Loading...
HomeMy WebLinkAboutA13-0047 DATA SHEETS.pdf osc A Tyco International Company i PowerSeries Control Panels v4.5 Features That PowerSeries v4.5 Control Panels: Feature-Rich with Make a Difference: Proven Performance • CO detector support: wireless PowerSeries Control Panels have a proven reputation for providing the value (WS4913)or hardwired (generic) and dependability that security professionals demand.The modular design of the PowerSeries v4.5 Control Panels provides even more value-added features • Updated PowerSeries Keypads including support for CO detectors, an automatic synching feature to reduce (PK and RFK models)support install time and the flexibility of different alarm reporting paths. CO detectors • Updated PowerSeries Wireless Front-Line Protection Public Switched Telephone Network Receiver(RF5132) supports wireless Internet or GPRS/GSM channels. CO detectors Against The Silent Threat (PSTN)� Of Carbon Monoxide Having Internet with GSM/GPRS as back- • Alternate communicator call routing Poisoning up provides complete security with the via GPRS and IP additional benefit of increased recurring Colorless,tasteless, odorless but monthly revenue(RVIR)for dealers. • Automatic Contact ID over GPRS deadly, carbon monoxide(CO) is impossible to detect without a warning Reduce Installation Time • Automatic Sync for alternate device.With the PowerSeries v4.5 with Easy to Program PC-Link communicators Control Panel, either wireless or hardwired CO detectors can be easily The new Automatic Sync feature Standard PowerSeries Features: integrated into the security system. enables T-Link or GS Communicators Installers have the option of using the to communicate automatically using the • Template programming DSC wireless CO detector(WS4913) - format and account number predefined the perfect solution for difficult-to-wire in the panel programming, reducing • Local and remote downloading locations,with its compact design, the risk of programming errors and battery power and wireless capability- on-site install time. Combined with • Programmable Daylight Savings Time or the hardwired CO detector. template programming and end-of-line configuration, quicker more accurate • Automatic CID Flexible, Alternate Alarm installations means more installations per • 2-way audio Communication Methods day with more revenue. • 1 time use code Traditional phone lines are becoming increasingly less common in many • Keypad lockout homes and businesses as more people opt for VoIP(Voice over IP)or cellular • Programmable false alarm reduction phones.The PowerSeries v4.5 Control features including audible exit delay Panel gives customers the option to and fault, quick exit, automatic arm/ combine alarm reporting paths through • disarm, programmable bell delay timer, etc Contact your distributor www.dsc.com ::: E:) sc A Tyco International Company Make PowerSeries v4.5 Control Panel your preferred choice. Available in three different configurations (PC1 616/PC1 832/ PC1864), the PowerSeries v4.5 Control Panel has the scalability, versatility and flexibility to work in small residential to medium-sized commercial installations. Compatibility: Specifications • User Interfaces include LED, Picture Icon LCD or Power Supply..................................16.5 VAC/40 VA @ 50/60 Hz Full Message LCD Current Draw(Panel) 110 mA(Nominal) ........................................ • Wireless Receivers, Devices and Detectors, Auxiliary&Output................................13.75±5%VDC/700 mA including CO Detectors o Bell Output..........................................13.75 t 5%VDC/700 mA • Audio Alarm Verification Operating Environment.........................32°to 120°F(00 to 49°C) • Telephone Interface/Automation Control Relative Humidity........................................................93%(Max.) • High&Low Current Output Expansion Battery Requirement.......................................4 Ah/7Ah/14 AHr • Alternate Communication Options • Hardwired Expansion and Detectors Individual Specification by PowerSeries • Addressable Expansion and Detectors v4.5 Type • Windows'"Software for PC Downloading • Access Control Integration On-Board Zone Hardwired Zones 16(1 x PC5108) 32(3 x PC5108) 64(7 x PC5108) Wireless Zones 32 32 OU 32 J Keypad Zone Support Yes Yes Yes Keypads 8 8 'r 8 On-board PGM PGM 1 =50 mA PGM 1 =50 mA PGM 1,3,4=50 mA Outputs PGM 2=300 mA PGM 2=300 mA PGM 2=300 mA LPGM Expansion 8 x 50 mA(PC5208) 8 x 50 mA(PC5208) 8 x 50 mA(PC5208) 4 x 500 mA(PC5204) 4 x 500 mA(PC5204) 4 x 500 mA(PC5204) Partitions 2 4 8 User Codes 47+Master Codes 71+Master Codes 94+Master Codes Event Buffer 500 Events 500 Events 500 Events a m o o For product information oo m z a •- - - •-• i •• - Product notice. product names mentioned herein may be trade names ••anr registered trademarks of• •. (92011 21 • DSC POWERSERIESTM KEYPADS C4.� , r i r r PK5500 PK5516 PK5501 PK5508 Features Common to all Keypads: RFK5500 RFK5516 RFK5501 RFK5508 Modern,slim-line landscape keypad PowerSeries high-quality, slim-profile keypads use advanced ' Large, backlit keypad buttons plastics technology to achieve a clean, unobtrusive look that ' 5 programmable function keys homeowners welcome and installers will appreciate for their ' Input/Outputterminal can be programmed to operate as a zone input, programmable easy programming and installation.The keypads feature an output or as a low temperature sensor input/output terminal that can be programmed to operate as ► Individual FAP keys a zone input, programmable output or as a low temperature ► Multiple door chime per zone sensor.The keypads also include adjustable backlit keys that ► Adjustable backlight and keypad buzzer address low-light situations and five programmable keys for . Available in black or white bezels simple one-button activation of system functions. PK5500/ ► Wire channel RFK5500 64-zone full-message keypads support eight ► Dual wall-mount and front cover tamper languages, global partition status and full, 32-character ► Easy-to-install mounting hinge programmable phrases. ► Surface or single-gang box mount DSC , Easy To Use To simplify usage,the keypads feature five programmable keys for easy one-button activation of system functions.The default tasks ✓ assigned to the five function keys are stay arming,away arming, door chime,smoke detector reset and quick exit.With the quick exit function there's no need to disarm and rearm the system every time r an occupant leaves the house or lets the dog out,for example. - 4 Ar 4 -0 � Integrated Temperature Sensor 7 , The keypads' integrated temperature sensor can be programmed p t to activate when room temperature dips below 430 F (60 Q and — restores at 47° F (80 Q. Built-in logic prevents the panel from "- cycling in and out of alarm mode during minor temperature fluctuations, helping to reduce false alarms. Flexibility RF versions of the keypads are available.They include all of the same features as their hardwired equivalents and are able to Compatibility support 32 wireless zones and 16 wireless keys without taking The keypads are compatible with all PowerSeries up a wireless zone slot. control panels. Specifications Dimensions......................6 1116' 7116'x 4 x 13116 (154 mm x 113 mm x 20.5 mm) LCD Viewable Area ................3 910"x 15116" (99 mm x 24 mm) Ordering Information: Current Draw ....................125 mA(Max) PK5500 ......................64-Zone Full-Message Keypad RFK5500 .....................Wireless 64-Zone Full-Message Keypad Voltage.........................12 VDC Nominal PK5501 ......................64-Zone LCD Picture ICON Keypad RFK5501 .....................Wireless 64-Zone LCD Picture ICON Keypad o 0 PK5516 ......................16-Zone LED Keypad Operating Environment ............32 to 120 F RFK5516 ..................... Wireless 16-Zone LED Keypad (00 to 49°C) PK5508 ......................8-Zone LED Keypad RFK5508 .....................Wireless 8-Zone LED Keypad Relative Humidity t0 93% y................. a 0 0 0 0 z Distributed by: For product information www.dsc.com Product specifications and availability subject to change without notice.Certain product names mentioned herein may be trade names and/or tilca Fire& registered trademarks of other companies. Security ©2007 2007.02 DSC Addressable P1 1 ' Smoke 1 DSC addressable photoelectric smoke detectors (FSB-210 series)incorporate a low profile design and features that help reduce false alarms and provide f reliable smoke detection. Designed for use with the MAXSYS° PC4020CF commercial fire panel and PowerSeries control panels(Power832°and Power864T")via the PC5100 addressable zone expander, the detectors include automatic drift compensation, self-diagnostics, and easy-maintenance removable chambers. Precise and quick sensitivity testing is easily accomplished with the i handheld test meter(FSD-100).The detectors are Misted for commercial and residential applications. Product ► Automatic drift compensation ► Self-diagnostics ► Easy-maintenance removable smoke chamber Non-contact sensitivity testing with handheld test meter(F S D-10 0) ® Built-in,dual-sensor heat detector(option) ► Scheduled test from control panel (MAXSYS) ► Removable terminals ► Low profile design Locking/Non-locking mounting plate LIL listed for commercial and residential applications Contact your DSC distributor ■ Fire& www.dsc.com 0 a 0' seculity DSC Addressable Photoelectric Smoke 1 False Alarm Reduction DSC is committed to reducing false alarms and has integrated a number of features into its addressable photoelectric smoke y` . detectors to provide reliable detection. One important feature is automatic drift compensation. It provides a constant level of sensitivity performance for long-term,false-alarm-free operation. ; As dust accumulates in the detector, it compensates to maintain the original factory-set sensitivity and thereby minimizes the potential for false alarms. If the detector reaches its limit of compensation, it will indicate a trouble condition well before the sensitivity increases to a level where false alarms will be generated. Compatibility Non-Contact Sensitivity Testing DSC addressable photoelectric smoke detectors are Precise and quick sensitivity testing is easily accomplished with the compatible with the MAXSYS® PC4020CF commercial non-contact handheld test meter(F S D-100). Powered by a standard fire panel and PowerSeries control panels(Power832 and 9 V alkaline battery and small enough to fit inside a shirt pocket,the Power864)via the PC5100 addressable zone expander. test meter holds 500 readings that can be downloaded to any computer.To initiate a reading,a technician simply holds the test meter near a DSC smoke detector and activates the detector's test button. Specifications MECHANICAL Diameter............................5.8"(147 mm) Height ..............................2.077"(52.8 mm) Color................................White Mounting ...........................Surface mount with screws Bracket..............................Twist on/off either locking or non locking ELECTRICAL Maximum Operating Voltage Range. Panel addressable loop voltage Maximum Standby Current .........1.6 mA Maximum Alarm Current: FSB-210(T) ........... 1.8 mA SENSITIVITY Nominal:3.0%+/-0.8%obscuration/ft.(UL) HEATSENSOR Ordering Information: Alarm:Fixed-temperature 135°F(57.2°C) FSB-210B...2-Wire Addressable Photoelectric Smoke Detector without Heat Sensor ENVIRONMENTAL R FSB-21OBT...2-Wire Addressable Photoelectric Smoke Detector with Heat Sensor Operating Environment .............32°to 100°F Accessories (0°to 37.8°C) FSD-100...Handheld Test Meter FSD-101...Broom Handle Adapter for FSD-100 Relative Humidity ...................5 to 95% a` N O O M r O O O O M Z a Distributed by: 0 S C For product information www.dsc.com Product specifications and availability subject to change without notice.Certain product names mentioned herein may be trade names and/or t[jCO Fire& registered trademarks of other companies. Security ©2005 200511 SYSTEM �4 SEJVSOR� 'I 5600 Series Mechanical Heat Detectors 5601P System Sensor's 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. 5UF/51 5621 Features Multiple configurations.The 5600 series offers a full-line of • Multiple configurations for installations: configurations to accommodate a broad range of applications.Both —Single-and dual-circuit models single-and dual-circuit models are available for low-and high- -Fixed temp and combination fixed-temp/rate-of-rise temperature ratings with either fixed temperature or combination 135°F or 194°F ratings. fixed temperature/rate-of-rise(ROR)activation.The ROR element of the fixed/ROR models is restorable to accommodate field-testing. • Plain housing for residential installations(Model 5601 P) • Easy-to-use terminal screws Installation flexibility.To satisfy a variety of installation needs, • Abroad range of back box mounting options: the 5600 series easily mounts to single-gang and octagonal back —Single gang boxes.And these models accommodate four-square back boxes, —3.5-and 4"Octagonal when used with a square to round plaster ring.The reversible —4-square with square to round plaster ring mounting bracket permits both flush-and surface-mount back box installations. • Reversible mounting bracket Visual identification.The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric characters identify the activation method,as well as the temperature rating,in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX,while combination fixed/ rate-of-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.When the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings l9SIM4, U� FM ULC AO: LISTED APPROVED O 52101 3016008 .;50:90 7270-1653:0167 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single-circuit or a dual-circuit type,normally open.The detector shall be rated for activation at either 135oF(57°C)or 194oF(90°C),and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor.The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15oF(8.3°C)per minute.The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method.The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable,to allow for field-testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Maximum Installation Temperature 5601 P,5603,5621,and 5623: 100°F(38°C) 5602,5604,5622,and 5624: 150°F(65.6°C) Operating Humidity Range 5 to 95%RH non-condensing Dimensions with mounting bracket Diameter:4.57 inches(11.6cm) Height: 1.69 inches(4.3cm) Alarm Temperature 5601 P,5603,5621,and 5623: 135°F(57°C) 5602,5604,5622,and 5624: 194°F(90°C) Weight 6 oz.(170 grams) Rate-of-Rise Threshold 15°F(8.3°C)rise per minute(models 5601 P,5602,5621,and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage/Contact 6-125VAC/3A Ratings 6-28VDC/1A 125VDC/0.3A 250VDC/0.1 A Input Terminals 14-22 AWG aaebe x� x� no uxi O O O O O 5601 P 5602,5622 5603, 5623 5604, 5624 5621 Ordering Information Method Identification .. Model Circuit on Exterior Rating Activation Ceiling* 5601P Single None 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5603 Single Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual Lettering 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5622 Dual Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5623 Dual Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5624 Dual Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) "NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2013 System Sensor. Product specifications subject to change without notice.Visit systemsensorcom Phone:800 SENSOR2•Fax:630-377-6495 or current product information,including the latest version of this data sheet. SENSOR' www.systemsensor.com saoss000,•n,s S YST Em �4 SENSOR" C01224T and C01224TR • • • Carbon Monoxide Detectors with RealTest°Technology The System Sensor CO1224T and CO1224TR(round) Carbon Monoxide(CO)Detectors use a highly accurate and reliable electrochemical sensing cell to provide early warning of dangerous CO levels. Features With RealTest®technology,the CO gas sensing cell used in • RealTest®enables a functional test using canned CO the C01224T and C01224TR CO detectors can be tested using a CO gas agent,fully meeting the requirements of NFPA 720:2009. • Full compliance with UL 2075 Simply put the detector into RealTest mode,spray a small amount • A code-required trouble relay of CO into the detector per the installation instructions,and within • Wiring supervision with SEMS terminals seconds the detector will alarm,indicating successful gas entry.(See the reverse page or the user manual for complete instructions.) • A six-year end-of-life timer • 12/24 VDC When dangerous amounts of CO are detected,the C01224T and • A low current draw of 20 mA in standby and 40 mA in alarm C01224TR detectors alert residents by sounding and flashing a temp 4 signal alarm.With 24/7 central station monitoring, residents • Versatile mounting for wall and ceiling are guaranteed protection whether they are away from home, • Accurate and reliable electrochemical sensing technology sleeping,or already suffering from the effects of CO. • Optional CO-PLATE CO Detector Replacement Plate to upgrade The C01224T and C01224TR are designed for system operation. previously installed competitor detectors to the C01224T These detectors are fully listed to UL 2075 and offer acode- required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station.The C01224T and C01224TR also use SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code-required wiring supervision.With a low current draw,these detectors enable more devices to be connected to the panel, limiting the need to purchase extra power supplies or more expensive panels.As 12/24 VDC detectors,the C01224T and C01224TR will operate on most industry security and fire alarm control panels. Agency Listings U tigTl L ry LISTED E307195 E304075 5276-1653:0194 C01224T and C01224TR Carbon Monoxide Detector Specifications Carbon monoxide(CO)detector shall be a system-connected System Sensor model number C01224T or C01224TR listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The detector shall be equipped with a sounder and a trouble relay.The detector's base shall be able to mount to a single-gang electrical box or direct(surface)mount to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide dual-color LED indication that blinks to indicate normal standby,alarm,or end-of-life.When the sensor supervision is in a trouble condition,the detector shall send a trouble signal to the panel.When the detector gives a trouble or end-of-life signal,the detector shall be replaced.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.The detector shall perform in the detection of CO up to 12,000 feet above sea level and alarm within the time specified by ANSI/UL 2034 for CO concentrations of 70, 150 and 400 parts per million(ppm),as verified by a Nationally Recognized Test Laboratory. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA(75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size:C01224T Length:5.1 in,Width: 3.3 in,Height: 1.3 in C01224TR Diameter:6 in,Height: 1.3 in Approximate Weight CO1224T:7 oz;CO1224TR: 11 oz Operating Temperature Range 32oF to 104°F(0°C to 40°C) Operating Humidity Range 22 to 90%RH Input Terminals 14 to 22 AWG Mounting Single-gang back box;surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal(standby) Blink 1 per minute — — Alarm — Blink in temp 4 pattern Sound in temp 4 pattern RealTest®Feature: The System Sensor C01224T and C01224TR Carbon Monoxide Detectors with RealTest enable evaluation of the functionality of the CO sensing cell using a canned CO test agent. �=a Push and hold the Test/Hush button for Spray canned CO agent into Verify CO sensing at the two seconds to enter RealTest mode.The the detector. control panel.The detector will green LED will flash once every second automatically exit RealTest alarm to indicate RealTest mode has started. mode after about 20-60 seconds. NOTE:Check with local codes and the AHJ to determine if a functional gas test is desired for an installation. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes(except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. �_ End-of-Life Timer: After the detector's internal sensor has reached the end of its life,a trouble signal will be sent to p the panel to indicate it is time to replace the detector.An electrochemical CO detector lifespan is about six years.The detector must be replaced by the date marked on the inside of the product. r CO-PLATE: System Sensor also offers the CO-PLATE CO Detector Replacement Plate to cover the footprint(when �� necessary)of previously installed competitive carbon monoxide detectors that require replacement. Ordering Information CO-PLATE Part No. Description CO1224T 12/24 volt,4-wire system-monitored carbon monoxide detector with RealTest®Technology CO1224TR 12/24 volt,4-wire system-monitored round carbon monoxide detector with RealTest®Technology CO-PLATE CO detector replacement plate to cover the footprint of previously installed competitive detectors as necessary 4� SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2012 System Sensor. Phone:800 SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com SENSOR`N or current product information,including the latest version of this data sheet. www.systemsensor.com scosooloo•anz SYSTEM �4 SEIVSORI" Mini-Horns -� The SpectrAlert°Advance series of mini-horn sounders are ---__ — designed to simplify installations to provide primary and secondary signaling for fire and security applications. +� SPECTRQUert A Q V A 9 &A Features The MHR and MHW mini-horns operate at 12 and 24 volts and are • 12 and 24V operation ideal for hotel,motel or residential fire system applications,where a smaller notification device is desired.The mini-horns offer high and • High and low volume settings low volume settings,and temporal or non-temporal tones. The horns • Temporal and non-temporal tones can be mounted to single gang back boxes for aesthetically sensitive • Mounts to single gang back box applications. Synchronization is also provided when using the MDL module. • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series The MHR and MHW mini-horns can operate between 32 and 120 Mini-AlertTM sounders degrees Fahrenheit from a regulated DC or full-wave rectified, • Listing for ceiling or wall mounting unfiltered power supply.They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. Agency Listings Uv ST+NG o� FM UDC �®: LISTED APPROVED �J 54011 3028007 CS1CU9 7135-16537196 SpectrAlerP Advance Mini-Horn Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box.Mini-horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems.Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified, unfiltered power supply.When used with the Sync•Circuit"Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.61 x 2.9W x .45'D Weight 2.67 oz. Operating Temperature Range 32T to 120°F(0°C to 49°C) Mounting Surface:deep single-gang back box(23/4-deep) Flush:Standard 4""x 4"back box with single gang mud ring,which allows suff icient clearance for conduit entrance. Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8-33 Operating Voltage with MOIL 9-33 UL Sound Output and Current Draw Data Sounder Output(dBA) Switch Setting Pattern Output Level 8-175 VDC 8-175 VFWR Nominal 12 Nominal 12 16-33 16-33 VDC VFWR VDC VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- High 72 71 75 74 80 79 temporal 4 Non- Low 70 69 73 72 78 77 temporal Sounder Current Draw(mA RMS) 8-175 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Ordering Information Part No. Description MHR Mini-Horn,Red MHW Mini-Horn,White 11 �`�E� ©2012 System Sensor. `` r ✓ 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject tochange without notice.Visit systemsensor.com _4 SENSOR^ Phone:800-SENSOR2•Fax:630-377-6495 or current product information,including 15 the latest version of this data sheet. AVDS0150 0•3/12 INSTALLATION AND MAINTENANCE INSTRUCTIONS SYSTEM SPECTRAs'dert SEJ VSOR OD A �V A IV. 3825 Ohio Avenue,St.Charles,Illinois 60174 Selectable Output Strobes, Horns, and Horn/Strobes 800/736-7672,FAX:630/377-6495 www.systemsensor.com For use with the following models:P2R,P2RH,P2RK,P2RHK,P2W,P2WK,132WH,P2WHK,P4R,P4RH,P4RK,NW,P4WK,P4WHK,SR,SRH,SRK,SRHK,SW,SWK,SWH,SWHK, SW-CLR-ALERT, PUR,PC2RH,PC2RK, PC2RHK, PC2W, PC2WK,PC2WH, PC2WHK,PC4R, PC4RH, PC4W, PC4WK, PC4WHK, SCR, SCRH, SCRK, SCRHK, SCW, SCWK, SCWH, SCWHK,SCW-CLR-ALERT,HR,HRK,HW,SR-P,SW-P,SRH-P,SWH-P,P2R-P,P2W-P,P2WH-P,NW-P,SCW-P,PQR-P,PC2W-P,PC2WH-P,SRK-P,SRHK-P,P2RK-P,P2RHK-P,SWK-P, snxwse SWHK-P,P2WK-P,P2WHK-P,SR-SP,P2R-SP,PC2W-SP,SRK-R,SWK-R,SRHK-R,SWHK-R,P2RK-R,P2WK-R,P2RHK-R,P2WHK-R NOTE:All-R models are specifically designed for use with the WTP Series of Weatherproof plates USTFB NOTE:When replacing outdoor units;device and back box must be replaced PRODUCT SPECIFICATIONS Operating Temperature: Standard Products 32°F to 120°F(0°C to 49°C) K Series -40°F to 151°F Humidity Range: Standard Products 10 to 93% Non-condensing K Series Meets NEMA 4X requirements Strobe Flash Rate: 1 flash per second Nominal Voltage: Regulated 12VDC/FWR or regulated 24DC/FWR Operating Voltage Range (includes fire alarm panels with built in sync): 8 to 17.5V(12V nominal) or 16 to 33V(24V nominal) Operating Voltage with MDL3 Sync Module: 8.5 to 17.5V(12V nominal) or 16.5 to 33V(24V nominal) Input terminal wire gauge: 12 to 18 AWG NOTE:Strobes will operate at 12 V nominal for 15&15/75 candela settings only.Switching between ranges is automatic. DIMENSIONS FOR PRODUCTS AND ACCESSORIES WALL PRODUCTS LENGTH WIDTH DEPTH CEILING PRODUCTS DIAMETER DEPTH Strobes and Horn/Strobes 5.6" 4.7' 2.5" Strobes and Horn/Strobes 6.8" 2.5" (including lens) 142 mm 119 mm 64 mm (including lens) 173 mm 64 mm Horns 5.6" 4.7" 1.3" SA-WBBC Weatherproof Back Box 7.1" 2.0" 142 mm 119 mm 33 mm SA-WBBCW Weatherproof Back Box 180 mm 51 mm SA-WBB Weatherproof Back Box 5.7" 5.1" 2.0'" BBSC-2 7.1" 2.2" SA-WBBW Weatherproof Back Box 145 mm 130 mm 51 mm BBSCW 2 180 mm 57 mm Back Box Skirt BBS 2 5.0"" 5.9° 2.2" BBSW-2 NOTE: SA-WBB, SA-WBBW, SA-WBBC and SA-WBBCW dimensions Back Box Skirt 130 mm 152 mm 57 mm do not include the two mounting tabs MOUNTING BOX OPTIONS 2-Wire Indoor Products 4-Wire Indoor Products K Series Products 4 X 4 x 1'/2,Single Gang,Double Gang,4"'Octagon 4 X 4 x 1'/2,Double Gang,4""Octagon SA-WBB/W(wall),SA-WBBC/CW(ceiling) NOTICE:This manual shall be left with the owner/user of this equipment. GENERAL DESCRIPTION LOOP DESIGN AND WIRING The SpectrAlert Advance series of notification appliances offers a wide range The system designer must make sure that the total current drawn by the de- of horns,strobes,and horn/strobes,for wall and ceiling applications,indoors vices on the loop does not exceed the current capability of the panel supply, and outdoors. They are designed to be used in 12 or 24 volt, DC or FWR and that the last device on the circuit is operated within its rated voltage. (full wave rectified)systems.These products are electrically backward compat- The current draw information for making these calculations can be found in ible with the previous generation of SpectrAlert notification appliances.Horn/ the tables within this manual.For convenience and accuracy,use the voltage strobe products are available in two versions.The 2-wire products fit systems drop calculator on the System Sensor website (www.systemsensor.com) or where a single NAC controls both horn and strobe.The 4-wire products are in- CD-ROM. tended for systems which have separate wiring circuits for the horn and strobe. When calculating the voltage available to the last device, it is necessary to All SpectrAlert Advance products are suitable for use in synchronized systems. consider the voltage drop due to the resistance of the wire. The thicker the The System Sensor MDL3 module may be used to provide synchronization. sire, the smaller the voltage drop. Wire resistance tables can be obtained K Series products are designed to be used over a wider range of temperatures from electrical handbooks. Note that if Class A wiring is installed,the wire and are suitable for use in wet locations. length may be up to twice as long as it would be for circuits that are not Wall and ceiling products may be used interchangeably(wall products may fault tolerant. be used on the ceiling and ceiling products may be used on the wall.) NOTE: The total number of strobes on a single NAC must not exceed 40 for FIRE ALARM SYSTEM CONSIDERATIONS 24 volt applications or 12 for 12 volt applications. Loop resistance on a single The National Fire Alarm Code, NFPA 72, requires that all horns, used for NAC should not exceed 120 ohms for 24 volt and 30 ohms for 12 volt systems. building evacuation produce temporal coded signals.Signals other than those For 4-Wire installations,terminals 1,2,and 3 connect to the strobe;terminals used for evacuation purposes do not have to produce the temporal coded sig- 4 and 5 connect to the horn. The horn and strobe circuits must be wired in- nal. System Sensor recommends spacing notification appliances in compli- dependently, and each circuit must be terminated with the appropriate EOL ance with NFPA 72. device. Removal of a notification device will result in an open circuit indica- tion on the strobe loop. D690-03-00 1 I56-2769-017R FIGURE 1.WIRING 2-WIRE PRODUCTS: TABLE 1.STROBE CURRENT DRAW(mA)FOR S,SC,P4&PC4 SERIES: INPUT Candela 8-17.5 Volts 16-33 Volts FROM OUTPUT DC FWR DC FWR FACP TO Standard Candela Range 15 123 128 66 71 OR NEXT PRIOR DEVICE 15/75 142 148 77 81 t3 DEVICE o o OR EOL 30 NA NA 94 96 + + 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 A0367-01 177 NA NA 281 251 FIGURE 2.WIRING 4-WIRE PRODUCTS: 185 1 NA I NA 286 1 258 INPUT OUTPUT FROM TO NEXT TABLE 2.CANDELA DERATING: FACP OR STROBE PRIOR Candela rating at-40°F STROBE OR EOL Listed Candela (K Series Outdoor Applications Only) 15 15/75 Do not use below 32°F + + 30 75 44 + + 95 70 110 110 115 115 135 135 INPUT FROM OUTPUT TO NEXT 150 150 FACP OR PRIOR HORN HORN OR EOL 177 177 A0366-00 185 185 FIGURE 3.SHORTING SPRING: HORN SELECTION OTurn the rotary switch on the back of the product to the desired setting. For horn and 4-wire horn/strobe products, the current draw for each setting is listed in Table 3. For 2-wire horn/strobe products (P2 series), current draws are listed in Tables 4 and 5. The sound output measurement for each horn Osetting is shown in Table 6. TABLE 3.HORN CURRENT DRAW(mA)FOR H,P4&PC4 SERIES: STRF O Pos Sound Pattern dA Out 8-17.5 Volts 16-33 Volts ® ® D7 FWR 69 FWR 1 Temporal High 57 55 69 75 0 2 Temporal Medium 44 49 58 69 3 Temporal Low 38 44 44 48 SHORTING SPRING 4 Non-temporal High 57 56 69 75 5 Non-temporal Medium 42 50 60 69 A0368-00 6 Non-temporal Low 41 44 50 50 NOTE:A shorting spring is provided between terminals 2 and 3 of the mount- 7 Coded High 57 55 69 75 ing plate to enable wiring checks after the system has been wired,but prior g Coded Medium 44 1 51 56 69 to installation of the final product. This spring will automatically disengage Coded Low 40 46 52 50 when the product is installed,to enable supervision of the final system. CANDELA SELECTION NOTE:In positions 7,8,and 9,temporal coding must be provided by the NAC. Adjust the slide switch on the rear of the product to position the desired can- If the NAC voltage is held constant,the horn output will remain constantly on. dela setting in the small window on the front of the unit.All products meet Positions 7,8,and 9 are not available on 2-wire horn/strobe products. the light output profiles specified in the appropriate UL Standards.For K series products used outdoors at low temperatures,listed candela ratings must be re- duced in accordance with Table 2.Use Table 1 to determine the current draw for each candela setting.WIRING DIAGRAMS NOTE: SpectrAlert products set at 15 and 15/75 candela automatically work on either 12V or 24V power supplies.The products are not listed for 12V op- erating voltages when set to any other candela settings.For 4-Wire products, total current draw may be determined by adding current draw for the specific candela selection in Table 1 with the current draw for the specific horn selec- tion in Table 3. D690-03-00 2 I56-2769-017R TABLE 4.2-WIRE HORN/STROBE CURRENT DRAW(mA)FOR P2 AND PC2 STANDARD CANDELA SERIES: DC Input 8-17.5 Volts 16-33 Volts 15 cd 15/75 cd 15 cd 15/75 cd 30 cd 75 cd 95 cd 110 cd 115 cd Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 TABLE S.2-WIRE HORN/STROBE CURRENT DRAW(mA)FOR P2 AND PC2 HIGH CANDELA RANGE SERIES: 16-33 Volts Volts DC 16-33 Volts Volts FWR Sound Pattern 135 cd 150 cd 177 cd 185 cd 135 cd 150 cd 177 cd 185 cd Temporal High 245 259 290 297 215 231 258 265 Temporal Medium 235 253 288 297 209 224 250 258 Temporal Low 232 251 282 292 207 221 248 256 Non-temporal High 255 270 303 309 233 248 275 281 Non-temporal Medium 242 259 293 299 219 232 262 267 Non-temporal Low 238 1 254 1 291 295 214 229 256 262 TABLE 6.HORN OUTPUT(dBA)IN UL REVERBERANT ROOM: Switch 8-17.5 Volts** 16-33 Volts** 24 V Nominal Measurements Position Sound Pattern dA Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 85 96 96 3 Temporal Low 71 71 76 76 1 81 79 94 89 4 Non-temporal High 82 82 88 88 93 92 100 100 5 Non-temporal Medium 78 78 85 85 90 89 98 98 G Non-temporal Low 73 74 81 81 86 84 96 92 7* Coded High 82 82 88 88 93 92 101 101 8* Coded Medium 78 78 85 85 90 89 97 98 9* Coded I Low 1 74 75 1 81 1 81 1 85 83 96 1 92 *Horn&4-wire Horn/Strobe only. **Minimum dB rating for Operational Voltage Range as per UL 464. MOUNTING INDOOR WALL OR CEILING PRODUCTS or ceiling using the flanges (plastic and metal back boxes) or by using 1. Attach mounting plate to junction box as shown in Figures 4 and 5.The the knockout plugs(plastic back boxes).Knockout plugs are provided to mounting plate is compatible with 4-inch square,double gang,.and 4-inch mount directly to the wall or ceiling or to a 1900 weatherproof electrical octagon junction boxes (2-wire products may be used with a single gang box,see Figure. box).If using a back box skirt,attach the mounting plate to the skirt and 3. The wall mount box must be mounted with its internal post in the lower then attach the entire assembly to the junction box(see Figures 6 and 7). left corner,as shown in Figure 8. 2. Connect field wiring to terminals,as shown in Figures 1 and 2. 4. Threaded holes are provided in the sides of the box for 3/4-inch conduit 3. If the product is not to be installed at this point,use the paint cover to adapters.Knockout plugs in the back of the box can be used for 3/4-inch prevent contamination of the mounting plate. (For indoor models only) rear entry.Unused holes must be sealed.Plugs and O-Rings are provided 4. To attach product to mounting plate,remove the paint cover,then hook with the box for this purpose. tabs on the product housing into the grooves on mounting plate. 5. It is the responsibility of the installer to make sure that all openings and 5. Then,swing product into position to engage the pins on the product with connections are sealed properly.Outdoor installations that are protected the terminals on the mounting plate.Make sure that the tabs on the back from direct exposure to rain are still subject to condensation or leakage of the product housing fully engage with the mounting plate. through hidden areas,such as a soffit. 6. Secure product by tightening the single mounting screw in the front 6. Water may pool on the back box due to condensation or direct exposure of the product housing. For tamper resistance, the standard captivated to rain or snow.Use watertight fittings for all wiring connections,includ- mounting screw may be replaced with the enclosed Torx screw. ing the knockout plugs on the back of the box.When using plastic plugs K SERIES MOUNTING to fill unused threaded holes,apply teflon tape and/or silicone sealant to 1. K Series products may be used indoors or outdoors. They must be in- reduce the chance of leakage. stalled using the proper SpectrAlert Advance weatherproof back box.Do 7. Attach the mounting plate to the weatherproof back box using the four not attempt to use boxes other than the ones supplied with the product. unpainted screws. 2. The plastic weatherproof back box is equipped with removable side 8. Follow steps 3-7 of the indoor mounting instructions to wire and attach flanges for mounting.The back box may be secured directly to the wall the product. D690-03-00 3 I56-2769-017R FIGURE 4.WALL MOUNT PRODUCT: FIGURE S.WALL MOUNT HORN/STROBE WITH WEATHERPROOF BACKBOX: C° 4-wire mounting plate � A0348-00 A0418-03 FIGURE 5.CEILING MOUNT PRODUCT: NOTE:Use all four mounting plate screws when installing outdoor units. ® FIGURE 9.CEILING MOUNT HORN/STROBE WITH WEATHERPROOF ® ® BACKBOX: 2-wire mounting plate A0369-00 v A0444-01 FIGURE 6.WALL MOUNT PRODUCT WITH BACK BOX SKIRT: O FIGURE 10.WALL AND CEILING MOUNT WEATHERPROOF BACKBOXES: O A0349-00 ° O A0417-01 FIGURE 7:CEILING MOUNT PRODUCT WITH BACK BOX SKIRT: FIGURE 11.USE SCREW DRIVER TO REMOVE KNOCK OUT: ® O O A A0424-00 0370-00 NOTE:Wall and Ceiling models may be used interchangeably(wall products may be used on the ceiling and ceiling products may be used on the wall). Please refer to insert for the Limitations of Fire Alarm Systems AWARNING The Limitations of Horn/Strobes The horn and/or strobe will not work without power. The horn/strobe gets its The signal strobe may not be seen.The electronic visual warning signal uses an extremely power from the fire/security panel monitoring the alarm system.If power is cut off reliable xenon flash tube.It flashes at least once every second.The strobe must not be in- for any reason,the horn/strobe will not provide the desired audio or visual warning. stalledin direct sunlightorareasofbighlightimensity(over60footcandles)wherethevisual The horn may not be heard.The loudness of the horn meets (or exceeds) current flash might be disregarded or not seen.The strobe may not be seen by the visually impaired. Underwriters Laboratories' standards. However, the horn may not alert a sound The signal strobe may cause seizures.Individuals who have positive photoic response sleeper or one who has recently used drugs or has been drinking alcoholic bever- to visual stimuli with seizures,such as persons with epilepsy,should avoid prolonged ages.The horn may not be heard if it is placed on a different floor from the person exposure to environments in which strobe signals,including this strobe,are activated. in hazard or if placed too far away to be heard over the ambient noise such as traffic, The signal strobe cannot operate from coded power supplies.Coded power supplies air conditioners,machinery or music appliances that may prevent alert persons from produceinterruptedpower.The strobe musthaveanuninterrupted source of powerinorder hearing the alarm.The horn may not be heard by persons who are hearing impaired. to operate correctly.System Sensor recommends that the horn and signal strobe always NOTE:Strobes must be powered continuously for horn operation. be used in combination so that the risks from any of the above limitations are minimized. Three-Year Limited Warranty System Sensor warrants its enclosed product to be free from defects in ma- Department,RA u _,3825 Ohio Avenue,St.Charles,IL 60174.Please terials and workmanship under normal use and service for a period of three include a note describing the malfunction and suspected cause of failure. years from date of manufacture. System Sensor makes no other express war- The Company shall not be obligated to replace units which are found to be ranty for this product. No agent, representative, dealer, or employee of the defective because of damage,unreasonable use, modifications, or alterations Company has the authority to increase or alter the obligations or limitations occurring after the date of manufacture. In no case shall the Company be of this Warranty. The Company's obligation of this Warranty shall be limited liable for any consequential or incidental damages for breach of this or any to the replacement of any part of the product which is found to be defective other Warranty, expressed or implied whatsoever, even if the loss or damage in materials or workmanship under normal use and service during the three is caused by the Company's negligence or fault. Some states do not allow the year period commencing with the date of manufacture.After phoning System exclusion or limitation of incidental or consequential damages, so the above Sensor's toll free number 800-SENSOR2 (736-7672)for a Return Authorization limitation or exclusion may not apply to you.This Warranty gives you specific number, send defective units postage prepaid to: System Sensor, Returns legal rights,and you may also have other rights which vary from state to state. FCC Statement SpectrAlert Strobes and Horn/Strobes have been tested and found to comply with the and can radiate radio frequency energy and,if not installed and used in accordance limits for a Class B digital device,pursuant to part 15 of the FCC Rules.These limits with the instruction manual,may cause harmful interference to radio communications. are designed to provide reasonable protection against harmful interference when the Operation of this equipment in a residential area is likely to cause harmful interference equipment is operated in a commercial environment.This equipment generates,uses, in which case the user will be required to correct the interference at his own expense. D690-03-00 4 I56-2769-017R 02012 System Sensor