HomeMy WebLinkAboutDRB130417 [���i��n R��ruew Br��rd
J4��I�N F�FiI�
�
- � Dep�i�tmen� c�f C�mmunity ��evelop�ri�rot
�'�`�� �� ' 75 Sauth Fa�€�n�ag� RoadF Vail f Cc�6crrad� 81f�.57
tel: 97!�.�+79.�13� fiax: �7t1.479.2�l5�
Li4+d.ihiUldlrY�'4�EL�7t"kii�3T "���Jo �!'�"4V9h�.�lf���'C�1Q�!if��C�fn�
Project Name: NEW CONSTRUCTION DRB Number: DRB130417
Project Description:
NEW MULTI-FAMILY PROJECT AT THE PARK MEADOWS LODGE SITE PROJECT INCLUDES 19
FREE MARKET DU'S AND 2 EHU'S WITH ASSOCIATED PARKING AND SITE IMPROVEMENTS
Participants:
OWNER BOYER, MICHAEL F. 09/09/2013
1472 MATTERHORN CIR
VAIL, CO
81657
APPLICANT BDP/SHOPWORKS 09/09/2013 Phone: 303-884-9131
WILL HENTSCHEL
2882 WYANDOT STREET
DENVER
CO 80211
Project Address: 1472 MATTERHORN CR VAIL Location: PARK MEADOWS LODGE
Legal Description: Lot: Block: Subdivision: VAIL PARK MEADOWS
Parcel Number: 2103-124-0101-4
Comments: Please see below.
BOARD/STAFF ACTION
Motion By: Kjesbo Action: APPROVED
Second By: Maio
Vote: 5-0-0 Date of Approval: 11/20/2013
Conditions:
Cond: 8
(PLAN): No changes to these plans may be made without the written consent of Town of
Vail staff and/or the appropriate review committee(s).
Cond: 0
(PLAN): DRB approval does not constitute a permit for building. Please consult with
Town of Vail Building personnel prior to construction activities.
Cond: 201
(PLAN): DRB approval shall not become valid for 20 days following the date of
approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS.
Cond: 202
(PLAN): Approval of this project shall lapse and become void one (1) year following
the date of final approval, unless a building permit is issued and construction is
commenced and is diligently pursued toward completion.
Cond: CON0013493
1. Prior to the issuance of a building permit, the applicant shall enter into a cost
sharing agreement approved by the Town of Vail Public Works and Community
Development Departments for the landscaped separation between the project's driveway
and the Town bike path.
2. Prior to the issuance of a building permit, the applicant will revise the snow
storage plan to be reviewed and approved by the Town of Vail Public Works and
Community Development Departments.
3. Prior to the issuance of a building permit, the plans shall be revised to include
the required guardrail on the west edge of the loading bay and to delete the storm
sewer tie into the north culvert.
4. Prior to the issuance of any Building Permit or Certificate of Occupancy, as
applicable, the applicant shall satisfy all requirements of Chapter 24, Inclusionary
Zoning, Vail Town Code concerning the Employee Housing obligation. Based on a net
increase in GRFA of 22,960 square feet, 2,296 square feet of inclusionary zoning
mitigation is required. At least 1,148 square feet shall be provided on-site. Any
fee-in lieu or off-site arrangements must be satisfied prior to building permit
issuance.
Planner: Jonathan Spence DRB Fee Paid: $650.00
****+*+***++******************+**********+++********+***************************************
TOWN OF VAIL, COLORADOCopy Reprinted on 09-10-2013 at 15:04:28 09/]0/2013
Statement
**************************************************�************************��***************
Statement Number: R130001407 Amount: $650.00 09/10/201303:04 PM
Payment Method:Credit Crd Init: CG
Notation: visa franklin a
boyer
-----------------------------------------------------------------------------
Permit No: DRB130417 Type: DRB - New Construction
Parcel No: 2103-124-0101-4
Site Address: 1472 MATTERHORN CR VAIL
Location: PARK MEADOWS LODGE
Total Fees: $650.00
This Payment: $650.00 Total ALL Pmts: $650.00
Balance: $0.00
********************************************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
DR 00100003112200 DESIGN REVIEW FEES 650.00
-----------------------------------------------------------------------------
�t����rr �� �rara �
Jt�l(�T PRC►t��R'T'Y �'JVV'M�""Ni�R
w�rrr�r� aR��t�ue�� � �--r-r�R
�s�� d���u:�e�c m��x su�tt� �vrsrten ��rtt Pra�rtY cnvrset �pprova� npr �pPu�a�4n�. 3rr�rtg �rssre� txwrterso7� ptop�ettt�s
su�h �5 c�p�ex, rcand�ominium, �nd mutti tee�a�t buildin�s 7'ha� fctrrn, +�r simil�r u�r� c�spond�nC�. me�t b�
corr�pi�ad try 1�� a�ininc�duplex c�nit ta+vnGr or tt� authdiz�d �g�nt c�F tA� home t»vne�`s assOCi�tion �n the c�e t�t a
cor�dt�minium pr mu�-ter�nt b�rildin�. All ccamplet�cl tnrms must be s��bmitt�d+wiit�#he�ppdica�Cv�'►p��d�ppfiqtivn.
���
�. (PnM nart�e�j '��� ���"' , a�nt ovr��r, or�thorrty af#h� a�a�ti�an, of
pr�Br�Y 10� 8tt �4T����tb�rt�btrt�ir
, �an�+t� this I�r as wri�n
ap{�ro�+�i tu m�t p�s o�� writcst r�;tvc� c�.�t ��rxriu�aa ata tt� r awn
of V'ail Community[�rt.r�eFoprr�t D�rtment far it��prc,p�os�:ci unprov�rr�rrts to De c,�rr�d�t�e�ire�s nc#ed abc�ve
►�w m�G-t�en�ty prc�j�ct
t u��b.e�wt uie► itGVU�iw.e�++�n�aa +ire�r u� ���+�.a ti�r u�� M����r xrva� c�►� wu«,e +W� u�a �ew.,�w ��vw000 w �i«��r�a e.vi�.w,ia�wc
witt� tht� Tt�m's �plic�bl� c�odes and regu�ati�ans, �nd th;a#it �s tt►�e s�Q1e responsibilat�r of f�te 2�tit�t�t to ke�ep tt�jafnt
pc'�rh'owru�r r�rri�cd at�ny oh�g�s �d er►suu��a �tst tt�e ct��r�a are acc�ept�ble ar�d ��i�t. S�l7m+itGE►t 4f�n
�, _ _ —�
r .
�� . � ��
. �
� �
��,� ���
�
�
�
Department of Community Development
75 South Frontage Road
TOWN OF 11Arf. vai�, CO 81657
Tel: 970-479-2128
www.vailgov.com
Development Review Coordinator
Application for Design Review
New Construction
General Information: This application is for all new construction. Applicable Vail Town Code sections can be
found at www.vailgov.com under Vail Information — Town Code Online. All projects requiring design review
must receive approval prior to submitting a building permit application. An application for Design Review
cannot be accepted until all required information is received by the Community Development Department, as
outlined in the submittal requirements. The project may also need to be reviewed by the Town Council and/or
the Planning and Environmental Commission. Design review approval expires one year from the date of
approval, unless a building permit is issued and construction commences.
Fee: $650
� Single Family � Duplex U'� Multi-Family � Commercial
Description of the Request: New mutiple family project at the Park Meadows Lodge property
Physical Address: 1472 Matterhorn Circle
Parcel Number: 2103-124-01-014 (Contact Eagle Co. Assessor at 970-328-8640 for parcel no.)
Property Owner: Michael F Boyer
Mailing Address: 1472 Matterhorn Circle
Vail, CO 81657 Phone: 303-884-9131
Owner's Signature:
Primary Contact/ Owner Representative: Will Hentschel, BDP/Shopworks
Mailing Address: 2882 Wvandot Street
Denver, CO 80211 Phone: 303-884-9131
E-Mail: willhentschel(a�gmail.com Fax:
For Office Use Only:
Cash CC: Visa/ MC Last 4 CC# Exp. Date: Auth# Check#
Fee Paid: Received From:
Meeting Date: DRB No.:
Planner: Project No.:
Zoning: Land Use:
Location of the Proposal: Lot: Block: Subdivision:
r�wr� �� var�
JOINT PROPERTY OWNER
WRITTEN APPROVAL LETTER
The applicant must submit written joint property owner approval for applications affecting shared ownership properties
such as duplex, condominium, and multi-tenant buildings. This form, or similar written correspondence, must be
completed by the adjoining duplex unit owner or the authorized agent of the home owner's association in the case of a
condominium or multi-tenant building. All completed forms must be submitted with the applicants completed application.
I, (print name) Franklin Boyer/ Park Meadows , a joint owner, or authority of the association, of
property located at 1472 Matterhorn Cir , provide this letter as written
approval of the plans dated 8-26-13 which have been submitted to the Town
of Vail Community Development Department for the proposed improvements to be completed at the address noted above.
I understand that the proposed improvements include:
new multi-family project
I understand that modifications may be made to the plans over the course of the review process to ensure compliance
with the Town's applicable codes and regulations; and that it is the sole responsibility of the applicant to keep the joint
property owner apprised of any changes and ensure that the changes are acceptable and appropriate. Submittal of an
application results in the applicant agreeing to this statement.
091013
Signature Date
Franklin Boyer
Print Name
Property Information
Property Address 1472 Matterhorn Circle
Parcel# 2103-124-01-014
Legal Description Park Meadows Lodge (unplatted)
Development Site Area sq ft acres buildable sq ft
43,375 .995 acres 43,375
Zone District/SDD# HDMF
Hazard Zones Snow Avalanche �High Severity r"Moderate Severity �;N/A
Sections 12-21 & 14-7 Debris Flow " High Flow ' Moderate Flow I High Avalanche �� N/A
Rock fall High Severity ! Medium Severity �� N/A
Excessive Slopes � >_30% (� N/A
Floodplain 100 year floodplain �J Floodway �Wetlands �� V/A
Creeks, Streams Gore Creek �on site I� adjacent to site � N/A
Section 12-14-17 ❑Other tributary: I on site �adjacent to site ' N/A
Project Information
Project Description New multi-family project
Development Standards Allowed Existing Proposed
Gross Residential Floor Area Primary sq ft 32965 9000 32476
(maximum)
Chapter 12-15 Secondary sq ft
EHU sq ft 2400 1000 2400
TOTAL sq ft 35365 10000 34876
250 Addition Interior Conversion
Credits:
Setbacks (minimum) Front ft 21' 21' 21'
Section 14-10-4
Side ft 20.5' 20.5' 20.5'
Side ft 21� 21' 21'
Rear ft 20' 20' 20'
Watercourse ft
Site Coverage (maximum)
see definition Section 12-2-2 see mpg see mpg 23650
Building Height(maximum) Sloping ft
see definition Section 12-2-2 Flat ft 46,42 46,42 46,42
Landscaping Softscape sq ft 21096 21096 21096
See definition Section 14-2-1
Section 14-10-8 Hardscape sq ft 4555 4555 4555
TOTAL sq ft 23561 23561 23561
Driveway Max Curb-cuts � 1 1
Sections 14-3-1 & 14-3-2
Max Grade @
centerline
Min Width 22 22 22
Heated drive? �Yes "� No �Yes �— No
Snow Storage % 20o�o
Parking #Enclosed Spaces
Sections 12-10& 14-5 #Unenclosed 48 34 41, 2
TOTAL
Outdoor Lighting (maximum) #fixtures
Section 14-10-7 30
��yy� �� y��� _`' DESIGN REVIEW PROCESS
Pre-application Meetinq
A pre-application meeting with Town of Vail Staff is not required; however, highly recommended. The purpose of a pre-
application meeting is to identify any critical issues pertaining to the proposal and to determine the appropriate
development review process for an application. Please call the Development Review Coordinator at 970-479-2128 to
schedule a meeting.
Deadlines and Meetinq Dates
The Design Review Board meets on the 1 st and 3rd Wednesdays of each month beginning at 3:00 pm. Complete
applications are due in the Office of Community Development no later than 12:00 noon on the submittal deadlines below:
Submittal Deadlane Meet�ng Date
December 10, 2012 January 2, 2�13 Cor�#inued... Conxinuea�...
December 24, 2�12 January 15, 2013 Submittal �eadli�e Meeting Date
January 14, 2Q13 Felaruary 6, 2�13 July'15, 2013 August 7, 2013
January 28, 2D13 February 20, 2a13 July 29, 2013 August 2�, 2D13
Februar 11, 2�13 March 6, 2D13 Au �st 12, 2�13 Se tember 4, 2D13
Februa 25, 2013 March 20, 2�'13 Au ust 26, 2013 Se tember 18, 2�13
VVlarch 1 fi, 2012 A rll 3, 2�13 Se tember 9, 2013 C7ctober 2, 2Q13
�larch 25, 2013 A ril 1 F, 2013 Se tember 23, 2Q13 October 16, 2a13
A ril 8, 2013 Ma 1, 2013 C7ctober 14, 2013 �'ovem�r 6, 2CJ13
A rfl 22; 2013 Ma 15, 2013 October 28„ 2Q13 Na�vember 2�, 2D13
91Aa 13, 2013 June 5; 2013 '�lovember 11, 2013 December 4, �D13
Ma 28, 2�13 .�une 19, 2013 �Javember 25 2013 December 18 2�93
June 10, 2013 �Dul 3, 2D13 De�ember 9, 2�D13 Januar 1, 2Q14
June 24, 2013 .�ul 17, 20'13 I]ecember 23, 2013 Janua 15, 2�14
Application Submittal
Submit all required information under the submittal requirements section of this application by the deadlines stated above.
Incomplete applications will not be processed. Upon receipt of a complete application, the Community Development
Department shall review the submitted materials for general compliance with the appropriate requirements of the zoning
code. If the application is not in compliance with zoning code requirements, the application and submittal materials shall
be returned to the applicant with a written explanation of non-compliance.
Staff Review
The Administrator(a member of the Planning Staff)will review and either approve a Design Review application, approve it
with conditions, deny the application, or refer the application to the Design Review Board for a decision. All Staff
approvals are reviewed by the Design Review Board and any administrative decision is subject to final approval by the
Board. The Board reviews applications and may approve, approve with conditions, deny the application, or table the
application to allow applicants to respond to comments.
Desiqn Review Board Meetinq Requirements
Prior to the meeting, for new construction and additions, the applicant must stake and tape the project site to indicate
property lines, proposed buildings and building corners. All trees proposed to be removed must be marked. The
applicant must ensure that staking done during the winter is not buried by snow.
The applicant, or their representative(s), shall be present at the Design Review Board public meeting. The item will be
postponed if the applicant fails to appear before the Design Review Board, on their scheduled meeting date.
SUBMITTAL REQUIREMENTS
The Town of Vail offers two (2) methods for submittal of materials for review of applications. Materials can be submitted
either digitally or on paper. Whichever method you select all materials shall be submitted in that format throughout the
Design Review process. The Town encourages you to consider using the submittal of digital documents and plans.
If submitting digitally all elements of the application shall be uploaded to the Town's share file site as a complete set of
materials. If submitting paper three (3) copies of the materials noted with an asterisk (*) and one (1) copy of all others are
required. The materials necessary to have a complete application are as follows:
- Completed application form including owner's signature (cover sheet).
-i Application fee
o Additional fees may be required if: 1)Any local, state or Federal agency review is required, 2) Publishing fees
are in excess of 50% of the application fee, or 3) External consultants are required by the Town to review
significant impacts on the community.
- Project narrative describing the background, purpose and details of the proposal (Address To: Design Review Board).
- Digital presentations to the board are required to be provided no later than the Wednesday prior to the meeting date.
These materials are considered part of the public record. Example is powerpoint presentations.
- Title report, including Schedules A& B to verify ownership and easements.
- Joint Property Owner Written Approval Letter, if applicable (pg. 2). This form is applicable to all Design Review
applicants that share ownership of the subject property. For example, the subject property where construction is
occurring is a duplex, condominium or multi-tenant building. This form shall be completed by the applicanYs neighbor/
joint property owner. In the case of a multiple-family dwelling or multi-tenant building, the authority of the association
shall complete this form.
- Utility Approval and Verification Form, if applicable (pg. 7). This form is applicable to any construction within an
easement and may be required for any construction if deemed necessary by Town of Vail Staff.
- Plan Sheet Format(Applies to all plan sheets)
• Plan sheet size must be 24"x 36". For large projects, larger plan size may be allowed.
• Gra hic bar scale minimum scale is 1"=20' .
p � )
• North arrow.
• Title block, project name, project address and legal description.
• Indication of plan preparer, address and phone number.
• Dates of original plan preparation and all revision dates.
• Sheet labels and numbers.
• A border with a minimum left side margin of 1.5".
• Plan legend.
- Plan Set Cover Sheet*
• Project name.
• Address and legal description.
• Sheet Index.
• Preparer's contact information and other relevant contacts (i.e. Owner, Surveyor, Contractor).
• Vicinity map or location map at a scale of 1"=1,000' or larger.
- Stamped Topographic Survey*
• Wet stamp and signature of a licensed surveyor.
• Scale of 1"=10' or 1"=20'.
• Legal description and physical address.
• Lot size and build able area (excludes red hazard avalanche, slopes greater than 40%, and floodplain).
• Labeled ties to existing benchmark, either USGS landmark or sewer invert.
• Property boundaries to the nearest hundredth (.01)of a foot accuracy. Distances and bearings and a basis of
bearing must be shown. Show existing pins or monuments found and their relationship to the established corner.
• Show right of way and property lines; including bearings, distances and curve information.
• Indicate all easements identified on the subdivision plat and recorded against the property as indicated in the title
report. List any easement restrictions.
• Spot Elevations at the edge of asphalt, along the street frontage of the property at twenty-five foot intervals (25'),
and a minimum of one spot elevations on either side of the lot.
• Topographic conditions at two foot contour intervals.
• Existing trees or groups of trees having trunks with diameters of 4" or more.
• Rock outcroppings and other significant natural features (large boulders, intermittent streams, etc.).
• All existing improvements (including foundation walls, roof overhangs, building overhangs, etc.).
• Environmental Hazards (i.e. rock fall, debris flow, avalanche, wetlands, floodplain, soils).
• Wetland delineation and provide any necessary approvals or permits from Colorado Department of Natural
Resources and/or Army Corp of Engineers.
• Watercourse setbacks, if applicable (show centerline and edge of stream or creek in addition to the required
stream or creak setback).
• Show all utility meter locations, including any pedestals on site or in the right-of-way adjacent to the site. Exact
location of existing utility sources and proposed service lines from their source to the structure. Utilities to include,
cable TV, sewer, gas, telephone, water, electric, size and type of drainage culverts, swales, etc.
• Adjacent roadways labeled and edge of asphalt for both sides of the roadway shown for a minimum of 250' in
either direction from property.
• Any adjacent sidewalks and trails.
-i Site and Grading Plan*
• Scale of 1"=20' or 1"=10' (The site and grading plan must be drawn at the same scale as the topographic survey).
• Lot size and buildable area (excludes red hazard avalanche, slopes greater than 40%, and floodplain).
• Property and setback lines.
• Existing and proposed easements.
• Existing and proposed grades. All disturbed areas must be returned to a 2:1 grade or PE stamped details of
slope protection and/or stable soils are required.
• Existing and proposed layout of buildings and other structures including decks, patios, fences and walls. Indicate
the foundation with a dashed line and the roof edge with a solid line.
• All proposed roof ridge lines with proposed ridge elevations. Indicate existing (natural grade prior to construction
of structure) and proposed grades shown underneath all roof lines. This will be used to calculate building height.
• Proposed driveways: Site plan must show driveway type, finished surface, heated or unheated, grade, percent
slope, dimensions, turning radii, site distance, required parking spaces with 9' x 19' surface parking spaces and 9'
x 18' enclosed spaces, and spot elevations at the property line, garage slab and as necessary along the
centerline of the driveway to accurately reflect grade.
• A 4'wide unheated concrete pan at the edge of driveway.
• Locations of all utilities including meter pits, existing sources and proposed service lines from sources to the
structures.
• Proposed surface drainage on and off-site, including culverts.
• Location of landscaped areas.
• Location of limits of disturbance fencing.
• Names of all adjacent roadways.
• Snow storage must be shown within property boundaries adjacent to driveway (30% of driveway area if unheated,
10% of driveway area if heated).
• Proposed dumpster location and detail of dumpster enclosure.
• Retaining walls with proposed elevations at top and bottom of walls. A detailed cross-section and elevation
drawings shall be provided on the plan or separate sheet. Stamped engineering drawings are required for walls
between 4' and 6' feet in height and all combination walls.
• If less than one half acre is to be disturbed, proper erosion control devices need to be shown on the site plan. If
more than one half acre is to be disturbed, then a separate professionally engineered and PE stamped Erosion
Control Plan must be submitted.
• 100-year floodplain.
• Location of all geologic/environmental hazard areas.
• Delineate areas to be phased and appropriate timing, if applicable.
- Landscape Plan*
• Scale of 1" = 20'or 1" = 10'
• Landscape plan must be drawn at the same scale as the site plan.
• Location of existing trees, 4" diameter or larger. Indicate trees to remain, to be relocated (including new location),
and to be removed. Large stands of trees may be shown (as bubble) if the stand is not being affected by the
proposed improvements and grading.
• Indicate all existing ground cover and shrubs.
• Detailed legend, listing the type and size (caliper for deciduous trees, height for conifers, gallon size for shrubs
and height for foundation shrubs) of all the existing and proposed plant material including ground cover.
• Delineate critical root zones for existing trees in close proximity to site grading and construction.
• Indicate the location of all proposed plantings.
• The location and type of existing and proposed watering systems.
• Existing and proposed contour lines. Retaining walls shall be included with the top of wall and the bottom of wall
elevations noted.
• Landscaping summary, including the botanical and common names, size and quantity of trees to be removed and
proposed trees. The minimum size for proposed trees is 2" caliper deciduous trees, coniferous trees that are six
feet in height, and 5 gallon shrubs. Also specify types of groundcover and proposed square footage. Include a
description of any other landscaping features (ponds, fountains, retaining walls, pools, etc).
Architectural Elevations*
• Scale of 1/8" = 1' or larger; 1/4" = 1' is preferred.
• All elevations, existing and proposed, of the proposed development shall be drawn to scale and fully
dimensioned. The elevation drawings must show both existing and finished grades. Floor plans and building
elevations must be drawn at the same scale.
• Show all building faces including angles not represented well on the normal building elevations.
• Elevations shall show proposed finished elevation of floors and roofs on all levels.
• All exterior materials and colors shall be specified on the elevations.
• The following shall be shown graphically and fully dimensioned: fascia, trim, railings, chimney caps, meter
locations, meter screening methods and window details.
• Show all proposed exterior lighting fixtures on the building.
• Illustrate all decks, porches and balconies.
• Indicate the roof and building drainage system (i.e. gutters and downspouts).
• Indicate all rooftop mechanical systems and all other roof structures, if applicable.
• Illustrate proposed building height elevation on roof lines and ridges. These elevations should coordinate with the
finished floor elevations and the datum used for the survey.
• Exterior color and material samples shall be submitted to staff and presented at the Design Review Board
meeting.
_i Architectural Floor Plans*
• Scale of 1/8" = 1' or larger; 1/4" = 1' is preferred.
• All floor plans, existing and proposed, of the proposed development shall be drawn to scale and fully
dimensioned.
• Floor plans and building elevations must be drawn at the same scale.
• Clearly indicate the inside face and outside face, of the sheathing, of the exterior structural walls of the building.
• Label floor plans to indicate the proposed floor area use (i.e. bedroom, kitchen, etc.).
• One set of floor plans must be "red-lined" indicating how the gross residential floor area (GRFA)was calculated.
See Title 12, Chapter 15—Gross Residential Floor Area for regulations.
• Provide dimensions of all roof eaves and overhangs.
- Lighting Plan"
• Indicate type, location and number of fixtures.
• Include height above grade,
• Cut sheet(s)for proposed fixtures demonstrating compliance with 14-10-7, Outdoor Lighting, Vail Town Code.
-� Gross Residential Floor Area calculations (including allowable, existing, proposed, and total GRFA for all units in the
development plan, including the other half of a duplex).
- Site Development Standards calculations (existing and proposed): landscape area (show softscape & hardscape),
site coverage, building height, number of dwelling units and employee housing units, setbacks, number of enclosed
and unenclosed arkin s aces, drivewa area, snow stora e area etc.
P 9 P Y 9
- One set of consolidated overlapped floor plans must visually demonstrate how site coverage was calculated. See
Section 12-2-2, Definitions, Vail Town Code, for those elements which are considered site coverage.
- Exterior building materials list (also to be included on elevations and in materials samples), including location, type of
material, and color. Please specify the manufacturer's name, the color name and number.
- Exterior color and material sam les and s ecifications. A h sical material sam les and s ecifications board will
P p P Y P p
need to be provided in conjunction with a digital submittal.
- Photos of the existing site and adjacent structures, where applicable.
= Site-specific Geological Hazard Report, if applicable - If a property is located in or adjacent to a mapped hazard area
(i.e. snow avalanche, rockfall, debris flow, floodplain, wetland, poor soils, etc.), the Community Development
De artment ma re uire a site-s ecific eolo ical investi ation.
P Y q p 9 9 9
-i The Administrator and/or DRB may require the submission of additional plans, drawings, specifications, samples and
other materials (including a model) if deemed necessary to determine whether a project will comply with Design
Guidelines or if the intent of the proposal is not clearly indicated.
PROPOSED MATERIALS
Buildinq Materials Tvpe of Material Color
Roof M eta I G u n m eta I G rey
Siding WOOC) Browns
Other Wal� Materials Concrete, Metal Grey. Corten
Fascia Wood Match Roof
soff�tS wood match siding slightly
Windows Metal Gunmetal Grey
Window Trim Wood or no trim match siding
Doors Wood Dark Brown, Light Brown
Door Trim None NA
Hand or Deck Rails Wood /Metal Dark Wood, Gunmetal
Flues Metal Gumetal
Flashing Match Roof Match roof
Chimneys Cement Board Paitn to match roof
Trash Enclosures in Garage na
Greenhouses na na
Retaining Walls concrete/corten grey, rusted metal
Exterior Lighting see landscape see landscape
Other
PROPOSED LANDSCAPING
Botanical Name Common Name Quantitv Size
PROPOSED
TREES see landscape
AND SHRUBS
EXISTING TREES
TO BE REMOVED
Minimum Requirements for Landscaping: Deciduous Trees—2" Caliper
Coniferous Trees—6' in height
Shrubs—5 Gal.
Tvpe Square Footaqe
GROUND COVER
SOD
SEED
IRRIGATION
TYPE OF EROSION CONTROL
Please specify other landscape features (i.e. retaining walls, fences, swimming pools, etc.)
UTILITY APPROVAL &VERIFICATION
This form serves to verify that the proposed improvements will not impact any existing or proposed utility services, and
also to verify service availability and location for new construction and should be used in conjunction with preparing your
utility plan and scheduling installations. A site plan, including grading plan, floor plan, and elevations, shall be submitted
to the following utilities for approval and verification. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COM-
MENTS FROM THE UTILITY COMPANIES. If you are unable to obtain comments within that timeframe please contact
The Town of Vail.
Subject Property Address: 1472 Matterhorn Circle Lot Block Subdivision:
Primary Contact/Owner Representative: Will Hentschel Phone: 303-884-9131
Plans Dated: 090913
Primary Contact/Owner Representative Signature
Authorized Siqnature Comments Date
CENTURY LINK
970.328.8288(tel)
970.328.8282 (fax)
Contacts: Barb Davis
barb.davis(a�centurylink.com
XCEL HIGH PRESSURE GAS
970.406.1784(tel)
970.468.1401 (fax)
Contact: Remington Baker
reminqton.c.baker(a�xcelenerqv.com
HOLY CROSS ENERGY
970.947.5425(tel)
970.945.4081 (fax)
Contact: Jeff Vroom
jvroom(cD.holvcross.com
XCEL Energy
970.262.4039(tel)
970.262.4038(fax)
Contacts: Pam McGuire
pamela.mcquire(cr�.xcelenerqy.com
EAGLE RIVER WATER&SANITATION
DISTRICT
970.477.5449(tel)
970.845.7218 (fax)
Contact: Tug Birk
tbirk(a�erwsd.orq
COMCAST CABLE
970.930.4713(tel)
303.603.1004 (fax)
Contact: Michael Johnson
Michael iohnson(a)cable.comcast.com
CDOT(Only in CDOT Right-of-way)
970.683.6284(tel)
Contact: Dan Roussin
Daniel.roussin a(�.dot.state.co.us
NOTES:
1. Utility locations must be obtained before digging.
2. A Revocable Right-of-Way Permit may be required for any improvements within a street right-of-way. Contact the
Public Works Department for verification 970.479.2198.
3. It is the responsibility of the utility company and the applicant to resolve problems identified above.
4. The Primary Contact/Owner Representative is required to submit any revised drawings to the above agencies for
re-approval & re-verification if the submitted plans are altered in any way after the authorized signature date.