Loading...
HomeMy WebLinkAboutA13-0049 data sheets A13-0049 Received Honeywell iOWN OF VAIL' r '' ° '' '. °. ° ,'o„ VISTA°-128FBPN128FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL — i � � ��� � , �t, � �� . , � ° �� :_�,. --- ,.��' �`.. , �' �.�� Now UL864 9th Edition Approved The new VISTA-128FBP provides the ultimate protection of initiating devices, notification circuits, communication devices, life and property.This UL Listed commercial fire and burglary keypads, RF receivers and relays are also supported. The control panel supports up to eight partitions and up to 128 VISTA-128FBP has been designed to mount quickly and zones/points using hardwired, wireless and V-Plex° easily in an attack resistant cabinet, and is available in 12V addressable technologies. A diverse line of Honeywell and 24V models. FEATURES • Eight hardwired zones standard, • Supports V-Plex addressable • Supports Internet and GSM expandable to 120 V-Plex VISTAKEY access control alarm reporting� addressable points/zones or (1 to 8 doors) • Supports graphical user interfaces 128 wireless points/zones .Two on-board notification (bell) for burglary use • Can control eight separate areas circuits delivering 2.3A @ 12V . Supports 6160CR-2 multi-LED independently(8 partitions) •Automatic smoke detector sensitivity fire keypad • Supports commercial wireless fire maintenance testing . Listed to UL864 9th Edition and burglary devices • Four-wire smoke reset using . Upload/download via Ethernet` • Stores up to 512 events onboard J2 output trigger • Carbon monoxide (CO) •Accommodates 150 user codes • Supports Dynamic Signaling for zone support and up to 250 access card holders AlarmNet Communicators using VISTAKEY�' � When used with AlarmNet devices. VISTA°-128FBPN128FBP-24 Honeywell COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES • Notification Appliance Circuits(two): -Individually assignable to any of - Eight zone-Class B expander module eight partitions - Programmable - Single-zone supervised contact module -Up to 16 two-wire smoke detectors each -Temporal code compliant • UL Listed wireless expansion on zone one and two(32 total) - Individually silenceable - Supports up to 128 wireless zones/points -Up to 50 two-wire glassbreak detectors • Programmable on-board auxiliary relay on zone eight - Supervised by control for check-in signals • False alarm reduction features: • Patented addressable V-Plex polling -Tamper protection for transmitters - Exit error logic loop technology - Individually assignable up to eight partitions - Exit delay reset - Supports 120 two-wire zones points - Supports commercial wireless smoke -Cross zoning - Global polling technology for faster detectors processing • Up to eight doors using VISTAKEY V-Plex -Call waiting defeat - Supervised by panel Access Control - Recent close report -Zones individually assignable to • Event reporting • Supports commercial hardwired, partitions, notification circuit(bell)output addressable V-Plex�' ollin loo and • Local printer for event log printing P g P or auxiliary relay wireless zones •Communication - 4,000 ft.capability without the use of • Hardwired zones shielded cable - Phone line, GSM and IP communicator - Provides ei ht st le B hardwired zones support 9 Y - Extender/Isolation bus modules -EOLR su ervised for Fire and UL bur la - Panel operation during download p 9 ry - Eight zone-Class A and B expander installations-Supports N.O.or N.0 sensors module Honeywell SPECIFICATIONS Applications Main Dialer Agency Listings The VISTA-128FBP control is well suited • Line seize: Double Pole • UL609 Grade A Local Mercantile for a variety of applications as an Premises and Mercantile Safe and Vault • Ringer equiv: 0.7B integrated fire and burglary control. Some of the applications supported are: • Formats: ADEMCO�Low Speed, • UL611/1610 Grades A, AA, Central medical and professional buildings, ADEMCO 4+2 Express, ADEMCO High Station churches or synagogues, office buildings, Speed, ADEMCO Contact ID, Sescoa • UL365 Grades A, AA Police Connect schools, strip malls, larger residences and Radionics • UL864/NFPA72 Local, Central and factory or warehouse environments. gackup Communication Station and Remote Station Electrical • Dual phone line capability using • UL985 • Primary power: 18VAC @ 72VA 5140DLM module • Factory Mutual Honeywell No. 1451 •AlarmNet"GSM, i-GSM and IP • California State Fire Marshal • Control panel quiescent current draw: Communicators 300mA • MEA Cabinet Dimensions • Backup battery: • CAN/ULC S304—Central and • 18" Hx14.5"Wx4.3"D Monitoring Station Burglar Alarm Unit - 12VDC, 12AH min to 34.4AH max Environmental • CAN/ULC S527—Central Unit for Fire - Lead acid battery(gel type) . Storage temp: 14° F to 158° F Alarm Systems •Alarm power: 12VDC, 1.7A max for (-10° C to 70° C) each notification (bell) circuit output • CAN/ULC S303—Local Burglar • Operating temp: 32° F to 122° F Alarm Unit Total 2.3A 12V (0° C to 50° C) • CAN/ULC S525—Audible Signal •Aux. standby pwr: 12VDC, 1A max . Humidity: 85% RH Appliances •Total power: 2.3A at 12VDC . EMI: Meets or exceeds the following • Standby time: 24 hours with 1A requirements: standby load using 34.4AH battery - FCC Part 15, Class B Device • Fusing: Battery input, aux. and - FCC Part 68 notification (bell) circuit outputs are protected using PTC circuit protectors. - IEC EMC Directive All outputs are power limited. • Optional 24-volt kit VISTA°-128FBPN128FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL COMPATIBLE DEVICES Auxiliary Devices •4208SNF Class A/B Expander Module • 5806W3 - Photoelectric Smoke • 6160CR-2 - Red Fire Keypad •4190SN Remote Point Module- Detector • 6160- Burglary Keypad two zones • 5809 -Wireless Heat Detector • 4204- Relay Module,four form •4193SN and 4193SNP Two-zone • 5817CB -Wireless Commercial C contacts Expander Modules Transmitter • 4204CF-Two supervised output V-Plex Extender/Isolation Modules • 5869 - Hold-Up Transmitter circuits •4297 Extender/Isolator Module • 5881 ENHC- RF Receiver • 5881 Series RF receiver •VSI Isolator Module • 5883H - RF Receiver • 5883H RF receiver V-Plex Smoke Detectors Access Control • 6220S -System printer used with � 4100SM serial module • 5193SD • VISTAKEY" V-Plex(addressable) •5193SDT Access Control Two-Wire Smoke Detectors • VISTAKEY-SK Starter Kit Conventional V-Plex Passive Infrared Detectors . VISTAKEY-EX Expansion Kit • System Sensor •998MX • ESL • IS2500SN Alarm Communications • DSC • DT7500SN • 7845i-ENT- Internet/Intranet Communicator Horn/Strobes V-Plex(Addressable)Contacts • 7845GSM - Digital Cellular • System Sensor •4939SN-WH Communicator • Wheelock •4944SN-WH • 7845i-GSM - Internet and Digital • Gentex •4959SN Cellular Communicator Manual Pull Stations V-Plex Glassbreak Detectors • GSMCF/iGSMCF- Commercial Fire • FG1625SN Communication Kits(when available) • 5140MPS-1 • IPGSM-DP Internet and Digital Cellular • 5140MPS-2 Optional 24V Kit Communicator V-Plex(Addressable) Devices • Order number: V128FBP924KT •4208U Universal Eight-zone Expansion Commercial Wireless Devices Module • 5808W3- Photoelectric Smoke/Heat • 4101 SN Single Relay/Zone Module Detector Product specifications subject to change. ORDERING V128FBP-9 Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V128FBP9-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model For more information:www.honeywell.com/security Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 Honeywe" P.O. Box 9040 Melville, NY 11747 wsrA,zaFaPOi� 1.800.467.5875 september 20�2 www.honeywell.com OO 20�2 Honeywell International Inc. ���:�:GFI��IF't�IEC;:�::�:�+:,�: = FEHC�',' T��i i��:f°1 6160 �- ALPHA DISPLAY KEYPAD �4 — ��*.r:�ISRR�IE����* i -i = ��AU4' T� ��`M i WITH DOOR ATTACHED ..,,�� .�.. f „ z m 3 ,:. ��_ .� a w s - i s,w. .�r. �,-., a 9.� � .,:;. a x WITHOUT DOOR The 6160 Deluxe Keypad is easy to install and simple to The oversized function keys are easily accessed even when use. The attractive white console blends with any decor and the keypad door is closed, and can be programmed for fire, features a contoured, removable door that conceals burglary, personal emergencies and other operations. Colored illuminated soft-touch keys. The 6160 also features a new self-adhesive labels are included. larger and brighter 32-character display with easy-to-read plain-English status messages. FEATURES • Large, easy-to-use keypad • Zones and system events displayed • System functions clearly labeled • Keys continuously backlit for greater in plain English • Functions performed by just entering visibility • No confusing blinking lights security code plus command • Speaker with audible beeps • Four programmable function keys • White with removable door blends to indicate: with any decor - System status - Entry/exit delay - Other alarm situations SPECIFICATIONS Physical Wiring Compatibility • 5-5/16"H x 7-3/8"W x 1-3/16"D • - (Black): Ground • Fully compatible with all (135mm x 190mm x 30mm) . + (Red): +12 VDC (Aux. Power) VISTA controls. Current • D1 (Green): "Data in"to control panel • Standby-40mA • DO (Yellow):"Data out"from •Activated Transmission-160mA control panel ORDERING 6160 Alpha Display Keypad Honeywell Security&Custom Electronics �������' Honeywell International Inc. PO Box 9035 cooso,o Syosset, NY 11791 U6160/D September 2006 www.honeywell.com o 2oos HoneyWeu inter�at�o�ai i��. Honeywell 5193S D/5193S DT V-PLEX° ADDRESSABLE SMOKE DETECTOR � ; :_ f � �r �" _� o U� Honeywell's 5193SD/SDT Addressable Photoelectric Smoke Detector is designed to provide open area protection and to be used with compatible UL-listed Honeywell control panels that support V-Plex technology. The detector incorporates a state-of-the-art optical sensing chamber and an advanced microprocessor. Built-in Drift Compensation algorithms automatically maintain proper operation at factory calibrated detection levels, even when sensitivity is altered due to the presence of contaminates settling into the unit's chamber. The 5193SDT also features a restorable, built-in, fixed temperature(135° F/57.2° C)thermal detector. FEATURES • Easy Installation: Installation of the 5193SD/SDT detector • Versatile Mounting: Mounting is made simple with the is simplified by the use of a mounting base that may be included hardware and the large mounting ports, which pre-wired to the system, allowing the detector to be easily accommodate drywall anchors for easy surface mounting. installed or removed for maintenance or service. (See (See Figure 1). Figure 1). • Tamper Protection and Tamper Resistance:The detector • LED Status Indicators:Two LEDs (green and red) provide contains a built-in tamper switch that can communicate local visual indication of the detector's status—including back to the control panel in the event the detector is normal operation, alarm, out of sensitivity and trouble removed from its base. For an added level of security, conditions. the detector also includes a tamper resistant element that • Test button:This button allows the user to perform periodic Prevents removal from the base without the use of tools. testing of the detector's circuitry and verify that the detector �See Figure 1). is within the sensitivity limits. DIRECT MOUNT HOLES B e s O SNAP OFF TAB FOR TAMPER LOCK TAMPER RELEASETAB Figure 1:Tamper-Resistant Feature/Wiring 5193S D/5193S DT V-PLEX° ADDRESSABLE SMOKE DETECTOR SPECIFICATIONS • Heat Sensor: (Model 5193SD�: • Diameter(including base): 5.3 inches 135° F(57.2° C); • Height(including base): 2.0 inches Fixed Temperature Electronic Thermistors • Operating Ambient Temperature Range: • �Neight: 6.3 oz. 32°to 100° F(0°to 38° C) • Agency Listing: UL-268 • Operating Humidity Range: • System Voltage Range: 7-14V 0 to 95% RH non-condensing • Standby Current(maximum @ 12� • Storage Temperature Range: LED off: 1.2mA -4°to 158° F(-20°to 70°C) LED on: 2.8mA ACCESSORY(sold separately) To measure the detector's sensitivity, the SENS-RDR Infrared Sensitivity Reader tool (sold separately) should be used. It reduces testing time, simplifies sensitivity measurements and displays them precisely in terms of percent per foot obscuration. The SENS-RDR eliminates the need for magnets, voltmeters and ladders. ��� °:; u . � ��R� ..... . ... O 0 , y.. Figure 2: Position of Reader �j ^- � ORDERING 5193SD Addressable Photoelectric Smoke Detector 5193SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor Accessory sold separately: SENS-RDR Handheld Sensitivity Reader Automation and Control Solutions Honeywell Security&Communications HonG��ll 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 vei9ssoTio May 2009 www.honeywell.com OO 2009 Honeywell International Inc. Honeywell 580000 CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER ` I� � � U� U�C The 580000 is a 3V battery powered wireless carbon The detector consists of an electrochemical carbon monoxide (CO) detector intended for use with Honeywell monoxide sensor assembly coupled with a wireless alarm systems that support 5800 Series wireless devices. transmitter. The transmitter can send alarm, trouble, It provides early warning when its electrochemical sensing end-of-life, tamper and low battery condition messages technology measures carbon monoxide levels in the air. to the alarm panel. The 580000 is specifically designed for system operation Since there are no holes to drill or wires to run, you can and is fully listed to UL 2075 as a system supervised preserve the beauty of the home or building while detector.� It contains a piezoelectric horn which generates protecting its occupants from harmful carbon monoxide the ANSI S3.41 temporal 4 pattern in an alarm condition. gas. The 580000 is an ideal carbon monoxide detector for difficult to wire locations, applications where room aesthetics are critical or where hazardous materials exist. What is Carbon Monoxide and How Can it Harm Consumers? Carbon monoxide (CO) is an odorless, colorless, tasteless and highly toxic gas that is produced when fuels such as wood, gasoline, charcoal and oil are burned with insufficient air. The majority of residential and commercial fatalities caused from these fuels come from heating systems, engine powered tools and charcoal grills. Carbon monoxide is harmful when inhaled because it displaces oxygen in the blood and deprives the heart, brain and other vital organs of oxygen. Large amounts of CO can overcome a person in minutes without warning—causing them to lose consciousness and suffocate. The 580000 is designed to warn the end-user well before the CO reaches a fatal level. The detector's CO sensitivity is evaluated to UL 2034. CO Levels and Time to Alarm CO Concentration Min.Time to Alarm Max.Time to Alarm 30 ppm +/- 5 ppm 30 days Indefinite`* 70 ppm +/- 5 ppm 60 minutes 240 minutes 150 ppm+/- 5 ppm 10 minutes 50 minutes 400 ppm+/- 5 ppm 4 minutes 15 minutes `For a complete list of products that support system operation of the 580000 to UL standard 2075, please visit: www.honeywell.com/security/hsc/resources/agency/co ""Life of product 580oC0 Honeywell CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER KEY FEATURES Electrochemical Sensing Technology- Electrochemical Full Supervision -The 580000 is fully supervised to monitor detectors are the newest, most refined CO detectors available for low battery, case tamper and trouble conditions. and provide the most accurate measurement of CO Test/Hush Button -This dual purpose button allows the concentration obtainable. They can take readings from low end-user to perform periodic testing of the detector. In the levels that may be hazardous over long periods of time to event of a CO alarm, this button will silence the local sounder high concentrations that present an immediate danger. alarm for a five minute period. Note: the Hush feature will not Local Sounder-A built-in piezoelectric horn generates the operate at levels above 350 ppm (parts per million)carbon ANSI S3.41 temporal 4 pattern in an alarm condition. The monoxide (see figure 1). local sounder will also alert the end-user of other conditions Versatile Mounting -Whether you choose to affix the such as low battery, detector trouble and end-of-life. detector to the ceiling or a wall, mounting is made simple LED Status Indicators - Dual LEDs provide local visual with the enclosed hardware. The mounting base has large indication of the detector's status—including normal operation, mounting ports, which accommodate drywall anchors for alarm, low battery, trouble and end-of-life (see figure 1). easy surface mounting (see figure 2). End of Life Timer-When the detector has reached the end Tamper Protection and Tamper Resistant Element - of its life, the detector will send a trouble signal to the panel. The detector has a built-in tamper switch that can This indicates that the CO sensor inside the detector has communicate back to the control panel in the event it is passed the end of its life and the detector needs to be removed from the base. For an added level of security, replaced.The detector's lifespan is approximately six years the detector also includes a tamper resistant element that from the date of manufacture. prevents removal from the base without the use of a tool (see figure 2). � � MOUNTING ' SCREWS � (INSTALLED) i . i � I / ��hJO � \ I /�v�\` � ��'��N,� J \ / � ���f \ ; ��J ' ' �I i � \ TEST BUTTON � � �� � i � ��'°nedd� � � � aa'�ow >eti�ue � ow � � �,°+� snH �o�o � d��N�Hedm I TAMPER e ao� N 1s�1 °6� � s °n+ i RELEASE TAB GREEN LED a� o� i �1l1dlF,� ��� ' CUT OFF �� 5 Q � ��'U���� t� SMALL TAB TO �O o °� i �� � ��� ACTIVATE � �` i ti �� TAMPER RESIST �q ooN°SeP � � �y \ �Z X � FEATURE) RM i Z = O O / , RED LED I � �/ i �'� Z � / � Q � � i �P � i � ENGAGE NOTCH WITH � TAMPER RELEASE TAB � ON BASE AND TURN i CLOCKWISE TO LOCK i Figure 1 ; Figure 2 580oC0 Honeywell CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER MOUNTING RECOMMENDATIONS CO is slightly lighter than air and when heated by a fuel-burning source, the lighter weight and warm temperature of the CO causes it to quickly rise to the ceiling and mix freely with the air. Check with the local Authority Having Jurisdiction (AHJ)for CO detector requirements in your area. Some recommendations for installing the 580000 are as follows: - On every floor of the facility - Inside any areas that contain a fuel-burning appliance - In the vicinity of flame-fueled appliances, but no closer than 10 feet ■ • For wall mount BEDROOM - The detector should be at least as high as a light � switch and at least six inches from the ceiling To BEDROOM gR BEDROOM • For ceiling mount � KITCHEN GARAGE - The detector should be at least 12 inches from , CLOSED LIVING DOOR any wall ROOM ■ BASEMENT � CARBON MONOXIDE ALARM LOCATION FOR MULTI-LEVEL RESIDENCE SPECIFICATIONS • Power Source: One 3V CR123A lithium battery (included) • Audible Signal (temporal 4 tone): 85 dB in alarm (at 10 ft.) • Height: 2.3" (58mm) • Diameter: 5.3" (135mm) with mounting base • Weight: 7 oz. (241 g) without battery • Operating Ambient Temperature Range: 32° F to 100° F(0° C to 37.8° C) • Operating Humidity Range: 15%to 95% relative humidity, non-condensing • Agency Listings: - Listed to UL standard 2075, 'CO sensitivity is evaluated to UL 2034 - 580000A ULC Listed - tested to the CAN/CSA 6.19.01 standard ORDERING 580000 Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter 580000A Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter with ULC listing `For a complete list of products that support system operation of the 580000 to UL standard 2075 and 580000A ULC standard, please visit: www.honeywell.com/security/hsc/resources/agency/co Automation and Control Solutions Honeywell Security&Communications Honeywell 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 U580000D/D March 2009 www.honeywell.com oO 2009 Honeyweu�nternationa��nc. �� SYSTEM _ - �. �d� � SENSOR° ,� �n � � =: —_ Mini-Horns ; � _=:�� � - ---�_ � -�-.�.., - - � -_—_�-` � -� - -� -,�--�, i � The SpectrAlert°Advance series of mini-horn sounders are �_�-.� ��--�— `�._� �—��— designed to simplify installations to provide primary and -��``=°�- � — -- �-� � � �- ---� — secondary signaling for fire and security applications. �'+� C?�� SPECTR�ert A � V A N C E Features The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications,where a • 12 and 24V operation smaller notification device is desired.The mini-horns offer high and • High and low volume settings low volume settings,and temporal or non-temporal tones. The horns • Temporal and non-temporal tones can be mounted to single gang back boxes for aesthetically sensitive Mounts to singie gang back box applications. Synchronization is also provided when using the � MDL module. • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series The MHR and MHW mini-horns can operate between 32 and 120 Mini-AlertT'"sounders degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply.They are listed to Underwriter's Laboratories • Listing for ceiling or wall mounting Standard UL 464 for fire protective signaling systems. Agency Listings U ���� o L F M I I I�+ l=��J=/ IJ Llr �k w LISTED APPROVED 54011 3028007 CS1099 7135-1653:196 SpectrAlert°Advance Mini-Horn Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box.Mini-horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems.Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified, unfiltered power supply.When used with the Sync•Circuit'M Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Dimensions 4.6"L x 2.9"W x .45"D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F(0°C to 49°C) Mounting Surface:deep single-gang back box(23/a'"deep) Flush:Standard 4""x 4""back box with single gang mud ring,which allows sufficient clearance for conduit entrance. .- InputTerminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data . Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 Nominal 12 16-33 16-33 VDC VFWR VDC VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- High 72 71 75 74 80 79 temporal 4 Non- Low 70 69 73 72 78 77 temporal _ � 8-17.5 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Ordering Information .- MHR Mini-Horn,Red MHW Mini-Horn,White l\��� �STEM 002012 System Sensor. �� 1 ✓ 3825 Ohio Avenue•St.Charles, IL 60174 P�oducts�ecit�icationssubjeatochanyewahoutnotice,Visitsystemse�soccom ��y� SE/VSORr Phone:800-SENSOR2•Fax:630-377-6495 forcurrentproductinto�mation,mdudmgme�atestve�sionofmisdatasheet. AVDS01500•3112