HomeMy WebLinkAboutA13-0046 DATA SHEETS Honeywell VISTA-32FB COMMERCIAL PARTITIONED FIRE AND �`'� '" .�;,�'.t�; �. .. , BURGLARY ALARM CONTROL PANEL . . �i� _�•:�-� ;,. C� , � _ � �, � �, -- ,� � . � � � ` _ '� �. �.1 t;_ ,�, Now UL864 9th Edition Approved Designed to integrate seamlessly with CCTV, access control initiating devices, notification circuits, communication devices, and Honeywell's full range of fire and burglary components, keypads, RF receivers and relays are also supported. the new VISTA-32FB provides the ultimate protection of life The VISTA-32FB has been designed to mount quickly and property. The UL Listed commercial fire and burglary and easily. control panel supports up to two partitions and up to 32 zones/points using hardwired, wireless and V-Plex� addressable technologies. A diverse line of Honeywell FEATURES • Supports addressable V-Plex access • Automatic smoke detector sensitivity • False alarm reduction features: control points using VistaKey maintenance testing -Exit error logic (One to Four doors) -Exit delay reset • Commercial Wireless Fire and • Supports eight hardwired zones, Burglary -Cross zoning -Call waiting defeat 24 V-Plex addressable points/zones, . Notification Appliance Circuits (two): -Recent close report or 32 wireless points/zones -Programmable • Can control two separate areas - Individually silenceable • Supports commercial hardwired, addressable V-Plex polling loop (partitions) independently . Carbon monoxide (CO)zone support and wireless zones • Stores up to 512 events and can (Rev 5 and higher) accommodate 75 user codes • Listed to UL864 9th Edition (Rev 5 • Programmable on-board auxiliary and higher) • Easily programmed and maintained relay with newly upgraded Compass Downloader Software VISTA-32FB Honeywell COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES • Hardwired zones —Two-wire smoke detector • Up to four doors using VistaKey —Provides nine style B hardwired zone/group expansion module V-Plex Access Control zones adds two or four zones • Stored events for one call retrieval —EOLR supervised for Fire and UL —Eight zone—Class A and B • Communication burglary installations extender module —Panel operation during download —Supports N.O. or N.C. sensors —Eight zone—Class B extender _Split/Dual Reporting — Individually assignable to one of module eight partitions —One zone supervised contact Applications —Up to 16 two-wire smoke detectors monitor module The VISTA-32FB control is well suited for a variety of applications as an each on zone one and two(32 total) • UL Listed wireless expansion integrated fire and burglary control. • Patented addressable V-Plex ollin —Supports up to 32 wireless zones/ Some of the a lications su p g pp pported are: points using 5881 ENHC or loop technology medical and professional buildings, 5883H Receiver —Supports up to 24 two-wire V-Plex churches or synagogues, office zones/points —Supervised by control for buildings, schools, strip malls, —Global polling technology for check-in signals residences and factory or warehouse faster processing —Tamper protection for transmitters environments. —Supervised by panel — Individually assignable up to Installation — Individually assignable to partitions, eight partitions The VISTA-32FB alarm system has notification circuit (bell) output or —Supports wireless smoke detectors been designed to mount both quickly and easily. It meets all applicable aux relay • Event reporting requirements for UL commercial fire —4,000 ft. capability without the use . Local printer for access or and burglary installations. of shielded cable VISTA related event — Extender/Isolation bus modules Honeywell SPECIFICATIONS Electrical Main Dialer Agency Listings • Primary power: 18VAC @ 72VA • Line seize: Double Pole • FCC Part 15, Class B; FCC Part 68 ADEMCO No. 1451 . Ringer equiv.: 0.7B • UL864/NFPA 72, Central Station and • Quiescent current draw: 300mA . Formats: ADEMCO Low Speed, Remote Station (Fire) • Backup battery: ADEMCO 4+2 Express, ADEMCO • UL609 Local Mercantile - 12VDC, 7AH min to 34.4AH max High Speed, ADEMCO Contact ID, Premises/Mercantile Safe&Vault -Lead acid battery(gel type) Sescoa and Radionics . UL365 police station connected •Alarm power: 12VDC, 1.7A max for Cabinet dimensions burglar alarm each notification (bell) circuit output . 14.5" H X 12.5" W X 3" D • UL610 Central Station •Aux. standby pwr: 12VDC, 1 A max Burglar Alarm Environmental •Total power: 2.3A at 12VDC, . Storage temp: 14° F to 158° F • California State Fire Marshal 3.4A at 24VDC from all sources (-10° C to 70° C) • FM • 24 hours with 1A standby load . Operating temp: 32° F to 122° F • CAN/ULC S304-Central and Fusing (0° C to 50° C) Monitoring Station Burglar Alarm Unit • Battery input, aux. and notification • Humidity: 85% RH • CAN/ULC S527-Central Unit for (bell) circuit outputs are protected . EMI: Meets or exceeds the Fire Alarm Systems using PTC circuit protectors. All following requirements: • CAN/ULC S303- Local Burglar outputs are power limited. - FCC Part 15, Class B Device Alarm Unit - FCC Part 68 • CAN/ULC S525-Audible Signal - IEC EMC Directive Appliances VISTA-32FB COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL COMPATIBLE DEVICES Auxiliary Devices • 4190WH AlarmNet Communicators • 4204-Relay Module, • 4193SN Two Zone Serial • 7545i-ENT- Internet/Intranet four form C contacts Interface Module Communicator • 4204CF-Two supervised • 4208U Loop Expansion Module • 7845GSM-Digital Cellular output circuits -eight zones Communicator • 5140DLM-Supervised Dialer • 4208SNF Eight Zone/2 Class A/6 • 7845i-GSM-Internet and Digital • 5881 ENHC-RF Receiver Class B Expander Module Cellular Communicator • 5883H-RF Receiver • 4293SN One Zone Serial • 6160CR-2- Red Alpha Keypad Interface Module Access Control •VistaKey V-Plex(addressable) • 6160- Burglary Keypad • 4297 Isolator/Extender Module Access Control • 6220S-System printer used with •V-Plex VSI Isolator Module .VistaKey-SK Starter Kit 4100SM serial module V-Plex Smoke Detectors •VistaKey-EX Expansion Kit Two-Wire Smoke Detectors • 5193SD Commercial Wireless Devices Conventional • 5193SDT • 5808W3-Photoelectronic • System Sensor V-Plex Passive Infrared Detectors Smoke/Heat Detector • ESL . gggMX • 5806W3-Photoelectric Smoke • DSC • IS2500SN Detector Horn/Strobes • DT7500SN • 5809-Wireless Heat Detector • System Sensor • QUEST2260SN • 5817CB-Wireless •Wheelock Commercial Transmitter V-Plex Contacts • Gentex • 4194WH • 5869- Hold-Up Transmitter Manual Pull Stations • 4939SN-WH • 5881 ENHC-RF Receiver • 5140MPS-1 • 4944SN-WH • 5883H-RF Receiver • 5140MPS-2 • 4959SN V-Plex(Addressable) Devices V-Plex Glassbreak Detectors • 4101 SN Relay Zone Module • FG1625SN • 4190SN Remote Point Module -two zones Product specifications subject to change. ORDERING VISTA-32FB Commercial Fire and Partitioned Burglary Alarm Platform V32FB-9 UL864 Rev 9 Version (Rev 5 and higher) Automation and Control Solutions Honeywell Security&Communications Honeywe" 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 wisTS2FBi� October2010 www.honeywell.com oO 20�o Honeywell�nternationa�Inc. ���:�:GFI��IF't�IEC;:�::�:�+:,�: = FEHC�',' T��i i��:f°1 6160 �- ALPHA DISPLAY KEYPAD �4 — ��*.r:�ISRR�IE����* i -i = ��AU4' T� ��`M i WITH DOOR ATTACHED ..,,�� .�.. f „ z m 3 ,:. ��_ .� a w s - i s,w. .�r. �,-., a 9.� � .,:;. a x WITHOUT DOOR The 6160 Deluxe Keypad is easy to install and simple to The oversized function keys are easily accessed even when use. The attractive white console blends with any decor and the keypad door is closed, and can be programmed for fire, features a contoured, removable door that conceals burglary, personal emergencies and other operations. Colored illuminated soft-touch keys. The 6160 also features a new self-adhesive labels are included. larger and brighter 32-character display with easy-to-read plain-English status messages. FEATURES • Large, easy-to-use keypad • Zones and system events displayed • System functions clearly labeled • Keys continuously backlit for greater in plain English • Functions performed by just entering visibility • No confusing blinking lights security code plus command • Speaker with audible beeps • Four programmable function keys • White with removable door blends to indicate: with any decor - System status - Entry/exit delay - Other alarm situations SPECIFICATIONS Physical Wiring Compatibility • 5-5/16"H x 7-3/8"W x 1-3/16"D • - (Black): Ground • Fully compatible with all (135mm x 190mm x 30mm) . + (Red): +12 VDC (Aux. Power) VISTA controls. Current • D1 (Green): "Data in"to control panel • Standby-40mA • DO (Yellow):"Data out"from •Activated Transmission-160mA control panel ORDERING 6160 Alpha Display Keypad Honeywell Security&Custom Electronics �������' Honeywell International Inc. PO Box 9035 cooso,o Syosset, NY 11791 U6160/D September 2006 www.honeywell.com o 2oos HoneyWeu inter�at�o�ai i��. •i, L V L P R 0 D U C T I N F 0 R M A T I 0 N B U L L E T I N � � .;.; . . 449 / 448 SERIES ,;;.,.:. ,. � f �f��' _ � �� Self-Diagnostic, Four- ��:f, _ . � � � R�� ` � Wire, Photoelectric ���i�: _ � ,� �{� .�:-v �� ,f,�,:�r f,���.�� Smoke Detectors fas: _ Model numbers: 449AT,449C,449CT,449CRT,449CST,449CSTE, � , 449CSRT,449CSRH,449CTE -•. -Y., � _.:.��;: :. �.�_.. : o L F M U LC :� � LISTED APPROVED _;f � .r - -;;•r,��=r-� California State Fire Marshal Approved MEA(New York City)Approved ULC model numbers: 448AT,448C,448CT,448CST,448CSRH,448CTE • Intelligent, self-diagnostics The ESL 449/448 Series self-diagnostic, four-wire smoke detectors continually monitor their own • On-site maintenance alert sensitivity and operational status, and provide a visual trouble indication if they drift out of sensitivity • Field replaceable optical chamber range orfail internal diagnostics. This unique, • Low-p rof i l e d esi g n patented technology meets N FPA 72 field sensitivity testing requirements without the need for external • Plug-in terminal block meters. Additional diagnostic information is activated by • Advanced false alarm immunity applying a magnet near the detector's integral reed switch. This initiates a self-diagnostic routine and provides visual indication of sensitivity level, or if service is required. This series is easily cleaned by simply replacing ESL's proprietary field-replaceable optical chamber. All models are designed to reduce false alarms from dust, insects, RFI, and external light. An integral combination rate-of-rise and fixed 135°F (57°C), 50-foot rated, heat sensor is available with all "T" model detectors (see selection guide), allowing latching of the alarm for either smoke or heat. The 449CSRH includes an isolated alarm output for heat and activates an internal non-latching sounder (local alarm) for smoke, making it ideal for motel/hotel and dormitory rooms where smoking is permitted. continued ESL 449 Series Sl�noke Detectors Architectural and Engineering Specifications The ESL 449 Series low-profile, self-diagnostic,four-wire The proprietary optical sensing chamber is field replaceable, smoke detectors work on the light scattering principle.A allowing quick and easy cleaning and maintenance. pulsed infrared light-emitting diode serves as the light source, Models with auxiliary relays are approved for releasing and a high-speed photodiode as the sensing element. When service. the amount of light reflected onto the photodiode reaches the This low profile product is equipped with a hinged cover, a sensitivity setting,the smoke sampling rate increases. Three concealed tamper-resistant latch, and insect screens. (3)successive smoke sensings above the sensitivity setting Wiring terminates in plug-in, clamp-type screw terminals. are required to sound an alarm.This design has superior Detectors mount to a standard single-gang electrical box, a protection against false alarms caused by dust, insects, RF four-inch octagonal,four-inch square electrical box, or and ambient-light. WIREMOLD 5739 fixture box. A confirmed alarm causes the normally flashing power Smoke Detector Spacing indicator LED to light continuously and the alarm relay to On smooth ceilings(as defined in NFPA 72),spacing of 30 feet operate. A trouble indication is automatically displayed by (g.1 meters)may be used as a guide. Other spacing may be used flashing the LED every second. This meets NFPA 72 field depending on ceiling height,high air movement,and other sensitivity testing requirements. An internal 85 dB horn conditions or response requirements. (available in"S" models)emits a temporal 3 when the detector alarms and a steady tone when power polarity is t reversed. ,.85•�4���m,� 6.,•�,5.5�m) — � I 1 �—0 — Product Data Sensitivit 3.1 - 1.0%/ft. max. -CST..........................................................................40mA y................................................. ( ) 3.1 +0.50%/ft. (min) -CSRT, CSRH, CSTE................................................51 mA Operating temp. range ............... 32°F to 120°F(0°C to 50°C) Typical avg. polarity reverse current Operating humidity range....................................0 to 95% RH -CST, CSRT, CSTE, and CSRH................................10mA Minimum voltage-C, CT, CRT, CST, CSRT, CSRH , Sounder specifications.........................................85 dB at 10' -CSTE.........................................................................8.5V Heat detector specifications -AT..............................................................................5.1V -fixed temperature ..................................... 135°F(57.2°C) Maximum voltage-C, CT, CRT, CST, CSRT, CSRH, -rate of rise .... 15°F/min. &>105°F(8.3°C/min. &>40.6°C) -CSTE...........................................................................33V Auxiliary relay contacts 2A @ 28 VDC or 120 VAC (resistive) -AT................................................................................27V Alarm contacts ........................ 500 mA @ 36 VDC(resistive) Maximum ripple(peak to peak)........................................ 10% Field wiring size.................................................. 14-24 AWG Typical average standby current.....................................70aA Packaging .......................10 detectors are packed in a carton -CSTE........................................................................23mA Color....................................................white cover/white base Typical alarm current-C, CT and AT ............................ 15mA with UV inhibitor to prevent yellowing -CRT..........................................................................31 mA Listin UL 268, ULC FM, CSFM and MEA g.............................. Selection Guide Designator Feature Description H Isolated Fixed Temp. Isolated fixed 135°F(57°C)and rate of rise heat detector,independently trips the LED and alarm and Rate of Rise output.Smoke detector activates intemal sounder(local alarm)and auxiliary relay,but Heat Detector does not latch.Approved as both single station smoke alarm and system heat detector. Ideal for hotel,motel and dormitory rooms where smoking is allowed. R Auxiliary Relay Used to activate other devices such as elevator recall,door holders,strobes,etc.Listed for releasing service. S Built-in Sounder 85dB built-in sounder alarms when smoke is detected or when power wiring polarity is reversed. T Intergrated Fixed Intergrated Fixed 135°F(57°C)temperature and rate of rise heat detector. Temp.and Rate of Either heat detector or smoke detector can trip and latch LED and alarm protection. Rise Heat Detector relay outputs. E Built-in end of line Relay is normally energized and will trip with loss of power.Can also provide notification power supervision relay when detector needs maintenance. in t e r I o g i►i•.. PH�3.692.�5Z ��,������x.��� US4 8 Canada: 800.547.2556 Irnerlogix,Cadd�c,H,lil and�trol aretraAmiarksof Technical Service: 800.6487424 FaxBack:800.4832495 irnenogix,inc w�vw.sentrd.wrn www.ir�eaiogi�csearity.mm E-3965 Rev B-1101 �� SYSTEM � ��� SENSOR° �` -___.� � , '� BI 5600 Series Mechanical � ` Heat Detectors ��� � � + _� � . _ ...s. � � �, System Sensor's 5600 series mechanical heat detectors '� offer a low-cost means for property protection against ; � � fire, and for non-life-safety installations where smoke �` � ,,� detectors are inappropriate. `__ ?�,������� �':-` - , Features Multiple configurations.The 5600 series offers a full-line of •Multiple configurations for installations configurations to accommodate a broad range of applications.Both —Single-and dual-circuit models single-and dual-circuit models are available for low-and high- —Fixed temp and combination fixed-temp/rate-of-rise temperature ratings with either fixed temperature or combination 135°F or 194°F ratings. fixed temperature/rate-of-rise(ROR)activation.The ROR element of the fixed/ROR models is restorable to accommodate field-testing. •Plain housing for residential installations(Model 5601 P) •Easy-to use terminal screws Installation flexibility.To satisfy a variety of installation needs, •A broad range of back box mounting options: the 5600 series easily mounts to single-gang and octagonal back —Single gang boxes.And these models accommodate four-square back boxes, —3.5""and 4"Octagonal when used with a square to round plaster ring.The reversible —4""square with square to round plaster ring mounting bracket permits both flush-and surface-mount back box installations. •Reversible mounting bracket Visual identification.The 5600 series provides dear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric characters identify the activation method,as well as the temperature rating,in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX,while combination fixed/rate of-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.When the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings � u� F M MEA «(�� a roved ��'°°'° LISTED APPROVED pp s_,oi io,aoce i.�-os-e ;zio-;zo���zz, Specifications Mechanical heat detector shall be a System Sensor 5600 series model number ,listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single circuit or a dual-circuit type,normally open.The detector shall be rated for activation at either 135°F(57°C)or 194°F(90°C),and shall activate by means of a fixed temperature thermal sensor,or a combination fixed temperature/rate-of-rise thermal sensor. The rate of rise element shall be activated by a rapid rise in temperature,approximately 15°F(83°C)per minute.The detector shall indude a reversible mounting bracket for mounting to 3'/z-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterlor of the housing to identify its temperature rating and activation method.The rate of rise element of combination fixed temperature/rate of rise models shall be restorable,to allow for field-testing.The detectors shall indude an external collector that shall drop upon activation to identify the unit in alarm. •. Maximum Installation Temperature 5601 P,5603,5621,and 5623:100°F(38°C) 5602,5604,5622,and 5624:150°F(65.6°Q Operating Humidity Range 5 to 95%RH non-condensing Dimensions with mounting bracket Diameter:4.57 inches(11.6cm) Height: 1.69 inches(43cm) Alarm Temperature 5601 P,5603,5621,and 5623:135°F(57°C) 5602,5604,5622,and 5624:194°F(90°C) Weight 6 oz(170 grams) Rate-of-RiseThreshold 15°F(83°Q rise per minute(models 5601 P,5602,5621,and 5622 only) Mounting 3Yrinch octagonal back box 4 inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring . . Operating Voltage/Contact Ratings 6-125VAC/3A 6-28VDC/1 A 125VDC/03A 250VDC/O.IA InputTerminals 14-22 AWG eoai� xi xi aoaixi O O O O O �4� � � o � � i � i- � 5607P 5602,5622 5603,5623 5604,5624 5621 Ordering Information - - � 5601 P Single None 135°F(57°C) Fixed Temperature/Rate of Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(1524m x 152m) 5603 Single Lettering 135°F(57°Q Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual Lettering 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(1524m x 152m) 5622 Dual Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(1524m x 15Zm) 5623 Dual Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5624 Dual Lettering 194°F(90°Q Fixed Temperature 25 feet x 25 feet(7.62m x 7b2m) *NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. l\��� �\��� �ZOCE �_tc n Sen� �� �� 3825 Ohio Avenue•St.Charles,IL 60174 ��a��rspe<�fi��o�ss�u,��<<o�rz ge �mou�,���<e.u�s��sys�emsenso�-�omro� ��� �����R� PhOIl2:80�-SENS�RZ•FdX:63�-3��-6495 currenrproduainformation,�mdudingthelares[verslonofthlsdatasheet. A05-0351-002•11/06•i31676 �� SYSTEM _ . ,y _ ,_ , _ ��� SENSOR° � ��;:��� � . � * C01224T Carbon Monoxide � �� Detector ,� with RealTestTmTechnology � ,�,;�� i � .�� � � The System Sensor C01224T CO detector provides early - � _� �,,�: �� warning by using electrochemical sensing technology ° -� to measure carbon monoxide levels in the air. Features With RealTest`"technology,the CO gas sensing cell of the •RealTest�"technology allows installer to test detector with CO gas C01224T CO detector can be tested using a carbon monoxide gas agent Simply hold the test button for two seconds.After the alarm •Full compliance with UL 2075 cyde(temp 4)the green LED will flash about once per second, •A code required trouble relay indicating that the detector is ready to accept CO for testing. •Wiring supervision with SEMS terminals Spray a small amount of CO into the detector per the installation instructions,and within seconds the detector will alarm,indicating •A six year end-of-life timer successful gas entry. •12/24 VDC •A current draw of 20mA in standby and 40mA in alarm If dangerous amounts of carbon monoxide is detected,the C01224T detector will alert residents by sounding and flashing a temp-4 signal •Versatile mounting for wall and ceiling alarm.Protection is guaranteed 24/7 by a central station,regardless •Electrochemical sensing technology of whether residents are away from home,sleeping or already suffering from the efFects of C0. This specific device is designed for system operation.The detector is fully listed to UL 2075.It offers a code required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station.It also uses SEMS-type terminal Philips head screws to provide a quicker and more positive wiring connection and code required wiring supervision.The C01224T detector offers a low current draw,allowing more devices to be connected to the panel without having to purchase a more expensive panel or an extra power supply. The C01224T model will operate on most industry security and fire Agency Listings alarm control panels because it is is a 12/24VDC detector. U` LISTED �o�s C01224T Carbon Monoxide Detector Specifications Carbon monoxide detector shall be a System Sensor model number C01224T,listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The detector shall be equipped with a sounder and a trouble relay.The detector's base shall be able to mount to a single-gang electrical box or direct (surface)mount to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide dual color LED indication,which blinks to indicate normal standby,alarm,or end-of-Iife.When the sensor supervision is in a trouble condition,the detector shall send a trouble signal to the panel.When the detector gives a trouble or end-of-life signal,the detector shall be replaced.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA(75 mA test) Alarm Contact Ratings 0.5 A@ 30 VDC Trouble Contact Ratings 0.5 A@ 30 VDC Size Length:5.1 in,Width: 33 in,Height:13 in Approximate Weight 7 oz Operating Temperature Range 32°F to 104°F(0°C to 40°C) Operating Humidity Range 22 to 90%RH InputTerminals 14 to 22 AWG Mounting Single gang back box;surface mount to wall or ceiling Operation Modes .. - � - � Normal(standby) Blink 1 per minute — — Alarm — Blink in temp 4 pattem Sound in temp 4 pattern RealTest""Feature: The System Sensor C01�24T carbon monoxide detector with RealTest` can evaluate the functionality of the CO sensing cell using canned tcst agent. - • • <� '� _ � � \ � i ^ � � �� r � I� � �: � 0 Push and hold theTest/Hush button for Spray canned CO agent Into the detector. Verify CO sensing at the control panel.The two seconds to enter RealTest mode.The detector will automatically exit RealTest green LED will flash once every second to alarm mode after about 20 60 seconds. indicate RealTest mode has started. NOTE:Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an Installation. Hush Feature: Pushing theTest/Hush button will silence the sounder for S minutes(except in RealTest mode). Trouble Feature: When the detector is in a trouble condition,it will send a trouble signal to the panel. End of IifeTimer: After the detector's internal sensor has reached the end of its life,a trouble signal will be sent to the panel.This will indicate that it is time to replace the detector.An electrochemical carbon monoxide detector lifespan is approximately six years,and the detector must be replaced by the date marked on the inside of the product. Ordering Information �- C01224T 12/24 volt,4 wire system monitored carbon monoxide detector with RealTest""Technology �� SYSTEM ozoo8 sy,em sen=o�. w, 3825�h10 f�V2YlUe•St.�{ldY�eS,��6�174 ?roductspe6�ca�onssub�rcttorn gcwithoutnotrce.uis�sysremsensor.comfor �' �l' SE/�/SOR Ph0112:8��-SENS�RZ•FdX:63�-3��-6495 cwren[producUnfom�ation,lndudingehelacestversionofthlsdatasheet. � A05-0437-000•8/OS•H1953 �� SYSTEM _ _ . , , _, � SENSOR° �" � � _-� --- � - - � - Mini-Horns = �� �' � , � �� �- � � � b; ; �� � � �— , �` ."� � The SpectrAlert�Advance series of mini-horn sounders "�� �� � are designed to simplify installations to provide '� ;�� primary and secondary signaling for fire and security � �� -____ _ � applications. . t SPECTR�ert A � V A N C E Features The MHR and MHW mini-horns operate at 12 and 24 volts and are •12 and 24V operation ideal for hotel,motel or residential fire system applications,where a smaller notification device is desired.The mini-horns offer high •High and low volume settings and low volume settings,and temporal or non-temporal tones. The •Temporal and non-temporal tones horns can be mounted to single gang back boxes for aesthetically •Mounts to single gang back box sensitive applications. Synchronization is also provided when using the MDL module. •Compatible with MDL sync module •Mechanically and electrically compatible with PA400 series The MHR and MHW mini-horns can operate between 32 and 120 Mini-Alert°°sounders degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply.They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. Agency Listings U � °� F M MEA �� LISTED APPROVED approved �k 5401 I 3028007 MEA7 07 E i�5�1553:196 SpectrAlert�Advance Mini-Horn Specifications Mini homs shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a single gang back box.Mini horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems.Mini-horns shall operate between 32 and 120 degrees Fahrenheitfrom a regulated DC,orfull-wave rectified,unfiltered power supply.When used with the Syno-Circuit'"Module,l2-volt rated notification appliance circuit outputs shall operate between nine and 175 volts;24 volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Dimensions 4.6""L x 2.9"�N x.45""D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F(0°C to 49°C) Mounting Surface:single gang back box Flush:4`x 4'"BBD deep back box(23/a""deep) InputTerminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DUFWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data . Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16-33 VDC 76-33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Nomtemporal High 72 71 75 74 80 79 4 Non temporal Low 70 69 73 72 78 77 � 8-17.5 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 ZS 4 Non-temporal Low 17 13 �1 19 Ordering Information �- MHR Mini Horn,Red MHW Minl Horn,White �� SYSTEM ��or�svs�zmse�,��. 3825 Ohio Avenue•St.Charles,IL 60174 aroa�aspe<�a�uo�ss�u;��uornxngew�mo���,o�xe.u�s��sys�emsenso�.�omror ��� �����R� PhOIl2:80�-SENS�RZ•FdX:63�-3��-6495 cwrenrproduc[inforination,�mdudingthelaresrverslonofthlsda[azheet. A05-0414-000•1/07•N1743