Loading...
HomeMy WebLinkAboutB13-0271 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ,. 7�WN OF VAII, . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B13-0271 Project #: PRJ13-0190 Job Address: 2620 BALD MOUNTAIN RD VAIL Applied.....: 07/18/2013 Location......: UNIT B Issued. . . : 08/13/2013 Parcel No....: 210103403018 OWNER POPE, CAROLYN WOODWARD & STE 07/18/2013 17866 179TH TRL W LAKEVILLE, MN 550445205 CONTRACTOR MINICK CONSTRUCTION 07/18/2013 Phone: 970-904-5066 DAVID MINICK PO BOX 4018 � VAIL CO 81658 License: C000003535 APPLICANT POPE, CAROLYN WOODWARD & STE 07/18/2013 17866 179TH TRL W LAKEVILLE, MN '� 550445205 Description: REPLACE ALL FIRST AND SECOND FLOOR WINDOWS, REPAINT SIDING SAME COLOR, ADD A STONE WALL AND TRELLIS AT THE ENTRY AND ADD STONE ACCENT AROUND THE GARAGE DOORS. Occupancy: Type Construction: Valuation: $75,000.00 .............x.�......,..x.,.......,.........,..........,..,,,,,..,_..._..._..,_.. FEE SUMMARY ....................,,........=x...=...,..............,............<.......,..... _ > $1,300.00 Building Permit-----------> $818•75 Bldg Plan Check----------> $532.19 Use Tax Fee---------------------- Electrical Permit---------> $115.00 Elec Plan Check-----------> $74.75 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $0.00 Mech Plan Check---------> $0.00 Additional Fees--------------------� $0.00 Plumbing Permit--------> $0.00 Plmb Plan Check---------> $0.00 Recreation Fee--------------------� $0.00 Investigation-----------------------� $0.00 W ill Call -------------------------> $10.00 TOTAL PERMIT FEES--------------> $2,850.69 Payments-------------------------------> $2,850.69 BALANCE DUE------------------------> $0.00 ............x.................,���........�.......�,.......................................�....._........__...,...,,.....x...,x.,..x...,.....,..x..,,.......,.........x..=....�......,.x. DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4:00 PM. combination permit_012811 � � i Y���i� �� 1 . wM�kx#1rYf'�4fetr+FffYfw41(fYeRxletYrif4fe�k�RfkYrA'R1`L�.F+lwrtAeRrt�Frt%�Yr*f#�kk44f'A�*fkrtYew4feYewfrinFitwt`khRwRirx�/1`1`rt�R+tirwtritkx4#wY.ff4wxfLtwwMAYrf�i�i`rtf`4rtYtr*RkYrR*MYrRwlkfrtw*fYr1r*#+wx4rtYefiLRiFt*frtP't(4#Yrtl�ftRffY�kfLrtYrw44fwwf CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: 613-0271 Address: 2620 BALD MOUNTAIN RD VAIL Owner: POPE, CAROLYN WOODWARD &STEVEN Location: UNIT B `• ' wfyri(frtYf�R#�k�,FYrff#�Yrw1`1`RYrYfrt�F�kR4*!#fffrRf/Yf44YeYrf1�4#Yrw1`4Y'f*i`krtRf*#f:tf�YfRf1`1`Y'Rfi(Y`Y(*+#f�.Ffi(#�1r�R4#ff1r1`##Yrtrle�kY`Ye�Rx**frRt`4i1'Y`*R*trYr'R1`1rYrk444i�R1`kfYrlrRkwxl`feYrYeLftrNx*kRk4irM'�RkRk�kiF44fYe#t�1rYrRf'kY'f*rtYrRwirkrtfi#M�1ri4/� combination permit_012811 s � t V��U� 1�1tL * *«********«******.*««**********„**�*******.*,.*,,..******«***.********.**«*,.***«*******«*«******,+«««***«**,.�***,.*****************.*«,,.,***.*,.*«.*..«.**«.,* REQUIRED INSPECTIONS AND STATUSES � Permit#: 613-0271 Address: 2620 BALD MOUNTAIN RD VAIL Owner: POPE, CAROLYN WOODWARD & STEVEN Location: UNIT B *****«******,..*„**********«******************«*********************.,*****«****«****«*„***«******�*�,.,,***********�*********************«**�«*.******** Item: 00010 BLDG-FOOTING Item: 00020 BLDG-Foundation/Steel Item: 00120 ELEC-Rough Item: 00030 BLDG-Framing Item: 00190 ELEC-Final Item: 00070 BLDG-Misc. Item: 00090 BLDG-Final Item: 00542 PLAN-FINAL combination permit_012811 *+******************************+**************************************+******************** TOWN OF VAIL, COLORADOCopy Reprinted on 08-13-2013 at 15:03:40 08/13/2013 Statement ****************�****************************************�******************+*******+*****�* Statement Number: R130001180 Amount: 52, 243.75 08/13/201303:03 PM Payment Method: Check Init: CG Notation: ck 5346 minick construction ------------------------------------------------- Permit No: B13-0271 Type: COMBINATION BLDG PERMIT Parcel No: 2101-034-0301-8 Site Address: 2620 BALD MOUNTAIN RD VAIL Location: UNIT B Total Fees: $2, 850. 69 This Payment: $2,243.75 Total ALL Pmts: $2, 850. 69 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current-Pmts -------------------- ----------------------- BP 00100003111100 BUILDING PERMIT FEES 818.75 EP 00100003111100 ELECTRICAL PERMIT FEES 115.00 UT 11000003106000 USE TAX 4% 1, 300.00 WC 00100003112800 WILL CALL INSPECTION FEE 10.00 -------------------------------------------------- *************�**************�*************+�****************************�***************�*** TOWN OF VAIL, COLORADOCopy Reprinted on 07-18-2013 at 14:48:02 07/18/2013 Statement **�*****�*******+***********�***********�*+*********�**�************�********�**r********r*s Statement Number: R130001002 Amount: $606. 94 07/18/201302:47 PM Payment Method: Check Init: DR Notation: CK# 5318 DAVID MINICK ' ----------------------------------------------------------------------------- Permit No: B13-0271 Type: COMBINATION BLDG PERMIT I Parcel No: 2101-034-0301-8 i Site Address: 2620 BALD MOUNTAIN RD VAIL I Location: UNIT B ; Total Fees: $2, 850. 69 � This Payment: $606. 94 Total ALL Pmts: $606. 94 Balance: 52, 243.75 *******************************************+**��*****************�*********************+��** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 606. 94 ----------------------------------------------------------------------------- � I Department of Community Development 75 South Frontage Road TOWN OF VAIL` va�i,co 8�ss� Tel: 970-479-2128 ' www.vailgov.com ', Development Review Coordinator ' BUILDING PERMIT APPLICATION ' (Separate applications are required for alarm &sprinkler) , Project Street Address: Project#: '1'K�I.3— 0� 9� ' �D�A�4D /�IOGc�vTH-ini �D�D � SIrD� DRB#:�OC� ��7��c�`) cT�S. I'' (Number) (Street) (Suite#) , Building/Complex Name• Building Pennit#:s��,��p�� � I Contractor InformaUon Lot#: Block# Subdivision: ; � Business Name: L�tI�C� /9NS� iN� Business Address: �d��a 1� �1`D�� Work Class: New� Addition� Alteration�j City I/�/�� State:�Zi 5 Type of Building: P��_� Single-Family� Duplex� Multi-Family� Contact Name: __cQf►-(�t� !�'1[N�U� Commercial�j Other� : Contact Phone: �'!?G'— �(�5�—SOG G : . . _..:: _. _ _ _. : ;Contact E-Mail:� /�{�iU�(� Vi¢-l{oD � Cp�j Work Type: Interior�) Exterior� Both� I hereby adcnowledge that I have read this application,filled out Valuation of in full the information required,completed an accurate plot plan, Work Included Plans Included Work and state that all the information as required is correct. I agree to ElecErical �Yes Q)No Q)Yes �No �p�d_00 comply with the information and plot plan,to comply with all Town . -� — ordinances and state laws, and to build this structure according to .Mechanical ��jYes Q)No �jYes OjNo the town's zoning and subdivision codes, design review ap- proved,Intemational Building and Residential Codes and other Plumbing �jYes O)No QjYes �,�jNo ordinances of the Town applicable thereto. ' �Building �jYes Q)No QjYes �No �O� X Value of all work being performed: $ � ' Owner/Owne s Represent tive Signature(Required) -(value based on IBC Section 109.3 8 IRC Sedion 106.3� :Electrical Square Footage �i�TER,�OR` ..__-------_ p_ �.._... _ ___,. _._.___... _ . . ., _. _ ; Applicant Information Detailed Sco e and Location of Work:��o�.�,c'F t1LL �'OI.�-�ST � APPlicant Name: _�7t3 v(�� NI(�/I(`L �Lc�72 wlhiC�d�vS'_ �c�l��it4' �1451`rnn: S'l/�n� — Applicant Phone: °l?b—���fi ,�0 C� �(J�w L��e J—w,rvr�r � C,�Pi��,�r�xr. — APPlicantE-Mail: �k�"�iN�c,�c� �//�hva - cd�n 1�1PuJ 13(,OC=(�C �—St4wr` 1/'F �i? Sl� wrfLL.. SjC�f= Project Information G'C��Ei2��r(/Z.4LE s2,q/� —��i?j E�(r+ �.ICFF�S — Owner Name: C�pLI�N �DP�)S�EGE �pPt= ' / , Q,�',M,biO� aG�/ wcbcJ S(`�� Iq,��L{. — 'Parcel#:��` Q�y Q�(� � � ,(For Parcel#,contact Eagle Coun��Assessors Office at(970-328-8640 or visit N�-W �,���/(� �L n � www.eag lecou nty.uslpatie� - '(use additional sheet if necessary) For Oftic�Use Only: Date Received: � � � �. � � r���d: - (a�l�,9�I D FLeceived From: Cash Chedc# �U� �� �Q�� OC Vsa/ MC Last 4 CC# exp date: (1Q Auth# +�^1AIA' /��e�/�'R�� 11�.��IMIM �.If M��� 15-Mar-2012 - � I LINE NO. LOCATION BOOK CODE UNIT QTY EXTENDED SIZEINFO DESCRIPTION PRICE PRICE Line-10 101-Loft tempered RO Size:26 3/4 X 26 3/4 Frame Size : 26 X 26 i f,��4 (Outside Casing Size: 26 X 26) Custom Clad Awning,Auralast Pine, Viewed from Euterioa Scale:1/8^=r Chestnut Bronze Exterior-Kynar Finish, � Natural Interior, Nail Fin (Standard), No Sill Nosing, Standard DripCap, 3 3/8 Jamb, Venting, Nesting Crank Handle,Chestnut Bronze Hardware, Coastal Hardware, DP 50, Insulated Low-E EC Tempered Glass, Standard Spacer, High Altitude,Traditional Glz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop ��U-Factor: 0.30, SHGC: 0.24,VLT: 0.44, Energy Rating: 17.00, CPD: JEL-N-667-03449 -00001 Drawing Number: --Required! PEV 2013.1.1.622/PDV 5.789(02/08/13)PW $537.36 1 $537.36 Line-11 102, 103-Living Above CCCP4848 RO Size:48 3/4 X 48 3/4 Frame Size : 48 X 48 (Outside Casing Size: 48 X 48) Custom Clad Fixed Auralast Pine, Casement/Awning Product, Viewed from E�cterior.Scale:1/8°=i� Chestnut Bronze Exterior-Kynar Finish, Natural Interior, Nail Fin (Standard), No Sill Nosing, Standard DripCap, 3 3/8 Jamb, DP 35, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude,Traditional Glz Bd, Traditional Screen Stop U-Factor: 0.28, SHGC: 0.28,VLT: 0.51, Energy Rating: 21.00, CPD: JEL-N-669-05036 -00001 PEV 2013.1.1.62Z/PDV 5.789(02/OS/13)PW $583.98 2 $1,167.96 Line-12 104-Bed 2 CCC2872-2 RO Size:56 3/4 X 72 3/4 Frame Size : 56 X 72 � � (Outside Casing Size: 56 X 72) � •t Custom Clad Casement,Auralast Pine, 2 Wide � Chestnut Bronze Exterior-Kynar Finish, Natural Interior, � � Nail Fin (Standard), No Sill Nosing, Standard DripCap, Full Length Mull Cover, Viewed from Exterior.Scale:i/8^=i� Factory Mull, 3 3/8 Jamb, Left/Right, Sash Limiter, Coastal Hardware, Nesting Crank Handle,Chestnut Bronze Hardware, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude,Traditional Glz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop PEV 2013.1.1.622/PDV 5.789(02/08/13)PW $1,242.67 1 $1,242.67 QQ-2.13.1.1057 cust-o53179 Page 8 of 10(Prices are subjeCt to change.) ]BAwo9154-5/14/2013-7:52 PM Quote Date:4/18/2013 Drawings are for visual reference only and may not be to exact Last Modified:5/14/2013 scale. All orders are subject to review by JELD-WEN .. t 1 LINE NO. LOCATION BOOK CODE UNIT II QTY EXTENDED SIZEINFO DESCRIPTION PRICE PRICE Line-1 4-Garage DIM-CHGW4030 RO Size:45 3/4 X 32 3/4 (Outside Casing Size: 45 X 32) � Custom Clad 2W HGW ' Frame: 45 X 32 Viewed from Exterior.Scale:i/s°=r Chestnut Bronze-Kynar Finish,Chestnut Bronze Sash , Auralast Pine Natural Interior. ' Folding Nail Flange Standard DripCap, ', 4 9/16 Jamb Width. 4/4 ' Left i White Hardware W/Lifts Cam Lock(s) I IGW Int Glz Low-E EC Standard Color Spacer, Hi-Altitude Traditional Glz Bd, � No Grid � Chestnut Brz Scrn UltraVue Mesh � U-Factor: 0.29, SHGC: 0.26,VLT: 0.47, Energy Rating: 18.00, CPD: JEL-N-175-00462 -00001 i PEV 2013.1.1.622/PDV 5.789(02/08/13)PW I $634.82 1 $634.82 � i Line-2 il-Living Room CCC2454-2 ' RO Size:48 3/4 X 54 3/4 Frame Size : 48 X 54 (Outside Casing Size: 48 X 54) Custom Clad Casement,Auralast Pine, 2 Wide Chestnut Bronze Exterior-Kynar Finish, Natural Interior, Viewed from Exterior.Scale:1/8°=i� Nail Fin (Standard), No Sill Nosing, Standard DripCap, Full Length Mull Cover, Factory Mull, 3 3/8 Jamb, Left/Right, Coastal Hardware, Nesting Crank Handle, Chestnut Bronze Hardware, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude,Traditional Glz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop PEV 2013.1.1.622/PDV 5.789(02/OS/13)PW $985.87 1 $985.87 Line-2-1 (Al) CCC2454 RO Size:24 3/4 X 54 3/4 Frame Size : 24 X 54 (Outside Casing Size: 24 X 54) Custom Clad Casement,Auralast Pine, Chestnut Bronze Exterior-Kynar Finish, Natural Interior, Viewed from Exterior.scaie:i/s°=r Nail Fin (Standard), 3 3/8]amb, Hinge Left, Nesting Crank Handle, Chestnut Bronze Hardware, Coastal Hardware, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude, Traditional Glz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop Clear Opening:14.125w, 49.312h, 4.837 sf U-Factor: 0.30, SHGC: 0.25,VLT: 0.45, Energy Rating: 17.00, CPD: JEL-N-668- 05546-00001 QQ-2.13.1.1057 cust-053179 Page 2 of 10(Prices are subject to change.) JBAW09154-5/14/2013-7:52 PM Quote Date:4/18/2013 Drawings are for visual reference only and may not be to exact Last Modified:5/14/2013 scale. Alf orders are subject to review by]ELD-WEN � LINE NO. LOCATION BOOK CODE UNIT QTY EXTENDED SIZEINFO DESCRIPTION PRICE PRICE Line-2-2 (A2) CCC2454 RO Size:24 3/4 X 54 3/4 Frame Size : 24 X 54 � (Outside Casing Size: 24 X 54) I Custom Clad Casement,Auralast Pine, ! Chestnut Bronze Exterior-Kynar Finish, ' Natural Interior, ', Viewed from Exterioa Scale:1/8°=i� Nail Fin (Standard), � 3 3/8 Jamb, i Hinge Right, Nesting Crank Handle, Chestnut Bronze Hardware, Coastal Hardware, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude, Traditional Giz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop Clear Opening:14.125w,49.312h, 4.837 sf U-Factor: 0.30, SHGC: 0.25, VLT: 0.45, Energy Rating: 17.00,CPD: JEL-N-668- 05546-00001 Line-3 13,16-Dining VIF RO Size:34 1/4 X 60 3/4 Frame Size : 33 1/2 X 60 (Outside Casing Size: 33 1/2 X 60) Custom Clad Geometric,Auralast Pine, Direct Set Rectangle, Chestnut Bronze Exterior-Kynar Finish, Natural Interior, Viewed from Exterior.Scale:i/8^=i� Nail Fin (Standard), No Sill Nosing, Standard DripCap, 3 3/8 Jamb, Casement/Awning Detail, DP 35, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude, Traditional Screen Stop U-Factor: 0.27, SHGC: 0.29, VLT: 0.54, Energy Rating: 23.00, CPD: JEL-N-678-05771 -00001 PEV 2013.1.1.622/PDV 5.789(02/OS/13)PW $550.27 2 $1,100.54 Line-4 14,15-Dining VIF RO Size:73 1/4 X 60 3/4 Frame Size : 72 1/2 X 60 (Outside Casing Size: 72 1/2 X 60) Custom Clad Geometric,Auralast Pine, Direct Set Rectangle, Chestnut Bronze Exterior-Kynar Finish, Natural Interior, Viewed from Exterior,scaie:i/s^=i� Nail Fin (Standard), No Sill Nosing, Standard DripCap, 3 3/8 Jamb, Casement/Awning Detail, DP 35, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude, Traditional Screen Stop U-Factor: 0.26, SHGC: 0.29,VLT: 0.53, Energy Rating: 24.00, CPD: JEL-N-678-06026 -00001 PEV 2013.1.1.622/PDV 5.789(02/08/13)PW $931.96 2 $1,863.92 QQ-2.13.1.1057 cust-053179 Page 3 of 10(Prices are subject to change.) JBAW09154-5/14/2013-7:52 PM Quote Date:4/18/2013 Drawings are for visual reference only and may not be to exact Last Modified:5/14/2013 scale. All orders are subject to review by]ELD-WEN LINE NO. LOCATION BOOK CODE UNIT QTY EXTENDED SIZEINFO DESCRIPTION PRICE PRICE Line-5 17-Dining CCEC4060 RO Size:40 3/4 X 60 3/4 Frame Size : 40 X 60 I i � (Outside Casing Size: 40 X 60) � � Custom Epic Plus Clad Casement,Auralast Pine, /� Chestnut Bronze Exterior-Kynar Finish, l Natural Interior, i Viewed from Exterior.Scale:1/8^=1� Nail Fin (Standard), No Sill Nosing, Standard DripCap, j 3 3/8 Jamb, � Hinge Right, Sash Limiter, i Nesting Crank Handle,Chestnut Bronze Hardware, Coastal Hardware, DP 50, Insulated Low-E EC Annealed Glass, Standard Spacer, High Aititude,Traditional Glz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop U-Factor: 0.30, SHGC: 0.23,VLT: 0.42, Energy Rating: 16.00, CPD: JEL-N-829-00005 -00001 PEV 2013.1.1.622/PDV 5.789(02/OS/13)PW $894.24 1 $894.24 Line-6 18-Master Bedroom Main Line Item RO Size:128 1/4 X 46 1/4 Frame Size : 127 1/2 X 45 1/2 f � (Outside Casing Size: 127 1/2 X 45 1/2) � Custom Clad Muli Auralast Pine, Stack Mull,Casement/Awning Product, �, , Chestnut Bronze E�erior-Kynar Finish, viewed from Exterior.Scale:1/8"=i� Natural Interior, Nail Fin (Standard), No Sill Nosing, Standard DripCap, Full Length Mull Cover, 3 Wide 1 High, Factory Mull, 3 3/8 Jamb, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude,Traditional Glz Bd, Traditional Screen Stop PEV 2013.1.1.622/PDV 5.789(02/OS/13)PW $2,052.78 1 $2,052.78 QQ-2.13.1.1057 cust-053179 Page 4 of 10(Prices are subject to change.) ]BAW09154-5/14/2013-7:52 PM Quote Date:4/18/2013 Drawings are for visual reference only and may not be to exact Last Modified:5/14/2013 scale. All orders are subject to review by]ELD-WEN i � i LINE NO. LOCATION BOOK CODE UNIT QTY EXTENDED SIZEINFO DESCRIPTION PRICE PRICE I Line-6-1 (Al) RO Size:30 3/4 X 46 1/4 Frame Size : 30 X 45 1/2 j � (Outside Casing Size: 30 X 45 1/2) I Custom Clad Casement, Auralast Pine, ; `, Chestnut Bronze Exterior-Kynar Finish, j Viewed from Exterior.Scale:1/8°=r Natural Interior, '; Nail Fin (Standard), '� 3 3/8 Jamb, � Hinge Left, j Egress Hinge, Nesting Crank Handle, Chestnut Bronze Hardware, Coastal Hardware, DP 35, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude, Traditional Glz Bd, � UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop Clear Opening:22.5w,40.812h, 6.376 sf U-Factor: 0.30, SHGC: 0.25, VLT: 0.45, Energy Rating: 17.00, CPD: JEL-N-668- 05546-00001 Line-6-2 (A2) RO Size:68 1/4 X 46 1/4 Frame Size : 67 1/2 X 45 1/2 (Outside Casing Size: 67 1/2 X 45 1/2) Custom Clad Fixed Auralast Pine, Casement/Awning Product, Viewed from Exterior.Scale:1/8^=i� Chestnut Bronze Exterior-Kynar Finish, Natural Interior, Nail Fin (Standard), 3 3/8 Jamb, DP 35, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude, Traditional Glz Bd, Traditional Screen Stop U-Factor: 0.28, SHGC: 0.28,VLT: 0.51, Energy Rating: 21.00,CPD: )EL-N-669- 05036-00001 QQ-2.13.1.1057 cust-053179 Page 5 of 10(Prices are subject to change.) JBAW09154-5/14/2013-7:52 PM Quote Date:4/18/2013 Drewings are for visual reference only and may not be to exact Last Modified:5/14/2013 scale. AI�orders are subject to review by]ELD-WEN LINE NO. LOCATION BOOK CODE UNIT QTY EXTENDED SIZEINFO DESCRIPTION PRICE PRICE Line-6-3 (A3) RO Size:30 3/4 X 46 1/4 Frame Size : 30 X 45 1/2 � �� (Outside Casing Size: 30 X 45 1/2) I Custom Clad Casement,Auralast Pine, . Chestnut Bronze Exterior Kynar Finish, , Viewed from Exterior.Scale:i/s°=r Natural Interior, ' Naii Fin (Standard), � 3 3/8]amb, � Hinge Right, � Egress Hinge, Nesting Crank Handle, Chestnut Bronze Hardware, Coastal Hardware, , DP 35, ! Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude, Traditionai Glz Bd, I UltraVue Mesh Chestnut Bronze Screen,Traditionai Screen Stop Clear Opening:22.5w,40.812h, 6.376 sf U-Factor: 0.30, SHGC: 0.25,VLT: 0.45, Energy Rating: 17.00, CPD: JEL-N-668- 05546-00001 Line-7 19-Master Bed CCC3040-2 RO Size:60 3/4 X 40 3/4 Frame Size : 60 X 40 � � (Outside Casing Size: 60 X 40) Custom Clad Casement,Auralast Pine, 2 Wide Chestnut Bronze Exterior-Kynar Finish, Viewed from Exterior.Scale:1/8^=i� Natural Interior, Nai� Fin (Standard), No Sill Nosing, Standard DripCap, Full Length Mull Cover, Factory Mull, 3 3/8 Jamb, Left/Right, Coastal Hardware, Nesting Crank Handle, Chestnut Bronze Hardware, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude,Traditional Glz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop PEV 2013.1.1.622/PDV 5.789(02/OS/13)PW $949.61 1 $949.61 Line-7-1 (Ai) CCC3040 RO Size:30 3/4 X 40 3/4 Frame Size : 30 X 40 � (Outside Casing Size: 30 X 40) Custom Clad Casement,Auralast Pine, Chestnut Bronze Exterior-Kynar Finish, Viewed from Exterior.Scale:1/8°=i� Natural Interior, Nail Fin (Standard), 3 3/8 Jamb, Hinge Left, Nesting Crank Handle, Chestnut Bronze Hardware, Coastal Hardware, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude, Traditional Glz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop Clear Opening:20.125w, 35.312h, 4.935 sf U-Factor: 0.30, SHGC: 0.25, VLT: 0.45, Energy Rating: 17.00, CPD: JEL-N-668- 05546-00001 QQ-2.13.1.1057 cust-053179 Page 6 of 10(Prices are subject to change.) JBAW09154-5/14/2013-7:52 PM Quote Date:4/18/2013 Drawings are for visual reference only and may not be to exact Last Modified:5/14/2013 scale. All orders are subjed to review by]ELD-WEN LINE NO. LOCATION BOOK CODE UNIT QTY EXTENDED SIZEINFO DESCRIPTION PRICE PRICE Line-7-2 (A2) CCC3040 RO Size:30 3/4 X 40 3/4 Frame Size : 30 X 40 � (Outside Casing Size: 30 X 40) Custom Clad Casement,Auralast Pine, ; Chestnut Bronze Exterior-Kynar Finish, � Viewed from Euterioa Scale:i/8"=r Natural Interior, ; Nail Fin (Standard), ! 3 3/8 Jamb, ; Hinge Right, Nesting Crank Handle, Chestnut Bronze Hardware, Coastai Hardware, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude, Traditional Glz Bd, i UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop Clear Opening:20.125w, 35.312h,4.935 sf U-Factor: 0.30, SHGC: 0.25,VLT: 0.45, Energy Rating: 17.00, CPD: JEL-N-668- 05546-00001 Line-8 20-Stairs tempered RO Size:28 3/4 X 53 3/4 Frame Size : 28 X 53 (Outside Casing Size: 28 X 53) Custom Clad Casement,Auralast Pine, Chestnut Bronze Exterior-Kynar Finish, Natural Interior, Viewed from Exterior.Scale:i/8^=i� Nail Fin (Standard), No Sill Nosing, Standard DripCap, 3 3/8 Jamb, Hinge Left, Sash Limiter, Nesting Crank Handle, Chestnut Bronze Hardware, Coastal Hardware, DP 50, Insulated Low-E EC Tempered Glass, Standard Spacer, High Altitude,Traditional Glz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop U-Factor: 0.30, SHGC: 0.25,VLT: 0.45, Energy Rating: 17.00, CPD: JEL-N-668-05546 -00001 PEV 2013.1.1.622/PDV 5.789(02/OS/13)PW $689.40 1 $689.40 Line-9 21-Landing tempered RO Size:93 3/4 X 72 3/4 Frame Size : 93 X 72 (Outside Casing Size: 93 X 72) Custom Clad Geometric, Auralast Pine, Direct Set Rectangle, Chestnut Bronze Exterior-Kynar Finish, Natural Interior, Nail Fin (Standard), No Sill Nosing, Standard DripCap, Viewed from Exterior.Scale:1/8^=i� 3 3/8)amb, Casement/Awning Detail, DP 35, Insulated Low-E EC Tempered Glass, Standard Spacer, High Altitude, Traditional Screen Stop U-Factor: 0.26, SHGC: 0.28,VLT: 0.52, Energy Rating: 24.00,CPD: ]EL-N-678-06111 -00001 PEV 2013.1.1.622/PDV 5.789(02/OS/13)PW $1,803.88 1 $1,803.88 QQ-2.13.1.1057 cust-053179 Page 7 of 10(Prices are subject to change.) JBAW09154-5/14/2013-7:52 PM Quote Date:4/18/2013 Drawings are for visual reference only and may not be to exact Last Modified:5/14/2013 scale. All orders are subject to review by JELD-WEN LINE NO. LOCATION BOOK CODE UNIT QTY EXTENDED SIZEINFO DESCRIPTION PRICE PRICE Line-12-1 (Ai) CCC2872 RO Size:28 3/4 X 72 3/4 Frame Size : 28 X 72 � (Outside Casing Size: 28 X 72) � J Custom Clad Casement,Auralast Pine, � Chestnut Bronze Exterior-Kynar Finish, � Natural Interior, i Naii Fin (Standard), ! Viewed from Exterior.Scale:1/8°=i� 3 3/8 Jamb, � Hinge Left, Sash Limiter, Nesting Crank Handle,Chestnut Bronze Hardware, Coastal Hardware, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude, Traditional Glz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop U-Factor: 0.30, SHGC: 0.25,VLT: 0.45, Energy Rating: 17.00, CPD: JEL-N-668- 05546-00001 Line-12-2 (A2) CCC2872 RO Size:28 3/4 X 72 3/4 Frame Size : 28 X 72 � (Outside Casing Size: 28 X 72) •� Custom Clad Casement,Auralast Pine, Chestnut Bronze 6cterior-Kynar Finish, Natural Interior, � Nail Fin (Standard), Viewed from Enterior.Scale:i/8°=i� 3 3/8 Jamb, Hinge Right, Sash Limiter, Nesting Crank Handle,Chestnut Bronze Hardware, Coastal Hardware, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude, Traditional Glz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop U-Factor: 0.30, SHGC: 0.25,VLT: 0.45, Energy Rating: 17.00, CPD: JEL-N-668- 05546-00001 Line-13 105,106-Bedrooms Main Line Item RO Size:56 3/4 X 44 3/4 Frame Size : 56 X 44 � � (Outside Casing Size: 56 X 44) Custom Clad Casement, Auralast Pine, 2 Wide \ Chestnut Bronze Exterior-Kynar Finish, Viewed from Exterior.Scale:1/8^=i� Natural Interior, Nail Fin (Standard), No Sill Nosing, Standard DripCap, Full Length Mull Cover, Factory Mull, 3 3/8)amb, Left/Right, Coastal Hardware, Nesting Crank Handle, Chestnut Bronze Hardware, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude,Traditional Glz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop PEV 2013.1.1.622/PDV 5.789(02/08/13)PW $1,130.13 2 $2,260.26 QQ-2.13.1.1057 cust-053179 Page 9 of 10(Prices are subject to change.) ]BAW09154-5/14/2013-7:52 PM Quote Date:4/18/2013 Drewings are for visual reference only and may not be to exact Last Modified:5/14/2013 scale. All orders are subjed to review by JELD-WEN 1 i LINE NO. LOCATION BOOK CODE UNIT QTY EXTENDED SIZEINFO DESCRIPTION PRICE PRICE Line-13-1 (A1) RO Size:28 3/4 X 44 3/4 Frame Size : 28 X 44 i � (Outside Casing Size: 28 X 44) � � Custom Clad Casement,Auralast Pine, ♦ Chestnut Bronze Exterior-Kynar Finish, Viewed from Exterior.Scale:1/8°=i� Natural Interior, Nail Fin (Standard), 3 3/8 Jamb, Hinge Left, Egress Hinge, Nesting Crank Handle, Chestnut Bronze Hardware, Coastal Hardware, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude, Traditional Glz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop Clear Opening:20.5w, 39.312h, 5.596 sf U-Factor: 0.30, SHGC: 0.25, VLT: 0.45, Energy Rating: 17.00, CPD: JEL-N-668- 05546-00001 Line-13-2 (A2) RO Size:28 3/4 X 44 3/4 Frame Size : 28 X 44 �\ (Outside Casing Size: 28 X 44) J Custom Clad Casement,Auralast Pine, � Chestnut Bronze F�cterior-Kynar Finish, Viewed from Exterior.Stale:1/8^=i� Natural Interior, Nail Fin (Standard), 3 3/8 Jamb, Hinge Right, Egress Hinge, Nesting Crank Handle,Chestnut Bronze Hardware, Coastal Hardware, Insulated Low-E EC Annealed Glass, Standard Spacer, High Altitude, Traditional Glz Bd, UltraVue Mesh Chestnut Bronze Screen,Traditional Screen Stop Clear Opening:20.5w, 39.312h, 5.596 sf U-Factor: 0.30, SHGC: 0.25, VLT: 0.45, Energy Rating: 17.00, CPD: JEL-N-668- 05546-00001 Total: $16,183.31 Eagle County Tax(1.5%) $242.75 CO State tax(2.9%) $469.32 NET TOTAL: $16,895.38 Total Units: 17 Note: Please be advised this is a Non-Stock, Non-Returnable, Special order product. Your signature below indicates you have reviewed the specifications, quantities, and details of this order. Samples have been made available for your review. ABWD makes no expressed or implied warranties including no warranties of inerchantability,fitness or fitness for a particular purpose and the Buyer shall rely solely on the warranties provided by manufacturer. X QQ-2.13.1.1057 cust-053179 Page 10 of 10(Prices are subjed to change.) JBAW09154-5/14/2013-7:52 PM Quote Date:4/18/2013 Drawings are for visual reference only and may not be to exact Last Modified:5/14/2013 scale. All orders are subject to review by]ELD-WEN • • � /l 12-06-2013 Inspection Request Reporting Page 22 4:01 pm Vail, CO - City Of i3' OtH V Requested Inspect Date: Monday,December 09,2013 Site Address: 2620 BALD MOUNTAIN RD VAIL UNIT B A/P/D Information Activity B13-0271 Type: COMBO Sub Type: OTHER Status: ISSUED Const Type Occupancy: Use: R-3 Insp Area: Owner POPE,CAROLYN WOODWARD&STEVEN Contractor: MINICK CONSTRUCTION Phone: 970-904-5066 Description: REPLACE ALL FIRST AND SECOND FLOOR WINDOWS REPAINT SIDING SAME COLOR ADD A STONE WALL AND TRELLIS AT THE ENTRY AND ADD STONE ACCENT AROUND THE GARAGE DOORS. Requested Inspection(s) Item 542 PLAN-FINAL Requested Time: 08:00 AM Requestor MINICK CONSTRUCTION Phone: 970-904-5066 Comments 904-5066 Assigned To GRUTHER Entered By: JMONDRAGON K Action Time Exp: hem 90 BLDG-Final Requested Time: 02:30 PM Requestor MINICK CONSTRUCTION Phone: 970-904-5066 Comments 904-506. Assigned To S- ' !ER Entered By: JMONDRAGON K Action �;5, Time Exp: Item• 190 ELEC-Final Requested Time: 01:00 PM Requestor MINICK CONSTRUCTION Phone: 970-904-5066 Comments 904-5066 . Assigned To SGRE ,i;R Entered By: JMONDRAGON K Action i. Time Exp: Item• 290 •LMB-Final Requested Time: 01:30 PM Requestor MINICK CONSTRUCTION Phone: 970-904-5066 Comments 904-5066 Assigned To SG' M Entered By: JMONDRAGON K Action r., • Time Exp: Item• 390 MECH-Final Requested Time: 02:00 PM Requestor MINICK CONSTRUCTION Phone: 970-904-5066 Comments 904-506. Assigned To SG y'?�, Entered By: JMONDRAGON K Action Time Exp: \I• l Ckk3 4' Inspection History Item: 10 BLDG-FOOTING **Approved** 09/03/13 Inspector: JRM Action: AP APPROVED Comment: Item: 20 BLDG-Foundation/Steel **Approved** 10/15/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 220 PLMB-Rough/D.W.V. **Approved** REPT131 Run Id: 14723 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ,. 1�WN OF YAA.'' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B13-0271 Project #: PRJ13-0190 Job Address: 2620 BALD MOUNTAIN RD VAIL Applied.....: 07/18/2013 Location......: UNIT B Issued. . . : 10107/2013 Parcel No....: 210103403018 OWNER POPE, CAROLYN WOODWARD & STE 07/18/2013 17866 179TH TRL W LAKEVILLE, MN 550445205 CONTRACTOR MINICK CONSTRUCTION 07/18/2013 Phone: 970-904-5066 DAVID MINICK PO BOX 4018 � VAIL CO 81658 License: C000003535 APPLICANT POPE, CAROLYN WOODWARD & STE 07/18/2013 17866 179TH TRL W LAKEVILLE, MN 550445205 Description: REPLACE ALL FIRST AND SECOND FLOOR WINDOWS, REPAINT SIDING SAME COLOR, ADD A STONE WALL AND TRELLIS AT THE ENTRY AND ADD STONE ACCENT AROUND THE GARAGE DOORS. Occupancy: R-3 Type Construction: VB Valuation: $75,000.00 .....,,..,..,..........................................�.......,...,_.,....,,...... FEE SUMMARY .,,....._,...,.,,...,..,,...�..........,.,..........,........<.,..,..........<.... Building Permit-----------> $846.75 Bldg Plan Check----------> $550.39 Use Tax Fee-----------------------> $1,300.00 Electrical Permit---------> $258.75 Elec Plan Check-----------> $168.19 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $0.00 Mech Plan Check---------> $0.00 Additional Fees--------------------> $237.00 Plumbing Permit--------> $75.00 Plmb Plan Check---------> $18.75 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $10.00 TOTAL PERMIT FEES--------------> $3,464.83 � Payments-------------------------------> $3,464.83 BALANCE DUE------------------------> $0.00 ...�..............�.,.,.,.......,.>.,...,...,...,,>„<.....,.....,..,�......,.........,,....,......,....................�.........._.....�.�._........:.........................,..,�...«... DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4:00 PM. combination permit_012811 , � r ��iN i!��� Y ..xx.«.«...•.x>......+..:+....<+......++.......>.+....:........x.+.+.++•..x......++.e++......+.....+..:r.....•...w.xxx+....:..+++.,+r....+.exxx.w....x++«•..>:.....x++.....+......x+.... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF � Permit#: 613-0271 Address: 2620 BALD MOUNTAIN RD VAIL Owner: POPE, CAROLYN WOODWARD & STEVEN Location: UNIT B ,...>...................................��,,,.....�.....,......,,...x,.......,..,.......,...,,�...........,.......,.............x....�..........,...........,.,..,,,......,.,......... � combination permit_012811 I � # T��N QF VA� ' ****,,.************.,*****..**.�**************.*****.***********************�,.�*********.,.********�****�***********�*********,***********.******�******* REQUIRED INSPECTIONS AND STATUSES � Permit#: 613-0271 Address: 2620 BALD MOUNTAIN RD VAIL Owner: POPE, CAROLYN WOODWARD & STEVEN Location: UNIT B *«*«**.,.,*,,,.*.,*«.,*.*.*.,«******************.**********«.,************.,***«**.,.*.*«*«****�******.,*******,,.**�*****.,«*«*,.****************�**«*.**.,*.*****« Item: 00010 BLDG-FOOTING 09/03/2013 By: JRM Action: AP Item: 00020 BLDG-Foundation/Steel Item: 00220 PLMB-Rough/D.W.V. Item: 00230 PLMB-Rough/Water Item: 00200 MECH-Rough Item: 00120 ELEC-Rough Item: 00030 BLDG-Framing 09/16/2013 By: JRM Action: AP Item: 00190 ELEC-Final Item: 00070 BLDG-Misc. Item: 00290 PLMB-Final Item: 00390 MECH-Final Item: 00090 BLDG-Final Item: 00542 PLAN-FINAL combination permit_012811 ******************************************+*************+********�*+********�*+************* TOWN OF VAIL, COLORADOCopy Reprinted on 10-07-2013 at 14:32:19 10/07/2013 Statement ******************************************************************************************** Statement Number: R130001639 Amount: $614 . 14 10/07/201302:32 PM Payment Method: Check Init: CG Notation: ck 5393 minick construction ----------------------------------------------------------------------------- Permit No: B13-0271 Type: COMBINATION BLDG PERMIT Parcel No: 2101-034-0301-8 Site Address: 2620 BALD MOUNTAIN RD VAIL Location: UNIT B Total Fees: $3, 464 .83 This Payment: $614 . 14 Total ALL Pmts: $3, 464 .83 Balance: $0.00 **************************************************************************+***************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BOILDING PERMIT FEES 28 . 00 EP 00100003111100 ELECTRICAL PERMIT FEES 143.75 PF 00100003112300 PLAN CHECK FEES 130. 39 PP 00100003111100 PLUMBING PERMIT FEES 75.00 UT 11000003106000 DSE TAX 40 232.00 WC 00100003112800 WILL CALL INSPECTION FEE 5.00 -----------------------------------------------------------------------------