B13-0321 CR1 PLANS.pdf
I B13 - 0321 ABBIREVIATIONS AB ANCHOR BOLT ////i=� AB ABOVE AD AREA DRAIN GPSL Architects, p.c. ADJ ADJACENT Nil AFF ABOVE FINISH FLOOR 953 S. Frontage Rd. West Vail, Colorado 81657 ALUM ALUMINUM tel: 970.476.1147 ALT ALTERNATE gpslarchitects.com AP ACCESS PANEL Z. ANGLE B.O. BOTTOM OF CLG GE I L I NG of Vail G I CAST IRON CJ CONTROL JOINT CENTER LINE CLR COLOR GMU CONCRETE MASONRY UNIT co GLEANOUT O COL COLUMN GONG CONCRETE CONT CONTINUOUS u DO DOUBLE WALL OVENS DW DISHWASHER Ea EQUAL FD FLOOR DRAIN LU 0 FDN FOUNDATION - FIN FINISH FLR FLOOR L — F.O.W. FACE OF WALL(STUD,ETC) FTC, FOOTING 4 GYP GYPSUM WALL BOARD GL GLASS/GLAZ I NG ~ LL LU HM HOLLOW METAL ® II HT HE IGHT I NSUL INSULATION II-� KIT KITCHEN L LP LOW POINT MO MASONRY OPENING MTL METAL OL NEC, NECESSARY N I C NOT IN CONTRACT NO NUMBER NTS NOT TO SCALE OH OPPOSITE HAND OPG OPENING PL LAM PLASTIC LAMINATE PLBG PLUMBING CODE INFORMATION THIS PROJECT SHALL COMPLY WITH ALL APPLICABLE CODES AND CODE AMENDMENTS AS ADOPTED BY THE LOCATION ��A1� DRAM 11�G I PL PROPERTY LINE FROM OR161AL CONSTRUCTION DOCUMENTS: TOWN OF VAIL TO INCLUDE, BUT NOT BE LIMITED TO: PLWD PLYWOOD BUILDING TYPE: RESORT HOTEL 2010 INTERNATIONAL NATIONAL OE ELECTRICAL COPE DE BUILDING CONSTRUCTION: TYPE I-B 2012 UNIFORM PLUMBING CODE R RISER PRIMARY OCCUPANCY GLASS IFICATION: R-I 2012 INTERNATIONAL MECHANICAL CODE AR(:�,H I TECTUI�® AL RD ROOF DRA IN REFL REFLECTED 5PAGE TO BENCONVERTED AO.O COVER SHEET O Gl Rights s Reserved P.C. All Rights Reserved REa REQUIRED A2.1 FLOOR PLAN DIREGTOR`�' S`Y'MBOLS TOOFFIGES A2.2 REFLECTED CEILING PLAN REV REVERSE This document and the ideas A&.1 DOOR SCHEDULE, WALL TYPES and designs incorporated RGH ROUGH ARCHITECT ROOM 115 SYMBOL / �GY TO ROOM I�115t� S - p herein,as an Instrument of • _ professional service,is the 6WATHMEY PRATT SCHULTZ LINDALLARGHITECTS, P.G. " s �_� property aGPSLAr,Istects,P.C., RO ROUGH OPENING 1000 SOUTH FRONTAGE ROAD WEST -� and is not to be used,r whole or In part,for any other project RM ROOM VAIL, CO 81657 (q70) 476-1147 FAX (q70) 4�6-1612 ROOM NAME/NUMBER CEILING HT (APPROX I MATE) _ .a�F j M E G HA N I CA L without the written authorization Of Henry R.Pratt SEAL SEALANT OWNER E N PE OL SHT SHEET SONNENALP RESORT ----— / ' -� _ NONE _ _ MI.O MECHANICAL L CAE DS, S GS, GONTR 20 VAIL ROAD FLOOR - BASE -WALLS CEILING } - { MI.I MECHANICAL SCHEDULES $ DETAILS SIM SIMILAR VAIL, CO 8165 (q70) 4-76-5656 '- _ . GO EXIST GONG - NONE GP TEXTURED GYP BRD - NONE M2.0 MECHANICAL- HVAG PLAN 50G SLAB ON GRADE GENERAL CONTRACTOR F - M2.I MECHANICAL- HVAG PIPING PLAN Date. P SPECIFIED TO BE DETERMINED VCT VINYL COMP TILE V VINYL GT FIRE-TAPED GYP-BRD AG SUSPENDED ~ 31 JULY 2015 S EG D S EG ACOUSTIC 4q- Q Iq AUGUST 2015 SPECS SPECIFICATIONS - dw STD STANDARD MECHANICAL ENGINEER - STOR STORAGE 245 ENGINEERS �, - I °� 245 CHAPEL PLACE, SUITE 200 ~t ;_ ' 9 E L E C I R I(�,A L de AVON, GO 81620 (q70) q4q-6000 FAX (q-70) q4q-Ig5q h _ EI.O ELECTRICAL LEGEND, SPECS, DETAILS ELECTRICAL ENGINEERS M-E ENGINEERS E2.0 ELECTRICAL- POWER $ SYSTEMS PLAN GHTING PLAN T TREAD 245 CHAPEL PLACE, SUITE 200 � ' �' V� F-2.1 ELECTRICAL- LI , TEL TELEPHONE AVON, CO 81620 (q-70) q4q-6000 FAX (q'70) q4q-Ig5q GRAPHIC, KEY TO MATERIALS DRAWING SYMBOLS THK THICK/THICKNESS }; NI f- CO , TYP TYPICAL III-1111=1111 EARTH !!L111 GMU ELx -x FLOOR OR REVISION 1111-1111- T,o. SPOT ELEVATION SYMBOL T ; T.O.D. TOP OF DECKING co 7.0.5. TOP OF SLAB 71711, STONE PLYWOOD O DOOR NO. - 20 $ � INTERIOR ELEVATION 33 Ae.0 SYMBOL 4 U.N.O. UNLESS NOTED OTHERWISE �� 0 WINDOW TYPE _ ,'. . CONCRETE GATT INSUL N x SECTION NO. A 7.0 IMAde TAKEN"RDM XX HOLLOW MTL SHEET NO. EAREARTH+ V VARIES � SOD/GRASS � RIGID INSUL'N X DETAIL NO. W/ WITH R6H STUD WALL TYPE A1.2 SHEET NO. Sheet Number w/0 WITHOUT WC WATER CLOSET STEEL ® FINISH WOOD CON O R D CONTOUR W/D WASHER/DRYER RECEIVED B David Rhoades at 2:02 m Aug 1 2013 AO . 0 WT WEIGHT Y P � 9 COVER SHEET :,��.�h�.�.-.. =:. �' �,�. -: � . O C14 CD CID FAN COIL UNIT SCHEDULE OR EQUIVALENT 36" HEATING COIL DATA COOLING COIL DATA ELECTRICAL OPER. UNIT MANUFACTURER& TOTAL O.A. ESP DIMENSIONS C: CU - r NO TURNING VANES SERVICE LOCATION HP TOTAL AIR SIDE WATER SIDE TOTAL AIR SIDE WATER SIDE DATA WT. REMARKS � V M O (TYPICAL) TAG MODEL NO. CFM CFM (IN) MBH EDB(°F) LDB (°F) APD EWT(°F) LWT(°F) GPM PD (FT) SOLUTION MBH EDB(°F) EWB(°F) LDB(°F) LWB (°F APD EWT(°F)LWT(°F GPM PD (FT) SOLUTION V/PH/Hz L(IN) H(IN) W(IN) (LBS) i :,��.�h�.�.-.. =:. �' �,�. -: � . :,��.�h�.�.-.. =:. �' �,�. -: � . O TYPICAL 8'0"CEILING ELECTRICAL LEGEND ELECTRICAL SPECIFICATIONS N 00 (NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT) 14. ELECTRICAL DEVICES L. All cable hangers shall be no more than 48"apart. Contractor shall be U) Nl/` I , familiar and install in accordance with all applicable codes and standards, 4_0 0 8 A. General Requirements A. Convenience receptacles will be 20 amp, commercial grade an RECESSED OR SURFACE DOWNLIGHT ABBREVIATIONS including NEC, EIA/TIA 568,569 and 606, and federal, state and local codes. decora style. Finish per owner or architect. g N � � Q-1 WALL MOUNTED LIGHT FIXTURE Care must be taken to ensure cables are not kinked, bent beyond limit, _ U N AC -ABOVE COUNTER Y �+ U — (D RECESSED FLUOR.LIGHT FIXTURE AFF -ABOVE FINISHED FLOOR 1 SCOPE: Furnish all materials and labor required to execute this work B. Light switches will be 20 amp, commercial grade, overloaded, over-cinched, crushed, improperly untwisted, etc. U Aa AFG ABOVE FINISHED GRADE as indicated on drawing and as specified as necessary to complete the decora style. Finish per owner or architect. W U U 00 , AHJ -AUTHORITY HAVING JURISDICTION (n � (/1 �� Aa SURFACE FLUOR.LIGHT FIXTURE contract. Electrical work shall include, but not limited to, these major M. No exposed wiring will be accepted unless approved in writing by the U) in C � AL -ALUMINUM C. Dimming switches will be a minimum of 600w or as noted. MAIN CIRCUIT BREAKER& FIXTURE DESIGNATIONS: CU -COPPER items: U O ti Provide decora style, finish per owner or architect. engineer. Cabling shall be in the wall, above the ceiling or where exposed, Q �p � O r'1 BRANCH CIRCUIT BREAKERS UPPER CASE-FIXTURE TYPE EC -ELECTRICAL CONTRACTOR enclosed within cable trays, raceways or conduit, as specified. i LOWER CASE-SWITCH DESIGNATION EM -EMERGENCY A. Complete wiring system for new lighting and power as shown, D. All mounting heights will conform to ADA guidelines. Typical receptacle U Q MAXIMUM MOUNTING HEIGHT p 9 Y 9 9 p 9 9 9 YP p GC -GENERAL CONTRACTOR including new anelboards, new conduits, new wires, new wiring heights will be+18"AFF and switch heights will be +46"AFF SHADING ON FIXTURE INDICATES EMERG.BATTERY BACKUP N IS 79", MINIMUM IS 18". GND -GROUND g P g 9 9 N. All cabling shall be bundled and properly secured and terminated. FLUORESCENT STRIP FIXTURE GFI GROUND FAULT INTERRUPTER devices, new control devices, etc. for a complete lighting and unless noted otherwise. 0) 0 0 N X 0 ���� MC MECHANICAL CONTRACTOR E0 $91 �� TRACK LIGHT AS NOTED OR SCHEDULED NIC NOT IN CONTRACT and power system. E. Provide GFI type receptacles at kitchens, bathrooms, O. The warranty set forth for this system shall consist of a full three (3)years �_ (6 U io NL NIGHT LIGHT •L. +� WALL WASHER a. Complete feeders Installation as required for new and/or garages, exterior etc. as required by code. from the date of project completion. The contractor warrants the system to be N � •M NTS NOT TO SCALE p feeder(s) q tamper F. Provide tam roof receptacles at all residential free of defects of workmanship or products and will inspect and repair the O U oo �Q POLE-MOUNTED FIXTURE OS OCCUPANCY SENSOR electrical apparatus as shown on single line diagram and p p p U O > C? PC PLUMBING CONTRACTOR system during this warranty period at no additional cost to the owner. The J i POST(BOLLARD)FIXTURE drawings. areas as required by code. Q N N d REF -REFERENCE warranty period shall begin at the point of system acceptance or beneficial C Lf) U IS= STEP LIGHT UG -UNDERGROUND 15. SUPPORT — _ 2 06 06 a) 5 o UNO UNLESS NOTED OTHERWISE b. Complete branch circuit wiring required for the connection of use,whichever comes later. �� F-(IJ® CEILING OR WALL MOUNTED EXIT LIGHT Ca CD 00 � p UTP UNSHIELDED TWISTED PAIR emergency lighting and exit signs to existing emergency stand A. Support all electrical equipment independent of accessible ceilings as D r—T EMERGENCY BATTERY LIGHTS WP WEATHER PROOF by power system. required by NEC. W 2 LIJ � �I*vO TV DUPLEX RECEPTACLE @ 18"UNLESS NOTED XFMR -TRANSFORMER _ +18" -MOUNTING HEIGHT TO CENTERLINE U J O c) = Zo 0= DOUBLE DUPLEX RECEPTACLE @ 18"UNLESS NOTED OF DEVICE AFF OR AFG 2. Complete provision, installation and connection of lighting fixtures, 16. ELECTRICAL BOXES N ti FIRE ALARM SYSTEM exit signs and lamps as specified and as shown on drawings. A. At fire rated wall space electrical boxes at opposite sides of the wall w 07 Q• FLUSH FLOOR DUPLEX RECEPTACLE FINISHED FLOOR ® SPECIAL OUTLET AS NOTED E-0-0 GENERAL NOTES ALL SHEETS FACP FIRE ALARM CONTROL PANEL 3. Fire alarm system will be by electrical contractor. no less than 24" horizontal distance. � Q__ DUPLEX RECEPTACLE HALF-SWITCHED @ 18"UNLESS NOTED ANN FIRE ALARM ANNUNCIATOR PANEL B. When phone, TV&power receptacles are shown on plan next to each other. U N O C:4. Complete connection of HVAC/Plumbing motor(s), water heater(s), (� U Op U POP-UP RECEPTACLE Q FIRE ALARM PULL STATION Locate respective receptacles next to each other on site with no more THE ELECTRICAL CONTRACTOR WILL PROVIDE A WALK THROUGH WITH THE '— O equipment, etc.furnish by mechanical -refer to both electrical and � � � TYPICAL DEVICE TELE-POWER POLE E31 ALARM HORN OR SPEAKER than 1"seperating cover plates. OWNER/ARCHITECT PRIOR TO FINAL ROUGHIN AS FOLLOWS: +-+ MULTI-OUTLET PLUG STRIP ❑41 and mechanical drawing for scope and work and additinal infor-COMBINATION HORN/STROBE OR SPEAKER/STROBE • CONFIRM ALL LOCATIONS FOR LIGHT SWITCHES; ADD THREE WAYS IF - mation. FOUND NECESSARY. (D 00 U J® JQ J H JUNCTION BOX IN FLOOR,CEILING OR IN WALL •H THERMAL HEAT DETECTOR B. Cat 6 Wiring Requirements 2 Q J MOUNTING HEIGHTS REVIEW RECEPTACLE LOCATIONS; MOVE AS REQUIRED. PROVIDE L M V COMPUTER/TELEPHONE OUTLET IN FLOOR OR WALL •1 SMOKE/IONIZATION DETECTOR 5. Provide grounding and bonding Facilities. 00 B TELEVISION OUTLET •P PHOTOELECTRIC SMOKE DETECTOR A. The cabling for voice and data must be continuous, home run, non-spliced, UNIT PRICING IF ADDITIONAL RECEPTACLES ARE REQUIRED. TELEPHONE BACKBOARD •H/P HEAT/PHOTOELECTRIC SMOKE DETECTOR 6. Complete all electrical demolition as required. 500 Mhz or better category 6, 4 pair UTP as applicable. Acceptable • REVIEW RECEPTACLE LOCATIONS AT COUNTERS AND CONFIRM IF m NOT TO SCALE CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING THOSE RECEPTACLES SHOULD BE ABOVE COUNTER OR BELOW. MOVE NOTES: ��R DUCT DETECTOR manufacturers include: Berk-Tek, Belden, Lucent or equivalent. AS REQUIRED. 0 CIRCUIT HOMERUN FO SPRINKLER SYSTEM FLOW SWITCH 7. Core drilling and patching of existing building structure required for IN GENERAL CONFIRM POWER AND LIGHTING REQUIREMENTS. THE 0- 1. HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX — — — CONDUIT RUN BELOW FLOOR OR GRADE I■+ SPRINKLER SYSTEM TAMPER SWITCH electrical work. Core drilling shall follow Building Standard procedures B. Data cable will be colored blue. Voice cable will be colored white. UNLESS NOTED OTHERWISE. ELECTRICIAN SHOULD BE PREPARED TO REWORK SOME DEVICE LOCATIONS. ] CONDUIT STUB-UP-CAP&MARK �- STROBE and contractor shall have written approvals from building owner prior SIGNIFICANT REWORK SHOULD BE FLAGGED AND UNIT PRICING PROVIDED 2. DEVICES ABOVE DOORS SHALL BE CENTERED BETWEEN TOP to start of an work. C. The terminations at the station locations must be Category 6, T568B (AT&T) LIGHT SWITCH AT 46"UNLESS NOTED QD SMOKE/FIRE DAMPER CONNECTION Y AND WRITTEN AUTHORIZATION FOR ADDITIONAL COSTS APPROVED PRIOR OF DOOR TRIM AND CEILING LINE. modular RJ-45, 8 pin, 8 conductor, Hubbell, Leviton, or lucent or equivalent SUBSCRIPTS: 1. REMOTE INDICATOR LIGHT TO PROCEEDING. i oO REG/,S. 3. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS 2=2-POLE SWITCH 8. Test of entire system and work. jacks, match faceplates to power, color coded for voice and data, match to 4 7 AND NOTED ON ELECTRICAL FLOOR PLANS SHALL GOVERN 3=3-WAY SWITCH SECURITY SYSTEM cable. Outlets will be securely held in place. 0 O ��� 4=4-WAY SWITCH 0 OVER THOSE SHOWN ABOVE. M=MOTION-OPERATED SWITCH 9. Operating, Maintenance and identification instructions manuals, if U a 4. FOR CEILING HEIGHTS HIGHER THAN 72", INSTALL FIRE ALARM K=KEY-OPERATED SWITCH Dc CONTACT DOOR SWITCH IN JAMB OR HINGE any. D. Wall mounted patch panels will be provided. NOTIFICATION AUDIO AND VISUAL APPLIANCES AT 80"AFF TO=THERMAL OVERLOAD SWITCH PCKI INTRUSION MOTION DETECTOR AS SPECIFIED,CORRIDOR/ROOM NEW WORK CLOUDED n> OS=OCCUPANCY SENSOR(SEE SCHEDULE) C OR R 10. PERMITS AND FEES: Obtain and pay for all necessary permits, inspec- OTHERWISE INSTALL AT 6" BELOW CEILING. E. All cables will be labeled with self-laminating labels at each cable end, at each PANEL 10 DIMMER SWITCH W/WATTAGE tions, examinations and fees or charges necessary for execution and 5. MOUNTING HEIGHTS PER IBC 2012 ND ADA CODES �K KEY-OPERATED ACCESS SWITCH patch panel location, and each wall/floor faceplate that has wiring installed. H1A Q 0 PUSHBUTTON CONTROL STATION 'C:= completion of electrical work. 1 � SURVEILLANCE CAMERA Coordinate numbering scheme with owner. �SIONN_ PC PHOTOELECTRIC CELL TS TIME SWITCH DISTRIBUTION EQUIPMENT SYMBOLS 11. REGULATIONS AND CODES: F. Provide plenum rated cable when required by article NEC 300-22. QT THERMOSTAT AT 60"UNLESS NOTED DISCONNECT SWITCH A. Applicable codes: National Electric Code (2008) eDIVISION 15 EQUIPMENT FUSES Conform to the prevailing edition and amendments thereto of the G. All cable above the ceiling must be tied and properly supported with FOOD SERVICE EQUIPMENT CIRCUIT BREAKER Town of Vail Electrical Code, pertinent NFPA publications independent hangers. Cable"draped"across ceiling tiles is unacceptable. In AIC <10 OCCUPANCY SENSOR(SEE OCCUPANCY SENSOR SCHEDULE) CURRENT TRANSFORMER and to the requirements of Federal, State or other City agencies the case of"hard"drywall ceilings, adequate support shall be accomplished TRANSFORMER having jurisdiction. where reasonably possible. COMMUNICATION SYSTEM ^^/\A (4#4/0 CU, 1 #4 CUG)2.5"C ED METER 12. SHOP DRAWINGS AND SUBMITTAL: H. Route cables so as not to exceed 90 meters in length. Bidder will identify any OR(4#300 MCM AL, 1 #2 ALG)3"C SQ QS I SPEAKER IN CEILING OR WALL ® MAGNETIC MOTOR STARTER cable runs exceeding 90 meters and provide solution to meet the 90 meter A. Contractor shall submit shop drawings for engineer review and approval. 9 p �V I VOLUME CONTROL AT 60"UNLESS NOTED [-h DISCONNECT SWITCH requirement. LOCATE ADJACENT TO OM < -I MICROPHONE OUTLET IN FLOOR BOX OR WALL E-Mi-1111 PANELBOARD OR LOAD CENTER,FLUSH OR SURFACE MOUNTED B. Shop drawing submittal shall include: EXISTING PANEL H1. 1. Lighting fixtures. C CALL-IN SWITCH SWITCHBOARD,MOTOR CONTROL CENTER OR DISTRIBUTION BOARD I. All wiring shall be protected from moving mechanical or physical contacts. O © PROGRAM BELL ❑T TRANSFORMER 2. Panelboard(s). Cabling shall be free from tension at both ends, as well as through out the Q INTERCOM �1i GROUND length of the run. Splices and bridge taps with cabling are strictly prohibited. Q CLOCK D CIRCUIT BREAKER 13. CONDUIT AND WIRE: Wiring is to be run in cable tray and conduit where specified. U) Q AMPLIFIER QM MOTOR OUTLET A. CONDUCTOR SIZES AND TYPES: For sizes#1/0 AWG and larger, use J. All connections of twisted wiring shall be made in such a way as to minimize _ ATS AUTOMATIC TRANSFER SWITCH coppper THW or aluminum XHHW. For sizes#1 AWG and smaller, use only O the extent in which each twisted pair is unraveled at the point of its physical copper wire with 600V insulation,types TW, THHN, or THW-stranded in termination. No more than .5 inches of exposed untwisted pairs shall be Q sizes#8 and larger, solid in sizes#10 and smaller. Control wiring shall be#14, present at these locations. stranded. Use type THHN for wires entering or passing through fluorescent lighting fixtures. All motors shall be wired with copper conductors only. K. Cable bends shall be no less than eight times the cable diameter or 1.00". B. MC cable permitted per local codes. Run hard pipe from panel to local Cables are to be kept a minimum of 6"from power lines, electric motors, J 1. WALL ASSEMBLY -THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY junction box, and run MC cable from junction box to device. fluorescent fixtures or heat generating devices. O 225/3 W SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL J 1A U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND I I O 3 SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS-WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 HR FIRE RATED PANEL H1 MATCH EXISTING A U Q ASSEMBLIES)OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 PROJECT:SONNEALP OFFICE IT ENGINEER: SOH BREAKERS. MM) LUMBER SPACED 16 IN. (406 MM)OC WITH NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER END PLATES PROJECT#: 13047 VOLTAGE: 120/208V,3P,4W AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM)WIDE BY 1-3/8 IN. (35 MM) DEEP MOUNTING: RECESSED MAINS: 225A MLO _ CHANNELS SPACED MAX 24 IN. (610 MM)OC. TYPE:SIEMENS P1 AIC: 10K EXISTING GEAR "MS B" w O Q B. GYPSUM BOARD* - NOM 1/2 OR 5/8 IN. (13 OR 16 MM)THICK, 4 FT. (122 CM)WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER DESCRIPTION A PHASE C BKR P CIR CIR P BKR A BHASE C DESCRIPTION LOAD CALCULATIONS- 2500A, 120/208V, 3P7 4W Q > TYPE AND SHEET ORIENTATION DESIGN IN THE UL FIRE RESIST ANCE DIRECTORY.SPECIFIED INDIVIDUAL MAX DIAM OF OPENING 0 SERIES ING IS 26 IN. (60 MM) HIGHEST DEMAND: 317A FC-1 912 20 1 1 2 1 20 1000 COPPIER RECEPTACLE 65kA1 C > LIGHTING 975 20 1 3 4 1 20 720 OFFICE RECPETACLE PANEL H1A NEC DEMAND: 41A 2. THROUGH PENETRANT -ONE CONDUIT INSTALLED EITHER CONCENTRICALLY OR TOTAL DEMAND: 354A LIGHTING 1200 20 1 5 6 1 20 540 OFFICE RECPETACLE ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR OFFICE RECPETACLE 720 20 1 7 8 1 20 720 OFFICE RECPETACLE MSB CAPACITY: 2500A TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM) (POINT CONTACT)TO MAX 2 IN. (51 OFFICE RECPETACLE 540 20 1 9 10 1 20 720 OFFICE RECPETACLE MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. OFFICE RECPETACLE 720 20 1 11 12 1 20 720 OFFICE RECPETACLE ELECTRICAL ONE-LINE D O THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: OFFICE RECPETACLE 720 20 1 13 14 1 20 720 OFFICE RECPETACLE 1 B A. CONDUIT- NOM 6 IN. (152 MM) DIAM (OR SMALLER)STEEL CONDUIT OR NOM 4 IN. (102 MM) DIAM OFFICE RECPETACLE 900 20 1 15 16 1 20 720 OFFICE RECPETACLE NO SCALE— 0 (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING 9� FC-2 912 20 1 17 18 0 NOTE: PROVIDE SHORT CIRCUIT BRACING TO MEET REQUIREMENTS NOTED U)3. FILL,VOID OR CAVITY MATERIAL* - CAULK OR SEALANT - MIN 5/8. 1-1/4,1-7/8 AND 2-1/2 IN. 0 119 20 0 AT ONE-LINE, NOTED AS "AIC AVAILABLE". SERIES RATED COMBINATION _L__/V ..J_LJ (16, 32, 48 AND 64 MM)THICKNESS OF CAULK FOR 1, 2, 3 AND 4 HR RATED ASSEMBLIES, 0 21 22 0 ACCEPTABLE, SUBMIT MANUFACTURER'S SERIES RATINGS WITH SHOP RESPECTIVELY,APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. MIN 1/4 IN. (6 MM) 0 23 24 0 DRAWING REVIEW. DIAM BEAD OF CAULK APPLIED TO GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACT 0 25 26 0 LOCATION ON BOTH SIDES OF WALL. 0 27 28 0 THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING 0 29 30 0 AEC PROJECT #: 13047.00 Max Pipe or Conduit F Rating T Rating OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED,AS SHOWN IN THE FOLLOWING TABLE. 0 31 32 1 0 Dian in. (rich) Hr Hr THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE 0 33 34 0 ROUTE WIRE AT CEILING PARALLEL OR 1 (25) 1 or 2 0+, 1 or 2 PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, 0 35 36 0 PERPENDICULAR TO STRUCTURE. SECURE DATE: ISSUE: 1 (25) 3 or 4 3 or 4 AS TABULATED TO THE LEFT. 0 37 38 0 TO STRUCTURE AT 4' INTERVALS OR LESS. 0 39 40 0 05-24-13 PROGRESS REVIEW 4 (102) 1 or 2 0 3M COMPANY-CP 25WB+ CAULK OR FB-3000 WT SEALANT, 0 41 42 0 06-03-13 MECH. PROGRESS SET 6 (152) 3 or 4 0 *BEARING THE UL CLASSIFICATION MARKING STUB UP TO ABOVE — 06-07-13 CD SET 12 (305) 1 or 2 0 LOAD CALCULATION SUMMARY ACCESSIBLE CEI NG CALCULATED POWER FACTOR: +80-AFF 07-26-13 OWNER REQUESTED PENETRATION THROUGH A FIRE-RATED WALL 0.98 REVISIONS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS 08-13-13 REVISIONS 1 NOT TO SCALE LIGHTING/CONTINUOUS 2175 6 2719 8 STRUCTURED CABLE 11 RECEPTACLES 9460 26 9460 26 DISTRIBUTION PANEL Drawn By: Checked By: MECHANICAL 1824 6 2052 7 + KITCHEN 0 0 0 0 80"AFF LIE SOH (2#CAT 6)3/4"C TOTAL 13459 38 14231 40 PLENUM RATED WIRE WHEN REQUIRED #6 ELECTRICAL PPULLWIRE 4"C V LEGEND MECHANICAL SCHEDULE (1) RJ-11 & (1) RJ-45 MAIN TELE/DATA IN SINGLE GANG TAG DESCRIPTION LOAD VOLTAGE PHASE WIRE SIZE (CU) CONNECTION CIRCUIT BREAKER REMARKS ROOM BOX AT 18"AFF LINO SPECS & THERMAL TELEPHONE ONE— COLD WATER PIPE TELEPHONE/ FC-1 FAN {COIL #1 (2)114 HP 120 1 (2 #12, 1 #12G) 1/2 C OVERLOAD 20A1 P DETAILS THERMAL LINE DIAGRAM- COMPUTER ROUGHIN- SCALE: NONE FC-2 FAN COIL #2 (2)1/4 HP 120 1 (2 #12, 1 #12G) 1/2"C OVERLOAD 20A1 P NO SCALE NOTE: VERIFY ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. 100 1 of 3 ®COPYRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS, INC. O N CO 00 W O U co r > C0000 STgNDP �00 � � � -T C: m 0 ti O � OQO � N � o U E H1A-15 101 T �, � `! ° Fu O / a� J Q N N U • 06 F 06 o00 N Lu w L �j � J2o (a w Cl) ia:k Ak _ }' U N O C: 00 O FIFES _ `� ° o � � i � < co co H1A-11 Q X O (E) _ CONFERENCE H1A-4 °0 A SERVICES H1A-16 RESERVATIONS ° 0 0 0 H 1 A-13 H 1 A-12SS�o►�,a� \ ► ST/ H1A-14 � FIFES �--' 0 (� w Fc H1A-10 2 M TO FC Q M 10 1 w � LL H1A-2 H1A-17 H1A-1 J Q V_ J J - O COPIER U DIRECTOR H1A-6 A-`ALES OF SALES GOLD Z J J ASST CLU w O — Q IF El O U) STAIR #2 00 AEC PROJECT #: 13047.00 EXISTING RAMP DATE: ISSUE: TO GARAGE )FFICE 05-24-13 PROGRESS REVIEW H 1 A-7 06-03-13 MECH. PROGRESS SET 06-07-13 CD SET J r 07-26-13 OWNER REQUESTED REVISIONS 08-13-13 REVISIONS 1 Drawn By: Checked By: - LIE SOH N POWER & NORTH SYSTEMS POWER & SYSTEMS PLAN PLAN SCALE 1/4' = 1'-0" SCALE: 1/4" = 1'0" 2 ,00 2 of 3 ®COPYRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS, INC. 0 N CO 00 U) O 4-0 GENERAL NOTES: ; � o00 L Q a) .FUao 1. ALL LIGHT FIXTURES TAGGED A-EM TO BE CIRCUITED TO NON SWITCHED U) 0 U) c"t ON CIRCUIT EM3-7, 20A/1P. C C O Q O o N °' o > JQN � C: 06 U m 00 m L W STANpp W � w2o MATCH EXIT SIGN TO - EXISTING. (TYP) U .- coo 0 N A A A 101 T � � p � (A6 ® EM -EM A-E ® *A-EM U Q 0 d- Q x x o m O \ •A-EM\ q �\ q FILE q A A A A A A A A p0 RFC� T 0 o H;� H1A-3-PARTIAL�� A XA C S A A R SERVATI NS A c& a ® " � _ - 3 �A A A A A / A-E F l N E� \ \R E A,. LOCATE NEW PANEL H1A NEXT TO I-EM A A_ A R A A A EXISTING PANEL H1 . CONFIRM LOCATION A ST/ WITH OWNER PRIOR TO ROUGH-IN. L A A �=HlA53 q si os R A-E A A • A a-Fnn ®t A A A A A ui s A -E A '-A (D 0 A Lu A A A A A C) Q A UJ J CR *A EM A I I A A-E A SA , S GO O '°` ASS' A A CL J > 0 U A A A A Q U. U z LL J J H 1 A-3-PARTIAL � Q ui O • R A � / STAIR #2 A EM / / N z s A A z EXISTING RAMP 0 >> \> TO GARAGE _ A s, A O A " II�t A J 0 • i �>A 0 AEC PROJECT #: 13047.00 N DATE: ISSUE: 05-24-13 PROGRESS REVIEW 06-03-13 MECH. PROGRESS SET 06-07-13 CD SET 07-26-13 OWNER REQUESTED REVISIONS 08-13-13 REVISIONS 1 O C U PA N C Y S E N SOR SCHEDULE Drawn By: Checked By: LIE SOH TYPE DESCRIPTION MANUFACTURER CATALOG NUMBER MOUNTING REMARKS Os OCCUPANCY SENSOR SWITCH BRYANT MSD1000 SWITCH LU MI NAI RE SCHEDULE (OR EQUAL) TYPE DESCRIPTION MANUFACTURER CATALOG NUMBER MOUNTING NO LAMP VOLTS DIMENSIONS REMARKS OS1 OCCUPANCY SENSOR WITH SHARP CUTOFF BRYANT MSD1000C CEILING PROPERLY AIM UNIT TO COVER OFFICE A 1200 LUMEN 6" LED CAN LIGHT W/ HOUSIN COOPER HALO ML712827TUNVD010 -H750T RECESSED LED 120 6-3/16" H X5-3/4" W FINISH PER ARCHITECHT (OR EQUAL) LIGHTING NOTE: ALTERNATE EQUIVALENT LIGHTING PACKAGES ACCEPTED WITH ENGINEER'S REVIEW OF SUBMITTAL. OS2 OCCUPANCY SESNOR WITH NO CUTOFF BRYANT MSD2000C CEILING THE ELECTRICAL CONTRACTOR SHALL PROVIDE FIRE TENTING TO MAINTAIN FIRE RATINGS FOR ALL RECESSED FIXTURES LOCATED IN FIRE RATED ASSEMBLIES. (OR EQUAL) BACKBOXES FOR NON-IC RATED FIXTURES MUST HAVE 3" CLEARANCE BETWEEN FIXTURE HOUSING AND INSIDE SURFACES OF BACKBOXES. BACK BOXES FOR IC-RATED FIXTURES MAY BE TIGHT TO FIXTURE HOUSING. PLAN BRYANT R OCCUPANCY SENSOR 24V POWER AND (OR EQUAL, MUS MSCU ABOVE CEILING SCALE 1/4" = 1'-0" RELAY MATCH SENSOR) I NORTH NOTE: ALTERNATE EQUIVALENT LIGHTING CONTROL PACKAGES ACCEPTED WITH ENGINEER'S REVIEW OF SUBMITTAL. LIGHTING PLAN_ SCALE: 1/4" = 1'0" 2 ,01 3 of 3 ®COPYRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS,INC.