Loading...
HomeMy WebLinkAboutA13-0060 cut sheets Security Standard features Overview Expandable to 192 fully programmable hardwire The NetworX NX-8E is a full-featured security system and/or wireless zones that uses advanced technology for burglary, fire and • 240 user codes environmental detection. The NX-8E is a flexible security system that is both easy to install and simple to use. R Up to 192 addressable devices can be used With eight partitions and up to 192 zones, the NX-8E can � 512-event history log that provides date, time, event handle your most demanding commercial and and user number residential security needs. Up to 8 true partitions with separate account codes, Outstanding features entry/exit delays, and feature selections for each partition The NX-8E panel comes standard with eight hardwire � Maximum of 32 keypads with up to 8 per partition zone inputs and two relays. Four programmable outputs can be set up to activate external devices during an Wireless technology with up to 192 supervised zones alarm or other system event. The modular design allows � 2-wire or 4-wire smoke detector compability for complete integration of multiple systems within one • Fire alarm verification for greater false alarm immunity enclosure. Adding more zones or expanding capability is fast and easy. < Dynamic battery test _ • Standard RS-232 on-board interface Convenient and flexible Conduct quick and easy on-site programming with alphanumeric keypads and a menu-driven text interface. Off-site programming is also available with the DL-900 software for Windows. NetworX Control Panel N X-8 E - ��� �`�- -_ �. ��� 5,.. � � �l� ��]YI�_• '��+�IJF�� � � �cr qe � °rr � � � !�f� � � � � � Security NetworX Control Panel NX-8E Available Keypad Styles Specifications • Operating Power - 16.SV AC 40VA � � Auxiliary w/40VA or 50VA transformer - 2 Amp • Auxiliary w/NX-320E power supply - 3 Amps* N I ' Loop resistance �' For standard loop - 30052 Maximum For 2-wire smokes - 3052 Maximum LED with LCD with Operating temperature Removable Door Removable Door 32° to 120°F Dimensions � 6.40 inches wide �i�! � � 4.0 inches high �� � �— 0 1.10 inches deep � I Shipping weight � �' 9 pounds Fixed Display with LED with *When using the NX-320E Iw/SOVA transformer)rated at 2 Amps and NX-SE Removable Door Removable Door Iw/40VA or SOVA transformerl rated at 1 Amp,the combined available power is 3 Amps. Customer Service and Technical Support: 1-888-GE Security (437-3287) 12345 SW Leveton Drive Tualatin,OR 97062 Phone:503-692-4052 USA&Canada:800-547-2556 www.gesecurity.com / i � imagination at work OO 2005 GE Security. NetworX is a trademark of GE Security All other trademarks are properties of their owners. 466-2134-KA-0105 NetworX NX-148E-RF touchpad Secu rity The NX-148E-RF is an integrated 48-zone wireless receiver LCD keypad with traditional design and an easy-to-read, customizable display. It is compatible with all NetworX control panels (except commercial fire). The NX-148E-RF offers the are also five pre-programmed touch Features convenience of having an integrated keys that allow the most common wireless receiver built into the keypad functions to be performed with ease. • Integrated 48-zone wireless along with standard hardwire features. All keys on the NX-148E-RF are backlit receiver A removable door allows the user to ensure error-free operation—even . Optimize wireless reception by to swing the door down or simply in a dark room. having the keypad/receiver in the take it off for use.The NX-148E-RF The NX-148E-RF is cost-effective best location emergency keys are highlighted on and easy to install. Designed for • LCD, easy-to-read programmable the keypad and can be programmed functionality and compatibility,the NX- display to contact and send complete 148E-RF is the right keypad to fit any information to a responding police,fire application. • Traditional design to go with any or EMS unit with just one touch.There decor • Compatible with all NetworX series control panels (except commercial fire) N etwo rX N X- 148 E— I \ � ' Easy to install, program and maintain wireless �CD display keypad � _ _ �,. . . .. . ._�.. , �� . ��I 11 ��r��� ���:�ar�j �� Armed Reatly Fire Power � � � o 6"�-r - - ��"�" - �.;'„:: ,:_ �r_� - ��;�� �. � � � � , / / ' S ecifications p Americas Electrical Ordering information 503-885-5700 •Current:75 to 110 mA nominal NX-148E-RF NetworX 48-zone LCD display 888-GE-SECURITY Environmental keypad with door and integrated (437-3287) .Operating temperature:32 to 120°F(0 to 49°C) wireless receiver faxback 800-483-2495 PhySlCql info@gesecurity.com . Dimensions(HxWxDI:5.30 x 6.20 x 1.30 in.(135 x www.gesecurity.com 157 x 33 mm) •Construction:ABS plastic Asia •Color:White te1852-2907-8108 fax 852-2142-5063 Australia tel 61-3-9259-4700 fax 61-3-9259-4799 Europe tel 32-2-725-11-20 fax 32-2-721-86-13 Latin America te1305-593-4301 fax305-593-4300 O 2006 GE Security. As a company of innovation,GE Security reserves the right to change product specifications without notice.For the latest product specifications,visit GE Security online at www.GESecurity.com or contact your GE Security sales representative. 20060322 DS nx-148e-rf 466-70.B �� SYSTEM _ . ,y _ ,_ , _ ��� SENSOR° � ��;:��� � . � * C01224T Carbon Monoxide � �� Detector ,� with RealTestTmTechnology � ,�,;�� i � .�� � � The System Sensor C01224T CO detector provides early - � _� �,,�: �� warning by using electrochemical sensing technology ° -� to measure carbon monoxide levels in the air. Features With RealTest`"technology,the CO gas sensing cell of the •RealTest�"technology allows installer to test detector with CO gas C01224T CO detector can be tested using a carbon monoxide gas agent Simply hold the test button for two seconds.After the alarm •Full compliance with UL 2075 cyde(temp 4)the green LED will flash about once per second, •A code required trouble relay indicating that the detector is ready to accept CO for testing. •Wiring supervision with SEMS terminals Spray a small amount of CO into the detector per the installation instructions,and within seconds the detector will alarm,indicating •A six year end-of-life timer successful gas entry. •12/24 VDC •A current draw of 20mA in standby and 40mA in alarm If dangerous amounts of carbon monoxide is detected,the C01224T detector will alert residents by sounding and flashing a temp-4 signal •Versatile mounting for wall and ceiling alarm.Protection is guaranteed 24/7 by a central station,regardless •Electrochemical sensing technology of whether residents are away from home,sleeping or already suffering from the efFects of C0. This specific device is designed for system operation.The detector is fully listed to UL 2075.It offers a code required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station.It also uses SEMS-type terminal Philips head screws to provide a quicker and more positive wiring connection and code required wiring supervision.The C01224T detector offers a low current draw,allowing more devices to be connected to the panel without having to purchase a more expensive panel or an extra power supply. The C01224T model will operate on most industry security and fire Agency Listings alarm control panels because it is is a 12/24VDC detector. U` LISTED �o�s C01224T Carbon Monoxide Detector Specifications Carbon monoxide detector shall be a System Sensor model number C01224T,listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The detector shall be equipped with a sounder and a trouble relay.The detector's base shall be able to mount to a single-gang electrical box or direct (surface)mount to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide dual color LED indication,which blinks to indicate normal standby,alarm,or end-of-Iife.When the sensor supervision is in a trouble condition,the detector shall send a trouble signal to the panel.When the detector gives a trouble or end-of-life signal,the detector shall be replaced.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA(75 mA test) Alarm Contact Ratings 0.5 A@ 30 VDC Trouble Contact Ratings 0.5 A@ 30 VDC Size Length:5.1 in,Width: 33 in,Height:13 in Approximate Weight 7 oz Operating Temperature Range 32°F to 104°F(0°C to 40°C) Operating Humidity Range 22 to 90%RH InputTerminals 14 to 22 AWG Mounting Single gang back box;surface mount to wall or ceiling Operation Modes .. - � - � Normal(standby) Blink 1 per minute — — Alarm — Blink in temp 4 pattem Sound in temp 4 pattern RealTest""Feature: The System Sensor C01�24T carbon monoxide detector with RealTest` can evaluate the functionality of the CO sensing cell using canned tcst agent. - • • <� '� _ � � \ � i ^ � � �� r � I� � �: � 0 Push and hold theTest/Hush button for Spray canned CO agent Into the detector. Verify CO sensing at the control panel.The two seconds to enter RealTest mode.The detector will automatically exit RealTest green LED will flash once every second to alarm mode after about 20 60 seconds. indicate RealTest mode has started. NOTE:Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an Installation. Hush Feature: Pushing theTest/Hush button will silence the sounder for S minutes(except in RealTest mode). Trouble Feature: When the detector is in a trouble condition,it will send a trouble signal to the panel. End of IifeTimer: After the detector's internal sensor has reached the end of its life,a trouble signal will be sent to the panel.This will indicate that it is time to replace the detector.An electrochemical carbon monoxide detector lifespan is approximately six years,and the detector must be replaced by the date marked on the inside of the product. Ordering Information �- C01224T 12/24 volt,4 wire system monitored carbon monoxide detector with RealTest""Technology �� SYSTEM ozoo8 sy,em sen=o�. w, 3825�h10 f�V2YlUe•St.�{ldY�eS,��6�174 ?roductspe6�ca�onssub�rcttorn gcwithoutnotrce.uis�sysremsensor.comfor �' �l' SE/�/SOR Ph0112:8��-SENS�RZ•FdX:63�-3��-6495 cwren[producUnfom�ation,lndudingehelacestversionofthlsdatasheet. � A05-0437-000•8/OS•H1953 �� SYSTEM � ��� SENSOR° �` -___.� � , '� BI 5600 Series Mechanical � ` Heat Detectors ��� � � + _� � . _ ...s. � � �, System Sensor's 5600 series mechanical heat detectors '� offer a low-cost means for property protection against ; � � fire, and for non-life-safety installations where smoke �` � ,,� detectors are inappropriate. `__ ?�,������� �':-` - , Features Multiple configurations.The 5600 series offers a full-line of •Multiple configurations for installations configurations to accommodate a broad range of applications.Both —Single-and dual-circuit models single-and dual-circuit models are available for low-and high- —Fixed temp and combination fixed-temp/rate-of-rise temperature ratings with either fixed temperature or combination 135°F or 194°F ratings. fixed temperature/rate-of-rise(ROR)activation.The ROR element of the fixed/ROR models is restorable to accommodate field-testing. •Plain housing for residential installations(Model 5601 P) •Easy-to use terminal screws Installation flexibility.To satisfy a variety of installation needs, •A broad range of back box mounting options: the 5600 series easily mounts to single-gang and octagonal back —Single gang boxes.And these models accommodate four-square back boxes, —3.5""and 4"Octagonal when used with a square to round plaster ring.The reversible —4""square with square to round plaster ring mounting bracket permits both flush-and surface-mount back box installations. •Reversible mounting bracket Visual identification.The 5600 series provides dear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric characters identify the activation method,as well as the temperature rating,in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX,while combination fixed/rate of-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.When the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings � u� F M MEA «(�� a roved ��'°°'° LISTED APPROVED pp s_,oi io,aoce i.�-os-e ;zio-;zo���zz, Specifications Mechanical heat detector shall be a System Sensor 5600 series model number ,listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single circuit or a dual-circuit type,normally open.The detector shall be rated for activation at either 135°F(57°C)or 194°F(90°C),and shall activate by means of a fixed temperature thermal sensor,or a combination fixed temperature/rate-of-rise thermal sensor. The rate of rise element shall be activated by a rapid rise in temperature,approximately 15°F(83°C)per minute.The detector shall indude a reversible mounting bracket for mounting to 3'/z-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterlor of the housing to identify its temperature rating and activation method.The rate of rise element of combination fixed temperature/rate of rise models shall be restorable,to allow for field-testing.The detectors shall indude an external collector that shall drop upon activation to identify the unit in alarm. •. Maximum Installation Temperature 5601 P,5603,5621,and 5623:100°F(38°C) 5602,5604,5622,and 5624:150°F(65.6°Q Operating Humidity Range 5 to 95%RH non-condensing Dimensions with mounting bracket Diameter:4.57 inches(11.6cm) Height: 1.69 inches(43cm) Alarm Temperature 5601 P,5603,5621,and 5623:135°F(57°C) 5602,5604,5622,and 5624:194°F(90°C) Weight 6 oz(170 grams) Rate-of-RiseThreshold 15°F(83°Q rise per minute(models 5601 P,5602,5621,and 5622 only) Mounting 3Yrinch octagonal back box 4 inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring . . Operating Voltage/Contact Ratings 6-125VAC/3A 6-28VDC/1 A 125VDC/03A 250VDC/O.IA InputTerminals 14-22 AWG eoai� xi xi aoaixi O O O O O �4� � � o � � i � i- � 5607P 5602,5622 5603,5623 5604,5624 5621 Ordering Information - - � 5601 P Single None 135°F(57°C) Fixed Temperature/Rate of Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(1524m x 152m) 5603 Single Lettering 135°F(57°Q Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual Lettering 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(1524m x 152m) 5622 Dual Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(1524m x 15Zm) 5623 Dual Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5624 Dual Lettering 194°F(90°Q Fixed Temperature 25 feet x 25 feet(7.62m x 7b2m) *NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. l\��� �\��� �ZOCE �_tc n Sen� �� �� 3825 Ohio Avenue•St.Charles,IL 60174 ��a��rspe<�fi��o�ss�u,��<<o�rz ge �mou�,���<e.u�s��sys�emsenso�-�omro� ��� �����R� PhOIl2:80�-SENS�RZ•FdX:63�-3��-6495 currenrproduainformation,�mdudingthelares[verslonofthlsdatasheet. A05-0351-002•11/06•i31676 I I I �� � � 5800WAVE WIRELESS SIREN � Honeywell's 5800WAVE is a fully wireless siren that provides periodic status information and battery back up for an added level of performance and protection. The flexible design simplifies installation, saves time and installs in seconds at any location without the need to run wires. System status is shown on the 5800WAVE with three LED's directly on the front of the unit. FEATURES • Siren output level is 95 dB at three feet • AC powered with a rechargeable • Lowers labor costs and 12 hour battery backup saves time •Transmits module status, including mounting tamper, low battery and • Plugs in to any standard duplex • Simplifies installation AC loss to the control panel receptacle and installs in seconds • Compatible with LYNXR (Rev 10 • LED; show system status of the device • Provides temporal pulse sounding for or higher) and VISTA controls that fire alarms support the 5883 transceiver SPECIFICATIONS • Dimensions: 4.5" W x 7.5" H x 2.25" D • Frequency of Operation: 345 MHz • Current: 202mA Typical (114mm x 191 mm x 57mm) • Input Voltage: 120VAC • Operational Temperature • Output Level: 95 dB at three feet 32° F to 122° F(0°to 50°C) ORDERING 5800WAVE Wireless Siren Honeywell Security&Communications Honeywell Hon���ll 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 vaaaowAV�� March 2008 www.honeywell.com oO 2008 Honeywe�l Internationa�Inc. �� SYSTEM ��� SENSOR° � ��� � �. � � �ir .__�� � + _1 �. e �'°� Selectable Out ut 4'�� p � � Horns, Strobes, and � �-;:�. � Horn/Strobes = , _ a .`, � � SpectrAlert°Advance selectable-output horns,strobes, � ���° and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTfl��C� A V A E The SpectrAlert Advance series of notification appliances is Features designed to simplify installations,with features such as plug in .Electrically compatible with existing SpectrAlert products designs,instant feedback messages to ensure correct installation of individual devices,and 11 field-selectable candela settings for wall 'Automatic selection of 12 or 24-volt operation at 15 and 15/75 and ceiling strobes and horn/strobes. candela •Plug-in design When installing Advance products,first attach a universal mounting •Field selectable candela settings on wall and ceiling units: 15, 15/75, plate to a four-inch square,four-inch octagon or double-gang 30,75,95,1 10,1 15,135, 150,177, 185 junction box.The twawire mounting plate attaches to a single-gang .Same mounting plate for wall-and ceiling-mount units junction box. •Shorting spring on mounting plate for continuity check before Next,connect the notification appliance circuit wiring to the SEMS installation terminals on the mounting plate. •Tamper resistant construction •Outdoor wall and ceiling products rated from—40°F to 151°F Finally,attach the horn,strobe or horn/strobe to the mounting plate .Design allows minimal intrusion into the back box by inserting the product's tabs in the mounting plate's grooves.The .Horn rated at 88+dbA at 16 volts device will rotate into position,locking the product's pins into the mounting plate's terminals.The device will temporarily hold in place •Rotary switch for hom tone and three volume selections with a catch until it is secured with a captured mounting screw. •Outdoor products UL listed to UL 1638(strobe)and UL 464(horn) outdoor requirements The SpectrAlert Advance series indudes outdoor notification .Outdoor products rainproof per UL 50(NEMA 3R) appliances.Outdoor strobes and horn/strobes(two wire and four wire)are available for wall or ceiling.Outdoor horns are available for •Compatible with MDL sync module wall only.All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. /�g@nCy LISt111g5 SIGNALING �. 7175-�653�86(InGocr strobes) � 7;Oo-1653187(ou�doorsvobes) u� F nn MEA � „�,�„5,,88�h�r,,,,�r�,bFs �. �n���»e,s�,oees� approved ,,;s-,es3,a9mo��s,�n��mes> LISTED APPROVED 5401' 30i3S/7 MCA4S7-US-i �, 53593 SpectrAlert Advance Specifications General SpectrAlert Advance horns,strobes and horn/strobes shall mount to a standard 4 x 4 x 1 Yz-inch back box,4-inch octagon back box or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 1'/a-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Syno-Circuit"'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Syno-Circuit Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.Strobes and horn/strobes shall have field-selectable candela settings induding 15,15/75,30, 75,95,1 10,115,135,150,U7,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary signaling noiification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous) pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box wlth half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Syno-Circuit model MDL Ilsted to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and homs at temporal three.Also,while operating the strobes,the module shall silence the homs on horn/strobe models over a single pair of wires.The module shall mount to a 4��/,6 x 4��/,b x 2'/e-inch back box.The module shall also control two Style Y(dass B)clrcuits or one Style Z (dass A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F(0°C to 49°C) K Series Operating Temperature —40°F to 151°F(-40°C to 66°q Humidity Range 10 to 93%non condensing(indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Ranqe� 8 to 175 V(12V nominal)or 16 to 33 V(24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions(including lens) 6.8""diameter x Z.5""high(173 mm diameter x 64 mm high) Wall mount dimensions(including lens) 5.6°L x 4J"1N x 2.5`D(142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.6°L x 4J'1N x 13`D(142 mm L x 119 mm W x 33 mm D) Wall-mount back box skirt dimensions(BBS-2,BBSW-2) 5.9°L x 5.0"W x 2.2`D(151 mm L x 128 mm W x 56 mm D) Ceiling-mount back box skirt dimensions(BBSG2,BBSCW-2) 7.1""diameter x Z.25""high(180 mm diameter x 57 mm high) Wall-mount weatherproof back box dimensions(SA-WBB) 5J"L x 5.1"1N x 2.0`D(145 mm L x 130 mm W x 51 mm D) �eiling-mount weatherproof back box dimensions(SA-WBBC) 7.1""diameter x Z.0""high(180 mm diameter x 51 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time varying power source that is used on some power supply and panel outputs. 2.P,5,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-003 UL Current Draw Data . � 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern d6 DC FWR DC FWR Standard 15* 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75* 142 148 77 81 Temporal Medium 44 49 58 69 30* NA NA 94 96 Temporal Low 38 44 44 48 75* NA NA 158 153 Non-temporal High 57 56 69 75 95* NA NA 181 176 Non temporal Medium 42 50 60 69 110 NA NA 202 195 Nomtemporal Low 41 44 50 50 115 NA NA 210 205 Coded Hlgh 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 �andela Range �50 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 - � - 8-17.5 Volts 16-33 Volts DClnput 15 75/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non temporal High 141 152 91 100 116 176 201 221 229 Non temporal Medium 133 145 75 85 102 163 187 207 216 Non temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non temporal High 142 161 103 112 126 181 203 221 229 Non temporal Medium 134 155 85 95 110 166 189 208 216 Non temporal Low 132 154 80 90 105 161 184 202 211 . 16-33 Volts 16-33 Volts DClnput 135 150 177 185 FWRlnput 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed candela �. � ratings must be reduced in accordance with this table. .- • 8-17.5 16-33 24 Volt Nominal Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at-40°F Position Sound Pattern d6 DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32°F z Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non temporal High 82 82 88 88 93 92 100 100 95 �� 5 Non temporal Medium 78 78 85 85 90 90 98 98 110 >>0 6 Non temporal Low 75 75 81 81 88 84 96 92 115 >>5 7t Coded High 82 82 88 88 93 92 101 101 135 135 gt Coded Medium 78 78 85 85 90 90 97 98 150 150 9' Coded Low 75 75 81 81 88 85 96 92 ��� ��� =Settings 7,8,and 9 are not available on 2-wire horn/strobe. 185 185 A05-0395-003 SpectrAlert Advance Dimensions �4.7" 2.5" 6.8" ..-,��. Dia. i � � �� — // �\ 4 � — �o ����, � ���� � � �� 2.5„ 5.6" � � \\ \� �=—�i � � �' `'�- Wall-mount horn/strobes Ceiling-mount horn/strobes 225" � 71„ 7.1" � � 2.0"" Dia. 5.05� �2.23� Dia. � � � � ��� � � � ° � / � � z.o�� OOoa� �r 5.98„ � 5.7" � 0 O O h o O ayw O � � � � o � O ll � � �5.1"� Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information �- �� Wall Horn/Strobes Ceiling Horn/Strobes(conYd.) P2R�' 2-wire Horn/Strobe,Standard cd$,Red PQW*' 2-wire Horn/Strobe,Standard cd,White P2RH" 2-wire Horn/Strobe,High cd,Red PC2WH*� 2-wire Horn/Strobe,High cd,White P2RK* 2-wire Horn/Strobe,Standard cd,Red,Outdoor PC4R 4-wire Horn/Strobe,Standard cd,Red P2RHK* 2-wire Horn/Strobe,High cd,Red,Outdoor PC4RH 4wire Horn/Strobe,High cd,Red P2W* 2-wire Horn/Strobe,Standard cd,White PC4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor P2WH� 2-wire Horn/Strobe,High cd,White PC4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor P4R* 4-wire Horn/Strobe,Standard cd,Red PC4W 4-wire Horn/Strobe,Standard cd,White P4RH* 4-wire Horn/Strobe,High cd,Red PC4WH 4wire Horn/Strobe,High cd,White P4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor Ceiling Strobes P4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor SCR� Strobe,Standard cd,Red P4W* 4-wire Horn/Strobe,Standard cd,White SCRH� Strobe,High cd,Red P4WH* 4-wire Horn/Strobe,High cd,White SCRK Strobe,Standard cd,Red,Outdoor Wall Strobes SCRHK Strobe,High cd,Red,Outdoor SR*' Strobe,Standard cd,Red SCWx' Strobe,Standard cd,White SRH*� Sirobe,High cd,Red SCWH�' Strobe,High cd,White SRK Strobe,Standard cd,Red,Outdoor Horns SRHK Strobe,High cd,Red,Outdoor HR Horn,Red SW* Strobe,Standard cd,White HRK Horn,Red,Outdoor SWH* Sirobe,High cd,White HW Horn,White Ceiling Horn/Strobes Accessories PC2R* 2-wire Horn/Strobe,Standard cd,Red BBS-2 Back Box Skirt,Wall,Red PC2RH�" 2-wire Horn/Strobe,High cd,Red BBSW-2 Back Box Skirt,Wall,White PC2RK 2-wire Horn/Strobe,Standard cd,Red,Outdoor BBSG2 Back Box Skirt,Ceiling,Red PC2RHK 2-wire Horn/Strobe,High cd,Red,Outdoor BBSCW-2 Back Box Skirt,Celling,White Notes: *Add"-P°to model numberfor plain housing(no"FIRE"marking on cover),e.g.,P2R-P t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP �°Standard cd;'refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd;'refers to strobes that indude 135,150,177,and 185 candela settings. All outdoor units ending in"K"indude a weatherproof back box. ��� �\��� �ZO('E �_tc n Sen� �� 3825 Ohio Avenue•St.Charles,IL 60174 ��a��rspe<�fi��o�ss�u,��<<o�rz ge �mou�,���<e.u�s��sys�emsenso�-�omro� ��� �����R� PhOIl2:80�-SENS�RZ•FdX:63�-3��-6495 currenrproduainformation,�mdudingthelares[verslonofthlsdatasheet. A05-0395-003•12/06•i31676