HomeMy WebLinkAboutB13-0438 Specifications.pdf B13-0438
ACTIVE
ENERGIES
SOLAR..
Solar installation Information
Vendor: Active Energies Solar LLC
PO Box 7627
Avon, CO 81620
(970-306-423 3/info @activeenergies.com)
Site: Nields Residence
763 Potato Patch Dr. #3
Vail, CO 81657
All AC wiring to be completed by a Colorado licensed master electrician
All DC wiring to be overseen by NABCEP certified installer
Minimum Designed Temperature: -40°F
Maximum Ambient Design Temperature: 140°F
Panel Arrangement:flush mounted
5 columns of 5 panels oriented in the landscape position, on the east facing roof split
around the existing thermal system
11
r,
not to scale
RECEIVED
By David Rhoades at 9:08 am, Oct 02, 2013
Page 1 of 4 9/29/2013
P.O.Box 7627,Avon,CO 81620 1 P: 970.227.0272/303.330.4nO 1 F: 866.403.3485 1 wwwv.wtiveenergies.corn
ACTIVE
ENERGIES
SOLAR..
Calculations
6.25kW System Size (STC)
25 Phono Solar PS250P-20/U solar panels @ 250 watts
25 Enphase M-215 240 micro-inverters—2 branches of 15110 units each
Fixed array tilt angle: 18.430
Array azimuth: 120° (where 180°is south)
Estimated annual power production: 8,325kWh
Maximum PV System Voltage: 690.7
Voc= 37.8V/module
37.8V x 1 module= 37.8V
Temperature correction factor 690.7(A)
STC =25°C, Temperature Coefficient (Voc) = -0.31%/°K
(298°K- 233°k) = 65°K
37.8V+ (-65°K x (-0.31%/°K x 37.8V) x 1 module) 45AV
Temperature correction factor Table 690.7
For-40°F use 1.25
37.8V x 1.25 =47.3V
Maximum PV Source Circuit(String) Current: 690.8 (A)(1)
ISM = 8.7A
8.7A x 1.25 = 10.9A
Maximum PV Output Circuit(Array) Current: 690.8 (A)(2)
10.9A x 1 strings = 10.9A
Inverter Output Circuit Current: 690.8 (A)(3)
.9A @ 240V
John Wiles, "Photovoltaic Power Systems and the National Electrical Code: Suggested
Practices", 2005,pp. El-E25.
Page 2 of 4 9/29/2013
P.O.Box 7627,Avon,CO 81620 1 P: 970.227.0272/303.330.4880 1 F: 866.403.3485 1 wwwv.wtiveenergies.corn
ACTIVE
ENERGIES
SOLAR..
Conductor Sizing
Pass Thru Box on Roof to PV Combining Panel (for a 15 panel circuit):
Nameplate maximum continuous output current:
.9A
Maximum Output Power 215 Watts AC
215W-240 V= .9A
.9A x 15 inverters = 13.5A per branch
13.5A x 125%= 16.9A
#10 THWN-2 or NM-B Table 310.16
40A (90°C column, see note 240.4(D))
Conduit fill adjustment Table 310.15 (13)(2)(a)
For 6 current carrying conductors use .70
40A x .70 =28A
Temperature correction factor Table 310.16
No Temperature Correction
PV Combining Panel to Disconnect to Service Panel (for a 25 micro-inverters):
Nameplate maximum continuous output current:
.9A
Maximum Output Power 215 Watts AC
215W-240 V= .9A
.9A x 25 inverters =22.5A per branch
22.5A x 125%=28A
#10 THWN-2 or NM-13 Table 310.16
40A (90°C column, see note 240.4(D))
Conduit fill adjustment Table 310.15 (13)(2)(a)
No Conduit Fill Adjustment
Temperature correction factor Table 310.16
No Temperature Correction
Overcurrent Protection Device per circuit
PV Combining Panel - 2 x 20A two pole breaker Per Manufacturer Specification
Main Service Panel 1 x 30A two pole breaker
Page 3 of 4 9/29/2013
P.O.Box 7627,Avon,CO 81620 1 P: 970.227.0272/303.330.4880 1 F: 866.403.3485 1 wwwv.wtiveenergies.corn
M
VL p�
N
W N ti � °
�, . 2 -0
Y
o m > m
p ltJ t N ¢ N N N U
L N O U O �'�? I.C) °O O C 'O O m E W
d N i M o0 N M T 2i U 7 p > 'p O C O O Z
c Y o CD
aoc 0Y1 N a � E m o o
aw)om o
E o o aU E Q cnMoo m W a�(� o _ i o n
o 11 11 C VJ
. E o C U U C O C p > Vv o a �c-
�m
Eo � L — 3 o � � Z >
cli
m XO a ao a o
�N a Q
n
O w .iv
aU a5 r m C bo v o�A> ° 22 O ¢U N ED Z N O N N Co
clq
co N O c o Q c c o c o N c �0 r ° ol
Z
.y
U
Y c a V m C
O o N O U N
Z cc C c c c U O:2 Z -
� T O w a
W 00
U� M
_U
O C C C c C
M
°>
El. O
o � �
FL o Q
00
'>W
Z5 _m U
Z
O rL
O O Q
O
E00
p a_ 00
S $ YO C C5 O
U c 'c a�
� E Q a m a
aria i. zZ L) maa - O
C�j CL
fn _ ¢ M
M7Y o v W~C~.7 JO
Co Cl) J C
M o N N
L M N z O
-O '(-a ~ _
CO = N
o 0 u c C Q
pU ao0 0o
�✓ d > U V T QI
CO �
00
O
U
C
m
0
3 W Q
W O
23 m E¢ �O
E N
S y m N
O =Z O N C 'U
°U
r �SJ2 CG
o y _ m
E J m a a0
a Q C.5 U o
@ w P,
Q � U
N
_N
N
g
O
O C N-. E7
U 0 ��
C
y U U O
m N W
m @ ¢ E
m a� O
m w o
H �
bQ
C�
ABOUT PHONO SOLAR
Phono Solar Technology Co., Ltd. is one of the world's
leading renewable energy product manufacturers and a well _
trusted brand provider. The Phono Solar brand has become
synonymous with high performing, top quality photovoltaic --
panels that are ideal for use in large scale power plants,
commercial and residential installations.
I pill • • 1 1; • gins • •
HIGH PERFORMANCE SOLAR ■ ■ ■ ° ■
MODULES -
RELIABLY HIGH YIELDS QUALITY ASSURANCE WARRANTIES
• High efficiency solar cells together • Durability assured in even the • 10-year product warranty*
with high transmission textured glass harshest environments with AMMONIA • 25-year performance warranty*
deliver module efficiency of over 16.0%, CORROSION, SALT MIST CORROSION, • Free module recycling through PV
leading to minimized installation costs and FIRE TEST certifications. Cycle Association membership**
and maximized system output. e Certified to withstand increased snow
• High output due to excellent and wind loads of up to 5400Pa.
performance in weak-light conditions. • Manufacturing facility certified by ISO
• Higher specific yields due to positive 9001, ISO 14001 and OHSAS 18001.
power sorting. • Internal quality control with standards
• Product quality is assured through the higher than both IEC and UL.
use of branded components.
aooucr t\
' PPAa�oP PV CYCLE
Clean Energy Coundl
* IN COMPLIANCE WITH OUR WARRANTY TERMS AND CONDITIONS.
** IN PV CYCLE MEMBER COUNTRIES ONLY,SEE: WWW.PVCYCLE.COM
ONYX . Phon& Solar
MECHANICAL CHARACTERISTICS ABSOLUTE MAXIMUM RATING
Polycrystalline 156mm x 156mm square, 6 x 10 pieces in series Parameter Values
Length: 1640mm(64.6 inch) Operating Temperature From -40 to+85°C
Width: 992mm(39.1 inch) Typical Application 20V DC
Height:45mm (1.8 inch) Hail Diameter @ 80km/h Up to 25mm
20kg(44.1lbs) Surface Maximum Load Capacity Up to 5400Pa
3.2mm toughened glass Maximum Series Fuse Rating 15A
Anodized aluminium alloy IEC Application Class(IEC 61215) A
0.90m wire(o4m.l Fire Rating(UL 1703) C
6 pieces Schottky by-pass diodes 1000V DC(IEC 61215)
Maximum System Voltage
IP 65 rated 1000V DC(UL 1703)
ELECTRICAL TYPICAL VALUESI,2
Model Rated Power(Pmpp) Tolerance Rated Current(Impp) Rated Voltage(V,pp) Short Circuit Current(LO Open Circuit Voltage(V.J I Module Efficiency ft
PS235P-20/U 235W 0-+5W 7.94A 29.6V 8.40A 373V 14.44
PS240P-20/U 240W 0-+5W 8.06A 29.8V 8.50A 37.5V 14.75
PS245P-20/U 245W 0-+5W 8.184 30.OV 8.60A 37.7V 15.06
PS250P-20/U 250W 0--+5W 8.30A 30.2V 8.70A 37.8V 15.37
PS255P-20/U 255W 0-+5W 8.42A 30.4V 8.80A 37.9V 15.67
PS260P-20/U 260W 0-+5W 8.53A 30.6V 8.90A 38.OV 15.98
PS265P-20/U 265W 0--+5W 8.61A 30.8V 9.004 38.1V 16.29
DIMENSIONS TEMPERATURE CHARACTERISTICS
NOCT(Nominal Operation Cell Temperature)860133.861
1360153.54)
Voltage Temperature Coefficient E45C±
Current Temperature •.-
e
Section A-A WEAK LIGHT PERFORMANCE
i
s
u
900(35.43) 1110.43)
1000 1 1
800 0.8 0.996
45(1.77) 600 0.6 0.99
frame(block)
400 0.4 0.983
L 1 200 0.2 0.952
100 1 0.1 1 0.921
35(1.38)
PACKING CONFIGURATION
40'HQ
Pieces per pallet 22
Pallets per container 28
1640(64.57) Note:mm(inch)
616
PARTNER INFORMATION
Note: This datasheet summarises product warranty and specifications, which are subject to
change without notice. The exact module specification will be subject to the description in the
sales contract. Further information can be found on our website: www.phonosolar.com
1.Defined as standard deviation of thousands measurements.Absolute power values depend on
the measuring system.They can differ by+/-5%from one measuring system to another.
2. Measurement conditions under irradiance level of Standard Test Condi lons(STC): 1000W/m',
Air mass 1.5 Spectrum,cell temperature of 25°C.
www.phonosolar.com EN-U-P-BB-1210
re] ENPHASE MICROINVERTER M215
.� [e] enphae
E N E R G Y
The Enphase Energy Microinverter System improves energy harvest,
increases reliability, and dramatically simplifies design, installation and
management of solar power systems. The Enphase System includes the
le U fd I I I IIU UII IVCI LUI, tI r--.Iy CUII IIII I IIUI IL c1LIUI lJ VcUWy, al IU EI IIJy l ILUI 1I,
Enphase's monitoring and analysis software.
- Maximum energy production
P R o D u c T I v E - Resilient to dust, debris and shading
- Performance monitoring per module
- System availability greater than 99.8%
R E i A a E - No single point of system failure
SMART - Quick & simple design, installation and management
- 24/7 monitoring and analysis
S A F E - Low voltage DC
- Reduced fire risk cl �s c
MICROINVERTER TECHNICAL DATA
Input Data (DQ M215-60-2LL-S22623
M215-60-2LL-S22-NA/S23-NA(Ontario)
Recommended maximum input power(STC) 260W
Maximum input DC voltage 45V
Peak power tracking range 22V—36V
Operating range 16V—36V
Min./Max.start voltage 26.4W45V
Max. DC short circuit current 15A
Max. input current 10.5A
Output Data (AQ @208 Vac @240 Vac
Maximum output power 215W 215W
Nominal output current 1.0 A* 0.9 A*
Nominal voltage/range 208W1 83V-229V 240W21 1 V-264V
Extended voltage/range 208W1 79V-232V 240W206V-269V
Nominal frequency/range 60.0/59.3-60.5 60.0/59.3-60.5
Extended frequency/range 60.0/59.2-60.6 60.0/59.2-60.6
Power factor >0.95 >0.95
Maximum units per 20A branch circuit 25(three phase) 17(single phase)
Maximum output fault current 1.05 Arms,over 3 cycles;25.2 Apeak, 1.74ms duration
*Arms at nominal voltage
Efficiency
CEC weighted efficiency 96.0%
Peak inverter efficiency 96.3%
Static MPPT efficiency(weighted, reference EN 50530) 99.6%
Dynamic MPPT efficiency(fast irradiation changes, reference EN 50530) 99.3%
Night time power consumption 46mW
Mechanical Data
Ambient temperature range -40°C to+65°C
Operating temperature range(internal) -40°C to+85°C
Dimensions(WxHxD) 17.3 cm x 16.4 cm x 2.5 cm(6.8" x 6.45"x 1.0")*
Weight 1.6 kg (3.5 Ibs)
Cooling Natural convection—no fans
Enclosure environmental rating Outdoor—NEMA 6 without mounting bracket
Features
Compatibility Pairs with most 60-cell PV modules
Communication Power line
Warranty 25-year limited warranty
Compliance UL1741/IEEE1547, FCC Part 15 Class B
CAN/CSA-C22.2 NO.0-M91,0.4-04,and 107.1-01
Enphase Energy, Inc. 06/13/2011
201 1St Street, Petaluma, CA 94952
877 797 4743 www.enphase.com ®Printed on 100 percent recycled paper.
Tall Catalog 2009
Flashing Assembly
ZiIIaTM Flashing is superior to all comparable products on the market, and can be used with any available standoff and or
mounting components. The longevity of this product is outstanding, outlasting the roof and the solar system simply due to
innovative engineering that protects all of the degradable components.
The ZillaTM Flashing Assembly is sold in a 4 piece component set. This assembly includes:double stud bolt,silicone washer,
flashing and base plate.Pieces may be purchased separately upon request.
ZiIIaTM Flashing Components
Product Product Number Description Materials Size Weight Color #Per Package
Double Stud Assembly Threaded double stud bolt&
a high temperature silicone
washer that is encapsulated Zinc plated
in a compression zone to steel and a high 3/8"—16 Threads
DS-ZP eliminate water infiltration 0.170 lb. Silver 25
makes up the double stud, temperature 1.5"w x 5/8"tall x 2
assembly.With no exposed silicone washer
parts to degrade,it is designed
to outlast the solar system.
FLSH-CC Custom 0.640 lb. Custom
FLSH-CU Copper 1.37 lb. I Copper
FLSH-SS Stainless Steel 0.640 lb. Silver
FLSH-SSBLK Sits on top of the base plate, Stainless Steel 0.640 lb. Black
Flashing FLSH-GS and is attached with the Galvanized Steel 8"w x 10"t 0.640 lb. Silver 6
double stud assembly.
FLSH-GSBLK Galvanized Steel 0.640 lb. Black
FLSH-AL Aluminum 0.274 lb. Silver
FLSH-ALBLK Aluminum 0.274 lb. I Black
BP-AL Aluminum 0.179 lb.
Base plate is attached to the
roof with lag bolts.Flashing
Base Plate _ BP-SS is attached to the base Stainless Steel 3"w x 3 7/8"t 0.418 lb. Silver 6
plate using the double stud
assembly.
BP-GS Galvanized Steel 0.418 lb.
ZiIIaTM Flashing Assembly
Product Product Number Description Materials #Per Package
Flashing Base Plate Double Stud
FLSH-CC
BP-AL
FLSH-CU
DS-ZP
FLSH-SS
FLSH-SSBLK BP-SS All four pieces of the ZiIIaTM'Flashing
Assembly includes the double stud, See above 6
FLSH-GS washer,flashing and base plate for materials list
FLSH-GSBLK
FLSH-AL BP-GS DS-SS
FLSH-ALBLK
3
0
SOLARMOUM Technical . . . - - ::� UNIRAC
A I-0CTI GROUP COMPANY
SolarMount Technical Datasheet
Pub 110818-ltd V1.0 August 2011
SolarMount Module Connection Hardware.................................................................. 1
BottomUp Module Clip.................................................................................................1
MidClamp ....................................................................................................................2
EndClamp....................................................................................................................2
SolarMount Beam Connection Hardware......................................................................3
L-Foot...........................................................................................................................3
SolarMountBeams..........................................................................................................4
SolarMount Module Connection Hardware
SolarMount Bottom Up Module Clip
Part No. 302000C
Washer Bottom Up Clip material: One of the following extruded aluminum
Bottom Nut (hidden..see alloys: 6005-T5, 6105-T5, 6061-T6
t up Clip note*) Ultimate tensile: 38ksi,Yield: 35 ksi
• Finish: Clear Anodized
• Bottom Up Clip weight: -0.031 Ibs (14g)
Beam Bolt Allowable and design loads are valid when components are
assembled with SolarMount series beams according to authorized
UNIRAC documents
• Assemble with one'/4"-20ASTM F593 bolt, one '/"-20ASTM F594
serrated flange nut, and one 1/4"flat washer
'X Use anti-seize and tighten to 10 ft-Ibs of torque
Resistance factors and safety factors are determined according to
part 1 section 9 of the 2005 Aluminum Design Manual and third-
_ _ party test results from an IAS accredited laboratory
Module edge must be fully supported by the beam
* NOTE ON WASHER: Install washer on bolt head side of assembly.
DO NOT install washer under serrated flange nut
Applied Load Average Allowable Safety Design Resistance
Direction Ultimate Load Factor, Load Factor,
FRIP 0
Ibs(N) Ibs (N) FS Ibs(N) CD
Tension,Y+ 1566(6967) 686(3052) 2.28 1038(4615) 0.662
t
Y Transverse,X± 1128(5019) 329(1463) 3.43 497(2213) 0.441
i R10 X Sliding, Z± 66(292) 1 27(119) 2.44 41 (181) 0.619
Dimensions specified in inches unless noted
a
0
UNIRAC
. - , . , , - - ::e
A I HLTI GROUP COMPANY
SolarMount Mid Clamp
Part No.302101 C,302101 D,302103C,302104D,
302105D,302106D
• Mid clamp material: One of the following extruded aluminum
Mid 5 4 Fla rr N Bolt alloys: 6005-T5, 6105-T5, 6061-T6
e u
Clamp '' .._ Ultimate tensile: 38ksi,Yield: 35 ksi
Finish: Clear or Dark Anodized
l Mid clamp weight: 0.050 Ibs (23g)
Allowable and design loads are valid when components are
`-ems assembled according to authorized UNIRAC documents
• Values represent the allowable and design load capacity of a single
mid clamp assembly when used with a SolarMount series beam to
retain a module in the direction indicated
• Assemble mid clamp with one Unirac'/4"-20 T-bolt and one '/"-20
ASTM F594 serrated flange nut
., Use anti-seize and tighten to 10 ft-Ibs of torque
Beam Resistance factors and safety factors are determined according to
part 1 section 9 of the 2005 Aluminum Design Manual and third-
party test results from an IAS accredited laboratory
Applied Load Average Allowable Safety Design Resistance
3.00 D«? - Direction Ultimate Load Factor, Load Factor,
BE
WiEEN MQUULES
Ibs(N) Ibs(N) FS Ibs(N)
Tension,Y+ 2020(8987) 891 (3963) 2.27 1348(5994) 0.667
Transverse,Z± 520 (2313) 229(1017) 2.27 346(1539) 0.665
* Sliding, X± 1194(5312) 490(2179) 2.44 741 (3295) 0.620
■X
Dimensions specified in inches unless noted
SolarMount End Clamp
Part No.302001C,302002C,302002D,302003C,
302003D,302004C,302004D,302005C,302005D,
302006C,302006D,302007D,302008C,302008D,
302009C,302009D,302010C,302011C,302012C End clamp material: One of the following extruded aluminum
alloys: 6005-T5, 6105-T5, 6061-T6
Bolt Ultimate tensile: 38ksi,Yield: 35 ksi
• Finish: Clear or Dark Anodized
• End clamp weight: varies based on height: 0.058 Ibs (26g)
End Clamp Allowable and design loads are valid when components are
Serrated assembled according to authorized UNIRAC documents
Flange Nut Values represent the allowable and design load capacity of a single
end clamp assembly when used with a SolarMount series beam to
retain a module in the direction indicated
• Assemble with one Unirac'/"-20 T-bolt and one '/"-20 ASTM F594
Bea serrated flange nut
Use anti-seize and tighten to 10 ft-Ibs of torque
• Resistance factors and safety factors are determined according to
part 1 section 9 of the 2005 Aluminum Design Manual and third-
Y party test results from an IAS accredited laboratory
Modules must be installed at least 1.5 in from either end of a beam
�-x
L.s Applied Load Average Allowable Safety Design Resistance
Direction Ultimate Load Factor, Loads Factor,
Ibs(N) Ibs(N) FS Ibs(N) 4)
�
H Tension,Y+ 1321 (5876) 529(2352) 2.50 800 (3557) 0.605
ROOM
f"° Transverse, Z± 63(279) 14(61) 4.58 21 (92) 0.330
f
Dimensions specified in inches unless noted Sliding,X± 142 (630) 52(231) 2.72 79(349) 0.555
a
0
. Technical . , , - - ::� UNIRAC
A I-0CTI GROUP COMPANY
SolarMount Beam Connection Hardware
SolarMount L-Foot
Part No. 304000C, 304000D
• L-Foot material: One of the following extruded aluminum alloys: 6005-
{ • 6105-T5, 6
Ult imate tensile: 38ks
i,Yield: 35 ksi
• Finish: Clear or Dark Anodized
J L-Foot weight: varies based on height: —0.215 Ibs(98g)
• Allowable and design loads are valid when components are
Bea assembled with SolarMount series beams according to authorized
Bolt UNIRAC documents
I L-Foot For the beam to L-Foot connection:
•Assemble with one ASTM F593 W-16 hex head screw and one
errated ASTM F594 W serrated flange nut
Flange Nu ' • Use anti-seize and tighten to 30 ft-Ibs of torque
Resistance factors and safety factors are determined according to part
* ' 1 section 9 of the 2005 Aluminum Design Manual and third-party test
Y results from an IAS accredited laboratory
* NOTE: Loads are given for the L-Foot to beam connection only; be
X sure to check load limits for standoff, lag screw, or other
attachment method
a Applied Load Average Safety Design Resistance
3X 50T Direction Ultimate Allowable Load Factor, Load Factor,
��nunvr+ Ibs(N) Ibs(N) FS Ibs(N) 4)
Sliding,Z± 1766(7856) 755(3356) 2.34 1141 (5077) 0.646
Tension,Y+ 1859(8269) 707(3144) 2.63 1069(4755) 0.575
Dimensions specified in inches unless noted Compression,Y- 3258(14492) 1325(5893) 2.46 2004(8913) 0.615
Traverse,X± 486(2162) 213(949) 2.28 323(1436) 0.664
a
0
SOLARMOuNT Technical Datasheets � UNIRAC
A I HLTI GROUP COMPANY
SolarMount Beams
Part No. 310132C, 310132C-B, 310168C, 310168C-B, 310168D
310208C, 310208C-B, 310240C, 310240C-B, 310240D,
410144M, 410168M, 410204M, 410240M
Properties Units SolarMount SolarMount HD
Beam Height in 2.5 3.0
Approximate Weight(per linear ft) plf 0.811 1.271
Total Cross Sectional Area in 0.676 1.059
Section Modulus (X-Axis) in' 0.353 0.898
Section Modulus (Y-Axis) in3 0.113 0.221
Moment of Inertia (X-Axis) in 0.464 1.450
Moment of Inertia (Y-Axis) in 0.044 0.267
Radius of Gyration (X-Axis) in 0.289 1.170
Radius of Gyration (Y-Axis) in 0.254 0.502
f
SLOT FOR T-BOLT OR 1.728
11/" HEX HEAD SCREW SLOT FOR T-BOLT OR
HEX HEAD SCREW
2X SLOT FOR SLOT FOR
BOTTOM CLIP 2.500 BOTTOM CLIP
T 3.000
1.316
SLOT FOR q I —r
3/8" HEX BOLT SLOT FOR 1.385
3�" HEX BOLT- rL77 U
.387
.750
1.207
Y Y 1.875
A A
w X w X
SolarMount Beam SolarMount HD Beam
Dimensions specified in inches unless noted
a