HomeMy WebLinkAboutB13-024611 -12 -2013 Inspection Request Reporting Page 14
Requested Inspect Date: Wednesday November 13, 2013
Site Address: 2940 MANN§ RANCH RD VAIL
UNIT #2
A /P /D Information
Activity: B13 -0246 Type: COMBO Sub Type: ADUP Status: ISSUED
Const Type: Occupancy: Use: Insp Area:
Owner: LANGMAID, CHARLES F. & PATRICIA C.
Contractor: CASABONNE ENTERPRISES INC. Phone: 970 - 476 -5435
Description: REMOVE AND REPLACE PLUMBING FIXTURES IN THREE BATHROOMS. REMOVE 1 BATH TUB
REPLACE WITH SHOWER. REMOVE AND REPLACE BATH FANS. REMOVE AND REPLACE BAT
CABINETS IN THREE BATHROOMS. MINOR ELECTRICAL AS NEEDED.
Requested Inspection(s)
Item: 90 BLDG -Final Requested Time: 01:30 PM
Requestor: CASABONNE ENTERPRISES INC. Phone: 970 - 476 -5435
Comments: 390-BB23
Assigned To: AGON Entered By: JMONDRAGON K
Action: Time Exp:
Item: 190 ELEC -Final
Requestor: CASABONNE ENTERPRISES INC.
Comments: 390 -8683
Assigned To: JM AGON
Action: Time Exp:
Item:
290 PLMB -Final
Requestor:
CASABONNE ENTERPRISES INC.
Comments:
390 -8683
Assigned To:
JMO GON
Action:
1. Time Exp:
Item: 390 MECH -Final
Requestor: CASABONNE ENTERPRISES INC.
Comments: 390 -8683
Assigned To: JVQN9RAGON
Action: Time Exp:
Requested Time: 11:30 AM
Phone: 970 - 476 -5435
Entered By: JMONDRAGON K
Requested Time: 11:00 AM
Phone: 970 - 476 -5435
Entered By: JMONDRAGON K
Requested Time: 01:00 PM
Phone: 970 - 476 -5435
Entered By: JMONDRAGON K
Inspection History
Item: 120 ELEC Rou h
** Approved *"
08/27/13 Inspector:
sgremmer Action:
AP APPROVED
Comment:
Item: 200 MECH -Rough
** Approved "*
08/27/13 Inspector:
sgremmer Action:
AP APPROVED
Comment:
Item: 220 PLMB - Rough /D.W.V.
*" Approved **
08/26/13 Inspector:
sgremmer Action:
DN DENIED
Comment: minimum 30" interior finish of shower
08/27/13 Inspector:
sgremmer Action:
AP APPROVED
Comment:
� � () /-qp
REPT131 Run Id: 14893
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
,.
MWiY OF VAA
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B13 -0246
Job Address: 2940 MANNS RANCH RD VAIL
Location......: UNIT #2
Parcel No....: 210103401015
OWNER LANGMAID, CHARLES F. & PATRI 07/01/2013
PO BOX 159
VAIL, CO
81658
Project #: PRJ13 -0295
Applied.....: 07/01/2013
Issued...: 07/25/2013
APPLICANT CASABONNE ENTERPRISES INC. 07/01/2013 Phone: 970 - 476 -5435
PO BOX 516
VAIL
CO 81658
License: C000003633
CONTRACTOR CASABONNE ENTERPRISES INC
PO BOX 516
VAIL
CO 81658
License: 0000003633
07/01/2013 Phone: 970-476-5435
Description:
REMOVE AND REPLACE PLUMBING FIXTURES IN THREE BATHROOMS.
REMOVE 1 BATH TUB AND REPLACE WITH SHOWER. REMOVE AND
REPLACE BATH FANS. REMOVE AND REPLACE BATH CABINETS IN
THREE BATHROOMS. MINOR ELECTRICAL AS NEEDED.
Occupancy:
Type Construction:
Valuation: $3,915.00
.................................................. ...............................
FEE SUMMARY ,,,...,.,....................,.+.....,...._.....
.................._..,,._.,,,..
Building Permit ------ - - - - ->
$97.25
Bldg Plan Check ----- - - -
- -> $63.21
Use Tax Fee------------------ - - - - ->
$0.00
Electrical Permit ---- - - - - ->
$115.00
Elec Plan Check ------ - - - - -> $74.75
Restuarant Plan Review--- - - - - ->
$0.00
Mechanical Permit - - - - - ->
$20.00
Mech Plan Check ---- - - -
- -> $5.00
Additional Fees--------------- - - - - ->
$0.00
Plumbing Permit --- - - - - ->
$30.00
Plmb Plan Check ---- - - - - -> $7.50
Recreation Fee--------------- - - - - ->
$0.00
Investigation------------------ - - - - ->
$0.00
Will Call ------------------------------ >
$20.00
TOTAL PERMIT FEES--------- - - - - ->
$432.71
Payments ------------------------------- >
$432.71
BALANCE DUE -------------- --- - ---- >
$0.00
DECLARATIONS
I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM.
combination permit-012811
lUWN
* Yl i4 #f4 #H #f!4 #44#f44ff!!ii #! #RRfl RRR# R! Rl RRRRl YR# RRRRRRRYYYYY* Y* YYYY * * * * * *YRYY * # *4fY # * * # # #44#Y # # ## 444l fYR!#!! f# RRY## RRRRYYYYRY** Y#*# 4!# f4f4fl 4!! ff!! !!!! # #Y #f # #Y # # #Y # #YY #YR #RYYY #1R
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit #: B13 -0246 Address: 2940 MANNS RANCH RD VAIL
Owner: LANGMAID, CHARLES F. & PATRICIA C. Location:1
UNIT #2
R#! 1!l RR f##!!# fR!! RR## R# YYYYRYYRYYRf4 *#Y####Rf!!!4i!# # # #Y!R # # # ## RRR# RR###### RRRRRR# Y# Y# RRRYYRY #RY *RRf #1ff #f1fR # #! # #Y # #RYR ** RRR* f* R**### f#!! RR* R!#### RRRYYR # # #RR #RfR *RRYY *f*##4R * *Hf*
combination permit_012811
TOWN OF VA1L V
REQUIRED INSPECTIONS AND STATUSES
Permit #: B13 -0246 Address: 2940 MANNS RANCH RD VAIL
Owner: LANGMAID, CHARLES F. & PATRICIA C. Location:
UNIT #2
Item: 00120 ELEC -Rough
Item: 00200 MECH -Rough
Item: 00220 PLMB- Rough /D.W.V.
Item: 00230 PLMB- Rough/Water
Item. 00060 BLDG - Sheetrock Nail
Item: 00070 BLDG -Misc.
Item: 00190 ELEC -Final
Item: 00290 PLMB -Final
Item: 00390 MECH -Final
Item: 00090 BLDG -Final
combination permit-012811
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADOCopy Reprinted on 07 -25 -2013 at 10:30:58
07/25/2013
Statement
************************************************************* * * * * * * * * * * * * * * * * * * * * * *
* * * * * * * **
Statement Number:
R130001045 Amount: $294.80 07/25/201310:30 AM
Payment Method:Credit
Crd Init: DR
Notation: VISA PETER
CASABONNE
---------------------------------------------------------------
Permit No:
B13 -0246 Type: COMBINATION BLDG PERMIT
Parcel No:
2101- 034 - 0101 -5
Site Address:
2940 MANNS RANCH RD VAIL
Location:
UNIT #2
Total Fees:
$432.71
This Payment:
$294.80 Total ALL Pmts:
$432.71
Balance:
$0.00
*************************************************************
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
ACCOUNT ITEM LIST:
Account Code
--------- - - -
Description Current Pmts
- -- ------------------------
BP 00100003111100
- - - - -- ------
BUILDING PERMIT FEES
- - - - --
97,25
EP 00100003111100
ELECTRICAL PERMIT FEES
115.00
MP 00100003111100
MECHANICAL PERMIT FEES
20.00
PF 00100003112300
PLAN CHECK FEES
12.55
PP 00100003111100
PLUMBING PERMIT FEES
30.00
WC 00100003112800
WILT, CALT, TNSPF.( TT()U VrV
nn —
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADO Statement
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Statement Number: R130000905 Amount: $137.91 07/01/201311:25 AM
Payment Method:Credit Crd Init: DR
Notation: VISA PETER
CASABONNE
-----------------------------------------------------------------------------
Permit No: B13 -0246 Type: COMBINATION BLDG PERMIT
Parcel No: 2101 - 034- 0101 -5
Site Address: 2940 MANNS RANCH RD VAIL
Location: UNIT #2
Total Fees: $432.71
This Payment: $137.91 Total ALL Pmts: $137.91
Balance: $294.80
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
PF 00100003112300 PLAN CHECK FEES 137.91
----------------------------------------------------------------------- - - - - --
TOWN OF VA(L r
Department of Community Development
75 South Frontage Road
Vail, CO 81657
Tel: 970 -479 -2128
www.vaiigov.com
Development Review Coordinator
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
Project Street Address:
za 12- M RN N6 2ehl(, 0
(Number) (Street) (Suite #)
Building /Complex Name:
Contractor Information
Business Name:
Business Address: 'FO � � ((Q
City V ft { L— State: CO Zip: e 5a
Contact Name: (,�,Y��
Contact Phone: ��� 5-1 O `�-���
Contact E -Mail:
I hereby acknowledge that I have read this application, filled out
in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to
comply with the information and plot plan, to comply with all Town
ordinances and state laws, and to build this structure according to
the town's zoning and subdivision codes, design review ap-
proved, International Building and Residential Codes and other
ordinan of the Town applicable thereto.
A
Owner /Owners Representative Signature (Required)
Applicant Information
Applicant Name: C- D /�JO�IN� U4 1 � -\�-i� J
Applicant Phone: `"l76( �3� ^U,�U J
Applicant E -Mail: QAi7�T_a y qu,, &115
Project Information�
Owner Name: 1 6�i �( —s
Parcel #: 21 o f 034 01 o f s'
(For Parcel #, contact Eagle County Assessors Office at (970 - 328 -8640 or visit
www.eaglecounty.us/patie)
For Office Use Only: Q
Fee Paid: (3-7, 1
Received From:
Cash Check #
CC: Visa / MC Last 4 CC # exp date:
Auth #
Project #: T NJ I Z
DRB #: NA-
Building Permit #: — { — o , y c
Lot #: 9 Block #__ Subdivision: V,41L�U.&Q6 c
L 13
P ��
Work Class: New( ) Addition( ) Alteration ( Y)
Type of Building:
Single - Family ( ) Duplex( / Multi - Family ( }
Commercial( ) Other(
Work Type: Interior (V) Exterior ( ) Both ( )
Valuation of
Work Included Plans Included Work
tlectncal (v)Yes ( ENO ( )Yes
( /rvo ! " i
Mechanical ( V)Yes ( )No ( )Yes
( )No 6150
Plumbing ( P)Yes ( )No ( )Yes
( )No f SCO j
Building (V�Yes ( )No It/)Yes
( )No 100-0.-
Value of all work being performed:
$ . 0v
(value based on IBC Section 109.3 & IRC Section 108.3)
Q / SF
Electrical Square Footage
.4v Jnn
Detailed Scope and Location of Work:y
Lum r 1S
N 3) or-r - - Kcmovf�_:
r. � -tome ►' � PePLrauE w )Tlt
5*WIAMOPIA Iy 7--crVAClue-
trA ► 14 M EA" P IM S )
(use additional sheet if necessary)
Date Receive . 5 V
JUL 0 1 2013
TOWN OF VAIL
00
InsulVail, Lw l -
Post Office 13ox ''888
Vail, Colorado 8168
970-5-14-3000
Fax 9 0 -s24 -3001
Mr. Ted Simonette
Nett Designs Construction
PO Box 2177
Vail, CO 81658
VIA EMAIL: nettd4ivomeast.net
December, 2013
BUILDER STATEMENTS
PROJECT: 2785 Bald Mountain Rd.
Vail, CO 816.57
SPECIFICATIONS:
R -51 7.5" polyurethane spray foam to 2xI2 exterior ceiling and 3" polyurethane spray foam to
roof rims
R -21 unfaced fiberglass batts to 2x6 exterior walls
6 mil poly to exterior walls
Membrain smart vapor barrier to exterior ceiling
R -30 unfaced fiberglass batts to 14" TA crawl ceiling
R -21 unfaced fiberglass batts to rim joists
INSULATION CARD - DO NOT REMOVE
"Per the IRC foam plastic insulation greater than 4 inches thickness shall have a maximum flame spread index of 25 and a
smoke - developed index of 450 where tested at a minimum thickness of 4 inches, provided the end use is approved in accordance
with Section 2603.9_�pecial Approval using the thickness and density intended for use.
Test Agency: Intertek ETL SEMKO
Test Report #: 3116019 -001 (a, b, c)
3116019-002 (a. b, c)
Testing and Compliance Criteria:
Applicable requirements of NFPA 286 and IBC Section 803.2
Evaluation Property:
Heat Release and Flame Spread
Issue Date: May 2, 2007
Product Tested: SPRAYTITE� and COMFORT FOAMP,
Constructions: Exterior Wails Ceiling Assembly
(covered in Y:" gypsum to interior) 8" Spray Foam 12" Spray Foam
Test Report Conclusion:
The sample submitted. installed and tested as described in this report displayed low levels of heat release and low upper level
temperatures The heat flux on the floor did not reach flashover levels. The sample did not spread flames to the ceiling during
the 40 kW exposure The flames did not spread to the extremities of the 12 -foot walls. or the rear 8 -foot wall during the test The
sample did not exhibit flashover conditions during the test. NFPA 286 does not publish passifail criteria. One must consult the
codes to determine pass /fail. This specimen did meet the criteria set forth in the 2003/2006 IBC Section 803.2.
Caution— No Hot Work - Polyurethane foam is combustible and should be treated as such.
No welding or cutting unless foam has been protected from accidental ignition by open flame.
What You Should Know About R- values
These chart shows the R -value of this insuiation. R means resistance to heat How. The higher the R- value. the greater the insuiating power "ornpare nsu,at•.cr R
va ues before you buy There are other factors to consider. The amount of insulation you need depends marniy on the climate you i ve in Also, your fuel savings from
nsulatrcn will depend upon the climate, the type and size of your house, the amount of insula' ion already in your house, and your fuel use patterns and family size f
Y, b"i toc much nsulabon. I wilt cost you more than what you 1, save on fuel To get the marked R- value, it is essential that this'nsulaficn be instahed properly
BASF Polyurethane Foam Enterprises LLC Helping Make
13630 Watertower Circle
Minneapolis. MN 55441 Buildings Better
Telephone: (763) 559 -3266
Fax (763) 559 -0945
wwv,.basf -pfe corn
ISO 9001:2000 Accredited Facilities -- Minneapolis. MN and Houston, h\
INSULATION CARD - DO NOT REMOVE
„3, 2,�
1 % F
The Chemical Company
INSULATION CARD - DO NOT REMOVE
ICC -ESR - 2642
This form must be filled out and posted to comply with building code and FTC requirements. Meets IRC Section N1101.4
requirements. Please post near electrical panel.
PLEASE ATTACH PRODUCT TECHNICAL DATA SHEET BEFORE POSTING
The follow,ng spray polyurethane foam insulation system(s) has been installed Consult International Building Code, Section 2603 Foam
Plastic Insulation. International Residential Code (IRC) R314 Foam Plastics, or International Energy Conservation Code (IECC) Section 102
for specific requirements
This spray polyurethane foam insulation system has been installed in accordance with manufacturers processing
ouidelinea to nrnvirie a thermal rp-.ictnnr A of
Area Insulated
R -Value
Thickness'
Attic Area X I L" Cc Z C
R-
51
@
. 5 inches
Sloped Ceilings
R-
@
inches
Walls (,Where. )
R-
@
inches
Wails ("'here: )
R-
@
inches
Floors (over an unheated crawl space)
R-
@
inches
Crawl Space Perimeter
R-
@
inches
Basement Exterior Walls
R-
@
inches
Other (Where 1"� t ►.M 5 )
R-
Z • 9
@
3 inches
'Nominal thicknesses are representative of a field, spray - applied foam material.
BASF Polyurethane Foam Enterprises Product(s) Installed:
(Please Print Clearly)
O COMFORT FOAMY
Walls: SPRAYTITE Permeance. perms at thickness Density Nominal 2#
F
Flame Spread Rating (ASTM E -84): ® Class 1 (25 or less) ❑ Class 2 (75 or less) tested at 4 ' thickness-
F1 COMFORT FOAM
Other: f1L J SPRAYTITE Permeance: perms at thickness Density Nominal 2#
R
Flame Spread Rating (ASTM E -84): Q Class 1 (25 or less) ❑ Class 2 (75 or less) tested at 4 ` thickness"
1 COMFORT FOAM,&
Basement Exterior: Permeance: perms at " thickness Densitv Nominal 2#
SPRAYTITEff,
Flame Spr acl Rating (ASTM E -84): Not Applicable
-------------------------------------------------------------------------
(Please Print Clearly)
Jobsite Location a 8 %��u6 AWOAJ /�-'N 2-i� Date Installed: I t{ - 3D- l 3
Building Contractor: ht C%'% 0&516l,15
Insulation Contractor: d AISJL-11/4 !L- L G
Installed By:
V /� / C_
Phone:
G-L-C
Caution— No Hot Work - Polyurethane foam is combustible and should be treated as such. No welding
or cutting un less foam has been protected from accidental ignition by open flame.
INSULATION CARD - DO NOT REMOVE