HomeMy WebLinkAboutB13-0238 Plans approvedTo
L
o
a
d
s
CONDUCT
O
R
S
E
X
P
O
S
E
D
T
O
F
R
E
E
A
I
R
(4) 10 AW
G
R
H
W
/
U
S
E
-
2
C
O
N
D
U
C
T
O
R
S
(1
)
6
A
W
G
B
A
R
E
C
U
G
R
O
U
N
D
3/4
"
E
M
T
O
R
E
Q
U
I
V
A
L
E
N
T
(4
)
1
0
A
W
G
T
H
H
N
/
T
H
W
N
-
2
C
O
N
D
U
C
T
O
R
S
(1
)
1
0
A
W
G
T
H
H
N
/
T
H
W
N
-
2
G
R
O
U
N
D
1"
E
M
T
O
R
E
Q
U
I
V
A
L
E
N
T
(3
)
8
A
W
G
T
H
H
N
/
T
H
W
N
-
2
C
O
N
D
U
C
T
O
R
S
(1
)
8
A
W
G
T
H
H
N
/
T
H
W
N
-
2
G
R
O
U
N
D
1
23
4
6
2
1
3
4
6
EX
I
S
T
I
N
G
CO
N
D
U
I
T
A
N
D
CO
N
D
U
C
T
O
R
S
EQ
U
I
P
M
E
N
T
S
C
H
E
D
U
L
E
PV
A
r
r
a
y
I
n
f
o
r
m
a
t
i
o
n
Nu
m
b
e
r
o
f
M
o
d
u
l
e
s
i
n
S
e
r
i
e
s
=
1
2
Nu
m
b
e
r
o
f
M
o
d
u
l
e
s
i
n
P
a
r
a
l
l
e
l
=
2
Ra
t
e
d
M
P
P
C
u
r
r
e
n
t
=
1
6
.
6
A
Ra
t
e
d
M
P
P
V
o
l
t
a
g
e
=
3
7
5
.
6
V
Ma
x
S
y
s
t
e
m
V
o
l
t
a
g
e
=
5
3
5
.
1
3
V
Sh
o
r
t
C
i
r
c
u
i
t
C
u
r
r
e
n
t
=
1
7
.
5
2
A
PV
M
o
d
u
l
e
R
a
t
i
n
g
@
S
T
C
PV
M
o
d
u
l
e
M
a
n
u
f
a
c
t
u
r
e
r
=
A
L
E
O
PV
M
o
d
u
l
e
M
o
d
e
l
=
S
7
9
U
2
6
0
Ma
x
P
o
w
e
r
C
u
r
r
e
n
t
(
I
m
p
)
=
8
.
3
A
Ma
x
P
o
w
e
r
V
o
l
t
a
g
e
(
V
m
p
)
=
3
1
.
3
V
Op
e
n
C
i
r
c
u
i
t
V
o
l
t
a
g
e
(
V
o
c
)
=
3
8
.
2
V
Sh
o
r
t
C
i
r
c
u
i
t
C
u
r
r
e
n
t
(
I
s
c
)
=
8
.
7
6
A
Ma
x
S
e
r
i
e
s
F
u
s
e
(
O
C
P
D
)
=
1
5
A
Ma
x
P
o
w
e
r
(
P
m
a
x
,
S
T
C
)
=
2
6
0
W
Ma
x
S
y
s
t
e
m
V
o
l
t
a
g
e
=
6
0
0
V
Vo
c
T
e
m
p
.
C
o
e
f
f
i
c
i
e
n
t
=
-
.
3
1
%
/
K
Pa
s
s
t
h
r
o
u
g
h
B
o
x
WIL
E
Y
-
A
C
E
2
P
In
v
e
r
t
e
r
In
v
e
r
t
e
r
M
a
n
u
f
a
c
t
u
r
e
r
=
S
M
A
In
v
e
r
t
e
r
M
o
d
e
l
#
=
S
B
6
0
0
0
-
U
S
Ma
x
D
C
V
o
l
t
a
g
e
R
a
t
i
n
g
=
6
0
0
V
Ma
x
P
o
w
e
r
=
6
0
0
0
W
No
m
i
n
a
l
A
C
V
o
l
t
a
g
e
=
2
4
0
V
Ma
x
A
C
C
u
r
r
e
n
t
=
2
5
A
@
2
4
0
V
A
C
In
t
e
g
r
a
t
e
d
F
u
s
e
d
D
C
D
i
s
c
o
n
n
e
c
t
AC
D
i
s
c
o
n
n
e
c
t
NE
M
A
3
R
Ex
i
s
t
i
n
g
S
e
r
v
i
c
e
20
0
A
B
u
s
b
a
r
/
2
0
0
A
M
a
i
n
12
0
/
2
4
0
S
p
l
i
t
P
h
a
s
e
S
e
r
v
i
c
e
40
A
S
o
l
a
r
B
a
c
k
f
e
e
d
B
r
e
a
k
e
r
mu
s
t
b
e
p
l
a
c
e
d
a
t
t
h
e
o
p
p
o
s
i
t
e
en
d
f
r
o
m
w
h
i
c
h
t
h
e
p
a
n
e
l
i
s
f
e
d
GROUNDING METHODPV Array Grounding MethodPV Module Manufacturer-Acceptable Grounding Method:-WEEB / WEEB LugDATA MONITORINGData Monitoring System:NONE
5
M
6
So
l
a
r
R
e
a
d
y
B
a
c
k
f
e
e
d
P
a
n
e
l
20
0
A
B
u
s
b
a
r
/
2
0
0
A
M
a
i
n
12
0
/
2
4
0
S
p
l
i
t
P
h
a
s
e
S
e
r
v
i
c
e
60
A
S
o
l
a
r
B
a
c
k
f
e
e
d
B
r
e
a
k
e
r
ta
p
p
e
d
b
u
s
b
a
r
a
h
e
a
d
o
f
m
a
i
n
,
lo
a
d
s
i
d
e
o
f
m
e
t
e
r
.
Sie
m
e
n
s
C
a
t
.
#
MC
2
0
4
0
S
1
2
0
0
J
L
C
Le
v
e
r
B
y
p
a
s
s
20
0
40
To
U
t
i
l
i
t
y
20
0
PIERCE RESIDENCE
6.24 kW Photovoltaic System
SITE ADDRESS: 2730 Bald Mountain Rd.
Vail, CO 81657
REVISION: D DATE: 6/19/13
DRAWN BY: IJE
PAGE
P-04P.O. Box 301
Carbondale, CO 81623
P 970.963.1420
F 970.963.1496
ON
E
L
I
N
E
D
I
A
G
R
A
M
All components are listed to applicable UL standards, will be
installed and labeled in accordance with the 2011 NEC, and will
pass state electrical inspection before being commissioned.
A sign will be placed on the meter that reads:
"Warning!! Photovoltaic System Connected".
NOTES:
By
Da
v
i
d
Rh
o
a
d
e
s
at
4:
4
9
pm
,
Ju
n
21
,
20
1
3
B1
3
-
0
2
3
8
Re
v
i
e
w
e
d
f
o
r
C
o
d
e
C
o
m
p
l
i
a
n
c
e
Co
d
e
:
2
0
1
2
In
t
e
r
n
a
t
i
o
n
a
l
B
u
i
l
d
i
n
g
C
o
d
e
(
I
B
C
)
By
20
1
2
ap
p
r
o
v
a
l
st
a
m
p
at
2:
3
0
pm
,
Ma
y
31
,
20
1
3
Ju
n
e
24
,
20
1
3