Loading...
HomeMy WebLinkAboutA13-0058 Stamped approved plans REUSSWIG RESIDENCE -WEST UNIT ZONE LIST DEVICE # DEVICE TYPE LEVEL DESCRIPTION 001 HEAT DETECTOR LOWER GARAGE LEGEND: 002 CO DETECTOR LOWER MUD ROOM 003 SMOKE DETECTOR LOWER MUD ROOM AT FACP SYMBOL DEVICE MANUFACTURER PART MOUNTING GENERAL NOTES: 004 CO DETECTOR LOWER LOWER LIVING ROOM FACP Honeywell Vista-128BPT w/wireless 005 SMOKE DETECTOR LOWER LOWER LIVING ROOM Fire Alarm Control Panel interface & 7AH Batteries Mount on wall in manufacturer backbox 006 SMOKE DETECTOR LOWER LOWER BEDROOM 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN 007 CO DETECTOR MAIN MAIN LIVING ROOM ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE KP 008 SMOKE DETECTOR MAIN MAIN LIVING ROOM DEPARTMENT REQUIREMENTS AND NFPA 72. LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox 009 CO DETECTOR MAIN FAMILY ROOM 2. REFER TO MANUFACTURERS DATA SHEETS AND 010 SMOKE DETECTOR MAIN FAMILY ROOM INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION 0 Smoke Detector Honeywell 5193SD 4" square box 011 CO DETECTOR MAIN HALL OUTSIDE KIDS ROOM 012 SMOKE DETECTOR MAIN HALL OUTSIDE KIDS ROOM REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, �V) 013 SMOKE DETECTOR MAIN KIDS ROOM PROGRAMMING AND DEVICE OPERATION. ® system Sensor 5601P w--z J Heat Detector w/4193SN Addressable module 4" square box o o F_a o o mo 0 014 SMOKE DETECTOR UPPER MASTER BEDROOM a IY z vi 0F_ N- ~m 015 CO DETECTOR UPPER MASTER BEDROOM WWI 0 0<o w o 016 SMOKE DETECTOR UPPER HALL OUTSIDE MASTER H❑ Sounder System Sensor MHW Single gang box w VV)w 0 w o 017 MONITOR LOWER SPRINKLER WATERFLOW of Z Of 018 MONITOR LOWER SPRINKLER TAMPER m F 0 a 0 Z m a N o 019 Carbon Monoxide Detector Honeywell 580000 Single gang box o,1``w w o w W 02© 000v how zm aw 021 Vfwi�0TzH �-� z� 0 022 KB Knox Box jr w�!w U)- 0 a i=� a1w0w �= 000 023 LLJ 024 VrQ_°w>w oN LJ 0Q 025 Outside Horn/Strobe System Sensor P2RK Single gang box z w z o z� za U_ w°z THRU J�QZ}= o J oa 128 QWw_j wQ NU) Q 0 p U N N aaroN JJ om zzL) -mow Qa- z (�awUWNV ZQ Q Reusswig Residence -WEST UNIT M>_W'W m o z c�N �,z Ademco Vista 128 FACP o 0° of_j W 00 W V o z . Standby Nwwoiaz <De ZF Number of Current Total Current # w _ 3 16 PAIR, 1 DATA, 1 SOUNDER, 1 POWER a F w 0 z 0 N Q Device Type Devices (Amps) (Amps_) - �c�z a 0 N�wo Honeywell aa?cno_ww �0o a> Main FACP CPU 1 X 0.032 = 0.032 J W 0-J o J O W �w 4193SN Serial Interface 7 X 0.00{}15 = 0.00105 5192SD Smoke Detectors 9 X 0.00084 = 0.00756 EOLR H e 1 VISTAy 128 Carbon Monoxide Detectors 6 X 0.00025 - 0.0015 (4) (6) (9) (1) o n 6160 Keypad 2 X 0.04 = 0.08 c° It SUM COLUMN FOR STANDBY LOAD 0.12211 JAMPS EOLR BELL OUTPUT 00 1 Alarm Load KP O 't Number of Current Total Current n 0 '." Device Type Devices (Amps) (Amps) DIALER V 1 0 U o0) Main FACP CPU 1 X 0.032 = 0.032 DEDICATED 120V Z Q 4193SN Serial Interface 7 X 0.00015 = 0.00105 TELE LINES 0 5192SD Smoke Detectors 9 X 0.0196 = 0.1764 PO . Carbon Monoxide Detectors 6 X 0.00025 - 00015 LO 6160 Keypad 2 X 0.1 - = 0.2 SYSTEM ONE- LINE DIAGRAM MHW Sounder 4 X 0.066 = 0.264 U m Outside HornlStrabe 1 X 0.176 - 0.176 NOTE 1. NO T-TAPPING PERMITTED ON ANY CIRCUIT SUM COLUMN FOR STANDBY LOAD 0.85095 = AMPS NOTE 2. ALL WIRING TO BE 18AWG FPL. LL� Uo Standby Load Required Standby Time in Hours Z W Current (Amps) 0.12211 X 24 = 2.93 C Alarm Load Required Alarm Time in Hours SEQUENCE 0 I z w Current (Amps) (15 MINUTES) OPERATIONS: N J Z 0.85495 X 0.25 0.21 w z o L o N o Add Standby and Alarm Load for Required _j 0 oN - - Ampere Hour Battery 3.14 D W N af U) m Vi w Multiply by the Derating Factor of 1.2 Q O Total Ampere Hours Required = 3.77 a- w o VY CL _ = Jz � z °rrz rnw Batteries Provided: 7AH Minimum � O O w� Vn O Vn Vn O O H = I- F- != wH = z z z cn DEVICE a a D O N o I o a z z � zM z � > z DESCRIPTION > > o a a a W O tY O tY O U O 0 0 H H H H H H Q 2 SMOKE OR HEAT DETECTORS X X X SPRINKLER WATERFLOW SWITCH X X X X SPRINKLER TAMPER SWITCH X X W POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X U CARBON MONOXIDE DETECTOR X X X 0 ( � C:)V ) Q W z � � � O PROJECT INFORMATION : U REUSSWIG RESIDENCE L 3: __j VAIL, COLORADO U/ Q FIRE ALARM SYSTEM (J-) > AHJ: VAIL FIRE & EMERGENCY SERVICES APPLICABLE CODES: 2007 NFPA 72, 2009 IFC, 2009 IBC Lj_j OCCUPANCY: GROUP R USE: DUPLEX FIRE ALARM SYSTEM FOR WEST UNIT OF DUPLEX. SYSTEM WILL INCLUDE A NEW ADDRESSABLE VISTA 128 FACP. SMOKE DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS, STAIRWELL LANDINGS AND AREAS a OUTSIDE OF SLEEPING ROOMS. HEAT DETECTORS WILL BE INSTALLED IN THE KITCHEN, LAUNDRY AND GARAGE. SOUNDERS WILL BE PROVIDED IN SLEEPING ROOMS AND AS NEEDED TO ACHIEVE AUDIBILITY. A KNOX BOX WILL BE MOUNTED ON THE OUTSIDE OF THE HOME. w C/) D J cn Q Ln F_ z 1-:G Ld- FIRE PROTECTION ENGINEER: o `er' 0 q 35233 m 00 M'' , DEBORAH SHANER, P.E., SHANER LIFE SAFETY � °•., ::•r PO BOX 1073, FRISCO, CO 80443 PHONE: 970-409-9082 FAX: 970-797- 1898 FA-01 I F FIELD LOCATE SPRINKLER FIE] MONITOR POINTS, USE 017 FOR WATERFLOW AND 018 FOR TAMPER SWITCH. ooq Q"'51 o i a�zviF� w0 °m (nw00<0 wo U� J° w JO°�z w— mL� o m oa8z ma U) GARAGE ° w w o z w 109 °wWoc� zw aw GWB CLNG vwi�-�m-p� H� oz TO ABOVE @ 9,-0., a o w = a o w °a BEDROOM 1 I I Q�Q°zap �w Fn 104 ° >- J a.06 - - 001 ZQaZ°F o- in-U) GWBCLNG @8'-4" FACP ! Z°zvo�w Q� °zzo oawwwoz c< z Y TO FACP ooam�vi owv Nz H BAR W��w�ZO NQ� a o0 V)<p- ww gm 103 UP JwUwQ� w Nom° _j J W O-J O J �O O Q 1 <<-wmww 003 002 000 I I N ►� 0 rn MUD ROOM ., o 107 V ) O U o0) I z Q a Y TO FACP GWB CLNG O DECK @ 8'-5° Lo x I � � 102 005 004 o U m ENT��RY — — — LJ CAR PORT Uo � 111 z GWB CLNG W @ 8'-5" T& G CLNG @ 9'-0" I I Q® TO FACP 0 ol B LIBRARY 101 GWB CLNG LJJ @ 8'-4" U z W O I � C- Q II W z � � O W J u� Q LOWER LEVEL FLOOR PLAN U-) SCALE: 1/4" = 1' W Q m D U) w D J cn Q Ln F: z Rfjp r7 Ld s � V: 35233y © o0 ` ►CUP-� FA-02_ I-V) p w-- (f) O � ZO m O O p d ZV O - W- oO �00< ww U0 nw w N 0 O O J m w �JO°jrZ W mLL- m F W w 0U Z an d V)OO L,LLJ CE 0 Z w OwpOU Zm aw Z d w V)Z Vjf'02Z� f-W Z Q Ld W-j O(n aIL LLJOw = Qp - - jrW°wow °zw �Q WINE STORAGE KID'S BEDROOM aoZ}j Z oa 205 a.oww�Jm0 wQ NU) - - TO ABOVE GWB CLNG ap�oN� -J CL pm ? ° wmW3o to DINING ROOM 013 °praaao lla LLJ No 204 - - wjww�}O Q°� w¢ - - co�LV)< - cnWL oU JwC3wQOf w NFL p _j - - - - -1 F- - - - - - aw 0--J°w SSW a> H - - _ _ - _ _ L - - - - J L - - - - J 000 Nn I 012 011 - - - - - - - - - - - - - - - - - rn o \ GWB CLNG m L- __j rr nn O VAULTED V l Z n L — -A II GWB CLNG 1 OO rn a @ 8'-5" O GWB CLNG FROM BELOW @ 8'-2° GWB CLNG - 0 VAULTED - - - - - - - � HALL FROM BELOW T&�OLG 1 O ® 214 U m uq I I LH 0 2 o W z 007 008 KITCHEN MASTER b� 201 - - GWB CLNG EOLR RIDGE BEDROOM - - - @ 8'-2" 016 @ 10'-8" 1 ? 0 ? LIVING ROOM 1 009 p10 1 015 0141 206 F- - � GWB CLNG 9 [� GWB CLNG @ 8'-5" r GWB CLNG VAULTED I GWB CLNG L VAULTED LESS THAN 16' 1 @ $ 5 I - � II I I I I I - 1 T&G CLG IN COVE FAMILY ROOM TAIR 1 DN 20$ °®° DECK D® Q - - B.O. SOFFIT 1 W I 1 U L - - - - - - - - - � - - - - - - - - - - - - - - W ❑ ❑ I) 0 o v ) ~ W z � UPPER LEVEL FLOOR PLAN ° SCALE: 1/4" = 1' 0 cf) U W J MAIN LEVEL FLOOR PLAN Q SCALE: 1/4" = 1' (V�- ) W Q m U) w D J cn Q Ln P:: z R , r7 �r, LLJ o ttt Q M V 352331 - a0 FA-03_