Loading...
HomeMy WebLinkAboutB13-0344 PLANS APPROVEDBy David Rhoades at 9:52 am, Sep 19, 2013B13-0344 equipment, etc. furnish by mechanical - refer to both electrical and electrical apparatus as shown on single line diagram and and mechanical drawing for scope and work and additinal infor- Complete connection of HVAC/Plumbing motor(s), water heater(s), Fire alarm system will be by electrical contractor. Complete provision, installation and connection of lighting fixtures, exit signs and lamps as specified and as shown on drawings. Complete branch circuit wiring required for the connection of emergency lighting and exit signs to existing emergency stand Complete feeder(s) installation as required for new and/or devices, new control devices, etc. for a complete lighting and including new panelboards, new conduits, new wires, new wiring Complete wiring system for new lighting and power as shown, contract. Electrical work shall include, but not limited to, these major as indicated on drawing and as specified, as necessary to complete the SCOPE: Furnish all materials and labor required to execute this work 2. 3. 4. 6. 5.Provide grounding and bonding Facilities. Complete all electrical demolition as required. mation. A. ELECTRICAL SPECIFICATIONS 1. drawings. by power system. and power system. b. a. items: A.Contractor shall submit shop drawings for engineer review and approval. MC cable permitted per local codes. Run hard pipe from panel to local Lighting fixtures. Shop drawing submittal shall include: Panelboard(s). CONDUIT AND WIRE: B. 13. A. B. 2. 1. and contractor shall have written approvals from building owner prior Core drilling and patching of existing building structure required for Operating, Maintenance and identification instructions manuals, if electrical work. Core drilling shall follow Building Standard procedures Applicable codes: National Electric Code (2008) PERMITS AND FEES: Obtain and pay for all necessary permits, inspec- tions, examinations and fees or charges necessary for execution and and to the requirements of Federal, State or other City agencies Town of Vail Electrical Code, pertinent NFPA publications Conform to the prevailing edition and amendments thereto of the SHOP DRAWINGS AND SUBMITTAL: to start of any work. Test of entire system and work. REGULATIONS AND CODES: having jurisdiction. completion of electrical work. 12. 11. A. 7. 9. 8. 10. any. N. All cabling shall be bundled and properly secured and terminated. warranty period shall begin at the point of system acceptance or beneficial system during this warranty period at no additional cost to the owner. The free of defects of workmanship or products and will inspect and repair the from the date of project completion. The contractor warrants the system to be O. The warranty set forth for this system shall consist of a full three (3) years use, whichever comes later. Coordinate numbering scheme with owner. enclosed within cable trays, raceways or conduit, as specified. engineer. Cabling shall be in the wall, above the ceiling or where exposed, M. No exposed wiring will be accepted unless approved in writing by the Care must be taken to ensure cables are not kinked, bent beyond limit, including NEC, EIA/TIA 568,569 and 606, and federal, state and local codes. familiar and install in accordance with all applicable codes and standards, L. All cable hangers shall be no more than 48" apart. Contractor shall be Cables are to be kept a minimum of 6" from power lines, electric motors, K. Cable bends shall be no less than eight times the cable diameter or 1.00". termination. No more than .5 inches of exposed untwisted pairs shall be the extent in which each twisted pair is unraveled at the point of its physical J. All connections of twisted wiring shall be made in such a way as to minimize length of the run. Splices and bridge taps with cabling are strictly prohibited. Cabling shall be free from tension at both ends, as well as through out the I. All wiring shall be protected from moving mechanical or physical contacts. cable runs exceeding 90 meters and provide solution to meet the 90 meter H. Route cables so as not to exceed 90 meters in length. Bidder will identify any the case of "hard" drywall ceilings, adequate support shall be accomplished independent hangers. Cable "draped" across ceiling tiles is unacceptable. In G. All cable above the ceiling must be tied and properly supported with F. Provide plenum rated cable when required by article NEC 300-22. overloaded, over-cinched, crushed, improperly untwisted, etc. fluorescent fixtures or heat generating devices. present at these locations. Wiring is to be run in cable tray and conduit where specified. requirement. where reasonably possible. patch panel location, and each wall/floor faceplate that has wiring installed. E. All cables will be labeled with self-laminating labels at each cable end, at each jacks, match faceplates to power, color coded for voice and data, match to modular RJ-45, 8 pin, 8 conductor, Hubbell, Leviton, or lucent or equivalent C. The terminations at the station locations must be Category 6, T568B (AT&T) B. Data cable will be colored blue. Voice cable will be colored white. manufacturers include: Berk-Tek, Belden, Lucent or equivalent. 500 Mhz or better category 6, 4 pair UTP as applicable. Acceptable A. The cabling for voice and data must be continuous, home run, non-spliced, D. Wall mounted patch panels will be provided. cable. Outlets will be securely held in place. B. Cat 6 Wiring Requirements A. General Requirements 14. decora style. Finish per owner or architect. Convenience receptacles will be 20 amp, commercial grade Light switches will be 20 amp, commercial grade,B. ELECTRICAL DEVICES A. decora style. Finish per owner or architect. Provide decora style, finish per owner or architect. Dimming switches will be a minimum of 600w or as noted.C. 15. Support all electrical equipment independent of accessible ceilings as required by NEC. SUPPORT A. All mounting heights will conform to ADA guidelines. Typical receptacleD. heights will be +18"AFF and switch heights will be +46"AFF unless noted otherwise. 16. At fire rated wall space electrical boxes at opposite sides of the wall no less than 24" horizontal distance. ELECTRICAL BOXES A. When phone, TV & power receptacles are shown on plan next to each other. Locate respective receptacles next to each other on site with no more B. than 1" seperating cover plates. Provide GFI type receptacles at kitchens, bathrooms, garages, exterior etc. as required by code. E. H/P HEAT/PHOTOELECTRIC SMOKE DETECTOR ELECTRICAL LEGEND (NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT) RECESSED OR SURFACE DOWNLIGHT WALL MOUNTED LIGHT FIXTURE RECESSED FLUOR. LIGHT FIXTURE SURFACE FLUOR. LIGHT FIXTUREAa Aa FIXTURE DESIGNATIONS: UPPER CASE - FIXTURE TYPE LOWER CASE - SWITCH DESIGNATION SHADING ON FIXTURE INDICATES EMERG. BATTERY BACKUP FLUORESCENT STRIP FIXTURE TRACK LIGHT AS NOTED OR SCHEDULED WALL WASHER POLE-MOUNTED FIXTURE POST (BOLLARD) FIXTURE CEILING OR WALL MOUNTED EXIT LIGHT EMERGENCY BATTERY LIGHTS DUPLEX RECEPTACLE @ 18" UNLESS NOTED DOUBLE DUPLEX RECEPTACLE @ 18" UNLESS NOTED SPECIAL OUTLET AS NOTED FLUSH FLOOR DUPLEX RECEPTACLE DUPLEX RECEPTACLE HALF-SWITCHED @ 18" UNLESS NOTED TELE-POWER POLE JUNCTION BOX IN FLOOR, CEILING OR IN WALL MULTI-OUTLET PLUG STRIP COMPUTER/TELEPHONE OUTLET IN FLOOR OR WALL CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING TELEPHONE BACKBOARD CIRCUIT HOMERUN CONDUIT RUN BELOW FLOOR OR GRADE CONDUIT STUB-UP - CAP & MARK LIGHT SWITCH AT 46" UNLESS NOTED SUBSCRIPTS: 2 = 2-POLE SWITCH 3 = 3-WAY SWITCH 4 = 4-WAY SWITCH K = KEY-OPERATED SWITCH TO = THERMAL OVERLOAD SWITCH P = SWITCH WITH PILOT LIGHT DIMMER SWITCH W/ WATTAGE MAGNETIC MOTOR STARTER DISCONNECT SWITCH TRANSFORMER GROUND PUSHBUTTON CONTROL STATION PHOTOELECTRIC CELL TIME SWITCH THERMOSTAT AT 60" UNLESS NOTED DIVISION 15 EQUIPMENT CIRCUIT BREAKER MOTOR OUTLET AUTOMATIC TRANSFER SWITCH FOOD SERVICE EQUIPMENT PC TS T ABBREVIATIONS - ABOVE COUNTERAC AFF - ABOVE FINISHED FLOOR - ABOVE FINISHED GRADEAFG - ALUMINUMAL - EMERGENCYEM - GROUNDGND - GROUND FAULT INTERRUPTERGFI NIC - NOT IN CONTRACT NL - NIGHT LIGHT NTS - NOT TO SCALE UG - UNDERGROUND WP - WEATHER PROOF XFMR - TRANSFORMER +18"- MOUNTING HEIGHT TO CENTERLINE OF DEVICE AFF OR AFG FIRE ALARM SYSTEM FIRE ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM PULL STATION ALARM HORN OR SPEAKER COMBINATION HORN/STROBE OR SPEAKER/STROBE THERMAL HEAT DETECTORH SMOKE/IONIZATION DETECTORI PHOTOELECTRIC SMOKE DETECTORP DUCT DETECTOR SPRINKLER SYSTEM FLOW SWITCH SPRINKLER SYSTEM TAMPER SWITCH STROBE SMOKE/FIRE DAMPER CONNECTION REMOTE INDICATOR LIGHT COMMUNICATION SYSTEM SPEAKER IN CEILING OR WALL VOLUME CONTROL AT 60" UNLESS NOTED MICROPHONE OUTLET IN FLOOR BOX OR WALL CALL-IN SWITCH PROGRAM BELL INTERCOM CLOCK AMPLIFIER TELEVISION OUTLET CONTACT DOOR SWITCH IN JAMB OR HINGE SECURITY SYSTEM KEY-OPERATED ACCESS SWITCH SURVEILLANCE CAMERA DISTRIBUTION EQUIPMENT SYMBOLS DISCONNECT SWITCH FUSES CIRCUIT BREAKER CURRENT TRANSFORMER TRANSFORMER METER CU - COPPER STEP LIGHT FACP M = MOTION-OPERATED SWITCH POP-UP RECEPTACLE - ELECTRICAL CONTRACTOREC - AUTHORITY HAVING JURISDICTIONAHJ - MECHANICAL CONTRACTORMC - PLUMBING CONTRACTORPC UTP - UNSHIELDED TWISTED PAIR - GENERAL CONTRACTORGC - REFERENCEREF junction box, and run MC cable from junction box to device. 1. WALL ASSEMBLY - THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 HR FIRE RATED ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC WITH NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM) WIDE BY 1-3/8 IN. (35 MM) DEEP CHANNELS SPACED MAX 24 IN. (610 MM) OC. B. GYPSUM BOARD* - NOM 1/2 OR 5/8 IN. (13 OR 16 MM) THICK, 4 FT. (122 CM) WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 26 IN. (660 MM). 2. THROUGH PENETRANT - ONE CONDUIT INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM) (POINT CONTACT) TO MAX 2 IN. (51 MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) STEEL CONDUIT OR NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING 3. FILL,VOID OR CAVITY MATERIAL* - CAULK OR SEALANT - MIN 5/8. 1-1/4,1-7/8 AND 2-1/2 IN. (16, 32, 48 AND 64 MM) THICKNESS OF CAULK FOR 1, 2, 3 AND 4 HR RATED ASSEMBLIES, RESPECTIVELY, APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. MIN 1/4 IN. (6 MM) DIAM BEAD OF CAULK APPLIED TO GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACT LOCATION ON BOTH SIDES OF WALL. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS SHOWN IN THE FOLLOWING TABLE. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS TABULATED TO THE LEFT. 3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT, *BEARING THE UL CLASSIFICATION MARKING PENETRATION THROUGH A FIRE-RATED WALL T 18 " ( 1 ' 6 " ) 46 " ( 3 ' 1 0 " ) 48 " ( 4 ' - 0 " ) 80 " ( 6 ' 8 " ) TYPICAL DEVICE MOUNTING HEIGHTS MAIN CIRCUIT BREAKER & BRANCH CIRCUIT BREAKERS MAXIMUM MOUNTING HEIGHT IS 79", MINIMUM IS 18". THE ELECTRICAL CONTRACTOR WILL PROVIDE A WALK THROUGH WITH THE OWNER/ARCHITECT PRIOR TO FINAL ROUGHIN AS FOLLOWS: x CONFIRM ALL LOCATIONS FOR LIGHT SWITCHES; ADD THREE WAYS IF FOUND NECESSARY. x REVIEW RECEPTACLE LOCATIONS; MOVE AS REQUIRED. PROVIDE UNIT PRICING IF ADDITIONAL RECEPTACLES ARE REQUIRED. x REVIEW RECEPTACLE LOCATIONS AT COUNTERS AND CONFIRM IF THOSE RECEPTACLES SHOULD BE ABOVE COUNTER OR BELOW. MOVE AS REQUIRED. IN GENERAL CONFIRM POWER AND LIGHTING REQUIREMENTS. THE ELECTRICIAN SHOULD BE PREPARED TO REWORK SOME DEVICE LOCATIONS. SIGNIFICANT REWORK SHOULD BE FLAGGED AND UNIT PRICING PROVIDED AND WRITTEN AUTHORIZATION FOR ADDITIONAL COSTS APPROVED PRIOR TO PROCEEDING. +80"AFF P +80:AFF TELEPHONE ONE- LINE DIAGRAM TELEPHONE/ COMPUTER ROUGHIN CONDUCTOR SIZES AND TYPES: For sizes #1/0 AWG and larger, use coppper THW or aluminum XHHW. For sizes #1 AWG and smaller, use only copper wire with 600V insulation, types TW, THHN, or THW - stranded in sizes #8 and larger, solid in sizes #10 and smaller. Control wiring shall be #14, stranded. Use type THHN for wires entering or passing through fluorescent lighting fixtures. All motors shall be wired with copper conductors only. UNO - UNLESS NOTED OTHERWISE 2"C PVC WITH PULLWIRE BURIED 20" BELOW GRADE CATV PEDESTAL COAX RECEPTACLE IN SINGLE GANG BOX @ 18" A.F.F. UNO QUANTITIES PER FLOOR PLANS (RG6 QUAD SHIELDED CABLE) 3/4"C CONDUIT STUBBED TO ACCESSIBLE CEILING, PLENUM RATED WIRE, WHEN REQUIRED, RAN TO BACK BOARD STRUCTURED CABLE DISTRIBUTION PANEL #6 CU G METALLIC COLDWATER PIPE ROUTE WIRE AT CEILING PARALLEL OR PERPENDICULAR TO STRUCTURE. SECURE TO STRUCTURE AT 4' INTERVALS OR LESS. STUB UP TO ABOVE ACCESSIBLE CEILNG STRUCTURED CABLE DISTRIBUTION PANEL (2#CAT 6) 3/4"C PLENUM RATED WIRE WHEN REQUIRED (1) RJ-11 & (1) RJ-45 IN SINGLE GANG BOX AT 18" AFF UNO COLD WATER PIPE NOT TO SCALE NOTES: 1.HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE. 2.DEVICES ABOVE DOORS SHALL BE CENTERED BETWEEN TOP OF DOOR TRIM AND CEILING LINE. 3.MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS AND NOTED ON ELECTRICAL FLOOR PLANS SHALL GOVERN OVER THOSE SHOWN ABOVE. 4.FOR CEILING HEIGHTS HIGHER THAN 7'2", INSTALL FIRE ALARM NOTIFICATION AUDIO AND VISUAL APPLIANCES AT 80"AFF OTHERWISE INSTALL AT 6" BELOW CEILING. 5.MOUNTING HEIGHTS PER IBC 2009 AND ADA CODES MAIN TELE/DATA ROOM (PULLWIRE)4"C NOT TO SCALE NO SCALE NO SCALE FINISHED FLOOR TYPICAL 8'0" CEILING Provide tamper proof receptacles at all residential areas as required by code. F. of ww w . a e c - v a i l . c o m C Me c h a n i c a l , E l e c t r i c a l & L i g h t i n g D e s i g n S e r v i c e s Ar c h i t e c t u r a l E n g i n e e r i n g C o n s u l t a n t s Te l e p h o n e : 9 7 0 - 7 4 8 - 8 5 2 0 F a x : 9 7 0 - 7 4 8 - 8 5 2 1 EG Drawn By:Checked By: DATE:ISSUE: 08-09-13 PROGRESS AEC PROJECT #: EX P A N S I O N 29 1 B R I D G E S T R E E T VA I L , C O 8 1 6 5 7 13062 $Q  2 I I L F H  Z L W K  / ( ( ' Œ  $ F F U H G L W H G  3 U R I H V V L R Q D O V 08-19-13 PERMIT .+'51* '.'%64+%#. .')'0& 52'%5 &'6#+.5 5%#.'010' '  T PP PANEL 100/2 BAR PANEL VP1 PANEL VP2 PANEL EXISTING WIRE UTILITY TRANSFORMER EXISTING MAIN DISTRIBUTION CENTER "MDC" 800A, 120/208V, 3P, 4W 42kAlC NO SCALE NOTE: PROVIDE SHORT CIRCUIT BRACING TO MEET REQUIREMENTS NOTED AT ONE-LINE, NOTED AS "AIC AVAILABLE". SERIES RATED COMBINATION ACCEPTABLE, SUBMIT MANUFACTURER'S SERIES RATINGS WITH SHOP DRAWING REVIEW. NO SCALE NOTE: PROVIDE #3/0 CU CONDUCTORS TO ALL GROUNDING ELECTRODES. N G INCOMING WATER SERVICE PIPE (3) 3/4"x10' DRIVEN GROUND RODS IF REQUIRED BY LOCAL AHJ BONDING JUMPER (#3/0 CU G)3/4"C #6 TO TELEPHONE/TV CONCRETE- ENCASED ELECTRODE WATER METER BUILDING STEEL INCOMING GAS SERVICE PIPE R1 PANEL REWORK CIRCUIT AND PANEL TO NEW LOCATION. OTHER EXISTING BLDG METER LOADS 100/2 400/3 100/2 CIRCUIT AND PANEL EXISTING TO REMAIN CIRCUIT AND PANEL EXISTING TO REMAIN CIRCUIT AND PANEL EXISTING TO REMAIN of ww w . a e c - v a i l . c o m C Me c h a n i c a l , E l e c t r i c a l & L i g h t i n g D e s i g n S e r v i c e s Ar c h i t e c t u r a l E n g i n e e r i n g C o n s u l t a n t s Te l e p h o n e : 9 7 0 - 7 4 8 - 8 5 2 0 F a x : 9 7 0 - 7 4 8 - 8 5 2 1 EG Drawn By:Checked By: DATE:ISSUE: 08-09-13 PROGRESS AEC PROJECT #: EX P A N S I O N 29 1 B R I D G E S T R E E T VA I L , C O 8 1 6 5 7 13062 $Q  2 I I L F H  Z L W K  / ( ( ' Œ  $ F F U H G L W H G  3 U R I H V V L R Q D O V 08-19-13 PERMIT .+'51* '.'%64+%#. 10'Ä.+0' 2#0'. 5%*'&7.'5 5%#.'010' '  SHEET DETAIL NOTES: LOCATION OF EXISTING PANEL PP IN EXISTING TOY SHOP. REWORK AND MOVE TO NEW PANEL PP LOCATION IN MECHANICAL ROOM. 2' PLUG MOLD WITH 2 OUTLETS PER FOOT AND GFI PROTECTION. NO CIRCUITS ADDED TO THIS PANEL. KEEP EXISTING CIRCUITS INTACT. EF-1 LOCATED ON ROOF. CIRCUIT EF-2 TO SWITCHED LIGHTING CIRCUIT IN BATHROOM 1 PANEL-PP PANEL-BAR [E] 1 AC-GFI REFRIG-GFI CEILING CEILING CEILING TV RECPT REFRIG-GFI TV RECPT TV RECPT TV RECPT 2 2 2 PP-1 PP-5 PP-7 PP-4 PP-6 PP-12 PP-8 PP-11 PP-2 PP-9 PP-10 3 3 TO KH 1 MAU 1 EF 1 PP-12 4 4 PP-15 PP-19 EF 2TO 5 5 PP-21 P 1 TO PP-18 PP-20 2 of ww w . a e c - v a i l . c o m C Me c h a n i c a l , E l e c t r i c a l & L i g h t i n g D e s i g n S e r v i c e s Ar c h i t e c t u r a l E n g i n e e r i n g C o n s u l t a n t s Te l e p h o n e : 9 7 0 - 7 4 8 - 8 5 2 0 F a x : 9 7 0 - 7 4 8 - 8 5 2 1 EG Drawn By:Checked By: DATE:ISSUE: 08-09-13 PROGRESS AEC PROJECT #: EX P A N S I O N 29 1 B R I D G E S T R E E T VA I L , C O 8 1 6 5 7 13062 $Q  2 I I L F H  Z L W K  / ( ( ' Œ  $ F F U H G L W H G  3 U R I H V V L R Q D O V 08-19-13 PERMIT .+'51* (+456 (.114 219'4 2.#0 5%#.'žÄ '  NORTH FIRST FLOOR POWER & SYSTEMS PLAN SCALE: 1/4" = 1'0" A A A A A A A A A A A A A A A A A A A A A B B B B B B B AA C D D D D C D D D D C D D D D A A A AAA A A F F G PP-14 SHEET DETAIL NOTES: LOCATION OF EXISTING PANEL PP IN EXISTING TOY SHOP. REWORK AND MOVE TO NEW PANEL PP LOCATION IN MECHANICAL ROOM. 2' PLUG MOLD WITH 2 OUTLETS PER FOOT AND GFI PROTECTION. NO CIRCUITS ADDED TO THIS PANEL. KEEP EXISTING CIRCUITS INTACT. EF-1 LOCATED ON ROOF. 1 2 3 4 GENERAL NOTES: 1.PROVIDE COMPATIBLE DIMMER FOR EACH LIGHT TYPE. 2.MATCH EXIT SIGNS AND EGRESS LIGHTS TO EXISTING. PP-16 (E) (E) (E) (E) of ww w . a e c - v a i l . c o m C Me c h a n i c a l , E l e c t r i c a l & L i g h t i n g D e s i g n S e r v i c e s Ar c h i t e c t u r a l E n g i n e e r i n g C o n s u l t a n t s Te l e p h o n e : 9 7 0 - 7 4 8 - 8 5 2 0 F a x : 9 7 0 - 7 4 8 - 8 5 2 1 EG Drawn By:Checked By: DATE:ISSUE: 08-09-13 PROGRESS AEC PROJECT #: EX P A N S I O N 29 1 B R I D G E S T R E E T VA I L , C O 8 1 6 5 7 13062 $Q  2 I I L F H  Z L W K  / ( ( ' Œ  $ F F U H G L W H G  3 U R I H V V L R Q D O V 08-19-13 PERMIT .+'51* (+456 (.114 .+)*6+0) 2.#0 5%#.'žÄ '  NORTH FIRST FLOOR LIGHTING PLAN SCALE: 1/4" = 1'0" TO T A L CF M O. A . C F M H P E S P ( I N ) R P M IN P U T (M B H ) OU T P U T (M B H ) ME D I A S I Z E EF F . CO O L . FA C E V E L . (F T / S ) PD ( P S I ) L ( I N ) H ( I N ) W ( I N ) MA U - 1 R E Z N O R S D H 7 5 K I T C H E N H O O D ME C H A N I C A L RO O M 1, 0 5 0 1 , 0 5 0 1 1 . 0 - 7 5 4 0 - - - - - 5 6 - 5 / 8 3 4 - 1 / 2 3 2 - 5 / 8 4 0 0 EXISTING EQUIPMENT. VERIFY DATA PRIOR TO INSTALLATION. MAX AIR FLOW AT SEA LEVEL 1406 CFM, REBALANCE TO ACFM AS SHOWN IN THIS SCHEDULE. IN - D I R E C T G A S F I R E D M A K E - U P A I R U N I T S C H E D U L E OR EQUIVALENT EL E C T R I C A L D A T A D I M E N S I O N S V / P H / H z 12 0 / 1 / 6 0 SE R V I C E L O C A T I O N OPER. WT. (LBS)REMARKS UN I T TA G MA N U F A C T U R E R & MO D E L N O . BL O W E R D A T A H E A T I N G C A P A C I T Y E V A P O R A T I V E C O O L I N G C A P A C I T Y WI D T H L E N T H C F M S . P . W I D T H L E N T H C F M S . P . L H W KH - 1 CA P T I V E A I R E 72 2 4 - N D - 2 KI T C H E N EQ U I P M E N T SE E F L O O R P L A N I 4 5 0 1 , 2 8 3 1 , 8 0 0 1 0 1 2 1 , 2 8 3 0 . 6 5 2 - - - - - - 9 0 2 4 7 2 430 STAINLESS STEEL WHERE EXPOSED461DUCT TEMP. SENSOR 1 PER RISER, FACTORY INSTALLED, FIELD WIRED TO CONTROL PANEL. REMOTE CONTROL BOX. DI M E N S I O N S ( I N C H E S ) LO C A T I O N UN I T TA G MA N U F A C T U R E R & MO D E L N O . SU P P L Y P L E N U M TY P E MA X . HO O D TE M P TO T A L CF M VE L O C I T Y (F P M ) EX H A U S T P L E N U M KI T C H E N E X H A U S T H O O D S C H E D U L E OR EQUIVALENT SE R V I C E TO T A L CF M REMARKSOPER WT. (LBS) RI S E R D I M E N S I O N S ( I N C H E S ) HOOD CONSTRUCTION VE L O C I T Y (F P M ) RI S E R D I M E N S I O N S ( I N C H E S ) POWER EF - 1 CA P T I V E A I R E NC A 1 4 H P F A KI T C H E N H O O D TO P O F T H E SH A F T UP B L A S T 1 2 8 3 1 4 1 8 1 3 / 4 H P 1 3 8 4 8 I N T E R L O C K W I T H K I T C H E N H O O D C O N T R O L A N D M A U C O N T R O L EF - 2 PA N A S O N I C FV - 1 1 V Q 2 UN I S E X A D A RE S T R O O M UN I S E X A D A RE S T R O O M CE I L I N G 9 0 1 , 1 6 1 0 . 2 5 2 0 . 7 W 0 . 5 1 0 . 4 I N T E G R A L B A C K D R A F T D A M P E R , I N T E R L O C K W I T H W A L L S W I T C H EF - 3 E N E R V E X I P V B 3 0 0 MA U P O W E R VE N T SE E F L O R R P L A N I N L I N E 5 0 V A R I E S V A R I E S 0 . 3 5 K W N / A 7 5 IF ONLY EXHAUST FAN IS INSTALLED PROVIDE EBC12 MODULATING DRAFT CONTROLLER, IF SUPPLY FAN IS INSTALLED, PROVIDE EBC30 CONTROLLER.NOISE LEVEL (SONES)120 / 1 / 60OPER. WT. (LBS) TY P E EX H A U S T F A N S C H E D U L E OR EQUIVALENT UN I T TA G MA N U F A C T U R E R & MO D E L N O . REMARKS SE R V I C E TO T A L CF M FA N RP M ES P ( I N ) ELECTRICAL DATA V / PH / Hz LO C A T I O N 208 / 1 / 60 120 / 1 / 60 UN I T TA G MA N U F A C T U R E R & MO D E L N O . SE R V I C E L O C A T I O N C F M S I Z E ( W " x H " ) FA C E VE L O C I T Y (F P M ) PRESSURE DROP (IN SP)FREE AREA (ft²)FRAME TYPEFINISHREMARKS L- 1 R U S K I N - E L F 6 3 7 5 D X M A U O . A . SE E F L O O R PL A N S 1, 0 5 0 2 4 x 2 4 5 5 5 0 . 0 5 1 . 8 9 COORD. W/ARCHCOORD. W/ARCH- LO U V E R S C H E D U L E OR EQUIVALENT OR EQUIVALENT UN I T TA G MA N U F A C T U R E R & MO D E L N O . US E MO U N T I N G LO C A T I O N ST Y L E FR A M E TY P E FINISHMAX SOUND LVL (NC)REMARKS A T I T U S - 3 0 0 R L S U P P L Y S E E F L O O R P L A N 22 ° L O U V E R E D DO U B L E D E F L E C T I O N SU R F A C E MO U N T COORD. W/ ARCH25STEEL CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS, SIZES, AND SPECIFIED CFMS. AI R D E V I C E S C H E D U L E OR EQUIVALENT CA P A C I T Y (M B H ) GP M E W T ( ° F ) L W T ( ° F ) P D ( F T ) H P L ( I N ) H ( I N ) D ( I N ) UH - 1 DA I K I N M c Q U A Y 5W B 0 9 0 2 B ME C H A N I C A L RO O M 10 5 0 3 0 8 0 0 3 . 2 1 8 0 1 5 9 0 . 1 - 3 4 . 7 6 1 5 - 4 1 CONNECT WITH MAU CONTROL, INTERLOCK WITH DISCHARGE AIR TEMPERATURE HY D R O N I C U N I T H E A T E R S C H E D U L E MA N U F A C T U R E R & M O D E L N O . LO C A T I O N OPER. WT. (LBS) HE A T I N G C O I L D A T A REMARKS UN I T TA G -DIMENSIONSELECTRICAL DATA CF M V / PH / Hz OR EQUIVALENT V / PH / HzHP\W P- 1 GR U D F O S UP S 1 5 - 5 5 S F C UH - 1 M E C H A N I C A L R O O M I N L I N E 3 . 2 5 . 0 1 1 5 / 1 / 6 0 8 7 W TOTAL HEAD (FT)ELECTRICAL DATA UN I T TA G MA N U F A C T U R E R & MO D E L N O . REMARKS SE R V I C E L O C A T I O N T Y P E G P M PU M P S C H E D U L E JO B N A M E : P R O J E C T E L E V A T I O N : 8 1 5 0 A . S . L . JO B N U M B E R : G A S V A L U E : 8 0 8 B T U / C F DA T E : G A S C O M P A N Y : PR E P A R E D B Y : M A X . P I P E R U N : 5 0 L . P . 0M.P. TA G D E S C R I P T I O N B T U H T A B L E C F H S I Z E PI Z Z A PI Z Z A O V E N 24 0 , 0 0 0 . 0 0 29 7 . 0 1 " 24 0 , 0 0 0 29 7 . 0 3 1 - 1 / 4 " MA I N - T O T A L GA S S I Z I N G S C H E D U L E 13 0 6 2 8/ 1 9 / 2 0 1 3 MA R T I N Z O U R E K LOCAL VE N D E T T A S R E S T A U R A N T TA G M A N U C T U R E R & M O D E L N O D E S C R I P T I O N W A S T E V E N T CO L D WA T E R HO T WA T E R REMARKS LV - 1 LA V A T O R Y 1 - 1 / 2 " 1 - 1 / 2 " 1 / 2 " 1 / 2 " P - T R A P WC - 1 WA T E R C L O S E T 3 " 2 " 1 / 2 " - F L U S H T A N K P R I V A T E / P U B L I C W A T E R C L O S E T GW - 1 GL A S S W A S H E R I . W . - - 3 / 4 " R E F E R E N C E M A N U F A C T U R E R ' S M A N U A L F O R C O N N E C T I O N , C O N N E C T V I A A I R G A P T O F S - 1 HS - 1 HA N D S I N K 1 - 1 / 2 " 1 - 1 / 2 " 1 / 2 " 1 / 2 " P - T R A P P- 1 IC E B I N I . W . - - - C O N N E C T T O F S - 1 V I A A I R G A P P- 2 DR A I N B O A R D I . W . - - - C O N N E C T T O F S - 1 V I A A I R G A P P- 3 BE A R T A P D R A I N I . W . - - - C O N N E C T T O F S - 1 V I A A I R G A P P- 4 WA T E R D I S P E N S E R 1 - 1 / 2 " 1 - 1 / 2 " 1 / 2 " - P - T R A P FD - 1 Z U R N Z 4 1 5 B F L O O R D R A I N 2 " 1 - 1 / 2 " - - P R O V I D E P R O S E T T R A P G U A R D I N C O M M E R C I A L A R E A S WC O Z U R N Z 1 4 4 6 W A L L C L E A N O U T V A R I E S - - - P.C. TO PROVIDE CLEANOUTS AT EACH CHANGE OF DIRECTION OF THE HORIZONTAL WASTE LINES GREATER THAN 45° WITHIN 40 FT OF DEVELOPED LENGTH OF THE DRAINAGE PIPING. VERIFY EXACT LOCATION OF CLEANOUTS IN FIELD. PL U M B I N G F I X T U R E C O N N E C T I O N S C H E D U L E PL U M B I N G F I X T U R E S P E C I F I C A T I O N S & H A R D W A R E S E L E C T I O N TO B E B Y T H E I N T E R I O R D E S I G N E R . F I X T U R E A L L O W A N C E NO T T O E X C E E D T H E E S T A B L I S H E D B U D G E T . 20 1 2 I P C W a t e r S e r v i c e S i z i n g VE N D E T T A S 13 0 6 2 Ma r t i n Z o u r e k In d i v i d u a l F i x t u r e Co l d H o t T o t a l C o l d H o t T o t a l Dis h w a s h e r , c o m m e r c i a l 1 0 . 0 2 . 8 2 . 8 0 . 0 0 0 . 0 0 2 . 8 0 2 . 0 2 La v a t o r y p u b l i c & h a n d s i n k s 4 1 . 5 1 . 5 2 . 0 6 . 0 0 6 . 0 0 8 . 0 0 1 . 0 4 Wa t e r C l o s e t , 1 . 6 G P F G r a v i t y T a n k p r i v a t e 1 2 . 0 2 . 0 2 . 0 0 2 . 0 0 3 . 0 3 Co l d H o t E n t r y D r a i n a g e Wa t e r S u p p l y / D r a i n F i x t u r e U n i t T o t a l 6 8. 0 6 . 0 0 1 2 . 8 0 9 . 0 13 1 1 1 6 . 5 1- 1 / 4 " 1 - 1 / 4 " 1 - 1 / 2 " 4 " Ve l o c i t y - F P S 2 . 7 0 2 . 5 0 2 . 6 0 Pip e S i z e RE S U L T : E X I S T I N G W A T E R S U P P L Y I S S U F F I C I E N T T O S E R V E A D D E D F . U . Fix t u r e U n i t s Fi x t u r e U n i t s De m a n d Fi x t u r e Un i t s Total Fixture Units DO M E S T I C W A T E R S I Z I N G C H A R T Fl o w - G P M De m a n d Fi x t u r e Qu a n t i t y Wa t e r S u p p l y Fi x t u r e U n i t s To t a l Fi x t u r e U n i t s Dr a i n a g e S u p p l y Fi x t u r e U n i t s JOB NAME:JOB NUMBER:DATE:PREPARED BY:I.Water Usage =KS-1Length= Width=Depth=0.00 Water Usage =Length= Width=Depth=0.00 Length= Width=Depth=0.00 0.00 Water Usage =PS-1Length= Width=Depth=0.00 Length= Width=Depth=0.00 Length= Width=Depth=0.00 Length= Width=Depth=0.00 Length= Width=Depth=0.00 0.00 1. Measure dimensions, in inches, of the sink.Water Usage=Length= Width=Depth=0 Water Usage (GPH)Number of fixturesMax. hrly water usge per type of fixture 55.000.000.00 23.001.0023.00 30.000.000.00 32.000.000.00 5.004.0020.00 7.000.000.00 35.000.000.00 14.000.000.00 35.000.000.00 43.00 II.Elevation= 66871.26748 1.26748x43.00=54.50 III.Min. MBH=60.53Min. Kw= 13.31 EXISTING INSTALLED WATER HEATERS (2) SMART 120 HAVE SUFFICIENT CAPACITY TO SERVE ADDED F.U.Calculate Total Water Required By All Fixtures:B. Four compartment sink calculation of water usage:Calculate the Minimum BTU of Kilowatt rating of Water Heater:A. Gas Water Heater Adjustment factor =*If all 3 sinks are same *If sinks are different hose bibb used for cleaningA. Three compartment sink calculation of water usage:hand operated pre-rinse sprayerCommercial Hot Water Sizing −Appendix D of Colorado Retail Food Establishment Rules & Regulations 13062VENDETTAS 8/19/2013 *If all 4 sinks are same adjustment factortotal water required by all fixturesC. Utensil soak sink:Calculate Maximum Hourly Hot Water Usage:handsink(s), include rest roomsPlumbing Fixture warewashing machine Total water (gph) required by all fixturesshowersmop sink garbage can washerglass-warewashing machine pot fillerD. Misc. Plumbing Fixtures max hrly hot water usage