Loading...
HomeMy WebLinkAboutDRB110014-A1 T.O.SUBFLR EL:8468'-7.375�� PRELIMINARY LIGHTING NOTES : FLOOR PLAN NOTES : T,O,PLATE ' � EL:8467'-9.125" 1. ALL LOW-VOLTAGE TRANSFORMERS, IF INCLUDED IN WORK, SINGLE FAMILY RESIDENCE TO CONFORM TO CURRENT IBC AND IRC L N N � � SHALL BE REMOTE AND LOCATED NO FURTHER THAN 20'-0" FROM BUILDING CODES. PROVIDE 1-HOUR RATED WALLS AND CEILINGS OF B Q C a POWER FEED. ALL LOW-VOLTAGE TRANSFORMERS SHALL BE GARAGE, MECHANICAL ROOM, BACK STAIRWELL, AND CLOSET & � � � Q-TRAN AND SIZED BY ELECTRICAL CONTRACTOR. IT IS THE STORAGE UNDER STAIRWELL. USE 2 LAYERS 5/8" TYPE X GYPSUM � S T D I O EXISTING CRAWLSPACE GRADE � EXISTING CRAWLSPACE GRADE � RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO LOCATE BOARD. DOORS SEPARATING THESE ROOMS FROM RESIDENCE TO BE ° AND INSTALL ALL LOW-VOLTAGE TRANSFORMERS PER NEC AND o ARCHITECTURE + DESIGN RATED. ALL GRADE AT EXTERIOR WALLS TO SLOPE AWAY FROM DENVER + EDWARDS 0 LOCAL JURISDICTIONAL REQUIREMENTS. VERIFY TRANSFORMER HOUSE. � 970.376.Z575 ;, LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. � 2456 Race.Denver.00.80205 � ALL WOOD-FRAMED WALLS TO BE 2X6 CONSTRUCTION UON. Q POB.4326.Edwards.00.81632 2. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE Q www.aja-studio.com � andrew@aja-studio.com INSTALLATION OF FIXTURE TYPE "PL" (PUCK LIGHT), IF INCLUDED SEE STRUCTURAL DRAWINGS FOR ALL FRAMING DETAILS. ¢ �Qcopyright A]A Studio PC 2008 PROPOSED SLAB: SEE STRUCTURAL DRAWINGS PROPOSED SLAB: SEE STRUCTURAL DRAWINGS F- 7,O,PROPOSED SLAB IN WORK, WITH THE INTERIOR ARCHITECTURAL AND LIGHTING STRUCTURAL DETAILS TO RULE FOR FRAMING SIZES AND z EL:8458'-9.125" ELEVATIONS. A FALSE BOTTOM TO BE DESIGNED FOR THE � CONNECTIONS. IF CONFLICT BETWEEN ARCHITECTURAL AND INSTALLATION OF THE UNDER CABINET "PL" FIXTURES, IF STRUCTURAL DETAILS ARE IDENTIFIED, CONTACT ARCHITECT FOR v INCLUDED IN WORK. ALL REMOTE LOW-VOLTAGE TRANSFORMERS CLARIFICATION. � TO BE PER NEC AND LOCAL JURISDICTIONAL Q Z Z Z SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ALL � A � D � C � 3. ALL DIMMERS AND FACE PLATE FINISHES TO BE APPROVED BY RELATED INFORMATION. VERIFY EQUIPMENT WITH APPROPRIATE E � � � � � INTERIOR DESIGNER PRIOR TO PURCHASE. ELECTRICAL DOOR ACCESS CONTACT ARCHITECT FOR ON SITE COORDINATION � O � � � CONTRACTOR TO SIZE ALL DIMMERS FOR THEIR CORRECT LOAD AS NECESSARY. o �° �° �° TYPE, TOTAL WATTAGE AND DURATION AS REQUIRED. � �� EXISTING CRAWLSPACE GRADE � EXISTING CRAWLSPACE GRADE � � '� EXISTING ALL COUNTERS TO BE 36" ABOVE FINISHED FLOOR (AFF) UNLESS v � CRAWLSPACE GRADE 4. THE ELECTRICAL CONTRACTOR SHALL LOCATE OUTLETS. OTHERWISE NOTED (UON). KITCHEN CABINET CONSULTANT TO � � ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED POWER TO ALL PROVIDE CABINET DRAWINGS. ALL KITCHEN BASE CABINETS TO BE � O APPLIANCE RECEPTACLES APPROPRIATE. STANDARD 24" UON. ALL KITCHEN UPPER CABINETS TO BE 3 STANDARD 15" UON. ALL BATHROOM BASE CABINETS TO BE o � M 5. ALL 3-WAY SWITCHES TO BE DIMMERS. THE DIMMERS SHOWN STANDARD 21" CABINETS UON. � �. � PROPOSED SLAB: SEE STRUCTURAL DRAWINGS PROPOSED SLAB: SEE STRUCTURAL DRAWINGS WITH A DESIGNATION m# AND CORRESPONDING r# INDICATE � � f6 � .� PROPOSED GRADE MULTI-LOCATION DIMMERS. THE "m" INDICATES A PRESET SMART ALL GUARDRAILS AT 37" AFF. ALL STAIR RAILINGS AT 34-38" ABOVE � � > — � O PROPOSED SLA6: SEE STRUCTURAL DRAWINGS DIMMER AND THE DESIGNATION r# INDICATES A SMART REMOTE TREAD NOSING. SEE STAIR DRAWINGS. o � '> � DIMMER. NOT FOR USE WITH 3-WAY MECHANICAL DIMMERS. v � � � � O C R A W L S P A C E I N T E R I O R E L E V A T I O N S : E x i s t i n g W I N D O W S & D O O R S: E X I S T I N G W I N D O W S A N D D O O R S T O R E M A I N Q � L � � O 3 6. ALL RECEPTACLES, PHONE, DATA & LIGHTING SWITCHES SHALL �' � (, (n U UNLESS UON. CLEAN AND REPAIR IF NECESSARY TO ACHEIVE GOOD o 24x36: SCALE: 1��=4� VERIFY FOOTERS PER STRUCTURAL - TYP. HAVE COORDINATED FACE PLATES TO MATCH EXISTING(UON). WORKING CONDITION. NOTIFY ARCHITECT IF ANY WINDOWS, DOOR � � � � L _ I 1 X 1 7: S C A L E: 1��=H� H 4 2 O A N D/O R H A R D W A R E N E E D T O B E R E P L A C E D. P R O V I D I N G M A T C H I N G E � •— 7. ALL EXISTING FIXTURES THAT ARE REMOVED IN DEMOLITION � � M �- _ � REPLACEMENT WINDOWS/DOORS AND NEW WINDOWS/DOORS IN u 5� 5-$� 4� S H A L L B E C L E A N E D A N D R E T U R N E D T O O W N E R. A L L E X I S T I N G THE ADDITION. SEE BELOW FOR EXISTING, RELOCATED AND NEW � N �> SEE ELEVATION 3'-0° i'-a" i'-a" � 3'-0° FIXTURES THAT REMAIN IN AREA OF WORK AFTER CONSTRUCTION LOCATIONS. ALL NEW WINDOWS/DOORS TO MATCH EXISTING IN `� � �' �' '— DIRECT VENT DIRECT VENT p SHALL BE CLEANED AND RELAMPED PRIOR TO JOB COMPLETION. TypE, CONSTRUCTION, MATERIAL, COLOR UON. SEE OWNER FOR � J � �o ' � RE-USE OF EXISTING HARDWARE. � `° `° 8. EXISTING BATHROOM FANS SHOULD BE USED IF APPLICABLE. -a n , � �� ' ' ° 2 �� E URAL 2�6X7'0 2' X6'8 , THE ELECTRICAL CONTRACTOR SHALL UNINSTALL CLEAN AND �° �� a 6 N ' ' � � New windows / doors - see elevations and floor plans. � V w � � � U ION REINSTALL THE EXISTING FANS. DO AMING Existin windows/ doors to be Relocated or Removed and saved. '�, � � � o'� F NEC ARY gq H IF FANS ARE NOT USABLE, CONTRACTOR TO MAKE FAN g -°'o � _ �y_ ___ _ -- --- - - r, Existing windows / doors to remain per drawings. � � Q , , , �Q , TI E , RECOMMENDATION TO ARCHITECT. � � O NI� I NEW & PATCHED WALLS: ° � ° H EA�'RTH - ' ' H EAd'RTH g � 10. ELECTRICAL CONTRACTOR TO VERIFY ALL LIGHTING FIXTURES � r /1 SOUND INSULATION: _c T �-- V J 9� �G F W �p `° AND LOCATIONS WITH OWNER ON SITE. ALL FIXTURES TO BE EXTERIOR WALL INSULAITON: �, 'L LOCATED PER DRAWINGS. WHEN NOT DESIGNATED ON DRAWINGS RIGID INSULATION: �' 2'-0" 2'-0" 2'-0" ALIGN HEARTH WITH WALL �2�_0^ ALL FIXTURES TO BE CENTERED & SYMMETRICAL. NOTIFY °' � , , �F CONCRETE FORMWORK: 0 0 N 2'-s° Ea EQ 2'- ARCHITECT OF ANY DISCREPANCIES. BRICK VENEER: ;�;%���;�% L � - - + - - I 2'CAR GARAGE 11. ALL SCONCES TO BE MOUNTED AT 6 -0 UNLESS OTHERWISE � MECH MECH TEMPERED WINDOW: VIF TO � ' EXISTING ' EXISTING EXISTING NOTED (UON). ALL COUNTERTOP OUTLETS TO BE MOUNTED WITH EGRESS WINDOW: E �L � � FACE PLATE JUST ABOVE TOP OF BACKSPLASH. ALL SWITCHES TO � 5 SMOKE ALARM: OS o � � BE MOUNTED 48 ABOVE FINISHED FLOOR (UON). ALL MOUNTING v �' ' ' HEIGHTS MUST BE ALLOWED BY CODE. NOTIFY ARCHITECT OF ANY EXTERIOR LIGHTING NOTES: v 1�,�ti ��,�ti�� DISCREPANCIES. See Elevations for general Fixture locations. Some fixtures may be � � � � �'I- � �'I- behind structural posts. See cutsheets for light fixtures. All fixtures to �' 12. THE ELECTRICAL CONTRACTOR SHALL REVIEW ALL LIGHTING obscure light bulbs. No exterior uplights are proposed in this project. � � MUDROOM � MUDROOM PLANS AND INTERIOR SPECIFICATIONS PRIOR TO COMMENCEMENT � j EXISTING EXISTING 3'OX7'0 EXISTING EXISTING TYPE OF EXTERIOR FIXTURES: o � OF WORK. A �} EXT. A: WALL MOUNTED FIXTURE Q �\ ' � ' VERIFY ALL LIGHTING AND SWITCH LOCATIONS WITH EXISTING g � EXT. B: CEILING MOUNTED FIXTURE v � FAMILI� ROOM � FAMILI� ROOM CONDITIONS. ELECTRICAL CONTRACTOR TO MAKE Ca EXT. C: RECESSED WALL STEP LIGHT � w 9 �LG UP �+r WC�OD � UP �+r RECOMMENDATIONS FOR REDUNDANT CONDITIONS. p� EXT. D: PENDANT FIXTURE � ' � `r�',r2 I `r�'.r2 E � EXT. E: LANDSCAPE FIXTURE � i i � Q ' ' `" PRELIMINARY LIGHTING LEGEND : EXTERIOR WALL PACKAGES : � , ADJUST L G IF MECH , r H OFFIT US D IN ROO C�T , � C�T � CEILING MNTD FLUSH FIXTURE ° --- EXISTING � EXISTING �=-1 CEILING MNTD PENDANT EXTERIOR WALL PACKAGE #1: � —�—-—- � � � `° ' ' cn }�, WALL SCONCE BRICK WITH AIR SPACE Q N Q EQ 3�9�� 2'-6" 2'-6" 3'-9}" ..� Y' w Q RECESSED DOWNLIGHT WATERPROOF MEMBRANE Q SOFFIT SOFFIT SOFFIT 8' SOFFIT 8' SqFFIT 8' SOFFIT � RECESSED LOW-VOLTAGE DNLT %4" WALL SHEATHING z 8'6CLG 8'6CLG 8'6CLG UP NSNO ALCOVE ' ALCOVE UP � � �- RECESSED WALL LIGHT 2X6 WOOD FRAME WALL - SEE STRUCTURAL � O� • 0�.2011 , • UNDERCAB. PUCK LIGHT (PL) BATT INSULATION � T LAN�ING � (2) 2'�6X7'0 LAN�ING o INCABINET PUCK LIGHT (PL) 6MIL POLYETHYLENE VAPOR BARRIER � TOWN REVIEW & � EXI TING ' T.O.FIN.FLR. � w EXI TING Q WELL LIGHT 5/$" GYPSUM BOARD z PERMIT SET RELEASE w � ENTRY EXSTG.W,�LL LCTN. w 2) 2'6X7� EL:100.0' O m EXSTG.W,�LL LCTN. � RECESSED VANITY COVE FIX. _ � � 9'CLG $�C� ' I EN RY � v 37"AFF GRDR o CEILING MTD 1'X4' FLUOR. FIX. EXTERIOR WALL PACKAGE #2: } � � WALL-MTD. CLOSET FLOUR.FIX. SIDING: SEE ELEVATIONS o � + --- UP � ° - -�- ST NE LANDIN � UNDERCAB. INCAND. FIX. WATERPROOF MEMBRANE v o UP Ts 1 " WOOD = � LINEAR INCAND. CLICKSTRIP %4" WALL SHEATHING o � � - --- �; � i� � @ .5" VI T.O.FIN.FLR. °' T❑ THERMOSTAT 2X6 WOOD FRAME WALL ISSUE DATE DESCRIPTION: , LANDIN o EL:1050'VIF " H❑ HUMIDISTAT - SEE STRUCTURAL 3.3.2011 PERMIT SET , VIF CLG ``� � ANDR L 3 .5' A OV NOSING �❑ VACUUM BATT INSULATION � A � '6X7' '6X7' Eq SEE EL VATION EQ "� HEAT LAMP /MGYPSOUM BOARD E VAPOR BARRIER T. .FIN.FL . Q INTERCOM s �� z 2�_� ��_6• ��_s• �'�9 g5 ��_6• 2'-2�" } a'-s}^ 3�_9�• PROVIDE RAILING PER CODE ABOVE A❑ AUDIO/SOUND/SPEAKERS 8 Q MATCH EXISTING RAILING MATERIALS = THESE TWO LOCATIONS 4. �3�• �^ s° s" �" RAILING SPACING LESS THAN 4" TYP �❑ DOORBELL/ CHIME Architect's Permit Set is valid for (1) � � W 3'-11�" 4'-1" VIF > > FQ EXHAUST FAN year from Permit Set Release Date O O i a'-o" a'-o" 2 -�- CEILING-MTD FAN / LIGHT or until Governing Codes require X w T.O.FIN.FLR. X W REMOVE EXISTING AZ w � 0 KEYPAD changes, whichever comes first. W Q EL:99.5' � Q W EXT. STAIRS THIS AREA ° J J a This set is only valid for 4223B a a E E a a p SEE STRUCTURAL � SMOKE ALARM / SOUNDER � w � w � Spruce Way, Vail, Colorado; � � � � � FLAGSTONE � WALL SWITCH Eagle County. � ; ENTRY TERRACE � �; ENTRY TERRACE 32 SF a a �° WALL SWITCH DIMMER � z DRIP-THRU DECK ABOVE WALKWAY ° � z FLAGSTONE WALKWAY � � ° DRIVEWAY �" 3-WAY SWITCH-MASTER � � � � � 160 SF EXISTING ASPHALT �R 3-WAY SWITCH-REMOTE JOB NO: 2010.01 z w z w DR DOOR JAM SWITCH cn cn �� GROUND FAULT INTERRUPTER � 589 SF EXISTING GARAGE 2 DRAWN BY: AJA S3 A3 � WALL OUTLET SHEET NUMBER: � � EXISTING COLUMNS ° � SWITCHED WALL OUTLET m DECK ABOVE J DECK ABOVE VERIFY LOCATIONS w � GRADE +98 � � FLOOR OUTLET z z EL:99.0' �r+ TOPO NOT PROVIDED R. PROVIDED � SWITCHED FLOOR OUTLET O POSITI AGE FROM HOUSE TO EDGE OF � WALL TELEPHONE OUTLET (NEIGHBOR) rn ERRACE AT 1"/12" THEN FROM EDGE OF � FLOOR TELEPHONE OUTLET ENTRY LEVEL DIAGRAM Entry Level Preliminary Lighting Plan TERRACE TO EXISTING GRADE AT 1'/4' AND ENTRY LEVEL FLOOR PLAN � QUADRUPLEX OUTLET � " 1 MEETTO REMA NI ON�SI EE ROP RTYD�APNAGE " ' �� WATERPROOF DUPLEX OUTLET A2 24x36: SCALE: 1 =4 24x36: SCALE: 1 =4 C5 CAT5 CABLE INTERNET OUTLET �Renovation 11X17: SCALE: 1��=8� $ 4 2 � 11X17 : SCALE: 1��=8� $ 4 2 0 Spruce Way Crawlspace Renovation NOTTOSCALE ENTRY LEVEL FLOOR PLAN