HomeMy WebLinkAboutA13-0043 DATA SHEETS.pdf DF-52418:D•Al-20 MS-90SOUD(E) FMIITerALaf ms Fire Alarm Control Panel with DACT by Honeywell Addressable General The Fire•Lite MS-9050UD(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. This compact, intelligent addressable control panel supports up to 50 addressable devices of any type of detectors and modules. With an exten- sive list of powerful features,the MS-905OUD programs just like Fire-Lite's larger products, yet fits into applications previously served only by conventional panels. The MS-9050UD's integral DACT transmits system status (alarms,troubles,AC loss,etc.)to a Central Station via the pub- lic switched telephone network. It also allows remote and local programming of the control panel using the PK-CD Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Wind owsT 95 or o greater, and compatible modem with a speed of 14.4 kbps or faster and Fire-Lite Upload/Download software kit PK-CD, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walk-test data,current status and system voltages. • Point trouble identification. The power supply and all electronics are contained on a single • Waterflow selection per module point. circuit board supported on a new quick install chassis and . Alarm verification selection per detector point. housed in a metal cabinet. Available accessories include local . Maintenance alert warns when smoke detector dust accumu- and remote upload/download software, remote annunciators, lation is excessive. and reverse polarity/city box transmitter. (4XTMF) One-person audible or silent walk test with walk-test log and New options include a UL listed printer, PRN-6F and the new printout. IPDACT Internet Monitoring module.The FireWatch Series inter- . System alarm verification selection per detector point. net monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet,saving the monthly PAS (Positive Alarm Sequence) and Pre signal per point cost of two telephone lines. Although not required, the second- (NFPA 72 compliant). ary telephone line may be retained providing backup communi- • Up to eight ANN-BUS annunciators cation over the public switched telephone line. • Remote Acknowledge, Alarm Silence, Reset and Drill via NOTE: Unless otherwise specified, the term MS-905OUD is used addressable modules or remote annunciator. in this data sheet to refer to both the MS-905OUD and the MS- • Upload/Download (local or remote) of program and data via 905OUDE FACPs. For MS-9050UDC,refer to DF-60445. integral DACT. Features SLC COMMUNICATION LOOP Listed to UL Standard 864,9th edition. • Single addressable SLC loop which meets NFPA Style 4, 6 • and 7 requirements. • Auto-program (learn mode) reduces installation time. . 50 addressable device capacity(any combination of address- Reports two devices set to the same address. able detectors and modules). • On-board DACT. • Compatible with Fire-Lite's addressable devices(refer to SLC • Two independently programmable Style Z (Class A) or Style Wiring Manua/). Y(Class B)NAC circuits. • Selectable strobe synchronization for System Sensor,Whee- NOTIFICATION APPLIANCE CIRCUITS(NA CS) lock,and Gentex devices. Two independently programmable output circuits. Circuits • Remote Acknowledge, Silence, Reset and Drill via address- can be configured for the following outputs: able monitor modules. —Style Y(Class B) • Two programmable relays and one fixed trouble relay. —Style Z(Class A) • Built-in Programmer. –Door Holder Service(cannot be used for notification appliances) • Telephone Line Active LEDs. –Aux Power Source(cannot be used for notification appliances) • EIA-232 PC interface. Silence Inhibit and Autosilence timer options. • Integral 80-character LCD display with backlighting. Continuous, March Time, Temporal or California code for • Real-time clock/calendar with automatic daylight savings main circuit board NACs with two-stage capability. control. Selectable strobe synchronization per NAC. • History file with 500 event capacity. 2.5 A total power for NACs. • Automatic detector sensitivity testing(NFPA 72 compliant). NOTE: Maximum or total 24VDC system power shared between • Automatic device type-code verification. all NAC circuits and the ANN-BUS is 2.7 A. DF-524180•02/22/2011—Page 1 of 4 PROGRAMMING AND SOFTWARE • Autoprogram (learn mode) reduces installation time. • Custom English labels (per point) may be manually entered or selected from an internal library file. • Two programmable Form-C relay outputs. • 20 software zones. • Continuous fire protection during online programming at the front panel. MS-9050UD • Program Check automatically catches common errors not Fire Alarm linked to any zone or input point. Control Panel • OFFLINE PROGRAMMING: Create the entire program in ANN 80 your office using a Windows®-based software package(order programming kit PK-CD, containing PK-Plus, separately). Upload/download system programming locally. SD355 Printer User interface Photo Detector Gateway LED INDICATORS ANN-S/PG • AC Power(green) • Fire Alarm (red) • Supervisory(yellow) AD355 Graphic LED Module • Trouble(yellow) Adapt Detector ANN-I/0 • Alarm Silenced signals(yellow) KEYPAD • 16 key alpha-numeric pad H355/H355R/H355HT Relay Module • Acknowledge/Step Heat Detector ANN-RLY P2R • Alarm Silenced Strobe • Drill(Manual Evacuate) • Reset(lamp test) MDF-300 Product Line Information Dual Monitor Module P2R MS-9050UD(E): Combination DACT/Fire Alarm Control Panel Strobe with one SLC loop. Includes main circuit board with display, Power Supply chassis with transformer,backbox with door,plastic bag contain- C FCPS-24FS6 ing screws, cables, key, etc., manual. (For MS-9050UDC, refer . FCPS-24FS8 <; S0355T to DF-60445.) Photo/Thermal P2R PK-CD: Contains PK-Plus programming software for Win- Strobe dows®-based PC computer(cable not included). ,F#_�u DP-51050:Optional dress panel for the MS-9050UD. Multi-Modules TR-CE:Optional trim ring for semi-flush mounting. MMF-300 . CRF-300-6 Six-Relay Control Module BB-2F:Optional cabinet for one or two modules. Monitor Module . CMF-300-6 Six-Circuit Supervised Control Module BB-6F: Optional cabinet for up to six modules mounted on • MMF-302-6 Six-Zone Interface Module CHS-6 chassis. • MMF-300-10 Ten-Input Monitor Module BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. MMF-302 BB-55F: Battery box, houses two 55 AH batteries 2-Wire Detector Monitor Module CHS-6: Chassis, mounts up to six multi-modules in a BB-6F cabinet. I[ CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. D355PL Beam Detector CHG-120F: Remote battery charging system for lead-acid bat- Duct Detector BEAM-335/(S) teries with a rating of 55 to 120 AH. Requires additional BB-55F for mounting. 0 MS-9050UD BAT Series: Batteries,see data sheet DF-52397. PRT/PK-CABLE: Cable printer/personal computer interface ADDRESSABLE FIRE ALARM cable. CONTROL PANEL PRN-6F: UL listed compatible event printer. Uses tractor-fed BG-12LX Addressable paper. Manual Pull Station IPDACT, IPDACT 2/2UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether- Page 2 of 4—DF-524180•02/22/2011 net internet connection. Requires compatible Teldat Visoralarm 4.0"(10.16 cm.)box. Includes plastic cover plate and end-of-line Central Station Receiver. Can use DHCP or static IP. (See data resistor.Module may be configured for either a Style B(Class B) sheet df-52424 for more information.) or Style D(Class A) IDC. IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. MDF-300: Dual Monitor Module. Same as MMF-300 except it IPSPLT:Y-adaptor option allows connection of both panel dialer provides two Style B(Class B)only IDCs. outputs to one IPDACT-2/2UD cable input. MMF-301: Miniature version of MMF-300. Excludes LED and AC-TRMBLK: AC Terminal Block mounts to a metal bracket, in Style D option. Connects with wire pigtails. May mount in device turn, mounts to the FACP chassis. Use AC-TRMBLK when wire backbox. nuts are not allowed for AC connections to the transformer. MMF-302A:Similar to MMF-300A.Addressable Monitor Module for one zone of conventional two-wire detectors. Requires reset- OPTIONAL MODULES table 24 VDC power. Refer to the Device Compatibility Docu- 4XTMF Reverse Polarity Transmitter Module: Provides a ment for listed compatible devices and quantity limitation. supervised output for local energy municipal box transmitter, CMF-300:Addressable Control Module for one Style Y/Z(Class alarm and trouble. Includes a disable switch and disable trouble B/A) zone of supervised polarized Notification Appliances. LED. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification ANN-SEC: Optional secondary ANN-BUS interface module. Appliance Circuit option requires external 24 VDC to power noti- Note:Used only with firmware 3.0 or higher. fication appliances. COMPATIBLE ANNUNCIATORS CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. ANN-80(-W): Remote LCD annunciator mimics the information Mounts directly to a 4.0" (10.16 cm.) box, surface mount using displayed on the FACP LCD display. Recommended wire type is the SMB500. un-shielded.(Basic model is red;order-W version for white;see BG-12LX: Addressable manual pull station with interface mod- DF-52417.) ule mounted inside. ANN-1/0: LED Driver Module provides connections to a user 1300:This module isolates the SLC loop from short circuit condi- supplied graphic annunciator. (See DF-52430.) tions(required for Style 6 or 7 operation). ANN-LED: Annunciator Module provides three LEDs for each SMB500: Used to mount all modules except the MMF-301 and zone: Alarm, Trouble, and Supervisory. Ships with red enclo- M301. sure. (See DF-60241.) ANN-REED: Provides alarm (red) indicators for up to 30 input MMF-300-10:Ten-input monitor module. Mount one or two mod- zones or addressable points. (See DF-60241.) ules a cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. ANN-RLY: Relay Module provides 10 programmable Form-C MMF-302-6: Six-zone interface module.Mount one or two mod- relays. Can be mounted inside the cabinet. (See DF-52431.) ules in a BB-2F cabinet(optional). Mount up to six modules on a ANN-S/PG: Serial/Parallel Printer Gateway module provides a CHS-6 chassis in a BB-6F cabinet. connection for a serial or parallel printer. (See DF-52429.) CMF-300-6:Six-circuit supervised control module.Mount one or ADDRESSABLE DEVICES two modules in a BB-2F cabinet(optional).Mount up to six mod- All feature a polling LED and rotary switches for addressing. ules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six-relay control module (Form-C relays). Mount CP355:Addressable low-profile ionization smoke detector. one or two modules in a BB-2F cabinet (optional). Mount up to SD355:Addressable low-profile photoelectric smoke detector. six modules on a CHS-6 chassis in a BB-6F cabinet. SD355T: Addressable low-profile photoelectric smoke detector NOTE:For more information on Compatible Addressable Devices with thermal sensor. for use with the MS-9050UD, see the following data sheets(docu- SD355R: Remote test capable addressable photoelectric ment numbers):AD355(DF-52386), BG-12LX(DF-52013), CMF- smoke detector for use with DNR(W)duct detector housing. 300-6(DF-52365), CRF-300-6(DF-52374), CMF/CRF Series(DF- 52130), CP355 (DF-52383), H355 Series (DF-52385), 1300 (DF- H355: Fast-response, low-profile heat detector. 52389), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 H355R: Fast-response, low-profile heat detector with rate-of- (DF-52347), MMF-302-6 (DF-52356), SD355ISD355T (DF- rise option. 52384). H355HT: Fast-response, low-profile heat detector that activates ADDRESSABLE DEVICE ACCESSORIES at 190°F/88°C. End-of-Line Resistor Assembly (R-47K and R-3.9K): The AD355: Low-profile, intelligent, "Adapt' multi-sensor detector 47k ohm assembly supervises the MMF-300, MDF-300, MMF- (B350LP base included). 301, and CMF-300 module circuits. The 3.9k ohm assembly BEAM355: Intelligent beam smoke detector. supervises the MMF-302 module circuit. These resistors are BEAM355S: Intelligent beam smoke detector with integral sen- included with each module. sitivity test. Power Supervision Relay: Supervises the power to 4-wire D355PL: InnovairFlex low-flow non-relay duct-detector housing; smoke detectors and notification appliances. includes SD355R. DNR: InnovairFlex low-flow non-relay duct-detector housing. Wiring Requirements (Order SD355R separately.) While shielded wire is not required, it is recommended that all DNRW: InnovairFlex low-flow non-relay duct-detector housing, SLC wiring be twisted-pair to minimize the effects of electrical with NEMA-4 rating. Watertight. (Order SD355R separately.) interference. Refer to the panel manual for wiring details. MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard DF-524180•02/22/2011—Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic compo- • Intelligent Signalling Line Circuits......................................... 1 nents may be adversely affected by extreme temperature ranges • Addressable device capacity..............................................50 and humidity. Therefore,it is recommended that this system and • Programmable software zones...........................................20 its peripherals be installed in an environment with a normal room • Annunciators.........................................................................8 temperature of 15—27°C/60—80°F. Electrical Specifications NFPA Standards AC Power: MS-905OUD 120 VAC,60 Hz, 3.0 A. MS-905OUDE: The MS-9050UD(E) complies with the following NFPA 72 Fire 240 VAC,50 Hz, 1.5 A.Wire size:minimum 14 AWG(2.00 mm2) Alarm Systems requirements: with 600 V insulation. Nonpower-limited,supervised. —LOCAL (Automatic, Manual, Waterflow and Sprinkler Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Supervisory). Capacity: 7-18 AH (MS-9050UD cabinet holds maximum of two —AUXILIARY (Automatic, Manual and Waterflow) (requires 18 AH batteries.) 4XTMF). Communication Loop: Supervised and power-limited. —REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and Notification Appliance Circuits: Terminal Block provides con- supervisory relays may be connected to UL 864 listed nections for two NACs, Style Y (Class B) or Style Z (Class A). transmitters. For reverse polarity signaling of alarm and Special Application power. Power-limited, supervised circuitry. trouble,4XTMF is required.) Maximum signaling current per circuit:2.5 A. End-of-Line Resis- —PROPRIETARY(Automatic, Manual and Waterflow). tor:4.7k ohm,1/2 watt(P/N 71252 UL listed)for Style Y(Class B) NAC. Refer to the Fire-Lite Device Compatibility Document for —CENTRAL STATION (Automatic, Manual and Waterflow, listed compatible devices. and Sprinkler Supervised). Two Programmable Relays and One Fixed Trouble Relay: —OT, PSDN (Other Technologies, Packet-switched Data Net- Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC work) (resistive). Form-C relays, nonpower-limited, nonsupervised. Agency Listings and Approvals Cabinet Specifications The listings and approvals below apply to the basic MS- Door: 19.26"(48.92 cm.) high x 16.82" (42.73 cm.)wide x 0.72" 9050UD(E) control panel. In some cases, certain modules may (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" not be listed by certain approval agencies, or listing may be in (42.29 cm.)wide x 5.25" (13.34 cm.)deep.Trim Ring(TR-CE): process.Consult factory for latest listing status. 22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • UL: S624 • FM approved Shipping Specifications • CSFM:7165-0075:210 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) • MEA:442-06-E high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. NOTE:See DF-60445 for ULC-listed model. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49°C/32—120°F and at a relative humidity 93%±2%RH (non- FireLite@ Alarms@ and System Sensor@ are registered trademarks of Honeywell International Inc. Microsoft@ and Windows@ are registered trademarks of the Microsoft Corporation. 02011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 4 of 4—DF-524180•02/22/2011 •i, CS P R 0 D U C T I N F 0 R M A T 1 0 N B U L L E T I N 449 / 448 SERIES Self-Diagnostic, Four- Wire, Photoelectric Smoke Detectors Model numbers: 449AT,449C,449CT,449CRT,449CST,449CSTE, ,. 449CSRT,449CSRH,449CTE LISTED APPROVED California State Fire Marshal Approved MEA(New York City)Approved ULC model numbers: 448AT,448C,448CT,448CST,448CSRH,448CTE • Intelligent, self-diagnostics The ESL 449/448 Series self-diagnostic, four-wire smoke detectors continually monitor their own • On-site maintenance alert sensitivity and operational status, and provide a visual trouble indication if they drift out of sensitivity • Field replaceable optical chamber range or fail internal diagnostics. This unique, • Low-profile design patented technology meets NFPA 72 field sensitivity testing requirements without the need for external • Plug-in terminal block meters. Additional diagnostic information is activated by • Advanced false alarm immunity applying a magnet near the detector's integral reed switch. This initiates a self-diagnostic routine and provides visual indication of sensitivity level, or if service is required. This series is easily cleaned by simply replacing ESL's proprietary field-replaceable optical chamber. All models are designed to reduce false alarms from dust, insects, RFI, and external light. An integral combination rate-of-rise and fixed 135°F (57°C), 50-foot rated, heat sensor is available with all "T" model detectors (see selection guide), allowing latching of the alarm for either smoke or heat. The 449CSRH includes an isolated alarm output for heat and activates an internal non-latching sounder (local alarm) for smoke, making it ideal for motel/hotel and dormitory rooms where smoking is permitted. continued ESL 449 Series Smoke Detectors Architectural and Engineering Specifications The ESL 449 Series low-profile, self-diagnostic,four-wire The proprietary optical sensing chamber is field replaceable, smoke detectors work on the light scattering principle.A allowing quick and easy cleaning and maintenance. pulsed infrared light-emitting diode serves as the light source, Models with auxiliary relays are approved for releasing and a high-speed photodiode as the sensing element. When service. the amount of light reflected onto the photodiode reaches the This low profile product is equipped with a hinged cover, a sensitivity setting,the smoke sampling rate increases. Three concealed tamper-resistant latch, and insect screens. (3)successive smoke sensings above the sensitivity setting Wiring terminates in plug-in, clamp-type screw terminals. are required to sound an alarm.This design has superior Detectors mount to a standard single-gang electrical box, a protection against false alarms caused by dust, insects, RF four-inch octagonal,four-inch square electrical box, or and ambient-light. WIREMOLD 5739 fixture box. A confirmed alarm causes the normally flashing power Smoke Detector Spacing indicator LED to light continuously and the alarm relay to On smooth ceilings(as defined in NFPA 72),spacing of 30 feet operate. A trouble indication is automatically displayed by (9.1 meters)may be used as a guide. Other spacing may be used flashing the LED every second. This meets NFPA 72 field depending on ceiling height,high air movement,and other sensitivity testing requirements. An internal 85 dB horn conditions or response requirements. (available in"S" models)emits a temporal 3 when the detector alarms and a steady tone when power polarity is t reversed. 1.85"(470 cm( 6.1"(15.5 cm( � � e O Product Data Sensitivity.................................................3.1 - 1.0%/ft. (max.) -CST..........................................................................40mA 3.1 +0.50%/ft. (min) -CSRT, CSRH, CSTE................................................51 mA Operating temp. range ............... 32°F to 120°F(0°C to 50°C) Typical avg. polarity reverse current Operating humidity range....................................0 to 95% RH -CST, CSRT, CSTE, and CSRH................................10mA Minimum voltage-C, CT, CRT, CST, CSRT, CSRH , Sounder specifications.........................................85 dB at 10' -CSTE.........................................................................8.5V Heat detector specifications -AT..............................................................................5.1V -fixed temperature ..................................... 135°F(57.2°C) Maximum voltage-C, CT, CRT, CST, CSRT, CSRH, -rate of rise .... 15°F/min. &>105°F(8.3°C/min. &>40.6°C) -CSTE...........................................................................33V Auxiliary relay contacts 2A @ 28 VDC or 120 VAC (resistive) -AT................................................................................27V Alarm contacts ........................ 500 mA @ 36 VDC(resistive) Maximum ripple(peak to peak)........................................ 10% Field wiring size.................................................. 14-24 AWG Typical average standby current.....................................70,A Packaging .......................10 detectors are packed in a carton -CSTE........................................................................23mA Color....................................................white cover/white base Typical alarm current-C, CT and AT ............................15mA with UV inhibitor to prevent yellowing -CRT..........................................................................31 mA Listing UL 268, ULC FM, CSFM and MEA Selection Guide Designator Feature Description H Isolated Fixed Temp. Isolated fixed 135°F(57°C)and rate of rise heat detector,independently trips the LED and alarm and Rate of Rise output.Smoke detector activates internal sounder(local alarm)and auxiliary relay,but Heat Detector does not latch.Approved as both single station smoke alarm and system heat detector. Ideal for hotel,motel and dormitory rooms where smoking is allowed. R Auxiliary Relay Used to activate other devices such as elevator recall,door holders,strobes,etc.Listed for releasing service. S Built-in Sounder 85dB built-in sounder alarms when smoke is detected or when power wiring polarity is reversed. T Intergrated Fixed Intergrated Fixed 135°F(57°C)temperature and rate of rise heat detector. Temp.and Rate of Either heat detector or smoke detector can trip and latch LED and alarm protection. Rise Heat Detector relay outputs. E Built-in end of line Relay is normally energized and will trip with loss of power.Can also provide notification power supervision relay when detector needs maintenance. in t e r I o g i►i•,„ PH 503.692.4052 ©2001 Inte logix,Inc US4 8 Canada: 800.547.2556 Intedogix,(addx,E9,,I fl and Smtrol are trade rks of Technical Service: 800.648.7424 FaxBack:800.483.2495 irnetogix,inc www.sentrd.mm www.intaiogixsawdtyoom E-3965 Rev B-1101 SYSTEM _ �4 SENSOR" � C01 224T Carbon Monoxide Detector with RealTest"Technology The System Sensor CO 7224T CO detector provides early warning by using electrochemical sensing technology to measure carbon monoxide levels in the air. Features With RealTest"technology,the CO gas sensing cell of the •RealTest-technology allows installer to test detector with CO gas C01 224T CO detector can be tested using a carbon monoxide gas agent.Simply hold the test button for two seconds.After the alarm Full compliance with UL 2075 cycle(temp 4)the green LED will flash about once per second, •A code required trouble relay indicating that the detector is ready to accept CO for testing. •Wiring supervision with SEMS terminals Spray a small amount of CO into the detector per the installation instructions,and within seconds the detector will alarm,indicating •A six year end-of-life timer successful gas entry. 12/24 VDC •A current draw of 20mA in standby and 40mA in alarm If dangerous amounts of carbon monoxide is detected,the COI 224T detector will alert residents by sounding and flashing a temp-4 signal Versatile mounting for wall and ceiling alarm.Protection is guaranteed 24/7 by a central station,regardless Electrochemical sensing technology of whether residents are away from home,sleeping or already suffering from the effects of CO. This specific device is designed for system operation.The detector is fully listed to UL 2075.It offers a code required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station.It also uses SEMS-type terminal Philips head screws to provide a quicker and more positive wiring connection and code required wiring supervision.The COI 224T detector offers a low current draw,allowing more devices to be connected to the panel without having to purchase a more expensive panel or an extra power supply. The C01 224T model will operate on most industry security and fire Agency Listings alarm control panels because it is is a 12/24VDC detector. UL LISTED 2075 C01 224T Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide detector shall be a System Sensor model number C01 224T,listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The detector shall be equipped with a sounder and a trouble relay.The detector's base shall be able to mount to a single-gang electrical box or direct (surface)mount to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide dual color LED indication,which blinks to indicate normal standby,alarm,or end-of-life.When the sensor supervision is in a trouble condition,the detector shall send a trouble signal to the panel.When the detector gives a trouble or end-of-life signal,the detector shall be replaced.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA(75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size Length:5.1 in,Width: 3.3 in,Height:1.3 in Approximate Weight 7 oz Operating Temperature Range 32°F to 104°F(0°C to 40°C) Operating Humidity Range 22 to 90%RH Input Terminals 14 to 22 AWG Mounting Single-gang back box;surface mount to wall or ceiling Operation Modes Operation Normal(standby) Blink 1 per minute — — Alarm Blink in temp 4 pattern Sound in temp 4 pattern RealTest'Feature: The System Sensor C01 224T carbon monoxide detector with RealTest"can evaluate the functionality of the CO sensing cell using canned test agent. r L L rZONE Cad?CARBON MONOXIDE I L V Push and hold the Test/Hush button for Spray canned CO agent into the detector. Verify CO sensing at the control panel.The two seconds to enter RealTest mode.The detector will automatically exit RealTest green LED will flash once every second to alarm mode after about 20-60 seconds. indicate RealTest mode has started. NOTE:Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an installation. Hush Feature: Pushing theTest/Hush button will silence the sounder for 5 minutes(except in RealTest mode). Trouble Feature: When the detector is in a trouble condition,it will send a trouble signal to the panel. End-of--life Timer: After the detector's internal sensor has reached the end of its life,a trouble signal will be sent to the panel.This will indicate that it is time to replace the detector.An electrochemical carbon monoxide detector lifespan is approximately six years,and the detector must be replaced by the date marked on the inside of the product. Ordering Information Part No. Description C01 224T 12/24 volt,4-wire system-monitored carbon monoxide detector with RealTest-Technology l`�� 1 SYSTEM 02 change wit Sensor. `` r r/ 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice,Visit rystemsensoccom for SENSOR` Phone:800-SENSOR2•Fax:630-377-6495 urrentproductinformat-0437-000.8/08.estversionofthlsda[asheet. A05-0437-000.8/08•#7953 DF-52121:C•E-325 MMF-300(A) Series, F�f''e•LITerALaf l'Y1S MDF-300(A) Addressable Monitor Modules by Honeywell Addressable Devices General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices,such as conventional heat detectors and pull stations, [lip or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). a PT, .'P MMF-300(A)is a standard-sized module(typically mounts to a =L -,., 4" [10.16 cm] square box) that supervises either a Style D A: M (Class A) or Style B (Class B) circuit of dry-contact input 95"`p()„e„ devices. s” -1<._.,..P POPUPO MMF-301(A)is a miniature monitor module a mere 1.3" (3.302 aa, cm)H x 2.75"(6.985 cm)W x 0.5"(1.270 cm) D used to super—"e°; III �II vise a Style B(Class B)circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D(Class A) or Style B(Class B)circuit. MDF-300(A)is a standard-sized dual monitor module used to MMF-300(A)(Type H) monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two may be wired as an NFPA Style B(Class B) or Style D (Class separate,consecutive addresses in intelligent,two-wire systems. A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor LiteSpeedTM is a communication protocol developed by (provided) terminates the Style B circuit. No resistor is Fire-Lite Engineering that greatly enhances the speed of com- required for supervision of the Style D circuit. munication between analog intelligent devices. Intelligent MMF-300(A) OPERATION devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU Each MMF-300(A) uses one of the available module stops the group poll and concentrates on single points. The addresses on an SLC loop. It responds to regular polls from net effect is response speed greater than five times that of the control panel and reports its type and the status(open/nor- other designs. designs. mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control MMF-300(A) Monitor Module panel. The LED latches steady on alarm (subject to current limitations on the loop). • Built-in type identification automatically identifies this device as a monitor module to the control panel. MMF-300(A) SPECIFICATIONS • Powered directly by two-wire SLC loop. No additional power Nominal operating voltage: 15 to 32 VDC. required. Maximum current draw:5.0 mA(LED on). • High noise(EMF/RFI) immunity. Average operating current: 350 pA (LED flashing), 1 com- • SEMS screws with clamping plates for ease of wiring. munication every 5 seconds,47k EOL. • Direct-dial entry of address: 01 —159 on MS-9600 series Maximum IDC wiring resistance:40 ohms. panels,01 —99 on other compatible systems. LED flashes during normal operation and latches on steady EOL resistance:47K ohms. • to indicate alarm. Temperature range: 32°F to 120°F(0°C to 49 0C). The MMF-300(A) Monitor Module is intended for use in intelli- Humidity range: 10%to 93%noncondensing. gent, two-wire systems, where the individual address of each Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x module is selected using the built-in rotary switches. It pro- 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x vides either a two-wire or four-wire fault-tolerant Initiating 2.125" (5.398 cm)deep box. Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A)APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit DF-52121:C•10/06/2010—Page 1 of 4 MMF-301(A) Mini Monitor Module Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x • Built-in type identification automatically identifies this device 0.65"(1.651 cm)deep. as a monitor module to the panel. Wire length:6" (15.24 cm) minimum. • Powered directly by two-wire SLC loop. No additional power required. MMF-302(A) Interface Module • High noise(EMF/RFI) immunity. • Supports compatible two-wire smoke detectors. • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct-dial entry of address: 01 – 159 on MS-9600 series source. panels,01 –99 on other compatible systems • High noise(EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. 3 1415 0 1 ADDRESS 0 1 • Direct-dial entry of address: 01 – 159 on MS-9600 series 13 �� 2 2 panels,01 –99 on other compatible systems. 3 12 3 LOOP O )3 • LED flashes during normal operation. 11 4 L-1 /4 • LED latches steady to indicate alarm on command from control panel. 10 9 TENSE 5 BONES 6 5 The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status(nor- mal, open, or alarm)of one full zone of conventional detectors Lu Q back to the control panel. All two-wire detectors being moni- UJ m tored must be UL compatible with the module. The MMF- 302(A) can be used to replace M302(A) modules in existing systems. MMF-302(A)APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke The MMF-301(A) Mini Monitor Module can be installed in a detectors. The monitored circuit may be wired as an NFPA single-gang junction directly behind the monitored unit. Its Style B(Class B)or Style D (Class A) Initiating Device Circuit. small size and light weight allow it to be installed without rigid A 3.9 K ohm End-of-Line Resistor (provided) terminates the mounting. The MMF-301(A) is intended for use in intelligent, end of the Style B or D (class B or A) circuit (maximum IDC two-wire systems where the individual address of each module loop resistance is 25 ohms). Install ELR across terminals 8 is selected using rotary switches. It provides a two-wire initiat- and 9 for Style D application. ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301(A) modules in MMF-302(A)OPERATION existing systems. Each MMF-302(A) uses one of the available module MMF-301(A)APPLICATIONS addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/nor- Use to monitor a single device or a zone of four-wire smoke mal/short) of its Initiating Device Circuit (IDC). A flashing LED detectors,manual fire alarm pull stations,waterflow devices,or indicates that the module is in communication with the control other normally-open dry-contact devices. May also be used to panel. The LED latches steady on alarm (subject to current monitor normally-open supervisory devices with special super- limitations on the loop). visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B(Class B) Initiating Device Circuit. MMF-302(A)SPECIFICATIONS A 47K ohm End-of-Line Resistor(provided)terminates the cir- Nominal operating voltage: 15 to 32 VDC. cult. Maximum current draw:5.1 mA(LED on). MMF-301(A)OPERATION Maximum IDC wiring resistance:25 ohms. Each MMF-301(A) uses one of the available module Average operating current: 300 pA, 1 communication and 1 addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol. the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC). EOL resistance:3.9K ohms. MMF-301(A) SPECIFICATIONS External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms Nominal operating voltage: 15 to 32 VDC. maximum. Current: 90 mA per module maximum. Average operating current: 350 NA, 1 communication every Temperature range: 32°F to 120°F(0°C to 49°C). 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Humidity range: 10%to 93%noncondensing. Maximum IDC wiring resistance:40 ohms. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Maximum IDC Voltage: 11 Volts. 2.125' (5.398 cm)deep box. Maximum IDC Current:400 pA. EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DF-52121:C•10/06/2010 MDF.300(A) Dual Monitor Module Product Line Information The MDF-300(A) Dual Monitor Module is intended for use in NOTE:"A"suffix indicates ULC-listed model. intelligent, two-wire systems. It provides two independent two- MMF-300(A): Monitor module. wire initiating device circuits(IDCs)at two separate,consecutive addresses. It is capable of monitoring normally open contact fire MMF-301(A): Monitor module, miniature. alarm and supervisory devices.The module has a single panel- MMF-302(A): Monitor module,two-wire detectors. controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- MDF-300(A): Monitor module, dual, two independent Class B cuits ONLY. Style D (Class A) IDC circuits are NOT supported in circuits. any application. SMB500:Optional surface-mount backbox. MDF-300(A)SPECIFICATIONS NOTE: See installation instructions and refer to the SLC Wiring Normal operating voltage range: 15 to 32 VDC. Manual, PN 51309. Maximum current draw:6.4 mA(LED on). Architects'/Engineers' Specifications Average operating current: 750 pA(LED flashing). Specifications of these devices and all FireLite products are Maximum IDC wiring resistance: 1,500 ohms. available from FireLite. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:240 pA EOL resistance:47K ohms. Maximum SLC Wiring resistance:40 Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm)deep. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only.Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm)square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A)module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes,ordinances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S2424 • ULC: S2424 • FM Approved • CSFM: 7300-0075:0185 • MEA:72-01-E DF-52121:C•10/06/2010—Page 3 of 4 Fire•Lite®and LiteSpeed®are registered trademarks and FireWatchTM is a trademark of Honeywell International Inc. 02010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING R MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 4 of 4—DF-52121:C•10/06/2010 DF-52347:A•E-900 MMF-300.10(A) FirellTeALarmS Ten-Input Monitor Module by Honeywell Addressable Devices General The MMF-300-10 ten-input monitor module is an interface mm mm m m between a control panel and normally open contact devices � ® ®® ®® in intelligent alarm systems such as pull stations, security contacts,or flow switches. The first address on the MMF-300-10 is set from 01 to 150 _ and the remaining modules are automatically assigned to the _ - next nine higher addresses. Provisions are included for dis- abling a maximum of two unused addresses. The supervised state (normal, open, or short) of the moni- tored device is sent back to the panel. A common SLC input is used for all modules,and the initiating device loops share a common supervisory supply and ground — otherwise each monitor operates independently from the others. 1 Each MMF-300-10 module has panel-controlled green LED indicators. The panel can cause the LEDs to blink, latch on, or latch off. NOTE: Unless otherwise specified,the term MMF-300-10 is used in this data sheet to refer to both the MMF-300-10 and the MMF- 300-10A(ULC-listed version). Features Mounting options: • Listed to UL Standard 864, 9th edition. –CHS-6 chassis: Up to 6 modules. • Ten addressable Class B or five addressable Class A initi- –BB-6F cabinet: Up to 6 modules. ating device circuits. –BB-2F cabinet: One or two modules. • Removable 12 AWG (3.25 mm2) to 18 AWG (0.9 mm2) Wire gauge: 12 AWG (3.25 mm2)to 18 AWG (0.9 mm2). plug-in terminal blocks. Power-limited circuits must employ type FPL, FPLR, or P Y Yp • Status indicators for each point. FPLP cable as required by Article 760 of the NEC. • Unused addresses may be disabled. MMF-300-10 is shipped in Class B position; remove shunt • Rotary address switches. for Class A operation. • Class A or Class B operation. Maximum SLC wiring resistance: 40 or 50 ohms, panel • Flexible mounting options. dependent. • Mounting hardware included. Maximum IDC wiring resistance: 1500 ohms. Specifications Maximum IDC voltage: 10.2 VDC. Standby current: 3.5 mA (SLC current draw with all Maximum IDC current: 240 pA. addresses used; if some addresses are disabled, the standby current decreases). Alarm current: 55 mA(assumes all ten LEDs solid ON). Temperature range: 32°F to 120°F (0°C to 49°C) for UL applications;–10°C to+55°C for EN54 applications. Humidity: 10% to 85% noncondensing for UL applications; 10%to 93%noncondensing for EN54 applications. Dimensions: 6.8" (172.72 mm) high x 5.8" (147.32 mm) wide x 1.25' (31.75 mm)deep. Shipping weight: 0.76 lb. (0.345 kg) including packaging. DF-52347:A•05/15/2009—Page 1 of 2 Agency Listings and Approvals The listings and approvals below apply to the MMF-300- 10(A)Ten-Input Monitor Module. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. • UL Listed: S2424 • ULC Listed: S2424 • CSFM approved:7300-0075:205 • FM approved • MEA approved:55-02-E Product Line Information MMF-300-10:Ten-input monitor module. MMF-300-10A: Same as above with ULC Listing. BB-2F: Optional cabinet for one or two modules. Dimen- sions, DOOR: 9.234" (23.454 cm) wide (9.484" [24.089 cm] including hinges), x 12.218" (31.0337 cm) high, x 0.672" (1.7068 cm) deep; BACKBOX: 9.0" (22.860 cm) wide (9.25" [23.495 cm] including hinges), x 12.0" (30.480 cm) high x 2.75" (6.985 cm); CHASSIS (installed): 7.150" (18.161 cm) wide overall x 7.312" (18.5725 cm) high interior overall x 2.156" (5.4762 cm)deep overall. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis (below). Dimensions, DOOR: 24.0" (60.96 cm) wide x 12.632" (32.0852 cm) high, x 1.25' (3.175 cm) deep, hinged at bottom; BACKBOX: 24.0" (60.96 cm)wide x 12.550" (31.877 cm) high x 5.218" (13.2537 cm)deep. CHS-6: Chassis, mounts up to six modules in BB-6F. FireLite@ Alarms@ and System Sensor@ are registered trademarks of Honeywell International Inc. Microsoft@ and Windows@ are registered trademarks of the Microsoft Corporation. 02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Made in the U.S.A. www.firelite.com Page 2 of 2—DF-52347:A•05/15/2009