HomeMy WebLinkAboutB13-0350 04-03-2015 Inspection Request Re orting Page 1
3•58 �m Vail, CO - CitTO�
Requested Inspect Date: Monday,April 06 2015
Site Address: 223 E GORE CR�EK DR VAIL
unit 103
A/P/D Information
Activity: 813-0350 Type: COMBO Sub Type: ACOM Status: EXPIRED
Const Type: Occupancy: Use: M Insp Area:
Owner: SWITZERFAMILYLP
Contractor: ENCORE ELECTRIC INC. Phone: 303-934-1234
Description: add 20amp 240 volt breaker circuit and space heater
Reauested Inspection(s)
Item: 90 BLDG-Final Requested Time: 09:00 AM
Requestor: ENCORE ELECTRIC INC. Phone: 303-934-1234
Comments: 471-0
Assigned To: J DRA ON Entered By: JMONDRAGON K
Action: Time Exp:
_ `
�
��� �
� ( f� ,
l�V
���
�
Inspection Historv
Item: 90 BLDG-Final
REPT131 Run Id: 14876
Department of Community Development
75 South Frontage Road
' � Vail, CO 81657
TOWN OF VAIL ' . � �`�-� �� Tei: s�o-4�9-z�zs
�� www.vailgov.com
t� � � Development Review Coordinator
C
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm &sprinkler)
Project Street Address: Project#: �ii��� � �� ��_� �
223 Gore Creek Drive 103
DRB#:
(Number) (Street) (Suite#) �(� � � ���
g p Creekside Buildin Building Permit#:
Buildin /Com lex Name: g
Contractor Information Lot#: Block# Subdivision:
Business Name: EnCOre EleCtriC
Business Address:
PO Box 8849 Work Class: New(�) Addition ((�jj Alteration (Oj
City Avon State: C� Zip: $�620 Type of Building:
Single-Family�j Duplex�j Multi-Family(�j
Contact Name: R.J. Vik �
Commercial (�j Other�
Contact Phone: 970-949-9277
r vik�a encoreelectric.com Work Type: Interior
Contact E-Mail: 1•
I hereby acknowledge that I have read this application,filled out Valuation of
in full the information required,completed an accurate plot plan, Work Included Plans Included Work
and state that all the information as required is correct. I agree to Electrical �i Yes �)No �Yes �No �oo
comply with the information and plot plan, to comply with all Town
ordinances and state laws, and to build this structure according to Mechanical �Yes �)No QjYes �No
the town's zoning and subdivision codes, design review ap-
proved, International Buildin� and Residential Codes and other Plumbing �Yes �jNo �Yes �jNo
ordinances of the Town applicable thereto.
� � Building �Yes �No �Yes �jNo
/+ .�
X / � =�`�j� Value of all work being performed: $ 700
Owne�-JOvuner's epre"sentative Signature(Required) �value based on IBC Section 109.3&IRC Section 108.3�
�--- Electrical Square Footage
Applicant Information Detailed Scope and Location of Work: Add 20amp 240volt
Applicant Name: R. J. Vik breaker, circuit and space heater.
Applicant Phone: 970-949-9277 �� ��
Applicant E-Mail: rj.vik@encoreelectric.com
Project Intormation Peter Switzer/Creekside Building
Owner Name:
Parcel#:�! � ) � �� Z � L• L�U — + –
(For Parcel#,contact Eagl County Assessors O�ce at(970-328-8640 or visit
www.eaglecounty.us/patie) D
(use additional sheet if necessary
For Office Use Only; ~U� �v �013
Date Received:
Fee Paid: � (��`��'
Received From: TQW�I �F �l'A��.
Cash Check#
CC: Visa/ MC Last 4 CC # exp date:
Auth #
12-Mar-2012
� • � �
•
Please read and save these instructions.Read carefully before attempting to assemble,install,operate or maintain the product described.
Protect yourself and others by observing all safety information.Failure to comply with instructions could result in personal injury and/or
properiy damage!Retain instructions for future reference.
� �
a
ton eav u
. .
t ea
ters
ec
tr � c n �
Description C �L us
Dayton Heavy-Duty Electric Heaters are designed for continuous or intermittent use
in factories,warehouses, public buildings,stock rooms,service stations, any large or File#E154218
exposed areas,or additions.Can be installed for use in downflow or horizontal
applications.
FEATURES:
• Units 5 thru 15 kW are field convertible from single to three phase
• 24 volt low voltage control circuit is standard except on 3 and 5 kW 208,240R08,
and 277V units which have line voltage control
• Heavy-duty totally enclosed motors Figure 7
• Aluminum finned,copper clad steel sheath heating element
• Advanced inlet louver design draws cool air across heating element for more Unpacking
efficient operation Remove the heater from the box and
• Automatic reset linear thermal protector inspect it for any damage. If it appears
• Venturi outlet with large dynamically balanced fan blade to be damaged, immediately return.
• Heavy gauge die-formed steel housing Check the contents of the box to make
• Optional vertical and horizontal brackets available sure it contains one heating unit.
Specifications
���
. . -
�-�..u�1►. 2YU58* 3.02.2 10.2/7.5 240208 1 240/208 12.5/11.0 1/100 1600 350 800 27 12' •
2YU59 3.0 10.2 480 3 24 3.6 1/100 1600 350 800 27 12
2YU60* 3.0 10.2 277 1 277 11.0 1/100 1600 350 800 27 12
2YU61* 3.0 10.2 208 1 208 14.5 1/100 1600 350 800 27 12
2YU62* 5.0/3.7 17.0/12.6 240/208 1-3 240208 21.0/18.0 1/100 1600 350 800 45 12
2YU63 5.0 17.0 480 3 24 6.0 1/100 1600 350 800 45 12
2YU64* 5.0 17.0 277 1 277 18.0 1/100 1600 350 800 45 12
2YU65* 5.0 17.0 208 1-3 208 24.0 1/100 1600 350 800 45 12
2YU66 7.5/5.6 25.6/19.1 240208 1-3 24 31.3/27.0 1/30 1600 650 970 37 18
2YU67 7.5 25.6 480 3 24 9.0 1/30 1600 650 970 37 18
2YU68 7.5 25.6 208 1-3 24 36.0 1/30 1600 650 970 37 18
2YU69 10.0/7.5 34.125.6 240208 1-3 24 42.0/36.0 1/30 1600 650 970 49 18
2YU70 10.0 34.1 480 3 24 12.0 1/30 1600 650 970 49 18
2YU71 10.0 34.1 208 1-3 24 48.0 1/30 1600 650 970 49 18
2YU72 15.0/11.2 51.2/38.2 240208 3 24 36.1/33.3 1/20 1530 910 1640 52 35
2YU73 15.0 51.2 480 3 24 18.0 120 1530 910 1640 52 35
2YU74 15.0 51.2 208 1-3 24 72.0 1/20 1530 910 1640 52 35
2YU75 20.0/15.0 68Z/51.2 240208 3 24 48.0/41.2 1/10 1500 1320 2060 48 41
2YU76 20.0 68.2 480 3 24 24.0 1/10 1500 1320 2060 48 41
3END3 25 85.2 480 3 24 30 1/4 1600/1375 2100/1800 2100/2030 45/53 50
2YU77 30.022.5 102/77 240208 3 24 72.0/63.0 1/4 1600/1375 2100/1800 2100/2030 45/53 50
2YU78 30.0 102.3 480 3 24 36.0 1/4 1600/1375 2100/1800 21002030 45/53 50
2YU79 30.0 1023 208 3 24 84.0 1/4 1600/1375 2100/1800 21002030 45/53 50
3END4 40 136.4 480 3 24 48 12 1524/1420 30002600 32602900 49/42 60
2YU80 50.0/37.5 170/127 240/208 3 24 120.4/104.2 12 1525/1420 3000/2600 32602900 53/61 60
2YU81 50.0 170.5 480 3 24 60.2 12 1525/1420 30002600 32602900 53/61 60
(*)These models are wired for direct line voltage control.
�
Form 555542 Printed in�hina MAR053 . � �
09663 5/0$
0306/087NCPVP part No. 5200-2733-005
PPD 11697
**************************+****************+********************�**�************************
TOWN OF VAIL, COLORADO Statement
**************************************************************+*****************************
Statement Number: R130001398 Amount: $19.24 09/09/201312:01 PM
Payment Method:Credit Crd Init: CG
Notation: visa elizabeth
obrien
-----------------------------------------------------------------------------
Permit No: B13-0350 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-082-1200-1
Site Address: 223 E GORE CREEK DR VAIL
Location: unit 103
Total Fees: $224 .35
This Payment: $19.24 Total ALL Pmts: $19.24
Balance: $205. 11
*******************************�**************************+*********************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300 PLAN CHECK FEES 19.24
-----------------------------------------------------------------------------
"���-S I � - O �f�9
TOWN OF VAIL '
75 South Frontage Road West Community Development Department
Vail. Colorado 81657 970.479.2138
vailgov.com 970.479.2452 fax
Certificate
of
Non-Compliance
03/03/15
Switzer Family LP
12970 E. Cape Horn Dr
Tucson, AZ 85749-5704
Dear Owner/Agent,
A certificate of non-compliance is hereby filed in the Town of Vail
permanent records for the property located at 223 E Gore Creek Dr
unit 103 with the following action:
On 08/26/2013 permit B13-0350 was applied for at this office for electrical work. This permit
has expired per section 105.5 of the International Building Code 2012 edition. The Town of Vail
cannot verify code compliance and the structure has not received a final approval for work
authorized. A hold on the approval of any future projects for this property is hereby ordered until
the aforementioned permit is resolved with this office.
Sincerely,
Martin A. Haeberle
Chief Building Official
Department of Community Development
0 75 South Frontage Road
TOWN OF VAIL ' Vail, CO 81657
Tel: 970.479.2128
www.vailgov.com
Development Review Coordinator
TRANSMITTAL FORM
Use this form when submitting additional information for planning applications or building permits.
This form is also used for requesting a revision to building permits. A two hour minimum building review
fee of$110 will be charged upon reissuance of the permit.
Application/Permit#(s) information applies
to: Attention: ( ) Revisions
_ O O ( ) Response to Correction Letter
T attached copy of correction letter
Deferred Submittal
Other
Project Street Address:
(Number) (Street) (Suite#)
Building/Complex Name: Description of Transmittal/List of Changes, Items Attached:
1 Z_0A D CAt_cjk T.LAl,-5
Applicant Information
A-1/e L
(architect, contractor, owner/owner's rep)
Contact Name: F&Cv.&E E
Address:
City `State: Zip:
Contact Name: / t• y• G (use additional sheet if necessary)
Contact Phone: R7�-9�9— a�7 Building Permits:
Revised ADDITIONAL Valuations (Labor& Materials)
Contact E-Mail: (DO NOT include original valuation)
I hereby acknowledge that I have read this application,filled out Building: $
in full the information required,completed an accurate plot plan,
and state that all the information as required is correct. I agree to Plumbing: $
comply with the information and plot plan,to comply with all Town
ordinances and state laws, and to build this structure according ; Electrical: $
to the town's zoning and subdi ' Ion codes, design review ap-
proved,Internatio I Buil in nd Residential Codes and other Mechanical: $
ordinan o ow icable th
X , Total: $
Owner/Owner's Re resentative Signature(Required)
Date Received:
For Office Use Only: Crp 19 2013
Fee Paid: JCI
Received From:
Cash Check# TOWN OF VARL
CC: Visa/MC Last 4 CC# exp.date:
Authorization#
1
""'"IGERATiQ!1
Utility&Hazardous Location Heaters
Electric Utility Fan-Forced Heaters XDimplex
■Automatic thermal protection UTILITY 71°F temp.rise.Horizontal or vertical mount.Meets NEC I
■Built-in thermostat and OSHA requirements.When used for portable applications, FREEZE PROTECTION
UL and C-UL Listed. q P PP
Heating elements on Nos. requires optional cordset No.4E170. Rated for zero-clearance in concealed space
3UG73 and 2HAD1 feature No.4E169- or plenum applications.NEMA 12K control
Features High/Low Dimplex®-Compact,high-performance units are suitable box is gasketed to keep out moisture and
aluminized paint finish for heat selector and for basement,enclosed porch,garage,and workshop areas. dust.ETL Classified for U.S.and Canada.
corrosion resistance. fan-only option. Feature fan delay and include cord set for 240V single-phase
service,and ceiling/wall mounting bracket.
Amps Item $
Description kW BtuH Voltage AC H W D Brand No. Each
Utility,with Ceiling/Wall Mounting Bracket and Adjustable Louvers 5/4.1/3.3/2.5 17,065/14,215/11,365/8533 208 24.0/20.0/16.0/12.0 121h 14 111/4 Dayton 3UG74✓ 468.75
Utility,with Mounting Bracket and Adjustable Louvers 5/4.1/3.3 17,100/14,000/11,300/8500 240/208 209/17.4/13.9/1.17,Q 121/2 14 11,/4 Dayton 3UG73✓ 488.25
3.7/3.1/2.9 1.8 12,600/10,600/8500/6100 18.0/15.0/12. 0
Utility,with Ceiling/Wall Mounting Bracket(Predilled 5.0/3.3 3.7/2.5 17 060/11,26012.624/8530 208 240 20.8/13.8 17.8/12.0 16 21 8 Dayton 4E169 ✓ 553.50
Holes;Doubles as Handle or Floor Stand)
Utility,with Ceiling/Wall Mounting Bracket 5.0 17,065 240 20.8 11" 9' 9' Dimplex 140621✓ 355.00
Utility,with Ceiling/Wall Mounting Bracket 4.0 13,652 240 16.7 11' 9' 71/4' Dimplex 14C620✓ 250.25
Freeze Protection,with Mounting Bracket 2.5/1.95 8530/6650 240/208 10.7/9.42 121h 14 14 Dayton 2HOA1✓ 556.00
Item $
" ^• Description Brand No. Each
/ No. Asommin
No. No. • 14C620 Cord Set 6-Ft.,240V,For Use with 4E169 Dayton 4E170 79.15
3UG73 4E169 Replacement Thermostat,SPST,For Use w/3UG73,3UG74 Qmark 1ZKW6 39.00
4�f
t
Hazardous Location Electric Convection Heaters
•Class I Div.1 and 2 Groups B,C,and D Corrosion-resistant die-cast QMark®-Built-in mounting brackets.
•Min.height from floor:9" aluminum terminal box with Amps Overall(in.) Item $
Dayton®,8"QMark® knockouts for rigid metallic kW BtuH Voltage AC Phase H W D Brand No. Each
16-ga.steel cabinets with powder-coated conduit entry.ETL Listed for i 8 6143 205 18.7 o 1 in% 3s1h s1/4 Dayton 2GJE9 ✓ 1,327.00
finish.Sloped-top cabinet keeps objects US and Canada. 1.8 6140 208 8.7 1 20 42 9 Omark 3LA87 ✓ 1,513.00
from being set on top and restricting airflow. Note:Required contactors sold 1.8 6143 240 7.5 1 177A 391/2 81/4 Dayton 2CJF1 ✓ 1,327.00
separately on page 334.Required 1.8 6140 240 7.5 1 20 42 9 Qmark 3LA88 .1 1,513.00
3.6 12,286 208 17.3 1 17A 39h 8/4 Dayton 2CJF2 ✓ 1,711.00
thermostats sold separately on 3.6 12,280 208 17.3 1 20 42 9 Qmark 5NF11 ✓ 1,990.00
page 4572. 3.6 12,286 240 15.0 1 1714 391h 81/4 Dayton 2CJF3 ✓ 1,745.00
3.6 12,280 240 15.0 1 20 42 9 Omark 5NF09 ✓ 1,990.00
Dayton®-Mounting hard- 3.6 12,286 480 4.3 3 177/6 391h 81/4 Dayton 2CJF4 ✓ 1,745.00
ware included. 3.6 12,280 480 4.3 3 20 42 9 Omark 5NF10 ✓ 1,990.00
f,' 7.6 25,938 240 31.7 1 177/b 6314 81/4 Dayton 2GJF5 ✓ 2,624.00
4p 7.6 25,938 480 9.1 3 177/6 631h 81/4 Dayton 2CJF6 ✓ 2,677.00
Qmark 7.6 25,930 480 9.2 3 20 66 9 Qmark 5NF12 ✓ 3,055.00
Hazardous Location Fan-Forced Electric Unit Heaters 60,
6
■Class I Div.1 and 2 Groups C and D and Heavy-gauge steel cabinets.Mounting QMark®-Units feature automatic reset � '
Class II Groups E,F,and G with a T36 hardware must be field-supplied. thermal limit.Beige powder-coated finish.
ignition temp.code rating(329'F,1650C) Magnetic contactor and 24V control Amps Overall(in.) Item $
■3-phase,60 Hz,480V circuit transformer inside corrosion- kW BtuH AC CFM H W D Brand No. Each
■24V contactor resistant die-cast aluminum terminal 3.0 12,250 4.3 580 185/2 173/4 211/4 Dayton 2CJE1 ✓5,284.00
3.0 10,236 4.3 700 191/2 237/6 21 Omark 5NF04✓5,694.00
box with knockouts for rigid metallic 5.0 17,100 6.7 580 185A 17174 21114 Dayton 2CJE2✓5,516.00
conduit entry.ETL Listed for US and 5.0 17,060 6.1 700 191/2 237A 21 Qmark 5NF05✓5,944.00
Canada. 7.5 25,600 9.7 580 185/6 17374 211/4 Dayton 2CJE3 ✓5,809.00
7.5 25,590 9.7 840 191A 237/2 21 Qmark 5NF06✓6,259.00
rsti Note:Required remote thermostat or other control 10.0 34,150 12.7 1500 215/6 20V4 221/4 Dayton 2CJE4 ✓6,044.00
booegilif sold separately;see page 4572. 10.0 34,120 12.7 840 191/6 237A 21 Qmark 5NF01 ✓6,512.00
15.0 51,200 19.0 2450 255/6 243/4 24 Dayton 2CJE5 ✓5,976.00
1P Dayton®-Built-in manual reset 15.0 51,180 18.7 1450 25 277§ 21 Omark 5NF02✓6,795.00
capillary type thermal limit.Powder- 20.0 68,300 251 2450 255/o 243/4 24 Dayton 2CJE6 ✓5,892.00
coated gray epoxy textured finish. 20.0 68,240 24.8 1400 25 2776 21 Omark 5NF03✓7,075.00
Dayton 9 Y P Y 25.0 85,400 31.3 2450 255A 24V4 24 Dayton 2CJE7 ✓6,829.00
ABS Approved for marine and offshore
Qmark classifications.
Washdown, Fan-Forced Electric Unit Heaters q MARK
■3-phase,60 Hz,480V QMark®-Adjustable,stainless steel, Amps H W D Item $
16-ga.type 304 stainless steel louvered outlet grille rotates 900 to kW BtuH AC CFM (in.) (in.) (in.) Brand No. Each
Dayton housing. direct airflow up,down,left,or right. 3.3 11,200 4.0 400 191/4 12 18 Dayton 2CJF7 ✓2,422.00
5.0 17,100 6.1 400 193/4 12 18 Dayton 2CJFB ✓2,515.00
Dayton®-Units feature Units feature built-in thermostat,On/ 5.0 17,060 6.0 405 241h 15 131h Qmark 5NF17✓2,960.00
Off/Fan Only selector switch,and 7.5 25,600 9.1 400 193/4 12 18 Dayton 2CJF9 ✓2,463.00
3-position Off/Heat/Fan switch indicator light.Nonmetallic NEMA 4X 10.0 34,130 12.1 700 213/4 14 19 Dayton 2CJG1 ✓3,064.00
and built-in 24V transformer 10.0 34,120 12.0 700 28 151/6 171/4 Qmark 5NF13✓3,538.00
enclosure for element terminals,built- 15.0 51,200 18.1 700 211/4 14 19 Dayton 2CJG2✓3,658.00
and contactor,pilot light,ther- in controls,and junction box.Include 15.0 51,180 18.1 750 28 151/6 171/4 Omark 5NF14✓4,310.00
mostat,disconnect switch,and stainless steel bracket for wall or 20.0 68,260 24.1 1400 283/4 16 27 Dayton 2CJG3✓3,899.00
Qmark NEMA 4X control panel.ETL ceiling mounting.UL and C-UL Listed 25.0 85,325 30.1 1400 2884 116 1274 o yton 2CJG4✓4,848.00
Listed for U.S.and Canada. 25o 85,300 30.1 1800 32'/4 191h 211/4 Omark 5NF16✓5,537.00
• 30.0 102,390 36.1 1400 283/4 16 27 Dayton 2CJG5✓4,971.00
t Mounting H W D Item $
Description Type Fits KW (in.) (in.)(in.) For Use With Brand No. Each
AtxylaerlAs
Mounting Bracket Wall 3.3 to 15.0 201h 51h 51h 2CJF7,2CJF8,2CJF9,2CJG1,2CJH2 Dayton 2CJG6 262.00
Mounhno Bracket Wall 20.0 to 30.0 201h 514 514 2CJG3,2CJG4,2CJG5 Dayton 2CJG7 256.75
Find QUALITY BRANDS you can get only from Grainger on grainger.com/exclusivebrands 1-800-GRAINGER 4633
up R/eye
Panel Schedule
Volt 120/208 Enclosure NEMA Rating 1 Sub Feed Lugs N/A
Amp 60 Main Circuit Breaker — MLO Bussing Copper
Phase Mounting Type Surface
Circuit Breaker Load Load Phase Load Load Breaker Circuit
Number Trip Description VA VA Description Trip Number
1 O W A 4 A< A 2
3 O B oser O 4
5 �, `d 6
7 8
9 10
11 Z 12
13 AIR,A f 6 1/ 0 14
15 B C Q 16
17 18
19 20
21 22
23 24
25 A 26
27 B 28
29 C 30
31 A 32
33 B 34
35 C 36
37 A 38
39 B 40
41 C 42
Load A 0
Load B 0
Load C 0
Total 0