Loading...
HomeMy WebLinkAboutB13-0437 PLANS.pdf B13-0437 ACTIVE E NERC IES SOLAR.LLC Grid-Tied with Battery Backup Photovoltaic System Details System Layout Panels (16 SunPower X-21 335 BLK 335 watt) nGr Inverter (SunPower SPR 500op-TL-1-240) Critical Main Panel Load Panel Off Grid Solar Energy AC Management Devices Disconnect (3 Outback Radian GS8048) Generator Batteries By others (16 Full River DC400-6 6v 400AH) Operation Modes Grid Connected Normal Operation: Grid feeds the Main Panel(s). PV(photovoltaic) and/or Grid feed the Critical Load Panel. Batteries are charged by solar and/or the grid. Batteries Low: Grid feeds the Main Panel(s). Power from the Grid will feed the Critical Load Panels and charge the Batteries. Batteries are Restored by Grid or Solar: Grid feeds the Main Panel(s). Return to "Grid Connected" normal operation - PV and/or Grid feed Critical Load Panels. RECEIVED By David Rhoades at 8:50 am, Oct 02, 2013 Page 1 of 8 10/1/2013 P.O.Box 7627,Awn,CO 81620 1 P: 970.227.0272 1303.330.4880 1 F: 866.403.3485 1 www.activeenergies.com Ac'�1.1'\-E ENI-ORGIES Excess Solar Power: Critical Load Panels are fully served by PV and the Batteries are fully charged. Excess PV power will feed the Main Panel(s). If all loads on Main Panel(s) are served, excess power will go out the grid. Grid Outage Normal Operation: Main Panel(s) are out of power. PV and Batteries feed Critical Load Panel until the grid returns or the batteries are too low to maintain the critical loads. Batteries Low: Main Panel(s) are out of power. PV and Batteries feed Critical Load Panels until the grid returns or the batteries need to be charged by the generator. Generator feeds the critical loads panel and PV is shut down. Batteries are Restored by Generator: Main Panel(s) are out of power. Generator is turned off and return to "Grid Outage" normal operation. Excess Solar Power: Main Panel(s) are out of power. PV charges the batteries and feeds the Critical Loads Panels. Critical Load Panel is fully served by PV and Batteries are fully charged, Outback Radians will shutdown PV via relay. Page 2 of 8 10/1/2013 P.O.Box 7627,Awn,CO 81620 1 P: 970.227.0272 1303.330.4880 1 F: 866.403.3485 1 www.activeenergies.com ACTIVE ENERGIES SOLAR. Solar Installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-3 76-3 720/3 03-3 3 0-48 80/info @activeenergies.com) Site: Marshall Residence 193 Beaver Dam Road Vail, CO 81657 All AC wiring to be completed by a Colorado licensed master electrician Panel Arrangement: 1 row if 16 panels on the upper south facing roof F F F F F F 4 4 F - I I I I I I I I I I I I I I I I I I I I I I I I I I I I SunPower Inverter and Outback Radians to be mounted in rec room closet and batteries to be mounted in bedroom 2,new closet. PV AC disconnect and Critical Loads Panel disconnect located on the outside of the building. Minimum Designed Temperature: -40°F Average High Ambient Design Temperature: 121°F Page 3 of 8 10/1/2013 P.O.Box 7627,Awn,CO 81620 1 P: 970.227.02721303.330.4880 1 F: 866.403.3485 1 www.activeenergies.com VCTIVE ]ACA NERGIES Calculations SOLAR... 5.36kW System Size (STC) 16 SunPower X-21 335 BLK black solar panels @ 335watts 1 SunPower SPR 5000p-TL-1-240 inverter- 3 strings of 5/5/6 modules 3 Outback Radian GS8048 Off-Grid Solar Energy Management Devices 16 Full River DC400-6 6v 400AH batteries Fixed array tilt angle: 45° Array azimuth: 185°(where 180° is magnetic south) Estimated Production: 7,805 kWh/yr(not including shading) Maximum PV System Voltage: 690.7 Von= 67.9V/module 67.9V x 6 modules =407.4V Temperature correction factor Table 690.7(A) Temperature Coefficient (Voc) = -167.4mV/°C (25°C - -40°K) = 65°C (-65°C x (-167.4mV/°C) x 6 module) + 407.4V 472.7V Temperature correction factor Table 690.7 For-40°F use 1.25 407.4V x 1.25 509.3V Maximum PV Source Circuit (String) Current: 690.8 (A)(1) Is, =6.23A 6.23A x 1.25 = 7.8A Maximum PV Output Circuit (Array) Current (per inverter): 690.8 (A)(2) 7.8A x 3 strings =23AA Inverter Output Circuit Current: 690.8 (A)(3) 23A @ 240V Stand-Alone Inverter Input Circuit Current 690.8 (A)(4) 5000W_41Vdc- 95% = 128A Page 4 of 8 10/1/2013 P.O.Box 7627,Awn,CO 81620 1 P: 970.227.02721303.330.4880 1 F: 866.403.3485 1 www.activeenergies.com ACTIVE ENERGIES Conductor Sizing SOLAR... Panels to DC Disconnect/SunPower Inverter (per string): 7.8A x 125%= 9.8A 690.8 (13)(1) #10 USE-2 Table 310.16 40A (90°C column, see note 240.4(D)) Conduit fill adjustment Table 310.15 (13)(2)(a) For 4-6 Current Carrying Conductors use .8 9.8A= .8 = 123A Temperature correction factor Table 310.16 40A x .58 =23.2A SunPower Inverter to Critical Service Panel: 23A @ 240V 23A x 125% =28.8A 690.8 (13)(1) #10 THWN-2 Table 310.16 30A (75°C column) Conduit fill adjustment Table 310.15 (13)(2)(a) No conduit fill adjustment Temperature correction factor Table 310.16 No temperature correction factor 30A Overcurrent Protection Device Critical Service Panel to AC Disconnect/Bypass Switch/Outback Combining Panel: Outback Radian Output Power 8,000Watts AC 8,000 W-240V= 33.3A 33.3A x 125%=41.6A 690.8 (13)(1) 41.6A x 3 inverters = 124.8A 1/0 THWN-2 Table 310.16 150A (90°C column) No Conduit fill adjustment Table 310.15 (13)(2)(a) No temperature correction factor 50A Overcurrent Protection Device per Outback Radian specifications 150A Overcurrent Protection Device on Outback Combining Panel Page 5 of 8 10/1/2013 P.O.Box 7627,Awn,CO 81620 1 P: 970.227.02721303.330.4880 1 F: 866.403.3485 1 www.activeenergies.com ACTIVE ENERGIES SOLAR. Main Service Panel to Bypass Switch/AC Disconnect: 1/0 THWN-2 Table 310.16 150A (90°C column) No Conduit fill adjustment Table 310.15 (13)(2)(a) No temperature correction factor 150A Overcurrent Protection Device in Main Service Panel Main Service Panel to Outback Radians: Maximum Input Power per inverter 50A AC (per manufacturer) #6 THWN-2 Table 310.16 55A (75°C column) No Conduit fill adjustment Table 310.15 (13)(2)(a) No temperature correction factor 50A Overcurrent Protection Device per Outback Radian specifications Battery Bank to Outback Radian: Continuous Battery Charge Output I I 5 AC (per manufacturer) 8000W-41 Vdc- 90% = 128A 690.8 (A)(4) 128A x 125% = 160A 690.8 (13)(1) 2/0 RHW-2 Battery Cables Table 310.16 175A (75°C column) 175A Overcurrent Protection Device No conduit fill adjustment No temperature correction factor Conductors may be oversized for voltage drop Page 6 of 8 10/1/2013 P.O.Box 7627,Awn,CO 81620 1 P: 970.227.02721303.330.4880 1 F: 866.403.3485 1 www.activeenergies.com ACTIVE ENERGIES PV System Specifics SOLAR.. 16 SunPower X-21335wattBLKpanels Line Diagram Voc:67.9V Marshall Residence Array mounted on ground Isc:6.23A 193 Beaver Dam Road 6#10 USE-2/RHW-2 1#6G Bare Cu Array on roof Operating Voltage:343.8V Vail,CO 81657 Conductors in Free Air Operating Current:17.55A Max System Voltage:472.7V Tilt Angle:45° Max Output Current:23.4A Array Azimuth:185° Voc Temperature Coefficient:-167.4mV/°C Production:7,281 kWh/yr 5 Modules in Series Placard stating "Photovoltaic System Connected" ' & I _101 Location of System Disconnect -50' Represents 3x '<°EMT #6 NM-B w/G Net Meter 5 Modules in Series 6#10THWN-2 Off Grid Over Production Protection Relay Pass 1#10 G THWN-2 "25' -I- - - - - - - thru box - - SunPower SPR Outback Outback Outback Represents 3x#6 NM-B w/G on roof -TL-1- Radian Radian Radian 240 inverter Outback Combining Panel GS8048 Off- GS8048 Off- GS8048 Off- Main Service Panel IT w/disconnect Grid Inverter/ Grid Inverter/ Grid Inverter/ Charger Charger Charger 6 Modules in Series I I I I I I 5, ' "'10' #10 NM-B w/G 1/0 to be supplied Notes: by electrician -See Calculation Sheetfor conductor sizing. Bypass Allconductors are copper unless otherwise noted. ------------------------ -------------------------- - -- Inverter has integral ground-fault protection per NEC 690.5 Rec Room Closet Area 1/0 Main Service Panels-240V 1 Phase Service 1/0 to be sized by 50' engineering I Panel rating of 200A to accommodate 30A System Y 1/0 to be supplied I (SunPower inverter)+200A(Main disconnect)= Disconnect by electrician `45' 230A supply(up to 120%of connected power _ _ 3x sources from residential installations per NEC Critical Panel �• 2"FMC DC Grounding 690.64(B)(2)) f• 2 4/0 RHW-2 Electrode Conductor -Critical Panel-240V 1 Phase Service Panel rating #6 G THHN Batteries solid bare#6 Cu g • 16 Full River DC400- of 200A to accommodate 30A(SunPower inverter) 66v400AH batteries per NEC 250.66(C) +130A(Outback Radian)=160A supply(up to Located outside 120%of connected power sources from residential Placard stating installations per NEC 690.64(B)(2)) 110 to be supplied 'Photovoltaic System Disconnect" Communication Wiring not shown by electrician Bedroom#2 Closet Area Page 7 of 8 10/1/2013 P.O.Box 7627,Avon CO 81620 1 P: 970.227.0272/303.330.4880 1 F: 866.403.3485 1 www.activeenergies.com ACTIVE ENERGIES, Radian Load Center Drawing SOLAR,L.0 Outback Radian Slave 2 Outback Radian Slave 2 Not Shown Load Center -CATS Communication Cable between OAack Radians,Mate3 Ground and HUB -Battery Temperature San"from Outback Radian Master to the Battery Encosum U U— kJ Q Q Q Nottagotter Wiring Legend To Main oCr@ce TO tte TO 46' tten —25' —10, 2"FMC To Critical To Main #6 NM-B #6 NM-B 2#210 THW 1#6 G THHN Outback Radian Master Outback Radian Slave 1 i i Outback Radian Master Outback Radian Slave 1 Load Center Load Center i so i i Ground i w. i ;Ground i i___ ____, STS ns 00 c� z i 1 O c—� z ¢ a ¢ a i i i To FF- To To Relay To Critical To Main eerie To Critical ITO Main attene Gutter Page 8 of 8 10/1/2013 F-Cl.Box 7627,Avon,CO 81620 1 P: 970.227.0272 i 303.330.4880 1 F: 866.403.3485 1 www.active elmlales.Colh • AR PANELS MORE OR UNMATCHED PERFORMANCE, RELIABILITY & AESTHETICS . .. ..� iiii■■■■ X .C.. .. ��� ■■■■i■■i - oil o„ ■■■■■iii S E R I E S ■■■■iii■ • 21 .5%efficiency ii■■■■■■ Ideal for roofs where space is at a premium or MONO■■■■ where future expansion might be needed. SIGNATURETm BLACK X21 -345 PANEL • Maximum performance X21 -335 PANEL Designed to deliver the most energy in HIGHEST EFFICIENCY° demanding real world conditions, in partial shade and hot rooftop temperatures.1,2,3 Generate more energy per square foot • Premium aesthetics X-Series residential panels convert more sunlight to electricity producing 44% SunPower°Signature" Black X-Series panels more power per panel,' and 75% more energy per square foot over 25 blend harmoniously into your roof. The most yea rs.3,4 elegant choice for your home. HIGHEST ENERGY PRODUCTION' Produce more energy per rated watt High year one performance delivers 8-10% more energy per rated watt.3 This advantage increases over time, producing 21% more energy over the first 25 years to meet your needs.' .0zlirs a 12o°ro 3 More Energy 110% Per Rated Watt Maxeon Solar Cells:Fundamentally better. o Engineered for performance, designed for durability. 100% SunPower 2 90% 36%more, CL. year 25 Engineered for peace of mind 21 80°r° Designed to deliver consistent, trouble-free w 70% Conventional energy over a very long lifetime.''s } 6o°%° LO N 50% Designed for durability 0 5 10 Years 15 20 25 ���eRCrpF� The SunPower Maxeon Solar Cell is the only �y V cell built on a solid copper foundation. Virtually a 10% Maintains High PHOTON impervious to the corrosion and cracking that 3 Power at High Temps 2OZFiEro�S� 8% degrade Conventional Panels.''s a No Light-Induced Degradation Awarded to Same excellent durability as E-Series panels. °> 6% g XSerowar E-Series. #1 Ranked in Fraunhofer durability test.10 Q -- { High Average Watts moree°ar9Y 100% power maintained in Atlas 25+ 2 4 % Better Low-Light and comprehensive PVDI Durability test." U /a 2 Spectral Response C ° High-Performance `o Anti-Reflective Glass r 0% sunpowercorp.com • AR PANELS MORE O' SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCT WARRANTY POWER WARRANTY PRODUCT WARRANTY 100% 95% '• 90% 85% Traditional Traditional-11 80% Warranty Warranty 75% 0 5 10 15 20 25 0 5 10 15 20 25 Years Years More guaranteed power:95%for first 5 years,-0.4%/yr.to year 25.$ Combined Power and Product Defect 25 year coverage that includes panel replacement costs.e ELECTRICAL DATA OPERATING CONDITION AND MECHANICAL DATA X21-335-BLK X21-345 Temperature —401F to+185°F (—40°C to+85°C) Nominal Power 12(Pnom) 335 W 345 W Max load Wind:50 psf, 2400 Pa, 245 kg/m2 front&back Power Tolerance +51-0% +51-0% Snow: 112 psf,5400 Pa,550kg/m2 front Avg. Panel Efficiency13 21.1% 21.5% Impact resistance 1 inch (25 mm)diameter hail at 52 mph (23 m/s) Rated Voltage(Vmpp) 57.3 V 57.3 V Appearance Class A+ Rated Current(Impp) 5.85 A 6.02 A Solar Cells 96 Monocrystalline Maxeon Gen III Cells Open-Circuit Voltage (Voc) 67.9 V 68.2 V Tempered Glass High Transmission Tempered Anti-Reflective Short-Circuit Current Isc 6.23 A 6.39 A ( ) Junction Box IP-65 Rated Maximum System Voltage 600 V UL; 1000 V IEC Connectors MC4 Compatible Maximum Series Fuse 20 A Frame Class 1 black anodized, highest AAMA Rating Power Temp Coef. (Pmpp) —0.30%/aC Weight 41 1 b(18.6 kg) Voltage Temp Coef. (Voc) —167.4 mV/aC Current Temp Coef. (Isc) 3.5 mA/aC TESTS AND CERTIFICATIONS REFERENCES: Standard tests UL 1703, IEC 61215, IEC 61730 1 All comparisons are SPR-X21-345 vs.a representative conventional panel:240W, Quality tests ISO 9001:2008, ISO 14001:2004 approx.1.6 m2,15%efficiency. EHS Compliance RoHS,OHSAS 18001:2007, lead-free 2 PVEvolution Labs"SunPower Shading Study,'Feb 2013. Ammonia test IEC 62716 3 Typically 8-10%more energy per watt,BEW/DNV Engineering"SunPower Yield Report,"Jan 2013,with CFV Solar Test Lab Report#12063,Jan 2013 temp.coef. Salt Spray test IEC 61701 (passed maximum severity) calculation. PID test Potential-Induced Degradation free: 1000V 10 4 SunPower 0.25 0/o/yr degradation vs.1.0a/o/yr conv.panel.Campeau,Z.et al. Available listings CEC, UL,TUV,MCS "SunPower Module Degradation Rate,"SunPower white paper,Feb 2013;Jordan,Dirk "SunPower Test Report,"NREL,Oct 2012. 5"SunPower Module 40-Year Useful Life"SunPower white paper,Feb 2013.Useful life is 99 out of 100 panels operating at more than 70a/o of rated power. 6 Out of all 2600 panels listed in Photon International,Feb 2012. 7 1%more energy than E-Series panels,8%more energy than the average of the top 10 panel companies tested in 2012(151 panels,102 companies),Photon International, 1046mm March 2013. [41.2in] 8 Compared with the top 15 manufacturers.SunPower Warranty Review,Feb 2013. 9 Some exclusions apply.See warranty for details. 10 X-Series same as E-Series,5 of top 8 panel manufacturers were tested by Fraunhofer ISE,"PV Module Durability Initiative Public Report,"Feb 2013. 11 Compared with the non-stress-tested control panel.X-Series same as E-Series,tested 46mm in Atlas 25+Durability test report,Feb 2013. [1.81 in] 1559mm 12 Standard Test Conditions(1000 W/m2 irradiance,AM 1.5,25'C). [61.4in] 13 Based on average of measured power values during production. See htto://www.sunpowercorp.com/facts for more reference information. For further details,see extended datasheet:www.sunpowercorp.com/datasheets Read safety and installation instructions before using this product. Designed in California O March 2013 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo,MAXEON,MORE ENERGY.FOR LIFE.,and SIGNATURE are trademarks or registered trademarks of SU n pOWerCo rp.COnl SunPower Corporation.Specifications included in this dotasheet are subject to change without notice. Document#504828 Rev A/LTR_EN 111 . . 11 . SUNPOWER 11 . 111 . . 111 . BENEFITS The World's Standard for Solar L�L L tiulau. raaa►iiJ► High performance and high reliability inverters for use with SunPower photovoltaic panels - the most efficient and reliable panels on earth. High Efficiency Transformerless inverter technology ' enables maximum inverter efficiency of up to 97.1% and CEC efficiency of up to 96.5%. Design Flexibility and Yield l SUNPOWER Maximization J Two maximum power point trackers m dW expand deployment options and maximize energy harvest when SUNPOWER irradiance varies across the array. O 1 Guaranteed Performance Reliable and robust design has a proven - record for durability and longevity. SPR-3000p-TL-1 ' SPR-3600p-TL-1 SPR-4200p-TL-1 = r SPR-5000p-TL-1 SPR-6000p-TL-1 The SunPower SPR-3000p-TL-I, SPR-3600p-TL-1 , SPR-4200p-TL-1 SPR-5000p-TL-1 & SPR-6000p-TL-1 offer proven reliability and superior performance. Their robust and precision designed electronics housing offers UV-resistance and corrosion protection and is suited for both indoor and outdoor (NEMA 4X) SPR-3000p-TL-1 , SPR-3600p-TL-1 , applications. All models come with a standard 10 year warranty. SPR-4200p-TL-1 , SPR-5000p-TL-1 & SPR-6000p-TL-1 Electrical Data SPR-3000p-TL-1 SPR-3600p-TLA SPR-4200p-TLA SPR-5000p-TL-1 SPR-6000p-TL-1 Input Variables(DQ Max.usable power per MPPT 2000 W 3000 W 3000 W 4000 W 4000 W Number of MPPTs 2 MPPT range 160 V...530 V 120 V...530 V 140 V...530 V 200 V...530 V 200 V...530 V Start-up voltage 200 V(adjustable 120 V...350 V) Open circuit voltage 600 V Max.input current for both MPPTs 20.0 A 32.0 A 32.0 A 36.0 A 36.0 A in parallel Max.usable current per MPPT 10.0 A 16.0 A 16.0 A 18.0 A 18.0 A Number of string inputs per MPPT 1 1 1 2 2 Output Variables(AQ Nominal power 3000 W 3600 W 4200 W 5000 W 6000 W 208 V 14.5 A 17.2 A 20.0 A 27.0 A 30.0 A Max.AC output current at: 240 V 14.5 A 16.0 A 20.0 A 23.0 A 28.0 A 277V 12.0A 16.0A 20.0A 20.0A 24.0A Rated frequency 60 Hz cos phi >0.995 Number of grid phases 1 General Electrical Data Max.efficiency 96.9% 97.0% 97.0% 97.1% 97.1% 208 V 96.0% 96.0% 96.0% 96.0% 96.0% CEC efficiency at: 240 V 96.0% 96.0% 96.0% 96.5% 96.5% 277V 96.0% 96.0% 96.0% 96.5% 96.5% Stand-by consumption <8W rSwitching plan transformerless SPR-3000p-TL-1 SPR-3000p-TL 1 Mechanical Data SPR-3600p-TL-1 SPR-5000p-TL-1 Features SPR-3600p-TL-1 SPR-5000p-TLA SPR-4200p-TL 1 SPR 6000p TL 1 SPR-4200p-TL-1 SPR b000p TL 1 Display 16 characters x 2 lines LCD display Warranty 10 years Ambient temperature -25 aC...+60 aC* Conformity to UL 1741,CSA-C22.2 N. 107.1 A1,IEEE 1547,cCSAus (-13 aF...+140 7) standards Additional certifications are available upon request PV array isolation control GFDI Interface RS485 Connections DC&AC:screw terminal block SPR-6000p-TL-1: 96.5%CEC efficiency at 240 VAC Cooling convective cooling,no fan -!O0% : Protection class NEMA U ' C Noise emission <50 dB at 1 meter 95% i DC-switch integrated E / 200 V .9 -145V 859mm x 325mm x 222mm 1052mm x 325mm x 222mm H x W x D (33.8"x 12.8"x 8.7") (41.4"x 12.8"x 8.7") 90% 480 V 21.3 kg 27.0 kg a 0.2 0.4 0.6 0.9 1.Weight (47.3 lbs) (59.5 lbs) Fraction of rated output power,Pgo/PgG,m, 'Power dervfl,a6vve 55 T(13 I'D for SPR3000p-TL-1,SPR 3600p-TL-1 and SPR 4200p-TL-1 and v6ove 50T X122°Fl far SPR-5W0p-T1-I and SPR 6000pTL-1 About SunPower SunPower designs,manufactures,and delivers high-performance solar electric technology worldwide.Our high-efficiency solar cells generate up to 50 percent more power than conventional solar cells.Our high-performance solar panels and trackers deliver significantly more energy than competing systems. SUNPOWER and the SUNPOWER logo are trademarks or registered trademarks of SunPower Corporation. $U n powe rco rp.CO m ©February 2012 SunPower Corporation.Al rights reserved.SpeciFications included in this datasheet are subject to change without notice. 500545 500545 R ev.B/LT EN • a : 111 • • • • - � The new OutBack Power Technologies Radian Series GS8048 Complete system interface using the OutBack MATE3 and HUB inverter/charger provides a comprehensive answer for grid- Communications Manager enables the Radian Series GS8048 to interactive and off-grid/stand-alone power systems.Based upon be connected with other OutBack Power electronics providing a proven foundation of reliable technology,but engineered industry leading integration and a robust,scalable power solution. from the ground up to simplify the design,distribution,installation Up to 10 units can be connected in parallel for systems up to 80kW and implementation of energy storage,the standardized structure continuous power output. and integration with the GS Load Center make it easy to provide a successful solution to any power requirement,anywhere. The Radian Series utilizes a durable stainless steel face with galvanized steel enclosure,providing you with OutBack's signature Incorporating a powerful DC to AC true sinewave inverter,battery ruggedness with a sleek,compact and modern appearance. charger and dual AC inputs,its 120/240V split-phase output provides a total power solution which seamlessly integrates with OutBack Power inverter/chargers are the only choice when you need a dependable power solution for your home or business. traditional North American wiring practices. Unique dual power module design provides high efficiency at both low and full power operation,while providing redundancy for critical applications.The modular design also allows easy field Outj&nck servicing of installed systems. POWER'" member of The ffl�k Group- www.outbackpower.com Radian Series Specifications GS8048 Nominal DC Input Voltage 48 Vdc Continuous Output Power at 25°C 8000 VA AC Output Voltage/Frequency 120/240 Vac/60 Hz Continuous AC Output Current at 25°C 33.3 Aac at 240 Vac Idle Consumption-Invert mode,no load 30W CEC Weighted Efficiency 90% Total Harmonic Distortion Maximum total harmonic <5% Maximum single voltage harmonic <2% Output Voltage Regulation ±2% Maximum Output Current 1 ms peak 100 Aac at 240 Vac,200 Aac at 120 Vac 100 ms RMS 70.7 Aac at 240 Vac Overload Capability 100 ms surge 16.97 kVa 5 seconds 12 kVa 30 minute 9 kVa AC Input Voltage Range(Adjustable) (L1 or L2)70 to 140 Vac AC Input Frequency Range 54 to 66 Hz Grid-Interactive Voltage Range(IEEE) (L1 or L2)108 to 132 Vac Grid-Interactive Frequency Range(IEEE) (L1 or L2)59.3 to 60.5 Hz Maximum AC Input Current 50 Aac at 240 Vac Continuous Battery Charge Output 115 Adc Temperature Range Operating 0 to 50oC(power derated above 25°C) Storage -40 to 60°C DC Input Voltage Range 40 to 64 Vdc Accessory Ports Remote Temperature Sensor and MATE3/HUB Communications Non-volatile Memory Yes Field Upgradable Firmware Yes Chassis Type Vented Certifications ETL Listed to UL1741 CSA C22.2 No.107.1 Warranty Standard 5 year Warranty Weight(lbs/kg) Unit 125/56.7 Shipping 140/63.5 Dimensions H x W x D(in/cm) Unit 28 x 16 x 8.7/71.1 x 40.6 x 22.1 Shipping 14.5 x 34.5 x 21 /36.8 x 87.6 x 53.3 Available From: VutXack POWER'" member of The dH�,Group- Corporate Office: European Office: Asia Office: Latin American Office: 5917 195th St.NE Hansastrasses 8 Suite 1903,19/F.,Tower 1 15105 Cedar Bluff PI. Arlington,WA 98223 USA D-91126 33 Canton Road,Tsun Sha Tsui Wellington,FL 33414 USA Phone:(360)435.6030 Schwabach,Germany China Hong Kong City,Kowloon Phone:(561)792.9651 Fax:(360)435.6019 Phone:+49.9133.79889.0 Hong Kong Fax:(561)792.7157 Fax:+49.9122.79889.21 Phone:+852.2736.8663 Fax:+852.2199.7988 www.outbackpower.com 02/12 Model DC400=6 - (415AH/6 Volt) j 1 ® Industry Reference: L16 BCl Group: 903 DEEP CYCLE SERIES CONSTANT . • CUT OFF VOLTAGE 30M 45M 1H 2H 3H 5H 8H 10H 12H 20H 24H Wcell 1.75V 386.6 285.0 231.5 123.4 93.9 65.9 45.1 37.4 31.8 20.8 17.4 CAPACITY RESERVE @25 AMPS @75 AMPS 885 Minutes 229 Minutes SPECIFICATIONS Nominal Voltage 6 Volt 20 Hour Rate(20.8A to 5.25 Volts) 415AH Rated Capacity(20 hour rate) 41SAH Capacity 77°F(25°C) 10 Hour Rate(37.4A to 5.25 Volts) 374AH Total Height lincmdingtenninalsl 424mm(16.69") 5 Hour Rate (68A to 5.1 Volts) 340AH Dimensions Height 404m(15.90") Internal Resistance Full charged Battery 77T(25°C) 1.6m Q Length 295mm(11.61") 104°F(40°C) 102% Capacity Affected 77T(25°C) 100% Width 179mm(7.04") by Temperature Weight 56.Okg(123.2 lbs) (20 Hour Rate) 32°F(0°C) 85% 5°F(-15°C) 65% Capacity after 3 month storage 91% DISCHARGE . ' Self-Discharge Capacity after 6 month storage 82% 6-Volt Battery Temperature:77F(25°C/ 77°F(25°C) Capacity after 12 month storage 64% 6.6 Max. Discharge 01 6.o Current 77°F(25°C) 2000A(5s) o s.s 6'0 -68A 37.4A 20.8A Terminal Standard DT E 4.1 415A 240A 40 Cycle Initial Charging Current<0.2 x C20 Charging y 7.25V - 7.45V/77°F(25°C) 1 2 5 10 20 60 2 5 IO 20 Minutes Hour, (Constant Voltage) Discharge Time Float 6.8V - 6.9V/77°F(25°C) SIZE & DETAILED ILLUSTRATION 295mm 179mm 272mm 100mm j 210mm mOO� Terminal(Unit:mm) �\ O _ Positive Negative nz E O a o � + O � This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries.Cell and battery designs/specifications are subject to modifications without notice.Contact Fullriver for the latest information. G LCD Cn The Right Way! F47 S-5-U Clamp The S-5-U clamp is by far our most LCD popular and most versatile clamp. It fits about 85% of the standing seam profiles manufactured in North America—including most structural and architectural profiles. It can be used on Nvertically oriented seams and, by rotating Othe clamp 90 degrees, it can also be used C on most horizontal 2" seam profiles. L Its simple design,generous dimensioning and multiple hole orientations are what make the S-5-U clamp so versatile for use with the S-5!°snow retention products, Q such as ColorGard°,as well as with other 0 heavy-duty applications. 0) Installation is as simple as setting the = specially patented round-point setscrews 7 into the clamp, placing the clamp on }' the seam,and tightening them to the specified tension.Then,affix ancillary items using the bolt provided with the �+ product. Go to www.S-5.com/tools N for information and tools available for O EC properly attaching and tensioning S-5! V clamps. Ln s S-5-U Mini Clamp W v � The S-S-U Mini is a bit shorter than the 5-5-U and has one setscrew rather than two.The mini is the choice for attaching Q all kinds of rooftop accessories: signs, t+ walkways, satellite dishes,antennas, IN > rooftop lighting, lightning protection The S-5-U clamp is our M systems, solar arrays,exhaust stack most popular and versatile M bracing,conduit,condensate lines, clamp, fitting about 85% of mechanical equipment—just about LO anything!* the standing seam profiles N OO in North America. 1 ^ *5-5!mini clamps are not compatible with,and should not M M i be used with S-5!SnoRail."/S no Fence'"or ColorGard®snow WM retention systems. W 0 patented The strength of the S-5-U clamp is in its simple design. The setscrews will slightly dimple the metal seam material but not pierce leaving roof The Right Way! The S-5-U and S-5-U Mini clamps are each furnished with S-5-U Clamp the hardware shown to the right.Each box also includes a bit tip for tightening setscrews using an electric screw M10 hole gun.A structural aluminum attachment clamp, S-5-U located a part mm) g p 2.00" from edge of part is compatible with most common metal roofing materials (51.00 mm) excluding copper.All included hardware is stainless steel. Please visit www.S-5.com for more information including CAD details,metallurgical compatibilities and AL specifications. 1.so° The S-5-U clamp has been tested for load-to-failure results (38.00 mm) on most major brands and profiles of standing seam roofing. The independent lab test data found at www.S-5.com can be used for load-critical designs and 0.901, 0.54" applications.S-5!' holding strength is unmatched in the (23.00 m ) (1 .00 mm industry. Example Profiles �� AZ'Note:Install both 0�mm) 40" setscrews onsame side of clamp. 1.5 (38.00 S-5-U Mini Clamp M8 holes centered 1.18" on part (30.00 mm) 1.50" (38.00 mm) 0.90" For horizontal seams under 0.65"do not use this clamp.Visit (23.00 mm) .54" m www.S-5.com for more detailed information and proper (14.)0 clamp to use. If 0.40" (10.00 mm) 1.50" (38.00 mm) Please note:All measurements are rounded to the second decimal place. S-5!®Warning!Please use this product responsibly! Distributed by Products are protected by multiple U.S.and foreign patents.Visit the website at www.5-5.com for complete information on patents and trademarks.For maximum holding strength,setscrews should be tensioned and re-tensioned as the seam material compresses.Clamp setscrew tension should be verified using a calibrated torque wrench between 160 and 180 inch pounds when used on 22ga steel, and between 130 and 150 inch pounds for all other metals and thinner gauges of steel.Consult the S-5! webs ite at www.5-5.com for published data regarding holding strength. Copyright2013,Metal Roof Innovations,Ltd.S-S!products are patented protected. 5-51 aggressively protects its patents,trademarks and copyrights.Version 031113. 0 SOLARMOUM Technical . . . - - ::� UNIRAC A I-0CTI GROUP COMPANY SolarMount Technical Datasheet Pub 110818-ltd V1.0 August 2011 SolarMount Module Connection Hardware.................................................................. 1 BottomUp Module Clip.................................................................................................1 MidClamp ....................................................................................................................2 EndClamp....................................................................................................................2 SolarMount Beam Connection Hardware......................................................................3 L-Foot...........................................................................................................................3 SolarMountBeams..........................................................................................................4 SolarMount Module Connection Hardware SolarMount Bottom Up Module Clip Part No. 302000C Washer Bottom Up Clip material: One of the following extruded aluminum Bottom Nut (hidden..see alloys: 6005-T5, 6105-T5, 6061-T6 t up Clip note*) Ultimate tensile: 38ksi,Yield: 35 ksi • Finish: Clear Anodized • Bottom Up Clip weight: -0.031 Ibs (14g) Beam Bolt Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized UNIRAC documents • Assemble with one'/4"-20ASTM F593 bolt, one '/"-20ASTM F594 serrated flange nut, and one 1/4"flat washer 'X Use anti-seize and tighten to 10 ft-Ibs of torque Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- _ _ party test results from an IAS accredited laboratory Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Load Factor, FRIP 0 Ibs(N) Ibs (N) FS Ibs(N) CD Tension,Y+ 1566(6967) 686(3052) 2.28 1038(4615) 0.662 t Y Transverse,X± 1128(5019) 329(1463) 3.43 497(2213) 0.441 i R10 X Sliding, Z± 66(292) 1 27(119) 2.44 41 (181) 0.619 Dimensions specified in inches unless noted a 0 UNIRAC . - , . , , - - ::e A I HLTI GROUP COMPANY SolarMount Mid Clamp Part No.302101 C,302101 D,302103C,302104D, 302105D,302106D • Mid clamp material: One of the following extruded aluminum Mid 5 4 Fla rr N Bolt alloys: 6005-T5, 6105-T5, 6061-T6 e u Clamp '' .._ Ultimate tensile: 38ksi,Yield: 35 ksi Finish: Clear or Dark Anodized l Mid clamp weight: 0.050 Ibs (23g) Allowable and design loads are valid when components are `-ems assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac'/4"-20 T-bolt and one '/"-20 ASTM F594 serrated flange nut ., Use anti-seize and tighten to 10 ft-Ibs of torque Beam Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- party test results from an IAS accredited laboratory Applied Load Average Allowable Safety Design Resistance 3.00 D«? - Direction Ultimate Load Factor, Load Factor, BE WiEEN MQUULES Ibs(N) Ibs(N) FS Ibs(N) Tension,Y+ 2020(8987) 891 (3963) 2.27 1348(5994) 0.667 Transverse,Z± 520 (2313) 229(1017) 2.27 346(1539) 0.665 * Sliding, X± 1194(5312) 490(2179) 2.44 741 (3295) 0.620 ■X Dimensions specified in inches unless noted SolarMount End Clamp Part No.302001C,302002C,302002D,302003C, 302003D,302004C,302004D,302005C,302005D, 302006C,302006D,302007D,302008C,302008D, 302009C,302009D,302010C,302011C,302012C End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 Bolt Ultimate tensile: 38ksi,Yield: 35 ksi • Finish: Clear or Dark Anodized • End clamp weight: varies based on height: 0.058 Ibs (26g) End Clamp Allowable and design loads are valid when components are Serrated assembled according to authorized UNIRAC documents Flange Nut Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble with one Unirac'/"-20 T-bolt and one '/"-20 ASTM F594 Bea serrated flange nut Use anti-seize and tighten to 10 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- Y party test results from an IAS accredited laboratory Modules must be installed at least 1.5 in from either end of a beam �-x L.s Applied Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Loads Factor, Ibs(N) Ibs(N) FS Ibs(N) 4) � H Tension,Y+ 1321 (5876) 529(2352) 2.50 800 (3557) 0.605 ROOM f"° Transverse, Z± 63(279) 14(61) 4.58 21 (92) 0.330 f Dimensions specified in inches unless noted Sliding,X± 142 (630) 52(231) 2.72 79(349) 0.555 a 0 . Technical . , , - - ::� UNIRAC A I-0CTI GROUP COMPANY SolarMount Beam Connection Hardware SolarMount L-Foot Part No. 304000C, 304000D • L-Foot material: One of the following extruded aluminum alloys: 6005- { • 6105-T5, 6 Ult imate tensile: 38ks i,Yield: 35 ksi • Finish: Clear or Dark Anodized J L-Foot weight: varies based on height: —0.215 Ibs(98g) • Allowable and design loads are valid when components are Bea assembled with SolarMount series beams according to authorized Bolt UNIRAC documents I L-Foot For the beam to L-Foot connection: •Assemble with one ASTM F593 W-16 hex head screw and one errated ASTM F594 W serrated flange nut Flange Nu ' • Use anti-seize and tighten to 30 ft-Ibs of torque Resistance factors and safety factors are determined according to part * ' 1 section 9 of the 2005 Aluminum Design Manual and third-party test Y results from an IAS accredited laboratory * NOTE: Loads are given for the L-Foot to beam connection only; be X sure to check load limits for standoff, lag screw, or other attachment method a Applied Load Average Safety Design Resistance 3X 50T Direction Ultimate Allowable Load Factor, Load Factor, ��nunvr+ Ibs(N) Ibs(N) FS Ibs(N) 4) Sliding,Z± 1766(7856) 755(3356) 2.34 1141 (5077) 0.646 Tension,Y+ 1859(8269) 707(3144) 2.63 1069(4755) 0.575 Dimensions specified in inches unless noted Compression,Y- 3258(14492) 1325(5893) 2.46 2004(8913) 0.615 Traverse,X± 486(2162) 213(949) 2.28 323(1436) 0.664 a 0 SOLARMOuNT Technical Datasheets � UNIRAC A I HLTI GROUP COMPANY SolarMount Beams Part No. 310132C, 310132C-B, 310168C, 310168C-B, 310168D 310208C, 310208C-B, 310240C, 310240C-B, 310240D, 410144M, 410168M, 410204M, 410240M Properties Units SolarMount SolarMount HD Beam Height in 2.5 3.0 Approximate Weight(per linear ft) plf 0.811 1.271 Total Cross Sectional Area in 0.676 1.059 Section Modulus (X-Axis) in' 0.353 0.898 Section Modulus (Y-Axis) in3 0.113 0.221 Moment of Inertia (X-Axis) in 0.464 1.450 Moment of Inertia (Y-Axis) in 0.044 0.267 Radius of Gyration (X-Axis) in 0.289 1.170 Radius of Gyration (Y-Axis) in 0.254 0.502 f SLOT FOR T-BOLT OR SLOT FOR T-BOLT OR 1.728 11/" HEX HEAD SCREW HEX HEAD SCREW 2X SLOT FOR SLOT FOR BOTTOM CLIP 2.500 BOTTOM CLIP T 3.000 1.316 SLOT FOR q I —r 3/8" HEX BOLT SLOT FOR 1.385 3�" HEX BOLT- rL77 U .387 .750 1.207 Y Y 1.875 A A w X w X SolarMount Beam SolarMount HD Beam Dimensions specified in inches unless noted a