Loading...
HomeMy WebLinkAboutB13-0325 REV1 PLANS.pdf IV I. CD PANEL RM - EXISTING CD PROJECT:ROCKY MOUNTAIN CHOCOLATE FACTORY ENGINEER: SOH oo GENERAL NOTES: PROJECT#: 13063 VOLTAGE: 120/208V, 1 P,3W MOUNTING:EXISTING MAINS: 100A MLO 4-1 O TYPE:EXISTING AIC: 10K (A U)- L- C,4 T N 1. EXISTING LIGHTING AND SHOW WINDOW POWER TO REMAIN IN PLACE. PHASE PHASE Cu U (� O +�' � 2. REUSE EXISTING RECEPTACLES AS FIELD CONDITIONS PERMIT, REVIEW DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION - �> � Opp WITH OWNER. q� - U C� LTG EX 40 LTS�5W LAMPS 200 20 1 1 2 1 20 180 RECEPTACLE EXISTING C) 3. PROVIDE GFI TYPE RECEPTACLES AT ALL AREAS CONSIDERED AS U) U) u� LTG(EX)25 LTS�5W LAMPS 125 20 1 3 4 1 20 50 BATHROOM EF EXISTING � KITCHEN AREAS BY CODE. C: p= (D O , SHOW WINDOW LTG 900 20 1 5 6 1 20 180 RECEPTACLE EXISTING SPACE 600 20 1 7 8 1 20 400 AIR CURTAIN o O Q O FREEZER 600 20 1 19 10 1 20 984 ICE CREAM RECEPTACLES (3) 540 20 1 11 12 1 20 1360 1 POS (2) ® 70 DECORATIVE HOOD 600 20 2 13 14 1 20 720 REC WEST 3 &UC REF 0)±-- CV m 600 15 16 1 20 960 CANDYCASE C: -0 (D IL _ FUDGE COOKER 4513 50 2 17 18 1 20 960 CANDYCASE 11 4513 19 120 1 20 540 RECEPTACLES WEST(3) 2) U O RECEPTACLES EAST CTR 3 540 20 1 21 22 2 40 1925 AIR CONDITIONING J Q N CV ESPRESSO 1400 20 1 123 24 11925 �_ 06 L 0 125 26 0 , 0 27 28 0 U ® C9 00 ci 0 29 30 1 0 i W 0 31 32 0 0 33 34 0 ) J = O 0 35 36 10 W -r- C/) CA 0 37 38 0 0 39 40 0 -� CO � CU 0 41 42 0 V U U pp O Q' � � OL LOAD CALCULATION SUMMARY +-' Q CL U N CALCULATED POWER FACTOR: V Q 0 0.97 L CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS Q X LIGHTING/CONTINUOUS 325 2 406 2 O RECEPTACLES 2700 13 2700 13 m MECHANICAL 3900 22 4862.5 28 Q KITCHEN 17389 84 11303 54 0- TOTAL 24314 120 19272 97 O R G��l 0 . 4 29840 � • C') RM-22,24 PROVIDE 120V INTERLOCK FROM M BATHROOM EXHAUST FAN TO 0 CONDENSING MOTORIZED DAMPER. UNIT AT GARAGE PROVIDE 40A2P Q HOMERUN, (3#8 , O#10G)1"C. Z Wo I PANEL Q RM (E) M O TO 0 J RM-7 RM-9 O RM-11 U AC A Fk< .. RM-14 Cn < RM-12 RM-16 0 < > U SAC U RM-23 _ 0 0 Lu Lu O Lu RM-10 O SPRESSO U CN RM-18 2 RM-20 RM-17,19 AEC PROJECT #: 13063 50A2P RM-21 DATE: ISSUE: � '-FUDGE RM-13,15 COOKPOT M 08-06-13 PERMIT DECORATIVE AC HOOD 20A2P 08-16-13 PERMIT REVISION HOMERUN, (3#12 NSPLAY� , 08-22-13 REUSE (E) PANEL 2 , #12G)1"C. / VERIFY AC ELECTRICAL REQUIREMENTS EXISTING BASEBOAF: EXISTING BASEBOARD J Drawn By: Checked By: AIR CURTAIN INTERLOCK MOTORIZED SOH AEC RECEPTACLE DAMPER TO EXHAUST FAN ABOVE DOOR RM-8 ELECTRICAL NORTH PLAN ELECTRICAL PLAN_ SCALE: SCALE 1/4" = 1'-0" 200 2 of 2 0 COPYRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS, INC.