Loading...
HomeMy WebLinkAboutDATA SHEETPLANNING DATA SHEET Property Address/ Parcel # 1995 Chamonix Lane/ 210312302016  Legal Description Tract 2 Haus Bergkristall - Resubdivision of Lot 27 Buffer Creek  Development Site Area Tract 2 = 8,706sf, Tract 1 = 9,717sf Total = 18,423sf Buildable NA  Planner/ Date Nicole Peterson 01/30/08  Project Description Existing duplex, addition to unit A (Secondary), Tract 2, including additional GRFA on main level above garage and removal of existing loft  Land Use Application(s) # DRB 08-0018 Minor Exterior Alteration  Owner Contact Info John Kirschner 1995 Chamonix Lane, Vail, CO 81657 Ph: 970.476.0550 Other side of duplex: John Garland Neighbor: Janine Erickson 970.476.2571  Primary Contact/ Owner Representative Info Kirk Aker, Aker Architects Box 2762, Edwards, CO 81632 Ph: 970.926.6690 FX: 970.926.6694 kaker@akerarchitects.com  Zoning / SDD # Two-Family Primary/Secondary Residential (PS)  Land Use Designation Medium Density Residential  Date Routed/ DRT Meeting 01/30/08  Environmental Impacts/ Hazards  Hazard Zones Sections 12-12, 12-21, 14-6 & 14-7 Snow Avalanche No   Debris Flow No   Rockfall High Severity Rockfall   Excessive Slopes No   Floodplain No  Wetlands Y/N No  Water Course Setback Section 12-14-7 Required NA Propo sed NA  Fire Prevention Sections 12-11-3C & 14-10-5 Gravel roof  Building Separation Section 14-10-6 NA  Utility Easements/ Equipment (14-10-10) Existing Overhead existing electric Proposed Bury - 14-10-10  Sidewalks/ Trails Existing None Proposed   GRFA (Gross Residential Floor Area) Square Feet Section 12-15  Total Allowed 6,945 -Existing  -Proposed  +Credits   Primary Allowed 4,167 -Existing  -Proposed  +Credits   Secondary Allowed 2,778 -Existing  -Proposed 2,777 (includes change to approved plans – small office addition)  Total Remaining  Primary Total Remaining  Secondary Total Remaining 1 sf  General Zoning District Standards   Setbacks (perimeter) Front 20 Proposed    Side 15 Proposed    Rear 15 Proposed   Minimum Lot Area/ Width Required 15,000 Proposed 18,423  Site Coverage % Allowed 20 % Proposed ~19  Building Height Allowed 33 Proposed 25.5  Landscaping Sections 14-10-8 & 14-10-9 % Required 60 % Proposed 69   Plant size 2” D, 6ft Proposed    Fences NA Propos ed   Retaining Walls Sec. 14-6-7 Height Allowed NA Proposed   Driveway Sections 14-3-1 & 14-3-2 Max Curb-cuts 1 Proposed 1 – reconfigure driveway to be on property – currently on neighbors   Max-Min Slope  Proposed    Max-Min Width  Proposed    Snow Storage % 30 Proposed 30  Parking Sections 12-10 & 14-5 Stalls Required 1.4 Proposed 2 indoor   Loading Req. NA Proposed   Lighting Section 14-10-7 Allowed  Proposed Complies  Waste Management Section 5-9 Wildlife Proof/ Resistant NA Screened   Screening Sections 14-10-9 & 14-10-10 Required NA Proposed   Development Impact Fees / Mitigation Employee Housing NA   Traffic Impact NA   Art In Public Places NA  Notes Conditions of approval: The property is within the High Severity Rockfall Zone therefore, a site specific geological hazard report is required at the time of building permit submittal. Remove existing shed on property prior to final inspection. Bury section of over-head power line that runs from existing home to the nearest post on the west property line. A revocable right-of-way permit is required at the time of building permit. A monitored fire alarm system is required, in compliance with NFPA 72 (2002 edition) and VFES Standards.