Loading...
HomeMy WebLinkAboutF13-0024 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES TOWWOF 07M Town of Vail, Fire and Emergency Services Department, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2157, inspections 970.479.2252 SPRINKLER PERMIT Permit #: F13-0024 Project #: PRJ12-0176 Job Address: 660 LIONSHEAD PL VAIL Status . . . : ISSUED Location.....: LION SQUARE LODGE UNIT 753 Issued.....: 07130/2013 Parcel No...: 210107202008 OWNER LEST INC 07/02/2013 C/O ABBY MOBINE 5817 BUCKNELL AVE LA JOLLA CA 92037 APPLICANT ALLIANCE MECHANICAL INC 07/02/2013 Phone: 970-328-0303 RON AHO PO BOX 1855 EAGLE CO 81632 License: C000003169 CONTRACTOR ALLIANCE MECHANICAL INC 07/02/2013 Phone: 970-328-0303 RON AHO PO BOX 1855 EAGLE CO 81632 License: C000003169 Desciption: ADDITION - NORTHEAST BEDROOM AND DINING Valuation: $5,000.00 xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx FEE SUMMARY xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxrxy Sprinkler Fee........................ $212.50 Plan Review Fee.................. $432.00 InvestigationFee................... $0.00 Payments............................. $644.50 TOTAL FEES....................... $644.50 BALANCE DUE............. $0.00 *xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx*xxxxxxxxxxx**xxx*xx**xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 53 (FIRE 2007) Monitored fire sprinkler system required and shall comply with NFPA 13 (2007) and VFES Standards. x**x*xx**xxxxxxxxx*xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx***xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxi DECLARATIONS I agree to comply with the information and fire alarm system drawings, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approval, International Fire Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO (72) HOURS IN ADVANCE BY TELEPHONE AT 970-479-2252 FROM 8:00 AM - 5 PM. 4` Department,of Community Development 75 South Frontage Road Vail,;Colorado: 1 Te7 970 79 EsC- <; Web: WWWr. a ' Devel ne.n •j] EIRE SPRINKLER PERMIT Commercial &Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado Plan Registration form 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: Office Use: n f Project#: - (Number) (Street) (Suite#) I 7 0070 �) Building Permit#:� Building/Complex Name: (//elf r.�'�h F-171) S p rinkler Permit#: Contractor In rmatio : Lot#: Block# Subdivision: Company: �/'J?2 Com+Aress: Detailed Description of Work:City: State: Zip: p e� —Conts? i (use additional sheet if n essary) Contact Phone: cz 3° E-Mail6&0Z- <42; " I C V de-47, Detailed Location of Work: Town of Vail Contractor Registration No.: Does a Fire Alarm Exist? Yes No( ) Contr for Signature (required) °Does a Sprinkler System Exist? Yes ()n No( ) Property Information ^Work Class: Parcel#: �(�1Q�2 � $New( ) Addition ( ) Remodel) Repair( ) (For parcel#,contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Retro-Fit( ) Other( ) Tenant Name: �\ Type of Building: Owner Name: \\2�\SY� � �'�CLIC Single-Family( ) Duplex( ) Multi-Family(4 .'Commercial ( ) Restaurant( ) Other( ) Complete Valuation for Fire Sprinkler Permit: �— Date Received: Fire Sprinkler$ h� ;,a�•� c- JUL 0 2 2013 TOWN OF VAIL 29-May-09 ALLIANCE MECHANICAL INC. P O BOX 1855 Eagle, Colorado. 81631 PH# 970.328.0303, FAX# 970.328.0378 Vail Fire Department 7/2/2013 42 West Meadow Dr Vail, Co 81657 Phone: (970)479-2252 Project: Lions Head lodge unit #753 Attention: Mike Vaughn This letter concerns this gut and remodel of this unit. Moving of existing sprinkler heads to give proper coverage in this tenant finish remodel. Four additional heads will be added. Existing piping will be removed and capped per your permission during demo of this unit to prevent damage to the live system. Hose riser was moved slightly and reinstalled per your permission. Alliance Mechanical Inc. will follow N.F.P.A. code while working on this remodel using like materials and pipe sizes identical to existing materials already installed in said project. Copper pipe will be type "M" copper with wrought copper fittings. Engineered prints enclosed. I will be performing the work on a T&M basis and expect it to cost $5,000.00 Sincerely, Ron Aho President Alliance Mechanical Bulletin 006 Rev. H Model RFC30 (SIN RA0611) O Model RFC43 (SIN RA0612) Model RFC49 (SIN RA0616) g Residential Flat Concealed x Sprinklers ` A Residential Flat Concealed ` Sprinkler engineered for a minimum design density of 0.05 gpm/ft2 with low GPM requirements. �10� Features 1. Very low water flow requirements. 2. Cover plate attachment (Plain or Perforated) with 112" (13mm)Total adjustment. ; 3. Thread-On/Thread-Off or Push-On/Thread Off cover attachment option. 4. Smooth aesthetic ceiling profile. 5. Available in brass, chrome and black plated or painted finishes. Listings & Approval 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) 2. NYC MEA 258-93-E UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC30, RFC43 and RFC49 Concealed Residen- tial Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC30, RFC43 and RFC49 sprinklers discharge water in a hemispherical pattern below the sprinkler de- and positively attached and blends into the ceiling, con- flector. Residential distribution patterns are higher and cealmg the most dependable fire protection available,an automatic generally contain a finer droplet size than standard sprin- atic sprinkler system. kler patterns. The RFC30, RFC43 and RFC49 are UL Listed Residen- The combination of speed of operation and high dis- tial Sprinklers to be installed in the residential portions charge pattern required for residential sprinklers has of any occupancy in accordance with NFPA 13, 13R, & demonstrated, in fire testing, an ability for controlling 13D. residential fires, and thereby providing significant evacu- The RFC30, RFC43 and RFC49 can reduce the need resid time for occupants. for precise cutting of drop nipples. The threaded cover ation RFC43 and RFC49 Sprinklers provide the plate assembly can be adjusted without tools to fit ac- The time for best form of fire protection by combining an attractive ap- curately against the ceiling. The fire protection system pearance and 1/2" (13mm) of cover adjustment for ease need not be shut down to adjust or remove the cover of installation. The small diameter cover plate is easily Plate assembly. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application and Installation The RFC30, RFC43 and RFC49, for residential instal- When inserting or removing the wrench from the sprin- lations, use a 165°F (74°C) fusible solder link in a tun- kler/cup assembly, care should be taken to prevent dam- ing fork style sprinkler frame with a drop-down deflector. age to the sprinkler. DO NOT WRENCH ON ANY OTHER This assembly is recessed into the ceiling and concealed PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL by a flat cover plate. The cover plate is attached to the RFC30, RFC43 AND RFC49 CONCEALED SPRINKLERS skirt, using 135°F(57°C)ordinary temperature classifica- MUST BE INSTALLED ONLY WITH 135°F RATED COV- tion solder.When the ceiling temperature rises,the solder ERS. holding the cover plate releases the cover allowing the Note:A leak tight 1/2" NPT(R1/2)sprinkler joint can be ob- deflector to drop into position and exposing the sprinkler tained with a torque of 8-18 ft-lbs(10,8-24,4 N-m). Do not inside to ceiling temperature. The subsequent operation tighten sprinklers over maximum recommended torque. It of the solder link opens the waterway and causes the de- may cause leakage or impairment of the sprinklers. flector to drop into position to distribute the discharging Cover assemblies provide up to 1/2" (13mm) of adjust- water in a hemispherical pattern below the sprinkler de- ment. Turn the cover clockwise until the flange is in con- flector. Any adjustment of thread engagement between tact with the ceiling. For the push-on/thread-off option, the cover plate and cup will assure that the drop-down the cover assembly is pushed onto the cup and final ad- deflector is properly located below the ceiling. The resi- justment is made by turning the cover clockwise until the dential distribution pattern contains a finer droplet size skirt flange makes full contact with the ceiling. Cover re- than a standard sprinkler, and the pattern produces sig- moval requires turning in the counter-clockwise direction. nificantly higher wall wetting. In ceilings that have a plenum space above the sprin- After a 25/8 inch diameter hole is cut in the ceiling, the kler, the plenum space may have neutral or negative sprinkler is to be installed with the Model FC Wrench. pressurization but must not be positively pressurized. When installing a sprinkler, the wrench is first positioned Inspect all sprinklers after installation to ensure that the into the sprinkler/cup assembly and around the hexago- gap between the cover plate and ceiling and the 4 slots nal body of the sprinkler frame. The Wrench must bottom in the cup are all open and free from any air flow impedi- out against the cup in order to ensure proper, safe instal- ment. lation. The sprinkler is then tightened into the pipe fitting. Thread Nominal Sprinkler Temp.Assembly Max. Max. Model Temp Rat- Ambient K (SIN) Size Orifice ing p.Rating Temp. Factor Pressure Inch(mm) Inch(mm) of °C OF °C OF oC psi(bar) RFC 30 112"(15) 21/,(8,2) 165 74 135 57 100 38 3.0 175(12) (RA0611) RFC (RA061 2) 1/2„(15) 3/e(10) 165 74 135 57 100 38 4.3 175(12) RFC 49 YZ"(15) '/1s(11) 165 74 135 57 100 38 4.9 175(12) (RA0616) Note: 1 bar= 100 Kpa RFC 30 Ordinary Temp.Rating Max.Coverage Max.Spacing (165°F/74°C) Minimum area P 9 Spacing Ft x Ft(m x m) Ft(m) Flow Pressure Ft(m) GPM(Vmin) PSI(bar) 12 x 12(3,6 x 3,6) 12(3,6) 9(34,1) 9.0(0,62) 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 10(37,B) 11.0(0,76) For Ceiling types refer to NFPA 13, 13R or 13D 2. RFC 43 Ordinary Temp.Rating Max.Coverage Max.Spacing (155°F/68°C) Minimum area P g Spacing Ft x Ft(m x m) Ft(m) Flow Pressure Ft(m) GPM(Umin) PSI(bar) 12 x 12(3,6 x 3,6) 12(3,6) 12(4,5) 7.8(0,54) 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 9.1 (0,63) 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 9.1 (0,63) 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 18(68) 17.5(1,21) 20 x 20(6,1 x 6,1) 20(6,1) 21 (79) 23.8(1,64) For Ceiling types refer to NFPA 13, 13R or 13D RFC 49 Max.Coverage Ordinary Temp.Rating Minimum Max.Spacing (155' 8-C)area Ft(m) Flow Pressure Spacing Ft x Ft(m x m) GPM Umin PSI(bar) Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0(0,48) 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48) 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 7.0(0,48) 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 17(69,3) 12.0(0,83) 20 x 20(6,1 x 6,1) 20(6,1) 20(75,73) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model RFC30, RFC43 and RFC49 Concealed Sprin- symmetric lever mechanism, maintaining a Teflon-coated klers should be inspected quarterly and the sprinkler Belleville spring washer and machined brass cap water system maintained in accordance with NFPA 25. Do not seal assembly containing no plastic parts. Sprinkler clean sprinklers with soap and water, ammonia or any K-factor shall be nominal 3.0(44), 4.3(62.4), and 4.91 other cleaning fluids. Remove dust by using a soft brush (70)having a 5/16", %" and 7/16" orifice. Temperature rating or gentle vacuuming. Remove any sprinkler cover plate shall be Ordinary 165°F(74°C); cover plate temperature assembly which has been painted(other than factory ap- rating to be 135°F(57 0C). Cover plate assembly shall plied) or damaged in any way. A stock of spare sprin- consist of a brass cover plate and copper alloy retainer klers should be maintained to allow quick replacement flange allowing a 1h" cover plate adjustment. Any secure of damaged or operated sprinklers. Prior to installation, engagement between the cover plate and the cup will sprinklers should be maintained in the original cartons assure that the drop-down deflector is properly located and packaging until used to minimize the potential for below the ceiling. A plastic protective cap shall be damage to sprinklers that would cause improper opera- provided and factory installed inside the sprinkler cup tion or non-operation. to protect the drop-down sprinkler deflector from dam- age,which could occur during construction before the Model RFC30, RFC43 and RFC49 Residential cover plate is installed. Standard cover finish: [Chrome] Concealed Sprinkler Specification [White] [Specialty-specify]. Residential concealed sprinklers shall be Reliable Model RFC30, SIN RA0611 Sprinklers shall be cULus Listed low flow residential con- (Bulletin 006), Model RFC43, SIN RA0612(Bulletin 006) cealed sprinklers with drop-down deflector and adjust- or Model RFC49, SIN RA0616(Bulletin 006). able flat cover plate engineered for a minimum design density of 0.05 gpm/ft2. Sprinkler frame and deflector shall be of bronze frame construction having a 112" NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with 3. Ordering Information Cover Plate Finishes0) Specify: Standard Finishes 1. Sprinkler Model Chrome 2. Cover Plate Finish White Paint 3. Thread-On or Special Application Push-On Feature Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White - Satin Chrome (') Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi-gloss, unless specified otherwise. �3 QO (Z)For the perforated style cover- plate,consult factory for avail- ability on these and other cus- tom finishes. 1° x 112° REDUCING TEE OR ELBOW ni ui 22°[66.55mm] 2 "[58.42mm] DIA HOLE IN CEILING CUP 2°[50.8mmJ MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING °[12.70mm] MAX. 4.96mm COVER ADJUSTMENT ( J FLAT COVER PLATE ,3�"(84.21mm] DIA. ASSEMBLY SPRINKLER 00er001B COVER PLATE: 1/2" L 12. 7mm] ADJUSTMENT The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co.,Inc. ® Recycled ® (800)431-1588 Sales Offices Paper iabilm (800)848-6051 Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.05/13 P/N 9999970261 Bulletin 006 Rev. H Model RFC30 (SIN RA0611) R Model RFC43 (SIN RA0612) . Model RFC49 (SIN RA0616) Residential Flat Concealed x CD Sprinklers ` A Residential Flat Concealed I R I able Sprinkler engineered for a minimum • design density of 0.05 gpm/ft2 with low GPM requirements. � t Features o� 1. Very low water flow requirements. 2. Cover plate attachment (Plain or Perforated) with 112" (13mm)Total adjustment. 3. Thread-0n/Thread-Off or Push-On/Thread Off cover attachment option. 4. Smooth aesthetic ceiling profile. .,' .rer•, 5. Available in brass, chrome and black plated - or painted finishes. Listings & Approval 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) 2. NYC MEA 258-93-E UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC30, RFC43 and RFC49 Concealed Residen- tial Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC30, RFC43 and RFC49 sprinklers discharge water in a hemispherical pattern below the sprinkler de- and positively attached and blends into the ceiling, con- flector. Residential distribution patterns are higher and cealing the most dependable fire protection available,an automatic sprinkler system. generally contain a finer droplet size than standard sprin- kler patterns. The RFC30, RFC43 and RFC49 are UL Listed Residen- The combination of speed of operation and high dis- tial Sprinklers to be installed in the residential portions charge pattern required for residential sprinklers has of any occupancy in accordance with NFPA 13, 13R, & demonstrated, in fire testing, an ability for controlling 13 residential fires, and thereby providing significant evacu- The RFC30, RFC43 and RFC49 can reduce the need time for occupants. for precise cutting of drop nipples. The threaded cover ation t plate assembly can be adjusted without tools to fit ac- The ime for RFC43 and RFC49 Sprinklers provide the best form of fire protection by combining an attractive ap- curately against the ceiling. The fire protection system pearance and 1/2" (13mm) of cover adjustment for ease need not be shut down to adjust or remove the cover of installation. The small diameter cover plate is easily plate assembly. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application and Installation The RFC30, RFC43 and RFC49, for residential instal- When inserting or removing the wrench from the sprin- lations, use a 165°F (74°C) fusible solder link in a tun- kler/cup assembly, care should be taken to prevent dam- ing fork style sprinkler frame with a drop-down deflector. age to the sprinkler. DO NOT WRENCH ON ANY OTHER This assembly is recessed into the ceiling and concealed PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL by a flat cover plate. The cover plate is attached to the RFC30, RFC43 AND RFC49 CONCEALED SPRINKLERS skirt, using 135°F(57°C)ordinary temperature classifica- MUST BE INSTALLED ONLY WITH 135°F RATED COV- tion solder.When the ceiling temperature rises,the solder ERS. holding the cover plate releases the cover allowing the Note:A leak tight 1/2" NPT(R1/2)sprinkler joint can be ob- deflector to drop into position and exposing the sprinkler tained with a torque of 8-18 ft-lbs(10,8-24,4 N-m). Do not inside to ceiling temperature. The subsequent operation tighten sprinklers over maximum recommended torque. It of the solder link opens the waterway and causes the de- may cause leakage or impairment of the sprinklers. flector to drop into position to distribute the discharging Cover assemblies provide up to 112" (13mm) of adjust- water in a hemispherical pattern below the sprinkler de- ment. Turn the cover clockwise until the flange is in con- flector. Any adjustment of thread engagement between tact with the ceiling. For the push-on/thread-off option, the cover plate and cup will assure that the drop-down the cover assembly is pushed onto the cup and final ad- deflector is properly located below the ceiling. The resi- justment is made by turning the cover clockwise until the dential distribution pattern contains a finer droplet size skirt flange makes full contact with the ceiling. Cover re- than a standard sprinkler, and the pattern produces sig- moval requires turning in the counter-clockwise direction. nificantly higher wall wetting. In ceilings that have a plenum space above the sprin- After a 25/8 inch diameter hole is cut in the ceiling, the kler, the plenum space may have neutral or negative sprinkler is to be installed with the Model FC Wrench. pressurization but must not be positively pressurized. When installing a sprinkler, the wrench is first positioned Inspect all sprinklers after installation to ensure that the into the sprinkler/cup assembly and around the hexago- gap between the cover plate and ceiling and the 4 slots nal body of the sprinkler frame. The Wrench must bottom in the cup are all open and free from any air flow impedi- out against the cup in order to ensure proper, safe instal- ment. lation. The sprinkler is then tightened into the pipe fitting. Sprinkler CCP Assembly ax. Model Thread Nominal T m emp Rat- y Ambient K Max. Size Orifice Temp.Rating Pressure (SIN) Inch(mm) Inch(mm) F Temp °C °F °C OFO Factor C psi(bar) RFC 30 (RA0611) /2 (15) 21/64(8,2) 165 74 135 57 100 38 3.0 175(12) RFC 43 (RA0612) Yz (15) 3/e(10) 165 74 135 57 100 38 4.3 175(12) RFC 49 1//(15) '/16(11) 165 74 135 57 100 38 4.9 175(12) (RA0616) Note: 1 bar= 100 Kpa RFC 30 Ordinary Temp.Rating Max.Coverage 165°F/74°C Minimum area Max.Spacing ( ) Spacing Ft x Ft(m x m) Ft(m) Flow Pressure Ft(m) GPM(Umin) PSI(bar) 12 x 12(3,6 x 3,6) 12(3,6) 9(34,1) 9.0(0,62) 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 10(37,8) 11.0(0,76) For Ceiling types refer to NFPA 13, 13R or 13D 2. RFC 43 Ordinary Temp. Rating Max.Coverage Max.Spacing (155°F/68°C) Minimum area Ft(m) Flow P Spacing Pressure Ft x Ft(m x m) Ft(m) GPM(Umin) PSI(bar) 12 x 12(3,6 x 3,6) 12(3,6) 12(4,5) 7.8(0,54) 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 9.1 (0,63) 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 9.1 (0,63) 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 18(68) 17.5(1,21) 20 x 20(6,1 x 6,1) 20(6,1) 21 (79) 23.8(1,64) For Ceiling types refer to NFPA 13, 13R or 13D RFC 49 Max.Coverage Ordinary Temp.Rating Minimum Max.Spacing (155- 8-C)area Ft(m) Flow Pressure Spacing Ft x Ft(m x m) GPM Umin PSI(bar) Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0(0,48) 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48) 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 7.0(0,48) 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 17(69,3) 12.0(0,83) 20 x 20(6,1 x 6,1) 20(6,1) 20(75,73) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model RFC30, RFC43 and RFC49 Concealed Sprin- symmetric lever mechanism, maintaining a Teflon-coated klers should be inspected quarterly and the sprinkler Belleville spring washer and machined brass cap water system maintained in accordance with NFPA 25. Do not seal assembly containing no plastic parts. Sprinkler clean sprinklers with soap and water, ammonia or any K-factor shall be nominal 3.0(44), 4.3(62.4), and 4.91 other cleaning fluids. Remove dust by using a soft brush (70)having a 5/,6",3/6" and 7/,6"orifice.Temperature rating or gentle vacuuming. Remove any sprinkler cover plate shall be Ordinary 165°F(74°C); cover plate temperature assembly which has been painted(other than factory ap- rating to be 135°F(57C). Cover plate assembly shall plied) or damaged in any way. A stock of spare sprin- consist of a brass cover plate and copper alloy retainer klers should be maintained to allow quick replacement flange allowing a 112" cover plate adjustment. Any secure of damaged or operated sprinklers. Prior to installation, engagement between the cover plate and the cup will sprinklers should be maintained in the original cartons assure that the drop-down deflector is properly located and packaging until used to minimize the potential for below the ceiling. A plastic protective cap shall be damage to sprinklers that would cause improper opera- provided and factory installed inside the sprinkler cup tion or non-operation. to protect the drop-down sprinkler deflector from dam- age,which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] Concealed Sprinkler Specification [White] [Specialty-specify]. Residential concealed sprinklers shall be Reliable Model RFC30, SIN RA0611 Sprinklers shall be cULus Listed low flow residential con- (Bulletin 006), Model RFC43, SIN RA0612(Bulletin 006) cealed sprinklers with drop-down deflector and adjust- or Model RFC49, SIN RA0616(Bulletin 006). able flat cover plate engineered for a minimum design density of 0.05 gpm/ft2. Sprinkler frame and deflector shall be of bronze frame construction having a Y2" NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with 3. Ordering Information Cover Plate Finishes0) Specify: Standard Finishes 1. Sprinkler Model Chrome 2. Cover Plate Finish White Paint 3. Thread-On or Special Application Push-On Feature Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome (') Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi-gloss, unless specified otherwise. CIO (2)For the perforated style cover- plate,consult factory for avail- ability on these and other cus- tom finishes. 1' x 112" REDUCING TEE OR ELBOW u� ui ni ui [66.55mm] 'J"[58.42mm] DIA HOLE IN CEILING CUP 2°[50.8mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING L/11iiiii "[12.70mml MAX. COVER ADJUSTMENT [4.96mm] FLAT COVER PLATE 3 "[84.21mm] DIA. ASSEMBLY SPRINKLER OWFGOie COVER PLATE 1,12„ L12.7mm-1 ADJUSTMENT The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting Irfe and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by Reliabili The Reliable Automatic Sprinkler Co.,Inc. Recycled (800)431-1588 Sales Offices Paper (800)848-6051 Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.05/13 PM 9999970261 Bulletin 006 Rev. H Model RFC30 (SIN RA0611) R I a ® Model RFC43 (SIN RA0612) . Model RFC49 (SIN RA0616) I bi Residential Flat Concealed Sprinklers ` A Residential Flat Concealed Sprinkler engineered for a minimum „ • design density of 0.05 gpm/ft2 with low GPM requirements. Features 1. Very low water flow requirements. 2. Cover plate attachment (Plain or Perforated) with 112" (13mm)Total adjustment. 3. Thread-0n/Thread-Off or Push-On/Thread Off cover attachment option. 4. Smooth aesthetic ceiling profile. 5. Available in brass, chrome and black plated or painted finishes. Listings & Approval 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) 2. NYC MEA 258-93-E UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC30, RFC43 and RFC49 Concealed Residen- tial Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC30, RFC43 and RFC49 sprinklers discharge and positively attached and blends into the ceiling, con- water in a hemispherical pattern below the sprinkler de- flector. Residential distribution patterns are higher and cealing the most dependable fire protection available, an automatic sprinkler system. generally contain a finer droplet size than standard sprin- g patterns. The RFC30, RFC43 and RFC49 are UL Listed Residen- The combination of speed of operation and high dis- tial Sprinklers to be installed in the residential portions charge pattern required for residential sprinklers has of any occupancy in accordance with NFPA 13, 13R, & demonstrated, in fire testing, an ability for controlling 13D. residential fires,and thereby providing significant evacu- The RFC30, RFC43 and RFC49 can reduce the need resid time for occupants. for precise cutting of drop nipples. The threaded cover ation RFC43 and RFC49 Sprinklers provide the plate assembly can be adjusted without tools to fit ac- The time for best form of fire protection by combining an attractive ap- curately against the ceiling. The fire protection system pearance and 1/2" (13mm) of cover adjustment for ease need not be shut down to adjust or remove the cover of installation. The small diameter cover plate is easily Plate assembly. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application and Installation The RFC30, RFC43 and RFC49, for residential instal- When inserting or removing the wrench from the sprin- lations, use a 165°F (74°C) fusible solder link in a tun- kler/cup assembly, care should be taken to prevent dam- ing fork style sprinkler frame with a drop-down deflector. age to the sprinkler. DO NOT WRENCH ON ANY OTHER This assembly is recessed into the ceiling and concealed PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL by a flat cover plate. The cover plate is attached to the RFC30, RFC43 AND RFC49 CONCEALED SPRINKLERS skirt, using 135°F(57°C)ordinary temperature classifica- MUST BE INSTALLED ONLY WITH 135°F RATED COV- tion solder.When the ceiling temperature rises,the solder ERS. holding the cover plate releases the cover allowing the Note:A leak tight 1/2" NPT(R1/2)sprinkler joint can be ob- deflector to drop into position and exposing the sprinkler tained with a torque of 8-18 ft-lbs(10,8-24,4 N-m). Do not inside to ceiling temperature. The subsequent operation tighten sprinklers over maximum recommended torque. It of the solder link opens the waterway and causes the de- may cause leakage or impairment of the sprinklers. flector to drop into position to distribute the discharging Cover assemblies provide up to 1/2" (13mm) of adjust- water in a hemispherical pattern below the sprinkler de- ment. Turn the cover clockwise until the flange is in con- flector. Any adjustment of thread engagement between tact with the ceiling. For the push-on/thread-off option, the cover plate and cup will assure that the drop-down the cover assembly is pushed onto the cup and final ad- deflector is properly located below the ceiling. The resi- justment is made by turning the cover clockwise until the dential distribution pattern contains a finer droplet size skirt flange makes full contact with the ceiling. Cover re- than a standard sprinkler, and the pattern produces sig- moval requires turning in the counter-clockwise direction. nificantly higher wall wetting. In ceilings that have a plenum space above the sprin- After a 25/8 inch diameter hole is cut in the ceiling, the kler, the plenum space may have neutral or negative sprinkler is to be installed with the Model FC Wrench. pressurization but must not be positively pressurized. When installing a sprinkler, the wrench is first positioned Inspect all sprinklers after installation to ensure that the into the sprinkler/cup assembly and around the hexago- gap between the cover plate and ceiling and the 4 slots nal body of the sprinkler frame. The Wrench must bottom in the cup are all open and free from any air flow impedi- out against the cup in order to ensure proper, safe instal- ment. lation. The sprinkler is then tightened into the pipe fitting. Thread Nominal Sprinkler CCP Assembly Max. Max. Model Temp Rat- Temp.Rating Ambient K (SIN) Size Orifice ing p. g Temp. Factor Pressure Inch(mm) Inch(mm) psi(bar) OF °C OF °C OF °C RFC 30 112"(15) 21/,(8,2) 165 74 135 57 100 38 3.0 175(12) (RA0611) RFC 43 112"(15) 3/e(10) 165 74 135 57 100 38 4.3 175(12) (RA0612) RFC 49 (RA0616) 1/2 (15) 7/16(11) 165 74 135 57 100 38 4.9 175(12) Note: 1 bar= 100 Kpa RFC 30 Ordinary Temp.Rating Max.Coverage Minimum area Max.Spacing (1650F/740c) Spacing Ft(m) Flow Pressure p g Ft x Ft(m x m) GPM(Vmin) PSI(bar) Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 9(34,1) 9.0(0,62) 8(2.4) 14 x 14(4,3 x 4,3) 14(4,3) 10(37,8) 11.0(0,76) For Ceiling types refer to NFPA 13, 13R or 13D 2. RFC 43 Max.Coverage Ordinary Temp.Rating Minimum area Max.Spacing (155 F/68 C) Flow Pressure Spacing Ft(m) FtxFt(mxm) Ft(m) GPM(Umin) PSI(bar) 12 x 12(3,6 x 3,6) 12(3.6) 12(4,5) 7.8(0,54) 14 x 14(4,3 x 4,3) 14(4.3) 13(49) 9.1 (0,63) 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 9.1 (0,63) 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 18(68) 17.5(1,21) 20x20(6,1x6,1) 20(6,1) 21(79) 23.8(1,64) For Ceiling types refer to NFPA 13, 13R or 13D RFC 49 Max.Coverage Ordinary Temp.Rating Minimum area Max.Spacing 155T/68°C Spacing Ft x Ft(m x m) Ft(m) Flow Pressure Ft(m) GPM(Uml n PSI bar 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0(0,48) 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48) 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 7.0(0,48) 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 17(69,3) 12.0(0,83) 20 x 20(6,1 x 6,1) 20(6,1) 20(75,73) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model RFC30, RFC43 and RFC49 Concealed Sprin- symmetric lever mechanism, maintaining a Teflon-coated klers should be inspected quarterly and the sprinkler Belleville spring washer and machined brass cap water system maintained in accordance with NFPA 25. Do not seal assembly containing no plastic parts. Sprinkler clean sprinklers with soap and water, ammonia or any K-factor shall be nominal 3.0(44), 4.3(62.4), and 4.91 other cleaning fluids. Remove dust by using a soft brush (70) having a 5/16", 3/8"and 7/16"orifice. Temperature rating or gentle vacuuming. Remove any sprinkler cover plate shall be Ordinary 165°F(74°C); cover plate temperature assembly which has been painted(other than factory ap- rating to be 135°F(57C). Cover plate assembly shall plied) or damaged in any way. A stock of spare sprin- consist of a brass cover plate and copper alloy retainer klers should be maintained to allow quick replacement flange allowing a 1/2" cover plate adjustment. Any secure of damaged or operated sprinklers. Prior to installation, engagement between the cover plate and the cup will sprinklers should be maintained in the original cartons assure that the drop-down deflector is properly located and packaging until used to minimize the potential for below the ceiling. A plastic protective cap shall be damage to sprinklers that would cause improper opera- provided and factory installed inside the sprinkler cup tion or non-operation. to protect the drop-down sprinkler deflector from dam- age,which could occur during construction before the Model RFC30, RFC43 and RFC49 Residential cover plate is installed. Standard cover finish: [Chrome] Concealed Sprinkler Specification [White] [Specialty-specify]. Residential concealed sprinklers shall be Reliable Model RFC30, SIN RA0611 Sprinklers shall be cULus Listed low flow residential con- (Bulletin 006), Model RFC43, SIN RA0612(Bulletin 006) cealed sprinklers with drop-down deflector and adjust- or Model RFC49, SIN RA0616(Bulletin 006). able flat cover plate engineered for a minimum design density of 0.05 gpm/ft2. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with 3. Ordering Information Cover Plate Finishes0) Specify: Standard Finishes 1. Sprinkler Model Chrome 2. Cover Plate Finish White Paint --- 3. Thread-On or Special Application Push-On Feature Finishes(z) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi-gloss, unless specified otherwise. =]Q O (2)For the perforated style cover- plate,consult factory for avail- ability on these and other cus- tom finishes. 1""x 112" REDUCING TEE OR ELBOW n all 2 "[66.55mm] [58.42mm] DlA HOLE IN CEILING CUP 1,77] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING "[12.70mm] MAX. COVER ADJUSTMENT "[4.96mm] FLAT COVER PLATE 3j"[84.21mm] DIA. ASSEMBLY SPRINKLER OosrGOre COVER PLATE 112" [12.7mm-Z ADJUSTMENT The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting fife and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co.,Inc. ® Recycled 0 (800)431-1588 Sales Offices Paper iabili (800)848-6051 Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices { www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.05/13 PIN 9999970261 f Bulletin 006 Rev. H Model RFC30 (SIN RA0611) C R Model RFC43 (SIN RA0612) Model RFC49 (SIN RA0616) R 11abi Residential Flat Concealed Sprinklers ` A Residential Flat Concealed Sprinkler engineered for a minimum .� • . design density of 0.05 gpm/ft2 with low GPM requirements. ' Features 1. Very low water flow requirements. 2. Cover plate attachment (Plain or Perforated) with 112" (13mm)Total adjustment. 3. Thread-0n/Thread-Off or Push-On/Thread Off cover attachment option. 4. Smooth aesthetic ceiling profile. 5. Available in brass, chrome and black plated or painted finishes. Listings & Approval 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) 2. NYC MEA 258-93-E UL Listing Categories Residential Automatic Sprinklers UL Guide Number J1 VKKW Product Description Model RFC30, RFC43 and RFC49 Concealed Residen- tial Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC30, RFC43 and RFC49 sprinklers discharge and positively attached and blends into the ceiling, con- water in a hemispherical pattern below the sprinkler de- flector. Residential distribution patterns are higher and cealing the most dependable fire protection available, an automatic sprinkler system. generally contain a finer droplet size than standard sprin- kler patterns. The RFC30, RFC43 and RFC49 are UL Listed Residen- The combination of speed of operation and high dis- tial Sprinklers to be installed in the residential portions charge pattern required for residential sprinklers has of any occupancy in accordance with NFPA 13, 13R, & demonstrated, in fire testing, an ability for controlling 13D. residential fires, and thereby providing significant evacu- The RFC30, RFC43 and RFC49 can reduce the need resid time for occupants. for precise cutting of drop nipples. The threaded cover ation RFC43 and RFC49 Sprinklers provide the plate assembly can be adjusted without tools to fit ac- The time for best form of fire protection by combining an attractive ap- curately against the ceiling. The fire protection system pearance and 112" (13mm) of cover adjustment for ease need not be shut down to adjust or remove the cover of installation. The small diameter cover plate is easily Plate assembly. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application and Installation The RFC30, RFC43 and RFC49, for residential instal- When inserting or removing the wrench from the sprin- lations, use a 165°F (74°C) fusible solder link in a tun- kler/cup assembly, care should be taken to prevent dam- ing fork style sprinkler frame with a drop-down deflector. age to the sprinkler. DO NOT WRENCH ON ANY OTHER This assembly is recessed into the ceiling and concealed PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL by a flat cover plate. The cover plate is attached to the RFC30, RFC43 AND RFC49 CONCEALED SPRINKLERS skirt, using 135°F(57°C)ordinary temperature classifica- MUST BE INSTALLED ONLY WITH 135°F RATED COV- tion solder.When the ceiling temperature rises,the solder ERS. holding the cover plate releases the cover allowing the Note:A leak tight 1/2" NPT(R1/2)sprinkler joint can be ob- deflector to drop into position and exposing the sprinkler tained with a torque of 8-18 ft-lbs(10,8-24,4 N-m). Do not inside to ceiling temperature. The subsequent operation tighten sprinklers over maximum recommended torque. It of the solder link opens the waterway and causes the de- may cause leakage or impairment of the sprinklers. flector to drop into position to distribute the discharging Cover assemblies provide up to 1/2" (13mm) of adjust- water in a hemispherical pattern below the sprinkler de- ment. Turn the cover clockwise until the flange is in con- flector. Any adjustment of thread engagement between tact with the ceiling. For the push-on/thread-off option, the cover plate and cup will assure that the drop-down the cover assembly is pushed onto the cup and final ad- deflector is properly located below the ceiling. The resi- justment is made by turning the cover clockwise until the dential distribution pattern contains a finer droplet size skirt flange makes full contact with the ceiling. Cover re- than a standard sprinkler, and the pattern produces sig- moval requires turning in the counter-clockwise direction. nificantly higher wall wetting. In ceilings that have a plenum space above the sprin- After a 2518 inch diameter hole is cut in the ceiling, the kler, the plenum space may have neutral or negative sprinkler is to be installed with the Model FC Wrench. pressurization but must not be positively pressurized. j When installing a sprinkler, the wrench is first positioned Inspect all sprinklers after installation to ensure that the into the sprinkler/cup assembly and around the hexago- gap between the cover plate and ceiling and the 4 slots nal body of the sprinkler frame. The Wrench must bottom in the cup are all open and free from any air flow impedi- out against the cup in order to ensure proper, safe instal- ment. lation. The sprinkler is then tightened into the pipe fitting. Thread Nominal Sprinkler CCP Assembly Max. Max. Model Temp Rat- Ambient K SIN Size Orifice ing Temp. Rating Temp. actor Pressure (SIN) p Inch(mm) Inch(mm) OF °C OF °C OF °C psi(bar) RFC (RA061 1) 1/2"(15) 21/,(8,2) 165 74 135 57 100 38 3.0 175(12) RFC (RA061 2) 1/2"(15) 3/b(10) 165 74 135 57 100 38 4.3 175(12) RFC 49 (RA0616) 112 (15) '/1s(11) 165 74 135 57 100 38 4.9 175(12) Note: 1 bar= 100 Kpa RFC 30 Ordinary Temp.Rating Max.Coverage 165°Fl74°C Minimum area Max.Spacing ( ) Spacing Ft x Ft(m x m) Ft(m) Flow Pressure Ft(m) GPM(Umin) PSI(bar) 12 x 12(3,6 x 3,6) 12(3,6) 9(34,1) 9.0(0,62) 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 10(37,8) 11.0(0,76) For Ceiling types refer to NFPA 13, 13R or 13D 2. RFC 43 Max.Coverage Ordinary Temp. Rating Minimum area Max.Spacing (155 F/68 C) Ft(m) Spacing Flow Pressure Ft x Ft(m x m) Ft(m) GPM(Umin) PSI(bar) 12 x 12(3,6 x 3,6) 12(3,6) 12(4,5) 7.8(0,54) 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 9.1 (0,63) 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 9.1 (0,63) 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 18(68) 17.5(1,21) 20x20(6,1 x6,1) 20(6,1) 21 (79) 23.8(1,64) For Ceiling types refer to NFPA 13, 13R or 13D RFC 49 Max.Coverage Ordinary Temp.Rating Minimum area Max.Spacing 155°F/68 0C Spacing Ft x Ft(m x m) Ft(m) Flow Pressure Ft(m) GPM(Uml n PSI bar 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0(0,48) 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48) 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 7.0(0,48) 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 17(69,3) 12.0(0,83) 20 x 20(6,1 x 6,1) 20(6,1) 20(75,73) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model RFC30, RFC43 and RFC49 Concealed Sprin- symmetric lever mechanism, maintaining a Teflon-coated klers should be inspected quarterly and the sprinkler Belleville spring washer and machined brass cap water system maintained in accordance with NFPA 25. Do not seal assembly containing no plastic parts. Sprinkler clean sprinklers with soap and water, ammonia or any K-factor shall be nominal 3.0(44), 4.3(62.4), and 4.91 other cleaning fluids. Remove dust by using a soft brush (70)having a 5/16", 3/8" and 7/16"orifice. Temperature rating or gentle vacuuming. Remove any sprinkler cover plate shall be Ordinary 165°F(74 0C); cover plate temperature assembly which has been painted(other than factory ap- rating to be 135°F(57°C). Cover plate assembly shall plied) or damaged in any way. A stock of spare sprin- consist of a brass cover plate and copper alloy retainer klers should be maintained to allow quick replacement flange allowing a 1/2" cover plate adjustment. Any secure of damaged or operated sprinklers. Prior to installation, engagement between the cover plate and the cup will sprinklers should be maintained in the original cartons assure that the drop-down deflector is properly located and packaging until used to minimize the potential for below the ceiling. A plastic protective cap shall be damage to sprinklers that would cause improper opera- provided and factory installed inside the sprinkler cup tion or non-operation. to protect the drop-down sprinkler deflector from dam- age,which could occur during construction before the Model RFC30, RFC43 and RFC49 Residential cover plate is installed. Standard cover finish: [Chrome] Concealed Sprinkler Specification [White] [Specialty-specify]. Residential concealed sprinklers shall be Reliable Model RFC30, SIN RA0611 Sprinklers shall be cULus Listed low flow residential con- (Bulletin 006), Model RFC43, SIN RA0612(Bulletin 006) cealed sprinklers with drop-down deflector and adjust- or Model RFC49, SIN RA0616(Bulletin 006). able flat cover plate engineered for a minimum design density of 0.05 gpm/ft2. Sprinkler frame and deflector shall be of bronze frame construction having a 112" NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with 3. Ordering Information Cover Plate Finishes0) Specify: Standard Finishes 1. Sprinkler Model Chrome 2. Cover Plate Finish White Paint _ 3. Thread-On or Special Application Push-On Feature Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi-gloss, unless specified CIO otherwise. (1)For the perforated style cover- plate,consult factory for avail- ability on these and other cus- tom finishes. 1" x 112" REDUCING TEE OR ELBOW 2j"[66.55mm] 2 "[58.42mm] DIA HOLE IN CEILING CUP [50.8mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING "[12.70mm] MAX. COVER ADJUSTMENT "[4.96mm] FLAT COVER PLATE ASSEMBLY "[84.21mm] DIA. SPRINKLER 006FC01e COVER PLATE: 1 12" L12. 7mml ADJUSTMENT The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. I Manufactured by Reliabilm The Reliable Automatic Sprinkler Co.,Inc. 19 Recycled (800)431-1588 Sales Offices Paper (800)848-6051 Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.05/13 PM 9999970261