Loading...
HomeMy WebLinkAboutDRB080059 data sheet PLANNING CHECK SHEET Property Information  Property Address 4708 East Meadow Drive  Parcel # 210112402001  Legal Description Bighorn Townhouses, Tract A Unit 1  Development Site Area Not on plat – Calculated with GIS the area of the 8 parcels = 33,474 Sq Ft (Eagle County website shows 45,302) I chose to use the GIS number to calculate density 33,474 sf or .77 ac (8du existing/ .77ac = 10.3 units per acre). Since 9 units per acre is the maximum, the GRFA is maxed out, therefore the proposed addition is part of the ‘250’ addition rule.  Zoning / SDD # Low Density Multiple Family (LDMF)  Land Use Designation Medium Density Residential  Known Non-Conformities The development is over the maximum density of 9 units per acre.  Previous Approvals 7/10/1995 approved 48sf of ‘250’ ordinance  Hazard Zones Sections 12-12, 12-21, 14-6 & 14-7 Snow Avalanche Blue Zone (moderate) – back of bldg. no report req.   Debris Flow Moderate Hazard debris flow – back of bldg, no report req.   Rockfall No   Excessive Slopes (Site Disturbance 12-21-14) No   Floodplain No  Wetlands Y/N No  Creeks, Streams Section 12-14-17 No name creek – west of townhome, not on stream setback map, so no setback enforced  Sidewalks/ Trails None  Contact Information  Planner/ Date Nicole Peterson, 3/27/08  Owner Contact Info Larry & Marci Leith – 303.882.6774  Primary Contact/ Owner Representative Info Jo Suther, SRE Construction 376.2233  Project Information  Project Description 200 sf addition (add dining rm/nook on main level and reconfigure upper level to add guest bathroom)  Land Use Application(s) # DRB #08-0059  Proposed Uses (As defined by Zoning) Existing multiple family residential dwelling Permitted, Conditional, Prohibited? Permitted  Date Routed/ DRT Meeting NA  Commercial Floor Area Existing NA Pro posed   Gross Residential Floor Area (Chapter 15)  250 or Interior Conversion? Yes, 250. Development site area not on plat – Calculated with GIS the area of the 8 parcels = 33,474 Sq Ft (Eagle County website shows 45,302) I chose to use the GIS number to calculate density 33,474 sf or .77 ac (8du existing/ .77ac = 10.3 units per acre). Since 9 units per acre is the maximum, the GRFA is maxed out, therefore the proposed addition is part of the ‘250’ addition rule. Previous approval of 48sf addition does not count (prior to 2004) 250 – proposed 179.12sf = 70.88 sf remaining GRFA  Zoning District Standards   Setbacks (perimeter) Projections 14-10-4 Minimum Front 20 Proposed no change   Minimum Side 20 Proposed no change   Minimum Side 20 Proposed No change   Minimum Rear 20 Proposed No change  Lot Area/ Width Minimum NA Proposed   Site Coverage Maximum 11,715.9 (35%) Proposed 5733 existing (GIS) + 108.12 proposed = 5,841.12sf (17.4)  Building Height Maximum 33’ Proposed Not higher than existing  Landscaping Sections 14-10-8 & 14-10-9 Minimum  Proposed    Min. Plant size  Proposed    Fences  Proposed   Retaining Walls Sec. 14-6-7 Max. Height NA Proposed    Min. Setback  Proposed   Driveway Sections 14-3-1 & 14-3-2 Max. Curb-cuts NA Proposed    Max-Min Slope  Proposed    Max-Min Width  Proposed    Heated Y/N  Drive Material    Snow Storage %  Proposed   Parking Sections 12-10 & 14-5 Min. Spaces NA Proposed    Min. Loading  Proposed   Lighting S ection 14-10-7 Allowed NA Proposed   Waste Management Section 5-9 Wildlife Proof/ Resistant NA Screened   Screening Sections 14-10-9 & 14-10-10 Required NA Proposed   Roof Material Sections 12-11-3C & 14-10-5 Complies Y/N   Building Separation Section 14-10-6 Complies Y/N NA  Adopted View Corridors Complies Y/N NA  Utilities (Location, easements) Section 14-10-10   Grading (Less than 2:1) Section 14-6   Development Impact Fees / Mitigation Employee Housing NA   Traffic Impact NA   Art In Public Places NA  Notes - Platted in 1968