HomeMy WebLinkAboutB11-0226 . .w+-•. 10-28-2011 Inspection Request Reporting P ge 2 7:36 am Vail. CO - Citv Of __ Requested Inspect Date: Friday, October 28, 2011 Site Address: 227 6RIDGE ST VAIL Covered Bridge Building, Unit F A/P/D Information Activity: 611-0226 Type: COMBO Sub Type: ACOM Status: ISSUED Const Type: Occupancy: Use: M Insp Area: Owner: COVERED BRIDGE INC Contractor: RETAIL CONSTRUCTION SERVICES INC Phone: 651-704-9000 Description: TENANT FINISH: NEW DISPLAY FISTURES, FITTING ROOMS AND SMALL STOCK ROOM Requested Inspection(s) Item: 90 BLDG-Final Requested Time: 01:30 PM Requestor: Phone: C o m m e n t s: 408-540-8154 Assigned To: JMONDRAGON Entered By: MHAEBERLE K Action: Time Exp: Item: 290 PLMB-Final Requested Time: 03:00 PM Requestor: Phone: Com ments: 408-540-8154 Assigned To: JMONDRAGON - Entered By: MHAEBERLE K Action: Time Exp: Item: 390 MECH-Final Requested Time: 02:30 PM Requestor: Phone: Com ments: 408-540-8154 Assigned To: JMONDRAGON Entered By: MHAEBERLE K Action: ime Exp: � � � Inspection History � Item: 120 ELEC-Rough '"Approved'" �b� 09/20/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION � / Comment: wafls only � 09/29/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH-Rough *'Approved " i 09/29/11 Inspector: sgremmer Action: AP APPROVED , Comment: Item: 224 FIRE-ALARM ROUGH Item: 225 FIRE-SPRINKLER ROUGH Item: 30 BLDG-Framing "Approved "' 09/20/11 Inspector: JRM Action: PI PARTIAL INSPECTION , Comment: APPROVED AREAS THAT DO NOT CONTAIN ELECTRICAL I OTHER FRAMING AREA APPROVED 10/05/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 50 BLDG-Insulation Item: 60 BLDG-Sheetrock Nail '*Approved"' I 10l07/11 Inspector: JRM Action: PI PARTIAL INSPECTION Comment: PARTIAL ALL EXCEPT FOR ADA AREA 10/07/11 Inspector: JRM Action: AP APPROVED Comment: REPT131 Run Id: 13693 � NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL T/MES ,. ��vo���; . Town of Vail, Community Development, 75 South Frontage Road,Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11-0226 Project #: PRJ11-0372 Job Address: 227 BRIDGE ST VAIL Applied.....: 07/26/2011 Location......: Covered Bridge Building, Unit F Issued. . . : 08/31/2011 Parcel No....: 210108267006 OWNER COVERED BRIDGE INC 07/26/2011 50 E SAMPLE RD STE 400 POMPANO BEACH FL 33064 APPLICANT FRCH DESIGN WORLDWIDE 07/26/2011 Phone:513-241-3000 ATTN: KARL HOALST 311 ELM ST STE.600 CINCINNATI OH 45202-2706 CONTRACTOR RETAIL CONSTRUCTION SERVICES 08/29/2011 Phone:651-704-9000 STEPHEN M. BACHMAN 11343 39TH STREET NORTH LAKE ELMO MN 55042 License: C000003264 Description: TENANT FINISH:NEW DISPLAY FISTURES,FITTING ROOMS AND SMALL STOCK ROOM Occupancy: M Type Construction: IIA Valuation: $110,000.00 ,,...........................................................................,,.... FEE SUMMARY ..........,.......,......,,>.,....._..,.....,...,,,...................,...,..,,.. Building Permit-----------> $1,049.75 Bidg Plan Check----------> $682.34 Use Tax Fee-----------------------> $2,000.00 Electrical Permit---------> $690.00 Elec Plan Check-----------> $448.50 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $300.00 Mech Plan Check---------> $75.00 Additional Fees--------------------> $0.00 Plumbing Permit--------> $0.00 Pimb Plan Check---------> $0.00 Recreation Fee--------------------> $0.00 I nvestigation-----------------------> $0.00 Will Call------------------------------> $15.00 TOTAL PERMIT FEES-------------> $5,370.59 Payments------------------------------> $5,370.59 BALANCE DUE-----------------------> $0.00 ...............�..,..,..........,....,.,............,,,,.,..,,,............>..,..,...........,.......,,.x.........x.................�............................,_,._..__.....�.,....... DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate plot plan,and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:OOAM-4:0 PM� S�� �� '�- - (i - Z_ Signature of Owner or Contractor Date ��� �� ,� �� Print Name combination permit_012811 i .. � �����l1tJ.J = .............,.................,.........,...,....»..,..,...,..,,.....,.....,.......,......_.......,.....,.......................,......................._..........................,,.. CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: 611-0226 Address: 227 BRIDGE ST VAIL Owner: COVERED BRIDGE INC Location: Covered Bridge Building, Unit F ....................................................,......,,......,,,.......,,.,..,......,.......,.�.......,.,........�...............,,.......,...,............,,,,................. combination permit_012811 2 � �o�a�v� � *..**,.***.�**.***.,.,.*..**�*************************************,.***,*******************,.*********.**�******************�*,****,************,.********** REQUIRED INSPECTIONS AND STATUSES Permit#: 611-0226 Address: 227 BRIDGE ST VAIL Owner: COVERED BRIDGE INC Location: Covered Bridge Building, Unit F *«***„*********.********************.********.�****�*,.*,.************«***.*******,.**,.**,.,,****�**,.****,.**********************«««,.***********„***,+****.* Item: 00120 ELEC-Rough 09/20/2011 By: sgremmer Action: PI Comments: walls only Item: 00140 ELEC-Misc. Item: 00200 MECH-Rough Item: 00210 PLMB-Underground Item: 00220 PLMB-Rough/D.W.V. Item: 00224 FIRE-ALARM ROUGH Item: 00225 FIRE-SPRINKLER ROUGH Item: 00230 PLMB-Rough/Water Item: 00240 PLMB-Gas Piping Item: 00260 PLMB-Misc. Item: 00310 MECH-Heating Item: 00320 MECH-Exhaust Hoods Item: 00340 MECH-Misc. Item: 00030 BLDG-Framing 09/20/2011 By: JRM Action: PI Comments: APPROVED AREAS THAT DO NOT CONTAIN ELECTRICAL OTHER FRAMING AREA APPROVED Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail Item: 00070 BLDG-Misc. Item: 00190 ELEC-Final Item: 00228 FIRE- Final Item: 00290 PLMB-Final Item: 00390 MECH-Final Item: 00090 BLDG-Final combination permit_012811 ***+******************+**********************+*****************************************++*** TOWN OF VAIL, COLORADO Statement ***++****************************�*********************��************************+*********+ Statement Number: R110001329 Amount: $110.00 09/27/201111:59 AM Payment Method:Credit Crd Init: SAB Notation: VISA - JOSEPH GUIDO ----------------------------------------------------------------------------- Permit No: B11-0226 Type: COMBINATION BLDG PERMIT Parcel No: 2101-082-6700-6 Site Address: 227 BRIDGE ST VAIL Location: Covered Bridge Building, Unit F Total Fees: $5, 370.59 This Payment: $110.00 Total ALL Pmts: $5,370.59 Balance: $0.00 *****************************+***+************+**��***************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 110.00 ----------------------------------------------------------------------------- NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL T/MES ,�� �w�o���: � Town of Vail, Community Development, 75 South Frontage Road,Vail, Colorado 81657 p.970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11-0226 Project #: PRJ11-0372 Job Address: 227 BRIDGE ST VAIL Applied.....: 07/26/2011 Location......: Covered Bridge Building, Unit F Issued... : 08/31/2011 Parcel No....: 210108267006 OWNER COVERED BRIDGE INC 07/26/2011 50 E SAMPLE RD STE 400 POMPANO BEACH FL 33064 APPLICANT FRCH DESIGN WORLDWIDE 07/26/2011 Phone: 513-241-3000 ATTN: KARL HOALST 311 ELM ST STE.600 CINCINNATI OH 45202-2706 CONTRACTOR RETA�L CONSTRUCTION SERVICES 08/29/2011 Phone: 651-704-9000 STEPHEN M. BACHMAN 11343 39TH STREET NORTH LAKE ELMO MN 55042 License: C000003264 Description: TENANT FINISH:NEW DISPLAY FISTURES,FITTING ROOMS AND SMALL STOCK ROOM Occupancy: M Type Construction: IIA Valuation: $110,000.00 •••••,,'•••••••••••••'••••••••'••"••••••,"•••"••••••••••••"•""•"••••••'"•"••••••• FEE SUMMARY kf�lefRf*4*ftf***�f�Ir**441`ff/�ffR41`1'41'�fR/rir/1`441�41'//*frflkl(1'1`f`**1�*1(4kfitlr#�rt1`Ye1(4fef• Building Permit-----------> $1,049.75 Bldg Plan Check----------> $682.34 Use Tax Fee-----------------------> $2,000.00 Electrical Permit---------> $690.00 Elec Plan Check-----------> $448.50 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $300.00 Mech Plan Check---------> $75.00 Additional Fees--------------------> $0.00 Plumbing Permit--------> $0.00 Plmb Plan Check---------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $15.00 TOTAL PERMIT FEES-------------> $5,260.59 Payments---------------------°-------> $5,260.59 BALANCE DUE-----------------------> 30.00 ......,..................................................,...,,=x,,......=..x..,.,,.,,.,.._........,........,,.,,...........,....,..........,.,......_.........._...............,,.,_........,._... DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate plot plan,and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure according to the town's zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. � REQUESTS FOR INSPECT JN SH BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM-4:00 PM. � , �, �_ , _ �S - � `- 1 1 Signature of Owner Contractor Date `' �.�� � ���; ��� � Print Name combination permit_012811 I � T4���F YA�L . aa#t#'il'�,1'fi1'fYrheYrwh#':YfffNhYrfrwww V�,1'4�k�kNYritf'#'#'#'YrYrYrYhY'rtfY(i44#'trtri4rt+:YRYrYe�R�RrtYrfx�f4xwflrf*fRRf�lLf�t(1��kf4%M1r'kYe�A'�k'k'khk#YrfM'frtf#�A'#�kYrYr W fYrwRxfftrtRtr*#*/�**YtY`A'rt�kkfffrtYfrtiFrtrttrtr4Rlr#�ftr4fff(�r1`1`rtt4Ylf�RY'i4ftrYrWwPewtiwt`1( CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: 611-0226 Address: 227 BRIDGE ST VAIL Owner: COVERED BRIDGE INC Location: Covered Bridge Building, Unit F ........................................................................................�.....,,,...,.,,,,...........,.....,.,.,�,....,....,,...................,,,....,.,.,.....�... combination permit_012811 , # Tf���OF YA� . **************�**�*****�****,,.***�*********************************,�***********�*************.,************�**********��************..***�**��******** REQUIRED INSPECTIONS AND STATUSES Permit#: B11-0226 Address: 227 BRIDGE ST VAIL Owner: COVERED BRIDGE INC Location: Covered Bridge Building, Unit F *„*,,,.****,.******.*«***.******.***�**.*******,.*****.*****„***********„«******,,,,*************,,,,**««******„*,..,,.,.******�*****„****.,.,*,**«««,�«*„*.******** Item: 00120 ELEC-Rough Item: 00140 ELEC-Misc. Item: 00200 MECH-Rough Item: 00210 PLMB-Underground Item: 00220 PLMB-Rough/D.W.V. Item: 00224 FIRE-ALARM ROUGH Item: 00225 FIRE-SPRINKLER ROUGH Item: 00230 PLMB-Rough/Water Item: 00240 PLMB-Gas Piping Item: 00260 PLMB-Misc. Item: 00310 MECH-Heating Item: 00320 MECH-Exhaust Hoods Item: 00340 MECH-Misc. Item: 00030 BLDG-Framing Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail Item: 00070 BLDG-Misc. Item: 00190 ELEC-Final Item: 00228 FIRE - Final Item: 00290 PLMB-Final Item: 00390 MECH-Final Item: 00090 BLDG-Final combination permit_012811 *********++**+************+*�**+******++�*****************�***********�***+�******+++*****�* TOWN OF VAIL, COLORADO Statement *+*************************++********++*+***********************************�**+*****+++**** Statement Number: R110001117 Amount: $4, 578.25 08/31/201103:06 PM Payment Method:Credit Crd Init: SAB Notation: VISA-STEPHEN BACHMAN ----------------------------------------------------------------------------- Permit No: B11-0226 Type: COMBINATION BLDG PERMIT Parcel No: 2101-082-6700-6 Site Address: 227 BRIDGE ST VAIL Location: Covered Bridge Building, Unit F Total Fees: $5,260.59 This Payment: $4, 578.25 Total ALL Pmts: $5,260.59 Balance: $0.00 ****************************************++****+****************************************+***� ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 1, 049.75 EP 00100003111100 ELECTRICAL PERMIT FEES 690.00 MP 00100003111100 MECHANICAL PERMIT FEES 300.00 PF 00100003112300 PLAN CHECK FEES 523 .50 UT 11000003106000 USE TAX 4� 2, 000. 00 WC 00100003112800 WILL CALL INSPECTION FEE 15.00 ----------------------------------------------------------------------------- 311 EL�STREET,SUITE 5;G CIN�INNA�!�H 45202 513.241.3000 �AX 513.241.5��� �R C H . �ES?GN VdORLDVd:JE August 16, 2011 Town of Vaii 75 South Froniage Road West Vail, Colorado 81657 Re: Under Armour Vail Buitding Department Comments 227 Bridge Street B11-0226 .�..��. Mr. Martin A Haeberle, Please find attached a written response to the outlined buiiding department comments. All building department comments have 6een clouded with revision cloud#y; additional changes to #he permit sei have been listed below but have not been clouded per our conversation on 8/15/11. 1} Sheet X1, please pro��ide calculations for the total occupant load utilizing the bathl-ooms showing compliance i�ith Table 29Q2.1 IBC. Sheet X1 has been renamed to sheet A-102. The table 2902.1 has been added and the current occupai�t load has been added. ?) Clarify access to bathrooins is at all times per 2902.3.1 IBC. Bathro�ins in another place of business will nol meet the intent of the code. Sheet X1 has been renamed to sheet A-102. The exiting p}an has added the f7oor above showing the location of the restrooms and accessibility to the restrooms via the stairs and elevator. These bathrooms are public accessible bathrooms for the building. Additianat changes: G-001 —The sheets in the set have been renamed. We have added the foliowing sheets: A-103, A-131, A-302, A-501, A-502, A-503, and A-504. G-001 —The scope of work has been modified to include the exterior louver wark. D2 � � n n/�J�� T N E N E W L� LJ �.I �� E � � GiN � �� :: AUG 1 � 2011 � �� ��� TOWN OF VAIL ��'�� ��' �'� �� -�� . 3i;LLM STRE�T,SUITE 60G �I(YCiNNAT �H 452�2 513.241.3000 FAX 5i32�1.50i5 + r A-102—The Occupant load has changed from 41 occupants to 40 occupants. We have remaved one fitting room and added square footage to storage. A-y04—Added notes to add exterior touvers. A-111 —Removed fitting raom and added square footage to the starage area. A-111 Added a 6ump aut wall for#he TV (located adjacent to the elevator}. A-�17 Maved wall partition schedule to A-1 y 1 sheet and added key notes. A-121 Updated the lighting fixture schedule. A-121 Added general notes and key notes A-141 Added storage fixtures in stock room. A-14� Extended Handicap fitting room bench from 48" ta 6'-7'/z" A-201 Removed Handicap fitting room elevations ta sheet A-4U1 A-4Q1 Added enlarged Handicap fitting room plan and elevations. A-511 Added lighting cove de#ails A-641 Removed partition types from sheet, Please fee!free to contact Karl Hoalst at 513-362-3468 with any questions. Sinc rely, R }'y" �� , . J az ri Karl Hoalst Regi e rchitect Project Manager D (� � ►� (� �/7 � ls f �, LJ \'/ �'°F c°t°,�q � �u� � 6 20» ��� �� "_ TOWN OF VAIL � �A������ * THE NEW * ,��p���� � �- ���� ` E S I G N r,� ��Cs �� ��/f''S �C''�� ��.� �R � ���� ED A - � � �� ��� K � � L KOHRS LONNEMANN HEIL ENGINEERS, PSC � FT.THOMAS EXECUTIVE CENTRE H 153$ALEXANDRIA PIKE,STE.11 E N � 1 N E E R S FT.THOMAS,KENTUCKY 41075 859-442-8050 859-442-8058 Fnx August 15, 2011 104 BROWN STREET DAYTON,OHio 45402 937-220-9700 937-220-9702 FAX Martin A. Haeberle Chief Building Official TWO MIRANOVA PLACE SUITE 280 Town of Vail CowMaus,OHio 43215 75 South Frontage Road West s�a-22$-2iso 614-228-2183FAX Vail, Colorado 81657 RE: Under Armour—227 Bridge St 611-0226 `� Mr. Haeberle, In response to your plan check corrections list dated August 3, 2011 pertaining to the application for permit for the project listed above, we respectfully submit the following responses (in blue italics): Mechanical Comments 1. Sheet M1 - Please clarify outside air intake in relation to property line to adjoining properties. Fire protection may be required. Outside air intakes are not located near adjoining properties. Both new outside air intakes are adjacent to streets. 2. Sheet M4 - Revise mechanical compliance certificate to the 2009 IECC as adopted by the Town of Vail. Mechanical compliance certificates have been updated on M4. Electrical Comments 3. Sheet E4- Revise lighting compliance certificate to the 2009 IECC as adopted by the Town of Vail. Electrical compliance certificates have been updated on E4. Owner Driven Design Changes 1. Sheet M1 —Revised ductwork layout and air device layout due to owner driven lighting/ceiling changes. 2. Sheet M1 —Revised sprinkler head layout due to owner driven lighting/ceiling changes. 3. Sheet M2—Revised fitting room and stock room areas per owner driven changes. 4. Sheet M2—Revised air device schedule per owner direction. 5. Sheet E1 — Revised lighting circuitry, specifications, notation, etc. per owner driven lighting / ceiling changes. 6. Sheet E2—Revised power circuitry, rough-in locations, notation, etc. per owner driven changes. 7. Sheet E3—Revised Electrical Riser Diagram per revised television specification. The television no longer requires a transformer for operation. Also, revised panel schedules per revised loads due to owner drive changes. If we can provide you with any additional information, please do not hesitate to call. Respectfully, KOHRS LONNEMANN HEIL ENGINEERS, PSC , !� C� � [� [l �'1 � � AUG � b 2[l11 � TOWN OF VAIL ��� K ��� ♦ L ♦ H ENBINEERS Robert A. Heil, P.E. Robert A nnemann, P.E. �������������������������������������������������������������������������������������������� TOWN OF VAIL, COLORADOCopy Reprinted on 07-26-2011 at 10:33:41 07/26/2011 Statement �������������������������������������������������������������������������������������������� Statement Number: R110000845 Amount: $682.34 07/26/201110:24 AM Payment Method: Check Init: LC Notation: #146066 / FRCH DESIGN WORLDWIDE ----------------------------------------------------------------------------- Permit No: B11-0226 Type: COMBINATION BLDG PERMIT Parcel No: 2101-082-6700-6 Site Address: 227 BRIDGE ST VAIL Location: Covered Bridge Building, Unit F Total Fees: $5, 260.59 This Payment: $682.34 Total ALL Pmts: $682.34 Balance: $4, 578 .25 �������������������������������������������������������������������������������������������� ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 682.34 ----------------------------------------------------------------------------- . ,. = �' . �N ry "� v" f. k'� �3 3��3 �' 3 �9�� ��.�� ? e 5a` �9 „ r' '���u. 'y�a 3 �£ Z : 3 � \�r 9� 1 i , �: 4 �: �z < ... � ��. ��k�. , . .: . .. . . \ '�� & �� '�3 ` � ��l�l`�lYH�1'��G�v�:D�#ltY�l11'��#�''��/�'�C1�1t18��'a � ,� � � � ,'� g � rr� °�.� `�� ��� � � ' � �� ' .���ar ��., �`7�St�uth F�t�ntage� �'" � �` ��' � p �.�. A � .�A � ��� �� � 4� .. � �r �� r F ���.d'� � �{ ������il II IIII�f��, ��-r ��.� � � q � � . Wl °��` ,,. ��,�`�• �.�s � $ , � �-�'� t `` ,�r `��"� ��`� " :�u "�� �`�����' t���` °De`�el �� � . ,. -t���; - '� $ �� �`' �- � � M ¥; �,, BUILDING PERMIT APPLICATION (Separate applications are required for alarm &sprinkler) __ __ _ ._ Project Street Address: Project#: � '{�� t� � L.7���-- 227 Bridge Street F �1 � ;(Number) (Street) (Suite#) DRB#: `Building/Complex Name: Covered Bridge Building Building Permit#: 1� l r '� 7i�i� �,..ra, .. ,�, .r�,___ a..,�,�,.. r .......�..,,, .,.,.,.,.. Lot#: Block# Subdivision: 'Y Contractor Information Business Name: T•B•�• Work Class: New( ) Addition( ) Alteration(�/) �..._ ... _ __ ..... ':Business Address: T•B•�• Type of Building: 'City T•B•�• State: T.B.D. Zip: T.B.D. Single-Family O Dup�ex O Multi-Family O T.B.D. Commercial(�/) Other( ) ;Contact Name: _ __ . . ..� , Contact Phone: T•B•�• Work Type: Interior(✓) Exterior O Both O D.�M�. .. „ ��� � � ! T.B.D. 'Contact E-Mail: Valuation of ': Contractor Registration Number: T.B.D. �Nork Included Plans Included Work Electrical (�/)Yes ( )No (�/)Yes ( )No $20,000 , ,X� _,� � Mechanical (�/)Yes ( )No (�/)Yes ( )No $15,000 :Owner/Owner's Representative Signature(Required) 'Plumbing ( )Yes (�/)No ( )Yes ( )No N/A h _. . .... _. Project Information Building (�/)Yes ( )No (�/)Yes ( )No $75,000 Owner Name� �MU Management Co., Inc. � Parcel#: 210108267006 Value of all work being performed: $110,000.00 (value based on IBC Section 109.3&IRC Section 108.3� ,(Fa Parcel#,contact Eagle County Assessors Offlce at(970-32&8640 or visit �,243 ' :www.eayiecounry.us�patie) 'Electrical Square Footage ' ... .. ... .,., : ., _. .. , .. , Detailed Scope and Location of Work: Project is in the Covered Bridge Building in Vail Village.Work is a tenant ' improvement only with no plumbing, structural, or exterior work included.Tenant improvements include new display fixtures,fitting rooms, and small stock room. ',(use additional sheet if necessary) For Office Use On : Date Received: Fee Paid: �I[�2•3�( � � [ � � c� Received From: � r�(�%Gv� � D cash Check# i<<co� JUL 2 5 2011 CC: Visa/ MC Last 4 CC # exp date: Auth # TOWN OF VAIL Ol-Jan-11 DS Consulting, Inc. Asbestos Inspection and Sampling Report 227 Bridge Street, Unit F, Vail, Colorado � � � 0 � � Presented To: D Covered Bridge, Inc. .IUL 2 5 ZO�� c/o Dana M.Scheer,Vice-President 50 E.Sample Road TOWN OF VqiL Suite 400 Pompano Beach, FL 33064 Performed&Prepared By: Mr. David Sinkbeil DS Consulting, Inc. PO Box 6864 Avon,CO 81620 (720) 201-6611 Project Details: Project Number: 4369 Conducted: July 9, 2011 PROJECT SUMMARY On July 9, 2011, Mr. David Sinkbeil with DS Consulting, Inc. (DSC) performed a limited asbestos inspection and performed asbestos bulk-sampling at 227 Bridge Street, Unit F,Vail, Colorado, in order to identify potentially hazardous friable and non-friable asbestos-containing materials (ACM) within a portion of the above-referenced, commercial building that has renovation activities being planned. The Colorado Department of Public Health and Environment's (CDPHE) Regulation 8, Part B defines an asbestos-containing material(ACM)as a material containing more than 1%asbestos. Mr. Sinkbeil collected a total of seven (7) asbestos bulk-samples of drywall/texture and ceiling tiles from the following locations within the commercial building: • Drywall/texture-Throughout the Various Walls of Unit • Ceiling Tile-Two types of Ceiling Tiles All seven (7) bulk-samples of drywall/texture and two types of ceiling tiles were analyzed by Aerobiology Laboratory,Inc. (NVLAP#200860-0) in Denver,Colorado with all seven (7) laboratory results reporting as none-detected for asbestos (see Appendix A for laboratory results). 2 PROJECT OVERVIEW I. Introduction A limited asbestos inspection and bulk-sampling for ACM was conducted at 227 Bridge Street,Unit F,Vail, Colorado, by Mr. Sinkbeil on July 9, 2011 at the request of Mr. Dana Scheer, Vice-President of Covered Bridge, Inc. Mr. Sinkbeil is a Colorado State Certified Building Inspector; having EPA Accreditation #13015 (see Appendix B for certificate). The purpose of the inspection was to identify, sample and assess potentially hazardous friable and non-friable ACM throughout the portion of the commercial building that may be impacted by restoration activities. II. Structural Design The structure is a brick-framed, multi-level,commercial building. III. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk-sampling techniques. The asbestos bulk-sampling was conducted on suspect ACM with a limited number of bulk-samples being collected within the commercial unit. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency/AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk-samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Random bulk-samples, representative of the suspect asbestos-containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the following criteria: 1. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics and application. 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if they exhibit similar physical characteristics and the application of the sampled material can be correlated to the application of un-sampled material. Bulk-samples collected were analyzed utilizing the EPA's Method for the Determination of Asbestos in Bulk Building Materials (EPA 600/R/116, July, 1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the bulk-samples was performed on the"date reported,"as listed in the bulk-sample analysis report. 3 [V. Notes on Report Format Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: 1. Surfacing Material: sprayed or troweled onto structural building member. 2. Thermal System Insulation (TSI): any type of pipe,boiler,tank, or duct insulation. 3. Miscellaneous Material: other suspect materials, floor tile, sheet vinyl/linoleum, ceiling tiles, insulation,and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significantly damaged" are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significantly damaged" condition has one or more of the following characteristics: • The surface is crumbling or blistered over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). • One-tenth (one-quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. • Water stains, gouges, or mars are over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. Response-action recommendations for asbestos-containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates the presence of asbestos greater than 1%within the bulk-sample, or a bulk-sample in the same HA, and should be addressed accordingly. A general recommendation indicates asbestos does not exist greater than 1%within the bulk-sample, or all bulk-samples in the same HA, and no further abatement activities are required for removal of the material. Any sample reporting a "TRACE" amount of asbestos must be considered to be positive for asbestos greater than 1%unless it is analyzed by the point-count method to be less than 1%. V. Inspector Comments No asbestos-containing material was identified during the bulk-sampling conducted at 227 Bridge Street, Unit F, Vail, Colorado. A total of five (5) bulk-samples were collected from drywall/texture and two (2) bulk-samples were collected from ceiling tiles. All seven (7) bulk-samples tested none-detected for asbestos. 4 VI. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent-asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The following samples were collected from the single family residence at 227 Bridge Street, Unit F, Vail, Colorado, on July 9, 2011. The quantities are approximations and are subject to field verification. ND = None-detected. � � • . . � . . 1 � � � • - � � - 1 Sample#: DW1-1 Sample#: DW1-2 Sample Description: Drywall/texture Sample Description: Drywall/texture Sample Location: Interior Wall Sample Location: Interior Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: >1000 ftz and <_5000 ftz Material Quantity: >1000 ft2 and <_5000 ft2 Material Condition: Good Material Condition: Good Layers-Asbestos Content.• Layers-Asbestos Content: White compound w/yellow mesh and white White compound w/white paint- ND paint- ND Tan/white drywall-ND Tan white d all- ND Recommendations: EN L-See Section VII Recommendations: GENERAL- See Section VII � � • . . � . . � � � � . . � . . � Sample#: DW1-3 Sample#: DW1-4 Sample Description: Drywall/texture Sample Description: Drywall/texture Sample Location: Interior Wall Sample Location: Interior Wall Material Classification: Surfacing Material Material Classi�cation: Surfacing Material Material Quantity: >1000 ft2 and <_5000 ft2 Material Quantity: >1000 ftz and <_5000 ft2 Material Condition: Good Material Condition: Good Layers-Asbestos Content• Layers-Asbestos Content: White paint w/white compound-ND White compound-ND Tan white d all - ND Tan white dr all- ND Recommendations: GENERAL-See Section VII Recommendations: GENERAL- See Section VII 5 1 / � . . � � . � 1 1 � . . � � . � Sample#: DW1-5 Sample#: CT-1 Sample Description: Drywall/texture Sample Description: Ceiling Tile Sample Location: Interior Wall Sample Gocation: Front Area Ceiling Material Classification: Surfacing Material Material Classification: Miscellaneous Material Material Quantity: >1000 ft2 and <_5000 ftz Material Quantity: <1000 ftz Material Condition: Good Material Condition: Damaged Layers-Asbestos Content: Layers-Asbestos Content: White compound w/white paint- ND White ceiling tile- ND Tan white d all- ND Recommendations: EG NERAL- See Section VII Recommendations: GENERAL- See Section VII � � • . . � . . � Sample#: CT-2 Sample Description: Ceiling Tile Sample Location: Rear Area Ceiling Material Classifrcation: Miscellaneous Material � Material Quantity: <1000 ftz Material Condition: Damaged Layers-Asbestos Content.• White ra ceilin tile- ND Recommendations: GENERAL- See Section VII VII. Recommendations GENERAL: The laboratory results of the potential ACM sampled at 227 Bridge Street, Unit F, Vail, Colorado, indicate that five (5) bulk-samples were collected from drywall/texture and two (2) bulk-samples were collected from ceiling tile and all were reported as none-detected for asbestos. Therefore, no professional abatement activities are recommended to remove the above-referenced material. 6 APPENDIX A LABORATORY ANALYSIS 7 AEROb10I.00�y LAbORATOf2y ASSOGIATES,INCORPORATE� �4 � Client Namc DS Consulting Strcct address 5366 Flatrock Ct City,Statc ZIP Morrison,CO A0465 Attn: David Sinkbcil Client Project Name: 227 Bridgc St.Unit"F" Certificate of Analysis a�dQ�0. NVLAP Lab Codc 200860-0 Tcsc Rcqucsted: 3002,Asbestos in Bulk Samples Method: Polarized Light Microscopy/Dispersion Staining(PLM),Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/1 16,July 1993. 13949 W.Colfax Ave Suite 205 Cakewood,CO 80401 303.2323746 www.aerobioloav.net Date Collected: 07/09/I 1 Date Rcecived: 07/11/I I Datc Analyzed: 07/1 I/I I Date Reportcd: 07/11/11 Project ID: l 1008029 Job ID: Samplc Identification Homo- �Yei Non-Asbestos Non-Fibrous Matrix Physical Description of Sample/Layer gencous Asbestos Detceted Asbcstos Percentage Fiber Material Material Client Iab Sam le Number Y� Percentage Percenta c Percenta e Com osition I 1008029-1A �'�'hite Compound w/Yellow Mesh&White N 8% ND 20 80 C Paint DW1-1 11008029-1B Tan/White Drywall N 92% ND 10 90 G 11008029-2A White Compound w/White Paint N 10% ND 100 C DWl-2 11008029-26 Tan/White Drywall N 90% ND 10 90 G 11008029-3A White Paint w/White Compound N 6% ND 100 C DWl-3 ll008029-3B Tan/White Drywall N 94% ND 10 90 G 11008029-4A White Compound N 50% ND 100 C,G DW1-4 11008029-4B Tan/White Drywall N 50% ND 10 90 G I]008029-SA White Compound w/White Paint N 10% ND 100 C DW1-5 11008029-SB Tan/White Drywall N 90% ND 10 90 G A=Amositc AC=Actinolitc � � l/ AN=Anthophyllitc ����-�--- , ��' iu�'-°�'ja''e'- CHRY=Chrysotilc CR=Crocidolitc TR=Trcmolitc �c ar cgrzyn au nappc Tracc=L.css Than I% Laboratory Analyst Asbcstos Laboratory Supervisor ND=Nonc Dctcctcd Page 1 of 3 13949 W.Colfax Avc.Suitc 205,Lakcwood CO 80401,3032323746 ��w .,•,�..,��r�u�„ _. _. _ _ . _ Q=Quartz P=Pcrlitc C=Carbonatcs B=Bindcr G=Gypsum D=Diatoms M=Mica T=Tar NTR=Non-Asbcstiform TR NAC=Non-Asbcstiform AC .AEriobiotoc;y t�aborz.�aror2y ASSOCIATES, INCORPORATEO � � ClientNamc DSConsulting Strcct address 5366 Flatrock Ct City,Statc ZIP Morrison,CO 8046_5 Attn: David Sinkbcil Client Project Name: 227 Bridgc St Unit"F" Certificate of Analysis a�dQ�� NVLAP Lab Code 200860-0 Tesc Rcqucstcd: 3002,Asbestos in Bulk Samples Method: Polarized Light Microscopy/Dispersion Staining(PLM),Method for the Detemvnation of Asbestos in Bulk Building Materials.EPA-600/R-93/1 16,July 1993. 13949 W.Colfax Avc Suite 205 �keW�a,co soaoi 303.232.3746 www.aerobioloav.net Date Collected: 07/09/11 Date Receivcd: 07/I 1/11 Datc Analyzcd: 07/I I/11 Date Reported: 07/11/11 ProjectlD: 11008029 Job ID: Samplc Idcntification Homo- �y�, Non-Asbcstos Non-Fibrous Matrix Physical Description of Sample/Laycr gcncous Asbestos Detected Asbestos Percentagc Fiber Material Material Clicnt Iab Sam le Numbcr Y� Percentage Pcrcenta e Percenta e Com osition CT-1 11008029-6 White Ceiling Tile N 100% ND 60 40 CT-2 11008029-7 White/Gray Ceiling Tile N 100% ND 60 40 Page 2 of 3 A=Amositc AC=Actinolitc ��� � � // AN=Anthophyllitc a,c /"�"-°(�ja�— CHRY=Chrysotilc CR=Crocidolitc TR=Trcmolitc �c ar cgrzyn au nappc Tracc=LcssThan 1% Laboratory Analyst Asbcstos Iaboratory Supervisor ND=Nonc Dctcctcd 13949 W.Colfax Ava Suitc 205,Lakcwood CO 80401,303.2323746 Q=Quartz P=Pcrlitc C=Carbonatcs B=Bindcr G=Gypsum D=Diatoms M=Mica T=Tar NTR=Nan-Asbcstiform TR NAC=Non-Asbcstiform AC AEROb10�OC.�y LA�]►ORATOR'�/ ASSOGIATES, INCORPORATEO � � Certificate of Analysis 13949 W.Colfax Ave Suite 205 Lakewood,CO 80401 303.232.3746 www.aerobioloqv.net DS Consulting 5366 Flatrock Ct Morrison,CO 80465 David Sinkbeil Client Project Name: 227 Bridge St.Unit"F" a�da�:> NVLAP Lab Code 200860-0 Date Collected: 07/09/11 Date Received: 07/11/11 Date Analyzed: 07/11/11 Date Reported: 07/I 1/11 Project ID: ll 008029 Job ID: General Notes ♦ ND indicates no asbestos was detected;the method detection limit is 1 %. Trace or"<1"indicates asbestos was identified in the sample,but the concentration is less than 1%. ♦ All regulated asbestos minerals(i.e.chrysotile,amosite,crocidolite,anthophyllite,tremolite,and actinolite)were sought in every layer of each sample,but only those asbestos minerals detected are listed.Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunerite. Crocidolite is the common name used for the asbestiform variety of the mineral riebeckite. ♦ Tile,vinyl,foam,plastic,and fine powder samples may contain asbestos fibers of such small diameter(<0.25 microns in diameter)that these fibers cannot be detected by PLM. For such samples,more sensitive analytical methods(e.g.TEM,SEM,and XRD)are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM floor tile analysis is accepted under NESHAP regulations. ♦ These results are submitted pursuant to Aerobiology Laboratory Associates,Inc.'s current terms and conditions of sale,including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted. ♦ Unless notified in writing to return the samples covered by this report,Aerobiology Laboratory Associates,Inc.will store the samples for a minimum period of thirty(30)days before discarding. A shipping and handling charge will be assessed for the return of any samples. ♦ Aerobiology does not guarantee the results of tape lifts,microvacs,wipe,and/or debris samples. Accurate analysis cannot be performed due to particle size,media used,and/or amount of material given. Analysis of these materials should be preformed by a TEM. A result of ND does not indicate that the sample area does not contain asbestos. It means the analyst could not identify asbestos in the specific sample for the reasons listed above. Notes Reauired bv NVLAP ♦ This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST,or any agency of the Federal Govemment. ♦ This test report relates only to the items tested or calibrated. ♦ This report is not valid unless it bears the name of a NVLAP-approved signatory. ♦ Any reproduction of this document must include the entire document in order for the report to be valid. Page 3 of 3 13949 W.Colfax Ave.Suite 205,Lakewood CO 80401,303.232.3746 � APPENDIX B CERTIFICATION 8 � }� - l y y � . ii�' . �t�y�'tA� f r k> >�i�}\�� r .. + �t . .. �i x ,;�.`}� ' :` � Y i'k r .'� i„ r{,,�,yl' i.f�I,�� {,,, 1�«\ x�,��U�f �`.��A� r. ; �y?�� � - � � � yr�,.t 17 .T.>x t ''� s.t f�M. ,� �"!'� ��f ��.� �I1. �� r�}tl.! �"v�i (iiti �iI-.'�.� ,��, l��,%'�n�t.�� .��tic. . �..'� <>� �';r �p. Ty �4.� � 5 f', N � 1. 1� ✓'r � . �x . ,/v 1 ',y� �y �` 4`r` P"�i�� .. Y '�y 1'I } ^ r�'� }� � hM � s wr 1 S)l�t' � lx lV � f�' r � 1� i j ,,� - t ��� �y . 1 �� . C1 ♦ � �1� 14 V i.� ✓ � S �ti f r Y '� � a y 1 1 . �u 1C 1 �'��,�' l�� ��� ���� , I r� ,����v �� � ����;�.+�,. � � r � r F � Y. �� r 7 1� ,/ 1J i F � . r V`,� , , ,.l , .ik �l� S � ��� •Jp � Y �C1` � ^Y�\ �1Y��� M � \V� � • \� ��Y ,y � �� i-4 4' '>Y y � f `�' `,�1�"v S W- 'S"G f'!Y R� ' ��.���. . -`.`�� 1'J;{v��uuv'iJ1� ��iu;�J I�„J�J��Un�JGvi�'�lill�1,•I�G�,JIf+ l�' ., ��„ �i � ,� � .�� � �� ���:, r - , ..,✓:,,..,....,....,,,..,,.r,.,,.,,........J J ������.�J cu-I��;IU fL;�J�u;{�l,u��w�l� ��,,,;Jpv;y,;,�1,� �, `�� z. . �'..v...............................�.:r.`-.'..�.,.'.:.:.:..'....�.,..:....�..'.:..�.::.:....v...r....;c; _.• -,r, i.�j � n-: �- �"'' °� _ � �)) ��c � ��ti , -.; � � . N� ,� • � � , , �� �"w �="� r ,... �a> • � • {c r.i� 1-',.�.' .���� =�)�, �t �:r-, }�� .. � 7) (� s . c 7�) {�� � '„� (;f �� .�)) � Kt , �� : x �j) � u� .r . �ei ((c ����� �x ,�� ♦ � w.� i)� �(c �r ��,r. ` �� ��r� ��� �� � � � ((c �.� +' �•. ti��� ��)) �(C i '���� . � a ?�) ((t '�, � " � ��� ��� � _ ��� -�i� (cc , �,y ,, � �r l�'-;`e � �� � �. . �� i- �. Rs�•- � ' o �t�c:l,'�;;c�� :� ti �:- I ' � ... - � '� �� �i} a � �� <« % � � ^� �� �ij ' �_ � � ^.� e ra !! _ � (�c `�..;,� `_,y �� ij) (c� v .� i„; _� �)) ((c ��iy ; ,li��',� �, i)) (<° , .k �; �t� ' � )) t«_� i�� �.� � _i)) (« I� . _,� ✓`;. r -�)) ((c I.� � ti :, y�� r ��)) (K ���,,.'�)�. � ' r j�� � �' 1 P � �U � w � , -�tz� ' ` e �(c w� { � k;,t\�l � � »� ��� I ���� ,) _�� r /1 n`� �'.- ��j \��:��.-t '.,� c ��- �j} � i ! �� ��� ;; � � ?�) (tc �'�ti� ��� � �"; ''�) ��� '�' ;t'.t�;� . � � i�� �« �t �. �i� �`�alti ;jj� E i � �`'�1 ! � � 1 �! ((� " _z, ���_�)� • � � - �, � � � s _ �(� � ; �i ��� i • �� � ' 3 " 1 � �� �CC � � � ' „' �.�� � s• . ! � � -G �� E� R- ((C ,��, y* tx�� J a .%� a)� ��C-�� �����;i i. ,`�� \ �f�, .))� ��C �,,+�i:- f ; t-.����X I „� �(� ��l`T'y�� '. ,t .__�,, i>) ((t �,�' � J�y r �. 7�� ' � �` ' � � . ` • � f � "� I • ���I ah� �E .)�� ��C �.+.1 .��11-� � � ,i�,l� �-))' ���' n�;,�,.4��`�: .�� 4�� �)� 1 � : '�� 4- �� ��,���� -\ ...j�� • 1 1 � 1 ��L �'x'fs.� � i)) ��� � �;, �r ..j)) 1 1 I � 1 � ((C.�'� ��� ti,, ' i :-f - � �(C_.� i S��.y t '� �i) � / tcc ' r�a���`, �t 1���� ')� . , / r � ({r ' t � �) ./ � ((c =� � � =))� . -� t �-. - - .� �(� t` �� �'� t�L • � `� j � . � � � i)� ((c Y.,_ `_;: '*z�� , ", I Ctt ��� L. --����-�)) (c:- ����' '?�) cc ��:{ 'a, � 1� ��4- ))) (�L . �v� j . 7�i�.�.��.^.i^.�'�.�^�.�.���n v►��.�.�.�.^.::.�.^...�•�"`�n.n.^:�.�. .�.�► .-v�.�'`..^���.^..^�n..��..'�.,�C.,-�� '�'-k � 11/�1��/� /'11�(1 r1i N!H I.r1 I/�,1 � A1 II F � n r/M11 1 N n �1 n I�1/r1 r^1/'1 I'I ^ ln:� 1 !I:1 f f1 In 11 �}�.1.�� " � „ � , r r,r� ., r �r � i r ��,� .�� ^ r��r� ^�^,�:. � �i r �^ n��r r � � ...-r �� � �a� ���-,� o dz.��-. _ � -a.s�r c - �i r ¢ �t�5�''.� ^� � � "'s` .�^z- � ����' ti ,.'`4� 4� ������� "�`x�4 A���f Y A �n 'L-Z �'�,. 1} :�7 �' ,S� x£��t 4� 1 fl's,L�♦ . ,yy�4�y�� , 1 . J, t�s . �, F r . t.:� + �r� �{� t (� ��� 1tt v-y �i r `�i +`?�r� t-�F} �fli , �.��� f j♦ j� j � i`�` �;'�� f 'yq `������'���� f�p�,� � � �� [ �,>�t ti l, i 5. �l f+-F, 1 �� f � �v �ixf 1 x✓ry � .�` �r ;�`« 1, �F,�` h 1� a �� � ���ri\, � � � '4 l �� �S'� .s� )� ...�'' �'�,,, � � .� � t' �( �t � � if.r'1�F r,, �; a''� ;s� ��<< ' '� . i 1 a �J,i �. ��w� "t,� �,�,r1i . � r� t ,.�'�. i j �y� �� .��"� N! � -�i.,f� ��'�` Fr�� � .i t�r ��.i 4t .�.'9r-� � �` r � �Yrr� ;,.<� i.�l �� Yc. l�%'t xtx��' J��� � I� ��.C1r �Y���ti• ' j� ��� "� .fii.r -,h-fy� > "�1�5`hi t i r � � 1 �� � `���'f,�i�x��. ���.x`f. �+ .; �� ,c�, ;�r�! h'� _ ��� ,'_S.'Stv ��?� �� .._�'- :Z" F R C H Design Worldwide TRANSMITTAL 311 Elm Street Suite 600 Cincinnati OH 45202 513 241 3000 fax 513 241 5015 Date: Fri,07/22/11 Project No: 24124.000 Project: Under Armour-Vail To: Development Review Coordinator ❑ Notes ❑ Computer Media ❑ Originals ❑ Proposal Department of Community Development ---���-- ---���------.- --_..... _.__ 75 South Frontage Road ❑ Memo ❑ Shop Drawings � Prints ❑ Contract Vail, CO 81657 --�--.._......----- _._......_....-----.._......_._—._... -.- ----- ❑ Photos � Permit Drawings ❑Samples ❑ Revisions -----..__...--------- -..........---.....--- ❑ Other ❑ Specifications ❑ Construction Drawings Phone: 970-479-2128 ❑Attached ❑ Under separate cover: From: Karl Hoalst Sent Via: UPS Next Day Air Saver For your For your For cor- Revise& Approved Per your Copies Date Description information adion rection resubmit as noted request __......_._...._.__....----------.. _...------................. ---..__......_...........-- --._....--- ------.. ...._._�_._ ._._.__. _._._ _ _ 4 7/22/11 Permit Sets � � _.._......_...........—_...._..._..------._..........------ ._..._.....__.._............. ---..__._........_..-- --._............._..-- --......_..------._...._ .....--._._....._.... __.........._..._ 1 7/22/11 Permit Application � � __....-------.._................---- ..._.......---..._.._...._ _..__..._...................._._. __......_._..............----.. _._...._...._......_.__.._... _ _.....-- --..._._...._.._....-- 1 7/22/11 Plan Review Check � ---._....._..._....__....-----.....__.._..----- ................__...---- --..._........._._..... ._.............._.........--- .........._......_..._.....__ __......_._._..._...-- ---.._._..........-- 1 7/22/11 Asbestos Inspection Report • --................._..... _.._...._._.__........_ .._............—.................._._._.__...................-----..............._._......_...._....._...............---......_..._. ............._..._.................... _.....-------....--- ---.._...........--- ; Enclosed , please find the above listed items related to our application for permit for Under Armour located at 227 Bridge Street. Please let me know if there is anything else you need or if you have any questions. Thanks, Karl Hoalst 513-362-3468 � (� 2 a n� 2 khoalst@frch.com � �� V L� .JUL 2 5 1011 ►��� �� T�wN OF VAIL VS200204 S:�24124.000\01AdminlBuilding Dept Transmittal.doc Page 1 of 1 - �,,...� 10-28-2011 Inspection Request Reporting Page 2 7:36 am _.____�/ai , CO - Cit�[_Q� Requested Inspect Date: Friday, October 28, 2011 Site Address: 227 BRIDGE ST VAIL Covered Bridge Building, Unit F A/P/D Information Activity: 611-0226 Type: COMBO Sub Type: ACOM Status: ISSUED Const Type: Occupancy: Use: M Insp Area: Owner: COVERED BRIDGE INC Contractor: RETAIL CONSTRUCTION SERVICES INC Phone: 651-704-9000 Description: TENANT FINISH: NEW DISPLAY FISTURES, FITTING ROOMS AND SMALL STOCK ROOM Requested Inspection(s) Item: 90 BLDG-Final Requested Time: 01:30 PM Requestor: Phone: Comments: 408-540-8154 Assigned To: JMONDRAGON Entered By: MHAEBERLE K Action: Time Exp: Item: 290 PLMB-Final Requested Time: 03:00 PM Requestor: Phone: C o m m e n ts: 408-540-8154 Assigned To: JMONDRAGON - Entered By: MHAEBERLE K Action: Time Exp: Item: 390 MECH-Final Requested Time: 02:30 PM Requestor: Phone: Com ments: 408-540-8154 Assigned To: JMONDRAGON Entered By: MHAEBERLE K Action: ime Exp: � V � Inspection Historv � Item: 120 ELEC-Rough "Approved** �` 09/20/1T Inspector: sgremmer Action: PI PARTIAL INSPECTION � /�b Comment: wafls only � 09/29/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH-Rough *'Approved *` 09/29/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 224 FIRE-ALARM ROUGH Item: 225 FIRE-SPRINKLER ROUGH Item: 30 BLDG-Framing *"Approved*" 09/20/11 Inspector: JRM Action: PI PARTIAL INSPECTION Comment: APPROVED AREAS THAT DO NOT CONTAIN ELECTRICAL OTHER FRAMING AREA APPROVED 10/05/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 50 BLDG-Insulation Item: 60 BLDG-Sheetrock Nail "*Approved"` 10/07/11 Inspector: JRM Action: PI PARTIAL INSPECTION Comment: PARTIAL ALL EXCEPT FOR ADA AREA 10/07/11 Inspector: JRM Action: AP APPROVED Comment: REPT131 Run Id: 13693