Loading...
HomeMy WebLinkAboutB13-0438 Specifications.pdf B13-0438 ACTIVE ENERGIES SOLAR.. Solar installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-423 3/info @activeenergies.com) Site: Nields Residence 763 Potato Patch Dr. #3 Vail, CO 81657 All AC wiring to be completed by a Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F Panel Arrangement:flush mounted 5 columns of 5 panels oriented in the landscape position, on the east facing roof split around the existing thermal system 11 r, not to scale RECEIVED By David Rhoades at 9:08 am, Oct 02, 2013 Page 1 of 4 9/29/2013 P.O.Box 7627,Avon,CO 81620 1 P: 970.227.0272/303.330.4nO 1 F: 866.403.3485 1 wwwv.wtiveenergies.corn ACTIVE ENERGIES SOLAR.. Calculations 6.25kW System Size (STC) 25 Phono Solar PS250P-20/U solar panels @ 250 watts 25 Enphase M-215 240 micro-inverters—2 branches of 15110 units each Fixed array tilt angle: 18.430 Array azimuth: 120° (where 180°is south) Estimated annual power production: 8,325kWh Maximum PV System Voltage: 690.7 Voc= 37.8V/module 37.8V x 1 module= 37.8V Temperature correction factor 690.7(A) STC =25°C, Temperature Coefficient (Voc) = -0.31%/°K (298°K- 233°k) = 65°K 37.8V+ (-65°K x (-0.31%/°K x 37.8V) x 1 module) 45AV Temperature correction factor Table 690.7 For-40°F use 1.25 37.8V x 1.25 =47.3V Maximum PV Source Circuit(String) Current: 690.8 (A)(1) ISM = 8.7A 8.7A x 1.25 = 10.9A Maximum PV Output Circuit(Array) Current: 690.8 (A)(2) 10.9A x 1 strings = 10.9A Inverter Output Circuit Current: 690.8 (A)(3) .9A @ 240V John Wiles, "Photovoltaic Power Systems and the National Electrical Code: Suggested Practices", 2005,pp. El-E25. Page 2 of 4 9/29/2013 P.O.Box 7627,Avon,CO 81620 1 P: 970.227.0272/303.330.4880 1 F: 866.403.3485 1 wwwv.wtiveenergies.corn ACTIVE ENERGIES SOLAR.. Conductor Sizing Pass Thru Box on Roof to PV Combining Panel (for a 15 panel circuit): Nameplate maximum continuous output current: .9A Maximum Output Power 215 Watts AC 215W-240 V= .9A .9A x 15 inverters = 13.5A per branch 13.5A x 125%= 16.9A #10 THWN-2 or NM-B Table 310.16 40A (90°C column, see note 240.4(D)) Conduit fill adjustment Table 310.15 (13)(2)(a) For 6 current carrying conductors use .70 40A x .70 =28A Temperature correction factor Table 310.16 No Temperature Correction PV Combining Panel to Disconnect to Service Panel (for a 25 micro-inverters): Nameplate maximum continuous output current: .9A Maximum Output Power 215 Watts AC 215W-240 V= .9A .9A x 25 inverters =22.5A per branch 22.5A x 125%=28A #10 THWN-2 or NM-13 Table 310.16 40A (90°C column, see note 240.4(D)) Conduit fill adjustment Table 310.15 (13)(2)(a) No Conduit Fill Adjustment Temperature correction factor Table 310.16 No Temperature Correction Overcurrent Protection Device per circuit PV Combining Panel - 2 x 20A two pole breaker Per Manufacturer Specification Main Service Panel 1 x 30A two pole breaker Page 3 of 4 9/29/2013 P.O.Box 7627,Avon,CO 81620 1 P: 970.227.0272/303.330.4880 1 F: 866.403.3485 1 wwwv.wtiveenergies.corn M VL p� N W N ti � ° �, . 2 -0 Y o m > m p ltJ t N ¢ N N N U L N O U O �'�? I.C) °O O C 'O O m E W d N i M o0 N M T 2i U 7 p > 'p O C O O Z c Y o CD aoc 0Y1 N a � E m o o aw)om o E o o aU E Q cnMoo m W a�(� o _ i o n o 11 11 C VJ . E o C U U C O C p > Vv o a �c- �m Eo � L — 3 o � � Z > cli m XO a ao a o �N a Q n O w .iv aU a5 r m C bo v o�A> ° 22 O ¢U N ED Z N O N N Co clq co N O c o Q c c o c o N c �0 r ° ol Z .y U Y c a V m C O o N O U N Z cc C c c c U O:2 Z - � T O w a W 00 U� M _U O C C C c C M °> El. O o � � FL o Q 00 '>W Z5 _m U Z O rL O O Q O E00 p a_ 00 S $ YO C C5 O U c 'c a� � E Q a m a aria i. zZ L) maa - O C�j CL fn _ ¢ M M7Y o v W~C~.7 JO Co Cl) J C M o N N L M N z O -O '(-a ~ _ CO = N o 0 u c C Q pU ao0 0o �✓ d > U V T QI CO � 00 O U C m 0 3 W Q W O 23 m E¢ �O E N S y m N O =Z O N C 'U °U r �SJ2 CG o y _ m E J m a a0 a Q C.5 U o @ w P, Q � U N _N N g O O C N-. E7 U 0 �� C y U U O m N W m @ ¢ E m a� O m w o H � bQ C� ABOUT PHONO SOLAR Phono Solar Technology Co., Ltd. is one of the world's leading renewable energy product manufacturers and a well _ trusted brand provider. The Phono Solar brand has become synonymous with high performing, top quality photovoltaic -- panels that are ideal for use in large scale power plants, commercial and residential installations. I pill • • 1 1; • gins • • HIGH PERFORMANCE SOLAR ■ ■ ■ ° ■ MODULES - RELIABLY HIGH YIELDS QUALITY ASSURANCE WARRANTIES • High efficiency solar cells together • Durability assured in even the • 10-year product warranty* with high transmission textured glass harshest environments with AMMONIA • 25-year performance warranty* deliver module efficiency of over 16.0%, CORROSION, SALT MIST CORROSION, • Free module recycling through PV leading to minimized installation costs and FIRE TEST certifications. Cycle Association membership** and maximized system output. e Certified to withstand increased snow • High output due to excellent and wind loads of up to 5400Pa. performance in weak-light conditions. • Manufacturing facility certified by ISO • Higher specific yields due to positive 9001, ISO 14001 and OHSAS 18001. power sorting. • Internal quality control with standards • Product quality is assured through the higher than both IEC and UL. use of branded components. aooucr t\ ' PPAa�oP PV CYCLE Clean Energy Coundl * IN COMPLIANCE WITH OUR WARRANTY TERMS AND CONDITIONS. ** IN PV CYCLE MEMBER COUNTRIES ONLY,SEE: WWW.PVCYCLE.COM ONYX . Phon& Solar MECHANICAL CHARACTERISTICS ABSOLUTE MAXIMUM RATING Polycrystalline 156mm x 156mm square, 6 x 10 pieces in series Parameter Values Length: 1640mm(64.6 inch) Operating Temperature From -40 to+85°C Width: 992mm(39.1 inch) Typical Application 20V DC Height:45mm (1.8 inch) Hail Diameter @ 80km/h Up to 25mm 20kg(44.1lbs) Surface Maximum Load Capacity Up to 5400Pa 3.2mm toughened glass Maximum Series Fuse Rating 15A Anodized aluminium alloy IEC Application Class(IEC 61215) A 0.90m wire(o4m.l Fire Rating(UL 1703) C 6 pieces Schottky by-pass diodes 1000V DC(IEC 61215) Maximum System Voltage IP 65 rated 1000V DC(UL 1703) ELECTRICAL TYPICAL VALUESI,2 Model Rated Power(Pmpp) Tolerance Rated Current(Impp) Rated Voltage(V,pp) Short Circuit Current(LO Open Circuit Voltage(V.J I Module Efficiency ft PS235P-20/U 235W 0-+5W 7.94A 29.6V 8.40A 373V 14.44 PS240P-20/U 240W 0-+5W 8.06A 29.8V 8.50A 37.5V 14.75 PS245P-20/U 245W 0-+5W 8.184 30.OV 8.60A 37.7V 15.06 PS250P-20/U 250W 0--+5W 8.30A 30.2V 8.70A 37.8V 15.37 PS255P-20/U 255W 0-+5W 8.42A 30.4V 8.80A 37.9V 15.67 PS260P-20/U 260W 0-+5W 8.53A 30.6V 8.90A 38.OV 15.98 PS265P-20/U 265W 0--+5W 8.61A 30.8V 9.004 38.1V 16.29 DIMENSIONS TEMPERATURE CHARACTERISTICS NOCT(Nominal Operation Cell Temperature)860133.861 1360153.54) Voltage Temperature Coefficient E45C± Current Temperature •.- e Section A-A WEAK LIGHT PERFORMANCE i s u 900(35.43) 1110.43) 1000 1 1 800 0.8 0.996 45(1.77) 600 0.6 0.99 frame(block) 400 0.4 0.983 L 1 200 0.2 0.952 100 1 0.1 1 0.921 35(1.38) PACKING CONFIGURATION 40'HQ Pieces per pallet 22 Pallets per container 28 1640(64.57) Note:mm(inch) 616 PARTNER INFORMATION Note: This datasheet summarises product warranty and specifications, which are subject to change without notice. The exact module specification will be subject to the description in the sales contract. Further information can be found on our website: www.phonosolar.com 1.Defined as standard deviation of thousands measurements.Absolute power values depend on the measuring system.They can differ by+/-5%from one measuring system to another. 2. Measurement conditions under irradiance level of Standard Test Condi lons(STC): 1000W/m', Air mass 1.5 Spectrum,cell temperature of 25°C. www.phonosolar.com EN-U-P-BB-1210 re] ENPHASE MICROINVERTER M215 .� [e] enphae E N E R G Y The Enphase Energy Microinverter System improves energy harvest, increases reliability, and dramatically simplifies design, installation and management of solar power systems. The Enphase System includes the le U fd I I I IIU UII IVCI LUI, tI r--.Iy CUII IIII I IIUI IL c1LIUI lJ VcUWy, al IU EI IIJy l ILUI 1I, Enphase's monitoring and analysis software. - Maximum energy production P R o D u c T I v E - Resilient to dust, debris and shading - Performance monitoring per module - System availability greater than 99.8% R E i A a E - No single point of system failure SMART - Quick & simple design, installation and management - 24/7 monitoring and analysis S A F E - Low voltage DC - Reduced fire risk cl �s c MICROINVERTER TECHNICAL DATA Input Data (DQ M215-60-2LL-S22623 M215-60-2LL-S22-NA/S23-NA(Ontario) Recommended maximum input power(STC) 260W Maximum input DC voltage 45V Peak power tracking range 22V—36V Operating range 16V—36V Min./Max.start voltage 26.4W45V Max. DC short circuit current 15A Max. input current 10.5A Output Data (AQ @208 Vac @240 Vac Maximum output power 215W 215W Nominal output current 1.0 A* 0.9 A* Nominal voltage/range 208W1 83V-229V 240W21 1 V-264V Extended voltage/range 208W1 79V-232V 240W206V-269V Nominal frequency/range 60.0/59.3-60.5 60.0/59.3-60.5 Extended frequency/range 60.0/59.2-60.6 60.0/59.2-60.6 Power factor >0.95 >0.95 Maximum units per 20A branch circuit 25(three phase) 17(single phase) Maximum output fault current 1.05 Arms,over 3 cycles;25.2 Apeak, 1.74ms duration *Arms at nominal voltage Efficiency CEC weighted efficiency 96.0% Peak inverter efficiency 96.3% Static MPPT efficiency(weighted, reference EN 50530) 99.6% Dynamic MPPT efficiency(fast irradiation changes, reference EN 50530) 99.3% Night time power consumption 46mW Mechanical Data Ambient temperature range -40°C to+65°C Operating temperature range(internal) -40°C to+85°C Dimensions(WxHxD) 17.3 cm x 16.4 cm x 2.5 cm(6.8" x 6.45"x 1.0")* Weight 1.6 kg (3.5 Ibs) Cooling Natural convection—no fans Enclosure environmental rating Outdoor—NEMA 6 without mounting bracket Features Compatibility Pairs with most 60-cell PV modules Communication Power line Warranty 25-year limited warranty Compliance UL1741/IEEE1547, FCC Part 15 Class B CAN/CSA-C22.2 NO.0-M91,0.4-04,and 107.1-01 Enphase Energy, Inc. 06/13/2011 201 1St Street, Petaluma, CA 94952 877 797 4743 www.enphase.com ®Printed on 100 percent recycled paper. Tall Catalog 2009 Flashing Assembly ZiIIaTM Flashing is superior to all comparable products on the market, and can be used with any available standoff and or mounting components. The longevity of this product is outstanding, outlasting the roof and the solar system simply due to innovative engineering that protects all of the degradable components. The ZillaTM Flashing Assembly is sold in a 4 piece component set. This assembly includes:double stud bolt,silicone washer, flashing and base plate.Pieces may be purchased separately upon request. ZiIIaTM Flashing Components Product Product Number Description Materials Size Weight Color #Per Package Double Stud Assembly Threaded double stud bolt& a high temperature silicone washer that is encapsulated Zinc plated in a compression zone to steel and a high 3/8"—16 Threads DS-ZP eliminate water infiltration 0.170 lb. Silver 25 makes up the double stud, temperature 1.5"w x 5/8"tall x 2 assembly.With no exposed silicone washer parts to degrade,it is designed to outlast the solar system. FLSH-CC Custom 0.640 lb. Custom FLSH-CU Copper 1.37 lb. I Copper FLSH-SS Stainless Steel 0.640 lb. Silver FLSH-SSBLK Sits on top of the base plate, Stainless Steel 0.640 lb. Black Flashing FLSH-GS and is attached with the Galvanized Steel 8"w x 10"t 0.640 lb. Silver 6 double stud assembly. FLSH-GSBLK Galvanized Steel 0.640 lb. Black FLSH-AL Aluminum 0.274 lb. Silver FLSH-ALBLK Aluminum 0.274 lb. I Black BP-AL Aluminum 0.179 lb. Base plate is attached to the roof with lag bolts.Flashing Base Plate _ BP-SS is attached to the base Stainless Steel 3"w x 3 7/8"t 0.418 lb. Silver 6 plate using the double stud assembly. BP-GS Galvanized Steel 0.418 lb. ZiIIaTM Flashing Assembly Product Product Number Description Materials #Per Package Flashing Base Plate Double Stud FLSH-CC BP-AL FLSH-CU DS-ZP FLSH-SS FLSH-SSBLK BP-SS All four pieces of the ZiIIaTM'Flashing Assembly includes the double stud, See above 6 FLSH-GS washer,flashing and base plate for materials list FLSH-GSBLK FLSH-AL BP-GS DS-SS FLSH-ALBLK 3 0 SOLARMOUM Technical . . . - - ::� UNIRAC A I-0CTI GROUP COMPANY SolarMount Technical Datasheet Pub 110818-ltd V1.0 August 2011 SolarMount Module Connection Hardware.................................................................. 1 BottomUp Module Clip.................................................................................................1 MidClamp ....................................................................................................................2 EndClamp....................................................................................................................2 SolarMount Beam Connection Hardware......................................................................3 L-Foot...........................................................................................................................3 SolarMountBeams..........................................................................................................4 SolarMount Module Connection Hardware SolarMount Bottom Up Module Clip Part No. 302000C Washer Bottom Up Clip material: One of the following extruded aluminum Bottom Nut (hidden..see alloys: 6005-T5, 6105-T5, 6061-T6 t up Clip note*) Ultimate tensile: 38ksi,Yield: 35 ksi • Finish: Clear Anodized • Bottom Up Clip weight: -0.031 Ibs (14g) Beam Bolt Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized UNIRAC documents • Assemble with one'/4"-20ASTM F593 bolt, one '/"-20ASTM F594 serrated flange nut, and one 1/4"flat washer 'X Use anti-seize and tighten to 10 ft-Ibs of torque Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- _ _ party test results from an IAS accredited laboratory Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Load Factor, FRIP 0 Ibs(N) Ibs (N) FS Ibs(N) CD Tension,Y+ 1566(6967) 686(3052) 2.28 1038(4615) 0.662 t Y Transverse,X± 1128(5019) 329(1463) 3.43 497(2213) 0.441 i R10 X Sliding, Z± 66(292) 1 27(119) 2.44 41 (181) 0.619 Dimensions specified in inches unless noted a 0 UNIRAC . - , . , , - - ::e A I HLTI GROUP COMPANY SolarMount Mid Clamp Part No.302101 C,302101 D,302103C,302104D, 302105D,302106D • Mid clamp material: One of the following extruded aluminum Mid 5 4 Fla rr N Bolt alloys: 6005-T5, 6105-T5, 6061-T6 e u Clamp '' .._ Ultimate tensile: 38ksi,Yield: 35 ksi Finish: Clear or Dark Anodized l Mid clamp weight: 0.050 Ibs (23g) Allowable and design loads are valid when components are `-ems assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac'/4"-20 T-bolt and one '/"-20 ASTM F594 serrated flange nut ., Use anti-seize and tighten to 10 ft-Ibs of torque Beam Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- party test results from an IAS accredited laboratory Applied Load Average Allowable Safety Design Resistance 3.00 D«? - Direction Ultimate Load Factor, Load Factor, BE WiEEN MQUULES Ibs(N) Ibs(N) FS Ibs(N) Tension,Y+ 2020(8987) 891 (3963) 2.27 1348(5994) 0.667 Transverse,Z± 520 (2313) 229(1017) 2.27 346(1539) 0.665 * Sliding, X± 1194(5312) 490(2179) 2.44 741 (3295) 0.620 ■X Dimensions specified in inches unless noted SolarMount End Clamp Part No.302001C,302002C,302002D,302003C, 302003D,302004C,302004D,302005C,302005D, 302006C,302006D,302007D,302008C,302008D, 302009C,302009D,302010C,302011C,302012C End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 Bolt Ultimate tensile: 38ksi,Yield: 35 ksi • Finish: Clear or Dark Anodized • End clamp weight: varies based on height: 0.058 Ibs (26g) End Clamp Allowable and design loads are valid when components are Serrated assembled according to authorized UNIRAC documents Flange Nut Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble with one Unirac'/"-20 T-bolt and one '/"-20 ASTM F594 Bea serrated flange nut Use anti-seize and tighten to 10 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- Y party test results from an IAS accredited laboratory Modules must be installed at least 1.5 in from either end of a beam �-x L.s Applied Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Loads Factor, Ibs(N) Ibs(N) FS Ibs(N) 4) � H Tension,Y+ 1321 (5876) 529(2352) 2.50 800 (3557) 0.605 ROOM f"° Transverse, Z± 63(279) 14(61) 4.58 21 (92) 0.330 f Dimensions specified in inches unless noted Sliding,X± 142 (630) 52(231) 2.72 79(349) 0.555 a 0 . Technical . , , - - ::� UNIRAC A I-0CTI GROUP COMPANY SolarMount Beam Connection Hardware SolarMount L-Foot Part No. 304000C, 304000D • L-Foot material: One of the following extruded aluminum alloys: 6005- { • 6105-T5, 6 Ult imate tensile: 38ks i,Yield: 35 ksi • Finish: Clear or Dark Anodized J L-Foot weight: varies based on height: —0.215 Ibs(98g) • Allowable and design loads are valid when components are Bea assembled with SolarMount series beams according to authorized Bolt UNIRAC documents I L-Foot For the beam to L-Foot connection: •Assemble with one ASTM F593 W-16 hex head screw and one errated ASTM F594 W serrated flange nut Flange Nu ' • Use anti-seize and tighten to 30 ft-Ibs of torque Resistance factors and safety factors are determined according to part * ' 1 section 9 of the 2005 Aluminum Design Manual and third-party test Y results from an IAS accredited laboratory * NOTE: Loads are given for the L-Foot to beam connection only; be X sure to check load limits for standoff, lag screw, or other attachment method a Applied Load Average Safety Design Resistance 3X 50T Direction Ultimate Allowable Load Factor, Load Factor, ��nunvr+ Ibs(N) Ibs(N) FS Ibs(N) 4) Sliding,Z± 1766(7856) 755(3356) 2.34 1141 (5077) 0.646 Tension,Y+ 1859(8269) 707(3144) 2.63 1069(4755) 0.575 Dimensions specified in inches unless noted Compression,Y- 3258(14492) 1325(5893) 2.46 2004(8913) 0.615 Traverse,X± 486(2162) 213(949) 2.28 323(1436) 0.664 a 0 SOLARMOuNT Technical Datasheets � UNIRAC A I HLTI GROUP COMPANY SolarMount Beams Part No. 310132C, 310132C-B, 310168C, 310168C-B, 310168D 310208C, 310208C-B, 310240C, 310240C-B, 310240D, 410144M, 410168M, 410204M, 410240M Properties Units SolarMount SolarMount HD Beam Height in 2.5 3.0 Approximate Weight(per linear ft) plf 0.811 1.271 Total Cross Sectional Area in 0.676 1.059 Section Modulus (X-Axis) in' 0.353 0.898 Section Modulus (Y-Axis) in3 0.113 0.221 Moment of Inertia (X-Axis) in 0.464 1.450 Moment of Inertia (Y-Axis) in 0.044 0.267 Radius of Gyration (X-Axis) in 0.289 1.170 Radius of Gyration (Y-Axis) in 0.254 0.502 f SLOT FOR T-BOLT OR 1.728 11/" HEX HEAD SCREW SLOT FOR T-BOLT OR HEX HEAD SCREW 2X SLOT FOR SLOT FOR BOTTOM CLIP 2.500 BOTTOM CLIP T 3.000 1.316 SLOT FOR q I —r 3/8" HEX BOLT SLOT FOR 1.385 3�" HEX BOLT- rL77 U .387 .750 1.207 Y Y 1.875 A A w X w X SolarMount Beam SolarMount HD Beam Dimensions specified in inches unless noted a