HomeMy WebLinkAboutB13-0153 Engineering Letter and Shop Drawing approvedISTRUCTURAL DESIGN 65 N4th ST,SUITE 5 CARBONDALE,CO 81623 (970)618-7708 (970)963-0265 -FAX 29029 UPPER BEAR CRK RD,#308 EVERGREEN.CO 80439 (303)670-0028 -phlfax (720)626-920'-cell wW\V,evolvestruct.com June 3,2013 Isaac Ellis Sunsense Inc. P.O.Box 301 Carbondale,CO 81623 RE:PV Panei Addition at the Pierce Residence 2730 Bald Mountain Road Vail,CO 81657 Dear Isaac: As requested we have reviewed the proposed photo voltaic panel addition at the residence noted above.Our analysis is based upon the original drawings and specifications provided by Sunsense on ApAllO.2013.as well as the attached updated layout dated June 3,2013.We have also reviewed the existing roof framing based upon existing structural drawings provided by Venture Architecture,designed by Engineering Designworks dated April 4,2012.The existing conditions shall be verified by contractor prior to construction.We shall be notified if conditions are found to differ from that shown on the referenced set of existing structural drawings or as stated within. The applicable current codes are the 2012 International Residential Code and the 2012 International Building Code per the Town of VaiL The applicable structural design criteria are as follows: Roof Dead Load Roof Snow Load Wind Criteria 20 psf'(assumed,including 3 psfPV panel &rack) 80 psf at modified roof area (7:12 wi slippery surface at panels) 90 mph,Exposure B The existing roof framing is assumed to be 5/8"APA rated sheathing,40/20,spanning perpendicular over 11 718"I-joist or LVL rafters,spaced at a maximum of24"0.c.The sheathing is assumed to be attached to the rafters with 8d common nails at 6"0.c.at panel edges and at 12"0.c.to intermediate framing members.The design of the panels,the panel racks and connections between shall be per the manufacturer for the applicable design criteria.For the layout and attachment of the racks to the roofrefer to the Sunsense Fastening Layout on P-OS,dated AprilB,2013.Orion EZ Roof Mount L- Foot Kit for shingle roofs shall be used for the connections to the existing roof,installed per manufacturer.Each circular base plate shall be attached with (4)#12 x 2 W'Dekfast screws.Screws shall have a minimum y.,"through sheathing penetration and (2)screws shall penetrate an existing rafter 12"minimum.The center ofthe L-Foot base plates shall be located over the rafters.with a maximum tolerance of 1 \/,"to the center of rafter. Per the design criteria,assumptions and recommendations stated above,it is our professional opinion that the existing roof structure is adequate for the proposed PV panel addition. Should you have any further questions regarding this matter,please feel free to contact our office. Sincerely, Evolve Structural Design LLC Sara Mickus,P.E. Principal ~8J II I 1 "l> I (J)-;w~~mr1I~~ZIr I h}-z:;G)~ II r I ~l> I -<II 0iCIi-I I1 I IT I I I 1 I\ i !I I--------1 !I~-+I~I~+!I-+-+--~--~--4-4---~ 1 \/I I I J:~~I -+i ~I -+-+!-+4-~~~~I i I i Ii i I I J /~~I 0C!!.JfJ!Jf3@G[JI;3[3 SOLAR I DESIGN I BUilD PIERCE RESIDENCE 6.24 kW Photovoltaic System NOTES: 1)Roof Structure:12"TJI-24"OC 2)Roof Material:Wood Shingle 3)Racking System:P8 Power Rail SITE ADDRESS:2730 Bald Mountain Rd. Vail,CO 81657 REVISION:C DATE:6/3/13 DRAWN BY:IJEP.O.Box 301 Carbondale,CO 81623 P 970.963.1420 F 970.963.1496