Loading...
HomeMy WebLinkAboutDRB130324 PLANS APPROVED2 1 0A4.01 1 A4.04 A3.04 4 A4.02 9 -83/4' 23' -23/a" 13' -0%2" 17' -4 /a" 18' -5%2' DRB130324 O O 1 5-0'' 1 10'- 23/4" in SMALL DASHED LINE REPRESENTS STONE VENEER LOCATIONS I I ABOVE- TYPICAL --------------------------- -------------------------------------------- - -. I I I T ,— A Fr I 1 %" FURRING WITH RIGID - SPA VAULT 2 FOAM INSULATION 1`, SLAB ON GRADE SURROUND al ABOVE ABOVE v MECHANICAL SUPPLY AIR DUCT - a ROUTED TO EXTERIOR ABOVE - - - F -1 F_ - - - n I I � WATER WATER � I i° TANK 2 TANK 1 `i` PROVIDE KNOCKOUT STORAGE SLAB ON GRADE IN- WALL AND b" CONCRETE BOILER 101 J ABOVE SHAFT WALLS FOR DUCT TWO a FLOOR DRAIN . BELOW SLAB - ® . EXERCISE MECH ROOM BOILER FLUES: 0 ROOM F 114 SHOWER RECESSED MOUNT TIGHT TO WALL BOILER 113 3° x 76 ELECTRIC NICHE MEDICINE L VERTICALLY ROUTE ONE CONIC PANELS CABINET TO CHIMNEY FORM \ F__ — — ABOVE la: "> L: L 5%2' 1 %'� F_ TILE 101 J b - _ 10 8 -]I - WA HER DRYER 52 30X 76 ° 1 00 �- r ­CC — — — T 12'-3Y2' VCT r o 1 %2 FURRING WITH RIGID O �I FLOOR FOAM INSULATION CLOSET - - -J = 4 00 DRAIN TWO _ -- o i ® LAUN. TILE CPT 114 CPT 109 W D 3%2 FURRING WITH ® ROOM 65 x 80 • '' INSULATION 106 13' 106 1 &4 109 _ N x 7 6 A8.01 6 6 1 1) -7 L- - LINEN- - - O STORATT7 � 18R @7" 110 W LL MOUNTED 17 T @ 1 1' 0 60sD BEDROOM IR NING BOARD v 3 x 7 TWOS 1 %2 FURRI G WITH RIGID 1%2 6' -3%2 9SD/COD 110 1 A4.03 FO M INSULATION . . . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . _ I . _I _I . . . _ _ I. — . I . . . . . . . . . . . . . . . . . . PWDR o� b 1 & 4 LOWER LEVEL F.F. i ROOM A8.01 ^ EL: 8310'-6" LIS r o b + ' 1- i i 5Y2' 17'- %4' a 108 0, I LE CPT 1 1 ' -7 %a" 3/2' c� 5 -0 5/2' 15' -b/2' 1 A3.01 102 : 1Y2' S A3.03 rcc 3 x 7N�a� 0SD CLOSET F- ---- - - - - -a - - ONE I - - ^< -N vi :� L -------- - - - - -- - __ � 104 104 1 3 %2'IFURRING WITH 24x 76 CP TILE b' -3%2' 1%2' 1 1 ' -5Y4" N INSULATION : FAMILY 1X2 ROOM �0 SOAKING ® 105 STONE PAVING 1)/2" FURRING WITH RIGID ;n BEDROOM TUB 2, -0„ 8,- NO H FOAM INSULATION ONE 5%2' S%2' - LOWER :102 = 6" STEP TERR CEL O n 00 2 DOWN 112 o A6.04 1 A H .......... .... ............................... -�._.. A4.04 0 . 103 ECESSE SLOPE 1/4" PER ° €DICIN FTFOR�OSITI�F 26 x 76 ABINET DRAINAGE. L -J 105 CPT TILE TERRACE LE EL F.F. _ EL: 8310' -0" =N 6 6 - -I N SUSPENDED PLATFORM BUILT -IN ENTERTAINMENT GAS N =1 •FIREPLACE DOOR SCHEDULE - STOCKTON RESIDENCE DOOR ROOM TYPE SIZE HINGE TEMP MATERIAL NO. NAME (VIEW FROM OUT) REFER TO SHEET A5.03 FOR GRAPHIC DOOR SCHEDULE 101 STORAGE HINGED 3'x7' L 102 BEDROOM ONE HINGED 3 Ox 7 6 L 103 BATH ONE HINGED 2 6x 7 6 R 104 CLOSET ONE POCKET 2 4x 7 6 WOOD INTERIOR DOOR 105 FAMILY ROOM SLIDING 15 6x8 6 N/A 106 LAUNDRY HINGED 3'x 7 6 R 107 NOT USED 108 POWDER RM HINGED 2 6x 7 6 R 109 CLOSET TWO HINGED 2 6x 7 6 R 110 BEDROOM TWO HINGED 3 °x 7 6 L 1 1 1 BATH TWO HINGED 2 6x 7 6 R 113 MECH. ROOM HINGED 3 °x 7 6 R 114 EXERCISE ROOM SLIDING 6 4x 8 ° 7.29.13 GLASS NOTES U -VALUE WOOD WOOD INTERIOR DOOR WOOD WOOD INTERIOR DOOR WOOD WOOD INTERIOR DOOR WOOD WOOD INTERIOR DOOR T WOOD /GLASS 0.35 WOOD EXT W/ GLASS, MOTOR SHADES WOOD WOOD INTERIOR DOOR WOOD WOOD INTERIOR DOOR WOOD WOOD INTERIOR DOOR WOOD WOOD INTERIOR DOOR WOOD WOOD INTERIOR DOOR WOOD 20 MINUTE FIRE RATED DOOR - WEATHER STRIPPING T GLASS FRAMELESS GLASS ON BARN DOOR HDWR l 6-0" l 10' -43/4" l�5%2' 18' -0" 1 1 %2' T T I I 1 A3.02 F.P. HOSE \— STEEL /WOOD BIB COLUMN 5%2'I I 4' -9%4' o 1 1/2 = I Z I n I LOWER LEVEL PLAN GENERAL NOTES: A2.01 SCALE 1/4" = 1' -0" 1. PLAN ELEVATIONS REFERENCE ACTUAL SURVEY ELEVATIONS 2. DIMENSIONED WALL OPENINGS ARE NOMINAL DIMS. U.O.N. FLOOR AREA CALCULATIONS: COORDINATE INTERMEDIATE POST DIMS. WITH WINDOW LOWER LEVEL 2,381 SQ. FT. MANUFACTURER ROUGH OPENING DIMENSIONS. MAIN LEVEL 2,210 SQ. FT. 3. PROVIDE SOUND ISOLATION OF ALL MECHANICAL EQUIPMENT UPPER LEVEL 714 SQ. FT. 4. RESIDENCE TO INCORPORATE AN APPROVED SPRINKLER SYSTEM LIVABLE AREA AND ADDRESSABLE FIRE ALARM SYSTEM 5. SMOKE DETECTORS TO BE INTERCONNECTED PER IRC CODE b CARBON MONOXIDE DETECTORS TO BE INSTALLED PER IRC R315 GARAGE AREA Design Review Staff Approval By Warren Campbell at 3:48 pm, Aug 09, 2013 TOWN OF VAIL N 6 :m Z� 5,305 SQ. FT. 731 SQ. FT. RECEIVED By David Rhoades at 8:59 am, Aug 01, 2013 POD 10� 0 U_ 0 (n � : O o � N N 0 � c1 n o h U � 0 0 A Q: 0 Q) � Q w N U LLI LLI Qch 111- 0 J li c* p TM LU cc Q LLI J J V > J J > > N Q Z 0 3 m r r Q J ISSUED FOR: DATE: SCHEMATIC DESIGN 5.1.13 CONCEPTUAL REVIEW 6.5.13 TOV FINAL REVIEW 6.10.13 MECHANICAL MEETING 6.18.13 DESIGN DEVELOPMENT 6.24.13 BUILDING PERMIT 7.9.13 PERMIT RESPONSE 7.24.13 CONSTRUCTION SET 7.29.13 CHANGE TO APPROVED 7.31.13 CD2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 114 " = 1'-0" DRAWN: MDS PROJECT A- 131303 SHEET TITLE: FLOOR PLAN A2.01 POD 0 ¢ CD _' c U Q U_ � � o PET AREA 204 TERRACE L GARAGE 202 z1a K I I - - -- _I_ J -- _' ----------------- ^I 731 SQ FT - MASTER MASTER BATHROOM BEDROOM z10 SPA N N N 0 GARAGE PET AREA z11 TERRACE STORAGE O Q 205 1 101 _ MASTER SITTING z1z • MECH EXERCISE ROOM j ROOM 114 I U -� MUD ROOM / 2F H L L--- - O — - I I 7d r E ] o POWDER MASTER v v CLOSET zos LIVING I I O a, Q ROOM zos TERRACE zn ® LAUN. YLI BATH TWO ED ROOM E LIVING Now LINEN/ Q) ROOM 213 ____ STORAG G 1oz r T 7 _i I I I I I I �� � �� �� BEDROOM TWO P 1 1 1 1 1 1 1 110 EXTERIOR ENTRY II O i T -- - -_ - -- — LO zo1 2 210 S FT Q PWDR F ROOM � ENTRY MAIN LEVEL OB o I I �� HALL zoa 2381 SQ FT o N U 01' CLOSET LOWER LEVEL ONE can 7 DINING E Q ROOM DEN 214 ROOM ROOM FAMILY zoo 1os BEDROOM OoNE L PANTRY O O LOWER TERRACE � Q D 112 RESIDENCE GRFA CALCULATIONS: BATH ONE R - 731 square foot LU 0 L LID PROPOSED AREAS: credit for the three KITCHEN LOWER LEVEL GRFA 2,381 SQ. FT. car garage C 2,a L-1 GARAGE & MAIN LEVEL GRFA 2,941 SQ. FT. B - UPPER LEVEL GRFA PROPOSED SUBTOTAL 714 SQ. FT. 6,036 SQ. FT. 0 GARAGE CREDIT (600) SQ. FT. j1 A BASEMENT CREDIT (63 %) (1500) SQ. FT. W TOTAL PROPOSED GRFA 3,936 SQ. FT. t7 Proposed GRFA Z ch ALLOWABLE GRFA 6,594 SQ. FT. 3,805 square feet J 2 MAIN LEVEL GRFA TOTAL SITE COVERAGE 3,145 SQ. FT. LOWER LEVEL GRFA AZ.08 SCALE: 1/8" = 1' -0" ALLOWABLE SITE COVERAGE 3,145 SQ. FT. A2.08 SCALE: 1/8" = 1' -0" M OC * *RE: r a SHEET A2.09 & A2.10 FOR BASEMENT DEDUCTION O O 49 =11 O v i J Q > > N O Z 3 m � IT- TF7- -TI II- -TT II 11 11 11 11 -I 11 w — — 11_11__IL_JJ_JL_ll_ IT TI-- 1r— TI - -1F_T -1 r II II II j I I 0 J CM 0 0 0 0 GUEST BATH BEDROOM 304 THREE GUEST J BEDROOM 303 LO 77 ° 714SQFT I I UPPER LEVEL I GUEST SITTING 302 HALL 301 1 — - IA l i i l l i i l l i i l i i l l 3145SQFT \��, ,�� TOTAL SITE COVERAGE EXTERIOR \ i ISSUED FOR: DATE: ENTRY o SCHEMATIC DESIGN 5.1.13 CONCEPTUAL REVIEW 6.5.13 - - - TOV FINAL REVIEW 6.10.13 MECHANICAL MEETING 6.18.13 DESIGN DEVELOPMENT 6.24.13 BUILDING PERMIT 7.9.13 PERMIT RESPONSE 7.24.13 CONSTRUCTION SET 7.29.13 CHANGE TO APPROVED 7.31.13 2013 MICHAEL SUMAN ARCHITECT, LLC. l' 1 ALL RIGHTS RESERVED. SCALE: 1/4 "= 1'-0" DRAWN: MDS PROJECT A 13003 SHEET TITLE: GRFA PLANS 4 PROPOSED SITE COVERAGE 3 UPPER LEVEL GRFA �11SCALE: 1/8" = 1' -0" Design Review Staff Approval A2.08 SCALE: 1/8" = 1' -0" A2m0 TOWN OF VA! L + By Warren Campbell at 3:48 pm, Aug 09, 2013 NORTH BASEMENT CALCULATION SCALE: 1/8" = V -Q" BASEMENT CREDIT PERCENTAGE 63% L J H F D B IUVVII yr VAILoe P ©Q 40 o U a ¢ qt � CC 0 U co 46,� S 1.1G �E �v Q � y R � yLq U 0 N U Lo co woo v) > LLI LLI z I=— O c� p a W cc a LLI O 4 O .j .j v a > > N Q Y z v 3 m � r H O J ISSUED FOR: WALL AREA CALCULATIONS SCHEMATIC DESIGN 5.1.13 CONCEPTUAL REVIEW 6.5.13 A 9' -2 1/2" x 18' -11 " 174 SQ. FT. DESIGN DEVELOPMENT B 9' -2 1/2" x 5-5 1/2" 50 SQ. FT. 7.24.13 C 9' -2 1/2" x 17' -4 1/4" 160 SQ. FT. D 9' -2 1/2" x 12' -11 3/4" 120 SQ. FT. E 9' -2 1/2 " x 7' -1 " 65 SQ. FT. F 9' -2 1/2" x 11' -1 /4" 101 SQ. FT. G 9' -2 1/2" x 6' -2" 57 SQ. FT. H 9' -2 1/2" x 19' -2 1/2" 177 SQ. FT. 19'-2 1/2" x 15' -3" 120 SQ. FT. 19'-2 1/2" x 2' -3 1/2" 21 SQ. FT. K 9' -2 1/2" x 17' -1 3/4" 158 SQ. FT. L 9' -2 1/2" x 5' -3" 48 SQ. FT. M 9' -2 1/2" x 15' -1 1/21' 139 SQ. FT. N 9' -2 1/2" x 19' -3 1/4" 177 SQ. FT. O 9' -2 1/2" x 19' -5 1/4" 179 SQ. FT. P 9' -2 1/2" x 18' -4 3/4" 169 SQ. FT. Q 9' -2 1/2" x 15' -2 3/4" 140 SQ. FT. R 9' -2 1/2" x 18' -6 1/2" 171 SQ. FT. TOTAL WALL AREA 27226 SQ. FT. WALL AREA CALCULATIONS SUB — GRADE: NORTH ELEVATION 444 SQ. FT. WEST ELEVATION 123 SQ. FT. SOUTH ELEVATION 248 SQ. FT. EAST ELEVATION 585 SQ. FT. TOTAL WALL AREA SUB —GRADE 1400 SQ. FT. BASEMENT CREDIT PERCENTAGE 63% L J H F D B IUVVII yr VAILoe P ©Q 40 o U a ¢ qt � CC 0 U co 46,� S 1.1G �E �v Q � y R � yLq U 0 N U Lo co woo v) > LLI LLI z I=— O c� p a W cc a LLI O 4 O .j .j v a > > N Q Y z v 3 m � r H O J ISSUED FOR: DATE: SCHEMATIC DESIGN 5.1.13 CONCEPTUAL REVIEW 6.5.13 TOV FINAL REVIEW 6.10.13 MECHANICAL MEETING 6.18.13 DESIGN DEVELOPMENT 6.24.13 BUILDING PERMIT 7.9.13 PERMIT RESPONSE 7.24.13 CONSTRUCTION SET 7.29.13 CHANGE TO APPROVED 7.31.13 2013 MICHAEL ' �C') ALL RIGH S RES RVED.RCHITECT, LLC. ' SCALE: 1/4 "= I'0" DRAWN: MDS PROJECT #: 1303 SHEET TITLE: GRFA DEDUCTION A2.09 T BASEMENT CALCULATION ' = 1' -011 ('�N' Staff Approval O M K I TOWN OF VA I L A By Warren Campbell at 3:48 pm, Aug 09, 2013 ¢ �ti o v v a ¢ co CC 0 U rf. w �E �v 0 �o U v1 R � ST � yLq U V N U Ql d 0 LO 0 � co r 0 N r w v) LLI LLI z � IA o o a W cc (3 LLI O 4 O .j .j v a > > N Q Y Z v 3 m 0 r H O J ISSUED FOR: DATE: SCHEMATIC DESIGN 5.1.13 CONCEPTUAL REVIEW 6.5.13 TOV FINAL REVIEW 6.10.13 MECHANICAL MEETING 6.18.13 DESIGN DEVELOPMENT 6.24.13 BUILDING PERMIT 7.9.13 PERMIT RESPONSE 7.24.13 CONSTRUCTION SET 7.29.13 CHANGE TO APPROVED 7.31.13 CC�2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 1/4 "= I'0" DRAWN: MDS PROJECT #: 1303 SHEET TITLE: GRFA DEDUCTION A2.10