Loading...
HomeMy WebLinkAboutB13-0325 PLANS APPROVED B13-0325 � W J � E � � o w � �' 158 EAST GORE CREEK DRIVE UNIT 132 a � � � � � VICINITY MAP — VAIL CORE SHEET INDEX • � � ° � ;� �� ��� _ -_ VAIL COLORADO 81657 � � .- _ � - • � � w - � � �. �_,� � � � � �. � � 1i _ f , ��� , ._ - � PuaucRESTROOMSa ARCHITECTURAL I � � � � �. A1.0 COVER AND PLAN SHEET . -� M.�..,. ._:. .: � �2 L ;�� , CHECKPOINT CHARLEY r f, � � � N � � � . . , ,rX`' i , , `, - „ � . ._ r � ._� ��µ ��c `-� �L' M � 'C , . _ , .. "� :� ,o � � � , : -�.--- � - � - � `� X cv ��T`' � °��� , MECHANICAL & PLUMBING ° � ' � �`, "�,�, - �` ,' � ---+- �!'..��° � � MP1.0 DETAILS & SPECS � °' °�° � ��� � � � � `"'� MP2.0 PLAN & SCHEDULES � "# � _ � � *� ±` t.�. f� �. ��: } _� � a � �: �, �: ,, � ; � � : _ .: : 3 <. ti ;�, ,,�- ,�" � ---_ � . � ' ' ' _ ,� STORE LOCATION �� �{� Y ; , ._ y s�-2° 11�-s° �'-s° �� '` �,,' ;�� "�T ���"` ELECTRICAL '=. . '�' ., �� ' � O���F'Y � � . .. .,� I ._ , " '�' . . r ` �.�. ... b.. .. , E1.0 SPECS AND ONEU ES _ _--� _ -, ''�'- .�� - � ALL FIXTURE AND APPLIANCE N � �a��� �w���� � � _:- == � `".'` �� E2A ELECTRICAL PLAN 'e���a A_ � ��, �:.; ���;� „� , � � _ - SPECS SHALL BE PROVIDED � � - �, _ � _, f :,� � "i � ��'"' ��� ' � -} BY THE OWNER SWITCH DOOR SWING NE TRIPLE SINK � ' 1 � ,- l' � • • �.� � PUBLIC RESTROOM ., . � 1 , :.� � �����" ' _ -- � NE FLOOR SINK ,� '� ° -� �' " 'V � 7�� ,�- �. ° > . � y � �' �. --> a .: '' � r `° � - EXISTING TOILET _ F y �+�-., �, �T � P.� � u N ,I _ � � TILE WALL R'� ' 1 .q _ l . �r � �,_ f. /� p � ,. �'. � � l�,��I ��.;. ,.� .,� �I �� _._ �a� � �� ' � '� � AIRCOND. �� � + � i ��''� /rl.. � _ , \ w- f I" NEW TUB FLOOR DRAW � • � � '� � ..�,� r.,.� � _` ����.,I w . � i i � .�'�� � � , . i � ._ �.�- , ��.,� � ; , � ' DRAIN TO TIE NTO EXISTIN L—_____ SINK SWK ! swK � ','. � ;' � ° : , . - -,- `'' �'�� DRAINABOVEISTRUCTUREG ` J - , ^!� ` � •:: �F�. _ � _ REMOVE SMALL PORTION r '� � a ��,'. TENANT SPACE LOCATION Z ' `r ' � I f I j i I r �'' ti FLOOR SWK NOTE OF EXISTWG WALL � �' ��^ LODGE AT VAIL BLDG. O o �� � �� � � � I � � "' 12X12 FLOOR SWKS WILL REQUIRE / � ! ...`��_'� � � _ iM:d'� � Cn a � r �� , � � � _ i I — NEW MTL.WALLS W/ � w •y ��y 'n DRAIN PIPE PENETRATION THROUGH DRYWALL TO MATCH , _:� ' � _ �� STRUCTURAL CONCRETE T-BEAMS INTO � � � �� EXISTING v � �y�"+'��''�r . f � "°:. �a�� � � � GARAGE BELOW. ,% / v � o �����,,,�. M PROJECT INFORMATION � EXISTING SINK AND CABINET SODA 3'-1" '�NOER- � Pro ect Descri tion: The unit is to be converted from the retail s ace into a chocolate retail sho . The existin unit YOGURT ❑ FRIG FRIG COUNTER �- GRAPHICS � � p p p g %' � FR'� � N is the have some interior partitions and flooring removed. The unit's perimeter walls, floor, and ceiling are to Z �� �_ [ �� _ ' ` � �r� � - � - - � remain mainly in tact except for the required plumbing, fire, and HVAC need penetrations (or access to run ��' `� ��� �:, � '' `- _ a� ,_ _ � �� �, NEw F�ooR siNK - _ � piping/ducts). The bath will remain private (non-public) and will see the addition of a mop closet. Sinks, and - NEW TILE _ GRAPHICS FLOORING `� drains will be added to the rear space. Electric ovens, refridgerators, and other appliances will be added in the �-�- � � � CANOPY SIGN TO BE REPLACED GRAPHICS (BY OWNER) M _ � main space. The front area will be used for customer/sales. No ceiling changes are proposed. No dining areas / USING SAME FRAME MITSUBISHI AIR-CONDITIONER � ° area proposed. No exterior renovations are proposed. The sign framework will remain and the sign replaced. � UNITS IN 3 LOCATIONS HIGH ON � � , w WALL. CONNECTED TO A NEW \ —� P.O.S. 9'CASE � ��=-- . � 3'-5° ,� GRAPHICS Commercial Renovation: Tenant Build-out Class of Work: Renovation/tenant build-out / COMPRESSOR WHICH WILL BE � o ' _ , �, � ; ) , .'� ; i _ INSTALLED IN THE GARAGE o i a . , , , �'� _ ._,_,,;:-�_;; . � �r�, � ; ,. _ `° BELOW. � � 3'-�" `� � � Q , J Location: Type of Construction: Type II-B p }'. �� � � �.: , , X�:x�; N 158 E. Gore Creek Drive, Unit 132 —J O O � `a �� ,���:�, s�-9° � 9�-o�� ��-s° Lodge at Vail Building Type of Occupancy: Business (Mercantile) � ���,�� i '��°. ;� � � � � Vail, CO 81657 � �- i _ ' � �� ��� -- N � C�� - �- Vail Core Commercial Sprinkler System: No change to existing ceiling or layout � � t'�� ,,;� _ z i �.i . - , ��,. a W o = �'`, ch of existin s rinkler s stem. , � �:� � a NEW HAND SINK - o� � ' „� � -Y�, " : ��.��: e N = OO a � a _ g p Y � � �..r-�; � _ � � T n a n t: R o k M u n t a i n h l a t F c t � - � o e c o C oco e a o 2' 1" � - y � _ . - - � .,. �r ,.. °,�,�;�.� �.i' �v=` ,.:�. --� 1 —�--'---• — � �° �� FL OROOD i a N Brad Maxwell Levels: 1-story unit. Building is 3 story + basement ---- � �- � -� - _-., ELECTRIC COOK STOVE ----i (BY OWNER) L 24 Choke Cherry St. Edwards, CO 81632 - ` � �RaPHics ; fi 970-376-3148 Occupancy Load: �= �; NO CHANGE TO FRONT FACADE , bamaxwell@live.com Public Mercantile Area = 218 sq. ft. /30 = 7 persons � . SMALL REPAIRS ONLY ; � Storage Mercantile Area = 422 sq. ft/300 = 2 persons ,_� " . � _,�..� COPPER HOOD AND EXHAUST - -� W C011tl'aCtOC: By OWII@I' Total Occupant Load = 9 persons ' `" � PIPE. FOR AESTHETICS ONLY, i i � � , _ • � . . �`'. . NOT REQUIRED BY CODE. � � a � �� ��°'�� - �� � � Architect: Martin Manley Architects Exit Width = 9 people x .02 inches = .18 inches � � � °'SP`AY Z John G. Martin, AIA Existin 36" door rovided. � _ 9 P V •� � � LL PO Box 4701, Eagle, CO 81631 � � � � > �i � $�_9�� 970-328-0592 Plumbing Toilet Location is <500 ft and the tenant has '�,. : - ' ' john@martinmanleyarchitects.com use by lease agreement. A public restroom is also located � NM � I EXISTING BASEBOARD EXISTING BASEBOARD within 500 ft. � `-J . /— NO CHANGE TO CEILING ,°�� �� ExisTiN�wiN�ow ExisriN�wiN�ow � Mechanical � EAEC Arch tectueal En ineerin Consultants � � - �. - �j ^ I I 9 9 — � AREA SUMMARY: �isP�aY DISPLAY Stan Humphreys Q � � r� � r' � RETAIL AREA = 640 S.F. � ` � PO Box 8489, Avon, CO 81620 L U -�-� �__,��--- ' � t -- - - • RESTROOM AREA= 36 S.F. I I � � � ' `° � `=� - 970-748-8521 0 > , � - � TOTALAREA = 676S.F. � - - - - - - - - - - - - - - - - - - - - - � . X '� , . . �.- � - - - - - - 25�-s,� stan@aec-vail.com c6 � .�, _ � m U o �� � ��� EXISTING EGRESS DOOR TO REMAIN � � � � � . � , � _ �-- '^ '' � LWE OF CANOPY SIGN ABOVE. PIUlllblllg: Keltfl DII1gIeWItZ � ._ � � � OWNER TO RE-USE FRAME AND REPLACE SIGN. 970-390-5447 � (� L 3 � DESIGN BY OWNER. CIIelIgIeWICZCI@aOLCOf11 � � �..� �� A1.0 EXISTING SLOPING CONCRETE SIDEWALK � L , . � - �� - - 0 �� � ` - � ``_ '�` - --�I - 0 �I''� � � f , �� V _�� � �� �.�ti � � � � � � �-���, � Mai�n Level�� w '� ��, :� �-- 1/4 - 1 -0 � � w ��� � . � r:� _ `� O � y �;. ,vt:.. � 1 } ���, .,- 1'.���i�1T � ,�� s.;y��� NO CHANGE TO FLAT CEILING �� �, �„�'�, ��;��a •�1� � � _ � . r, , . � > >�- ��;���� ;� AIR-CONDITIONING HOTEL ROOMS ABOVE �', � _' � , �;��"'' COMPRESSOR LOCATION IN `'��� � ��''� � � � BASEMENT GARAGE � `,� � � �'�� :-.-5..,�_✓ - _.�„�-� - - �} " '� � '" ' �'�: , _ PLATE AT 7-8 � - .��__ r�. � " `1�= vr �_ � �,,� , ���,�J �` � °.�..,,_ �._ � y; i ,..�s-�r.a+r7 �i:+ „ ;`' ` � ...:- -3�r���.'iG�-.-�--���, .u�:. . --� '�+'+�..wr.-4-�-•- �v�. . .�� :� ,�.� - . _,.�.�...�.:a�.._ ,,.�.....,�... _�z . _ . y.. — — — - — — — %— — — �=�f c+� `",i', �,� _� . , , = Upper Level , . `� � � _ � RIDGE AT 10'-0" ��� �� �. }� - 7� 8�� / � � �`'. :- '� __--- ��_ +�_�. t;� -_-----�---= � , �'�� NO CHANGE AT DROPPED CEILING —� f � � � j I / I, '., � � +� r' . � - ° \�--� t""� c _ . j o � , - STREET �..�,; '� `�j 1 ' NOTE: ��: o �\�%�, � ,t,. %` � NO CHANGE TO CEILING DRYWALL. �-�_��v�'_ � �'' �` `E ! �- NO CHANGE TO LIGHT FIXTURES r t =,,,` f � �; NO CHANGE TO FIRE SPRINKLER AND ;:; ALARMS. � , _. - _. ,.,,., _ . _ M � Main Level � '+��"' �i MMr♦ �L,,,�, _ . � - , _ . . a, � , - - . , . , ._ . - .�_ - .. . . . �y' On �., � a � � � ,r:; . ��.�' � ti�" ,�� ;ro _ � 7G Zq y _�r. �� J y ry �� ' �'� PARKING GARAGE BELOW � , , x� .; � ;,:� . � r ?r'�.s ,,.q .tnNC�'" '. �l�F '�*��-^�' 6�' : � , :�,;a O O . 0 ■ � � a p N � Section 1 2 Main Level � Q � 1/4" - 1'-0" 1/8" - 1'-0" .n � � � M � W ° � O U � � RECEI VED � �� " By David Rhoades at 1:30 pm, Aug 07, 2013 � � O M EC HAN I CAL S P EC I F I CATI O N S. h. EACH MECHANICAL VENTILATION SYSTEM (SUPPLY AND/OR EXHAUST)SHALL BE EQUIPPED WITH A MEANS OF 24. FINAL LOCATION OF GRILLES, REGISTERS & DIFFUSERS SHALL BE PER THE ARCHITECTURAL PLANS, ELEVATIONS 11. CLEANUP: Cfl SHUT-OFF WHEN VENTILATION IS NOT REQUIRED,AND BACKDRAFT DAMPERS WHICH CAN BE CLOSED ON FAN OR AS PER FIELD REQUIREMENTS. a.UPON COMPLETION OF THE WORK UNDER THIS SECTION, THE CONTRACTOR SHALL REMOVE ALL SURPLUS � SHUTDOWN SHALL BE PROVIDED FOR AIR INTAKES AND/OR DISCHARGES. MATERIA�S, EQUIPMENT AND DEBRIS INCIDENTAL TO THIS WORK AND LEAVE THE PREMISES CLEAN AND 1. GENERAL: i. CLEAN OUT ALL DUCTS PRIOR TO SUPPLY AND RETURN GRILLE INSTALLATION 25. THE GENERAL CONTRACTOR SHALL FURNISH & INSTALL ALL OF THE REQUIRED ACCESS PANELS IN THE ORDERLY. +�-+ � a.FURNISH ALL LABOR, SUPERVISION, MATERIALS, EQUIPMENT AND FACILITIES NECESSARY TO FURNISH, j. DOUBLE THICKNESS TURNING VANES SHALL BE USED ON ALL DUCT TURNS OF 90°. DRYWALL CEILINGS TO GAIN SERVICE ACCESS TO THE EQUIPMENT. EQUIPMENT WITH MANUFACTURER MANDATED � cA � � � FABRICATE, DELIVER, STORE AND INSTALL ALL WORK NOTED ON THE DRAWINGS AND/OR SPECIFIED HEREIN. SERVICE REQUIREMENTS INSTALLED WITHIN CRAWLSPACES MUST BE A MAXIMUM OF 20 FEET FROM AN ACCESS 12. PLUMBING IDENTIFICATION (� V � p N b. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL WORK NECESSARY TO MAKE A COMPLETE SYSTEM 14. REFRIGERANT PIPING: PANEL. a.EQUIPMENT NAMEPLATES: METAL, WITH DATA ENGRAVED OR STAMPED, FOR PERMANENT ATTACHMENT ON }' � p � WHETHER OR NOT SUCH DETAILS ARE MENTIONED IN THESE SPECIFICATIONS OR SHOWN ON THE PLANS, BUT a.REFRIGERANT LINE SETS SHALL BE FURNISHED BY THE CONDENSING UNIT MANUFACTURER AND BE EQUIPMENT. � � � U ' WHICH ARE OBVIOUSLY NECESSARY TO MAKE A COMPLETE SYSTEM, EXCEPTING ONLY THOSE PORTIONS THAT PRE-INSULATED. 26. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S INSTALLATION, OPERATION & b. PIPE MARKERS: PREPRINTED, COLOR CODED, WITH LETTERING INDICATING SERVICE,AND SHOWING DIRECTION V� � N � ARE SPECIFICALLY MENTIONED HEREIN OR PLAINLY MARKED ON THE ACCOMPANYING DRAWINGS AS BEING b. REFRIGERANT PIPING CONNECTIONS SHALL BE BRAZED WITH 15% SILL FLOSS. PURGE PIPING WITH NITROGEN MAINTENANCE MANUAL'S RECOMMENDATIONS ESPECIALLY FOR SERVICE CLEARANCES. OF FLOW. � � � p � INSTALLED UNDER ANOTHER SECTION OF THE SPECIFICATIONS. WHILE BRAZING. c. VALVE TAGS: STAMPED OR ENGRAVED WITH 1/4" LETTERS FOR PIPING SYSTEM ABBREVIATION AND 1/2" O �O � O c. PROVIDE HANGERS, SUPPORTS AND INSULATION SADDLES AS REQUIRED AND PER ANSI REQUIREMENTS. 27. FILTERS: NUMBERS, WITH NUMBERING SCHEME. PROVIDE 5/32" HOLE FOR FASTENER. r , � L a ~ 2.W O R K M A N S H I P: PLUMBERS TAPE AND WIRE ARE NOT ACCEPTABLE. a.SHALL BE UL RATED AND APPROVED. d. VALVE TAG SCHEDULE: PREPARE A VALVE TAG SCHEDULE TO BE SUBMITTED TO THE MAINTENANCE ENGINEER v � � � � � a.THE W ORK SHALL BE A C C OMPLI SHED IN A TH OR O U GH AND W ORKMAN-LIKE MANNER SATI SFA CT ORY T O AND d.REFRIGERANT PIPING INDICATED IS SCHEMATIC ONLY. SIZE PIPING AND DESIGN THE ACTUAL PIPING LAYOUT, b. PRESSURE DROPS SHALL NOT EXCEED .10"STATIC PRESSURE. FOR RECORD. � N � X O MEETING THE APPROVAL OF THE OWNER AND ARCHITECT. INCLUDING OIL TRAPS, DOUBLE RISERS, SPECIALTIES, AND PIPE AND TUBE SIZES,TO ENSURE PROPER � �'~ N ci3 U � � � LL_ OPERATION AND COMPLIANCE WITH WARRANTIES OF CONNECTED EQUIPMENT. 28. ELECTRICAL CONNECTIONS: 13. PIPE INSULATION: �� }' N }' 3.MATERIALS: e. EVACUATE THE ENTIRE REFRIGERANT SYSTEM WITH A VACUUM PUMP TO A VACUUM OF 500 MICROMETER FOR a.UNLESS OTHERWISE INDICATED ALL MAGNETIC MOTOR STARTERS,THERMAL OVERLOADS, LOW VOLTAGE a.DOMESTIC WATER PIPING INSULATION SHALL HAVE A THERMAL CONDUCTIVITY LESS THAN OR EQUAL TO 0.27 N � U � .� a. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND THE BEST OF THEIR RESPECTIVE KIND, FREE FROM ALL A PERIOD OF 12 HOURS PRIOR TO CHARGING. THERMOSTATS, CONTROL RELAYS, CONTROL TRANSFORMERS AND SOLENOID VALVES SHALL BY FURNISHED BTU-IN/HR-FT2-OF. N ,J V � N � DEFECTS AND OF THE MAKE AND QUALITY SPECIFIED. BY THE MECHANICAL CONTRACTOR. b. HOT&COLD WATER SUPPLY PIPING (EXCEPT RUN OUTS 12 FT. OR SHORTER TO INDIVIDUAL FIXTURES)SHALL � � a � � � 15. DUCTWORK INSULATION: b. PROVIDE MOTORS AND EQUIPMENT FOR ONLY THOSE CURRENT CHARACTERISTICS INDICATED ON THE BE INSULATED AS FOLLOWS: � , 4.SITE INSPECTION: a.ALL DUCTWORK SHALL BE INSULATED CONSISTENT WITH THE REQUIREMENTS PER SECTION 604 OF THE 2009 DRAWINGS. PIPE SIZE (IN.) INSULATION THICKNESS (IN.) .� � � � � � a. CONTRACTOR SHALL VISIT THE SITE OF WORK PRIOR TO SUBMISSION OF HIS BID AND THOROUGHLY IMC. c. IT IS THE INTENT OF THIS DIVISION TO REQUIRE A COMPLETE SYSTEM PER THE CONTRACT DOCUMENTS. 1/2", 3/4"& 1" 1" � '� w �'� � FAMILIARIZE HIMSELF WITH THE WORKING CONDITIONS &EXACT NATURE OF THE WORK. b. INSULATION SHALL BE UL LISTED IN COMPLIANCE WITH A FLAME-SPREAD INDEX NOT MORE THAN 25 AND d.COORDINATE ALL EQUIPMENT REQUIRING ELECTRICAL POWER, REGARDLESS OF VOLTAGE, WITH OTHER 1 1/4"THROUGH 6" 1 1/2" w V J 2 O � b. SUBMISSION OF A BID ACKNOWLEDGES FULL RESPONSIBILITY FOR FURNISHING A COMPLETE AND FUNCTIONAL SMOKE DEVELOPED INDEX NOT MORE THAN 50, PER THE 2009 IMC. INSTALLATION SHALL BE IN ACCORDANCE TRADES, SO THAT ALL SYSTEMS ARE COMPLETE AND OPERATIONAL. c. NO HOT OR COLD WATER PIPING SHALL BE ROUTED IN EXTERIOR WALLS UNLESS PROPERLY INSULATED. - � � � ti � SYSTEM. WITH IMC REQUIREMENTS. e.ALL THREE PHASE MOTORS SHALL BE PROVIDED WITH PHASE LOSS PROTECTION. d. CONDENSATE PIPING SHALL BE INSULATED WITH 3/8" FOAM PLASTIC. � W +r � � c. NO CHANGES IN CONTRACT WILL BE MADE TO ACCOMMODATE OR ALLOW EXTRA FUNDS FOR ANY OMISSION c. RECTANGULAR SUPPLY, RETURN &TRANSFER DUCTWORK SHALL BE INTERNALLY LINED WITH A VAPOR f. ALL SINGLE AND THREE PHASE MOTORS, STARTERS AND DISCONNECTS PROVIDED BY MECHANICAL � � � � � WHICH RESULTS FROM A FAILURE TO THOROUGHLY MAKE THE EXAMINATION. RESISTANT DUCT LINER OF THICKNESSES SPECIFIED BELOW. CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR. 14. PIPING: ♦'' U � O C d.CONCEALED ROUND, CONCEALED OVAL &OUTDOOR AIR DUCTS SHALL BE EXTERNALLY WRAPPED WITH a. WASTE AND VENT DRAIN PIPING: V '� .V o0 O 5.CODES AND PERMITS: FIBERGLASS INSULATION WITH AN EXTERNAL VAPOR BARRIER. REQUIRED R-VALUES ARE SPECIFIED BELOW. 29. TEMPORARY HEATING DURING CONSTRUCTION: i. SHALL BE STANDARD WEIGHT CAST IRON HUB LESS TYPE. � � � � � a. ALL MECHANICAL EQUIPMENT, INSTALLATION, ETC., SHALL CONFORM TO THE 2012 INTERNATIONAL MECHANICAL e. ALL SUPPLY, RETURN &TRANSFER DUCTWORK LOCATED WITHIN THE BUILDING ENVELOPE SHALL BE a.MECHANICAL EQUIPMENT SHALL NOT BE UTILIZED FOR TEMPORARY HEATING. ii. UNDERGROUND PIPING CAN ALSO BE SCHEDULE 40 PVC. �- V O � N CODE (IMC), 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)AND ORDINANCES AS INTERPRETED BY INSULATED TO A MINIMUM OF R-4 (1" LINER) UNLESS SPECIFIED OTHERWISE ON THE PLANS. b. GAS FIRED TEMPORARY HEAT SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. iii.VENT PIPING IN RETURN AIR CEILING PLENUMS SHALL BE ABS OR COPPER PIPING. � � � � N THE TOWN OF VAIL BUILDING DEPARTMENT. f. ALL SUPPLY& RETURN DUCTWORK SHALL BE INSULATED TO A MINIMUM OF R-5 (1-1/2" LINER)WHEN LOCATED IN b. WATER PIPING: V � Q � � b. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS. UNCONDITIONED SPACES AND SHALL BE INSULATED TO A MINIMUM OF R-8 (2" LINER)AND WEATHERPROOFED i. SHALL BE TYPE"L" COPPER HARD DRAWN WITH WROUGHT COPPER FITTINGS. L � c. COPIES OF ALL PERMITS AND INSPECTION REPORTS SHALL BE SUBMITTED TO THE ARCHITECT. WHEN LOCATED OUTSIDE THE BUILDING. P L U M B I N G S P EC I F I CAT I O N S. ii. JOINTS SHALL BE SOLDERED WITH 95-5 OR SILVER SOLDER. � � g. ALL OUTDOOR AIR DUCTS SHALL BE INSULATED TO A MINIMUM OF R-6 WITH A VAPOR BARRIER. iii.WATER PIPING 1 1/4" &SMALLER CAN ALSO BE WIRSBO AQUAPEX APR, REHAU RAUPEX OR EQUIVILANT-PROVIDE m 6.AS-BUILTS: 1. GENERAL: DEDUCT ALTERNATE PRICING. 0 a. CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS-BUILT DOCUMENTS WITH ALL CHANGES NOTED 16. PIPING INSULATION: a.FURNISH ALL LABOR, SUPERVISION, MATERIALS, EQUIPMENT AND FACILITIES NECESSARY TO FURNISH, c. CONDENSATE PIPING SHALL BE TYPE "M" COPPER WITH SOLDER JOINTS. � THEREON AT THE COMPLETION OF THE PROJECT AND PRIOR TO FINAL ACCEPTANCE AND PAYMENT. a.ALL HYDRONIC PIPING SHALL BE INSULATED CONSISTENT WITH THE REQUIREMENTS PER SECTION 1204 OF THE FABRICATE, DELIVER, STORE AND INSTALL ALL WORK NOTED ON THE DRAWINGS AND/OR SPECIFIED HEREIN. 2009 IMC. b. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL WORK NECESSARY TO MAKE A COMPLETE SYSTEM 15. EACH PLUMBING VENT SHALL TERMINATE NOT LESS THAN TEN FEET FROM ANY MECHANICAL INTAKE AND AT 7. GUARANTEE: b. INSULATION SHALL BE UL LISTED IN COMPLIANCE WITH A FLAME-SPREAD INDEX NOT MORE THAN 25 AND WHETHER OR NOT SUCH DETAILS ARE MENTIONED IN THESE SPECIFICATIONS OR SHOWN ON THE PLANS, BUT LEAST THREE FEET FROM ANY OPENING INTO THE BUILDING. _.,�u�:�ir�rr�r a. CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL LABOR AND MATERIALS ON ALL WORK AGAINST SMOKE DEVELOPED INDEX NOT MORE THAN 450, PER THE 2009 IMC. INSTALLATION SHALL BE IN ACCORDANCE WHICH ARE OBVIOUSLY NECESSARY TO MAKE A COMPLETE SYSTEM, EXCEPTWG ONLY THOSE PORTIONS THAT �¢�0`:���, i��:� ��*f,r� DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER COMPLETION. WITH IMC REQUIREMENTS. ARE SPECIFICALLY MENTIONED HEREIN OR PLAINLY MARKED ON THE ACCOMPANYING DRAWINGS AS BEING 16. CLEAN-OUTS SHALL BE INSTALLED AS PER 2009 IPC SECTION 708. ���`J� rfi ''�� c. ALL HYDRONIC PIPING INSULATION SHALL HAVE A THERMAL CONDUCTIVITY LESS THAN OR EQUAL TO 0.27 INSTALLED UNDER ANOTHER SECTION OF THE SPECIFICATIONS. � <• r^ 8.SUBMITTALS: BTU-IN/HR-FT2-OF. 17. PROTECT ROOF RECEPTOR ON ROOF FROM RAIN WATER BY ELEVATING THE RIM 2 '/2" INCHES ABOVE ROOF �- `` a. CATALOG INFORMATION AND CUTS OF ALL EQUIPMENT AND DEVICES SHALL BE SUBMITTED TO THE ARCHITECT d. ALL HEATING WATER PIPING 1-1/2" OR SMALLER SHALL BE INSULATED WITH 1-1/2"THICKNESS. HEATING WATER 2.WORKMANSHIP: SURFACE. � 29840 � ' � FOR REVIEW (SIX COPIES OF EACH). PIPING LARGER THAN 1-1/2"SHALL BE INSULATED WITH 2"THICKNESS. a.THE WORK SHALL BE ACCOMPLISHED IN A THOROUGH AND WORKMAN-LIKE MANNER SATISFACTORY TO AND � �.��� ` � � `4 e. ALL CHILLED WATER PIPING SHALL BE INSULATED WITH 1-1/2"THICKNESS WITH AN APPROVED VAPOR BARRIER. MEETING THE APPROVAL OF THE OWNER AND ARCHITECT. 18. PROVIDE WATERTIGHT FLASHING WHEREVER PIPES PASS THRU EXTERIOR WALLS, ROOF AND FLOORS. �� �3�Z-� ; 9.COORDINATION: f. ALL PIPING ROUTED BELOW THE SLAB UNDERGROUND SHALL BE TYPE"k" COPPER AND SHALL BE INSULATED ��� f' <��� ,�' a.THE DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW SCOPE. WITH ARMIFLEX TYPE INSULATION. 3. MATERIALS: 19. PENETRATION IN WALLS REQUIRING PROTECTED OPENINGS SHALL BE FIRE-STOPPED. FIRE-STOPPING SHALL BE �rr���S,cyONpLE:}1i,'" b. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES TO PROVIDE BEST ARRANGEMENT OF a.ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND THE BEST OF THEIR RESPECTIVE KIND, FREE FROM ALL AN APPROVED MATERIAL SECURELY INSTALLED AND CAPABLE OF MAINTAINING ITS INTEGRITY WHEN SUBJECTED ���'�x��� ALL DUCTS, PIPES, CONDUIT, ETC. 17. TEMPERATURE CONTROL DEVICES: DEFECTS AND OF THE MAKE AND QUALITY SPECIFIED. TO TEST TEMPERATURE FOR SPECIFIC WALL OR PARTITION. a.THE HVAC SYSTEM SHALL BE PROVIDED WITH 7-DAY PROGRAMMABLE AUTOMATIC SPACE TEMPERATURE 10. CUTTING AND PATCHING: CONTROL DEVICES (THERMOSTATS)AS SHOWN ON THE PLANS. THE THERMOSTATS SHALL BE CAPABLE OF 4.SITE INSPECTION: 20. PROVIDE FELT WITH METAL BACKING VIBRATION ISOLATION SLEEVES OR PADS AT ALL PIPE HANGERS OR a. ALL CUTTING AND PATCHING REQUIRED OF THE STRUCTURE (NEW OR EXISTING)SHALL BE PROVIDED UNDER SCHEDULING OCCUPANCIES AND PROVIDING SETBACK CAPABILITIES TO MAINTAIN ZONE SETPOINTS DOWN TO a.CONTRACTOR SHALL VISIT THE SITE OF WORK PRIOR TO SUBMISSION OF HIS BID AND THOROUGHLY SUPPORTS AND ALL POINTS WHERE PIPING COMES IN CONTACT WITH ANY PORTION OF THE STRUCTURE. APPLIES OTHER SECTIONS OF THE WORK. 55°F OR UP TO 85°F. FAMILIARIZE HIMSELF WITH THE WORKING CONDITIONS& EXACT NATURE OF THE WORK. TO ALL WATER AND WASTE PIPING. b. PROVIDE NECESSARY REQUIREMENTS TO THE PROJECT SUPERINTENDENT. b. CONTROLS SHALL BE CAPABLE OF OPERATING THE SYSTEM HEATING AND COOLING IN SEQUENCE AND SHALL b. SUBMISSION OF A BID ACKNOWLEDGES FULL RESPONSIBILITY FOR FURNISHING A COMPLETE AND FUNCTIONAL � � c. X-RAY SLABS PRIOR TO CORING. BE ADJUSTED TO PROVIDE A DEADBAND OF AT LEAST 5°F BETWEEN HEATING AND COOLING. SYSTEM. 21. LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE. CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND c. THERMOSTATS SHALL HAVE NUMERIC SET POINTS IN °F,ADJUSTABLE SETPOINT STOPS AND SHALL BE c. NO CHANGES IN CONTRACT WILL BE MADE TO ACCOMMODATE OR ALLOW EXTRA FUNDS FOR ANY OMISSION DEPTHS OF UTILITIES PRIOR TO STARTING WORK OF THIS SECTION. MAKE REQUIRED ADJUSTMENTS TO � 11. CLEANUP: MOUNTED AT 48"ABOVE FINISHED FLOOR ADJACENT TO THE ROOM'S LIGHT SWITCH. WHICH RESULTS FROM A FAILURE TO THOROUGHLY MAKE THE EXAMINATION. CONNECT TO EXISTING UTILITIES. IF INDICATED POINTS OF CONNECTION CANNOT BE MADE TO UTILITIES AS FOUND, > a.UPON COMPLETION OF THE WORK UNDER THIS SECTION, THE CONTRACTOR SHALL REMOVE ALL SURPLUS THE CONTRACTOR SHALL, BEFORE CONTINUING, NOTIFY THE ARCHITECT PRIOR TO INSTALLING ANY WORK WHICH � MATERIALS, EQUIPMENT AND DEBRIS INCIDENTAL TO THIS WORK AND LEAVE THE PREMISES CLEAN AND 18. BEFORE STARTING ANY WORK, THE CONTRACTOR FOR THIS SECTION OF THE WORK SHALL EXAMINE A 5. CODES AND PERMITS: MAY BE AFFECTED. O ORDERLY. COMPLETE SET OF DRAWINGS FOR ALL TRADES, INCLUDING ARCHITECTURAL, STRUCTURAL, HVAC, ELECTRICAL, a.ALL PLUMBING EQUIPMENT, INSTALLATION, ETC., SHALL CONFORM TO THE 2012 INTERNATIONAL PLUMBING � � FIRE PROTECTION AND PLUMBING. DIMENSIONS, SPACE REQUIREMENTS AND POINTS OF CONNECTION TO ALL CODE (IPC), 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)AND ORDINANCES AS INTERPRETED BY 22. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AVAILABLE SPACES FOR INSTALLING THE WORK. 12. MECHANICAL IDENTIFICATION EQUIPMENT SHALL BE VERIFIED, AND ANY MINOR ADJUSTMENTS NECESSARY TO AVOID CONFLICT WITH THE THE TOWN OF VAIL BUILDING DEPARTMENT. � a.EQUIPMENT NAMEPLATES: METAL, WITH DATA ENGRAVED OR STAMPED, FOR PERMANENT ATTACHMENT ON gUILDING STRUCTURE AND THE WORK OF THE OTHER TRADES SHALL BE MADE. CONTRACTOR SHALL NOTIFY b. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS. 23. VALVES SHALL BE NIBCO, JENKINS, WALWORTH, STOCKHAM OR EQUAL. SERVICE PRESSURE SHALL BE � EQUIPMENT. ARCHITECT IMMEDIATELY IF ANY MAJOR CONFLICTS OCCUR. c. COPIES OF ALL PERMITS AND INSPECTION REPORTS SHALL BE SUBMITTED TO THE ARCHITECT. SUITABLE FOR SERVICE INTENDED. � b. PIPE MARKERS: PREPRINTED, COLOR CODED, WITH LETTERING INDICATING SERVICE,AND SHOWING DIRECTION � U OF FLOW. 19. COORDINATE LOCATIONS OF ALL ROOF AND EXTERIOR WALL OPENINGS WITH ALL RELEVANT TRADES,AND 6. AS-BUILTS: 24. PROVIDE HANGERS AND SUPPORTS MEETING THE REQUIREMENTS SPECIFIED IN THE 2009 IPC SECTION 308. O c. VALVE TAGS: STAMPED OR ENGRAVED WITH 1/4" LETTERS FOR PIPING SYSTEM ABBREVIATION AND 1/2" PROVIDE WATERTIGHT FLASHINGS WHEREVER PENETRATIONS OCCUR. EXACT LOCATIONS AND SIZES MAY BE a.CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS-BUILT DOCUMENTS WITH ALL CHANGES NOTED PLUMBERS TAPE AND WIRE ARE NOT ACCEPTABLE. Z W 0 NUMBERS, WITH NUMBERING SCHEME. PROVIDE 5/32" HOLE FOR FASTENER. DEPENDENT UPON EQUIPMENT SELECTIONS; COORDINATE SIZES AND LOCATIONS OF ALL OPENINGS WITH THEREON AT THE COMPLETION OF THE PROJECT AND PRIOR TO FINAL ACCEPTANCE AND PAYMENT. � d. VALVE TAG SCHEDULE: PREPARE A VALVE TAG SCHEDULE TO BE SUBMITTED TO THE MAINTENANCE ENGINEER APPROPRIATE EQUIPMENT REQUIREMENTS. 25. CONTRACTOR SHALL AFFIX A MAINTENANCE LABEL TO ALL EQUIPMENT REQUIRING ROUTINE MAINTENANCE AND � � � � FOR RECORD. 7. GUARANTEE: SHALL PROVIDE THREE COPIES OF MAINTENANCE AND OPERATING MANUALS TO THE OWNER/OPERATOR. � 20. PERMANENT ACCESS TO EQUIPMENT SHALL BE PROVIDED, AND A MINIMUM OF 30"CLEAR WORKING SPACE IN a.CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL LABOR AND MATERIALS ON ALL WORK AGAINST O 13. DUCTWORK: FRONT OF ACCESS PANELS TO THE COMPRESSOR, BLOWER ASSEMBLY AND AIR FILTER SECTION OF THE DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER COMPLETION. 26. CONTRACTOR SHALL ARRANGE FOR AND PAY FOR ALL UTILITY METERS AND UTILITY CONNECTIONS. O a.DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE 2009 IMC AND SMACNA EQUIPMENT SHALL BE PROVIDED BY GENERAL CONTRACTOR. O STANDARDS. 8. SUBMITTALS: 27. ALL PLUMBING LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO THE GREATEST EXTENT � J b. DUCTWORK SHALL BE GALVANIZED STEEL GAUGES TO MEET SMACNA STANDARDS. DUCTWORK SIZES 21. ALL EQUIPMENT SHALL BE SECURELY FASTENED TO THE BUILDING STRUCTURE WITH CODE APPROVED a.CATALOG INFORMATION AND CUTS OF ALL EQUIPMENT AND DEVICES SHALL BE SUBMITTED TO THE ARCHITECT POSSIBLE. ALL LINES NOT CONCEALED SHALL BE SECURED 6"OFF FLOOR AND 3/4" FROM WALL AND CEILINGS � � � O INDICATED ARE FREE CLEAR DIMENSIONS. VIBRATION ISOLATORS. FOR REVIEW(SIX COPIES OF EACH). USING OFFSET BRACKETS. � c. ALL DUCT JOINTS SHALL BE SEALED AIR TIGHT WITH RCD CORP.#6 MASTIC ADHESIVE WITH VERSA GRIP OR MESH. 22. EACH PIECE OF EQUIPMENT AND ALL SYSTEMS SHALL BE ADJUSTED AND RE-ADJUSTED TO INSURE PROPER 9• COORDINATION: 28. AN APPROVED BACKFLOW PREVENTER SHALL BE PROPERLY INSTALLED UPSTREAM OF ANY POTENTIAL HAZARD � .. d.FLEXIBLE DUCT USED FOR CONDITIONED AIR SHALL BE UL APPROVED, VINYL COATED, WIRE REINFORCED FUNCTION OF ALL CONTROLS, MAINTENANCE OF TEMPERATURE,ADEQUACY OF FLOWS AND CAPACITIES, a.THE DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW SCOPE. BETWEEN THE POTABLE WATER SUPPLY AND A SOURCE OF CONTAMINATION. � J FIBERGLASS, WITH MAXIMUM THERMAL CONDUCTIVITY OF 0.30 BTU-IN/HR-FT2-OF AND A MAXIMUM LENGTH OF ELIMINATION OF NOISE AND VIBRATION, AND SHALL BE LEFT IN PROPER OPERATING CONDITION. b. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES TO PROVIDE BEST ARRANGEMENT OF � FIVE FEET. ALL DUCTS, PIPES, CONDUIT, ETC. 29. ALL SINGLE AND THREE PHASE MOTORS, STARTERS AND DISCONNECTS SHALL BE PROVIDED BY THE PLUMBING � Q e. CLOTHES DRYER VENT EXHAUST DUCTWORK SHALL BE ALUMINUM. DUCTWORK SHALL NOT BE CONNECTED OR 23. TEST& BALANCING: CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR. � � INSTALLED WITH SHEET METAL SCREWS OR OTHER FASTENERS THAT WILL OBSTRUCT THE EXHAUST FLOW. a.THE ENTIRE HEATING AND VENTILATING SYSTEM SHALL BE BALANCED BY AN INDEPENDENT CERTIFIED TEST 10. CUTTING AND PATCHING: O > TERMINATE WITH A WALL CAP WITH A BACK DRAFT DAMPER. SCREENS ARE PROHIBITED. REFER TO SECTION AND BALANCE COMPANY. a.ALL CUTTING AND PATCHING REQUIRED OF THE STRUCTURE (NEW OR EXISTING)SHALL BE PROVIDED UNDER � 504 OF THE 2009 IMC FOR MAXIMUM DRYER EXHAUST DUCT LENGTHS. b. 5 COPIES OF THEIR BALANCE REPORTS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW AND APPROVAL. OTHER SECTIONS OF THE WORK. U f. DISHWASHER EXHAUST DUCTWORK SHALL BE ALUMINUM CONSTRUCTION TO MEET SMACNA STANDARDS. c. ALL REQUIRED RE-SHEEVING AND ADJUSTING OF EQUIPMENT SHALL BE MADE BY THE TEST& BALANCE b. PROVIDE NECESSARY REQUIREMENTS TO THE PROJECT SUPERINTENDENT. � SLOPE DUCTWORK BACK TO THE DISHWASHING HOOD. CONTRACTOR. c. X-RAY SLABS PRIOR TO CORING. w g.DUCTWORK SHALL BE SIZED AT A MAXIMUM VELOCITY OF 1,000 FPM/.08" PRESSURE DROP PER 100 FEET. d.ALL FINAL MEASURED CAPACITIES SHALL BE WITHIN 10% OF THOSE INDICATED ON THE PLANS. O O � O PROVIDE FREEZE-STAT DOWNSTREAM � O OF HEATING COIL OR ON CONDENSING ALL THREAD ROD COIL PER MANUFACTURERS � N VIBRATION ISOLATING HANGER(TYP.) INSTRUCTIONS. FLEXIBLE CANVAS CONNECTOR BRASS CLEANOUT PLUG W/COUNTER SUNK HEAD SUC CLEANOUT AND ACCESS 16"f1� CONC. PAD TROWEL AEC PROJECT #: 13063 FLOOR COVER. TOP OF COVER SMOOTH & EDGE � � LINE TO BE FLUSH W/TOP OF CHROME WALLCOVER � FLOOR FINISHED GRADE r � 1" LINED SUPPLY DUCTWORK DATE: ISSUE: AND SCREW 6� � � FAN COIL _ _ _ OH-O6-13 PERMIT I I PLUGGED TEE WITH 1/8 C.I. BEND I I I 1/8 C.I. BEND / CLEAN OUT I I BALANCE OF PIPING LIQ ° SAME AS CLEANOUT C.I. WASTE LINE. - - - - - - � � I - - - � TO GRADE. LGTH TO SUIT. I I FLOOR LINE 1" LINED RETURN � �I D� DRAIN � U STRAINER(TYP.) FLOOR CLEANOUT(FCO) DUCTWORK Drawn By: Checked By: ° ° � ° o � o o v ° v CLEANOUT NOT TO BE LOCATED EXPANSION VALVE o ° o 0 o a � o ° o SHUT-OFF VALVE (TYP.) KBW TOC 0 0 0 0 0 0 o IN CARPETED AREA. PROVIDE MERV-11 FILTER. / WASTE LINE ~ Ya" C.I. BEND UNI-STRUT SUPPORT RAIL INTERNAL DRAIN PAN, CONDENSATE DRAIN MECHANICAL CLEANOUT TO GRADE (COTG) 1/8 BEND IF CLEANOUT OCCURS AT END OF & P-TRAP. OUTLET 1" LOWER THAN INLET LINE. THE MECHANICAL CONTRACTOR SHALL FIELD ESTABLISH THE SPECIFIC FAN COIL UNIT'S COIL PIPING & PLUMBING ARRANGEMENT& FAN ACCESS PRIOR TO SUBMITTING TO THE MANUFACTURER FOR PURCHASING. DETAILS lX. WALL CLEANOUT DIAGRAM NOSCALE CLEANOUT SCHEMATICS D/X FAN COIL UNIT DETAIL SPEC�S NO SCALE NO SCALE NO SCALE • 1 of 2 m COPYRIGHT 2013 ARCHITECTURAL ENGINEERING COtrSULTANTS,INC. O N MINI SPLIT AIR CONDITIONING UNIT SCHEDULE OREQUIVALENT GREASE INTERCEPTOR SCHEDULE OREQUIVALENT � SYSTEM INDOOR UNIT OUTDOOR UNIT ELECTRICAL DATA FLOW DIMESSIONS (IN) OPER. (/� p UNIT MANUFACTURER& UNIT MANUFACTURER& GREASE CAPACITY INLET SIZE OUTLET �+ SERVICE COOL WEIGHT S.P WEIGHT REMARKS SERVICE LOCATION RATE WEIGHT REMARKS � TAG MODEL NO. SEER W(IN) D(IN) H(IN) CFM MCA W(IN) D(IN) H(IN) MCA V/PH/Hz W TAG MODEL NO. (LBS) (GAL.) � H �/ (IN) SIZE (IN) � � � (Cf � (MBH) (LBS) ("WC) (LBS) (GPM) (LBS) � � — � N �--+ U (6 � Ln MITSUBISHI- 618- CU-1: PUY-A30NHA4 � O pp FC-1 PEAD-A30AA4 COOLING 30.0 15.5 43.3 28.88 9.88 73 883 0.40 2.7 37.38 14.19 37.13 163 25.0 208/1 /60 3850 NEOPRENE VIBRATION ISOLATION. GI-1 GT2701-20 FLOOR SINKS PARKING GARAGE 20 40 15 32.375 10 20.75 3 3 102 � � p U ' � N 'N 00 � � �� OR EQUIVALENT O �O Q O M E C H A N I C A L D A M P E R S C H E D U L E P L U M B I N G F I X T U R E C O N N E C T I O N S C H E D U L E v � � �� INLET CFM MAX MAX OPER. � � � � UNIT MANUFACTURER& VELOCITY UNIT COLD HOT � N jC O TAG MODEL NO. SERVICE LOCATION SIZE (FPM) MIN. �(. �D SOUND WT. REMARKS TAG MANUFACTURER& MODEL NO DESCRIPTION WASTE VENT WATER WATER REMARKS � �:� N R5 U (IN) (IN.WC) LVL(NC) (LBS) � � LL- � .� HONEYWELL LV LAVATORY 1-1/2" 1-1/2" 1/2" 1/2" - � � U � MD-1 Zp OUTDOOR AIR ABOVE CEILING 12X5 740 0 250 0.10 25 N/A MOTORIZED DAMPER INTERLOCKED WITH EF-1 � J U �O � WC WATER CLOSET 3" 2" 1/2" - - � Q N � (� PLUMBING FIXTURE SPECIFICATIONS&HARDWARE — °� � �S 00 Q� HS SELECTIONTOBEBYTHEINTERIORDESIGNER. FIXTURE �`NDSINK 1-1/2" 1-1/2" 1/2" 1/2" - � � Q � � (� AI R D EV I C E S C H E D U L E OR EQU IVALENT MS ALLOWANCE NOT TO IXCEED THE ESTABLISHED MpP SINK 2" 1-1/2" 3/4" 3/4" - � �� w �'ti �j BUDGEf. W V W � i UNIT MANUFACTURER& MOUNTING FRAME � TS TRIPLESINK 2" - 3/4" 3/4" - _ � J 2 O � ti TAG MODEL NO. USE LOCATION STYLE �E FINISH SOUND REMARKS (� W � j � LVL(NC) FS FLOORSINK 3" 1-1/2" - - - � (a � � N 1/2"30° SINGLE COORD.W/ CO ZURN ZN1400 CLEAN OUT VARIES - - - - � U � O C A TITUS-25RL SEE PLAN CEILING - 25 STEEL CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS,SIZES,AND SPECIFIED CFMS. DEFLECTION GRILLE ARCH V �� •V � � WCO ZURN Z1441 WALL CLEAN OUT VARIES - - - - � � � � � EXTERIOR 1/2"35° SINGLE COORD.W/ :�' � O � � B TITUS-355FL LOUVER EXTERIOR WALL DEFLECTION GRILLE ARCH 25 ALUMINUM CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS,SIZES,AND SPECIFIED CFMS. COTG ZURN Z1400 CLEAN OUT TO GRADE VARIES - - - LOCATE WITHIN 5'OF THE BUILDING � � � O� � L � a � ~ � AIR CURTAIN SCHEDULE OREQUIVALENT OUTDOOR AIR VENTILATION MECHANICAL/NATURAL � � m ELECTRICAL DATA DIMENSIONS NOISE OPER. NATURAL NATURAL UNIT MANUFACTURER& TOTAL ROOM SIZE CFM/ TOTAL � TAG MODEL NO. LOCATION �E CFM POWER V/PH/Hz FLA � H W LEVEL WT. REMARKS ROOM �SQ.FT.) # PEOPLE PERSON CFM/ SF CFM VENTILATION VENTILATION REMARK � (IN) (IN) (IN) (dBA) (LBS) REQ. (SQ.FT.) AVAILABLE (SQ.FT.) ABOVE FRONT EXISTING EQUIPMENT ON SITE. FURR OUTAPPROX.3"FROM WALL TO AVOID CONFLICT WITH ��� AC-1 E-AIR-EAC1200L EXPOSED - 400 W 120/1 /60 4 46 9 10 - - RETAIL AREA 640 10 7.5 0.12 152 - - 250 CFM MECHANCAL VENTILATION PROVIDED t��"' ru.� DOOR CONDUIT.ANGLE AIR BACK AT DOOR. WSTALL CLOSED DOOR LIMIT SWITCH. �¢�`:��, �� r f+,r t�` �' �r �`r,. Total CFM 152 �'' �`� L `` '` ,�. � SHEET DETAIL NOTES: GENERAL NOTES. MECHANICALVENTILATIONBASEDONIMC2012TABLE403.3 � .� � ��Y^ � 2�s�o � • � 1O EXISTING EXHAUST FAN TO REMAIN. 1. ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE. � -o `',,y�rJ � � � ;= ��?� �Z3 I Z---� � �. ; O2 ROUTE 12x5 DUCT UP THROUGH SLOPED CEILING TO ACCESS 2. ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER ���.��r�S�;�ONpLE<��¢1j`,>;� EXTERIOR WALL AND GRILLE. UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND <{��,���x��,�> DUCTWORK SHALL BE WRAPPED WITH 1.5"THICK INSULATION UNLESS O3 CONNECT GRILLE IN INTERIOR CEILING AND EXTERIOR WALL WITH 12x5 OTHERWISE NOTED. DUCT ABOVE CEILING. PROVIDE ACCESS TO MD-1 AS SHOWN. 3. ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE O4 LOCATE CONDENSING UNIT IN GARAGE BELOW. EXACT LOCATION TO CONICAL TEES. BE DETERMINED ON SITE WITH OWNER,ARCHITECT AND MECHANICAL � � CONTRACTOR. 4. ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES. OFC-1 TO BE MOUNTED ABOVE CEILING IN BATHROOM. PROVIDE 5. ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL � ACCESS IN CEILING. ROUTE 5/"&3/$" REFRIGERANT LINES TO INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY. > CONDENSING UNIT W GARAGE BELOW ACCORDING TO z � MANUFACTURERS RECOMMENDATIONS. LINES TO PASS THROUGH 6. COORDINATE ALL ACCESS PANE� LOCATIONS WITH THE ARCHITECT. O EXISTING HOLE BENEATH MOP SINK. DETERMINE EXACT ROUTING IN � FIELD. 7. ALL WASTE PIPING SHOWN DASHED TO BE LOCATED BENEATH FLOOR. � 8. INSTALL CLEANOUTS AS RE UIRED BY SECTION 708 OF 2012 IPC. � O EXISTING FIXTURE TO REMAIN. ENSURE CONNECTIONS &PIPING Q 4 CU Q INTEGRITY AND REPLACE IF NECESSARY. � � � U O7 CONNECT%2' CW,%2" HW, 1 %2"W& 1 %"V TO HS. _ _ O N � TS g nC.�n � � � 3 �� 3 � 1 �� - � O8 CONNECT /4 CW, /4' HW, 2"W& 1 / V TO MS. � _ 883-R A � �� O � 12x22 �J o WCO6 � � � O9 C ONNE CT%4" CW,3�q�� HW&2"W T O T S. C ONNE CT W T O F S VIA � INDIRECT CONNECTION. FC APPROXIMATE LOCATION OF 5" HOLE TO GARAGE FOR REFRIGERANT LINES. CONFIRM �2 �G � �� 1 O E EF � 5 � S I Z E R E Q U I R E M E N T W I T H M E C H A N I C A L C O N T R A C T O R P R I O R T O D R I L L I N G O R E N L A R G I N G. �V O 12 � � F S 1 0 O O � — O O 1 0 C O N N E C T 2"W& 1 /"V T O F S. � 3„W w J ���° � MS O8 I 2��W O 11 GI-1 TO BE LOCATED IN GARAGE. EXACT LOCATION TO BE � _ _ (EX) 12x12 _ C- � � � DETERMINED ON SITE. CONNECT 3"W AT ENTRY& EXIT. — � � �V� V I � 12 CONTINUE W&V TO EXISTING WASTE&VENT LINES. ENSURE , I �q. UNDER- � � YOi, EXISTING PIPE CAN HANDLE ADDITIONAL LOAD. n�n I I N N II �I � 4 - - — � FRIG COUNTER � � J n ^ I I FRIG � 13 ROUTE 1 %z'W& 1 %"V TO EXISTING LV. CONNECT W PRIOR TO � FS�1f 0 � � Q PENETRATING FLOOR, AND V PRIOR TO PENETRATING CEILING. 2��W � \ APPROXIMATE LOCATIONS OF I I I O / 14 ROUTE 2"W FROM YOGURT STAND TO FS AND CONNECT VIA INDIRECT EXISTING DUCTS AND DIFFUSERS 13 � 1 Yz"W&V � CONNECTION. I I V � V 15 EQUIPMENT ALREADY ON SITE. INSTALL APPROXIMATELY 3" OFF WALL P.o.s. 9' I I � � P.O.S. 9'CASE � W O O TO AVOID CONDUIT. ANGLE AIR BACK TOWARDS DOOR. � I � I a O 16 EXISTING DIFFUSERS WILL PRODUCE NOISE LEVEL OF 50 N.C. I I � O O ; � O COORDINATE WITH OWNER IF NOISE WILL BE AN ISSUE AND REPLACE _ � I (E)8'QJ (TYP. OF 3) � � � _ � O WITH LARGER DIFFUSER. � CONFIRM IN FIELD � C HS O J�� � 17 EXISTING 250 CFM EXHAUST FAN IN HOOD TO SERVE VENTILATION � L�Dp -�� V N PURPOSES. 16 (EX) �2x4S � 16 (EX) �ZX4S 292x4 (EX) 16 � 4 J`-'� � _ � � Q SEQUENCE OF OPERATIONS: O O � HEATING: i i AEC PROJECT #: 13063 HEATING SHALL BE CONTROLLED BY A WALL MOUNTED THERMOSTAT. UPON � � A CALL FOR HEAT THE EXISTING BASEBOARD HEATERS SHALL ACTIVATE 17 � � DATE: ISSUE: AND REMAIN ON UNTIL THE CALL IS SATISFIED. — � w i U I - - -J U COOLING: a i i a COOLING SHALL BE CONTROLLED BY THE MANUFACTURER'S PROVIDED a �\ i � a REMOTE CONTROL UNIT. UPON A CALL FOR COOLING THE FAN COIL AND �n � � x � .'. ;..AY\ I I DISPLAY � � CONDENSING UNIT SHALL OPERATE UNTIL THE CALL IS SATISFIED. N 250-OA � � z INTERLOCK WITH (E) BASEBOARDS AND BLOCK THEM WHEN IN COOLING / 12x6 A i i �, MODE. AC �5 � � i i i i VENTILATION: ' 12x12 ACCESS PANEL VENTILATION IS PROVIDED BY A 250 CFM (E) EXHAUST HOOD INTERLOCKED 12x5 � i IEXISTING BASEBOARD EXISTING BASEBOARD WITH A MECHANICAL DAMPER ON AN OUTDOOR AIR DUCT. DURING Drawn By: Checked By: OCCUPIED HOURS THE HOOD SHALL BE SWITCHED ON TO EXHAUST AIR AND MD THE INTERLOCKED DAMPER SHALL OPEN TO ALLOW OUTSIDE AIR TO ENTER B 250-EX B 250-OA 1 � KBW TOC THE SPACE. 10x6 1 10x6 I �- - - - - - - - - - - - - - - - - - - - - - - - - - - - - � � � MECHANICAL & PLUMB ING NORTH NORTH PLAN & MECHANICAL PLAN PLUMBING PLAN SCHEDULES S CALE 1/4" = 1'-0" SCALE: 1/4"= 1'0" SCALE: 1/4"= 1'0" • 2 Of 2 m COPYRIGHT 2013 ARCHITECTURAL ENGINEERING COtrSULTANTS,INC. TYPICAL8�o�� CEILING ELECTRICAL LEGEND ELECTRICAL SPECIFICATIONS ° N � (NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT) 14. ELECTRICAL DEVICES L. All cable hangers shall be no more than 48" apart. Contractor shall be � g �� � /� A. Convenience receptacles will be 20 amp, commercial grade familiar and install in accordance with all applicable codes and standards, � O RECESSED OR SURFACE DOWNLIGHT ABBREVIATIONS /1. G e n e ra I Req u i re m e nts decora style. Finish per owner or architect. including NEC, EIA/TIA 568,569 and 606, and federal, state and local codes. .�+ � �--I WALL MOUNTED LIGHT FIXTURE AC -ABOVE COUNTER Care must be taken to ensure cables are not kinked, bent beyond limit, � cA � � � AFF -ABOVE FINISHED FLOOR �� SCOPE: Furnish all materials and labor required to execute this work B. Light switches will be 20 amp, commercial grade, overloaded, over-cinched, crushed, improperly untwisted, etc. (�j � — L N Aa RECESSED FLUOR.LIGHT FIXTURE U (LS O AFG -ABOVE FINISHED GRADE as indicated on drawing and as specified, as necessary to complete the decora style. Finish per owner or architect. �--� � O � AHJ -AUTHORITY HAVING JURISDICTION Aa SURFACE FLUOR.LIGHT FIXTURE contract. Electrical work shall include, but not limited to, these major M. No exposed wiring will be accepted unless approved in writing by the � � � U ' M A I N C I R C U I T B R E A K E R& AL -ALUMINUM C. Dimming switches will be a minimum of 600w or as noted. � �N pp FIXTURE DESIGNATIONS: CU -COPPER i tems: Provide decora style, finish per owner or architect. engineer. Cabling shall be in the wall, above the ceiling or where exposed, (n � � �� � BRANCH CIRCUIT BREAKERS UPPER CASE-FIXTURE TYPE EC -ELECTRICAL CONTRACTOR enclosed within cable trays, raceways or conduit, as specified. � � ti LOWER CASE-SWITCH DESIGNATION EM -EMERGENCY A. Com lete wirin s stem for new li htin and ower as shown, D. All mountin hei hts will conform to ADA uidelines. T ical rece tacle � `'— � ' MAXIMUM MOUNTING HEIGHT P 9 Y 9 9 P 9 9 9 YP P Q � O � O GC -GENERAL CONTRACTOR IS 79", MINIMUM IS 18��. SHADING ON FIXTURE INDICATES EMERG.BATTERY BACKUP GND -GROUND including new panelboards, new conduits, new wires, new wiring heights will be +18"AFF and switch heights will be +46"AFF N. All cabling shall be bundled and properly secured and terminated. �cn � Q ti GFI -GROUND FAULT INTERRUPTER devices, new control devices, etc.for a complete lighting and unless noted otherwise. � N � � �� FLUORESCENT STRIP FIXTURE MC -MECHANICAL CONTRACTOR Q � � � �❑� O �� TRACK LIGHT AS NOTED OR SCHEDULED NIC -NOT IN CONTRACT and power system. E. Provide GFI type receptacles at kitchens, bathrooms, O. The warranty set forth for this system shall consist of a full three(3)years � � X Q c4 NL -NIGHT LIGHT ara es, exterior etc. as re uired b code. from the date of ro ect com letion. The contractor warrants the s stem to be ��'= N � U � WALL WASHER a. Com lete feeder s installation as re uired for new and/or g g p y p � p y � C . NTS -NOT TO SCALE P � ) � q � � � _ � 0--�0 pparatus as shown on single line diagram and F. Provide tamper proof receptacles at all residential free of defects of workmanship or products and will inspect and repair the '� � � � co -� POLE-MOUNTED FIXTURE PC -PLUMBING CONTRACTOR electrical a — O REF -REFERENCE system during this warranty period at no additional cost to the owner. The � •� � � POST(BOLLARD)FIXTURE drawings. areas as required by code. � U � UG -UNDERGROUND warranty period shall begin at the point of system acceptance or beneficial U �� � � c- � STEP LIGHT UNO -UNLESS NOTED OTHERWISE b. Complete branch circuit wiring required for the connection of 15. SUPPORT use, whichever comes later. � 'J Q N N U 0 UTP -UNSHIELDED TWISTED PAIR � � � � � CEILING OR WALL MOUNTED EXIT LIGHT � �LS �,� WP -WEATHER PROOF emergency lighting and exit signs to existing emergency stand A. Support all electrical equipment independent of accessible ceilings as � �S o0 N ` � EMERGENCY BATTERY LIGHTS XFMR -TRANSFORMER by power system. required by NEC. � ���0 TV � DUPLEX RECEPTACLE @ 18"UNLESS NOTED +18" -MOUNTING HEIGHT TO CENTERLINE (� Q � QQ � OF DEVICE AFF OR AFG � 'L W �'� � � DOUBLE DUPLEX RECEPTACLE @ 18"UNLESS NOTED 2. Complete provision, installation and connection of lighting fixtures, 16. ELECTRICAL BOXES LL� V w � O � � QQ FLUSH FLOOR DUPLEX RECEPTACLE FIRE ALARM SYSTEM exit signs and lamps as specified and as shown on drawings. A. At fire rated wall space electrical boxes at opposite sides of the wall � � � � � � FINISHED FLOOR � SPECIAL OUTLET AS NOTED �FACP FIRE ALARM CONTROL PANEL 3. Fire alarm system will be by electrical contractor. no less than 24�� horizontal distance. � w +., � � � DUPLEX RECEPTACLE HALF-SWITCHED @ 18"UNLESS NOTED ANN FIRE ALARM ANNUNCIATOR PANEL 4. Complete connection of HVAC/Plumbing motor(s),water heater(s), B. When phone, TV& power receptacles are shown on plan next to each other. � � .� � � � POP-UP RECEPTACLE � FIRE ALARM PULL STATION Locate respective receptacles next to each other on site with no more �i (� � � � equipment, etc. furnish by mechanical - refer to both electrical and � TELE-POWER POLE ❑Q ALARM HORN OR SPEAKER than 1�� seperating cover plates. V �C .V � � and mechanical drawin for sco e and work and additinal infor- ^, � TY P I A L D E V I C E � MULTI-OUTLET PLUG STRIP �� COMBINATION HORN/STROBE OR SPEAKER/STROBE g p 17. METERING }+ U O � � mation. ._ � J� J� J�--I JUNCTION BOX IN FLOOR,CEILING OR IN WALL •H THERMAL HEAT DETECTOR A. EC shall coordinate whether or not meters require lever bypass with local � � � � — M O U N T I N G H E I G H TS � � COMPUTER/TELEPHONE OUTLET IN FLOOR OR WALL •I SMOKE/IONIZATION DETECTOR 5. Provide grounding and bonding Facilities. utility and provide all meters with a lever bypass when required. L � Q � � I--B TELEVISION OUTLET •P PHOTOELECTRIC SMOKE DETECTOR p0 TELEPNONE BACKBOARD •H/P HEAT/PHOTOELECTRIC SMOKE DETECTOR 6. Complete all electrical demolition as required. B. C at 6 W i ri n g Req u i re m e n ts � � NOT TO SCALE CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING �S �R DUCT DETECTOR NOTES: m � CIRCUIT HOMERUN �F SPRINKLER SYSTEM FLOW SWITCH 7. Core drilling and patching of existing building structure required for 1. HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX electrical work. Core drillin shall follow Buildin Standard rocedures A. The cabling for voice and data must be continuous, home run, non-spliced, � UNLESS NOTED OTHERWISE. - - - CONDUIT RUN BELOW FLOOR OR GRADE B+ SPRINKLER SYSTEM TAMPER SWITCH g g p 500 Mhz or better category 6, 4 pair UTP as applicable. Acceptable � ] CONDUIT STUB-UP-CAP&MARK �- STROBE and contractor shall have written approvals from building owner prior 2. DEVICES ABOVE DOORS SHALL BE CENTERED BETWEEN TOP ` to start of an work. manufacturers include: Berk-Tek, Belden, Lucent or equivalent. OF DOOR TRIM AND CEILING LINE. $ LIGHT SWITCH AT 46"UNLESS NOTED 0 SMOKE/FIRE DAMPER CONNECTION Y 3. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS 2=B POLE SWITCH �=� REMOTE INDICATOR LIGHT 8. Test of entire system and work. B. Data cable will be colored blue. Voice cable will be colored white. �,, AND NOTED ON ELECTRICAL FLOOR PLANS SHALL GOVERN 3=3-WAY SWITCH �' � � ��,�� ��:� SECURITY SYSTEM t� ctL� - �� '�•. 4=4-WAY SWITCH 9. O eratin Maintenance and identification instructions manuals, if C. The terminations at the station locations must be Cate o 6, T568B AT&T ti�` � OVER THOSE SHOWN ABOVE. p 9� 9 ►Y � ) M=MOTION-OPERATED SWITCH DC CONTACT DOOR SWITCH IN JAMB OR HINGE ' � 4. FOR CEILING HEIGHTS HIGHER THAN 7 2 , INSTALL FIRE ALARM K=KEY-OPERATED SWITCH � any. modular RJ-45, 8 pin, 8 conductor, Hubbell, Leviton, or lucent or equivalent -- , � a NOTIFICATION AUDIO AND VISUAL APPLIANCES AT 80��AFF TO=THERMAL OVERLOAD SWITCH P� INTRUSION MOTION DETECTOR AS SPECIFIED,CORRIDOR/ROOM jacks, match faceplates to power, color coded for voice and data, Y11atCh t0 �� ' � OTHERWISE INSTALL AT 6" BELOW CEILING. P=SWITCH WITH PILOT LIGHT C OR R 10. PERMITS AND FEES: Obtain and pay for all necessary permits, inspec- cable. Outlets will be securely held in place. �r 4 2984d � � � ❑D DIMMER SWITCH W/WATTAGE tions, examinations and fees or charges necessary for execution and � 5. MOUNTING HEIGHTS PER IBC 2009 AND ADA CODES ❑K KEY-OPERATED ACCESS SWITCH � `� r�� �'' �V com letion of electrical work. � Z3 /�--� ;. �� SURVEILLANCE CAMERA p D. Wall mounted patch panels will be provided. "� �,� � ❑M CEILING MOUNT MOTION SENSOR � � 0 PUSHBUTTON CONTROL STATION �'�l��S��� �����}�����ys'' Pc PHOTOELECTRIC CELL DISTRIBUTION EQUIPMENT SYMBOLS 11. REGULATIONS AND CODES: E. All cables will be labeled with self-laminating labels at each cable end, at each Ts TIME SWITCH —�— DISCONNECT SWITCH A. Applicable codes: National Electric Code (2011) patch panel location, and each wall/floor faceplate that has wiring installed. OT THERMOSTAT AT 60��UNLESS NOTED �— FUSES Conform to the prevailing edition and amendments thereto of the Coordinate numbering scheme with owner. eDIVISION 15 EQUIPMENT ^ CIRCUIT BREAKER Town of Vail Electrical Code, pertinent NFPA publications F. Provide plenum rated cable when required by article NEC 300-22. 0 FOOD SERVICE EQUIPMENT —�— CURRENT TRANSFORMER and to the requirements of Federal, State or other City agencies �v TRANSFORMER having jurisdiction. COMMUNICATION SYSTEM �wv� G. All cable above the ceiling must be tied and properly supported with � � M� METER 12. SHOP DRAWINGS AND SUBMITTAL: independent hangers. Cable "draped" across ceiling tiles is unacceptable. In �S SQ-I SPEAKER IN CEILING OR WALL � MAGNETIC MOTOR STARTER the case of��hard�� drywall ceilings, adequate support shall be accomplished V�-I VOLUME CONTROL AT 60"UNLESS NOTED A. Contractor shall submit shop drawings for engineer review and approval. � ❑� DISCONNECT SWITCH where reasonably possible. � O �M M MICROPHONE OUTLET IN FLOOR BOX OR WALL B. Shop draW;ng Subm;tta, Sha„ ;n�,Ude: G E N E RAL N OT E S AL L S H E ETS � � PANELBOARD OR LOAD CENTER,FLUSH OR SURFACE MOUNTED OC --I CALL-IN SWITCH � SWITCHBOARD,MOTOR CONTROL CENTER OR DISTRIBUTION BOARD H. Route cables so as not to exceed 90 meters in length. Bidder will identify any � � �B PROGRAM BELL 1. Lighting fixtures. cable runs exceeding 90 meters and provide solution to meet the 90 meter ❑T TRANSFORMER 2. Panelboard(s). THE ELECTRICAL CONTRACTOR WILL PROVIDE A WALK THROUGH WITH THE � � �I INTERCOM i GROUND requirement. � CLOCK �� OWNER/ARCHITECT PRIOR TO FINAL ROUGHIN AS FOLLOWS: � CIRCUIT BREAKER 13. CONDUIT AND WIRE: I. All wiring shall be protected from moving mechanical or physical contacts. • CONFIRM ALL LOCATIONS FOR LIGHT SWITCHES; ADD THREE WAYS IF � �A AMPLIFIER M MOTOR OUTLET A. CONDUCTOR SIZES AND TYPES: For sizes#1/0 AWG and lar er, use FOUND NECESSARY. � O 9 Cabling shall be free from tension at both ends, as well as through out the Q ars AUTOMATIC TRANSFER SWITCH coppper THW or aluminum XHHW. For sizes#1 AWG and smaller, use only length of the run. Splices and bridge taps with cabling are strictly prohibited. • REVIEW RECEPTACLE LOCATIONS; MOVE AS REQUIRED. PROVIDE � copper wire with 600V insulation, types TW, THHN, or THW-stranded in Wiring is to be run in cable tray and conduit where specified. UNIT PRICING IF ADDITIONAL RECEPTACLES ARE REQUIRED. V sizes#8 and larger, solid in sizes#10 and smaller. Control wiring shall be#14, . REVIEW RECEPTACLE LOCATIONS AT COUNTERS AND CONFIRM IF O stranded. Use type THHN for wires entering or passing through fluorescent J. All connections of twisted wiring shall be made in such a way as to minimize THOSE RECEPTACLES SHOULD BE ABOVE COUNTER OR BELOW. MOVE � � Q 1. WALL ASSEMBLY-THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY lighting fixtures. All motors shall be wired with copper conductors only. the extent in which each twisted pair is unraveled at the point of its physical AS REQUIRED. Q SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL B. MC cable permitted per local codes. Run hard pipe from panel to local termination. No more than .5 inches of exposed untwisted pairs shall be IN GENERAL CONFIRM POWER AND LIGHTING REQUIREMENTS. THE � � Q U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND junction box, and run MC cable from junction box to device. present at these locations. ELECTRICIAN SHOULD BE PREPARED TO REWORK SOME DEVICE LOCATIONS. � 1 A � SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: SIGNIFICANT REWORK SHOULD BE FLAGGED AND UNIT PRICING PROVIDED � 3 K. Cable bends shall be no less than eight times the cable diameter or 1.00". AND WRITTEN AUTHORIZATION FOR ADDITIONAL COSTS APPROVED PRIOR O � A. STUDS -WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 HR FIRE RATED Cables are to be kept a minimum of 6"from power lines, electric motors, TO PROCEEDING. � J ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 fluorescent fixtures or heat generating devices. O MM) LUMBER SPACED 16 IN. (406 MM) OC WITH NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER END PLATES � � ;M�:��%= �`'s�-�£�• AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM)WIDE BY 1-3/8 IN. (35 MM) DEEP ♦ 1 CHANNELS SPACED MAX 24 IN. (610 MM) OC. LJ B. GYPSUM BOARD* - NOM 1/2 OR 5/8 IN. (13 OR 16 MM)THICK, 4 FT. (122 CM)WIDE WITH SQUARE � OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER � � J TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES � � DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 26 IN. (660 MM). � � � 2. THROUGH PENETRANT- ONE CONDUIT INSTALLED EITHER CONCENTRICALLY OR ROUTE WIRE AT CEILING PARALLEL OR > ,..,., ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR PERPENDICULAR TO STRUCTURE. SECURE � `'�'}Y`"� ;�� TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM) (POINT CONTACT)TO MAX 2 IN. (51 TO STRUCTURE AT 4' INTERVALS OR LESS. U y::.r� a.s:y;y:,='°:: MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. PANEL � THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: RM w 1 B A. CONDUIT- NOM 6 IN. (152 MM) DIAM (OR SMALLER)STEEL CONDUIT OR NOM 4 IN. (102 MM) DIAM STUB UP TO ABOVE (OR SMALLER)STEEL ELECTRICAL METALLIC TUBING ACCESSIBLE CEILNG � O 3. FILL,VOID OR CAVITY MATERIAL* - CAULK OR SEALANT - MIN 5/8. 1-1/4,1-7/8 AND 2-1/2 IN. +80:AFF � (16, 32, 48 AND 64 MM)THICKNESS OF CAULK FOR 1, 2, 3 AND 4 HR RATED ASSEMBLIES, � O RESPECTIVELY, APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. MIN 1/4 IN. (6 MM) <10K AIC � DIAM BEAD OF CAULK APPLIED TO GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACT STRUCTURED CABLE � LOCATION ON BOTH SIDES OF WALL. DISTRIBUTION PANEL THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING (4#1 CU, 1 #6 CUG)2"C Max Pipe or Conduit F Rating T Rating OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS SHOWN IN THE FOLLOWING TABLE. +80"AFF OR(4#1/0 AL, 1 #4 ALG)2"C Diar� in. Cmm) Hr Hr THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE (2#CAT 6) 3/4"C, PLENUM RATED WIRE 1 C25) 1 or 2 0+, 1 or 2 PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, WHEN REQUIRED NEW WORK IS CLOUDED, 1 C25) 3 or 4 3 or 4 AS TABULATED TO THE LEFT. f REST �s Ex�sT�N�. AEC PROJECT #: 13063 #6 CU G 4 C102) 1 or 2 0 3M COMPANY-CP 25WB+ CAULK OR FB-3000 WT SEALANT, (PULLWIRE)4"C MDC TOTAL LOAD 6 C152) 3 or 4 0 P 430 AMPS X 1.25 + HOLY CROSS DATE: ISSUE: *BEARING THE UL CLASSIFICATION MARKING (1) RJ-11 & (1) RJ-45 PANEL RM DEMAND METER#95650 12 C305) 1 or 2 0 MAIN TELE/DATA IN SINGLE GANG = 643 AMPS HIGHEST 08-06-13 PERMIT ROOM ,�I BOX AT 18"AFF UNO DEMAND JAN PROVIDE PRIVATE METERING DEVICE P E N ET RAT I O N T H RO U G H A F I R E—RAT E D WAL L T E L E P H O N E O N E� COLD WATER PIPE T E L E P H O N E/ 2013 155KW OR MATCH TO EXISTING AT THIS MDC. 430 AMPS. NOTTOSCALE LINE DIAGRAM COMPUTER ROUGHIN M � — NO SCALE 125/3 59,900 AIC 45,000 AIC � � � Drawn By: Checked By: EXISTING I I I SOH AEC uT���TY _ _ ELECTRICAL TRANSFORMER MAIN DISTRIBUTION CENTER "MDC" PAD MOUNTED SPECS AND 2000A, 120/208V, 3P, 4W 42kAIC ONELINES ELECTRICAL ONE—LINE DIAGRAM NO SCALE NOTE: PROVIDE SHORT CIRCUIT BRACING TO MEET FAULT CURRENT LEVELS NOTED ON ONE-LINE AS "X AFC", WHERE X IS IN AMPS. SERIES RATED CIRCUIT BREAKER COMBINATIONS ACCEPTABLE; SUBMIT MANUFACTURER'S SERIES • RATINGS WITH SHOP DRAWING REVIEW. 1 of 2 OO COFYRIGHT 2013 ARCHITECTURAL ENGWEERING CONSULTANTS, INC. 0 PANEL RM � � PROJECT:ROCKYMOUNTAIN CHOCOLATE FACTORY ENGINEER: SOH �0 G E N E RAL N OTES. PROJECT#: 13063 VOLTAGE: 120/208V,3P,4W (n MOUNTING:RECESS MAINS: 125A MLO � � TYPE:SQ D QO OR EQUAL AIC: 10K � � tn � � 1. EXISTING LIGHTING AND SHOW WINDOW POWER TO REMAIN IN PLACE. PHASE PHASE � U (Cf O N 2. REUSE EXISTING RECEPTACLES AS FIELD CONDITIONS PERMIT, REVIEW DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION �- �� � O o�0 WITH OWNER. � � •� U � 3. PROVIDE GFI TYPE RECEPTACLES AT ALL AREAS CONSIDERED AS LIGHTING EXISTING 1500 20 1 1 2 1 20 1080 RECEPTACLE EXISTING � (n tn �� KITCHEN AREAS BY CODE. LIGHTING EXISTING 1500 20 1 3 4 1 20 500 BATHROOM EF EXISTING � � � O � RECEPTACLE EXISTING 1080 20 1 5 6 1 20 1080 RECEPTACLE EXISTING O �� Q � FREEZER 1200 20 1 7 8 1 20 1200 APPLE CASE � FREEZER 1200 20 1 9 10 1 20 1200 ICE CREAM � � � d' � UC REFRIGERATOR 600 20 1 11 12 1 20 180 POS � � N N � 0 SODA 1200 20 1 13 14 1 20 180 POS � C � � � _ RECEPTACLE NEXTTO SOD 180 20 1 15 16 1 20 1200 CANDYCASE �L— � � � — RECEPTACLES EASTCTR(2) 360 20 1 17 18 1 20 1200 CANDYCASE � � U .� ESPRESSO 1400 20 1 19 20 0 SPACE � J Q N N > RECEPTACLES EAST CTR(2) 360 20 1 21 22 2 40 1925 AIR CONDITIONING � p�f � � � � SPACE 0 23 24 1925 " i- � YOGURT MACHINE 2600 30 2 25 26 1 20 540 RECEPTACLES WEST(3) � V 0 � � � " 2600 27 28 1 20 540 RECEPTACLES WEST(3) � � W � ti � DECORATIVE HOOD 1000 20 2 29 30 1 20 400 AIR CURTAIN � J 2 O " 1000 31 32 0 SPACE � w � � � � FUDGE COOKER 3120 40 2 33 34 0 SPACE 3120 35 36 0 SPACE � � � � Qj ELECTRIC STOVE 4800 40 2 37 38 0 SPACE � U � O C 4800 39 40 0 SPACE V � ,� O � 0 41 42 0 � � O � Q N � � C � � LOAD CALCULATION SUMMARY RELOCATE EXISTING BRANCH CIRCUITS FROM EXISTING PANEL TO NEW PANEL AS REQUIRED. U � Q Op � L � CALCULATED POWER FACTOR: Q � 0.98 X O CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS m LIGHTING/CONTINUOUS 3000 8 3750 10 Q RECEPTACLES 5580 15 5580 15 � MECHANICAL 4750 15 5712.5 19 KfTCHEN 33440 93 21736 60 TOTAL 46770 132 36779 105 O� � �����`}���� ��'��� " ' �' `'"- -� a 4 ��g�� � � '-� � �? � � .A����Z�,,/,��cti:'�.. �r FS`S'a���t�}`', � � � � � � RM-22,24 PROVIDE 120V INTERLOCK FROM � M BATHROOM EXHAUST FAN TO CONDENSING MOTORIZED DAMPER. � UNIT AT GARAGE � PROVIDE 40A2P CONFIRM NON FIRE RATED WALL, Q HOMERUN, (3#8 , IF REQUIRED PROVIDE SURFACE � #10G 1"C. MOUNTED PANEL. � ) O Z Wo Q �NK SINK SINK � � � � PAN EL n/ RM � L.L M To O W J RM-25,27 - RM-7 RM-9 RM-11 � � O 30A2P RM-13 U AC � � AC A � � J RM-15 � Q RM-17 RM-26 � � RM-12 RM-16 � RM-1 Q U A� U w RM-19 � O � RM-10 � SPRESSO O � :w � V cv � �� RM-18 �� �. RM-30,32 RM-28 40A2P AC RM-8 RM-34,s6 ELECTRIC �� AEC PROJECT #: 13063 40A2P OVEN RM-21 ��`" DATE: ISSUE: FUDGE RM-22,24 COOKPOT M 08-06-13 PERMIT DECORATIVE AC HOOD 20A2P HOMERUN, (3#12 , #12G)1"C. VERIFY AC ELECTRICAL REQUIREMENTS , Drawn By: Checked By: AIR CURTAIN SOH AEC RECEPTACLE ABOVEDOOR � � RM-3° ELECTRICAL NORTH PLAN ELECTRICAL PLAN SCALE: SCALE 1/4" = 1'-0" • 2 of 2 �O COPYRIGHT 2013 ARCHITE�TURAL ENGWEERING CONSULTANTS, INC. 0 M EC HAN I CAL S P EC I F I CATI O N S. h. EACH MECHANICAL VENTILATION SYSTEM (SUPPLY AND/OR EXHAUST)SHALL BE EQUIPPED WITH A MEANS OF 24. FINAL LOCATION OF GRILLES, REGISTERS & DIFFUSERS SHALL BE PER THE ARCHITECTURAL PLANS, ELEVATIONS 11. CLEANUP: CO SHUT-OFF WHEN VENTILATION IS NOT REQUIRED,AND BACKDRAFT DAMPERS WHICH CAN BE CLOSED ON FAN OR AS PER FIELD REQUIREMENTS. a.UPON COMPLETION OF THE WORK UNDER THIS SECTION, THE CONTRACTOR SHALL REMOVE ALL SURPLUS � SHUTDOWN SHALL BE PROVIDED FOR AIR INTAKES AND/OR DISCHARGES. MATERIA�S, EQUIPMENT AND DEBRIS INCIDENTAL TO THIS WORK AND LEAVE THE PREMISES CLEAN AND 1. GENERAL: i. CLEAN OUT ALL DUCTS PRIOR TO SUPPLY AND RETURN GRILLE INSTALLATION 25. THE GENERAL CONTRACTOR SHALL FURNISH & INSTALL ALL OF THE REQUIRED ACCESS PANELS IN THE ORDERLY. +�-+ � a.FURNISH ALL LABOR, SUPERVISION, MATERIALS, EQUIPMENT AND FACILITIES NECESSARY TO FURNISH, j. DOUBLE THICKNESS TURNING VANES SHALL BE USED ON ALL DUCT TURNS OF 90°. DRYWALL CEILINGS TO GAIN SERVICE ACCESS TO THE EQUIPMENT. EQUIPMENT WITH MANUFACTURER MANDATED � t� N � � FABRICATE, DELIVER, STORE AND INSTALL ALL WORK NOTED ON THE DRAWINGS AND/OR SPECIFIED HEREIN. SERVICE REQUIREMENTS INSTALLED WITHIN CRAWLSPACES MUST BE A MAXIMUM OF 20 FEET FROM AN ACCESS 12. PLUMBING IDENTIFICATION (� V � p N b. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL WORK NECESSARY TO MAKE A COMPLETE SYSTEM 14. REFRIGERANT PIPING: PANEL. a.EQUIPMENT NAMEPLATES: METAL, WITH DATA ENGRAVED OR STAMPED, FOR PERMANENT ATTACHMENT ON � C p � WHETHER OR NOT SUCH DETAILS ARE MENTIONED IN THESE SPECIFICATIONS OR SHOWN ON THE PLANS, BUT a.REFRIGERANT LINE SETS SHALL BE FURNISHED BY THE CONDENSING UNIT MANUFACTURER AND BE EQUIPMENT. � � � U � WHICH ARE OBVIOUSLY NECESSARY TO MAKE A COMPLETE SYSTEM, EXCEPTING ONLY THOSE PORTIONS THAT PRE-INSULATED. 26. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S INSTALLATION, OPERATION & b. PIPE MARKERS: PREPRINTED, COLOR CODED, WITH LETTERING INDICATING SERVICE,AND SHOWING DIRECTION U� � � °� ARE SPECIFICALLY MENTIONED HEREIN OR PLAINLY MARKED ON THE ACCOMPANYING DRAWINGS AS BEING b. REFRIGERANT PIPING CONNECTIONS SHALL BE BRAZED WITH 15% SILL FLOSS. PURGE PIPING WITH NITROGEN MAINTENANCE MANUAL'S RECOMMENDATIONS ESPECIALLY FOR SERVICE CLEARANCES. OF FLOW. � � N p ti INSTALLED UNDER ANOTHER SECTION OF THE SPECIFICATIONS. WHILE BRAZING. c. VALVE TAGS: STAMPED OR ENGRAVED WITH 1/4" LETTERS FOR PIPING SYSTEM ABBREVIATION AND 1/2" O ,�O a O c. PROVIDE HANGERS, SUPPORTS AND INSULATION SADDLES AS REQUIRED AND PER ANSI REQUIREMENTS. 27. FILTERS: NUMBERS, WITH NUMBERING SCHEME. PROVIDE 5/32" HOLE FOR FASTENER. r , 2.WORKMANSHIP: PLUMBERS TAPE AND WIRE ARE NOT ACCEPTABLE. a.SHALL BE UL RATED AND APPROVED. d. VALVE TAG SCHEDULE: PREPARE A VALVE TAG SCHEDULE TO BE SUBMITTED TO THE MAINTENANCE ENGINEER v � � d' � � a.T H E W O R K S H A L L B E A C C O M P L I S H E D I N A T H O R O U G H A N D W O R K M A N-L I K E M A N N E R S A T I S F A C T O R Y T O A N D d.REFRIGERANT PIPING INDICATED IS SCHEMATIC ONLY. SIZE PIPING AND DESIGN THE ACTUAL PIPING LAYOUT, b. P R E S S UR E D R O P S S HA L L N O T E X C E E D .1 0"S T A T I C P R E S S U R E. FOR RECORD. � � � X O MEETING THE APPROVAL OF THE OWNER AND ARCHITECT. INCLUDING OIL TRAPS, DOUBLE RISERS, SPECIALTIES, AND PIPE AND TUBE SIZES,TO ENSURE PROPER � ��' N (i3 U � � � � - OPERATION AND COMPLIANCE WITH WARRANTIES OF CONNECTED EQUIPMENT. 28. ELECTRICAL CONNECTIONS: 13. PIPE INSULATION: �L � N ''"' 3.MATERIALS: e. EVACUATE THE ENTIRE REFRIGERANT SYSTEM WITH A VACUUM PUMP TO A VACUUM OF 500 MICROMETER FOR a.UNLESS OTHERWISE INDICATED ALL MAGNETIC MOTOR STARTERS,THERMAL OVERLOADS, LOW VOLTAGE a.DOMESTIC WATER PIPING INSULATION SHALL HAVE A THERMAL CONDUCTIVITY LESS THAN OR EQUAL TO 0.27 N � U � � a. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND THE BEST OF THEIR RESPECTIVE KIND, FREE FROM ALL A PERIOD OF 12 HOURS PRIOR TO CHARGING. THERMOSTATS, CONTROL RELAYS, CONTROL TRANSFORMERS AND SOLENOID VALVES SHALL BY FURNISHED BTU-IN/HR-FT2-OF. N J V � N � DEFECTS AND OF THE MAKE AND QUALITY SPECIFIED. BY THE MECHANICAL CONTRACTOR. b. HOT&COLD WATER SUPPLY PIPING (EXCEPT RUN OUTS 12 FT. OR SHORTER TO INDIVIDUAL FIXTURES)SHALL � � a � � � 15. DUCTWORK INSULATION: b. PROVIDE MOTORS AND EQUIPMENT FOR ONLY THOSE CURRENT CHARACTERISTICS INDICATED ON THE BE INSULATED AS FOLLOWS: � , 4.SITE INSPECTION: a.ALL DUCTWORK SHALL BE INSULATED CONSISTENT WITH THE REQUIREMENTS PER SECTION 604 OF THE 2009 DRAWINGS. PIPE SIZE (IN.) INSULATION THICKNESS (IN.) .� � � � � � a. CONTRACTOR SHALL VISIT THE SITE OF WORK PRIOR TO SUBMISSION OF HIS BID AND THOROUGHLY IMC. c. IT IS THE INTENT OF THIS DIVISION TO REQUIRE A COMPLETE SYSTEM PER THE CONTRACT DOCUMENTS. 1/2", 3/4"& 1" 1" � '� w �'ti � FAMILIARIZE HIMSELF WITH THE WORKING CONDITIONS &EXACT NATURE OF THE WORK. b. INSULATION SHALL BE UL LISTED IN COMPLIANCE WITH A FLAME-SPREAD INDEX NOT MORE THAN 25 AND d.COORDINATE ALL EQUIPMENT REQUIRING ELECTRICAL POWER, REGARDLESS OF VOLTAGE, WITH OTHER 1 1/4"THROUGH 6" 1 1/2" w U J = O � b. SUBMISSION OF A BID ACKNOWLEDGES FULL RESPONSIBILITY FOR FURNISHING A COMPLETE AND FUNCTIONAL SMOKE DEVELOPED INDEX NOT MORE THAN 50, PER THE 2009 IMC. INSTALLATION SHALL BE IN ACCORDANCE TRADES, SO THAT ALL SYSTEMS ARE COMPLETE AND OPERATIONAL. c. NO HOT OR COLD WATER PIPING SHALL BE ROUTED IN EXTERIOR WALLS UNLESS PROPERLY INSULATED. � � � ti � SYSTEM. WITH IMC REQUIREMENTS. e.ALL THREE PHASE MOTORS SHALL BE PROVIDED WITH PHASE LOSS PROTECTION. d. CONDENSATE PIPING SHALL BE INSULATED WITH 3/8" FOAM PLASTIC. � w +� � � c. NO CHANGES IN CONTRACT WILL BE MADE TO ACCOMMODATE OR ALLOW EXTRA FUNDS FOR ANY OMISSION c. RECTANGULAR SUPPLY, RETURN &TRANSFER DUCTWORK SHALL BE INTERNALLY LINED WITH A VAPOR f. ALL SINGLE AND THREE PHASE MOTORS, STARTERS AND DISCONNECTS PROVIDED BY MECHANICAL � � � � � WHICH RESULTS FROM A FAILURE TO THOROUGHLY MAKE THE EXAMINATION. RESISTANT DUCT LINER OF THICKNESSES SPECIFIED BELOW. CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR. 14. PIPING: �' U N O � d.CONCEALED ROUND, CONCEALED OVAL &OUTDOOR AIR DUCTS SHALL BE EXTERNALLY WRAPPED WITH a. WASTE AND VENT DRAIN PIPING: V '� .�? 00 O 5.CODES AND PERMITS: FIBERGLASS INSULATION WITH AN EXTERNAL VAPOR BARRIER. REQUIRED R-VALUES ARE SPECIFIED BELOW. 29. TEMPORARY HEATING DURING CONSTRUCTION: i. SHALL BE STANDARD WEIGHT CAST IRON HUB LESS TYPE. � R3 � � '� a. ALL MECHANICAL EQUIPMENT, INSTALLATION, ETC., SHALL CONFORM TO THE 2012 INTERNATIONAL MECHANICAL e. ALL SUPPLY, RETURN &TRANSFER DUCTWORK LOCATED WITHIN THE BUILDING ENVELOPE SHALL BE a.MECHANICAL EQUIPMENT SHALL NOT BE UTILIZED FOR TEMPORARY HEATING. ii. UNDERGROUND PIPING CAN ALSO BE SCHEDULE 40 PVC. �- V O � N CODE (IMC), 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)AND ORDINANCES AS INTERPRETED BY INSULATED TO A MINIMUM OF R-4 (1" LINER) UNLESS SPECIFIED OTHERWISE ON THE PLANS. b. GAS FIRED TEMPORARY HEAT SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. iii.VENT PIPING IN RETURN AIR CEILING PLENUMS SHALL BE ABS OR COPPER PIPING. � � � � N THE TOWN OF VAIL BUILDING DEPARTMENT. f. ALL SUPPLY& RETURN DUCTWORK SHALL BE INSULATED TO A MINIMUM OF R-5 (1-1/2" LINER)WHEN LOCATED IN b. WATER PIPING: V � Q � � b. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS. UNCONDITIONED SPACES AND SHALL BE INSULATED TO A MINIMUM OF R-8 (2" LINER)AND WEATHERPROOFED i. SHALL BE TYPE"L" COPPER HARD DRAWN WITH WROUGHT COPPER FITTINGS. � � c. COPIES OF ALL PERMITS AND INSPECTION REPORTS SHALL BE SUBMITTED TO THE ARCHITECT. WHEN LOCATED OUTSIDE THE BUILDING. P L U M B I N G S P EC I F I CAT I O N S. ii. JOINTS SHALL BE SOLDERED WITH 95-5 OR SILVER SOLDER. � � g.ALL OUTDOOR AIR DUCTS SHALL BE INSULATED TO A MINIMUM OF R-6 WITH A VAPOR BARRIER. iii.WATER PIPING 1 1/4" &SMALLER CAN ALSO BE WIRSBO AQUAPEX APR, REHAU RAUPEX OR EQUIVILANT-PROVIDE m 6.AS-BUILTS: 1. GENERAL: DEDUCT ALTERNATE PRICING. � a. CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS-BUILT DOCUMENTS WITH ALL CHANGES NOTED 16. PIPING INSULATION: a.FURNISH ALL LABOR, SUPERVISION, MATERIALS, EQUIPMENT AND FACILITIES NECESSARY TO FURNISH, c. CONDENSATE PIPING SHALL BE TYPE "M" COPPER WITH SOLDER JOINTS. � THEREON AT THE COMPLETION OF THE PROJECT AND PRIOR TO FINAL ACCEPTANCE AND PAYMENT. a.ALL HYDRONIC PIPING SHALL BE INSULATED CONSISTENT WITH THE REQUIREMENTS PER SECTION 1204 OF THE FABRICATE, DELIVER, STORE AND INSTALL ALL WORK NOTED ON THE DRAWINGS AND/OR SPECIFIED HEREIN. 2009 IMC. b. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL WORK NECESSARY TO MAKE A COMPLETE SYSTEM 15. EACH PLUMBING VENT SHALL TERMINATE NOT LESS THAN TEN FEET FROM ANY MECHANICAL INTAKE AND AT 7. GUARANTEE: b. INSULATION SHALL BE UL LISTED IN COMPLIANCE WITH A FLAME-SPREAD INDEX NOT MORE THAN 25 AND WHETHER OR NOT SUCH DETAILS ARE MENTIONED IN THESE SPECIFICATIONS OR SHOWN ON THE PLANS, BUT LEAST THREE FEET FROM ANY OPENING INTO THE BUILDING. ���ax krs�i7 cz,,. a. CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL LABOR AND MATERIALS ON ALL WORK AGAINST SMOKE DEVELOPED INDEX NOT MORE THAN 450, PER THE 2009 IMC. INSTALLATION SHALL BE IN ACCORDANCE WHICH ARE OBVIOUSLY NECESSARY TO MAKE A COMPLETE SYSTEM, EXCEPTWG ONLY THOSE PORTIONS THAT �5`�'�'",�.' r�4 +.,r,�*�,r,� DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER COMPLETION. WITH IMC REQUIREMENTS. ARE SPECIFICALLY MENTIONED HEREIN OR PLAWLY MARKED ON THE ACCOMPANYING DRAWINGS AS BEING 16. CLEAN-OUTS SHALL BE INSTALLED AS PER 2009 IPC SECTION 708. :�`S��j`G'` ,� �J?� -, c. ALL HYDRONIC PIPING INSULATION SHALL HAVE A THERMAL CONDUCTIVITY LESS THAN OR EQUAL TO 0.27 INSTALLED UNDER ANOTHER SECTION OF THE SPECIFICATIONS. ,�` t ,�� 8.SUBMITTALS: BTU-IN/HR-FT2-OF. 17. PROTECT ROOF RECEPTOR ON ROOF FROM RAIN WATER BY ELEVATING THE RIM 2 '/2" INCHES ABOVE ROOF - �- ` a.CATALOG INFORMATION AND CUTS OF ALL EQUIPMENT AND DEVICES SHALL BE SUBMITTED TO THE ARCHITECT d. ALL HEATING WATER PIPING 1-1/2" OR SMALLER SHALL BE INSULATED WITH 1-1/2"THICKNESS. HEATING WATER 2.WORKMANSHIP: SURFACE. � 29840 � ' �: FOR REVIEW (SIX COPIES OF EACH). PIPING LARGER THAN 1-1/2"SHALL BE INSULATED WITH 2"THICKNESS. a.THE WORK SHALL BE ACCOMPLISHED IN A THOROUGH AND WORKMAN-LIKE MANNER SATISFACTORY TO AND � � �r � q �; e. ALL CHILLED WATER PIPING SHALL BE INSULATED WITH 1-1/2"THICKNESS WITH AN APPROVED VAPOR BARRIER. MEETING THE APPROVAL OF THE OWNER AND ARCHITECT. 18. PROVIDE WATERTIGHT FLASHING WHEREVER PIPES PASS THRU EXTERIOR WALLS, ROOF AND FLOORS. ����j A�"�Z3�Z--���``,` 9.COORDINATION: f. ALL PIPING ROUTED BELOW THE SLAB UNDERGROUND SHALL BE TYPE"k" COPPER AND SHALL BE INSULATED � a.THE DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW SCOPE. 3. MATERIALS: �`�r,5`�;�ONAL�<1�1ti'`�i' WITH ARMIFLEX TYPE INSULATION. 19. PENETRATION IN WALLS REQUIRING PROTECTED OPENINGS SHALL BE FIRE-STOPPED. FIRE-STOPPING SHALL BE •�,,z;��7,�1�n,,�` b. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES TO PROVIDE BEST ARRANGEMENT OF a.ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND THE BEST OF THEIR RESPECTIVE KIND, FREE FROM ALL AN APPROVED MATERIAL SECURELY INSTALLED AND CAPABLE OF MAINTAINING ITS INTEGRITY WHEN SUBJECTED ALL DUCTS, PIPES, CONDUIT, ETC. 17. TEMPERATURE CONTROL DEVICES: DEFECTS AND OF THE MAKE AND QUALITY SPECIFIED. TO TEST TEMPERATURE FOR SPECIFIC WALL OR PARTITION. a.THE HVAC SYSTEM SHALL BE PROVIDED WITH 7-DAY PROGRAMMABLE AUTOMATIC SPACE TEMPERATURE 10. CUTTING AND PATCHING: CONTROL DEVICES (THERMOSTATS)AS SHOWN ON THE PLANS. THE THERMOSTATS SHALL BE CAPABLE OF 4.SITE INSPECTION: 20. PROVIDE FELT WITH METAL BACKING VIBRATION ISOLATION SLEEVES OR PADS AT ALL PIPE HANGERS OR a. ALL CUTTING AND PATCHING REQUIRED OF THE STRUCTURE (NEW OR EXISTING)SHALL BE PROVIDED UNDER SCHEDULING OCCUPANCIES AND PROVIDING SETBACK CAPABILITIES TO MAINTAIN ZONE SETPOINTS DOWN TO a.CONTRACTOR SHALL VISIT THE SITE OF WORK PRIOR TO SUBMISSION OF HIS BID AND THOROUGHLY SUPPORTS AND ALL POINTS WHERE PIPING COMES IN CONTACT WITH ANY PORTION OF THE STRUCTURE. APPLIES OTHER SECTIONS OF THE WORK. 55°F OR UP TO 85°F. FAMILIARIZE HIMSELF WITH THE WORKING CONDITIONS& EXACT NATURE OF THE WORK. TO ALL WATER AND WASTE PIPING. b. PROVIDE NECESSARY REQUIREMENTS TO THE PROJECT SUPERINTENDENT. b. CONTROLS SHALL BE CAPABLE OF OPERATING THE SYSTEM HEATING AND COOLING IN SEQUENCE AND SHALL b. SUBMISSION OF A BID ACKNOWLEDGES FULL RESPONSIBILITY FOR FURNISHING A COMPLETE AND FUNCTIONAL � � c. X-RAY SLABS PRIOR TO CORING. BE ADJUSTED TO PROVIDE A DEADBAND OF AT LEAST 5°F BETWEEN HEATING AND COOLING. SYSTEM. 21. LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE. CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND c. THERMOSTATS SHALL HAVE NUMERIC SET POINTS IN °F, ADJUSTABLE SETPOINT STOPS AND SHALL BE c. NO CHANGES IN CONTRACT WILL BE MADE TO ACCOMMODATE OR ALLOW EXTRA FUNDS FOR ANY OMISSION DEPTHS OF UTILITIES PRIOR TO STARTING WORK OF THIS SECTION. MAKE REQUIRED ADJUSTMENTS TO � 11. CLEANUP: MOUNTED AT 48"ABOVE FINISHED FLOOR ADJACENT TO THE ROOM'S LIGHT SWITCH. WHICH RESULTS FROM A FAILURE TO THOROUGHLY MAKE THE EXAMINATION. CONNECT TO EXISTING UTILITIES. IF INDICATED POINTS OF CONNECTION CANNOT BE MADE TO UTILITIES AS FOUND, > a.UPON COMPLETION OF THE WORK UNDER THIS SECTION, THE CONTRACTOR SHALL REMOVE ALL SURPLUS THE CONTRACTOR SHALL, BEFORE CONTINUING, NOTIFY THE ARCHITECT PRIOR TO INSTALLING ANY WORK WHICH � MATERIALS, EQUIPMENT AND DEBRIS INCIDENTAL TO THIS WORK AND LEAVE THE PREMISES CLEAN AND 18. BEFORE STARTING ANY WORK, THE CONTRACTOR FOR THIS SECTION OF THE WORK SHALL EXAMINE A 5. CODES AND PERMITS: MAY BE AFFECTED. O ORDERLY. COMPLETE SET OF DRAWINGS FOR ALL TRADES, INCLUDING ARCHITECTURAL, STRUCTURAL, HVAC, ELECTRICAL, a.ALL PLUMBING EQUIPMENT, INSTALLATION, ETC., SHALL CONFORM TO THE 2012 INTERNATIONAL PLUMBING � � FIRE PROTECTION AND PLUMBING. DIMENSIONS, SPACE REQUIREMENTS AND POINTS OF CONNECTION TO ALL CODE (IPC), 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)AND ORDINANCES AS INTERPRETED BY 22. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AVAILABLE SPACES FOR INSTALLING THE WORK. 12. MECHANICAL IDENTIFICATION EQUIPMENT SHALL BE VERIFIED, AND ANY MINOR ADJUSTMENTS NECESSARY TO AVOID CONFLICT WITH THE THE TOWN OF VAIL BUILDING DEPARTMENT. � a.EQUIPMENT NAMEPLATES: METAL, WITH DATA ENGRAVED OR STAMPED, FOR PERMANENT ATTACHMENT ON gUILDING STRUCTURE AND THE WORK OF THE OTHER TRADES SHALL BE MADE. CONTRACTOR SHALL NOTIFY b. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS. 23. VALVES SHALL BE NIBCO, JENKINS, WALWORTH, STOCKHAM OR EQUAL. SERVICE PRESSURE SHALL BE � EQUIPMENT. ARCHITECT IMMEDIATELY IF ANY MAJOR CONFLICTS OCCUR. c. COPIES OF ALL PERMITS AND INSPECTION REPORTS SHALL BE SUBMITTED TO THE ARCHITECT. SUITABLE FOR SERVICE INTENDED. � b. PIPE MARKERS: PREPRINTED, COLOR CODED, WITH LETTERING INDICATING SERVICE,AND SHOWING DIRECTION � U OF FLOW. 19. COORDINATE LOCATIONS OF ALL ROOF AND EXTERIOR WALL OPENINGS WITH ALL RELEVANT TRADES, AND 6. AS-BUILTS: 24. PROVIDE HANGERS AND SUPPORTS MEETING THE REQUIREMENTS SPECIFIED IN THE 2009 IPC SECTION 308. O c. VALVE TAGS: STAMPED OR ENGRAVED WITH 1/4" LETTERS FOR PIPING SYSTEM ABBREVIATION AND 1/2" PROVIDE WATERTIGHT FLASHINGS WHEREVER PENETRATIONS OCCUR. EXACT LOCATIONS AND SIZES MAY BE a.CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS-BUILT DOCUMENTS WITH ALL CHANGES NOTED PLUMBERS TAPE AND WIRE ARE NOT ACCEPTABLE. Z W 0 NUMBERS, WITH NUMBERING SCHEME. PROVIDE 5/32" HOLE FOR FASTENER. DEPENDENT UPON EQUIPMENT SELECTIONS� COORDINATE SIZES AND LOCATIONS OF ALL OPENINGS WITH THEREON AT THE COMPLETION OF THE PROJECT AND PRIOR TO FINAL ACCEPTANCE AND PAYMENT. Q d. VALVE TAG SCHEDULE: PREPARE A VALVE TAG SCHEDULE TO BE SUBMITTED TO THE MAINTENANCE ENGINEER APPROPRIATE EQUIPMENT REQUIREMENTS. 25. CONTRACTOR SHALL AFFIX A MAINTENANCE LABEL TO ALL EQUIPMENT REQUIRING ROUTINE MAINTENANCE AND � � � � FOR RECORD. 7. GUARANTEE: SHALL PROVIDE THREE COPIES OF MAINTENANCE AND OPERATING MANUALS TO THE OWNER/OPERATOR. � 20. PERMANENT ACCESS TO EQUIPMENT SHALL BE PROVIDED, AND A MINIMUM OF 30"CLEAR WORKING SPACE IN a.CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL LABOR AND MATERIALS ON ALL WORK AGAINST O 13. DUCTWORK: FRONT OF ACCESS PANELS TO THE COMPRESSOR, BLOWER ASSEMBLY AND AIR FILTER SECTION OF THE DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER COMPLETION. 26. CONTRACTOR SHALL ARRANGE FOR AND PAY FOR ALL UTILITY METERS AND UTILITY CONNECTIONS. O a.DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE 2009 IMC AND SMACNA EQUIPMENT SHALL BE PROVIDED BY GENERAL CONTRACTOR. O STANDARDS. 8. SUBMITTALS: 27, ALL PLUMBING LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO THE GREATEST EXTENT � J b. DUCTWORK SHALL BE GALVANIZED STEEL GAUGES TO MEET SMACNA STANDARDS. DUCTWORK SIZES 21. ALL EQUIPMENT SHALL BE SECURELY FASTENED TO THE BUILDING STRUCTURE WITH CODE APPROVED a.CATALOG INFORMATION AND CUTS OF ALL EQUIPMENT AND DEVICES SHALL BE SUBMITTED TO THE ARCHITECT POSSIBLE. ALL LINES NOT CONCEALED SHALL BE SECURED 6"OFF FLOOR AND 3/4" FROM WALL AND CEILINGS � � � O INDICATED ARE FREE CLEAR DIMENSIONS. VIBRATION ISOLATORS. FOR REVIEW(SIX COPIES OF EACH). USING OFFSET BRACKETS. � c. ALL DUCT JOINTS SHALL BE SEALED AIR TIGHT WITH RCD CORP.#6 MASTIC ADHESIVE WITH VERSA GRIP OR MESH. 22. EACH PIECE OF EQUIPMENT AND ALL SYSTEMS SHALL BE ADJUSTED AND RE-ADJUSTED TO INSURE PROPER 9� COORDINATION: 28. AN APPROVED BACKFLOW PREVENTER SHALL BE PROPERLY INSTALLED UPSTREAM OF ANY POTENTIAL HAZARD � .. d.FLEXIBLE DUCT USED FOR CONDITIONED AIR SHALL BE UL APPROVED, VINYL COATED, WIRE REINFORCED FUNCTION OF ALL CONTROLS, MAINTENANCE OF TEMPERATURE,ADEQUACY OF FLOWS AND CAPACITIES, a.THE DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW SCOPE. BETWEEN THE POTABLE WATER SUPPLY AND A SOURCE OF CONTAMINATION. J FIBERGLASS, WITH MAXIMUM THERMAL CONDUCTIVITY OF 0.30 BTU-IN/HR-FT2-OF AND A MAXIMUM LENGTH OF ELIMINATION OF NOISE AND VIBRATION, AND SHALL BE LEFT IN PROPER OPERATING CONDITION. b. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES TO PROVIDE BEST ARRANGEMENT OF � � � FIVE FEET. ALL DUCTS, PIPES, CONDUIT, ETC. 29. ALL SINGLE AND THREE PHASE MOTORS, STARTERS AND DISCONNECTS SHALL BE PROVIDED BY THE PLUMBING � � e. CLOTHES DRYER VENT EXHAUST DUCTWORK SHALL BE ALUMINUM. DUCTWORK SHALL NOT BE CONNECTED OR 23. TEST& BALANCING: CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR. � C� INSTALLED WITH SHEET METAL SCREWS OR OTHER FASTENERS THAT WILL OBSTRUCT THE EXHAUST FLOW. a.THE ENTIRE HEATING AND VENTILATING SYSTEM SHALL BE BALANCED BY AN INDEPENDENT CERTIFIED TEST 10. CUTTING AND PATCHING: O > TERMINATE WITH A WALL CAP WITH A BACK DRAFT DAMPER. SCREENS ARE PROHIBITED. REFER TO SECTION AND BALANCE COMPANY. a.ALL CUTTING AND PATCHING REQUIRED OF THE STRUCTURE (NEW OR EXISTING)SHALL BE PROVIDED UNDER � 504 OF THE 2009 IMC FOR MAXIMUM DRYER EXHAUST DUCT LENGTHS. b. 5 COPIES OF THEIR BALANCE REPORTS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW AND APPROVAL. OTHER SECTIONS OF THE WORK. U f. DISHWASHER EXHAUST DUCTWORK SHALL BE ALUMINUM CONSTRUCTION TO MEET SMACNA STANDARDS. c. ALL REQUIRED RE-SHEEVING AND ADJUSTING OF EQUIPMENT SHALL BE MADE BY THE TEST& BALANCE b. PROVIDE NECESSARY REQUIREMENTS TO THE PROJECT SUPERINTENDENT. � SLOPE DUCTWORK BACK TO THE DISHWASHING HOOD. CONTRACTOR. c. X-RAY SLABS PRIOR TO CORING. w g.DUCTWORK SHALL BE SIZED AT A MAXIMUM VELOCITY OF 1,000 FPM/.08" PRESSURE DROP PER 100 FEET. d.ALL FINAL MEASURED CAPACITIES SHALL BE WITHIN 10% OF THOSE INDICATED ON THE PLANS. O O � O PROVIDE FREEZE-STAT DOWNSTREAM � O OF HEATING COIL OR ON CONDENSING ALL THREAD ROD COIL PER MANUFACTURERS � N VIBRATION ISOLATING HANGER(TYP.) INSTRUCTIONS. FLEXIBLE CANVAS CONNECTOR BRASS CLEANOUT PLUG W/COUNTER SUNK HEAD SUC CLEANOUT AND ACCESS 16"f1� CONC. PAD TROWEL AEC PROJECT #: 13063 FLOOR COVER. TOP OF COVER SMOOTH & EDGE � � LINE TO BE FLUSH W/TOP OF CHROME WALLCOVER � FLOOR FINISHED GRADE r � 1" LINED SUPPLY DUCTWORK DATE: ISSUE: AND SCREW - ° 6� I I 08-06-13 PERMIT - - - - FANCOIL - - - - - - I I 08-16-13 PERMIT REVISION � PLUGGED TEE WITH `-1/8 C.I. BEND I I I 1/8 C.I. BEND / CLEAN OUT I I BALANCE OF PIPWG LIQ ° SAME AS CLEANOUT C.I. WASTE LINE. - - - - - - I I - - FLOOR LINE TO GRADE. LGTH TO SUIT. I I a I I 1" LINED RETURN J �I D� DRAIN � FLOOR CLEANOUT FCO ��� Drawn B : Checked B : ( ) DUCTWORK STRAINER(TYP.) o n v � o 0 o EXPANSION VALVE 0 0 o v v v CLEANOUT NOT TO BE LOCATED 0 0 °o° o � v o � o o IN CARPETED AREA. PROVIDE MERV-11 FILTER. SHUT-OFF VALVE (TYP.) KBW TOC / WASTE LINE %$' C.I. BEND UNI-STRUT SUPPORT RAIL INTERNAL DRAIN PAN, CONDENSATE DRAIN MECHANICAL CLEANOUT TO GRADE (COTG) 1/8 BEND IF CLEANOUT & P-TRAP. OUTLET 1" LOWER THAN INLET & PLUMB ING OCCURS AT END OF LINE. THE MECHANICAL CONTRACTOR SHALL FIELD ESTABLISH THE SPECIFIC FAN COIL UNIT'S COIL PIPING ARRANGEMENT& FAN ACCESS PRIOR TO SUBMITTING TO THE MANUFACTURER FOR PURCHASING. DETAILS lX. WALL CLEANOUT DIAGRAM NOSCALE CLEANOUT SCHEMATICS D/X FAN COIL UNIT DETAIL SPEC�S NO SCALE NO SCALE NO SCALE • 1 of 2 �COPIRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS,INC, 0 N MINI SPLIT AIR CONDITIONING UNIT SCHEDULE OREQUIVALENT GREASE INTERCEPTOR SCHEDULE OREQUIVALENT � SYSTEM INDOOR UNIT OUTDOOR UNIT ELECTRICAL DATA FLOW DIMESSIONS (IN) OPER. (/� p UNIT MANUFACTURER& UNIT MANUFACTURER& GREASE CAPACITY INLET SIZE OUTLET �+ SERVICE COOL WEIGHT S.P WEIGHT REMARKS SERVICE LOCATION RATE WEIGHT REMARKS � TAG MODEL NO. SEER W(IN) D(IN) H(IN) CFM MCA W(IN) D(IN) H(IN) MCA V/PH/Hz W TAG MODEL NO. (LBS) (GAL.) � H w (IN) SIZE (IN) � tn N (T5 � (MBH) (LBS) ("WC) (LBS) (GPM) (LBS) � � — i- N �--� U (� � Ln MITSUBISHI- 618- CU-1: PUY-A30NHA4 � O pp FC-1 PEAD-A30AA4 COOLING 30.0 15.5 43.3 28.88 9.88 73 883 0.40 2.7 37.38 14.19 37.13 163 25.0 208/1 /60 3850 NEOPRENE VIBRATION ISOLATION. GI-1 GT2701-20 FLOOR SINKS PARKING GARAGE 20 40 15 32.375 10 20.75 3 3 102 � � p U ' � � � �� � � � � � ti MECHANICAL DAMPER SCHEDULE PLUMBING FIXTURE CONNECTION SCHEDULE �j ��� �� OR EQUIVALENT � Q I` INLET CFM MAX MAX OPER. � � � � UNIT MANUFACTURER& VELOCITY UNIT COLD HOT � N � jC O SERVICE LOCATION SIZE APD SOUND WT. REMARKS MANUFACTURER& MODEL NO DESCRIPTION WASTE VENT REMARKS ��' N ti3 U TAG MODEL NO. ��N� (FPM) MIN. �� (IN.WC) LVL(NC) (LBS) TAG WATER WATER � � � � � _ .� � � � _ HONEYWELL LV LAVATORY 1-1/2" 1-1/2" 1/2" 1/2" - � � U O.� MD-1 Zp OUTDOOR AIR ABOVE CEILING 12X5 740 0 250 0.10 25 N/A MOTORIZED DAMPER INTERLOCKED WITH EF-1 � J � � WC WATER CLOSET 3" 2" 1/2" — — � Q N � (� PLUMBING FIXTURE SPECIFICATIONS&HARDWARE — � � �S QO Q� HS HANDSINK 1-1/2" 1-1/2" 1/2" 1/2" — •� AI R D E V I C E S C H E D U L E SELECTION TO BE BY THE INTERIOR DESIGNER. FIXTURE N � CO Op � OREQUIVALENT ALLOWANCENOTTODCCEFDTHEESTABLISHED � •V W >+� � MS BUDGET. �PSINK 2" 1-1/2" 3/4" 3/4" 1 � 1 }, w � � LJJ V UNIT MANUFACTURER& MOUNTING FRAME � TS TRIPLESINK 2" — 3/4" 3/4" — � J = O � TAG MODEL NO. USE LOCATION STYLE �E FINISH SOUND REMARKS � ti LVL(NC) FS FLOORSINK 3" 1-1/2" - - - � w'� � � 1/2"30° SINGLE COORD.W/ +� � � � A TITUS-25RL SEE PLAN CEILING - 25 STEEL CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS,SIZES,AND SPECIFIED CFMS. CO ZURN ZN1400 CLEAN OUT VARIES - - - - U N O C DEFLECTION GRILLE ARCH V �C •V � � WCO ZURN Z1441 WALL CLEAN OUT VARIES - - - - � � � � "� EXTERIOR 1/2"35° SINGLE COORD.W/ }' � O � � B TITUS-355FL LOUVER EXTERIOR WALL DEFLECTION GRILLE ARCH 25 ALUMINUM CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS,SIZES,AND SPECIFIED CFMS. COTG ZURN Z1400 CLEAN OUT TO GRADE VARIES - - - LOCATE WITHIN 5'OF THE BUILDING � � C d� � L � a � ~ � AIR CURTAIN SCHEDULE OREQUIVALENT OUTDOOR AIR VENTILATION MECHANICAL/NATURAL a � m ELECTRICAL DATA DIMENSIONS NOISE OPER. NATURAL NATURAL UNIT MANUFACTURER& TOTAL ROOM SIZE CFM/ TOTAL 0 LOCATION TYPE � H W LEVEL WT. REMARKS ROOM �SQ.FT.) # PEOPLE PERSON CFM/ SF CFM VENTILATION VENTILATION REMARK � TAG MODEL NO. CFM POWER V/PH/Hz FLA (IN) (IN) (IN) (dBA) (LBS) REQ. (SQ.FT.) AVAILABLE (SQ.FT.) ABOVE FRONT EXISTING EQUIPMENT ON SITE. FURR OUTAPPROX.3"FROM WALL TO AVOID CONFLICT WITH ���x AG1 E-AIR-EAC1200L EXPOSED - 400 W 120/1 /60 4 46 9 10 - - RETAIL AREA 640 10 7.5 0.12 152 - - 250 CFM MECHANCAL VENTILATION PROVIDED k� �,�. DOOR CONDUIT.ANGLE AIR BACK AT DOOR. INSTALL CLOSED DOOR LIMIT SWITCH. �5�`�' +�.; r�4 �.�r� *.,t,� �y� .. �T �-, Total CFM 152 �y*1 J``� � �` :�=�, SHEET DETAIL NOTES: GENERAL NOTES. MECHANICALVENTILATIONBASEDONIMC2012TABLE403.3 � s ,=- � _. � 29s40 � • � 1O EXISTING EXHAUST FAN TO REMAIN. 1. ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE. � � 'rsrJ � � :�`� �� f j�A�Z3��t O2 ROUTE 12x5 DUCT UP THROUGH SLOPED CEILING TO ACCESS 2. ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER ���.5��,�D�pL�<1�44,,i' EXTERIOR WALL AND GRILLE. UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND '�'!rr,�;Q�7�1,x1v7'` DUCTWORK SHALL BE WRAPPED WITH 1.5"THICK INSULATION UNLESS O3 CONNECT GRILLE IN INTERIOR CEILING AND EXTERIOR WALL WITH 12x5 OTHERWISE NOTED. DUCT ABOVE CEILING. PROVIDE ACCESS TO MD-1 AS SHOWN. 3. ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE O4 LOCATE CONDENSING UNIT IN GARAGE BELOW. EXACT LOCATION TO CONICAL TEES. BE DETERMINED ON SITE WITH OWNER,ARCHITECT AND MECHANICAL � � CONTRACTOR. 4. ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES. OFC-1 TO BE MOUNTED ABOVE CEILING IN BATHROOM. PROVIDE 5. ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL � ACCESS IN CEILING. ROUTE 5/"&%$" REFRIGERANT LINES TO INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY. > CONDENSING UNIT W GARAGE BELOW ACCORDING TO z � MANUFACTURERS RECOMMENDATIONS. LINES TO PASS THROUGH 6. COORDINATE ALL ACCESS PANE� LOCATIONS WITH THE ARCHITECT. O EXISTING HOLE BENEATH MOP SINK. DETERMINE EXACT ROUTING IN � FIELD. 7. ALL WASTE PIPING SHOWN DASHED TO BE LOCATED BENEATH FLOOR. � 8. INSTALL CLEANOUTS AS RE UIRED BY SECTION 708 OF 2012 IPC. � O EXISTING FIXTURE TO REMAIN. ENSURE CONNECTIONS &PIPING Q 4 CU Q INTEGRITY AND REPLACE IF NECESSARY. � � � U O7 CONNECT Yz" CW,%2" HW, 1 %z"W& 1 %"V TO HS &SS. _ _ O N � TS g �c.�n � � 0 3 �� 3 � 1 �� - � O8 CONNECT /4 CW, /4' HW, 2"W& 1 / V TO MS. � _ 883-R � �� O � 12x22 A �J o WCO6 � � � O9 CONNECT%4" CW, %4" HW&2"W TO TS. CONNECT W TO FS VIA � INDIRECT CONNECTION. � E EF 5 FC APPROXIMATE LOCATION OF 5" HOLE TO GARAGE FOR REFRIGERANT LINES. CONFIRM 12 �� � �� F S 1 0 O�L � � SIZE REQUIREMENT WITH MECHANICAL CONTRACTOR PRIOR TO DRILLING OR ENLARGING. �VO 12 � � �2��W O O O O 10 CONNECT 2"W& 1 �"V TO FS. � 3„W w J �`�—�° � MS O8 I Fig O7 O 11 GI-1 TO BE LOCATED IN GARAGE. EXACT LOCATION TO BE � _ _ (EX) 12x12 _ C– � � � DETERMINED ON SITE. CONNECT 3"W AT ENTRY& EXIT. _ v�v - -v� � U _ �r � � � -� , 12 CONTINUE W&V TO EXISTING WASTE&VENT LINES. ENSURE Yo;, , � 14 �$ 1 1/2"W � � ^ EXISTING PIPE CAN HANDLE ADDITIONAL LOAD. n�, I I N N II NI � � � � _ � � � J II , � J 13 ROUTE 1 %2'W& 1 %"V TO EXISTING LV. CONNECT W PRIOR TO � FS 10 � � � PENETRATING FLOOR, AND V PRIOR TO PENETRATING CEILING. 2��W � \ APPROXIMATE LOCATIONS OF I I I O / 14 ROUTE 2"W FROM YOGURT STAND TO FS AND CONNECT VIA INDIRECT EXISTING DUCTS AND DIFFUSERS 13 � 1 %2"W&V � CONNECTION. I I V � U 15 EQUIPMENT ALREADY ON SITE. INSTALL APPROXIMATELY 3"OFF WALL P.o.s. 9' I I � � P.O.S. `�'LASE � W O O TO AVOID CONDUIT. ANGLE AIR BACK TOWARDS DOOR. � I � � a O 16 EXISTING DIFFUSERS WILL PRODUCE NOISE LEVEL OF 50 N.C. I I � O O ; � O COORDINATE WITH OWNER IF NOISE WILL BE AN ISSUE AND REPLACE _ � I (E)8"f?� (TYP. OF 3) � � � w � O WITH LARGER DIFFUSER. CONFIRM IN FIELD I � � � HSO ;W� 17 EXISTING 250 CFM EXHAUST FAN IN HOOD TO SERVE VENTILATION �— �� -�� U N PURPOSES. 16 (EX) 295-S � 295-S 295-S _ -��� 12x4 �6 (EX) 12x4 12x4 �EX) 16 �s SS 7 � O � 18 CONNECT TO EXISTING SEWER LINE IN THE GARAGE CEILING BELOW. Q LC– — Q � O � �D� � C— � AEC PROJECT #: 13063 17 ' ' � �� � DATE: ISSUE: SEQUENCE OF OPERATIONS: W ' -�� W 08-06-13 PERMIT HEATING: ¢ � i i a 08-16-13 PERMIT REVISION � HEATING SHALL BE CONTROLLED BY A WALL MOUNTED THERMOSTAT. UPON �, � ' X ��� ..AY � � DISPLAY � � A CALL FOR HEAT THE EXISTING BASEBOARD HEATERS SHALL ACTIVATE N 250-OA � � z AND REMAIN ON UNTIL THE CALL IS SATISFIED. AC / 12x6 '4 i i `� 1 15 I I � COOLING: � � i i COOLING SHALL BE CONTROLLED BY THE MANUFACTURER'S PROVIDED ' 12x12 ACCESS PANEL REMOTE CONTROL UNIT. UPON A CALL FOR COOLING THE FAN COIL AND 12x5 � i IEXISTING BASEBOARD EXISTING BASEBOARD CONDENSING UNIT SHALL OPERATE UNTIL THE CALL IS SATISFIED. Drawn By: Checked By: INTERLOCK WITH (E) BASEBOARDS AND BLOCK THEM WHEN IN COOLING MD MODE. B 250-EX B 250-OA 1 � KBw T�C 10x6 10x6 I � �, VENTILATION: I VENTILATION IS PROVIDED BY A 250 CFM (E) EXHAUST HOOD INTERLOCKED L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ J MECHANICAL WITH A MECHANICAL DAMPER ON AN OUTDOOR AIR DUCT. DURING OCCUPIED HOURS THE HOOD SHALL BE SWITCHED ON TO EXHAUST AIR AND & PLUMB ING THE INTERLOCKED DAMPER SHALL OPEN TO ALLOW OUTSIDE AIR TO ENTER THE SPACE. NORTH NORTH PLAN & MECHANICAL PLAN PLUMBING PLAN SCHEDULES SCALE 1/4" = 1'-0" SCALE: 1/4"= 1'0" SCALE: 1/4"= 1'0" • 2 Of 2 �COPIRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS,INC,