HomeMy WebLinkAboutCook_Ret Wall DesignINC.
CONSULTING STRUCTURAL ENGINEERS
COPYRIGHT 2008 GEBAU, INC. ALL RIGHTS RESERVED1121 Broadway, Ste. 201, Boulder, CO 80302, (303)444-8545
GEBAU DATE:JOB #:
COOK RESIDENCE
5/9/08 08042
RETAINING WALL DESIGN S2.1A
12" @ BASE
16" @ BASE
20" @ BASE
24" @ BASE
1' - TOTAL HT.
2' - TOTAL HT.
3' - TOTAL HT.
4' - TOTAL HT
6" x 12" x 6"
MIN FACE SIZES STONE WT.S (AVG)
30#
8" x 14" x 7"65#
10" x 18" x 9"105#
12" x 22" x 12"250#
TYPICAL DRY STACK
FIELDSTONE RETAINING WALL
18" MAX PLANTABLE
SOIL ON FILTER FABRIC
MIN 36"
12"MIN 12"
15^;
FREE DRAINING GRAVEL OR DRAIN FABRIC PER
SOILS ENGR.
RECOMMENDED STONE LAYUP
SCALE [" = 1'-0
1
S2.1ASTONE RETAINING WALL TABLE
30" @ BASE
36" @ BASE
5'-4 - TOTAL HT.
6'-10 - TOTAL HT
16" x 30" x 16"650#
18" x 36" x 18"1000#
MIN 12"