HomeMy WebLinkAboutB13-0164 REV1 ComCheck.pdf COMcheck Software Version 3.8.0 Interior Lighting Compliance Certificate 2009 IECC Section 1: Project Information Project Type:Alteration Project Title :Vail Valley Medical Center-3rd Floor Clinic Construction Site: Owner/Agent: Designer/Contractor: 108 South Frontage Road, Suite#306 Vail,CO Section 2: Interior Lighting and Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B x C) Healthcare-Clinic 2900 1.0 2900 Total Allowed Watts= 2900 Area Category Exemption Qualifications Total Wattage Total Pre-Alt. #Fixtures Activity Area Pre-Ait. Post-Alt. Fixtures Repl./Added Section 3: Interior Lighting Fixture Schedule A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Waft. Healthcare-Clinic(2900 sq.ft.) Linear Fluorescent 1:F1,F3 and F4:46"T5 28W/Electronic 2 33 60 1980 Linear Fluorescent 2:F9:46"T5 28W/Electronic 2 3 56 168 Compact Fluorescent 1:F10:Triple 4-pin 26W/Electronic 1 12 26 312 Linear Fluorescent 5:F8:22"T5 14W/Electronic 2 2 28 56 Incandescent 1:F11:Incandescent 40W 1 4 40 160 Incandescent 2: 11:Incandescent 40W 1 4 40 160 Compact Fluorescent 2:12:Twin Tube 24/26/27W/Magnetic 3 1 54 54 T Total Proposed Watts= 2890 Section 4: Requirements Checklist Lighting Wattage: 1 Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 2900 2890 Passes Controls, Switching, and Wiring: 2. Daylight zones under skylights more than 15 feet from the perimeter have lighting controls separate from daylight zones adjacent to vertical fenestration. 3. Daylight zones have individual lighting controls independent from that of the general area lighting. Exceptions: Project Title: Vail Valley Medical Center-3rd Floor Clinic Report date: 08/29/13 Data filename: S:\BGProjects\8739.39 WMC Concierge Clinic\EngineeringiLighting\Calcs\ComCheck.cck Page 1 of ❑ Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device. ❑ Daylight spaces enclosed by walls or ceiling height partitions and containing two or fewer light fixtures are not required to have a separate switch for general area lighting. X4. Independent controls for each space(switch/occupancy sensor). Exceptions: ❑ Areas designated as security or emergency areas that must be continuously illuminated. ❑ Lighting in stairways or corridors that are elements of the means of egress. ❑ 5. Master switch at entry to hotel/motel guest room. ❑ 6. Individual dwelling units separately metered. 7. Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. 8. Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either controlling all luminaires,dual switching of alternate rows of luminaires,alternate luminaires.or alternate lamps,switching the middle lamp luminaires independently of other lamps,or switching each luminaire or each lamp. Exceptions: ❑ Only one luminaire in space. An occupant-sensing device controls the area. ❑ The area is a corridor,storeroom, restroom,public lobby or sleeping unit. ❑ Areas that use less than 0.6 Watts/sq.ft. 9. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: Jul Sleeping units,patient care areas;and spaces where automatic shutoff would endanger safety or security. ❑ 10.Photocell/astronomical time switch on exterior lights. Exceptions: ❑ Lighting intended for 24 hour use. 11,Tandem wired one-lamp and three-lamp ballasted luminaires(No single-lamp ballasts). Exceptions: Electronic high-frequency ballasts;Luminaires on emergency circuits or with no available pair. Interior . • Section 5: Compliance Statement Compliance Statement: The proposed lighting alteration project represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application.The proposed lighting alteration project has been designed to meet the 2009 IECC,Chapter 8,requirements in COMcheck Version 3.8.0 and to comply with the mandatory requirements in the Requirements Checklist. Name-Title Signature Date Project Title:Vail Valley Medical Center-3rd Floor Clinic Report date 08129113 Data filename:S:\BGProjects\8739.39 VVMC Concierge Clinic\Engineering\Lighting\Calcs\ComCheck.cck Page 2 of