HomeMy WebLinkAboutB13-0358 specs REScheck Software Version 4.4.4
Compliance Certificate
Project Title: 1896 WGCD
Energy Code: 2012 IECC
Location: Vail, Colorado
Construction Type: Single Family
Project Type: New construction
Building Orientation: Bldg. orientation unspecified
Glazing Area Percentage: 22%
Heating Degree Days: 9248
Climate Zone: 6
Construction Site: Owner/Agent: Designer/Contractor:
1896 West Gore Creek Drive 1896 West Gore Creek Drive, LLC Michael Pukas
Vail,CO 81657 141 E Meadow Drive CO mpp design shop,inc.
Suite 211 PO Box 288
Vail,CO 81657 Gypsum,CO 81637
970-390-4931
michael@mppdesignshop.com
. � - . . . - .
Compliance:8.2%Better Than Code Maximum UA:512 Your UA:470
The%Better or Worse Than Code index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
. . •
� • • � �•
•
Ceiling 1:Cathedral Ceiling 2191 42.0 15.0 39
Wall 1:Wood Frame, 16"o.c. 3209 24.5 0.0 132
Orientation: Unspecified
Window 1:Wood Frame:Double Pane with Low-E 631 0.300 189
SHGC:0.00
Orientation: Unspecified
Door 1:Glass 86 0.300 26
SHGC:0.00
Orientation: Unspecified
Basement Wall 1:Solid Concrete or Masonry 1947 14.0 10.0 76
Orientation: Unspecified
Wall height: 12.0'
Depth below grade: 10.0'
Insulation depth: 10.0'
Floor 1:Slab-On-Grade:Heated 12 15.0 8
Insulation depth:4.0'
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2012 IECC requirements in
REScheck Version 4.4.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Michael
Name-Title Signature Date
Project Title: 1896 WGCD Report date: 08/26/13
Data filename: B:\mpp\My Documents\mpp design shop, inc\Projects\1304_Noble\REScheck\1896 WGCD.rck Page 1 of 1