ P - for reclaimed water systems MATERIALS ❑ S - with bronze"Y"type strainer Main valve body Cast Bronze ASTM B 584 ❑ BMS - with battery operated monitor switch Access covers Cast Bronze ASTM B 584 ❑ FDC - with fire hydrant connection;2"only Fasteners Stainless Steel, 300 Series ❑ TCU - with test cocks up Elastomers Silicone (FDA Approved) ❑ V - with union swivel elbows Buna Nitrile (FDA Approved) ❑ SE - with street elbows Polymers NorylTM, NSF Listed ❑ RV - with test cocks supplied on the opposite side Springs Stainless steel, 300 series ❑ FT - with integral male 450 flare SAE test fitting ACCESSORIES E ❑ Air gap(Model AG) O / ❑ Repair kit(rubber only) o o ❑ Thermal expansion tank(Model WXTP) F o O o ❑ Soft seated check valve(Model 40) 0 0 ❑ Shock arrester(Model 1250) D c B A G DIMENSIONS&WEIGHTS(do not include pkg.) DIMENSIONS(approximate) WEIGHT MODEL SIZE A UNION A BALL BLESS BALL C D E F G LESS BALL WITH BALL VALVES VALVES VALVES VALVES in. mm in. mm in. I mm in. I mm in. I mm in. I mm in. I mm in. I mm in. I mm Ibs. ka Ibs. k 3/4 20 12 305 14 356 73/4 197 21/8 54 3 76 31/2 89 5 127 153/4 400 10 4.5 12 5.5 1 25 13 330 141/4 362 73/4 197 2 1/8 54 3 76 31/2 89 5 127 173/4 451 1 10 4.5 14 6.4 1 1/4 32 17 432 19 483 1015/16 278 23/4 70 31/2 89 5 127 63/4 171 22 559 22 10 28 12.7 1 1/2 40 17 3/8 441 20 508 1015/16 278 23/4 70 31/2 89 5 127 63/4 171 231/8 587 22 10 28 12.7 2 1 50 181/2 470 21 1/4 540 1015/16 278 23/4 70 J3 1/2 89 5 127 63/4 171 25 1/2 648 22 10 34 15.4 Pagel of 2 DocuMeBF 975XL(LG) RE V. FLOW CHARACTERISTICS Model 975XL 3/4" & 1" (STANDARD) a Model 975XL 11/4", 1'/2" &2" (STANDARD) a 3/4" 1.. a C6 � 11/4 11/2" 2" 15 15 0 0 W 10 W 10 cl: Cc I 5 0 20 40 60 80 ° 5 0 50 100 150 200 250 FLOW RATES(GPM) o FLOW RATES(GPM) Model 975XL 20mm &25mm (METRIC) Model 975XL 32mm,40mm &50mm (METRIC) al 150 a 150 32mm 40mm 50mm 120 2omm 25mm 120 Cn 0 90 90 cr cr n 60 Co 60 W W cr ir D 30 0 1 2 3 4 5 a 30 0 3 6 9 12 15 FLOW RATE(1/s) O Rated Flow FLOW RATE(1/s) (Established by approval agencies) TYPICAL INSTALLATION Capacity thru Schedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec Local codes shall govern installation requirements. To be 1/8" 1 1 2 3 installed in accordance with the manufacturers'instructions 1/a" 2 2 3 5 and the latest edition of the Uniform Plumbing Code. Un- 3/8" 3 4 6 9 less otherwise specified,the assembly shall be mounted at 1/2" 5 7 9 14 3/4" 8 12 17 25 a minimum of 12"(305mm)and a maximum of 30"(762mm) 1.1 13 20 27 40 above adequate drains with suff icient side clearance for test- 1 1/4" 23 35 47 70 ing and maintenance.The installation shall be made so that 1 1/2" 32 48 63 95 no part of the unit can be submerged. 2" 52 78 105 167 CENTRAL STATION ALARM PANEL PROTECTIVE ENCLOSURE II •II / II I I BATTERY MONITOR SWITCH a 12"MIN. 12"MIN 30"MAX. 30"MAX OPTIONAL AIR GAP AIR GAP WATER METER FITTING 0 o c o c DRAIN lu p FLOOR o / II II DIRECTION OF FLOW� II FLOOR DRAIN—� DIRECTION OF FLOW — INLET SHUT-OFF INDOOR INSTALLATION OUTDOOR INSTALLATION (Shown w/optional EMS) SPECIFICATIONS The Reduced Pressure Principle Backflow Preventer shall be ASSE®Listed 1013, rated to 180°F and supplied with full port ball valves.The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF®Listed NorylTM and the seat disc elastomers shall be silicone.The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter and integral monitor switch.The Reduced Pressure Principle Backflow Preventer shall be a WILKINS Model 975XL. Page 2 of 2 WILKINS OPERATION OF ZURN INDUSTRIES, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 11-2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com -WILKINS SPECIFICATION SUBMITTAL SHEET A ZURN COMPANY Model WXTP Water Thermal Expansion Tank APPLICATION Designed for installation on potable water lines between the backflow preventer or pressure reducing valve and the We— water heater to protect against water thermal expansion. When system pressure increases, water enters the tank's bladder which expands into the pre-charged air chamber, 0 keeping system pressure below the relief valve setting. STANDARDS COMPLIANCE ❑ IAPMO®Listed No FEATURES Sizes (liters): ❑ 8 ❑ 18 ❑ 32 MATERIALS ❑ 50V ❑ 75V ❑ 120V ❑ 165V Outer shell High Grade Steel ❑ 235V ❑ 320V Coatings Epoxy finish (outer shell) (V =vertical, free-standing) Connection Brass (sizes: 8 thru 32) Maximum working water pressure 150 PSI Stainless Steel (sizes: 50V thru 320V) Maximum working water temperature 200°F Bladder Butyl Rubber(FDA approved) Hydrostatic test pressure 350 PSI c— End connections Threaded NPT a = ANSI B1.20.1 Precharge(adjustable) 40 PSI ACCESSORIES ❑ BR4 - water pressure reducing valve B B ❑ TP1100A - temperature&pressure relief valve ❑ P1000A - pressure relief valve ❑ 975XL - reduced pressure backflow preventer c i A WXTP 5OV-320V WXTP 8-32 DIMENSIONS &WEIGHTS (do not include pkg.) TANK SPECIFICATIONS MODEL MAXIMUM TOTAL ACCEPTANCE FACTORY DIMENSIONS (INCHES) WEIGHT NUMBER WORKING VOLUME VOLUME PRECHARGE "A" "B" "C" (LBS) PRESSURE GALLONS (PSI) DIA. HEIGHT CONN. WXTP-8 150 PSIG 2.1 0.84 40 8.5 11.5 3/4' MNPT 7 WXTP-18 150 PSIG 4.5 1.8 40 10 15 3/4' MNPT 10 WXTP-32 150 PSIG 8.5 3.4 40 12.5 19.2 3/4' MNPT 15 WXTP-50V 150 PSIG 14 5.6 40 16 21.7 1" FNPT 32 WXTP-75V 150 PSIG 20 8.0 40 16 28.8 1" FNPT 39 WXTP-120V 150 PSIG 32 12.8 40 21 27.8 1" FNPT 60 WXTP-165V 150 PSIG 44 17.6 40 21 36.2 1'/4' FNPT 72 WXTP-235V 150 PSIG 62 24.8 40 21 47.9 1'/4' FNPT 112 WXTP-320V 150 PSIG 85 34.0 40 21 44.4 1'/4' FNPT 140 TEMPERATURE RANGE:33°F TO 200°F NOTE: RELIEF VALVE MUST BE SET AT 150 PSIG MAXIMUM Page1 of 2 DOCUMENT NO. REV. 9 WXT-WXTP 8/99 � � � � 1 � r�� ++�� '� r.'��... �: }��.` _ ., �, �..- �'.f '� y ! ���i I .�� ��- '�-✓r fi� �1- � � Kam. �� �� '� j Ill ' 1 11 � I 1 TABLE 2c. Dimensions and Physical Characteristics of Copper Tube:TYPE M Nominal Dimensions, inches Calculated Values(based on nominal dimensions) Nominal or Cross Weight Weight Contents of Tube Standard Outside Inside Wall Sectional of Tube Only, of Tube&Water, per linear ft Size,inches Diameter Diameter Thickness Area of Bore, pounds pounds Cu ft Gal s inches per linear ft per linear ft 3/8 .500 .450 .025 .159 .145 .214 .00110 .00826 '/2 .625 .569 .028 .254 .204 .314 .00176 .0132 3/4 .875 .811 .032 .517 .328 .551 .00359 .0269 1 1.125 1.055 .035 .874 .465 .843 .00607 .0454 1'/4 1.375 1.291 .042 1.31 .682 1.25 .00910 .0681 11/2 1.625 1.527 .049 1.83 .940 1.73 .0127 .0951 2 2.125 2.009 .058 3.17 1.46 2.83 .0220 .165 21/2 2.625 2.495 .065 4.89 2.03 4.14 .0340 .254 3 3.125 2.981 .072 6.98 2.68 5.70 .0485 .363 31/2 3.625 3.459 .083 9.40 3.58 7.64 .0653 .488 4 4.125 3.935 .095 12.2 4.66 9.83 .0847 .634 5 5.125 4.907 .109 18.9 6.66 14.8 .131 .982 6 6.125 1 5.881 1 .122 1 27.2 1 8.92 1 20.7 1 .189 1.41 8 8.125 7.785 .170 47.6 16.5 37.1 .331 2.47 10 10.125 9.701 .212 73.9 25.6 57.5 .513 3.84 12 12.125 11.617 .254 106 36.7 82.5 .736 5.51 TABLE 2d. Dimensions and Physical Characteristics of Copper Tube: DMV(Drain, Waste and Vent) Nominal Dimensions,inches Calculated Values(based on nominal dimensions) Nominal or Cross Weight Weight Contents of Tube Standard Outside Inside Wall Sectional of Tube Only, of Tube&Water, per linear ft Size,inches Diameter Diameter Thickness Area of Bore, pounds pounds s inches per linear ft per linear ft Cu ft Gal 1'/4 1.375 1.295 .040 1.32 .650 1.22 .00917 .0686 1'/Z 1.625 1.541 .042 1.87 .809 1.62 .0130 .0971 2 2.125 2.041 .042 3.27 1.07 2.48 .0227 .170 3 3.125 3.030 .045 7.21 1.69 4.81 .0501 .375 4 4.125 4.009 .058 11.6 2.87 7.88 .0806 .603 5 5.125 4.981 .072 19.5 4.43 12.9 .135 1.01 6 1 6.125 5.959 .083 27.9 6.10 18.2 .194 1.45 8 8.125 1 7.907 1 .109 49.1 1 10.6 1 31.8 1 .341 2.55 22 TABLE 3c. Rated Internal Working Pressure for Copper Tube: TYPE M* Annealed"" Drawn " Nominal S= S= S= S= S= S= S= S= S= S= S= S= S= S= Size,in 6000 psi 5100 psi 4900 psi 4800 psi 4700 psi 4000 psi 3000 psi 10,300 psi 10,300 psi 10,300 psi 10,300 psi 10,000 psi 9,700 psi 9,400 psi 100 F 150 F 200 F 250 F 300 F 350 F 400 F 100 F 150 F 200 F 250 F 300 F 350 F 400 F '/4 - s/s 570 485 466 456 447 380 285 982 982 982 982 953 925 896 '/2 494 420 403 395 387 329 247 850 850 850 850 825 800 776 5/8 3/4 407 346 332 326 319 271 204 701 701 701 701 680 660 639 1 337 286 275 270 264 225 169 580 580 580 580 563 546 529 1'/4 338 287 276 271 265 225 169 582 582 582 582 565 548 531 1'/2 331 282 270 265 259 221 166 569 569 569 569 553 536 520 2 299 254 244 239 234 199 149 514 514 514 514 499 484 469 21/2 274 233 224 219 215 183 137 471 471 471 471 457 444 430 3 253 215 207 203 199 169 127 435 435 435 435 423 410 397 31/2 252 214 206 202 197 168 126 433 433 433 433 421 408 395 4 251 213 205 201 197 167 126 431 431 431 431 419 406 394 5 233 198 190 186 182 155 116 400 400 400 400 388 377 365 6 218 186 178 175 171 146 109 375 375 375 375 364 353 342 8 229 195 187 183 180 153 115 394 394 394 394 382 371 359 10 230 195 188 184 180 153 115 394 394 394 394 383 371 360 12 230 195 188 184 180 153 115 395 395 395 395 383 372 360 TABLE 3d. Rated Internal Working Pressure for Copper Tube: DWV* Annealed" Drawn' Nominal S= S= S= S= S= S= S= S= S= S= S= S= S= S= Size,in 6000 psi 5100 psi 4900 psi 4800 psi 4700 psi 4000 psi 3000 psi 10,300 psi 10,300 psi 10,300 psi 10,300 psi 10,000 psi 9,700 psi 9,400 psi 100 F 150 F 200 F 250 F 300 F 350 F 400 F 100 F 150 F 200 F 250 F 300 F 350 F 400 F 1'/4 330 280 269 264 258 220 165 566 566 566 566 549 533 516 1'/2 1 293 249 240 235 230 196 147 503 503 503 503 489 474 459 2 217 185 178 174 170 145 109 373 373 373 373 362 352 341 3 159 135 130 127 125 106 80 273 273 273 273 265 257 249 4 150 127 122 120 117 100 75 257 257 257 257 250 242 235 5 151 129 124 121 119 101 76 260 260 260 260 252 245 237 6 148 126 121 119 116 99 74 255 255 255 255 247 240 232 8 146 124 119 117 114 97 73 1 251 251 251 251 244 236 229 NOTE: 'Based on maximum allowable stress in tension (psi)for the indicated temperatures ff),see page 12. *When brazing or welding is used to join drawn tube,the corresponding annealed rating must be used,see page 12. "*"Types M and DWV are not normally available in the annealed temper.Shaded values are provided for guidance when drawn temper tube is brazed or welded,see page 12. 26 Wrot & Cast Pressure Fittings Tees WROT CAST WROT CAST 111 Tee 4711 111 Tee-cont. 4711 Copper to Copper to Copper Copper to Copper to Copper Nominal Size Box Master Approx. Dim. Dim. Dim. In Inches Quantity Pack Net Wt. A B C 3/4 x 3/4 x 1/2 25 250 0.109 25/64 25/64 19/32 3/4 x 3/4 x 3/8 25 250 0.130 25/64 25/64 11/16 3/4 x 3/4 x 1/4 25 250 0.135 25/64 25/64 3/4 ET + *3/4 x 5/8 x 5/8 25 250 0.150 1/2 11/16 3/4 3/4 x 1/2 x 3/4 25 250 0.144 1/2 25/32 17/32 C x C x C �A'i'B- 3/4 x 1/2 x 1/2 25 250 0.109 25/64 5/8 19/32 *3/4 x 1/2 x 3/8 25 250 0.137 25/64 5/8 11/16 3/4 x 1/2 x 1/4 25 250 0.140 25/64 5/8 3/4 Nominal Size Box Master Approx. Dim. Dim. Dim. *3/4 x 3/8 x 3/4 25 250 0.159 1/2 29/32 17/32 In Inches Quantity Pack Net Wt. A B C *3/4 x 3/8 x 1/2 25 250 0.140 25/64 23/32 19/32 1/8 50 1000 0.014 13/64 13/64 7/32 *3/4 x 3/8 x 3/8 25 250 0.132 25/64 23/32 11/16 5/16 OD 50 1000 0.020 7/32 7/32 9/32 1 x 1 x 1 1/2 5 50 0.680 1 1/4 1 1/4 1 5/32 1/4 50 1000 0.028 17/64 17/64 1/4 1 x 1 x 1 1/4 5 50 0.405 1 5/32 1 5/32 31/32 3/8 50 500 0.045 5/16 5/16 3/8 1 x 1 x 3/4 10 100 0.223 1/2 1/2 5/8 1/2 50 500 0.056 21/64 21/64 11/32 *1 x 1 x 5/8 10 100 0.319 1/2 1/2 15/16 5/8 25 250 0.110 7/16 7/16 1/2 1 x 1 x 1/2 10 100 0.186 23/64 23/64 11/16 3/4 25 250 0.144 1/2 1/2 17/32 1 x 1 x 3/8 10 100 0.185 23/64 23/64 13/16 1 10 100 0.291 21/32 21/32 21/32 1 x 3/4 x 1 10 100 0.290 21/32 53/64 21/32 1 1/4 5 50 0.397 41/64 41/64 41/64 1 x 3/4 x 3/4 10 100 0.220 1/2 11/16 5/8 1 1/2 5 50 0.540 13/16 13/16 13/16 1 x 3/4 x 112 10 100 0.185 23/64 9/16 11/16 2 5 40 1.082 1 1/16 1 1/16 1 15/64 *1 x 3/4 x 3/8 10 100 0.270 23/64 9/16 13/16 21/2 1 10 1.967 1 21/32 1 21/32 1 11/16 *1 x 5/8 x 5/8 10 100 0.313 1/2 11/16 15/16 3 1 10 2.744 1 7/8 1 7/8 1 11/16 *1 x 5/8 x 1/2 10 100 0.272 23/64 9/16 11/16 31/2 1 8 4.167 25/32 25/32 21/4 1 x 1/2 x 1 10 100 0.290 21/32 5/64 21/32 4 1 8 6.396 213/32 213/32 29/16 1 x 1/2 x 3/4 10 100 0.220 1/2 15/16 5/8 -5 1 1 7.998 237/64 237/64 229/32 1 x 1/2 x 1/2 10 100 0.185 23/64 13/16 11/16 -6 1 1 12.613 31/8 31/8 311/16 1 x 1/2 x 3/8 10 100 0.185 23/64 13/16 13/16 -8 1 1 32.086 41/16 4 1/16 43/4 1 1/4 x 1 1/4 x 2 5 40 1.352 1 3/4 1 3/4 1 3/8 *3/8 x 3/8 x 3/16 OD 50 1000 0.028 17/64 17/64 7/16 1 1/4 x 1 1/4 x 1 1/2 5 50 0.680 1 3/16 1 3/16 1 5/32 1/8 x 1/8 x 1/4 50 1000 0.028 13/32 13/32 1/4 1 1/4 x 1 1/4 x 1 5 50 0.348 17/32 17/32 25/32 1/4 x 1/4 x 1/2 50 500 0.063 21/32 21/32 11/32 1 1/4 x 1 1/4 x 3/4 5 50 0.301 7/16 7/16 3/4 1/4 x 1/4 x 3/8 50 500 0.045 15132 15/32 3/8 1 1/4 x 1 1/4 x 1/2 5 50 0.259 19/64 19/64 11/16 1/4 x 1/4 x 1/8 50 1000 0.028 17/64 17/64 13/32 1 1/4 x 1 x 1 1/4 5 50 0.405 7/8 7/8 25/32 1/4 x 1/8 x 1/4 50 1000 0.028 17/64 13/32 1/4 1 1/4 x 1 x 1 5 50 0.391 3/4 3/4 25/32 1/4 x 1/8 x 1/8 50 1000 0.028 17/64 13/32 13/32 1 1/4 x 1 x 3/4 5 50 0.297 5/8 5/8 25/32 3/8 x 3/8 x 1/2 50 500 0.063 17/32 17/32 11/32 1 1/4 x 1 x 1/2 5 50 0.256 1/2 1/2 25/32 3/8 x 3/8 x 1/4 50 500 0.045 5/16 5/16 15/32 1 1/4 x 3/4 x 1 1/4 5 50 0.405 7/8 7/8 25/32 3/8 x 3/8 x 1/8 50 500 0.045 5/16 5/16 39/64 1 1/4 x 3/4 x 1 5 50 0.391 3/4 3/4 25132 *3/8 x 1/4 x 1/2 50 500 0.063 17/32 21/32 11/32 1 1/4 x 3/4 x 3/4 5 50 0.297 5/8 5/8 25/32 3/8 x 1/4 x 1/4 50 500 0.045 5/16 15/32 15/32 1 1/4 x 3/4 x 1/2 5 50 0.256 1/2 1/2 25/32 *3/8 x 1/4 x 1/8 50 500 0.045 5/16 15/32 5/8 1 1/4 x 1/2 x 1 1/4 5 50 0.405 7/8 7/8 25/32 3/8 x 1/8 x 3/8 50 500 0.045 5/16 9/16 3/8 **1 1/4 x 1/2 x 1 12 72 0.470 - - 1/2 x 1/2 x 1 10 100 0.290 15/16 15/16 3/4 1 1/2 x 1 1/2 x 2 5 50 1.352 1 37/64 1 37/64 1 3/8 1/2 x 1/2 x 3/4 25 250 0.118 33/64 33/64 15/32 1 1/2 x 1 1/2 x 1 1/4 5 50 0.482 11/16 11/16 13/16 1/2 x 1/2 x 3/8 50 500 0.061 5/16 5/16 13/32 1 1/2 x 1 1/2 x 1 5 50 0.387 9/16 9/16 13/16 1/2 x 1/2 x 1/4 50 500 0.061 9/32 9/32 13/32 1 1/2 x 1 1/2 x 3/4 5 50 0.342 7/16 7/16 13/16 1/2 x 1/2 x 1/8 50 500 0.061 9/32 9/32 1/2 1 1/2 x 1 1/2 x 1/2 5 50 0.310 21/64 21/64 29/32 1/2 x 3/8 x 1/2 50 500 0.063 3/8 17/32 11/32 1 1/2 x 1 1/4 x 1 1/2 5 50 0.680 1 7/32 1 3/16 1 7/32 1/2 x 3/8 x 3/8 50 500 0.061 5/16 1/2 13/32 1 1/2 x 1 1/4 x 1 1/4 5 50 0.661 31/32 1 3/16 1 1/16 1/2 x 1/4 x 1/4 50 500 0.061 9/32 5/8 13/32 1 1/2 x 1 1/4 x 1 5 50 0.591 27/32 1 3/16 1 1/16 3/4 x 3/4 x 1 10 100 0.202 3/4 3/4 17/32 1 1/2 x 1 1/4 x 3/4 5 50 0.583 11/16 7/8 31/32 *3/4 x 3/4 x 5/8 25 250 0.153 1/2 1/2 3/4 1 1/2 x 1 1/4 x 1/2 5 50 0.460 9/16 13/16 31/32 "'Cast Bronze Only 'Factory Option-consult factory for price and delivery information. Elkhart Products Corporation 11 Wrot & Cast Pressure Fittings Elbows WROT CAST WROT CAST 105-L 900 Street Elbow-Long Turn 106-2 450 Street Elbow Fitting to Fitting Fitting to Copper A� B A FfG.x FTG. FTG.x C A Nominal Size Box Master Approx. Dim. Dim. In Inches Quantity Pack Net Wt. A B Nominal Size Box Master Approx. Dim. 1/4 50 1000 0.013 15/64 41/64 In Inches Quantity Pack Net Wt. A 3/8 50 1000 0.024 9/32 23/32 3/8 25 500 0.033 13/16 1/2 100 1000 0.035 5/16 25/32 1/2 25 250 0.056 17/16 5/8 25 250 0.059 27/64 11/16 3/4 25 250 0.12 2 3/4 50 500 0.076 13/32 13/16 1 10 100 0.224 215/32 1 25 250 0.134 7/16 17/16 1 1/4 5 50 0.388 229/32 1 1/4 25 200 0.229 17/32 1 9/16 1 1/2 5 50 0.560 35/16 1 1/2 20 160 0.343 19/32 1 3/4 2 5 40 1.156 43/8 2 10 80 0.625 25/32 23/16 21/2 5 40 0.965 29/32 27/16 3 3 24 1.470 1 211/16 WROT CAST `31/2 1 16 2.100 15/32 3 106 450 Elbow 4 1 8 3.340 19/32 31/2 Copper to Capper WROT CAST 107-C 900 Elbow-Close Ruff 4707 Copper to Copper 4 B E P°IC � y C x C � -- R A t A CxC Nominal Size Box Master Approx. Dim. In Inches Quantity Pack Net Wt. A Nominal Size Box Master Approx. Dim. Dim. 1/4 50 1000 0.013 15/64 In Inches Quantity Pack Net Wt. A B 3/8 50 1000 0.024 1/4 1/8 50 1000 0.006 1/4 1/4 1/2 100 1000 0.036 17/64 1/4 50 1000 0.012 3/8 318 5/8 25 250 0.063 7/16 318 50 1000 0.026 13/32 13132 3/4 50 500 0.077 3/8 1/2 100 1000 0.039 25/64 25/64 1 25 250 0.137 13/32 5/8 25 250 0.069 17/32 17/32 11/4 25 200 0.229 33/64 3/4 50 500 0.087 9/16 9/16 11/2 20 160 0.343 19/32 1 20 200 0.168 47/64 47/64 2 10 80 0.625 25/32 11/4 25 200 0.300 15116 15116 21/2 5 40 0.970 7/8 11/2 20 120 0.404 111/64 111/64 3 3 24 1.460 63/64 2 10 80 0.748 129/64 129/64 31/2 1 16 2.180 15/32 21/2 5 40 1.200 121/32 121/32 4 1 8 3.376 111/64 3 3 24 1.920 161/64 161/64 5 1 6 6.564 1 13/32 31/2 1 8 2.728 27/32 27/32 6 1 1 11.200 1 11/16 4 1 8 4.290 217/32 217/32 8 1 1 27.900 21/4 5 1 1 8.586 31/8 31/8 6 1 1 15.200 313116 313/16 8 1 1 37.000 51/8 51/8 8 Elkhart Products Corporation A subsidiary of Amcast Industrial Corporation "`Cast Bronze Only *Factory Option-consult factory for price and delivery information. Wrot & Cast Pressure Fittings Couplings WROT CAST WROT CAST 100 Coupling With Stop 101 Coupling Without Stop-cont. Copper to Copper Copper to Copper Nominal Size Box Master Approx. Dim. A-1 I~ In Inches Quantity Pack Net Wt. A 21/2 5 50 0.616 31/32 EIA 3 5 40 0.912 313/32 C x C 31/2 1 16 1.352 329/32 4 2 16 1.878 413/32 5 1 6 3.365 51/2 6 1 6 5.262 63/8 Nominal Size Box Master Approx. Dim. 8 1 1 12.941 81/4 In Inches Quantity Pack Net Wt. A 3/160D 50 1000 0.002 1/16 5/160D 50 1000 0.006 1/16 1/8 50 1000 0.004 1/16 WROT CAST 1/4 50 1000 0.007 3/32 101-R Coupling With Stop 4701-R 3/8 50 1000 0.014 3/32 Copper to Copper 1/2 100 1000 0.021 3/32 5/8 25 500 0.040 3/32 3/4 50 500 0.048 3/32 7/8 10 200 0.084 3/32 A 1 25 250 0.088 3/32 ` 11/4 20 200 0144 3132 1 1/2 10 100 0.216 3/32 1 E PC 2 5 50 0.391 3/32 21/2 5 50 0.624 3/32 C x C Eal 3 5 40 0.909 3/32 31/2 1 16 1.369 3/32 4 2 16 1.904 3132 5 1 6 3.365 3/16 Nominal Size Box Master Approx. Dim. 6 1 6 5.262 3/16 In Inches Quantity Pack Net Wt. A 8 1 1 12.941 1/8 1/40D x 3/16 OD 50 1000 0.004 3/32 3/80D x 5/16 OD 50 1000 0.008 3/32 1/4 x 1/8 50 1000 0.008 5/32 WROT CAST 3/8 x 1/4 50 1000 0.017 3/16 3/8 x 1/8 50 1000 0.019 1/4 101 Coupling Without Stop 1/2x3/8 50 1000 0.026 5/32 Copper to Copper 1/2 x 1/4 50 1000 0.024 1/4 1/2 x 1/8 50 1000 0.025 23/64 5/8 x 1/2 25 500 0.035 5/32 A -{ 5/8 x 3/8 25 500 0.036 7/32 5/8 x 1/4 25 500 0.043 5/16 EP 3/4 x 5/8 50 500 0.066 3/16 3/4 x 1/2 50 500 0.061 3/16 3/4 x 3/8 50 500 0.052 21/64 C x C 3/4 x 1/4 50 500 0.053 7/16 1 x 3/4 25 250 0.098 13/32 1 x 5/8 25 250 0.102 3/8 Nominal Size Box Master Approx. Dim. 1 x 1/2 25 250 0.104 7/16 In Inches Quantity Pack Net Wt. A 1 x3/8 25 250 0.093 1/2 1 1/4 x 1 10 100 0.152 5/16 1/4 50 1000 0.006 23/32 1 1/4 x 3/4 10 100 0.134 15/32 3/8 50 1000 0.013 55/64 1 1/4 x 1/2 10 100 0.165 41/64 1/2 100 1000 0.019 1 3/32 1 1/2 x 1 1/4 10 100 0.220 11/32 3/4 50 500 0.046 1 19/32 1 1/2 x 1 10 100 0.220 7/16 1 25 250 0.087 1 29/32 1 1/2 x 3/4 10 100 0.218 21/32 1 1/4 20 200 0.149 21/32 1 1/2 x 1/2 10 100 0.219 25/32 1 1/2 10 100 0.213 217/64 2 x 1 1/2 10 100 0.366 13/32 2 5 50 0.391 249/64 4 Elkhart Products Corporation A subsidiary of Amcast Industrial Corporation "`Cast Bronze Only *Factory Option-consult factory for price and delivery information. Wrot & Cast Pressure Fittings Adapters WROT CAST WROT CAST 103 Female Adapter 4703 103-2 Female Street Adapter 4703-2 Copper to Female N.P.T. Fitting to Female N.P.T. A A y n} EE FTG.x F L==U Nominal Size Box Master Approx. Dim. In Inches Quantity Pack Net Wt. A C x F 1/4 50 1000 0.030 29/32 3/8 50 1000 0.049 11/16 1/2 50 500 0.084 1 3/8 Nominal Size Box Master Approx. Dim. 3/4 25 250 0.143 1 11/16 In Inches Quantity Pack Net Wt. A 1 20 200 0.214 131/32 1 1/4 10 100 0.324 25/32 1/8 50 1000 0.029 7/16 1 1/2 10 100 0.437 27/16 1/4 50 1000 0.031 15/32 2 5 50 0.641 219/32 3/8 50 500 0.053 19/32 '*21/2 25 25 1.740 - 1/2 50 500 0.086 7/8 **3 20 20 2.470 - 3/4 25 250 0.143 23/32 1/2 x 3/8 50 500 0.062 1 1/8 1 20 200 0.226 31/32 1/2 x 1/4 50 500 0.041 59/64 1 1/4 10 100 0.304 1 3/32 **3/4 x 1/2 25 225 0.147 - 1 1/2 10 100 0.404 1 5/32 **1 x 3/4 25 250 0.414 2 5 50 0.650 1 1/4 **1 x 1/2 25 250 0.153 21/2 2 20 1.228 1 1/2 **3 12 12 2.400 **4 12 12 3.820 **5 6 6 8.250 WROT CAST **6 4 4 12.000 104 Male Adapter 4704 1/8 x 1/4 50 1000 0.033 1/2 Copper to Male N.P.T. 1/4 x 1/2 50 500 0.078 25/32 1/4 x 318 50 1000 0.043 21/32 1/4 x 1/8 50 1000 0.024 11/32 ~A-1 3/8 x 1/2 50 500 0.082 7/8 3/8 x 1/4 50 1000 0.041 15/32 **1/2 x 1 25 150 0.300 - 1/2 x 3/4 25 250 0.121 29/32 C x M 1/2 x 3/8 50 500 0.046 9/16 1/2 x 1/4 50 500 0.044 15/32 Nominal Size BOX Master Approx. Dim. 5/8x3/4 25 250 0.143 1 In Inches Quantity Pack Net Wt. A 5/8 x 1/2 25 250 0.102 3/4 **3/4 x 1 1/4 10 100 0.515 - 1/8 50 1000 0.0187 13/32 3/4 x 1 20 200 0.218 1 7/32 1/4 50 1000 0.027 15/32 3/4 x 1/2 25 250 0.085 19/32 3/8 50 500 0.041 7/8 **1 x 1 1/2 10 100 0.720 - 1/2 50 500 0.064 19/32 1 x 1 1/4 10 100 0.299 1 7/32 3/4 25 250 0.119 13/16 1 x 3/4 25 250 0.159 43/64 1 20 200 0.160 27/32 1 x 1/2 10 100 0.239 11/16 1 1/4 10 100 0.317 15/16 **1 1/4 x 2 5 50 0.980 1 1/2 10 100 0.443 7/8 1 1/4 x 1 1/2 10 100 0.431 1 19/64 2 5 50 0.675 1 11/32 1 1/4 x 1 10 100 0.238 55/64 2 1/2 4 40 1.267 1 21/32 **1 1/4 x 3/4 100 100 0.290 3 2 20 2.138 1 25/32 1 1/2 x 2 5 50 0.678 1 7/16 4 1 16 3.500 1 29/32 1 1/2 x 1 1/4 10 100 0.388 7/8 **5 5 5 8.600 **1 1/2 x 1 60 60 0.370 **6 4 4 10.730 2 x 1 1/2 5 50 0.730 13/16 1/8 x 3/8 50 1000 0.040 3/4 6 Elkhart Products Corporation A subsidiary of Amcast Industrial Corporation **Cast Bronze Only *Factory Option-consult factory for price and delivery information. Catalog 2001 HANGERS & FASTENERS WMI PADLOCK TM Tube Strap • Isolates tube from surface to reduce noise transfer. • Extra strong—seam is secured by nail or screw. • Will not damage tube if over-driven. • Allows tube to expand and contract. • Fits and fastens to our Grid Iron bracket! 4$j Fast installations—The Padlock snaps onto tube and fastens to surface with nail or screw. Specifications Item Bag Mstr List Nail Rust resistant,zinc plated yellow irradite No. Description Qty, Crtn Price continuous ring-shank #8 x 13/,11 or#8 x 21/2"zinc plated, 551-P2 1/2" CTS Padlock-preloaded nail 100 1000 10.50/c Screw pierce point 1/,"hex/washer,combo head 551-P3 3/4" CTS Padlock with preloaded nail 50 500 15.50/c High Density Polyethylene Hanger Ultra-Violet protected 551-P2S 1/2" CTS Padlock with preloaded screw 100 1000 30.00/c Impact resistant to o IF(-18 T). Body Max.Temp:160 IF 171°C)continuous. 551-P3S 3/4" CTS Padlock with preloaded screw 1 50 1 500 1 35.00/c (Do not use when water temp exceeds 160°F) SIOUX STRApTM Tube Hanger Patent#4,260,123 • Allows tube to expand and contract without loosening. • Sioux Straps are 100% corrosion proof. • Tube is not damaged if nail is over driven. The Sioux Strap insulates and isolates the tube from mounting surface, reducing noise transfer. Ring-shank nails assure a permanent hold. Ivory colored models for professional looking CPVC installations. Item Description Bag Mstr List No. Qty. Crtn Price 551-2 1/2" CTS Sioux Strap-preloaded nail 100 1000 10.50c Specifications 551-2C Ivory color#551-2 for CPVC 100 1000 10.50c Rust resistant,zinc plated yellow irradite Nail continuous ring-shank 551-3 3/4" CTS Sioux Strap-preloaded nail 50 500 15.50c 551-3C Ivory color#551-3 for CPVC 50 500 15.50c Screw #8 x 2 /2",zinc plated,"A"point /,"hex/washer,slotted head 551-4 1" CTS Sioux Strap-preloaded nail 25 250 30.00c High Density Polyethylene Hanger Ultra-Violet protected 551-4C Ivory color#551-4 for CPVC 25 250 30.00c Impact resistant to 0 IF(-18°C). Body Max.Temp:160 IF(71°C)continuous. 551-4S 1" CTS Sioux Strap-preloaded screw 25 250 48.50c (Do not use when water temp exceeds 160°F) Sioux Chief Manufacturing • tel: 1-800-821-3944 • www.siouxchief.com • fax: 1-800-758-5950 3 HANGERS & FASTENERS Catalog 2001 PIPE EYETM Metal Stud Insert Grommet • Fits 1 318" or 1 11132" holes in metal studs. • Split design. Offset hole for adjustable tube position. Item Nominal Bag Mstr List Price - No. CTS Size Qty. Crtn Each High Density Polyethylene 558-M2 1/2" 100 1000 .18 Ultra-Violet protected Impact resistant to 0 IF(-18°C). 558-M3 3/4" 100 1000 .20 Max.Temp:160 IF(71°C)continuous. (Do not use when water temp exceeds 160°F) I 558-E4 1" 25 1 250 1 .30 SUSPENSION CLAMP • Great as a grommet through studs or joists. • Split design for pre-piped CTS piping. Item Nominal Bag Mstr List Price ® No. CTS Size Qty. Crtn Each 557-2 1/2" 100 1000 .19 Specifications ® 557-3 3/4" 100 1000 .20 Super High Impact Polypropylene 557-4 1" 50 500 .56 Impact resistant to 0 IF(-18°C). Safe working load:15 lbs. 5 557-5 1-1/4" 25 250 .87 175 OF(79°C)continuous. , Max.Temp: 185 OF(85°C)intermittent. 557 6 11/2" 25 250 1.00 (Not for use on copper heat recirculating lines) 557-7 1 2" 1 25 1 250 1.20 TUBE INSULATOR • Insulates tube in wood or metal studs. • 13/8" hole required. • Split design for pre-piped CTS piping. Specifications I Item Nominal Bag Mstr List Price Low Density Polyethylene No. CTS Size Qty. Crtn Each Impact resistant to 0 IF(-18°C). 558-2 1/2" 50 500 .33 Max.Temp: 175 OF(79°C)continuous. 185 IF(85°C)intermittent. i'...: 558-3 3/4" 50 500 .34 (Not for use on copper heat recirculating lines) i1 � ' 558-4 1" 25 250 .36 TUBE CLAMP • Split design for pre-piped CTS piping. Item Nominal Bag Mstr List Price No. CTS Size Qty. Crtn Each 559-2 1/2" 100 1000 .19 Specifications t� 559-3 3/4" 100 1000 .20 Super High Impact Polypropylene 559-4 1" 50 500 .46 Impact resistant to °F °C). \ t ` 559-5 1-1/4" 25 250 .63 Safe working load: lb:15 lbs. 1 175 IF(79°C)continuous. Max.Temp: \ \ \ 559-6 11/2" 25 250 .78 185 IF(85°C)intermittent. (Not for use on copper heat recirculating lines) \ 1 559-7 2" 25 1 250 1.00 IL 4 Sioux Chief Manufacturing • tel: 1-800-821-3944 • www.siouxchief.com • fax: 1-800-758-5950