Loading...
HomeMy WebLinkAboutVent Cap Option 2These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together. Refer to the Installation and Operating Instructions for proper gas supply, safety requirements and operating instructions. C i �• 1 e TOWN & COUNT RY FIREPLACES'M STAIN LESS STEEL VENT TERMINAL rf' p a IM p TCVT.SSWTA INSTALLATION AND OPERATING INSTRUCTIONS 281105 -4 TCVT.SSWTA 5056.4267 The TC Stainless Steel Vent Terminal is intended for use in climates that warrant stainless steel construction as well as in hard to reach places. The 2 phase installation allows the sleeve to be installed during the construction phase, while the terminal can be installed at the same time as the fireplace. This terminal kit can be used both in residential and commercial installation. EXTERIOR WALL OPENING Having determined the position of the fireplace, cut and frame a 16 3/4 x 16 3/4 inch opening centered at a minimum height above the floor as specified in the fireplace manual. Height of the opening will vary with each installation. As the horizontal vent run increases, so does the minimum vertical rise. IMPORTANT: When locating the opening, it should be noted that vent terminal exterior clear- ances must be maintained. See "Vent Terminal Clearances" section in the fireplace manual for proper clearances. SLEEVE INSTALLATION Slide the mounting flange over the sleeve so that the fastening holes are oriented to the side of the sleeve. Set the flange back far enough so that the sleeve will protrude a minimum of 1" beyond the exterior wall surface. Flange set back will depend on the type of installation. If the sleeve is to be fas- tened over top of siding, set the flange back 1" from the end of the sleeve. If the sleeve is to be fastened under the siding or wall veneer assembly, set the flange 281105 -4 TYRGAL FRWI FCRTBIVIIMAL i ya * o-�tio i R w 1 jj L As per installation manual• — y'k ,5 f oh f 4� ORAIN'AaE " "� DfUU AGE , HOLE `- HOLE J TCVT.SSWTA 5056.4267 (Sleeve installation Continued) back the thickness of the veneer plus 1 ". To ensure that the terminal mounts on a 2° descending angle, set the flange back 1/2" more on the top than at the bottom. Bottom of the sleeve is identified by a small drainage hole located near the front. Drill 1/8" holes and fasten flange to sleeve with screws provided. Install the sleeve assembly through the wall opening from the outside of the build- ing. Fasten the sleeve assembly to the building ensuring that the assembly is on a downward slope to the outside and the small drainage hole is at the bottom. The 2° descending angle is necessary to ensure that there is no water accumulation within any of the terminal components. VENT TERMINAL INSTALLATION Apply a bead of silicone on the front face of the terminal. With embossed arrow pointing up, insert the termination into the sleeve, guiding the holes over the studs. Fasten termination in place using the washers, lockwashers and nuts provided. Install insulation material into sleeve, followed by insulation retainer. Insulation retainer should be fastened to terminal sleeve using 4 screws. Install remainder of venting as per the installation instruction supplied with the fireplace. TYPICAL OCMM&CIAL INSTALLATCN INTERIOR WALL MEMBRANE WALL SS SLEEVE FLANGE---,,,,,,, j NEUTRAL CURE / SILICONE -- HIGH TEMPERATURE INSULATION (SUPPLIED) VVVV' ji WATER DAM 2.00° PROVIDED BY BEAD ROLL HIGH TEMPERATURE STAINLESS STEEL SILICONE WALL TERMINAL / - TRIM SLEEVE TO FIT WALL 114" STAINLESS STEEL WELD STUDS TYPICAL WALL VENEER ASSEMBLY / 4 \_APPLYSILICONE v / TO FRONT FACE OF TERMINAL / BEFORE INSTALLATION a 281105 -4 TCVT.SSWTA 5056.4267 RB'LACEMBVf PARTS V TOWN & COUNTRY FIREPLACES TM :%l z .aa%1zQBI www .townandcountryfireplaces.net Toll Free: 1- 888 - 223 -0088 2975 Allenby Road, Duncan, BC Canada V91L 6V8 Printed in Canada 5056.4267