Loading...
HomeMy WebLinkAboutB13-0238 Plans approvedTo L o a d s CONDUCT O R S E X P O S E D T O F R E E A I R (4) 10 AW G R H W / U S E - 2 C O N D U C T O R S (1 ) 6 A W G B A R E C U G R O U N D 3/4 " E M T O R E Q U I V A L E N T (4 ) 1 0 A W G T H H N / T H W N - 2 C O N D U C T O R S (1 ) 1 0 A W G T H H N / T H W N - 2 G R O U N D 1" E M T O R E Q U I V A L E N T (3 ) 8 A W G T H H N / T H W N - 2 C O N D U C T O R S (1 ) 8 A W G T H H N / T H W N - 2 G R O U N D 1 23 4 6 2 1 3 4 6 EX I S T I N G CO N D U I T A N D CO N D U C T O R S EQ U I P M E N T S C H E D U L E PV A r r a y I n f o r m a t i o n Nu m b e r o f M o d u l e s i n S e r i e s = 1 2 Nu m b e r o f M o d u l e s i n P a r a l l e l = 2 Ra t e d M P P C u r r e n t = 1 6 . 6 A Ra t e d M P P V o l t a g e = 3 7 5 . 6 V Ma x S y s t e m V o l t a g e = 5 3 5 . 1 3 V Sh o r t C i r c u i t C u r r e n t = 1 7 . 5 2 A PV M o d u l e R a t i n g @ S T C PV M o d u l e M a n u f a c t u r e r = A L E O PV M o d u l e M o d e l = S 7 9 U 2 6 0 Ma x P o w e r C u r r e n t ( I m p ) = 8 . 3 A Ma x P o w e r V o l t a g e ( V m p ) = 3 1 . 3 V Op e n C i r c u i t V o l t a g e ( V o c ) = 3 8 . 2 V Sh o r t C i r c u i t C u r r e n t ( I s c ) = 8 . 7 6 A Ma x S e r i e s F u s e ( O C P D ) = 1 5 A Ma x P o w e r ( P m a x , S T C ) = 2 6 0 W Ma x S y s t e m V o l t a g e = 6 0 0 V Vo c T e m p . C o e f f i c i e n t = - . 3 1 % / K Pa s s t h r o u g h B o x WIL E Y - A C E 2 P In v e r t e r In v e r t e r M a n u f a c t u r e r = S M A In v e r t e r M o d e l # = S B 6 0 0 0 - U S Ma x D C V o l t a g e R a t i n g = 6 0 0 V Ma x P o w e r = 6 0 0 0 W No m i n a l A C V o l t a g e = 2 4 0 V Ma x A C C u r r e n t = 2 5 A @ 2 4 0 V A C In t e g r a t e d F u s e d D C D i s c o n n e c t AC D i s c o n n e c t NE M A 3 R Ex i s t i n g S e r v i c e 20 0 A B u s b a r / 2 0 0 A M a i n 12 0 / 2 4 0 S p l i t P h a s e S e r v i c e 40 A S o l a r B a c k f e e d B r e a k e r mu s t b e p l a c e d a t t h e o p p o s i t e en d f r o m w h i c h t h e p a n e l i s f e d GROUNDING METHODPV Array Grounding MethodPV Module Manufacturer-Acceptable Grounding Method:-WEEB / WEEB LugDATA MONITORINGData Monitoring System:NONE 5 M 6 So l a r R e a d y B a c k f e e d P a n e l 20 0 A B u s b a r / 2 0 0 A M a i n 12 0 / 2 4 0 S p l i t P h a s e S e r v i c e 60 A S o l a r B a c k f e e d B r e a k e r ta p p e d b u s b a r a h e a d o f m a i n , lo a d s i d e o f m e t e r . Sie m e n s C a t . # MC 2 0 4 0 S 1 2 0 0 J L C Le v e r B y p a s s 20 0 40 To U t i l i t y 20 0 PIERCE RESIDENCE 6.24 kW Photovoltaic System SITE ADDRESS: 2730 Bald Mountain Rd. Vail, CO 81657 REVISION: D DATE: 6/19/13 DRAWN BY: IJE PAGE P-04P.O. Box 301 Carbondale, CO 81623 P 970.963.1420 F 970.963.1496 ON E L I N E D I A G R A M All components are listed to applicable UL standards, will be installed and labeled in accordance with the 2011 NEC, and will pass state electrical inspection before being commissioned. A sign will be placed on the meter that reads: "Warning!! Photovoltaic System Connected". NOTES: By Da v i d Rh o a d e s at 4: 4 9 pm , Ju n 21 , 20 1 3 B1 3 - 0 2 3 8 Re v i e w e d f o r C o d e C o m p l i a n c e Co d e : 2 0 1 2 In t e r n a t i o n a l B u i l d i n g C o d e ( I B C ) By 20 1 2 ap p r o v a l st a m p at 2: 3 0 pm , Ma y 31 , 20 1 3 Ju n e 24 , 20 1 3