HomeMy WebLinkAboutDRB130317
Project Name:NIELDS REROOF/SOLAR DRB Number: DRB130317
Project Description:
INSTALLATION OF 6.25 KWH PV SOLAR SYSTEM. REMOVAL/RELOCATION OF EXSITING SOLAR
THERMAL SYSTEM. REMOVAL OF EXISTING CEDAR SHAKES AND INSTALL NEW SYNTHETIC
ROOFING SYSTEM.
Participants:
OWNER NIELDS, MORGAN W. & BELINDA 07/30/2013
4 SUNRISE DR
ENGLEWOOD, CO
80110
APPLICANT NIELDS, MORGAN W. & BELINDA 07/30/2013
4 SUNRISE DR
ENGLEWOOD, CO
80110
Project Address:767 POTATO PATCH DR VAILLocation:
ELK CREEK TOWNHOMES UNIT 3
Legal Description:Lot: Block: Subdivision: ELK CREEK TOWNHOMES
Parcel Number:2101-063-2000-3
Comments:See Conditions
BOARD/STAFF ACTION
Motion By: Action: STAFFAPP
Second By:
Vote: Date of Approval: 08/15/2013
Conditions:
Cond: 8
(PLAN): No changes to these plans may be made without the written consent of Town of
Vail staff and/or the appropriate review committee(s).
Cond: 0
(PLAN): DRB approval does not constitute a permit for building. Please consult with
Town of Vail Building personnel prior to construction activities.
Cond: 201
(PLAN): DRB approval shall not become valid for 20 days following the date of
approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS.
Cond: 202
(PLAN): Approval of this project shall lapse and become void one (1) year following
the date of final approval, unless a building permit is issued and construction is
commenced and is diligently pursued toward completion.
Cond: CON0013361
Solar energy device framing, brackets and associated equipment shall be black or a
color that matches adjacent building surfaces.
Planner:Joe Batcheller DRB Fee Paid: $20.00
********************************************************************************************
TOWN OF VAIL, COLORADOCopy Reprinted on 07-30-2013 at 08:31:31 07/30/2013
Statement
********************************************************************************************
Statement Number: R130001086 Amount: $20.00 07/30/201308: 31 AM
Payment Method: Check Init: DR
Notation: CK# 3645 ERIC
JOHNSON ARCHITECT
-----------------------------------------------------------------------------
Permit No: DRB130317 Type: DRB-Minor Alt,SFR/DUP
Parcel No: 2101-063-2000-3
Site Address: 767 POTATO PATCH DR VAIL
Location: ELK CREEK TOWNHOMES UNIT 3
Total Fees: $20.00
This Payment: $20.00 Total ALL Pmts: $20.00
Balance: $0.00
********************************************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------
------------
DR 00100003112200 DESIGN REVIEW FEES 20.00
-----------------------------------------------------------------------------
D Q V IE Department of Community Development
75 South Frontage Road
TOWN OF nVAL Vail, CO 81657
JUL 2 9 2013 Tel: 970-479-2128
www.vailgov.com
Development Review Coordinator
Appli R 4 view
Minor Exterior Alteration
General Information: This application is required for all proposals involving minor changes to buildings and site
improvements, such as roofing, painting, window additions, landscaping, fences, retaining walls, etc. Applicable Vail
Town Code sections can be found at www.vailgov.com under Vail Information -Town Code Online. All projects requiring
design review must receive approval prior to submitting a building permit application. An application for Design Review
cannot be accepted until all required information is received by the Community Development Department, as outlined in
the submittal requirements. The project may also need to be reviewed by the Town Council and/or the Planning and
Environmental Commission. Design review approval expires one year from the date of approval, unless a building permit
is issued and construction commences.
Fee: $250 for Multi-Family/Commercial
$20 for Single Family/Duplex
_`Single Family Duplex Multi-Family Commercial
Description of the Re est: � �� 1� (O ` 2 w ' `� ��- ,
• �o��l �2cc �L� SG► �( � `
d
Physical Address: z->b ��k- CV-4W_ 7ow i,. k orki ,:=.
Parcel Number: 0(o-92 20 003 (Contact Eagle Co. Assessor at 970-328-8640 for parcel no.)
• Property Owner: 1&2 S1f&1 N 4,t- L,�7.1'
• Mailing Address: 5� S1un.f(iJF Pit i '-�
G L CJ, Iff 9 • Phone: 303 — ; � — �S Fn
* Owner's Signature: l? — C—
Primary Contact/Owner Representative:
Mailing Address: \ice
Phone: "� 2-�0 �`Z°12
E-Mail: 4Z �U_GtI °10 • Cork, Fax:
For Office Use Only:
Cash_ CC: Visa/ MC Last 4 CC# Exp. Date: Auth # Check# 34P
Fee Paid:11 Received From: Ea, c- qbtdu50)J 4AC14 a ec.T
Meeting Date: 0%1e)q 13 DRB No.: � ►�
Planner: Project No3- O 3CoS
Zoning: Land Use:
Location of the Proposal: Lot: Block:__Subdivision:_ VA{f_ P r4-rn /SAT del
Tn8?Jk
30INT PROPERTY OWNER
WRITTEN APPROVAL LETTER
This form is applicable to all Design Review applicants that share ownership of the subject property. For exam-
ple,the subject property where construction is occurring is a duplex, condominium or multi-tenant building. This
form shall be completed by the applicant's neighbor/joint property owner. In the case of a multiple-family dwell-
ing or multi-tenant building, the authority of the association shall complete this form and mail to: Community
Development Department,75 South Frontage Road,Vail,CO 81657 or fax to 970.479.2452.
IylIC-NF�F_t— ASZi&S
I, (print name) ,a joint owner,or authority of the association,of pr6gerTy
located at 7 4o l Por ATE P-J 7 t ,k iL>Q . provide this letter as
written approval of the plans dated pJoltm a o 2nt7 which have been submitted to the
Town of Vail Community Development Department for the proposed improvements to be completed at the ad-
dress noted above. I understand that the proposed improvements include:
2 -C 1 t rF.mac_ s Oi' &P
7-r} fZ;f_J( c'> icy Aav►�
i di,,5Z2-S[_L_c f)tr- 2 dT yC r_.T-A1 c-._. Eid tyys r e a N 7-71-,S
Td + C.0
L4
(Signature) M1GWv�c. <�t-442LA r (Date)
rr c cc c �-ra wa4c
r'iLS t 0{eJ..Jr
Additlonally,phmm check the statement below which is most applicable to Vow
J I understand that minor modifications may be made to the plans over the course of the review process to en-
sure campA with the Town's applicable codes and regulations.
(In)tial here)
%o I request that all modifications, minor or otherwise, which are made to the plans over the course of the re-
view process, be brought to my attention by the applicant for additional approval before undergoing further re-
6-44 by the Town.
`7
(InrOa/here) lG�� 6-44��s- }�i2 3 t✓.�tr'(--
�?7D-9�� - food
f.\cdev\forms\permhslPianning\DRB\DRB_Conceptual Review_010110
i
• Property Information/
Property Address
Parcel # .L ' D r O6 "2'-Oc O 3
Legal Description (qrlz 75?qu LA V - co J.
Development Site Area sq ft acres lJ buildable sq
ft
Zone District/SDD#
Hazard Zones Snow Avalanche High Severity _Moderate Severity N/A
Sections 12-21 & 14-7
Debris Flow High Flow _Moderate Flow High Avalanche _ N/A
Rockfall High Severity Medium Severity _ N/A
Excessive Slopes _?30% _N/A
Floodplain _100 year floodplain Floodway Wetlands _N/A
Creeks, Streams _Gore Creek _on site adjacent to site N/A
Section 12-14-17 Other tributary: _on site _adjacent to site _N/A
Project Information
Project Description �0 I��. f'V I
Development Standards Allowed Existing Proposed
Gross Residential Floor Area Primary sq ft
(maximum)
Chapter 12-15 Secondary sq ft
EHU sq ft
TOTAL sq ft
• 250 Addition Interior Conversion
Credits:
Setbacks (minimum) Front ft
Section 14-10-4 Side ft
Side ft
Rear ft
Watercourse ft
Site Coverage (maximum)
see definition Section 12-2-2
Building Height(maximum) Sloping ft
see definition Section 12-2-2 Flat ft
Landscaping Softscape sq ft
See definition Section 14-2-1
Section 14-10-8 Hardscape sq ft
TOTAL s ft
Driveway Max Curb-cuts
Sections 14-3-1 & 14-3-2 Max Grade @
centerline
Min Width
Heated drive? Yes No Yes No
Snow Storage%
Parking #Enclosed Spaces
Sections 12-10& 14-5 #Unenclosed
TOTAL
Outdoor Lighting(maximum) #fixtures 7—
Section 14-10-7
PROPOSED MATERIALS
Building Materials Type of Material Color
Roof 'P� U G �,.Lr._-{•V per
Siding
Other Wall Materials
Fascia /
Soffits /
Windows /
Window Trim /
Doors
Door Trim
Hand or Deck Rails
Flues
Flashinga.�—� `
Chimneys
Trash Enclosures l
Greenhouses
Retaining Walls
Exterior Lighting
Other rU �71nPi� j D V1 �2�
Morgan Nields
763 Potato Patch Dr. #3
Vail, CO 81657
Friday, July 26, 2013
r .
C'TIVE
ERCzIE► �
�_�C)Ij_kR. LL('
A chance to help our tomorrow, today!
PO Box 7627
Avon, CO 81620
Phone: (970) 306-4233
Fax: (866) 403-3485
infoC@activeenergies.com
www.activeenergies.com
System Proposal
Option 3—PV+Thermal System Relocate—lower roof
The following quotation is for the design and installation of a roof mounted,grid-tied, photovoltaic(PV) system to
be located on the roof of the Neilds Residence at 763 Potato Patch Dr.#3, in Vail,CO 81657.
System Size: 6.25kW
Estimated Production: 8,325kWh/year(based on PV Watts/not including shading)
Estimated Offset: 99%of provided electrical usage(91%offset with a 12%reduction in output from snow)
System Layout: Panel Arrangement:5 columns of 5 panels oriented in the landscape position,separated
into two sections,on the east facing roof. Thermal system to be moved to the lower
south roof and reconfigured to fit.
Equipment: Panels:25 Phono Solar PS250P-20/U black solar panels @ 250watts(or equivalent)
Inverter: 25 Enphase M-215 micro-inverters
Mounting Equipment:Unirac Solar Mount Racking System with Zilla Mounting Feet
Monitoring:Enphase Envoy Remote Energy Monitoring System
Complete System Cost $24,288
Existing Solar Thermal System Fix $4,300
Holy Cross Rebate* -$9,000
Federal Tax Credit** -$5,876
Net Cost $13,711
II �'
w
Figure 4:Proposed Layout
ACTIVE
P.O.Box 7627,Avon,CO 81620 1 P: 970.306.4233 1 F: 866.403.3485 1 www.activeenergies.com ENE UZ'GIES
SOLA 1:.t. .
ABOUT PHONO SOLAR
Phono Solar Technology Co., Ltd. is one of the world's
leading renewable energy product manufacturers and a well
trusted brand provider. The Phono Solar brand has become
A$
synonymous with high performing, to quality photovoltaic
7
panels that are ideal for use in large scale power plants,
commercial and residential installations.
HIGH PERFORMANCE SOLAR
MODULES
RELIABLY HIGH YIELDS QUALITY ASSURANCE WARRANTIES
High efficiency solar cells together Durability assured in even the • 10-year product warranty*
with high transmission textured glass harshest environments with AMMONIA • 25-year performance warranty*
deliver module efficiency of over 16.0%, CORROSION, SALT MIST CORROSION, • Free module recycling through PV
leading to minimized installation costs and FIRE TEST certifications. Cycle Association membership"
and maximized system output. Certified to withstand increased snow
High output due to excellent and wind toads of up to 5400Pa.
performance in weak-tight conditions. Manufacturing facility certified by ISO
Higher specific yields due to positive 9001, ISO 14001 and OHSAS 18001.
power sorting. Internal quality control with standards
Product quality is assured through the higher than both IEC and UL.
use of branded components.
PV CYCLE
C E CEC V*mw
0—Energy Counal
IN COMPLIANCE WITH OUR WARRANTY TERMS AND CONDITIONS.
IN PV CYCLE MEMBER COUNTRIES ONLY.SEE: WWW.PVCYCLE.COM
System Proposal
Included in your Photovoltaic System Design:
• Design and full installation of functional,code compliant system, including all required equipment and labor
• Full system documentation including permitting, invoices, instructions and warranty information provided
during system installation
• All AC electrical connections,including system interconnection by a Colorado Certified Master Electrician
• All DC electrical work completed by NABCEP certified staff
• All applicable local,county and state taxes
• Permit procurement and payment
• Facilitation of applicable rebate processes
• Remote Monitoring System
• Financing options are available
• References available upon request
• Removal, relocate and lower angle of existing Solar Thermal system to southeast portion of the roof
• Apply black paint to existing Solar Thermal collectors and apply black powder coating to existing Solar
Thermal racking system
h
R
k,
Figure S.Exompk System
ACTIVE
P.O.Box 7627,Avon,CO 81620 P: 970.306.4233 1 F: 866.403.3485 1 www.activeenergies.com ENF.R(-7IES-
SOLAR.,,..
Project Details
Solar Non-Financial Benefits:
A 6.25kW PV system each year(www.solarenergy.org):
• prevents 5.6 tons of coal from being mined
�ii /� ' • prevents 11.3 tons of CO2 from entering the atmosphere
`/ • keeps 7,875 gallons of water from being consumed
�,,, _ • offsets 16,581 miles from being driven
o • is equivalent to planting 38 trees
,\ q • keeps NO and S02 from being released into the environment
v • Knowing that you are taking another step in protecting the environment!
• Help free yourself from the utility company by limiting your exposure to increasing
energy costs. Own your electricity instead of renting it.
In the 2006 Colorado College State of the Rockies Report, researchers estimated that the Vail Valley area can expect
a 57% decrease in April 1 snowpack by 2085! This snowpack is essential for our drinking water and recreational
snow. We all can do our part to stop the global warming trends. You have the power to reduce your electrical usage,
reducing stress on our electrical grid and emitting fewer greenhouse gases.
Thank you again for choosing Active Energies Solar LLC. Our goal is to save you money on your utility bills, while
lessening impacts on our fragile environment. With this in mind,please let us know if there is anyway we can better
serve you.
Best Regards,
J2sovu w6vu�2st
Vice President
Active Energies Solar,LLC
Jason @activeenergies.com
ACTIVE
P.O.Box 7627,Avon,CO 81620 1 P: 970.306.4233 1 F: 866.403.3485 1 www.activeenergies.com E NE` TR(1)IFS
IMF t j
Fit
p_
"
AW
- .
w N
-,mot• � � - � _
�J
I.yam ir -
,� -� -
m
�.
f
Awool
-
- at _
- a -
.. MM
Ima
lTff=D l®,�
_WH G L ttirTloH as L m rT im+-i APPROVED AS NOTED
Town of vniL ,.�
WPM
..... - .. ......_. a �, .
wu.ry.w
ti� P� P��t�v� • � �� �H M tai':
---------'-------------- APPROVED AS MOTED �
FLYr��lN . . _ r I•I,.bv/�tle{J TOWN OF VAfI � .
. r '
I WK
iEter. ��� ��t�' -ro MA4,114�•-� rte. F
i
1
% 1 }
1 '
I � �
1 ;
All
1 �
Design Review Board
ACTION FORM
*V,% Department of Community Development
M Off 75 South Frontage Road, Vail, Colorado 81657
tel: 970.479.2139 fax: 970.479.2452
CCWAN,v0EWL0PWNT web: www.vailgov.com
Project Name: NIELDS SOLAR PANELS DRB Number: DRB090022
Project Description:
TWO SOLAR PANELS LANDSCAPE MODE AT 50 DEGREES FOR HOT WATER
Participants:
OWNER NIELDS, MORGAN W. &BELINDA 01/29/2009
4 SUNRISE DR
ENGLEWOOD
CO 80110
APPLICANT NIELDS, MORGAN W. &BELINDA 01/29/2009
4 SUNRISE DR
ENGLEWOOD
CO 80110
Project Address: 767 POTATO PATCH DR VAIL Location:
UNIT 3, ELK CREEK TOWNHOMES
Legal Description: Lot: Block: Subdivision: ELK CREEK TOWNHOMES
Parcel Number: 2101-063-2000-3
Comments: SEE CONDITIONS
BOARD/STAFF ACTION
Motion By: DUBOIS Action: APPROVED
Second By: GILLETTE
Vote: 4-0-0 Date of Approval: 02/09/2009
Conditions:
Cond: 8
(PLAN): No changes to these plans may be made without the written consent of Town of
Vail staff and/or the appropriate review committee(s).
Cond: 0
(PLAN): DRB approval does not constitute a permit for building. Please consult with
Town of Vail Building personnel prior to construction activities.
Cond: 201
(PLAN): DRB approval shall not become valid for 20 days following the date of
approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS.
Cond: 202
(PLAN): Approval of this project shall lapse and become void one(1) year following
the date of final approval, unless a building permit is issued and construction is
commenced and is diligently pursued toward completion.
Cond: CON0010560
The applicant shall paint the frame, support structure, and the associated pipes,
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
TOWN OF VAII '
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
ADD/ALT SFR BUILD PERMIT Permit #: B09-0045
Project #: PRJ09-0020
Job Address: 767 POTATO PATCH DR VAIL Status. . FINAL
Location......: UNIT 3, ELK CREEK TOWNHOMES Applied . . : 04/01/2009
Parcel No....: 210106320003 Issued . .. : 04/24/2009
Expires . ..: 04/27/2009
OWNER NIELDS, MORGAN W. & BELINDA 04/01/2009
4 SUNRISE DR
ENGLEWOOD
CO 80110
APPLICANT SUNSHINE SOLAR&MECHANICAL 04/01/2009 Phone: 970-547-8090
PO BOX 9992
BRECKENRIDGE
CO 80424
License:416-M
CONTRACTOR SUNSHINE SOLAR&MECHANICAL 04/01/2009 Phone:970-547-8090
PO BOX 9992
BRECKENRIDGE
CO 80424
License:416-M
Description:
NEW MECHANICAL SYSTEM
Occupancy: IRC Valuation: $9,000.00
Type Construction:IRC Total Sq Ft Added: 0
+++#+++++++ll+++++l++l+!l+l++!!!!!!l+l+++++!!!!!++!*!*#*#+!**#**###+****+*#*###!! FEE SUMMARY ++**++++1+++++*+++++!!!+!#!!!!!!!+!!+!!!!l+l+++#!!!!+!!l+++l+!!!!+l++l+!!!+!!!*
Building Permit Fee------> $167.25 Will Cal Fee---------------------> $4.00 Total Calculated Fees-------------> $279.96
Plan Check--------------------> $108.71 Use Tax Fee---------------------> $0.00 Additional Fees-----------------------> $3.75
Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES--------------> $283.71
Investigation-----------------> $0.00 Recreation Fee-----------------> $0.00
Payments-------------------------------> $283.71
Total Calculated Fees--------> $279.96 BALANCE DUE------------------------> $0.00
DECLARATIONS
I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
8:00 AM -4:00 PM.
Signature of Owner or Contractor Date
Print Name
I
bld_alt_construction_permit_041908
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MWiYOF VAfI
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149
MECHANICAL PERMIT Permit #: M09-0011
AMF Project #: PRJ09-0020
Job Address: 767 POTATO PATCH DR VAIL Status . . . : FINAL
Location.....: UNIT 3, ELK CREEK TOWNHOMES Applied . . : 01/26/2009
Parcel No...: 210106320003 Issued . . . 01/26/2009
Expires . .: 04/28/2009
OWNER NIELDS, MORGAN W. &BELINDA 01/26/2009
4 SUNRISE DR
ENGLEWOOD
CO 80110
APPLICANT SUNSHINE SOLAR&MECHANICAL 01/26/2009 Phone: 970-547-8090
PO BOX 9992
BRECKENRIDGE
CO 80424
License:416-M
CONTRACTOR SUNSHINE SOLAR&MECHANICAL 01/26/2009 Phone: 970-547-8090
PO BOX 9992
BRECKENRIDGE
CO 80424
License:416-M
Desciption: NEW MECHANICAL SYSTEM: INSTALL BOILER, HOT WATER STORAGE
TANK
Valuation: $21,000.00
+##+++++++++++++++++*«#####*##*#**########+##««***##*##**#***#*####+++++#+++++*+FEE SUMMARY+#++++###+##***********+++#+#++++++#+*#*####***##**#*##+#«+++«#*+#####****###+####++#
Mechanical Permit Fee---> $420.00 Will Call------------> $4.00 Total Calculated Fees---> $749.00
Plan Check-------------------> $105.00 Use Tax Fee------> $220.00 Additional Fees-----------> $0.00
Investigation-----------------> $0.00 TOTAL PERMIT FEE---> $749.00
Total Calculated Fees--> $749.00 Payments-----------------> $749.00
BALANCE DUE---------> $0.00
APPROVALS
Item: 05100 BUILDING DEPARTMENT
01/26/2009 JLE Action:AP OK TO APPROVE PER CHIRS GUNION
****++*+*+#+#++++++#++++++*+**#*#*******##++++++++++++++++++*#***+*********###+#+##+#+++++++++###*##**##**#########+#+###*####****#**##+######++++***#######*#**#*######++++###########**
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond:22
(BLDG 2003): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND
SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL.
Cond:23
(BLDG 2003): BOILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS
AND CHAPTER 10 OF THE 2003 IMC.
Cond: 25
(BLDG 2003): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003
IFGC.
Cond:29
(BLDG 2003):ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE
2003 IMC AND CHAPTER 3 OF THE 2003 IFGC.,
Cond: 31
(BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS
LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING.
Cond: 32
(BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR
TO AN INSPECTION REQUEST.
Cond: 30
(BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED
MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6.
mechcanical_permit_041908