HomeMy WebLinkAboutDRB1302570, ' J -EV F Design Review Roarld A C'171� 0 14 F1110 S 11 IIIC p II l , , n olif Communit IIDevelopment", 75 Soui h II r n a . d, Vail,, Colorado, 81,161,157" e : 970.479.2.139 fay: 970.479.24-52 Project Name: WMC RADIOLOGY ROOFTOP CONDNSR DRB Number: DRB130257 Project Description: INSTALL MITSUBISHI 24,000 BTU DUCTLESS SPLIT SYSTEM IN RADIOLOGY DEPARTMENT. DRB APP FOR ROOF MOUNTED CONDENSING UNIT Participants: OWNER VAIL CLINIC INC 07/02/2013 PO BOX 40000 VAIL, CO 81658 APPLICANT AMERICAN MECHANICAL SERVICES 07/02/2013 Phone: 303-806-7300 6810 S. TUCSON WAY CENTENNIAL CO 80112 License: C000003468 CONTRACTOR AMERICAN MECHANICAL SERVICES 07/02/2013 Phone: 303-806-7300 6810 S. TUCSON WAY CENTENNIAL CO 80112 License: C000003468 Project Address: 181 W MEADOW DR VAIL WMC RADIOLOGY DEPARTMENT Location: Legal Description: Lot: E&F Block: Subdivision: VAIL VILLAGE FILING 2 Parcel Number: 2101-071-0101-3 Comments: BOARD/STAFF ACTION Motion By: Action: STAFFAPP Second By: Vote: Date of Approval: 07/10/2013 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS. Cond : 202 (PLAN): Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Planner: Jonathan Spence DRB Fee Paid: $250.00 ******************************************************************************************** TOWN OF VAIL, COLORADOCopy Reprinted on 07-02-2013 at 11:25:26 07/02/2013 Statement ******************************************************************************************** Statement Number: R130000914 Amount: $250.00 07/02/201311:25 AM Payment Method:Credit Crd Init: DR Notation: VISA RYAN MAGILL ----------------------------------------------------------------------------- Permit No: DRB130257 Type: DRB -Minor A1t,Comm/Multi Parcel No: 2101-071-0101-3 Site Address: 181 W MEADOW DR VAIL Location: VVMC RADIOLOGY DEPARTMENT Total Fees: $250.00 This Payment: $250.00 Total ALL Pmts: $250.00 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------------------------------------------------- DR 00100003112200 DESIGN REVIEW FEES 250.00 ----------------------------------------------------------------------------- TOWN OF VAIL f ]UL 2013 TOWN OF VAIL Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970-479-2128 www.vailgov.com Development Review Coordinator Application for Design Review Minor Exterior Alteration General Information: This application is required for all proposals involving minor changes to buildings and site improvements, such as roofing, painting, window additions, landscaping, fences, retaining walls, etc. Applicable Vail Town Code sections can be found at www.vailgov.com under Vail Information - Town Code Online. All projects requiring design review must receive approval prior to submitting a building permit application. An application for Design Review cannot be accepted until all required information is received by the Community Development Department, as outlined in the submittal requirements. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission. Design review approval expires one year from the date of approval, unless a building permit is issued and construction commences. Fee: $250 for Multi-Family/Commercial $20 for Single Family/Duplex Single Family -[:-Duplex F—Multi-Family FX_ Commercial Description of the Request: Physical Address: W"I W . , Wcco& u-) IJ. - Parcel Number: 2,161 0'i 10 10 13 (Contact Eagle Co. Assessor at 970-328-8640 for parcel no.) Property Owner: 11a -I U4llcf Mel, ca t (A, Ve- y - Mailing Address: Owner's Signature: /'-o_� .01 0 0©%.� 5 S - e: 970 `124 2 Primary Contact/ Owner Re'P4'e'7 sentati�' .4« /K 1 4 q .' 1 1 Mailing Address: PO _21M( y 'ao0 J). . 1 G n Phone?70 V? % 7/9 q E -Mail: m ao d � F'yy^c . co- -Fax: 7 : 70 Y7 i. 50Yq For Office Use Only: Cash_ CC:<Zg>MC Last 4 CC # )y u, Exp. Date: Auth # Check # Fee Paid: 00 Received From: -K lA,a MAG ILL Meeting Date: QS -o1'7 -1Z DRB No.: Planner: Project No: f R;S13- 0 J % Q Zoning: Land Use: Location of the Proposal: Lot: Block: Subdivision: AIL. Ui LI�Pt(.. _ C� G �, MITSUBISHI ELECTRIC COOLING & HEATING P -SERIES SUBMITTAL DATA: .. ; PUY-A24NHA4 (-BS) 24.000 : •UNTED AIR-CONDITIONING Job Name: Location: Date: Purchaser: Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction System Designation: Schedule No.: 1. u„u1� 1 qil Indoor Unit. PKA-A24KA4 1 a"tlw Outdoor Unit: PUY-A24NHA4 (-BS) GENERAL FEATURES • Wall -mounted indoor unit for residential and commercial applications • Shiny-white–exterior plastic; compact design • Quiet operation—both indoor and outdoor units • Self -check function—integrated diagnostics • Limited warranty: five years parts and seven years compressors UNIT OPTION Standard Model ................................................PUY-A24NHA4 Sea Coast (BS) Model..............................PUY-A24NHA4-BS OPTIONAL ACCESSORIES Indoor Unit Mini Condensate Pump (S13100-230, 230V) ❑ L -Connector Pipe (PAC-SC84PI, for left side unit piping installation) Outdoor Unit ❑ Drain Pan (PAC-SG63DP) ❑ Drain Socket (PAC-SG61 DS) ❑ Three -pole Disconnect Switch (TAZ-MS303) ❑ Wind Baffle (WB-PA2) ❑ Air Outlet Guide (PAC-SG59SG) ❑ Mounting Base (DSD -400N) ❑ Mounting Pad (ULTRILITE2) ❑ Wall -mounting Brackets (CWMB1) Controller Options ❑ Wireless Wall -mounted Remote Controller Kit (MHK1)* ❑ Portable Controller (MCCH1)* ❑ Outdoor AirSensor(MOS1)* 'See Submittal for information on each option. ❑ Wall -mounted Wired Remote Controller (PAR -21 MAAU) ❑ M -NET Adapter (PAC-SF81MA) ❑ CN51 Connector for Multiple Remote Controller Adapters/Duct Fan Controller (PAC-725AD) ❑ CN32 Connector for Remote On/Off (PAC-715AD) ❑ Remote Temperature Sensor (PAC-SE41TS) ❑ Remote Operation Adapter - Display and On/Off (PAC-SF40RM) ❑ Hand-held Wreless Remote Controller (PAR-FL32MA, req. PAR-FA32MA-E) ❑ Wireless Signal Receiver Module (PAR-FA32MA-E) ❑ Lockdown Bracket for Hand-held Controller (RCMKP1 CB) r IER R Control/Service Tool (PAC-SK52ST) SEACOAST PROTECTION • External Outer Panel: Phosphate coating +Acrylic -Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly ; Valve Bed: Epoxy resin coating (at edge face) • Screws (used outer side): Zinc nickel coating 5Nm + Polyvinylidene chloride coating Blue Fin" treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.. Specifications are subject to change without notice ©2013 Mitsubishi Electric US, Inc Cooling* Rated Capacity...............................24,000 Btu/h Minimum Capacity ............................12,000 Btu/h SEER ......................................17.0 Btu/h/W EER ...................................... 10.6 Btu/h/W Total Input......................................2.270 W * Rating Conditions perAHRI Standard Cooling Indoor: 80° F (27° C) DB / 67° F (19° C) WB Cooling Outdoor 95° F (35° C) DB / 75° F (24° C) WB Electrical Requirements Power Supply .................... 208 / 230V, 1 -Phase, 60 Hz Recommended Fuse/Breaker Size.......................25 A Voltage Indoor - Outdoor S1-S2 ...................... AC 208 / 230V Indoor - Outdoor S2 -S3 ...........................DC ±24V OPERATING CONDITIONS ** With optional wind baffle accessory installed. If not installed, the minimum temperature will be 23° F (-5° C) DB. Notes: Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc Indoor Unit Indoor Intake Air Outdoor Intake Air 1A Temp. Temp. Blower Motor Output.................................56 Maximum 95 F (35o C) DB 115° F (46° C) DB Cooling 570 - 635 - 700 Wet CFM 71'F 22 C WB Polypropylene Honeycomb Minimum 67° F (19° C) DB 0° F** (-18° C) DB 0.77 Moisture Removal ................................ 5.0 pt./h 57° F 14° C WB ** With optional wind baffle accessory installed. If not installed, the minimum temperature will be 23° F (-5° C) DB. Notes: Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc Indoor Unit UNIT INCHES / MM MCA.............................................. 1A Blower Motor (ECM) ........................... 0.36 F.L.A. Blower Motor Output.................................56 W Airflow (Lo - Mid - Hi) ................ 635 - 705 - 775 Dry CFM Sound Pressure Level 570 - 635 - 700 Wet CFM Air Filter ........................ Polypropylene Honeycomb Sound Pressure Level (Lo - Mid - H) ....................39 - 42 - 45 dB(A) SHF............................................. 0.77 Moisture Removal ................................ 5.0 pt./h DIMENSIONS UNIT INCHES / MM W 46-1/16 / 1,170 D 11-5/8/295 H 14-3/8/365 Weight.....................................46 lbs. / 21 kg External Finish .................... Munsell No. 1.OY 9.2 / 0.2 Field Drainpipe Size O.D........................5/8" / 16 mm Outdoor Unit INCHES / MM Compressor .................. DC Inverter -driven Twin Rotary MCA.............................................18A 13+1-3/16/330+30 MOCP............................................ 30A Fan Motor (ECM) .............................. 0.75 F.L.A. Sound Pressure Level 3/8" / 9.52 mm Cooling......................................48 dB(A) DIMENSIONS INCHES / MM W 37-3/8/950 D 13+1-3/16/330+30 H 37-1/8/943 Weight ...................................163 lbs. / 74 kg External Finish ......................Munsell No. 3Y 7.8 / 1.1 Refrigerant Type .................................. R41 OA Refrigerant Pipe Size O.D. Gas Side ............................... 5/8" / 15.88 mm Liquid Side ............................... 3/8" / 9.52 mm Max. Refrigerant Pipe Length ..................... 165'/ 50 m Max. Refrigerant Pipe Height Difference ............ 100'/ 30 m Connection Method ................................Flared KnockoLA hole far leftpi piny Top side Unit: inch (mm) 16-11!16 (4237) 17 (431 7). tD (V N � � m .fi Left side ^ v Front Lida Right side 2-29!52 Sleeve Th (Field su ied 02-15116 (S475) 0_ t? s a (tions are subject to change without notice. i c 33-21!32 (£55) 9-12 (241) \ 115/9 (195) 3A6 (5) 46-1A6 (1170) Knadrout rule for rl t pin Front side (Grille Open) 0 eration lam R AND BY IaIry ALTenn incl block for power S Terminal block for Filterhook _ MA-femote controller(on! Emergency operation Switch 23-1 Under side 02013 Mitsubishi Electric US, Inc MITSUBISHI /` ELECTRIC if COOLING & HEATING Live Better 91twy Smal AG __J VRJ�L�Lndafd 2101240 T US 3400 Lawrenceville Suwanee Rd L's�0 Suwanee, GA 30024 Intertek Tele 67&376-2900•Fax: 800-889-9904 Toll Free 800-433-4822 www.mehvac.com FORM# PKA-A24KA4 - PUY-A24NHA4 (-BS) - 201302 Specifications are subject to change without notice. 02013 Mitsubishi Electric US, Inc o Unit: mm (inch) crrE>6L F <94/6-rt>OLE <ZfM1`L>BZ 2 % ao <91t9U OL9 $ 35 E'° _ <ZEl1- > 95 $ Qfh`Za ES m m a g - <ZFJ6L-L L>L99 L. 28 S a <ZE/5Z-L> SV O <9LIL-LL>E" L. IPA r >8 a` N a� <EI>OEE " /< GRIE-L,OC s <ZEI6UEZ <fl�491> ELr <9f99> 6L2 <91IC C>I6 m //ILJI\� <e/l-LD Erb R � a " z y a m <ZEILi>Lf U 8s or! o�000 0000°o g=t g =off `gvv aha r Z QoR " Y Z m E 2 co 0. o �� a m -C <94IC'L-Ao LL v ZL2>E9 ww001 viry w 005 airy y�y UJ U „ a y „ v' „LU a y�c F N N p? N s cvlll-1>L <ZC6Z>CZ ` � _ <9IL'Z>EL QC16Z>C2 .E 4 77 E N Q �° v E II{�� I V C Z p J Y C Cp y - IVB n E ��� d g �A xx Ej Ch: SSE tS - m MITSUBISHI /` ELECTRIC if COOLING & HEATING Live Better 91twy Smal AG __J VRJ�L�Lndafd 2101240 T US 3400 Lawrenceville Suwanee Rd L's�0 Suwanee, GA 30024 Intertek Tele 67&376-2900•Fax: 800-889-9904 Toll Free 800-433-4822 www.mehvac.com FORM# PKA-A24KA4 - PUY-A24NHA4 (-BS) - 201302 Specifications are subject to change without notice. 02013 Mitsubishi Electric US, Inc