Loading...
HomeMy WebLinkAboutB13-0370 PLANS APPROVED ISSUE RECORD 08/02/13 S TA N DA R D A B B R E V I AT I O N S PERMIT SUBMITTAL Reviewed for Code Compliance ; Code: 2012 International Building Code (IBC) ABV ABOVE EIEV ELEVATOR LIN LINEN RS ROUGHSAWN T�WN DF VAIL�� � By J Mondragon at 8:48 am, Sep 19, 2013 approved per WC ACOUS ACCOUSTICAL EM EMERGENCY OUTLET LKR LOCKER RWC RAIN WATER CONDUCTOR ACT ACCOUSTICALCEILINGTILE EMER EMERGENCY LLH LONGLEGHORIZONTAL A�D ADDENDUM ENG ENGINEER LLV LONGLEG VERTICAL S SOUTH ADJ ADJUSTABLE EOS EDGE OF SLAB LT LIGHT SC SOLID CORE A D M I N I T RAT I V E I N F O ■ AFF ABOVE FINISHED FLOOR EQ EQUAL LTL LINTEL SCD SEAT COVER DISPENSER � AFG ABOVEFINISHEDGRADE EQUIP EQUIPMENT LTWT LIGHTWEIGHT SCHED SCHEDULE AG AGGREGATE EXIST EXISTING LVR LOUVER SD SOAP DISPENSER AL ALUMINUM EXP EXPANSION SECT SECTION ALT ALTERNATE EXT EXTERIOR M MASTER SF SQUAREFEET ANCH ANCHOR MACH MACHINE SGLT STRUCTURALGLU-LAMTIMBER APSROX qSPHA�LTMATELY FBO FURNENURE'BVOWNER MAT MATEORAL SHRVS SHOWER LEGAL DESCRIPTION OF PROPERTY: ARCH ARCHITECTURAL FD FLOORDRAIN MAX MAXIMUM SHT SHEET ASI ARCHITECT'SSUPPLEMENTAL FDN FOUNDATION MECH MECHANICAL SHTG SHEATH�N� - SUBDIVISION: BRIDGE STREET BUILDING CONDOMINIUMS INSTRUCTIONS FE FIRE EXTINGUISHER MEP MECHANICAL,ELECTRICAL and SIM SIMILAR � - ATTEN ATTENUATION FEC FIREEXTINGUISHERCABINET PLUMBING SPEC SPECIFICATION(S) � UNIT. C'� AUTO AUTOMATIC FFE FINISHFLOORELEVATION MFGR MANUFACTURER SQ SQ�ARE �� � � ' � PARCEL NUMBER: 2102-082-95-003 FFL FINISHED FLOOR LINE MH MAN HOLE SR SINK RECEPTACLE � � � BD BOARD FHC FIRE HOSE CABINET MIN MINIMUM SS STAINLESS STEEL - BDRM BEDROOM FIN FINISH(ED) MIR MIRROR SSK SERVICE SINK ' � BEL BELOW FIX FIXTURE MISC MISCELL4NEOU5 SST STAINLESS STEEL � - _� BET BETWEEN FLG FLASHING MMB MEMBRANE ST STAIN -� � � - — BKT BRACKET FLR FLOOR(ING) MO MASONRVOPENING STA STATION - -- � BLOG BUILDING FLUOR FLUORESCENT MTD MOUNTED STD STANDARD � � 8LK BLOCK FPHB FREEZE PROOFHOSEBIB MTL METAL STL STEEL - �� � BLR BOILER FR FIRE RESISTIVE MUL MULLION STO STORAGE _ �- � BM BEAM FREZ FREEZER MW MICROWAVE STRUCT STRUCTUREorSTRUCTURAL / - - - , ; - '� BO BYOWNER FRM FRAME SUSP SUSPEN�(ED) ' - � ' BOF BV OWNER,FUTURE FRP FIBERGLASS REINFORCED (N) NEW SV SHEET VINVL - � BOT BOTTOM PANEL(ING) N NORTH SVM SVMMETRICAL � - - - , � - BOW BOTTOM OF WALL FRT FIRE RETARDANT TREATED NIC NOT IN CONTRACT SYS SYSTEM \\ - _ � BRG BEARNING FT FEET NO NUMBER � U I L D I N G C O D E S U M M A RY BSMT BASEMENT FTG FOOTING NOM NOMINAL 7 TREADS - � � _ FURR FURRING NTS NOTTOSCALE T&8 TOPANDBOTTOM - � CAB CABINET FUT FUTURE T&G TONGUEAND GROOVE � - � � � CAN CABLE TELEVISION FV FIELD VERIFY OA OVERALL 7g TOWEL BAR '- CB CATCH BASIN OC ON CENTER TEL TELEPHONE - _� � - _ � , � � CCD CONSTRUCTIONCHANGE GA GAUGE OD OUTSIDEDIAMETER THK THICKorTHICKNESS ` - - _ � - DIRECTNE GALV GLAVANIZED OFF OFFICE THR THRESHOLD ` � - ,� CCN CLOSEDCIRCUITTELEVISION GB GR4BBAR OH OPPOSITEHAND THRU THROUGH � � �� BUILDING CODE: 2012 IBC / � i� � � CEM CEMENT GCMU GLAZEDCONCRETE MASONRY OPG OPENING TO TOPOF - � CER CERAMIC UNIT(S) ppp OPPOSITE TOC TOP OF CONCRETE � _ _ � �� CFL COUNTERFLASHING GD GR4DE OTO OUTSIDE-TO-OUTSIDE TOV TOWN OF VAIL � CG CORNERGUARD GEN GENERAI 70W TOPOFWALL �� \ \ CONSTRUCTION TYPE. V-A CIP CAST IN PLACE GFP GAS FIRE PLACE pqC PREVIOUSLYAWARDEO 7pH TOILET PAPER HOLDER � � - - - / �� � CJ CONTROL JOINT GI 6AlVINIZED IRON CONTRACT TPTN TOILET PARTITION � CK CAULK(ING) GL GLASS PARTN PARTITION / \ \ CL CENTERLINE GND GROUND PFB PREFABRICATED TV TELEVISION CLG CEILING GRT GROUT PH PHONE TYP TYPICAL - \� �� � DWELLING UNITS: 3 TOTAL, 1 NEW CLL CONTRACT LIMIT LINE GYP GYPSUM WALL BOARD PL PLATE UL UNDERWRITER'S LABOR4TORY � \\ CLOS CLOSET PLAM PLASTIC LAMINATE UNF UNFINISHE� _ I� ' '�\ CLR CLEARANCE HB HOSE818 PLAS PLASTER UON UNLESSOTHERWISENOTED - - - - � TOTAL SQUARE FOOTAGE. Z4OH SQ. FT. ;� . '-____-'-" . .... CMU CONCRETE MASONRYUNIT HC HOLLOW CORE PLNK PLANK ---==-, - - CNTR COUNTER HD HEA� PLWD PLVWOOD UOS UNLESS OTHERWISE SPECIFIED -_------- CO CLEAN OUT HDCP HANDICAP(PED) PNL PANEL UR URINAL � -- COL COWMN HORL HANDRAIL PNT PAINT � CON CONCRETE HDW HARDWARE PNTD PAINTED V VACWM - 1 - - BUIDLING HEIGHT ALLOWED: 35'-0" � VB VAPOR BARRIER I _- ' -- _ � ' - _ ' ��� __ _�- I CONN CONNECTION HDWD HAROWOOD PORC PORCELAIN -_ - - � � - VCP VITRIFIED CLAV PIPE _____- - I - � CONST CONSTRUCTION HM HOLLOW METAL PR PROPOSAL REQUEST VCT VINVL COMPOSITION TILE -' - - �� O CONT CONTINUOUS HORIZ HORIZONTAL PR PAIR - ��-- - - . � � � — _ I I CONTR CONTRACT(OR) HR HOUR PROJ PROJECT VERT �ERT��A� _ - _ �� - BUILDING HEIGHT PROPOSED. 35-0 VEST VESTIBULE _ _ ' �� - -__ _--- ��ii -= � CORR CORRIDOR HT HEIGHT PSF POUNDSPERSQUAREFOOT VIN VINVL ' � _ � - � __ . ,---�_ - � CPT CARPET HTR HEATER P51 POUNDS PER SQUARE INCH VTR VENT TO ROOF �`' - -- -�--- - CT CERAMIC TILE HVAC HEATING,VENTILATION and AIR PTD PAPER TOWEL �ryC VINYL WALL COVERING - I�� - �- CONDITIONING DISPENSER/RECEPTACLE - = - CTR CENTER —„_ - - � - - , CTSK COUNTERSINK PV PAVEMENT --_I- -� _ _ - _ - - - - � IBC INTERNATIONAL BUILDING CODE W WASHER =_ � _ _ - - D DRVER orINSTALLEDBYCONTRACTOR pT QUARRYTILE W� WITH � - - - . DBL DOUBLE ID INSI�E�IAMETER W�O WITHOUT �_� - _ _ _ _ - - _ - � DEPT DEPARTMENT IN INCH R RISERS WATER-RES WATERRESISTANT �I - _ - - = - ��.L.�: INFO INFORMATION RA� RADIUS WB WASTEBASKET l_ - - - - - DET DETAIL INSUL INSULATION ar INSULATED RD ROOF DRAIN WC WATER CLOSET � - - - - - - , DF DRINKING FOUNTAIN WD WOOD ---�� � __ _ ' INT INTERIOR - - - F R rR F R N E - , RE RE E TO o E E E C k - DIA DIAMETER - _ - _ DIAG DIAGONAL INTX INTERSECTION REC RECESS(ED) WF WIDE FLANGE -I-T - _ - - - - - - _ _ _ - � DIM DIMENSION INV INVERT REF REFRIGERATOROrREFRIGERATED WIN WINDOW '-i - - - - _ _ _ WP WATERPROOF(ING) - - - - - DN DOWN REINF REINFORCED - - _ ' - PT NT - I��.I��� . DR DRAIN �AN JANITOR REQ'D REQUIRED W WORKINGPOI - - _ - , _ - DS DOWNSPOUT �B JUNCTIONBOX WSCT WAINSCOT _ _ � � _ - I _ RES RESISTANT ' � DW DISHWASHER �T JOINT RESIL RESILIENT �F WELDED WIRE FABRIC � = � � __ - � ._ � - � � � �� � �ryI1 � DWG DRAWING RET RETAINING 'I � DWR DRAWER K.D. KNOCKDOWN REV REVISE,REVISEDOrREVISION .-_------- - - - _ �I �� II,„ � � � K.O. KNOCKOUT RF RESILIENT FLOORING . _ - - i ��� � �II�i I � � � E EAST KIT KITCHEN RFG ROOFlNG I I I - - _ - _ - _ _ I I� � � EA EACH KPL KICK P�ATE RFL REFLECTED - - - ' � - ' I �' W � EH EXHAUST FAN RL RAIN LEA�ER -- - i i '� W /y� _ _ KJ LAB LABORATORV - I EJ EXPANSION JOINT RM ROOM _ A' _ _ _ _ _ ' r EL ELEVATION LAM LAMINATE RO ROUGH OPENING � � - O L.� LAV LAVATORY - _ ��� ELECT ELECTRICAL ROD ROOF OVERFLOW DRAIN - - LBL LABEL _ - - . I J : . . _ _ _ - — - I . II I i I II i L O � _ _ - _ I - _ - _ - . , , ; � � � � r � - _ - -� - _ _ -- - � P ROJ E CT D I R E CTO RY w � � M ISC . ABBREVIATIONS - - - -��=� - _ _ __ - - z o o ., O J o a` _ _ I - _ - _- 4 OWNER'S REPRESENTATIVE: BRIDGE STREET BUILDING, LLC � O a � ROUND _�� _ - _ _ _ � �� � � _ _—� 280 COLUMBINE STREE, SUITE 209 W/ WITH _�� iI i = �, � �-, - _ - - __ �/ '�� DENVER, CO80206-4718 � � DEGREES - I- a�- � ;,-- _ , - - e e '�(` � OO J ± PLUS OR MINUS - - - _ - � PROPERTY LINE - ' ' I � �r� ,� ��'�- � `-��-- - - - _ ,� ,, � '. � DO � '� � N i �� < ANGLE , - - _ �� I- � _ _ �� — _ _ - - li /. ;i \ � CENTER LINE j�- _ _ — -��—� - _ _ _ � / "' I� -1�' � i �°__ _ _ �� - �- _ _ _ � �� � ARCHITECT: BILL PIERCE, PRINCIPAL IN CHARGE - i_ i - - - i� _ - _ -7 � I � - � - - � �,� PIERCE ARCHITECTS �-� - I�� - ` ° - == - - — — —, � _ _ _ - 1650 E.VAIL VALLEY DRIVE, C1 � �� - �' �- - _ �_ ` - _ _ _ _- VAIL, COLORADO 81657 - - - ��� - - � �I r- - i' D RAW I N G C O N�/E N T I O N S �-�,�- - ---_�, --_�= --� _ �_�, - _ - _ , �� P: 9�0.4�6.634z , _ _ � F: 970.476.4901 --�_ _ - - _ _ - __- _ _ _ ; � N � - � _ I� E: BILL@VAILARCHITECTS.COM ��_ � � � � � T�--�—r_= r=-a �� � n �_�-_ �-, -_ 1�;` ��� � ,%� i� ,,i DETAIL DESIGNATOR � �, � "--- � ���� �I�� � �-_ �_�' � --�- CONTRACTOR: MARK HALLENBECK � 101 DOOR DESIGNATOR 1 i WALL TYPE � ��, SIM ROCKY MOUNTAIN CONSTRUCTION GROUP 1 DETAIL NUMBER � P: 1-970-476-4458 A101 SHEET WHERE H WN 1 i WINDOW DESIGNATOR M: 1-719-499-9248 E: markh@rockymountainconstructiongroup.com BUILDING SECTION DESIGNATOR �� REFERENCE ( O STRUCTURAL ENGINEER: N/A SIM " N/A � SECTION LETTER A A101 SHEET WHERE SHOWN Room name P:: N/A t�� �;�� � SHEET INDEX F: N/A ���,�r 101 HEET ]� DE\ RIPTI N BY I\\I �E DATE E: N�A ` � �'� � 100'-0" S I I V� O V V V jl LEVEL INDICATOR IA0.00 COVER SHEET PA 08/02/13 MECHANICAL ENGINEER: MARTIN ZOUREK '' REVISED AREA AEC \Y�� /� . 1 � A0.01 ADA COMPLIANCE PA 08/02/13 OF DRAWING � PO BOX 8489 AVON, CO �* ADDENDUM �-`- �A0.02 EXITING DIAGRAM PA i08/02/13 � � � �^ � / A2.01 DEMOLITION PLAN PA 08/02/13 P: 1-970-748-8520 r��,�, ��G � 100'-0" F; /�/ `,�, SPOT ELEVATION �A2.02 2ND FLOOR PLAN PA 08/02/13 � �` A2.03 RCP PA 08/02/13 E: martin@aec-vail.com A6.01 INTERIOR ELEVATIONS PA 08/02/13 �A6.02 INTERIOR ELEVATIONS PA 08/02/13 INTERIOR DESIGN: N/A A6.03 INTERIOR ELEVATIONS PA 08/02/13 N/A M AT E R I A L SY M B O L S �A6.04 INTERIOR PERSPECTIVES Author 08/02/13 N/A IA9.01 DOOR SCHEDULE PA 08/02/13 P: N/A F: N/A r"".— � . .. „ . ID.01 FLOOR PLAN ID 08/02/13 E: N/A d. f I D.02 RC P I D 08/02/13 r ' � ' � ' ID.03 FINISH PLAN ID 08/02/13 LANDSCAPE ARCHITECT: N/A � N/A ' � � , � � , � ID.04 CEILING FINISH PLAN ID I08/02/13 N/A ?- ' � � � � � � � ID.05 FFA PLAN ID 08/02/13 �;� � COMPACTED STONE PAVERS DIMENSIONAL P: N/A � BACKFILL LUMBER ��ID.06 ID LEGEND&SCHEDULE ID 08/02/13 ,r � _,_ . F: N/A ;, �a..�-,.�•,�.:� , s , , � , -.�� , ��� � ��,t-�-� �-� .r.�w , 4 � , s � , 4 � ` � IM1.0 MECH. SPECS, LEGEND, SCHEDULES& DETAILS AEC 08/02/13 E:. N/A � � , � , � �� � ��� � �M1.1 MECH 2ND FLOOR PLAN HVAC AEC 08/02/13 � � ��'� � LIGHTING DESIGN: N/A M2.0 MECH 1ST FLOOR CEILING PLAN HVAC AEC 08/02/13 BRICK VENEER CMU WOOD M2.1 MECH 2ND FLOOR PLAN HVAC AEC 08/02/13 N/A N/A d / E1.0 ELECTRICAL SPECS, LEGEND, SCHEDULES& DETAILS AEC 08/02/13 P: N/A aa ^d //, �E2.0 2ND LEVEL POWER&SYSTEMS PLAN AEC 08/02/13 F: N/A C.I.P. CONCRETE STEEL NEW STUD �E3.0 2ND LEVEL LIGHTING PLAN AEC 08/02/13 E: N/A WALL 1650 Fallridge Road, Suite C-1 �P1.0 PLUMBING SPECS, LEGEND, SCHEDULES&DETAILS AEC �08/02/13 Vail, Colorado 81657 I P2.0 2ND FLOOR DHW&GAS PLAN AEC 08/02/13 f.(970)476-4901 p.(970)476-6342 P2.1 2ND FLOOR SANITARY WASTE &VENT PLAN AEC 08/02/13 BATT INSULATION RIGID INSULATION EXISTING STUDWALL RECEIVED VER HEET �ate: 09 / 05 / 2013 Ti��N �]F '��l� By: STONE VENEER CONCRETE TOPPING GROUND LINE D . RHOADE S A0 . 00 Reviewed for Code Compliance 39�`"° M��oR LEVERVALVE � ISSUE RECORD � Code: 2012 International Building Code (IBC) e°maX 36,,m,� 54��m;n. � � � ���� ��W� �,� �Jal� By J Mondragon at 8:48 am, Sep 19, 2013 = — P���PIPWG = � � � �z" 42"m�°. � °� _ 08/02/13 � , - � �z^ mm _ ncc�e�r�ou� M PULL SIDE PUSH SIDE � E PERMIT SUBMITTAL ° ° X �O PE = Y:X `( � -� ADJOINING SLOPESHALL Y WHERE X IS A x � Tp. �� clear NOTDCC� 1:20 LEVELPLANE � _ _ c c = floor � E space i .� E �O E E � i� \ ;; \�\\��\\��\ ��\\�,�\\'�,\\��\\�\ �\ ��--- \ � TOILET - 30"min. WALK `� ,A� �V��' .�� V���A�A�.A� �� � _ � _� - � � - �' � -�_� � � �\ � \\\\\�\ \ \\ \,.A \ ' . A\\\ �:�,, � � , _ � RG. 11 (ADA) �T ° �� E � � �' �� RG. 32 (ADA) 96" min 60" min MEASURE7�/IENTOFCURBRAMPSLOPE � �, �$„ 24"preferred � ,s° mm. a° °max. CLEARROORSPACEATLAVATORIES knee clearance toe 96" min.for NS � clearance � (a) back wall (b) side wall „��mm. dePm 21'-0" min (ADA) - 4.22Toilet Rooms. � \ RG. 9 (ADA) F1G. 29 (ADA) F1G. 31 (ADA) 4.22.3 Clear Roor�ace. FIG. 502.2 & 502.3 (ANSI) GRAB BARSATWAIFJ�CLOSEfS LAVATORIESCLEARANCE 1he accessible fixturesand controls DIMENSION OFPARKING SPACES HOPoZONTALPROJECl10N ORRUN NOlE:X= 12°if � (ANSI A117.1-2003 FIG. 604.5.1 & required in 4.22.4, 4.22.5, 4.22.6, and ��d - doorhasboth \ 604.5.2) LANDING n � closerand latch 4.22.7 shall be on an accessible route. ��a ��� az°mm. ,a° An unobstructed turning space complying �� � � � �NpiN� �a� -� ��� with 4.2.3 shall be provided within an FrontApproach - 9,vinging �_ accessible toilet room. lYie clearfloor i 20'-0" min /�� �oo� � space at fixturesand controls, the �� I ( accessible route, and the turning o� �;'�-;;;;,,;=,�;'��;;'=, Max wsE nnax. Howz PFZO�EC�oN space mayoverlap. � �OPE (INCHES) (FEET) PULL SIDE PUSH SIDE ;�;%;;;;'�i%=;;;,;;;; — 1:12 TO <1:16 30 I = � 30 1:16 70 <1:20 30 54 min � � ¢o (ADA) - 4.18 Urinals. RG. 16 (ADA) � � RG. 10 (ADA) COMPONENl50FA SINGLERAMPRUN �� clearfloorspace 4.18.1 General. FIG. 503.3 (ANSI) AND SqMPLERAMP DIMENSIONS Accessible urinalsshall comply with 4.18. ACCESSAISLEATPASSEIVGER -��� > LOADWG ZONES �, X = � �� � 4.18�2 Height. � � � Urinalsshall be stall-type 6o°m��. orwall-hung with an elongated rim at a � x maximum of 17"(430mm) above the finish O (ADA) -4.7.7 Detectable Warnings. � floor. � A curb ramp shall have a detectable warning complying RG. 28 (ADA) � with 4.29.2. 7he detectable warnin shall extend the full CLEARFLOORSPACEATWA7ERCLOSEfS 9 4.18.3 Clear Roor�ace. width and depth ofthe curb ramp. \ A clearfloorspace 30"x48"(760mm x � NOlE:X=36"min. lf Y=60" NOlE:Y=48"min. � 1220mm) shall be provided in front of X=42"min. lf Y=54" ifdoorhasboth closerand latch � urinalsto allow forward approach. lYiis � \ clearspace shall adjoin oroverlap an � n°-,s° I ,r�.,s° accessible route and shall comply with � �b� ��_ - - Hinge 9de Approach - 9,vinging � l 4.2.4. Urinal shieldsthat do not extend � planting or �oo�s beyond the front edge of the urinal rim � (fl � other � may be provided with 29"(735mm) z w � �� � non-waikinq � j clearance between them. � `` su rfa c e x � �� E ' � LL � flared side PULL SIDE PUSH SIDE � a - � ��(� � � E � � r O M 36 LyP 24" min. � � � � � � M , � �N� �.2s°- .5° 15„ (ADA) -4.19.6Mirrors. Q � � A za"mlo. �� �\���, ' ' Mirrorsshall be mounted with bottom edge �J,J �k '� �� � „ aa° �n. ofthe reflecting surface no higherthan 40" � j 8"min. 6 max . � — O � � 1015mm above the finish floor see F . 31 . � .� I � ) � J ) � 10 � _` equipment za^max J a If X islessthan 48" b RG. 13 ADA � � permitted in O � Or , then the slope of �a� � � � � � } �\ � _ } shaded area F1G. 39 (e) (ADA) � v retumed = E BUILT- UP C URB RAM P the flared sde \ flared = GRAB BAR � curb � � � shall not exceed side � (a) (b) � � J 1:12 � �outHeight ClearFloor N � (ADA) -4.7.11 Islands. � CI arance �ace �2°m��. 36°m��. �z°m��. � \ Any raised islandsin crossingsshall be cut through - - - - � RG. 12 (ADA) level with the street or have curb rampsat both sides � � � � � SIDESOFCURB RAMPS and a level area at least 48"(1220mm) long between notto � � the curb rampsin the part of the island intersected by � exceed � � NOlE:Y=54"min. NOlE:Y=48"min. fountain � � the CI'OSSI1lgS. ifdoorhascloser. ifdoorhascloser. \�� depth ' 3� 30"m in � ��� � � � Latch Sde Approach - 9✓vinging �-�_ � ° `" � Doors % � � � /' � � �- � ��� ��� o � � �/A110 N SEC�10 N � �o _� �o = ��� � E 54" min. �� � -� �� �� � � � 12"min 36"min � � � � 12"min 24 min. I 60 min � i � i � i � D _ _ .i so°m��_ ❑ 2"c u rb � � = m in ts" (c) (d) � Free -Standing Built-inFountain (a) 60" Diameter �ace (b) T-9iaped �acefor180DegreeTurns 125"-1.5" � � � < Fountain or or Cooler � � � � � ,�� � � ,����� �' `,.��V \ � F1G. 39 (a) (ADA) � - � _ � cooier (ADA) -4.2.3 WheelchairTurning �ace. y�� ��� HANDRAIL RG. 27 (ADA) RG. 3 (ADA) lYie space required fora wheelchairto �, curb any DRINKING FOUNTAWS AND WAI�RCOOLERS WHEFICHAIR TURNING SPACE make a 180-degree turn isa clearspace �``�'� ��� ��"m�n as°m�� wi� of 60"(1525mm) diameter(see Fg.3(a)) or � � 12"min � _ /f / � � � � � � � � �, , a T-shaped space (see Fg. 3(b)). ' I� L o � ,\Y� � , � � � ° o � (d) (e) (f) " . � � Front Approach - 5iding S1ide �de Approach - Sliding Latch 9de Approach - 9iding � _ � N � � Doorsand Folding Doors Doorsand Folding Doors Doorsand Folding Doors �r`ir �G opt. <�/�+ `,�� �! `� � p�� 4"max. clearwidth � anyamount � and 48" min � i ` � ��� ��� base RG. 25 (ADA� NOlE: AII doorsin alcovesshall comply with � � � ' ���� ��� elevatlon pl8n MANEUVERING CLEARANCES AT DOORS the clearancesforfrontapproaches V ��� ��. -� - Wa�� (a) Side ReaCh PoSSible ` � - greaterthenl2" greaterthenl2" �8C�8� - 4.4 PYOtI'UC�IIIC� �bf2CtS �S � �5 � � � � � � ti. tt = � 1r �� _ " o - � � � 4.4.1 General. 36"min E � � � � � � �.�F�..�...r..r.�—,.��._,,.-� � % � /// �/ � � % / ° � , Objectsprojecting from walls(for � � � � aa°mm. aa°mm. exa mple, telephones) with their lead ing f � l edgesbetween 27"and 80°(685mm and r � ' - � � s ' 2030mm) above the finish floorshall }. . � � � cane range protrude no more than 4"(100 mm) into f' '� plan elevation +,� walks, halls, corridors, passageways, or \ ����\. �� ���.,��� .A\ �\\�_ _ � Fg. 8(a) Fg. 8(b) Fg. a(c) aisles(see Fg. 8(a)). Objectsmounted ,� ��� ������ � � � waikin with theirleadin ed esat orbelow 27" �� "�"'""�'"""`� mm so^ s^mm 3o^min g ParalleltoaWall Walking Perpendiculartoa Free--3anding Overhanging 9 9 "�'�;�� ';-'. vertical ground rail plans wau ob]ect (685mm) above the finish floormay _ protrude any amount (see Fg. 8(a) and �'� �� _ se e � ���, - ,_..,. ..� .,, ,.;.. _ . ... - -- (b)). Free-standing objectsmounted on 36°m�� plans '2°max ,z°max. postsorpylonsmayoverhang 12" � -� � � � (305mm) maximum from 27"to 80" D 3 * Heightto heighest ° o operable partswhich are � 51711Tt t0 mm a ove t e groun OI' � ,z°m;� �j � �, x � �y finished floor(see Fg. 8(c) and (d). � � es9entialto basic protect � = operation oftelephone. shaded area � }y Free-standing objectsmounted on posts from cross- cane hits or pylonsmay overhang 12"(305mm) 1650 Fallridge Road, Suite C-1 � � ' ost or � � � A � \\���_\�\�` trafi�ic p maximum from 27"to 80"(685mm to Vail, Colorado 81657 \ �\ � � � � \\\�;�� � — 2030mm) above the ground. � � F1G. 26 (ADA) py�n f. 970 476-4901 p.(970)476-6342 before rolling with elevation -M/O HINGED DOORSIN SERIES � person hits extended platform - can����,�gte greaterrthag12"because Reference 9te Plan (sheetA1.00) forType ADA (b) Forward Reach Required A (Accessible Unit) locations. no one can approach the COMPLIANCE 2 object from thisdirection �X � = elevation — - ' FIG. 17 (ADA) RG. 44 (ADA) � cB _ 1 � plan Codes& RegulationsReferenced: DCAMPLESOFmGEPROIEC�ION MOUNl1NG HEIGHTSAND CLEARANCES � � � ��� ADA (American DisabilitiesAct 07-01-99 Edition) �\ Fg. 8(c-1) Fg. 8(d) AND HANDRAIL IXTENSIONS FORIELEPHONES , � FHA (Fair Housing Act 04-01-99 Edition) ��� �; �� � OverHead ObjectsMounted on postsor Ha�rds pylons FHADM (FHA Design Manual Revised April 1998 Edition) ANSI (ICC/ANSI A117.1-2003) AO 01 FIG. 7 (c & d) �G� $ Note: Only a portion of applicable codes& regulations ■ (ADA) CHANGESIN PROlRUDING OBJECTS shown, see each applicable code manual fora �� complete list of all codes ISSUE RECORD 08/02/13 PERMIT SUBMITTAL OCCUPANCY GROUP: RESIDENTIAL R-2 ReviewedforCodeCompliance Code: 2012 International Building Code (IBC) TDWN DF UAIL By J Mondragon at 8:48 am, Sep 19, 2013 FLOOR AREA: 2408 S . F. OCCUPANT LOAD: 1 PERSON PER 200 S. F. NO. OF OCCUPANTS: 12 NO. OF EXITS REQUIRED: 1 : , EGRESS WIDTH REQ. _ # OF OCCUPANCY (12) X .2 = 2'-6" � _;, EGRESS WIDTH PROVIDED= 3'-0" ` ' -� �A z,_o,,,� � ' a � � � � � �� �- _ - � COMMON PATH OF EGRESS TRAVEL PERMITTED : 125'-0" �� ������� �AZ�_4; MASTER , -� � �� '���; SUITE � / COMMON PATH OF EGRESS TRAVEL PROVI DED: 40 —0 MAX. 0 11�_6��X ,8�-o�� , � ' / , . � ,�� , . � 0 � BALCONY � � � � i / DECK � � i / I / i BEDROOM 1 � � � � � O / � i � 10'-6"X 12'-1" � / I � � � � / / / � � C 3'-0" / / � � � A 2 0 �p / � � � � / / � � GFI � / � ��6' p" � _ _ ' / � � / � � / / TV BALCONY � � L___________ ___ A2�.8" ____r _ A2�_8^ _ _ _ L _ _ � � LINE LEGEND � � ° �` ' � ' z w � � o� � � ` � m __ 1_— _— _-1 __ ° QP�`�\/ � � P � O � � MAX EXIT TRAVEL - - - - - - - - - - - - - - - - - - - - - - - - - M - - - - - - - - - - - M ♦ KITCHEN m ��`�� — � —i— �--�A��-,o� __-, � � � ♦ ' ' (n 0 c� � 15'-4"X 8'-0" � .0�� il / 3 � 3 I Q � �� � �O• � 'A 2' 0"i �A 7 4� A 2,�4� � \ — � / w ` � 3 3 i - � EXISTING � � , COMMON PATH OF EGRESS ---------------------------------- � � ----- ♦ I i � M E C H R O O M � Q ,a� � ��A 2,_a„� i � M � I i J o � � � � � � � � 6'-9"X 10'-3" � � � � i LAUNDRY O ` � , � � i � ROOM � � m U � M��XIMUMEXITSEPARATION — - - - - - - - - - - - - - - - - - - — ` , - ' O � ; , ; ; 5�-9°X �o�-3° � J ` ' � � I I J `� Q � 1 � I � iI - � � > Z - x I O � / � / � I � �;�`� J B 6, �„� - � � \ � '� � Q � m � / � � � I — � A�' �° , � �� V GREATROOM � - -� - - - - - - - - - - - � - - -� �� i _ �- - - - - � `� �.i 30'-6"X 15'-6" i � - �� j _ ��./�,� � � � I � I I� I � I ' � �� � \I �A�3, 0„ � � _ � � � � i I BEDROOM 2 i BEDROOM 3 I ��� � i � � �" � � ��� A6.03 ;� � � 13'-0"X 11'-10" � 12'-3"X 12'-6" � � � 7 � � � I � r � ! � -- � ��.� , � / I ENTRY � � — � � � _ �� ------------------ � -�� � i _� _ A � : - � �: — �� _� L _ A z,_o„ � � . , — �_. � , ���� ��� � ���' �� � jl ��� � . �r�� ��G,� y� �� UP � E� I T I N G D IAG RAM .�x .N , . .� � �._ � . .. � . A0.�2 1/4"= 1'-0" f � r }. . , ,� ! ` ' �� � � <�,��,R..��•,�.:� 2X DIMENSIONAL - LUMBER @ 16"O.C., SEE PLANS FOR LUMBER SIZE,TYP. - - 5/8"GYPSUM 1650 Fallridge Road, Suite C-1 WALL BOARD Vail, Colorado 81657 f.(970)476-4901 p.(970)476-6342 EXITING DIAGRAM WALL ASSEMBLY 1 / 1 1/2" = 1'-0" �0 ■ 0� � ��� ISSUE RECORD DEMOLITION LEGEND Reviewed for Code Compliance 08/02/13 � � Code: 2012 International Building Code (IBC) � ti � wa��s To BE DEMOLISHED PERMIT SUBMITTAL r�W,� �� �'�qr� By J Mondragon at 8:48 am, Sep 19, 2013 � NEW STUD WALLS 0 EXISTING WALLS 2X DIMENSIONAL ,�� FLOOR TO BE LUMBER @ 16"O.C., � � DEMOLISHED SEE PLANS FOR 3'0" LUMBER SIZE,TYP. S ��2" 9:�„ � � ���1/2„ 5/8"GYPSUM � ����� WALL BOARD � � � _ ������ � \ \ _ \ _N / � � / � _ � � / � � � WA L L AS S E M B LY 1 M �A 2�-°.� , ° , � � � 1 1/2" = 1'-0" d. / , � "' \��� ' MASTER � � � � �A 2'-4� � '�� SUITE - - � �r;:, � �` � � � 11'-6"X 18'-0�� _ o �, � . I � r8,1 � - � DECK BALCONY I � ' 1 ��2" �T S��2„ \ � 112'-4 3/4" — � l`�J'�S:p 1/ BEDROOM 1 � � �-�\ 10'-6"X 12'-1" 112'-4 3/4" O � I � 2'-0 1/2" 5 1/2" . c s�-o° N INIT'.�J. �. . . . O � ;/ � � � . . . . . . _ O � � M GFI $�_O�� Cg.6�-�� ° - � - ` 112'-4 3/4" ��� 5'-0 1/2" I�� 8'-3 1/2" N � � O � - - � 111'-3 3/4" w � ' BALCONY '� a z�-a° 5 1/2" n 2�-a° � � 1 � o � CV � - / � � �i J � %� � � � : / �t. N `" ----- -- --1--1--L-- J O w � � n N M P 111'-4 3/4" � I 111'-4 3/4" � x � �/ . . _ . . . . . . . . �' �� A2'-10- - � , � O U � c\ 14'-5 1/2" 5'-6�� 3 � I I � � � M � KITCHEN � �� s �i2° 5 �i2��� _ �A�,_o,,, 3 � 3 �A �,_4„ q z,_4„ � EXISTING W � � 15�-4°x s�-o�� "' I I � MECH. ROOM � z � Q a�i Lf') . . .(A 2� �" `�' � � O � � � N � � � � 6'-9"X 10'-3" � � J �� � O O LAUNDRY Q a � � � I I I � o � O N ------------ -- ------ --------- � - ROOM m U - -------- -------- N - --- -- ------ - I � O LL 5'-9"X 10'-3" j � 00 J � � �� � — ���� 00 � : o� � � � � J N Q � - - - — ' - - - - - - - - - - - � ��� /�� � � � � Z 15'-4 1/2" 5'-6" � � � i - � a o �, � � ,� - � , � D � X � m iN q z�_o„ /��� ';:��; ����� � �REA WILL�NOT ���� ��:' � 30'-6"X 15'-6" � 112'-4 3/4" < <,.� �� 3 1/2" � � �' �° , � ,�� ERED ' , � , � � � � 5'-0" 9'-4" 3 1/2" 3'-6" 3 1/2�-6" 3 1/2" 5'-9 1/2" 5 1/2 2'-0 1/2" 5'-0 1/2' M E AL�]' � N _ i � � '� � � � _� � � ��� � N � 111'-4 3/4" 111'-4 3/4" e � � � � _ �A��3, p„ � , �" �/ N � /� n / � ������ �p � ��� � - . ,�� X, ' � A6.03 > � . . . . . . . . . . . '/ � - BEDROOM 2 BEDROOM 3 � � � � � � � �� I� � � ART 13'-0"X 11'-10" 12'-3"X 12'-6" N � NICHE � �I _ � � � � � � / N . . . � . . . . . . . , . ENTR�Y in � � � � � �� o � � � � � - � � ' � . . . . . . � A 2 0� . . _ O . . . . . , �'� ,x s , �' �, . . . . . _ �' �'� � � i ; ���� ��� ��� ��� � jl ��� � . �r�� ��G,� y� �� UP �:-- . � . .. „ . j 'r r � r }- � . , ,� ! ` ' �� � � �;�,��•��+"'P"`•,-x--�` -� �'� � � PROPOSED RES I DENTIAL - 2N D FLOOR PLAN - - � A2.�2 � 1/4" = 1'-0„ 1650 Fallridge Road, Suite C-1 TRUE Vail, Colorado 81657 � �NORTH f.(970)476-4901 p.(970)476-6342 � � '�, 2ND FLOOR " � PLAN '� N � \ �. - - �, ��__ � PLAN NORTH A2 . OZ ISSUE RECORD DEMOLITION LEGEND Reviewed for Code Compliance WALLS TO BE 08/02/13 Code: 2012 International Building Code (IBC) °EMO�isHE° PERMIT SUBMITTAL TOWN flF Val1 '' By J Mondragon at 8:48 am, Sep 19, 2013 � NEW STUD WALLS 0 EXISTING WALLS ��� FLOOR TO BE DEMOLISHED > �;6„ �:6„ � � � � T �� � ii � � ��� ii ` � �� �i ��y;� x ���Jj `�cK�.X� ' — �,Y X i�.,�,X �x / � �/� � �� / � �. �/ �/ ��:� �� � � ��,��' � 9 BALCONY ����� � ��� ��� � 112'-4 3/4" � � x � 112'-4 3/4" � �N��`Y��� � �� � Xx Z� �� O � �?`x`��'�x. ` � � � � ��'��� l � O ' 112'-4 3/4" �"�.�� � � � � � I � � �� I I � x ���. � � � , — � / BALCONY � I I � ` I I �� � ti � � z ~ L(� w EXISITING VENEERED �� EXISITING VENEERED � I W � COLUMN TO BE COLUMN TO BE � >> � � DEMOLISHED DEMOLISHED �� � , I � �p M � v � � , w � � � i � p � EXISITING SALES � � — \ I � J �O COUNTER TO BE ��� �,��� < �, �� � I � � O � � DEMOLISHED I x � �u � I I m U � �I , I �� � � 00 x J �. ����� � �� � — � \ _ _ - - � J NQ � � � z � o � � � � Q � � I �� AREA WILL NOT m � � � ° BE ALTERED � �112'-43/4" � � x ::k _ 1 N I XX � 112'-4 3/4" � � ENTRY � ��'�� ��� q RAISED FLOOR TO �� �� BE DEMOLISHED � '1 Y�� � . �r�� ��G,� y� �� UP �..— � . .. „ . j 'r r � r }- � . , ,� ! ` ' �� � � _ �r�,��,R..��•,�.:� FUTU RE RESI DENTIAL 2N D FLOOR PLAN - ��. � DEMO PLAN - , A2.�� 1/4" = 1'-0" – - - – --- �, 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970)476-4901 p.(970)476-6342 TRUE �� � �N°RT" DEMOLITION � � ;�� �, PLAN i' I ', N � \ , � , , ���_-_-_ A2 . 01 PLAN NORTH ISSUE RECORD Reviewed for Code Compliance DEMOLITION LEGEND Code: 2012 International Building Code (IBC) 08/02/13 �� �; �� �� WALLS TO BE -� �EnnousHE� PERMIT SUBMITTAL T�WN OF VAI� ' By J Mondragon at 8:48 am, Sep 19, 2013 � NEW STUD WALLS 0 EXISTING WALLS 2X DIMENSIONAL ,�� FLOOR TO BE LUMBER @ 16"O.C., � � DEMOLISHED SEE PLANS FOR 3'0" LUMBER SIZE,TYP. S ��2" 9:�„ � � ���1/2„ 5/8"GYPSUM � ����� WALL BOARD � � � _ ������ � \ \ _ \ _N / � � / � _ � � / � � � WA L L AS S E M B LY 1 M �A 2�-°.� , ° , � � � 1 1/2" = 1'-0" d. / , � "' \��� ' MASTER � � � � �A 2'-4� � '�� SUITE - - � �r;:, � �` � � � 11'-6"X 18'-0�� _ o �, � . I � r8,1 � - � DECK BALCONY I � ' 1 ��2" �T S��2„ \ � 112'-4 3/4" — � l`�J'�S:p 1/ BEDROOM 1 � � �-�\ 10'-6"X 12'-1" 112'-4 3/4" O � I � 2'-0 1/2" 5 1/2" . c s�-o° N INIT'.�J. �. . . . O � ;/ � � � . . . . . . _ O � � M GFI $�_O�� Cg.6�-�� ° - � - ` 112'-4 3/4" ��� 5'-0 1/2" I�� 8'-3 1/2" N � � O � - - � 111'-3 3/4" w � ' BALCONY '� a z�-a° 5 1/2" n 2�-a° � � 1 � o � CV � - / � � �i J � %� � � � : / �t. N `" ----- -- --1--1--L-- J O w � � n N M P 111'-4 3/4" � I 111'-4 3/4" � x � �/ . . _ . . . . . . . . �' �� A2'-10- - � , � O U � c\ 14'-5 1/2" 5'-6�� 3 � I I � � � M � KITCHEN � �� s �i2° 5 �i2��� _ �A�,_o,,, 3 � 3 �A �,_4„ q z,_4„ � EXISTING W � � 15�-4°x s�-o�� "' I I � MECH. ROOM � z � Q a�i Lf') . . .(A 2� �" `�' � � O � � � N � � � � 6'-9"X 10'-3" � � J �� � O O LAUNDRY Q a � � � I I I � o � O N ------------ -- ------ --------- � - ROOM m U - -------- -------- N - --- -- ------ - I � O LL 5'-9"X 10'-3" j � 00 J � � �� � — ���� 00 � : o� � � � � J N Q � - - - — ' - - - - - - - - - - - � ��� /�� � � � � Z 15'-4 1/2" 5'-6" � � � i - � a o �, � � ,� - � , � D � X � m iN q z�_o„ /��� ';:��; ����� � �REA WILL�NOT ���� ��:' � 30'-6"X 15'-6" � 112'-4 3/4" < <,.� �� 3 1/2" � � �' �° , � ,�� ERED ' , � , � � � � 5'-0" 9'-4" 3 1/2" 3'-6" 3 1/2�-6" 3 1/2" 5'-9 1/2" 5 1/2 2'-0 1/2" 5'-0 1/2' M E AL�]' � N _ i � � '� � � � _� � � ��� � N � 111'-4 3/4" 111'-4 3/4" e � � � � _ �A��3, p„ � , �" �/ N � /� n / � ������ �p � ��� � - . ,�� X, ' � A6.03 > � . . . . . . . . . . . '/ � - BEDROOM 2 BEDROOM 3 � � � � � � � �� I� � � ART 13'-0"X 11'-10" 12'-3"X 12'-6" N � NICHE � �I _ � � � � � � / N . . . � . . . . . . . , . ENTR�Y in � � � � � �� o � � � � � - � � ' � . . . . . . � A 2 0� . . _ O . . . . . , �'� ,x s , �' �, . . . . . _ �' �'� � � i ; ���� ��� ��� ��� � jl ��� � . �r�� ��G,� y� �� UP �:-- . � . .. „ . j 'r r � r }- � . , ,� ! ` ' �� � � �;�,��•��+"'P"`•,-x--�` -� �'� � � PROPOSED RES I DENTIAL - 2N D FLOOR PLAN - - � A2.�2 � 1/4" = 1'-0„ 1650 Fallridge Road, Suite C-1 TRUE Vail, Colorado 81657 � �NORTH f.(970)476-4901 p.(970)476-6342 � � '�, 2ND FLOOR " � PLAN '� N � \ �. - - �, ��__ � PLAN NORTH A2 . OZ DEMOLITION LEGEND LEGEND ISSUE RECORD Reviewed for Code Compliance WALLS TO BE � RECESSED FIXTURE Code: 2012 International Building Code (IBC) ° x�` �EnnousHE� 08/02/13 f(�W� (J� �q�L ` By J Mondragon at 8:48 am, Sep 19, 2013 � NEW STUD WALLS n RECESSED FIXTURE PERMIT SUBMITTAL � (DIRECTIONAL) 0 EXISTING WALLS � PENDANT FIXTURE � FLOOR TO BE DEMOLISHED 0 LINEAR SURFACE FLUORESCENT �S SINGLE SWITCH �o DIMMER SWITCH �s 3-WAY SWITCH DJ S DOOR JAMB SWITCH O � JUNCTION BOX � � ' � � � MOTION SENSOR � T � � ._. � � �� i `� � ° `- -�� � �� • ELEVATOR CONTROL �--� ��� ' ` --- - � � ,^ � � �� i � i �-- � � � i ► � .'� � i i 0.---�\ i � i i EQ 2'-0" EQ � „ � i I � � i , ` i � � � �� � � �i O � �\ � I � O � �� 1 '� � - �� 1 0 0 � � � O / � � � / � �\ ��0 / / � \ �'---�� / � 1 / � � \ � \ � �� -�� /' / � � ��-�� � / 1 / � � `\ / ' � I _� �O / I \ \ , �` � ♦ / � 1 I �— � � � i O �i��� �� ��� �� ' ``\`� �- �,' - ��� �` � GFI � � � � 0 �-_ 5, 6�r / � (fl � ��-- -- --�� j � w � � � �� �` O � r .' 0 �, ,i � _ Op . _ o � , N O � 1 U � o M .. �� o _,, _ __ ,___ _ �_ _ _ _ _ _ , w � � �i M _� \ �� �� / `\ � �II I � � � O � / �� � � \ / � � ,I M ,� I MI � ` /������/ \�/ �i�� � i� � w � 1 / / � / � \ u i .^ \- \ / / � � i � I C'O � �- - - - - -1 � � � \ 3 3 �----- O � O d � �/'� � �� � � � � �� � � W � i�\ � � \ '�/ 1 o g , 1 � �� � � / � ti-r----� o J � �-� � �-� �i � `\ / � / \ � 1 � 1 � � / � � � � � . , N Q � � � � � ��, �� , �, __ ____�r-__ , ; , , L - - - -_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ,�> � � �C - - - - — - - - - - - - - - - - - - - - - - ,� � � . _ / � '/ O � \\ � � � EQ. EQ. � � � � ► w ' V � SD� /�� �� I � � i 1 ' N , � � �; '���> '�, � � � � � � w Q , w I ��-��� � --' � � � i � � � � � x � � 3'-0" <Ci? � 3�_��� � � �� � <� / � � �'< ��'� �� _ \ � ` � � � \ � � - I - � � \� � I - � � � � / I o � o � �. � � ��XX �. � � i � � � r i i � x � i �� ��� � � � � �� <C� � <C3�.�` �` �� ��� � � � � � ��� ' --- -- ---"� � � ��8 � �. � � ------ ----� �i � �-' ��. �� ��� /� u.l C1 0 � w � o >, � ����� � ��� / w O � � �}� ` � j x 1 X � .. __ _ - - ��Y�+ 1 . �r�� ��G,� y� �� PROPOSED RES I DENTIAL - 2N D FLOOR - ��� R E F L E C T E D C E I L I N G P LA N �T^"�:x�Ty�N���.Y� � f ; A2.�� 1/4"= 1'-0�� r }. ,� ! ` ' t- � � �r�,��.�••�•�"`•,�--�` i,^ �'�: . � , TRUE 1650 Fallridge Road, Suite C-1 NORTH Vail, Colorado 81657 /�� � f.(970)476-4901 p.(970)476-6342 i� I`� RC P ` N ' � ,� � ; PLAN NORTH q2 . O3 12'-5 1/2" ISSUE RECORD Reviewed for Code Compliance 3�-0�� 5 1/2�� s�-o�� Code: 2012 International Building Code (IBC) � 08/02/13 5'-11 1/2�� f��� �F �r,��� By J Mondragon at 8:48 am, Sep 19, 2013 PERMIT SUBMITTAL I 0 0 0 0 �� ��. � \��� o � . . . . �J �.� i �� ��. �. � (V CO NN . . - _ . . . . . . . . . . . . . . . . . . .. "i � . . . - -- - - - ; � 2A � , � --- � � � � , �� � - - - / I � I 5 -A6.01 3 I r' � ih �o = � I I I _� o � __ � � _ _ _ — _4A- _ _ $ ao — -- ^�— � � � , � �' . � A6.01 �4 � - �., � �; '� — � � �6 , /� � - � � A - _ - - N - - \� � � � � � \�`. � � . . . . . , � . _ . I - 0 � . . . _ . . /��� �' . . - � - - � - - M M _ �. . _. .—. .—.- I .. - . . I� i � o � _ _ \ ) " , � � Q GFI / \ I � � 6'-11 1/2" 5 1/2" 5'-0 1/2" � 5'-111/2" � O �� � � � ��� E N LARG E D MASTE R BATH , � o� z E N LA R G E D B AT H 1 ; �,���_ ��_��� \A6.01 , W A6.01 ,�z�� _ ,�-o�� �� � � � ti 3'-0" 5 1/2" 9'-0" �— � L(� _� {� �. w � _��, �: �� O � U � 0 � � � M w � � � � Z � o ., N � � J o � / � Q a - o - O �y'� N � / N W U � � / � � � � � � 2 2 � 2 2 � � � M � � � M � J w w � w = = J N Q o z o z z o z � o � � � � � � � � � � � � � � z z w z z - w J J pp = J J � pp = N U � U � G� � U � � j U � N Cfl � � � / �� � � ,- o � � � � N ; e �-�� o �, �- oo �� e - � � V . � , . . � � � _ � �� _ _ �� � � �� _ � � �, .- , � , . , . , � � � � � � � � � �- � , � � � � � / � N � `�' � / A / `—' N � M \ M V A / � i � i i �� � .- � � �- V � � i� � I 2'-6" 1'-6" 1'-6" 3'-0" 2'-1" I 3'-3" 3'-6" ��_6,� ��_6�� 4�� ��_3�� 3�_��� 3,_��� ��_3�� � i 5 1/2"� 2�� � BATH 1 I NTERIOR 2 i 4\�� BATH 1 I NTERIOR 1 %3� �A�� MASTER BATH 1 � MASTE R BATH 2 A6.01 ,�2�� _ ,�-o�� A6.01 ,�2��_ ,�-o�� ,�2��_ ,�-o�� A6.01 ,�2�� _ ,�-o�� ��� �p� � A6.01 � / �,��.� �� � 8'-6" 5'-0 1/2" � /� 5'-0 1/2" 5 1/2" 3'-6" ; . , j1 I � �� � �r`,� ��,,°� y�, ��� � , �� � , � � � � � �,�...-.�:x��;..�: ,� . _ � _ _ _ ;. c� � c� c� c� a O = � � � � � I O = O = O = Yt .. . . � . : 0� � 00 � 0� � � Op � �f:- , ' . . �U WALK-IN J J J J SOAKER TUB !� �� �' U U U �;� U SHOWER t- � v , . �. ,�„�„�,,,,,,a;,P,.�.�� �) � � �� � � � � � � � M � - - � (V � � N � � M I � M `� � � � � / � � � 6'-0" � 2'-6" � 3'-4 1/2" 3'-4 1/2" ✓ 2'-1" i � i 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970)476-4901 p.(970)476-6342 7 BATH 1 I NTERIOR 4 %6�� BATH 1 I NTERIOR 3 �5� MASTER BATH 4 4 MASTER BATH 3 INTERIOR � � ELEVATIONS A6.01 ,�2�� _ ,�-o�� � A6.01 , ,�2�� _ ,�-o�� A6.01 / ��2��_ ��-o�� A6.01 ,�2�� _ ,�-o„ ��� �_� ��_� A6 . 01 5'-0 1/2" ISSUE RECORD Reviewed for Code Compliance � Code: 2012 International Building Code (IBC) � 08/02/13 B J Mondra on at 8:48 am Se 19 2013 9�_4„ PERMIT SUBMITTAL TOWN �F VAIL y g , p , - 3 � i CV � � � � \ __ _ i s_ : —' � — —� � I _ _ �� � > �� �, — _ I -- � � �-- - c� 3 A6.02 5 � � O �� �I� � M . . - . , , . . . M � i c� 8 N � 2 �I CV : � I _ . . , . . . . . . . d' � �0 A6.02 7 `'' � ��� M , I 9 — - � i � � , � o O c� _ CV � � O _ . - �' M V . � M 2'-6" 1'-3" 1'-31/4" 2'-91/4" 1'_6" i 3'-4 1/4" 1'-11 3/4" /—� � � 6 ENLARGED BATH 3 �� �� ENLARGED BATH 2 O � _ _ _ _ _ A6.02� ,�2��_ ,�-o�� A6.02 ,�2��_ ,�-o,. � � � �� �� � 5'-0 1/2" � � � � ti �- - 5 8 � z ~ LC) W � � W ap � O � � � � � � O U � � %� � Q � � w � i � � � � c� � � � Z o � � _ � / " � M � � J 'o w � w � _ w � w O � Q a 2 W T Z 2 00 � = w � N � oo � � v oo � � U Z 0 Z W Z W � Z J � W 8„ _ J N pp = J pp = N J � � _ '� � � _ � o � _ � o _ � J � � � � — � � � � � Na ° �' � � oo�� � � � � � N - � � � p� > � � � � �� 1 ° � � � � � � � � � � � � � �� � � � � � �o � , , , , V N (V �� �� CV (V CV �� /� � � i - � i ' � / M \ / M � i � �. i � \ r � � � � � N 5'-0 1/2" 2'-6" 1'-3 3/4" 1'-3 3/4" 3'-0" � 3'-01/4" 1'-3" 1'-3" 1'-3" 2'-6" � � � � 8� ��� BATH 3 I NTERIOR 2 �'7 BATH 3 I NTERIOR 1 �� BATH 2 I NTERIOR 2 � 2`� � BATH 2 I NTERIOR 1 � � � � � A6.02 j ,�z��_ ��-o�� A6.02 ,�2�� _ ,�-o.. �\A6.02 ,�z��_ ,�-o�� �� A6.02� ,�z��_ ,�-o„ � �� � �� 8'-2" 5'-0 1/2" ��1]� ��� E,�@� �p� � jl �� 9�_4„ . 5'-0 1/2" Y�� � :; �r�'�' ���''� � �'� �� , � / � / � � - � _ , �, o � o = �_-- . � . .. „ . bo eo z = � � � � � a J (� f �' w W r U p 2 O }'- ' . . i � ! � 00 � 00 • r� f ��-1� _ z +�" � . \ T w �: � U � � _ d- !';�;.',., ;�- �� ���+`!P""Y---�` N �� �. � - - , _ � � N � � � �� ti N M 5'-8" 2'-6" _� � 2'-0 1/2" 3'-0° - - - i 3'-0" 2'-0 3/4" 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 ! f.(970)476-4901 p.(970)476-6342 INTERIOR � o ��� BATH 3 I NTERIOR 4 �9� � BATH 3 I NTERIOR 3 %� BATH 2 I NTERIOR 4 ���, BATH 2 I NTERIOR 3 ELEVATIONS I � � � � � 1 � 1/2"= 1'-0" 1/2"= 1'-0" ( 1/2"= 1'-0° '\ � 1/2"= 1'-0" A6.02,/ A6.02� A6.02 ,A6.02 �� � ��� A6 . 02 Reviewed for Code Compliance ISSUE RECORD Code: 2012 International Building Code (IBC) i �5'-4 1/2�� ' f�W� �� Uq�� By J Mondragon at 8:48 am, Sep 19, 2013 I 08/02/13 5'-9 1/2" 5 1/2" 14'-5 1/2" 5 1/2" PERMIT SUBMITTAL 3'-0" 1'-9" 3'-0" 1'-9" 3'-0" 1'-9"_2 1/2" ���.� � � � � � � �� — - - - - - - - - - - - - - - - - - - - - - _��-- I I I I I � � _ I I I I I � _ � - �',�. �' �� _ CV m - - - � - - - - - - - - - - - � - - - � - - - � - - - - � m�- N �.r _ � - , _ � REF. � - � �_. - , � M \ — ., I M yi — — _ v \ — �f _ r/ - . _ . . . I I I I . . . . — I � I —� � � _ _ I C �_. I __--�A� r 'li __' � ��' � _ _' I —� _I �_ � 1 — ( —_ _- �� _ — �� . — . . . . . . — _. . . A I�/ I ' � � � � ��_ � ���� - � _ _ _ _ N N �_ — �--- � - � � � � � � A6.03 � - co i+'� � _ 55" FLAT SCREEN - `�� 3 �� � � -� � � � _ � � I I I i -- A6.03 5 "' _ � _ „ � o I-I - _ >- � g � � �((�� _ _ _� - � �-_ o ° -' - - � �� U � . . . . .,� � N - - �.., � � � � _ _ ,I'� - I. _ _ _ _ � M - - - � ' N _ � _ -- - _ ) - _ � ���� _ � — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - ( -� - _ � � �, �� � — �� � Lf> EXISTING - �� � FIREPLACE � � � TO REMAIN _ _ �� �� , � _ _��-� ' _ _ _ Q � - - � - _ �- � � 4 � � �� _� - � � �V� �� �\\�� �� ���;�� 15'- 1/2" �_ __f _ - 1 � � { - - - - - �;, , _ - �� � �-� � 7 FIREPLACE / TV WALL 4 ENLARGED LAUNDRY � � � ENLARGED KITCHEN PLAN w � A6.03 ,�2�� _ ,�-o�� A6.03 ,�2��_ ,�-o�� A6.03 J ��2��_ ,�-o�� > � �_ '�� � � Z w � O w � 15'-4 1/2" �/ � 5 1/2' 14'-5 1/2" 5 1/2" � Q M M 3'-0" 1'-9" 3'-0" 1'-9" 3'-0" 1'-9" w Q � i � 2 1/2" � r I� O V t.� � i � Jp a 0 ,, , , , , � m U �" ��, ,� � , , � 00 �� ; �� J , �� � � \��� 0 0 �,—' � � / ` � � c�l Q � , � � � � � , , � � � � , � � � � , � i� � ,' i � 0 � 0 ,� �,0 � ' 0 ,� Q �,.,_;�_�L� , i i i � � i ���i i i i ,� i i � i � i I� ����,�,� '���I V �o _ � � N �. �� � e o0 00 0o e e e e � m � � - -'0 0��� �-'0 0 �� 0��� ��/ � , ,\ � � �� o LL �� , , M POSSIBLE MANTLE OR � �� ,' � SHELVING SYSTEM, RE: ID � o � � � �� �� � i � ,� 3'-0" 1'-9" 3'-0" 1'-9" 3'-0" 1'-9" 21/2" 14'-5 1/ ' � ��'�� ��� q �.�' �j �s��� MASTER FI REPLACE/ TV NOOK 'S o LAU N DRY I NTERIOR 1 2� KITCH EN � j1 � � 1/2" = 1'-0" � 1/2"= 1'-0" � 1/2"= 1'-0" Y�.. 4„ � A6.03 A6.03 A6.03/ . ��� ,� � �� ��/ �� ��� � ��� ,��� y� �� �..— � . .. ,� . ;. + , ; r }- � . , ,� ! ` ' �� � 3 1/2" 15'-4 1/2'����, -3 1/2" � '�:�Y.aiR+�IYA"�f�lr \ ` `'-4 � �—I /i " . ' . . .. \\ - � N LL N e e e e � o e � LLJ r- F- � /'/ � � � � �� � � � �� �� � � \`� � \�� W - � N Q N / / \ / � / � � _ � � � . . � � O � Lf) I o / �, 0 �,; c� 1650 Fallridge Road, Suite C-1 N �� `� ,' `� ,' \ �' ��� z Vail, Colorado 81657 �� `� ,' `� ,' ` ,' �� � p f.(970)476-4901 p.(970)476-6342 � � �� INTERIOR 1"� 1'-9" 3'-0" 2'-01/2" 3'-0" 3'-0" 1'-9" 2�� ELEVATIONS 3 1/2"-� 14'-9 1/2" 3 1/2" 6� LAU N DRY I NTERIOR 2 3� KITCH EN 2 � 1 A6 . 03 � 1/2"= 1'-0" 1/2"= 1'-0" A6.03 / \A6.03 % �� '��\\ � � I / ISSUE RECORD \\, ���, 08/02/13 Reviewed for Code Compliance ����� PERMIT SUBMITTAL Code: 2012 International Building Code (IBC) ��; �� f�W� �� �lA���� � By J Mondragon at 8:49 am, Sep 19, 2013 �\ � ���. ��\ =��� , �, �_ __ -�-� - � / , ,, - � _,�_ � - � , , - � \ _ � / , -� ��� - �-_ � ������, \ / , , - - � � , - , _� _ __ _-`, �, _ - - -- -- � � - -_, .. � _ �� - - �_�_ � �, _ _ _ , - - - = -� , ,_ , , � . , , _ :� , ��,:, , ,, - - � - - -� � - - - - - _ , , _ - - - - � � � � - - _ -- T- , , „ __ - , � - � - — - —_-- � - - ��,_ �_, ___ _ _ , - „ �1 ,,, , , -- ` , � _ ; -� - -- � - - � � - — , , -- --- � __ �_ — � _ , ---� --- -_ _ `\;_ , � _ � - - - _ ; � � � - .�=�- . -� �-�- � _� _ ��_ -- _�( - _ _ - �__�� — l��--� _— �_ _ � � � � — _ �— — � r,- _ _ �'� — _ ��— �� ,� � _ , —; �= — _ � ��_ _� — ' ==� �'--� �=� ,, �` — \ _ -- — - r=�—( _ - c- , f� �_ -j—�-J� � �— / - - - L==�- - _ - O � �� '— � � � � �,. ' _� �r� - - —�i � _� �� -i� �= - - '' � _ _ - ,- � � / � , �_ � � � k � � � � � ti � \ `�; - � � � � - J � w o0 ' ��' � O � -- , � � U� � M , U M � � w � : , ___ � � �, Z o 0 0 O � O L 3 \ 3D 1A mU a � �_� � � � A6.04 � � 3D I NTERI OR 1 � � Q � � � > A6.04 ; �' Q , V ,�\ \ �� , %, � ! � N ' \ � , � — \ � OC � � �� �� \ , � � _ _ _ _____________________ ___ , — � ���� ��� � �__ i ,� �� � _� - � I � �,� -- \ \:��;� ��,\ � .. /� \,\�'\��\\\'�` � `i" � —�a ——� — \�,\ \�\, � �r��, ��G� _-_ - — o a o \� �\; y� ��, ;' �, � �i� =� ' ��'� \\\ � � � �, , �� ., �' _ " � ��� - �, - � _ � �� - - �� �� � � � `° � �\ �l - � — �\ � � � rf�� �_ - �\�\ �\\ �� , — � �� � � ,���, � a_ - _r \��,, \;,: �.�.�:�.�_.... ,� ���� ,_ _ _- �" ���\ \\� �� �� �� i. - _ � �: � �� }�-_ IG � y�i = � :\\\\ � ` , : � , a� � . A � � �`. r . ,� �� � � o _ � - � , ,;� \ �� -- . . - �,�_ � - --------------- r ,, _ _ ,, 0 � ;��� � ---- � � � �� � ���� i ,,,:, � ;�.,�=.R-�;..:.�.+µ�� _ - - , � ' � . 1=�r -- _ --- ,, - � _ - _ -- - _ ,- _ „, _�� � / ,��- � 1650 Fallridge Road, Suite C-1 -�' Vail, Colorado 81657 -- � ?� f.(970)476-4901 p.(970)476-6342 INTERIOR � -�\ PERSPECTIVES 4 � 3D 1 B 2 �� 3D I NTERI OR 2 � � A6.04 A6.04% �� A6 . 04 ISSUE RECORD 08/02/13 PERMIT SUBMITTAL Reviewed for Code Compliance Code: 2012 International Building Code (IBC) TOWN (1F VAI,� �` By J Mondragon at 8:49 am, Sep 19, 2013 � , , � � � i ' ' ' ` ` \ / / � � ' � ` � / , � � �� � � � � � � / � � � � � � � � � � � ,� � � � % � , � � A / � � \ / � � � � X � � � � � � � � � � � � / \ � � � � � � � � � � � � � � � � � � � � � � � � / \ � � � � / \ � � ; ; �� � � i i / � � i � STYLE A STYLE B STYLE C Z O � DOOR SCHEDULE � DOOR STYLE DOOR SIZE DOOR TYPE w � ti STYLE A RE: FLOOR PLANS INTERIOR FLUSH Z � � STYLE B 6'-0" X 6'-8" BI-FOLD CLOSET w � � � O � STYLE C STYLE C ROLLING BARN DOOR U � � M wQ � � � Z � o � NOTE: ALL DOORS TO BE 6'-8" HEAD HEIGHT, � J 'o RE: FLOOR PLANS FOR WIDTH. Q � 0 a � � U J � Q � � Q V � N � OC � ���'� �°� � ��' °� � jl ��� � . �r�� ��G,� y� �� �•-- . � . .. ,� . � + , ; r }- � . , ,� ! ` ' �� � � �;�,��•��+"'P"`•,-x--�` I,^ �'�: � 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970)476-4901 p.(970)476-6342 DOOR SCHEDULE A9 . 01 Code: 2012 International Building Code (IBC) ° MECHANICAL SPECIFICATIONS. 14. DUCTWORKINSULATION: T�WN (1F VAf� By J Mondragon at 8:49 am, Sep 19, ZO�3 a. ALL DUCTWORK SHALL BE INSULATED CONSISTENT WITH THE REQUIREMENTS PER SECTION 604 OF THE 2012 IMC. NOTE:ALL SYMBOLS SHOWN ON LEGEND � b. INSULATION SHALL BE UL USTED IN COMPLIANCE WITH A FLAME-SPREAD INDEX NOT MORE THAN 25 AND SMOKE DEVELOPED INDEX NOT MORE THAN 50, PER M EC HAN I CAL L EG E N D ARE NOT NECESSARILY USED. 1. GENERAL: THE 2012 IMC. INSTALLATION SHALL BE IN ACCORDANCE WITH IMC REQUIREMENTS. � O a.FURNISH ALL LABOR, SUPERVISION, MATERIALS, EQUIPMENT AND FACILITIES NECESSARY TO FURNISH, FABRICATE, DELIVER, STORE AND INSTALL ALL WORK c. RECTANGULAR SUPPLY, RETURN &TRANSFER DUCTWORK SHALL BE INTERNALLY LINED WITH A VAPOR RESISTANT DUCT LINER OF THICKNESSES SPECIFIED -Hws- HEATiN�waTER suPP�Y oa OUTDOOR AIR � � NOTED ON THE DRAWINGS AND/OR SPECIFIED HEREIN. BELOW. -HwR- HEATirv�warER RETURN RA RETURN AIR (� � N � N b. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL WORK NECESSARY TO MAKE A COMPLETE SYSTEM WHETHER OR NOT SUCH DETAILS ARE MENTIONED IN d.CONCEALED ROUND, CONCEALED OVAL &OUTDOOR AIR DUCTS SHALL BE EXTERNALLY WRAPPED WITH FIBERGLASS INSULATION WITH AN EXTERNAL VAPOR -cws- cHi��E�wATER s uPP�v sa S UPPLY AIR �-' V � O � THESE SPECIFICATIONS OR SHOWN ON THE PLANS, BUT WHICH ARE OBVIOUSLY NECESSARY TO MAKE A COMPLETE SYSTEM, EXCEPTING ONLY THOSE BARRIER. REQUIRED R-VALUES ARE SPECIFIED BELOW. � O � -CWR- CH�LLED WATER RETURN EA EXHAUST AIR � U PORTIONS THAT ARE SPECIFICALLY MENTIONED HEREIN OR PLAINLY MARKED ON THE ACCOMPANYING DRAWINGS AS BEING INSTALLED UNDER ANOTHER e. ALL SUPPLY, RETURN &TRANSFER DUCTWORK LOCATED WITHIN THE BUILDING ENVELOPE SHALL BE INSULATED TO A MINIMUM OF R-4 (1" LINER)UNLESS � � � SECTION OF THE SPECIFICATIONS. � � � � SPECIFIED OTHERWISE ON THE PLANS. -sMS- sNOwnnE�T suPP�Y RAD RETURN AIR DAMPER f. ALL SUPPLY DUCTWORK LOCATED IN ATTICS OR OTHER UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF R-8 (2" LINER). ALL OTHER DUCTS IN -sMR- sNOwnnE�T RETURrv sao SUPPLY AIR DAMPER � C � � ~ Z.WORKMANSHIP: -RFS- RADIANT FLOOR SUPPLY SG SUPPLY GRILLE O � O O UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF R-6 (1-1/2" LINER). � '� � Q � a.THE WORK SHALL BE ACCOMPLISHED IN A THOROUGH AND WORKMAN-LIKE MANNER SATISFACTORY TO AND MEETING THE APPROVAL OF THE OWNER AND g.ALL OUTDOOR AIR DUCTS SHALL BE INSULATED TO A MINIMUM OF R-6 WITH A VAPOR BARRIER. -RFR- RaoiaNT F�ooR RETURtv Rc RETURN GRILLE � � � ARCHITECT. -�- �AS TG TRANSFER GRILLE � � � � X � 15. EXISTING TEMPERATURE CONTROL DEVICES: -MP�- nnE�iunn PRESSURE tvaTURa��as SD SUPPLY DIFFUSER � ��' N ((3 U 3. MATERIALS: a. THE HVAC SYSTEM SHALL BE PROVIDED WITH 7-DAY PROGRAMMABLE AUTOMATIC SPACE TEMPERATURE CONTROL DEVICES THERMOSTATS AS SHOWN ON � � � V- = � � � PIPE RISER RD RETURN DIFFUSER �L � � +r a. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND THE BEST OF THEIR RESPECTIVE KIND, FREE FROM ALL DEFECTS AND OF THE MAKE AND QUALITY THE PLANS. THE THERMOSTATS SHALL BE CAPABLE OF SCHEDULING OCCUPANCIES AND PROVIDING SETBACK CAPABILITIES TO MAINTAIN ZONE SETPOINTS � V � �('6 SPECIFIED. �� PIPE DROP TD TRANSFER DIFFUSER Q� DOWN TO 55°F OR UP TO 85°F. " PIPE TAKEOFF(FROM BOTTOM OF MAIN) QT THERMOSTAT � � U � O � b. C O N T R O L S S H A L L B E C A P A B L E O F O P E R A T I N G T H E S Y S T E M H E A T I N G A N D C O O L I N G I N S E Q U E N C E A N D S H A L L B E A D J U S T E D T O P R O V I D E A D E A D B A N D O F A T V Q N N 4.SITE INSPECTION: -o- PIPE TAKEOFF(FROM TOP OF MAIN) � p� � V LEAST 5°F BETWEEN HEATING AND COOLING. Os SENSOR(CALL OUT ON DRAWINGS) � �S 0p � a. CONTRACTOR SHALL VISIT THE SITE OF WORK PRIOR TO SUBMISSION OF HIS BID AND THOROUGHLY FAMILIARIZE HIMSELF WITH THE WORKING CONDITIONS & � PIPE END CAP c. THERMOSTATS SHALL HAVE NUMERIC SET POINTS IN °F,ADJUSTABLE SETPOINT STOPS AND SHALL BE MOUNTED AT 48"ABOVE FINISHED FLOOR ADJACENT TO � N � Cp ap CCS EXACT NATURE OF THE WORK. THE ROOM'S LIGHT SWITCH. -� PIPE CONTINUATION � FIRE/SMOKE DAMPER � U �ti � b. SUBMISSION OF A BID ACKNOWLEDGES FULL RESPONSIBILITY FOR FURNISHING A COMPLETE AND FUNCTIONAL SYSTEM. - PiPE ExPaNSiotv�ui�E �� w + W � , c. NO CHANGES IN CONTRACT WILL BE MADE TO ACCOMMODATE OR ALLOW EXTRA FUNDS FOR ANY OMISSION WHICH RESULTS FROM A FAILURE TO FIRE DAMPER U 16. GAS APPLIANCE VENTING: �I� PIPE UNION - � J = O � THOROUGHLY MAKE THE EXAMINATION. a. ACCEPTABLE VENT MATERIALS, ROUTING, DISTANCE AND TERMINATION LOCATIONS SHALL COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS �� PIPE ANCHOR p-�� MOTOR OPERATED DAMPER(MOD) (� w � ? � � AND ALL REQUIREMENTS IN CHAPTER 8 OF THE 2012 IMC. PVC PIPING IS NOT ACCEPTED FOR BOILER OR WATER HEATER VENTING. F�Exia�E PiPE coNNECTioN ��� °�� 5.CODES AND PERMITS: � MANUAL BALANCING DAMPER � a. ALL MECHANICAL EQUIPMENT, INSTALLATION, ETC., SHALL CONFORM TO THE 2012 INTERNATIONAL MECHANICAL CODE IMC , 2012 INTERNATIONAL ENERGY � PIPE EXPANSION JOINT �' U N O � � ) 17. BEFORE STARTING ANY WORK, THE CONTRACTOR FOR THIS SECTION OF THE WORK SHALL EXAMINE A COMPLETE SET OF DRAWINGS FOR ALL TRADES, POINT OF NEW CONNECTION _R,p CHANGE OF ELEVATION CONSERVATION CODE (IECC)AND ORDINANCES AS INTERPRETED BY THE TOWN OF VAIL BUILDING DEPARTMENT. INCLUDING ARCHITECTURAL, STRUCTURAL, HVAC, ELECTRICAL, FIRE PROTECTION AND PLUMBING. DIMENSIONS, SPACE REQUIREMENTS AND POINTS OF e (D)DROP (R)RISE � � � � Q ��� PLUG VALVE b. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS. CONNECTION TO ALL EQUIPMENT SHALL BE VERIFIED, AND ANY MINOR ADJUSTMENTS NECESSARY TO AVOID CONFLICT WITH THE BUILDING STRUCTURE AND FLEXIBLE DUCT CONNECTION }' � O c. COPIES OF ALL PERMITS AND INSPECTION REPORTS SHALL BE SUBMITTED TO THE ARCHITECT. -i/I- CHECK VALVE U THE WORK OF THE OTHER TRADES SHALL BE MADE. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY IF ANY MAJOR CONFLICTS OCCUR. � � � 6� - � BALL VALVE � TURNING VANES IN 90°ELBOW U C Q 00 � 6.AS-BUILTS: 18. COORDINATE LOCATIONS OF ALL ROOF AND EXTERIOR WALL OPENINGS WITH ALL RELEVANT TRADES, AND PROVIDE WATERTIGHT FLASHINGS WHEREVER �v'�� BALANC�NG VALVE ��� DUCT SIZES ARE NET FREE AREA � c 0� a.CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS-BUILT DOCUMENTS WITH ALL CHANGES NOTED THEREON AT THE COMPLETION OF THE PROJECT AND PENETRATIONS OCCUR. EXACT LOCATIONS AND SIZES MAY BE DEPENDENT UPON EQUIPMENT SELECTIONS; COORDINATE SIZES AND LOCATIONS OF ALL -�- FLOW REGULATOR VALVE ??X?? 1ST NO.IS DUCT WIDTH. PRIOR TO FINAL ACCEPTANCE AND PAYMENT. OPENINGS WITH APPROPRIATE EQUIPMENT REQUIREMENTS. ��� BUTTERFLY VALVE 2ND NO.IS DUCT DEPTH. m � SECTION THRU ROUND DUCT 7. GUARANTEE: 19. PERMANENT ACCESS TO EQUIPMENT SHALL BE PROVIDED, AND A MINIMUM OF 30" CLEAR WORKING SPACE IN FRONT OF ACCESS PANELS TO THE � PRESSURE REDUCING VALVE 0 a. CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL LABOR AND MATERIALS ON ALL WORK AGAINST DEFECTS IN WORKMANSHIP AND MATERIALS FOR A COMPRESSOR, BLOWER ASSEMBLY AND AIR FILTER SECTION OF THE EQUIPMENT SHALL BE PROVIDED BY GENERAL CONTRACTOR. �_ m SECTION THRU SUPPLY AIR DUCT � PERIOD OF ONE YEAR AFTER COMPLETION. 2-waY coNTRO�va�vE O SECTION THRU RETURN/EXHAUST AIR DUCT 20. ALL EQUIPMENT SHALL BE SECURELY FASTENED TO THE BUILDING STRUCTURE WITH CODE APPROVED VIBRATION ISOLATORS. � 3-WAY CONTROL VALVE �xA'��'17��u�r 8.SUBMITTALS: � ROUND DUCT TURN DOWN i��, Q� �fi!„y� �''�•r, a. CATALOG INFORMATION AND CUTS OF ALL EQUIPMENT AND DEVICES SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW SIX COPIES OF EACH . � a-waY coNTRO�va�vE +'`� '�� `��'�"'-:•- � ) 21. EACH PIECE OF EQUIPMENT AND ALL SYSTEMS SHALL BE ADJUSTED AND RE-ADJUSTED TO INSURE PROPER FUNCTION OF ALL CONTROLS, MAINTENANCE OF {- � �} ►�, �: _ _, x SUPPLY DUCT TURN DOWN �'` i � TEMPERATURE, ADEQUACY OF FLOWS AND CAPACITIES, ELIMINATION OF NOISE AND VIBRATION,AND SHALL BE LEFT IN PROPER OPERATING CONDITION. � DIFFERENTIAL BYPASS VALVE �'�v � ���' �` * 9.COORDINATION: � RETURN/EXHAUST DUCT TURN DOWN �� J � a.THE DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW SCOPE. 22. TEST& BALANCING � � - � ,� b. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES TO PROVIDE BEST ARRANGEMENT OF ALL DUCTS, PIPES, CONDUIT, ETC. a. THE ENTIRE HEATING AND VENTILATING SYSTEM SHALL BE BALANCED BY AN INDEPENDENT CERTIFIED TEST AND BALANCE COMPANY. �� STRAINER �F� SUPPLY REGISTER/DIFFUSER/LOUVER '� * � � � NECK SIZE �" b. 5 COPIES OF THEIR BALANCE REPORTS SHALL BE SUBMITTED TO THE ENGWEER FOR REVIEW AND APPROVAL � NATURAL GAS PRESSURE REGULATOR CFM-R � � � �7 � �� 10. CUTTING AND PATCHING: � RETURN REGISTER/DIFFUSER/LOUVER r. c. ALL REQUIRED RE-SHEEVING AND ADJUSTING OF EQUIPMENT SHALL BE MADE BY THE TEST& BALANCE CONTRACTOR. NECKSizE , � ; a. ALL CUTTING AND PATCHING REQUIRED OF THE STRUCTURE (NEW OR EXISTING)SHALL BE PROVIDED UNDER OTHER SECTIONS OF THE WORK. d.ALL FINAL MEASURED CAPACITIES SHALL BE WITHIN 10% OF THOSE INDICATED ON THE PLANS. aiRVENr cFnn-o.A. =';: "�`�, 'r' �` � OUTSIDE AIR REGISTER/DIFFUSER/LOUVER ,-'�.� , �." 4 b. P R O V I D E N E C E S S A R Y R E Q U I R E M E N T S T O T H E P R O J E C T S U P E R I N T E N D E N T. N E C K S i z E �#� '�,r���,��F 1 ��;i�' c. X-RAY SLABS PRIOR TO CORING. 23. FINAL LOCATION OF GRILLES, REGISTERS & DIFFUSERS SHALL BE PER THE ARCHITECTURAL PLANS, ELEVATIONS OR AS PER FIELD REQUIREMENTS. � PRESSURE-TEMP.TAP CFM-E EXHAUST REGISTER/DIFFUSER/LOUVER -�`���y} NECK SIZE 11. CLEANUP: 24. THE GENERAL CONTRACTOR SHALL FURNISH & INSTALL ALL OF THE REQUIRED ACCESS PANELS IN THE DRYWALL CEILINGS TO GAIN SERVICE ACCESS TO THE � PRESSURE GAUGE --�- UaCFM DOOR UNDERCUT a.UPON COMPLETION OF THE WORK UNDER THIS SECTION, THE CONTRACTOR SHALL REMOVE ALL SURPLUS MATERIALS, EQUIPMENT AND DEBRIS INCIDENTAL EQUIPMENT. EQUIPMENT WITH MANUFACTURER MANDATED SERVICE REQUIREMENTS INSTALLED WITHIN CRAWLSPACES MUST BE A MAXIMUM OF 20 FEET � THERMOMETER TO THIS WORK AND LEAVE THE PREMISES CLEAN AND ORDERLY. FROM AN ACCESS PANEL. ��,� (A)SECTION CUT LINE P.C. PLUMBING CONTRACTOR � `BJ (B)SHEET SHOWN ON 12. MECHANICAL IDENTIFICATION 25. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S INSTALLATION, OPERATION & MAINTENANCE MANUAL'S RECOMMENDATIONS M.C. MECHANICAL CONTRACTOR a.EQUIPMENT NAMEPLATES: METAL, WITH DATA ENGRAVED OR STAMPED, FOR PERMANENT ATTACHMENT ON EQUIPMENT. ESPECIALLY FOR SERVICE CLEARANCES. e.c. E�ECTRica�coNTRacroR � b. PIPE MARKERS: PREPRINTED, COLOR CODED, WITH LETTERING INDICATING SERVICE,AND SHOWING DIRECTION OF FLOW. A.H.J. AUTHORITY HAVING JURISDICTION c. VALVE TAGS: STAMPED OR ENGRAVED WITH 1/4" LETTERS FOR PIPING SYSTEM ABBREVIATION AND 1/2" NUMBERS, WITH NUMBERING SCHEME. PROVIDE 5/32" 26. FILTERS: � HOLE FOR FASTENER. a. SHALL BE UL RATED AND APPROVED. d. VALVE TAG SCHEDULE: PREPARE A VALVE TAG SCHEDULE TO BE SUBMITTED TO THE MAINTENANCE ENGINEER FOR RECORD. b. PRESSURE DROPS SHALL NOT EXCEED .10"STATIC PRESSURE. 13. DUCTWORK: 27. ELECTRICAL CONNECTIONS: � W a.DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE 2012 IMC AND SMACNA STANDARDS. a.UNLESS OTHERWISE INDICATED ALL MAGNETIC MOTOR STARTERS, THERMAL OVERLOADS, LOW VOLTAGE THERMOSTATS, CONTROL RELAYS, CONTROL � b. DUCTWORK SHALL BE GALVANIZED STEEL GAUGES TO MEET SMACNA STANDARDS. DUCTWORK SIZES INDICATED ARE FREE CLEAR DIMENSIONS. TRANSFORMERS AND SOLENOID VALVES SHALL BY FURNISHED BY THE MECHANICAL CONTRACTOR. � c. ALL DUCT JOINTS SHALL BE SEALED AIR TIGHT WITH RCD CORP. #6 MASTIC ADHESIVE WITH VERSA GRIP OR MESH. b. PROVIDE MOTORS AND EQUIPMENT FOR ONLY THOSE CURRENT CHARACTERISTICS INDICATED ON THE DRAWINGS. O d.FLEXIBLE DUCT USED FOR CONDITIONED AIR SHALL BE UL APPROVED, VINYL COATED,WIRE REINFORCED FIBERGLASS, WITH MAXIMUM THERMAL c. IT IS THE INTENT OF THIS DIVISION TO REQUIRE A COMPLETE SYSTEM PER THE CONTRACT DOCUMENTS. O O CONDUCTIVITY OF 0.30 BTU-IN/HR-FT2-OF AND A MAXIMUM LENGTH OF FIVE FEET. d.COORDINATE ALL EQUIPMENT REQUIRING ELECTRICAL POWER, REGARDLESS OF VOLTAGE, WITH OTHER TRADES, SO THAT ALL SYSTEMS ARE COMPLETE AND � Q e. CLOTHES DRYER VENT EXHAUST DUCTWORK SHALL BE ALUMINUM. DUCTWORK SHALL NOT BE CONNECTED OR INSTALLED WITH SHEET METAL SCREWS OR OPERATIONAL. � � OTHER FASTENERS THAT WILL OBSTRUCT THE EXHAUST FLOW. TERMINATE WITH A WALL CAP WITH A BACK DRAFT DAMPER. SCREENS ARE PROHIBITED. e. ALL THREE PHASE MOTORS SHALL BE PROVIDED WITH PHASE LOSS PROTECTION. � � a REFER TO SECTION 504 OF THE 2012 IMC FOR MAXIMUM DRYER EXHAUST DUCT LENGTHS. f. ALL SINGLE AND THREE PHASE MOTORS, STARTERS AND DISCONNECTS PROVIDED BY MECHANICAL CONTRACTOR AND WIRED BY THE ELECTRICAL � f. DUCTWORK SHALL BE SIZED AT A MAXIMUM VELOCITY OF 1,000 FPM/.08" PRESSURE DROP PER 100 FEET. CONTRACTOR. � g.EACH MECHANICAL VENTILATION SYSTEM (SUPPLY AND/OR EXHAUST)SHALL BE EQUIPPED WITH A MEANS OF SHUT-OFF WHEN VENTILATION IS NOT � � O REQUIRED, AND BACKDRAFT DAMPERS WHICH CAN BE CLOSED ON FAN SHUTDOWN SHALL BE PROVIDED FOR AIR INTAKES AND/OR DISCHARGES. 28. TEMPORARY HEATING DURING CONSTRUCTION: h. CLEAN OUT ALL DUCTS PRIOR TO SUPPLY AND RETURN GRILLE INSTALLATION a. MECHANICAL EQUIPMENT SHALL NOT BE UTILIZED FOR TEMPORARY HEATING. J i. DOUBLE THICKNESS TURNING VANES SHALL BE USED ON ALL DUCT TURNS OF 90°. b. GAS FIRED TEMPORARY HEAT SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. � W O � v � � 0 � Z - J N Q SEQUENCE OF OPERATION FAN COIL UNIT SCHEDULE (EXISTING, FOR REFERENCE ONLY) � HEATING COIL DATA COOLWG COIL DATA ELECTRICAL OPER. O � UNIT MANUFACTURER& TOTAL O.A. ESP � SERVICE LOCATION HP TOTAL AIR SIDE WATER SIDE TOTAL AIR SIDE WATER SIDE DATA WT. REMARKS � � (E) FC-1 & FC-2: EXISTING FAN COILS SHALL OPERATE BASED ON THEIR EXISTING CONTROL SYSTEM AND SHALL BE CONTROLLED VIA THEIR OWN TAG MODEL NO. CFM CFM (IN) MBH EDB °F LDB °F APD EWT °F LWT °F GPM PD(FT) MEDIA % MBH EDB °F EWB °F LDB °F LWB °F P,PD EWT °F LWT °F GPM PD(FT) MEDIA % V/PH/Hz (LBS) � RESPECTIVE WALL MOUNTED T-STATS. UPON A CALL FOR COOLING OR HEATING THEY SHALL BE ENERGIZED AND MAINTAIN 75°F (ADJ.) � � � � � � � � � � � � � � < < � � � OR 70°F (ADJ.) SPACE TEMPERATURE RESPECTIVELY. FC-1 CARRIER- LIVING/DINING AREA CONF.RM 1550 1215 1.0 0.8 35.8 60.0 88.4 0.23 140.0 121.2 4.0 0.5 PROPYLENE 30 34.2 80.0 62.0 53.6 53.6 0.37 45.0 55.3 7.5 3.5 PROPYLENE 50 208/3/60 440 /� FC-1 SHALL NOW WORK AS MUA UNIT AND SHALL BE ALSO INTERLOCKED WITH KITCHEN HOOD. WHEN THE HOOD IS ON, THE FRESH AIR 39LA03ACFAT FLOOR w DAMPER SHALL OPEN 100%AND THE UNITS SHALL PROVIDE 1215 CFM O.A. SUPPLY. WHEN THE HOOD IS OFF, THE FRESH AIR DAMPER CARRIER- HVAC MECH � SHALL PARTIALLY CLOSE AND PROVIDE 180 CFM O.A. FOR AUXILIARY HEATING DURING MUA OPERATION SEE EDH-1 SECTION. FC-2 39LD03ACHAD-BHJ-E9 BEDROOMS ROOM 1,500 490 1.0 0.7 38.1 60 91.3 0.27 140.0 119.9 4.0 0.5 PROPYLENE 30 27.1 80.0 60.0 57.7 52.9 0.23 45.0 57.3 5.0 2.1 PROPYLENE 50 208/3/60 470 EDH-1: THIS UNIT SHALL BE CONTROLLED VIA ITS DUCT MOUNTED DISCHARGE AIR TEMPERATURE AND AIR FLOW SENSOR. THE AIRFLOW N SENSOR SHALL ENABLE THE AUXILIARY HEATER AND WHENEVER THE DISCHARGE AIR SENSOR DROPS BELOW 60°F (ADJ.)THE HEATER EXH AU ST FAN SC H E D U L E OR EQUIVALENT SHALL TURN ON. TURN OFF THE HEATER WHEN THE DISCHARGE AIR TEMPERATURE RISES ABOVE 65° F(ADJ.). ELECTRICAL DATA NOISE UNIT MANUFACTURER& TOTAL HEATING OPER. EF-1: THE EXHAUST FAN SHALL BE INTERLOCKED WITH WALL MOUNTED ON/OFF SWITCH. TAG MODEL NO. SERVICE LOCATION �E CFM WATTS ESP(IN) A V/PH/Hz LEVEL � ��BS� REMARKS (SONES) EF-1 BROAN QTX110HFLT BATHROOM gATHROOMS CEILING 100 1,500 0.25 13 1/2 120/1/60 0.9 35 �NTERLOCK WITH MANUAL ON/OFF SWITCH.PROVIDE BACK DRAFT DAMPER. VENTILATION PROVIDE RD1 CEILING RADIATION/FIRE RATED DAMPER. MATCH RATED ASSEMBLY AEC PROJECT #: 13068.00 �PVS� DATE: ISSUE: (d TWIST-IN FITTING W/ ��`�� °� AI R D EV I C E S C H E D U L E ,�v �.1 ,�5� OR EQUIVALENT 08-06-13 PROGRESS MANUAL DAMPER, ��F�'� ,��p�����J� � 08-08-13 PERMIT SET HANDLE, &LOCK NUT P � UNIT MANUFACTURER& MOUNTING FRAME �O TAG MODEL NO. USE LOCATION STYLE �E FINISH SOUND REMP,RKS LVL (NC) � INSULATED RIGID DUCT Q�� LOUVERED SUPPLY GRILLE, ALUMINUM CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS,SIZES,AND SPECIFIED CFMS. MODEL SJQ ��,0 A KRUEGER- SUPPLY/ FLOOR/SIDEWALL 1/8"BARS, 1/4"SPACING, 15° M COORD.W/ 25 1850 USED IN FLOOR, MODEL 1600 USED IN SIDEWALL AND CEILING(1600 SERIES CAN BE /,/ � W P,\� 45° 1850/1600/1500 RETURN /CEILING DEFLECTION �CH SUBSTITUTED WITH 1500 SERIES FOR LOW THICK FRAME). O , / � 3/4"35° SINGLE DEFLECTION COORD.W/ � / , ' B KRUEGER-S580 RETURN SIDEWALL GRILLE F22 ARCH 25 ALUMINUM CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS,SIZES,AND SPECIFIED CFMS. Drawn By: Checked By: Q ��� MZ TOC WORM DRIVE S.S. R=W � � CLAMP ELECTRIC DUCT HEATER SCHEDULE OR EQUIVALENT UNIT MANUFACTURER& � CAPACITY #OF DIMENSIONS EAT LAT ELECTRICAL DATA MECHANICAL SEAL AIRTIGHT � TAG MODEL NO. SERVICE LOCAT ON �KW) STAGES [HxWj (°F) (°F) KW AMPS V/PH/Hz REMARKS RADIUS ELBOW DETAIL AROUND ENTIRE SPECS ,LEGEN RO U N D D U CT TAKE-OF F NO SCALE TAKE-OFF. EDH-1 W�REN GREAT ROOM DUCT MOUNTED 18 3 12x18 -20 60 18.0 - 120/3/60 WIRE BACK TO HOUSE PANEL,PROVIDE AIR PROOVING SWITCH,DISCHARGE AIR TECHNOLOGIES SENSOR S CHEDULES NO SCALE 45° DUCT TAKE-OFF LOUVER SCHEDULE & DETAILS NO SCALE: FACE PRESSURE UNIT MANUFACTURER& SIZE FRAME TAG MODEL NO. SERVICE LOCATION CFM �L"xW"xT") �LOCITY DROP TYPE FINISH REMARKS (FPM) (IN SP) L-1 RUSKIN -ELF6375DX FC-1 OUTSIDE AIR CONF.RM WALL 1,590 30�Q4 662 0.05 STANDARD COORD.W/ REPLACE EXISTING LOUVER WITH THIS ONE. INTAKE BELOW DECK P,RCH. • 1 Of 2 m COPYRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS,INC. 0 N � GENERAL NOTES: � � S H E ET D ETAI L N OTES: Reviewed for Code Compliance � o 1. ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE. COde: 2012 International Building Code (IBC) � t� N � � 1 EXISTING 36x8 RETURN DUCTWORK PENETRATION TO REMAIN. � (,�j (� O N 2. ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER r��'� �� v�}�� By J Mondragon at 8:49 am, Sep 19, 2013 +� • � � OFFSET DUCTWORK IN DOUBLE FLOOR AND ROUTE TO THE CLOSET UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND � � p U � WALL. REUSE ALL EXISTING FIRE DAMPERS AND REWORK FIRE RATED DUCTWORK SHALL BE WRAPPED WITH 1.5"THICK INSULATION UNLESS � � �� � ASSEMBLIES IN THIS AREA. � c� �� OTHERWISE NOTED. � � � � ti 2O ROUTE NEW 36x8 RETURN DUCTWORK UP TO THE CEILING. CONTINUE 3. ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE O ,� O a O INTO THE BATHROOM CEILING AS INDICATED. C O N I C A L T E E S. � Q � �� � O3 REUSE EXISTING RETURN DIFFUSER. REBALANCE AS INDICATED. 4. ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES. � �� N � O � � � � — 4 O EXISTING DIFFUSERS TO REMAIN. 5. ALL DUCTWORK SHALL BE RUN TIGHT TO UNDERSIDE OF STRUCTURE .� � � � �('6 WHERE IT EXISTS UNLESS OTHERWISE NOTED. � (,Vj O � O5 PROPOSED LOCATION OF THE EXISTING SUPPLY DIFFUSER.VERIFY � J Q N N � WITH THE OWNER IF THIS DIFFUSER SHOULD REMAIN IN ITS ORIGINAL 6. ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL � °� � o� � � L OCATI ON OR REL OCATED A S INDI CATED. � Q � � � INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY. � U 6 EXISTING DUCTWORK IN THE SHAFT TO REMAIN. SHOWN FOR � w �'ti � O REFERENCE ONLY. 7. COORDINATE ALL ACCESS PANEL LOCATIONS WITH THE ARCHITECT. w V LLJ � , � J = O � O7 EXISTING 9" Q1 EXHAUST RISER. VERIFY EXACT LOCATION IN FIELD. � w � � � � CONNECT NEW 9" Q1 EXHAUST DUCTWORK TO IT. e 9 � � � � _ _� � (lZ � N O8 EXISTING BATHROOM BUILDING EXHAUST.VERIFY EXACT LOCATION IN O � �- V C ,,� � � FIELD. FD� � � � �� � � O � � O8 ROUTE 6" �'6 BATHROOM EXHAUST AND CONNECT TO THE EXISTING EF U � Q � � BATHROOM BUILDING EXHAUST DUCTWORK IN THE EXISTING SHAFT. VERIFY EXACT LOCATION IN FIELD. PROVIDE A FIRE/SMOKE DAMPER. IF � FD VD gp_g A � � DESIRED, ROUTE UP THRU THE ROOF INSTEAD.VERIFY WITH THE A 180-S EF 6x4 � OWNER OR THE ARCHITECT PRIOR TO PURCHASING EQUIPMENT AND 48x4 � � �FD °=� ° �-W� 13 m INSTALLATION. � 2 �UITE O O B 180-R 16x4 Vp � � -6" X 18'-0" � O9 REPLACE EXISTING 11x5 FRESH AIR SUPPLY DUCTWORK WITH 18x12 _ / FRESH AIR SUPPLY TO DELIVER 1215 CFM FRESH AIR (15 CFM DRYER — � _ �FD � ��zrarcu COMBUSTION AIR, 1200 CFM KITCHEN HOOD MUA). PROVIDE NEW � � � � � �,���� F�fi��r��., LARGER MOTORIZED DAMPER ON FRESH AIR INTAKE. � � — o� ;b`� '+r�'' ��l `'�'.� BALCONY ' \ N�` <v �;' � C) h' , t��� 1'-, 10 INSTALL EDH-1 PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. FD EF � � �k ��� � ' �>-. '� �" VERIFY HEAD HEIGHT PRIOR TO INSTALLATION. � � � � 2 ` `�. 9 - - � * � , � 11 ROUTE 4" fl� DRYER VENT UP THRU THE ROOF. TERMINATE MIN. 3' 10'-6" X 1�'-1" � � \ VD 80_S �112'-4 3/4" � � R7 � �; ABOVE THE ROOF, 3'AWAY FROM ANY WINDOWS AND 10' � �?,� 6x4 A . % � � .� ; HORIZONTALLY AWAY FROM ANY MECHANICAL AIR INTAKE INTO THE 36x8 (38x10) � �1/e �' �p `'*� �,� �,,r`�4�ti BUILDING OR 3'ABOVE IT. IF ROUTING THRU THE ROOF ISN'T DESIRED, � � FD / `��'��.`-,'�,r� �N ;i�` ROUTE INTO THE SHAFT AND UP. TERMINATE IN THE AT THE TOP OF � EDH 14 #=?�`���;�}`� THE SHAFT MIN. 3'ABOVE FROM ANY AIR INTAKE INTO THE BUILDING. Vp - - - k 400-S � (E)8"0 IF ROUTED INTO THE SHAFT, PROVIDE FIRE RATED COLLAR FOR — F� � � 16x8 A O 20x14 O 1590-OA EXAMPLE HILTY CP 643N 110/4" FIRESTOP OR EQUIVALENT. � � �� 12x10 (14x12) �� 8 30x24 L-1 O240-S � O B 1370- O TO FC-2 ^ 19 — �FD 4"AIR INLET �8 O 0 12 12 REPLACE EXISTING INTAKE LOUVER WITH NEW LARGER ONE. A 48x4 5 36x18 Vp 9 18x12 � (EXIST.) �� / �2x8 (14x10) 0 13 CONNECT NEW O.A. INTAKE BACK TO FG1 IN THIS LOCATION. �� C — � (E)SFD �—� . . B 560-R � � 15 18x10 � � 14 EXISTING 8" 0 FRESH AIR SUPPLY TO REMAIN. n � - - � _ _ _ _ _ _ O _ L _ _ JI� �`'� — O HOOD '� (E) R E T U R N ��E) 1 2 x 1 0 � 15 ROUTE 10" 0 KITCHEN HOOD UP THRU THE ROOF, TERMINATE 3' 280-S `� PLENUM BO�1 e ABOVE THE ROOF, 10' HORIZONTALLY AWAY FROM ANY MECHANICAL A 48x4 1 2 0 0 C F M 390-R 390-R � � AIR INTAKE INTO THE BUILDING OR 3'ABOVE IT AND 3'AWAY FROM B 16x6 B 16x6 �� � , � w ANY NATURAL AIR INTAKE. DO NOT EXCEED 75'OF DEVELOPED ' ^ EF � LENGTH. IF THE LENGTH IS EXCEED UPSIZE THE DUCTWORK TO 12"Q). I CH� T �T) Fp ��FD � �F� 26x10 (28x12) I \I � O �O � V ` G � I..L 16 EXISTING FIREPLACE HOOD TO REMAIN. � TO FG1 � 18x10 (20x12) � �� I X � O 0 � � � �° �° � 6„� e � � � i� � '� �_' O 0 O17 AIRFLOW AND DISCHARGE AIR TEMPERATURE DUCT MOUNTED ° � Q - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12x10 (14x12) O L I `- � � � SENSORS. VERIFYWHICHSENSORISFACTORYSUPPLIEDPRIORTO I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - �� J N ' � ORDERWG. IF NONE, PROVIDE SENSORS AS INDICATED. J � � oxo 18x10 (20x12) � 18 PROVIDE 4" COMBUSTION AIR INTAKE FOR THE NEW FIREPLACE. ° � � � � O TERMINATE WITH A ROUND SEIHO LOUVER MIN. 12"ABOVE DECK. z � � _ VD W p E FG2 , VD 8FD �� � 19 ROUTE 8" O.D. FLUE UP THRU THE ROOF. OFFSET TO MAKE SPACE FOR v �FD O � O DUCTWORK. TERMINATE MIN. 3'ABOVE THE ROOF, 10' FROM A 390-S MECHANICAL AIR INTAKE AND PROPERTY LINE, AND 3'AWAY FROM 390-S 16x6 I ___—__ __ A 210-S GREAT ROOM �112'-4 3/4" A � � U NATURAL OPENING INTO THE BUILDWG. 36x4 16x6 Q � � 111'-4 3/4" - z � — I � � � _ N Q 4 - , � O � � 0 > � o � I BEDROOM 2 � BEDROOM 3 � � � 13'-0"X 11'-10" 12'-3" X 12'-6" e U iVICH"t FD � N �y N 00 EF \ ENTRY � I � 4 �" � 0 16 _ O � _ - - � _ - - � N � o� 320-S 320-S A 60x4 A 60x4 AEC PROJECT #: 13068.00 DATE: ISSUE: 08-06-13 PROGRESS UP 08-08-13 PERMIT SET Drawn By: Checked By: MZ TOC 2ND FLOOR HVAC NORTH PLAN 2ND FLOOR HVAC PLAN SCALE 1/4" = 1'-0" SCALE: 1/4"= 1'0" • 2 Of 2 m COPYRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS,INC. Code: 2012 International Building Code (IBC) ° 1. WALL ASSEMBLY-THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY E L E CT R I CAL L E G E I��W,� �F u,�r� By � Mondra on at 8:49 am, S@ 19, ZO�3 E L E CT R I CAL S P E C I F I CAT I O N S � SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL 9 p p�p 1 A U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND (NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT) � � SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: • -�+ 3 Q RECESSED OR SURFACE DOWNLIGHT ABBREVIATIONS �. G e n e ra I Re q u i re m e n ts � � (n � � A. STUDS-WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS MAX 2 HR FIRE RATED Q-I WALL MOUNTED LIGHT FIXTURE 15. SUPPORT (� � — N � AC -ABOVECOUNTER U N � ASSEMBLIES)OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 � AFF -ABOVE FINISHED FLOOR �• SCOPE: Furnish all materials and labor required to execute this work A. Support all electrical equipment independent of accessible ceilings as �- � O p�p MM) LUMBER SPACED 16 IN. (406 MM) OC WITH NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER END PLATES Aa RECESSED FLUOR.LIGHT FIXTURE AFG -ABOVE FINISHED GRADE as indicated on drawing and as specified, as necessary to complete the required by NEC. � � •� C..) � AL -ALUMINUM (q AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. 92 MM WIDE BY 1-3/8 IN. 35 MM DEEP Aa SURFACE FLUOR.LIGHT FIXTURE contract. Electrical work shall include, but not limited to, these major (n � � � � � � CU -COPPER f/� � CHANNELS SPACED MAX ZQ IN. �6'IO MM�OC. FIXTURE DESIGNATIONS: DESIG. -DESIGNATION items: 16. ELECTRICAL BOXES � � � p ti B. GYPSUM BOARD* - NOM 1/2 OR 5/8 IN. 13 OR 16 MM THICK, 4 FT. 122 CM WIDE WITH SQUARE UPPER CASE-FIXTURE TYPE EM -EMERGENCY O � O � O � � � � LOWER CASE-SWITCH DESIGNATION EMP -ENERGY MANAGEMENT PANEL A. Complete wiring system for new lighting and power as shown, A. At fire rated wall space electrical boxes at opposite sides of the wall .� L Q � OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER EWC -ELECTRIC WATER COOLER no less than 24" horizontal distance. U � p� TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES � SHADING ON FIXTURE INDICATES EMERG.BATTERY BACKUP GND -GROUND including new panelboards, new conduits, new wires, new wiring � d= � DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 26 IN. (660 MM). �� FLUORESCENT STRIP FIXTURE GFI -GROUND FAULT INTERRUPTER devices, new control devices, etc. for a complete lighting and B. When phone, TV&power receptacles are shown on plan next to each other. � � � � X O NF -NOT FUSED and power system. Locate respective receptacles next to each other on site with no more � ��. N � V �� TRACK LIGHT AS NOTED OR SCHEDULED NIC -NOT IN CONTRACT than 1��seperating cover plates. � � � �.L_ 2. THROUGH PENETRANT - ONE CONDUIT INSTALLED EITHER CONCENTRICALLY OR NL -NIGHTLIGHT �L +� � �+-� _ � WALL WASHER NTS -NOT TO SCALE a. Complete feeder(s) installation as required for new and/or � L, (n '� ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR � � V �O > Q-+-Q POLE-MOUNTED FIXTURE UG -UNDERGROUND electrical apparatus as shown on single line diagram and B, C at 6 W i ri n g Re q u i re m e n ts � J Q N i TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM) (POINT CONTACT)TO MAX 2 IN. (51 WP -WEATHER PROOF � POST(BOLLARD)FIXTURE drawings. N MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. x F M R -T R a N S F O R M E R � � (� � STEP LIGHT +18" -MOUNTING HEIGHT TO CENTERLINE � � � p� � � THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: b. Complete branch circuit wiring required for the connection of A. The cablin for voice and data must be continuous, home run, non-s liced, � , OF DEVICE AFF OR AFG g p � CEILING OR WALL MOUNTED EXIT LIGHT emer 211C �I htin and exit si ns to existin emer 211C stand � � � 0� � A. CONDUIT- NOM 6 IN. (152 MM) DIAM (OR SMALLER) STEEL CONDUIT OR NOM 4 IN. (102 MM)DIAM 9 Y �9 9 9 9 9 Y 500 Mhz or better category 6, 4 pair UTP as applicable. Acceptable V � EMERGENCY BATTERY LIGHTS FIRE ALARM SYSTEM � • �J,J �+� 1 B (OR SMALLER)STEEL ELECTRICAL METALLIC TUBING � by power system. manufacturers include: Berk-Tek, Belden, Lucent or equivalent. � � � � DUPLEX RECEPTACLE @ 18"UNLESS NOTED �FACP FIRE ALARM CONTROL PANEL � V J = O � 3. FILL VOID OR CAVITY MATERIAL* - CAULK OR SEALANT - MIN 5/8. 1-1/4,1-7/8 AND 2-1/2 IN. � DOUBLE DUPLEX RECEPTACLE @ 18��UNLESS NOTED 2. Complete provision, installation and connection of lighting fixtures, B. Data cable will be colored blue. Voice cable will be colored white. � r ANN FIRE ALARM ANNUNCIATOR PANEL 2XIt SI ns and lam S 8S S ecified and as shown on drawin S. � � � � 16, 32, 48 AND 64 MM THICKNESS OF CAULK FOR 1, 2, 3 AND 4 HR RATED ASSEMBLIES, O FLUSH FLOOR DUPLEX RECEPTACLE g p p g � W +-� � � Q FIRE ALARM PULL STATION L � RESPECTIVELY,APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. MIN 1/4 IN. (6 MM) � SPECIAL OUTLETAS NOTED 3. Fire alarm system will be by others. Coordinate connections to the C. The terminations at the station locations must be Category 6, T568B (AT&T) " � � ALARM HORN OR SPEAKER � DIAM BEAD OF CAULK APPLIED TO GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACT � DUPLEX RECEPTACLE HALF-SWITCHED @ 18^UNLESS NOTED . hood &duct detection modular RJ-45, 8 pin, 8 conductor, Hubbell, Leviton, or lucent or equivalent -�' U N O � p4� COMBINATION HORN/STROBE OR SPEAKER/STROBE acks, match face lates to ower, color coded for voice and data, match to V ' V LOCATION ON BOTH SIDES OF WALL. @ POP-UP RECEPTACLE � p p � •— � � •H THERMAL HEAT DETECTOR 4. Complete connection of HVAC/Plumbing motor(s),water heater(s), `+— O L THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING cable. Outlets will be securely held in place. � (a � � TELE-POWER POLE e ui ment, etc.furnish b mechanical -refer to both electrical and +-' � � � Max Pipe or Conduit F Rating T Rating OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED,AS SHOWN IN THE FOLLOWING TABLE. �� •� SMOKE/IONIZATION DETECTOR q p Y ._ V O � MULTI-OUTLET PLUG STRIP g p D. Wall mounted atch anels will be rovided. � � C O� — D�aM �n. cr,M) Hr Hr THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE •P PHOTOELECTRIC SMOKE DETECTOR and mechanical drawin for sco e and work and additinal infor- p p p � � J� JO JQ-I JUNCTION BOX IN FLOOR,CEILING OR IN WALL •H/P HEAT/PHOTOELECTRIC SMOKE DETECTOR mation. C.� � Q � 1 C25) 1 or 2 0+, 1 or 2 PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, � � AS TABULATED TO THE LEFT. 8 � COMPUTER/TELEPHONE OUTLET IN FLOOR OR WALL '(�g '(�R' DUCT DETECTOR E. All cables will be labeled with self-laminating labels at each cable end, at each � 1 C25) 3 or 4 3 or 4 I--B TELEVISION OUTLET QF SPRINKLER SYSTEM FLOW SWITCH 5. Provide grounding and bonding Facilities. patch panel location, and each wall/floor faceplate that has wiring installed. Q O 4 C102) 1 or Z 0 3M COMPANY- CP 25WB+ CAULK OR FB-3000 WT SEALANT, TELEPHONE BACKBOARD �-t- SPRINKLER SYSTEM TAMPER SWITCH Coordinate numbering scheme with owner. m CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING � 6. Complete all electrical demolition as required. O 6 t152� 3 or a 0 �- STROBE F. Provide plenum rated cable when required by article NEC 300-22. *BEARING THE UL CLASSIFICATION MARKING � CIRCUIT HOMERUN Op SMOKE/FIRE DAMPER CONNECTION � 12 c305� 1 or 2 0 7. Core drilling and patching of existing building structure required for - - - CONDUIT RUN BELOW FLOOR OR GRADE �l� REMOTE INDICATOR LIGHT electrical work. Core drilling shall follow Building Standard procedures G. All cable above the ceiling must be tied and properly supported with ] CONDUIT STUB-UP-CAP&MARK inde endent han ers. Cable"dra ed" across ceilin tiles is unacce table. In �'��t'���'��rr� P E N E T RAT I O N T H R O U G H A F I R E RAT E D WA L L SECURITY SYSTEM and contractor shall have written approvals from building owner prior p g p g p ���` � � ` LIGHT SWITCH AT 48°UNLESS NOTED the case of"hard"drywall ceilings, adequate support shall be accomplished �,s�;.,p,�� fi�-�'S '�,. � � suascRiPTS: to start of any work. ,� � � �.� DC CONTACT DOOR SWITCH IN JAMB OR HINGE i �` 2=2-POLE SWITCH where reasonably possible. �` �,�} �7 I�f,, '�'„ �, 3=3-WAY SWITCH � INTRUSION MOTION DETECTOR AS SPECIFIED,CORRIDOR/ROOM 8. Test of entire system and work. ��� � ��„ �r���:. NOT TO SCALE 4=4-WAY SWITCH C OR R M=MOTION-OPERATED SWITCH H. Route cables so as not to exceed 90 meters in length. Bidder will identify any ��C. � �� ROUTE WIRE AT CEILING PARALLEL OR K=KEY-OPERATED SWITCH �K KEY-OPERATED ACCESS SWITCH 9. Operating, Maintenance and identification instructions manuals, if cable runs exceeding 90 meters and provide solution to meet the 90 meter .: , � _ PERPENDICULAR TO STRUCTURE. SECURE TO=THERMAL OVERLOAD SWITCH �� SURVEILLANCE CAMERA anY• requirement. � � �� P=SWITCH WITH PILOT LIGHT � " � "�+ �: TO STRUCTURE AT 4' INTERVALS OR LESS. � � � � Y QD DIMMER SWITCH W/WATTAGE DISTRIBUTION EQUIPMENT SYMBOLS 10. PERMITS AND FEES: Obtain and pay for all necessary permits, inspec- �� i I. All wiring shall be protected from moving mechanical or physical contacts. � ,�, � Q PUSHBUTTON CONTROL STATION tions, examinations and fees or charges necessary for execution and ''r,. �c�. �� �:` —� DISCONNECT SWITCH Cabling shall be free from tension at both ends, as well as through out the ,�� �, �r� s �ti`� com letion of electrical work. -�. Pc PHOTOELECTRIC CELL p len th of the run. S lices and brid e ta s with cablin are strictl rohibited. �#� '• �(7fyp,L� ��` STUB UP TO ABOVE �� FUSES g p g p g y p ��� ��� rs TIME SWITCH ^ CIRCUIT BREAKER Wiring is to be run in cable tray and conduit where specified. �.z� ACCESSIBLE CEIWG 11. REGULATIONS AND CODES: QT THERMOSTAT AT 60"UNLESS NOTED —s�— CURRENT TRANSFORMER +80:AFF e J. All connections of twisted wiring shall be made in such a way as to minimize DIVISION 15 EQUIPMENT �� TRANSFORMER A. Applicable codes: National Electric Code (2008) � 0 FOOD SERVICE EQUIPMENT �� the extent in which each twisted pair is unraveled at the point of its physical M� METER Conform to the prevailing edition and amendments thereto of the Town of Vail Electrical Code, pertinent NFPA publications termination. No more than .5 inches of exposed untwisted pairs shall be COMMUNICATION SYSTEM � MAGNETIC MOTOR STARTER and to the requirements of Federal, State or other City agencies present at these locations. � STRUCTURED CABLE � DISCONNECTSWITCH DISTRIBUTION PANEL QS QS-� SPEAKER IN CEILING OR WALL having jurisdiction. V VOLUME CONTROL AT 60"UNLESS NOTED ' � PANELBOARD OR LOAD CENTER,FLUSH OR SURFACE MOUNTED K. Cable bends shall be no less than eight times the cable diameter or 1.00��. � +80"AFF � 12. SHOP DRAWINGS AND SUBMITTAL: Cables are to be ke t a minimum of 6"from ower lines, electric motors, M M MICROPHONE OUTLET IN FLOOR BOX OR WALL � SWITCHBOARD,MOTOR CONTROL CENTER OR DISTRIBUTION BOARD P P (2#CAT 6)3/4"C 0 � �T TRANSFORMER A. Contractor shall submit shop drawings for engineer review and approval. fluorescent fixtures or heat generating devices. PLENUM RATED WIRE OC -i CALL-IN SWITCH I I I REQUIRED OO PROGRAM BELL �I�� GROUND L. All cable han ers shall be no more than 48"a art. Contractor shall be W 0 CIRCUIT BREAKER B. Shop drawing submittal shall include: 9 P QI INTERCOM familiar and install in accordance with all applicable codes and standards, � � #6 CU G QQ MOTOR OUTLET 1. Lighting fixtures. Q aocK including NEC, EIA/TIA 568,569 and 606, and federal, state and local codes. � P PULLWIRE 4��C ATS AUTOMATIC TRANSFER SWITCH 2. Panelboard(s). � � QA AMPLIFIER � Care must be taken to ensure cables are not kinked, bent beyond limit, (1) RJ-11 &(1) RJ-45 13. CONDUIT AND WIRE: overloaded, over-cinched, crushed, improperly untwisted, etc. � MAIN TELE/DATA SINGLE GANG A. CONDUCTOR SIZES AND TYPES: Use only copper wire, 600 volt M. No ex osed wirin will be acce ted unless a roved in writin b the O ROOM i BOX AT 18 AFF insulation, stranded in sizes#8 and larger, solid in sizes#10 and p g p pp g y O O � � engineer. Cabling shall be in the wall, above the ceiling or where exposed, � Q COLD WATER PIPE T E L E P H O N E/ smaller. Control wiring shall be#14, stranded. In sizes#1 and enclosed within cable trays, raceways or conduit, as specified. � � T E L E P H O N E O N E� smaller, use types TW, THHN or THW. In sizes larger than#1, use � � THW or XHHW. Use type THHN for wires entering or passing N. All cabling shall be bundled and properly secured and terminated. J � C O M P U T E R R O U G H I N through fluorescent lighting fixtures. � L I N E D I AG RA M B. MC cable permitted per local codes. O. The warranty set forth for this system shall consist of a full three (3)years � O from the date of project completion. The contractor warrants the system to be � NO SCALE 14. ELECTRICAL DEVICES free of defects of workmanship or products and will inspect and repair the � J A. Convenience receptacles will be 20 amp, commercial grade system during this warranty period at no additional cost to the owner. The � � O decora style. Finish per owner or architect. warranty period shall begin at the point of system acceptance or beneficial � QUANTITIES PER FLOOR PLANS use, whichever comes later. � � r , B. Light switches will be 20 amp, commercial grade, Q v decora style. Finish per owner or architect. C. Dimming switches will be a minimum of 600w or as noted. � � TYPICAL 8'0" CEILING Provide decora style,finish per owner or architect. Z — PANEL D. All mountin hei hts will conform to ADA uidelines. T pical rece tacle � � 9 9 9 Y p � ��i \ � � ELEV heights will be +18"AFF and switch heights will be+46"AFF O > � � COAX RECEPTACLE IN � unless noted otherwise. W DOUBLE GANG BOX @ 18"A.F.F. 20 HP � UNLESS NOTED ELEVATOR E. Provide GFI type receptacles at kitchens, bathrooms, � garages, exterior etc. as required by code. � (RG6 QUAD SHIELDED CABLES)3/4"C M PANEL M MAIN CIRCUIT BREAKER& CONDUIT STUBBED TO ACCESSIBLE COND02"C2" NEW WORK IS w � BRANCH CIRCUIT BREAKERS CEILING, PLENUM RATED WIRE <10,000 AFC CLOUDED. EXTEND MAXIMUM MOUNTING HEIGHT RAN TO BACK BOARD FEEDERS AND SET � IS 48", MINIMUM IS 18". (3#10 CU, 1 #10 CUG) 1/2"C PANELS CONDO AND � STRUCTURED CABLE COND02 IN LOCATIONS � � D T 2"C PVC WITH PULLWIRE DISTRIBUTION PANEL 4#1 CU, 1 #6 CUG) 1-1/2"C— (3#1 CU, 1 #8 CUG) 1-1/4"C SHOWN. PROVIDE � BURIED 20" BELOW GRADE � CIRCUIT BREAKERS AS o CATV SCHEDULED, REUSE CO " PEDESTAL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL EXISTING BREAKERS � HOUSE JDL JDR RETAIL1 RETAIL2 RETAIL3 CONDO R1 R2 AS FIELD CONDITIONS � °O o -� � IT `� � #6 cu � �00/2 AEC PROJECT #: 13068.00 � � �O TU � � 3%— � � 110/3 200/3 100/2 150/2 DATE: ISSUE: METALLIC COLDWATER PIPE � FINISHED FLOOR 17,166 AFC 12,869 AFC 37,194 AFC 13,081 AFC 12,383 AFC 14,996 AFC <10,000 AFC <10,000 AFC 08-06-13 PROGRESS � CABLE TV ONE LINE DIAGRAM (4#3/0 CU, 1 #4 CUG)3"C OR(4#250 MCM AL, 1 #2 ALG)3"c 08-08-13 PERMIT SET TY P I CA L D E V I C E NO SCALE (3#1/0 CU, 1 #6 CUG) 1-1/2"C— OR(3#3/0 AL, 1 #4 ALG)2"C M O U NTI N G H E I G HTS (3#1 CU, 1 #6 CUG) 1-1/4���- OR (3#2/0 AL, 1 #4 ALG)2"C NOT TO SCALE G E N E RAL N OT E S AL L S H E ETS (3#4 CU, 1 #8 CUG) 1��C— Drawn By: Checked By: NOTES: CTL SOH 1. HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE. THE ELECTRICAL CONTRACTOR WILL PROVIDE A WALK THROUGH WITH THE OWNER/ARCHITECT PRIOR TO FINAL ROUGHIN AS FOLLOWS: — — — — — — — — — — — — — — — — — — — — 2. DEVICES ABOVE DOORS SHALL BE CENTERED BETWEEN •CONFIRM ALL LOCATIONS FOR LIGHT SWITCHES,ADD THREE WAYS ELECTRICAL TOP OF DOOR TRIM AND CEILING LINE. IF FOUND NECESSARY. � 200/3 Q 200/3 � 125/3 0 125/3 � 125/3 Q 200/3 Q 100/2 Q 150/2 •REVIEW RECEPTACLE LOCATIONS, MOVE AS REQUIRED. PROVIDE SPECS 3. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS UNIT PRICING IF ADDITIONAL RECEPTACLES ARE REQUIRED. 99,500 AFC 62,065 AFCI I AND NOTED ON ELECTRICAL FLOOR PLANS SHALL GOVERN •REVIEW RECEPTACLE LOCATIONS AT COUNTERS AND CONFIRM � OVER THOSE SHOWN ABOVE. IF THOSE RECEPTACLES SHOULD BE ABOVE COUNTER OR BELOW. 3[(4#400 MCM AL)3"C] � 800/3 � MOVE AS REQUIRED. LEGEND lX. 4. FOR CEILING HEIGHTS HIGHER THAN 7'2", INSTALL FIRE ALARM IN GENERAL CONFIRM POWER AND LIGHTING REQUIREMENTS. THE NOTIFICATION AUDIO AND VISUAL APPLIANCES AT 80"AFF ELECTRICIAN SHOULD BE PREPARED TO REWORK SOME DEVICE LOCATIONS. UTILITY DETAILS OTHERWISE INSTALL AT 6" BELOW CEILING. SIGNIFICANT REWORK SHOULD BE FLAGGED AND UNIT PRICING TRANSFORMER 5. MOUNTING HEIGHTS PER IBC 2003 AND ADA CODES APPROVED PRI RTIO PROCEEDING ATION FOR ADDITIONAL COSTS PAD MOUNTED MAI N DISTRI BUTION CENTER ��M DC�� NO SCALE 800A, 120/208V, 3P, 4W 65kAIC ELECTRICAL ONE-LINE DIAGRAM - FOR REFERENCE ONLY • NO SCALE 1 Of 3 �COPYRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS,INC. 0 N � PANEL CONDO � PROJECT:BRIDGE STREET BUILDING ENGINEER: CTL (I� � PROJECT#:27838 VOLTAGE: 120/208V,3P,4W '�'� '� MOUNTING:SURFACE MAINS: 200A MCB � (n � (� � TYPE:SQUARE D QO AIC: 22K � V � 0 (V PHASE PHASE -F-+ � Lf� DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION � .� � U � '^ Q) '� 00 EXTERIOR RECS 540 20 1 1 2 1 20 1191 RECEPTION LIGHTING Reviewed for Code Compliance v, � fn � � GREAT ROOM REC 3 540 20 1 3 4 1 20 703 GREAT RM E LIGHTING � � � � ti GREAT ROOM REC(3) 540 20 1 5 6 1 20 1010 GREAT RM W LIGHTING Code: 2012 International Buildin Code �BCi `~ GREAT ROOM REC(4) 720 20 1 7 8 1 20 820 TOPO GALLERY LIGHTING g (O � O a O REFRIGERATOR 1000 20 1 9 10 1 20 1025 BATH&HALL LIGHTING f��]� p F Up r� By J Mondragon at 8:49 am, Sep 19, 2013 V � � O7 HOOD 1000 20 1 11 12 1 20 810 CONF/JANLIGHTING 7�J % o f a l l l i g h t i n g s h a l l b e h i g h Q � � � DISPOSAL 1000 20 1 13 14 1 20 444 COPY/POSTLIGHTING � � � X 0 efficacy �}. c� DISHWASHER 1000 20 1 15 16 1 20 1036 ME CANS � � � � � V KITCHEN COUNTER REC(3) 540 20 1 17 18 1 20 400 ME#1&2 TASK LIGHTING �� ;� � ++ � KITCHEN COUNTER REC(3) 540 20 1 19 20 1 20 600 ME#3,4&5 TASK LIGHTING n' � U � •(� KITCHEN COUNTER REC(3) 540 20 1 21 22 1 20 478 DOS,SYS&HVAC LIGHTING /r�'�� RANGE 2600 40 2 23 24 1 20 142 EXHAUST FAN#1 W J Q N O > � � � � � " 2600 25 26 2 100 4040 PANEL COND02"C2" � � STEAMSHOWER 3750 50 2 27 28 4040 " �� � � � " 3750 29 30 3 20 500 FC-1 U Q C� 00 DRYER 2500 30 2 31 32 500 � . DUCT HEATER Z500 6000 60 3 35 36 3 20 500 500 FC-2 � V J = O � W �� � � w � � � � 6000 37 38 500 � 6000 39 40 500 0 0 " LOAD CALCULATION SUMMARY � � '+"' U � O C � '� � 00 O CALCULATED POWER FACTOR: O � Q 0.99 � V � CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS � � C � � LIGHTING 8517 25 10646 31 U � Q � � RECEPTACLES 16040 44 13020 36 L MECHANICAL 3142 10 3517 11 � X KITCHEN 35700 99 23205 64 0 TOTAL 63399 178 50388 143 CON�0-24 m � PANEL COND02 "C2" EF � PROJECT:BRIDGE STREET BUILDING ENGINEER: CTL 1 M PROJECT#:27838 VOLTAGE: 120/208V,1P,4W ��Y �'t�-� MOUNTWG SURFACE MAINS: 100A MLO ��i��,��t��t�� ?• TYPE:SQUARE D QO AIC: 14K *-;,}� `" �' # �� �� ���;rs � ,. PHASE PHASE � � A� � � � �y C'} H,:�� '��.,- DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION GFI �� }p ' �(�v �� r� �`� BEDROOM 1 REC 4 720 20 1 1 2 1 20 180 BATHRM 2 REC 1 /' �J � x '`-' *- ,.; BATHRM 1 REC 1 180 20 1 3 4 1 20 720 BEDROOM 2 REC 4 +'� AC � ' d + : MSTR BATH JACUZZI 1000 20 1 5 6 1 20 900 BEDROOM 3 REC(5) GF '� � G � � [l7 �" � MSTR BATH REC(2) 360 20 1 7 8 1 20 360 LAUNDRYROOM REC(2) r � �c w MASTER REC(5) 1260 900 20 1 11 10 1 20 1500 0 SPACE R 50A2P y t-r"� =�s� N��`%,}��� SPARE 0 20 1 13 14 0 SPACE C� ��-27,29 �{ "-� �1f'�AL � �` �y� SPACE 0 15 16 0 SPACE � STEAM �'t�r�� ��.�} SHOWER ���I- SPACE 0 17 18 0 SPACE C2_] SPACE 0 19 20 0 SPACE SPACE 0 21 22 0 SPACE > SPACE 0 23 24 0 SPACE JACUZ I SPACE 0 27 28 0 SPACE - GFI � E CONDO-30,32 34 SPACE O 0 31 32 O 0 SPACE I �E� 1C (1) (E� CK WP M � �(EI)� � C2-5 w _ �E� C2-3 C2-9 � LOAD CALCULATION SUMMARY � � CALCULATED POWER FACTOR: /�C � � �.00 O F� � , C2-11 � CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS (� � O LIGHTING 0 0 0 0 `H' \ O O RECEPTACLES 8080 39 8080 39 � \ - � Q MECHANICAL 0 0 0 0 i� � KITCHEN 0 0 0 0 � � � TOTAL 8080 39 8080 39 C2-1� � � WP(E) C2_� I � CONDO-35,37,39 n/ GFI � L 60A3P DUCT HEATER � O T1 ..... _... .. �b,',,_ � —� M � REF � AC AC J AC GFI GFI N � W O GFI CONDO-11 � CONDO-23,25 HOOD CONDO-19 � U E� 20A1P � RANGE CONDO-31,33 Q +78" COND -9 40A2P Q(E) CONDO-13 ONDO-15 C2-12 FC CONDO-36,38,40 � � J � �E) Z � � AC GFI C2- C2-1 C2-10 �2 . � GF � Q CONDO-7 AC AC� DISP CONDO-21 PANELS M CONDO-17 GFI GFI" � CONDO &C2 �E� � � � �= RELOCAI�E � � � AND REWORK � � � — ] � � C2-6 ' � � � . . N C2-4 �, CONDO-3 � � FB �� CONDO-5 AEC PROJECT #: 13068.00 �E DATE: ISSUE: �j +96" C2-8 08-06-13 PROGRESS FP� (E) �E� � 08-08-13 PERMIT SET O • � � GFI �(E) (E�G P N M I I N I Drawn By: Checked By: CTL SOH 2ND LEVEL WP POWER & GFI �(E) SYSTEMS PLAN NORTH SCALE: 1/4" = 1'-0" 2ND LEVEL POWER & SYSTEMS PLAN SCALE: 1/4" = 1'0" • 2 of 3 �COPYRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS,INC. 0 N � r � GHTNG � XTURE SCHEDU �E �, °° � � � MARK DESCRIPTION MANUFACTURER CATALOG NUMBER LAMP NOTES � N � � N -�--+ U N � Ln A ADJUSTABLE RECESSED CAN LUCIFER DL2RZP-CTM PR❑VIDE LENS AT SH❑WERS � � p U o0 � •� o0 B FIXED RECESSED CAN LUCIFER LED PR�VIDE LENS AT SH❑WERS � � cn �� C R❑UND ADJUSTABLE EYEBALL LUCIFER DL7 O .�o Q o F FLU❑RESCENT CLOSET LIGHT U � �' d=� � � � a� � XO ID DEC❑RATIVE FIXTURE T❑ BE .� �.a � � V SPECIFIED BY INTERI❑R DESIGNER � � v � (� N ;J V d' N � Q N IECC 2009 CALCULATION � � � °� 00 � .� � p co 0o c6 Incandescent Fixtures High Efficacy Fixtures � -� W �� � Fixture Fixture w V J 2 O � Type Lamp Type Quantity Type Lamp Type Quantity � LN � � � � Reviewed for Code Compliance ID INCANDESCENT 9 B LED 25 � ' � Code: 2012 International Building Code (IBC) A INCANDESCENT 25 F FLUORESCENT 2 � ca � r N f��� �� �q�� By J Mondragon at 8:49 am, Sep 19, 2013 C INCANDESCENT �o U LED 22 U '� � 00 O N m � �° Q :� � O � � crn� � � Q � � � 75 % per 2012 Q x IECC � m TO � � Incandescent Total: 44 High-Efficacy Total: 49 Percent High-E icacy: . o be minimum of 50%) ����trrcu�� EXISTING LIGHTING FIXTURES REMAINING IN PLACE ARE ���� [)� �E{;�r ��fi, EXEMPT FROM THIS CALCULATION PER IECC `�j "<`�` `S r ':`' ����..�7 �� �'`,��'� r�: „ w � =. I � LT.05 ��`�' � �� I * � r � A ID � �E� LT.05 � � � � � �; •- "� (C _,ti A � A �E� LT.05 ';-��r� s.; �� A TO �E) �E� ����`�#�����NAL�����;'l,� A SHOWER �rx���-'' A LIGHTS A �ATO �E� DIMSW A D A � B � DECK I �' �' LT.O1 B B TO (E) EF A (E) � � , A z W D B �E) A � � A � ID ' O � Q O 3 A � Q � � BALCONY � �- � a � N � � � � _ ,-,-t� � D D � � � O p RELOCATE SWITCHES W � � � � � � p a,b,c,d,e TO HERE � � O CONDO-6 � SWITCH a B D � (E) �E� A A A A A 3 B B 4 B 3 U U > ^ D Q p 3 a � � � O �E� �E)A ° B B .. N Q c A A A A A 3 � E u p O � ( ) � � � � � � � � � B B � � � � � ID ID ID �- ID B B � _ � A A E A A\C/ � O� .. � E � ) (E) � � LT.04 LT.04 �E�•05B A�E� ,,�E) LT.05F TO � CONDO-6 CONDO-2 �E� F EF � � ,' � M B E� �E SWITCH d � VV L T.05B L T.05F N (E) �E� �E� (E) (E) (E) (E) �E� ff�J v B , . . , , CONDO-4 CONDO-4 L, SWITCH b SWITCH e LT.05A L 5F B B � (E) SW TC�H c � � �E� (E) � B " (E) TO \ � (E) (E) (E) yyy��� AEC PROJECT #: 13068.00 EF I CONDO-4 A �E� � � DATE: ISSUE: \ B B D B , 08-06-13 PROGRESS � (E) �E)A �E) �E) (E) �E)A p 08-08-13 PERMIT SET � ID D3 � � _ II II III� Drawn By: Checked By: CTL SOH 2ND LEVEL �P LIGHTING PLAN NORTH SCALE: 1/4" = 1'-0" 2ND LEVEL LIGHTING POWER PLAN SCALE: 1/4" = 1'0" • 3 of 3 �COPYRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS,INC. 0 N � � P L U M B I N G L E G E N D ARE NOT NECES9ARILYOU ED. N LEGEND pp PLUMBING SPECIFICATIONS: � o "I. GENERAL: °°� DOMESTIC COLD WATER -O PIPE RISER � (n (jj � COUNTERTOP OR FLOOR ' . u.�.����-� �onnESTic HorwaTER �. PIPE DROP � � N L N a.FURNISH ALL LABOR, SUPERVISION, MATERIALS, EQUIPMENT AND FACILITIES NECESSARY TO FURNISH, FABRICATE, DELIVER, STORE AND INSTALL ALL WORK NOTED ON THE DRAWINGS CONTINUE PER ���n�����mm � V � O � AND/OR SPECIFIED HEREIN. KEEP AS HIGH AS PLANS °-��� DOMESTIC HOT WATER RECIRC. � PIPE TAKEOFF(FROM BOTTOM OF MAIN) � � O U O�O b. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL WORK NECESSARY TO MAKE A COMPLETE SYSTEM WHETHER OR NOT SUCH DETAILS ARE MENTIONED IN THESE SPECIFICATIONS OR POSSIBLE ABOVE PTRP WASTE ABOVE GRADE -O- PIPE TAKEOFF(FROM TOP OF MAIN) � '� op SHOWN ON THE PLANS, BUT WHICH ARE OBVIOUSLY NECESSARY TO MAKE A COMPLETE SYSTEM, EXCEPTING ONLY THOSE PORTIONS THAT ARE SPECIFICALLY MENTIONED HEREIN OR SEE PLAN FOR -��w� WASTE BELOW GRADE � PIPE END CAP � � � � � PLAINLY MARKED ON THE ACCOMPANYING DRAWINGS AS BEING INSTALLED UNDER ANOTHER SECTION OF THE SPECIFICATIONS. CLEANOUT TYP. VENT SIZE -cw- GREASE WASTE ABOVE GRADE PIPE CONTINUATION � � � � ~ � O � O � O ��-GW-��n- GREASE WASTE BELOW GRADE PIPE EXPANSION GUIDE �� L Q ti 2.WORKMANSHIP: PLUMBING -iw- iN�iRECTwasTE -�IF- PIPE UNION � � � d- � � a.THE WORK SHALL BE ACCOMPLISHED IN A THOROUGH AND WORKMAN-LIKE MANNER SATISFACTORY TO AND MEETING THE APPROVAL OF THE OWNER AND ARCHITECT. APPLIANCE T�1 � � -G- GAS �� PIPE ANCHOR V� � N N X� O -MPG- MEDIUM PRESSURE NATURAL GAS FLEXIBLE PIPE CONNECTION � 3. MATERIALS: VARIES � � � lL _ VENT -� PIPE EXPANSION JOINT •L � � � '� a. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND THE BEST OF THEIR RESPECTIVE KIND, FREE FROM ALL DEFECTS AND OF THE MAKE AND QUALITY SPECIFIED. ^' � L- (n 4.SITE INSPECTION: -C- CONDENSATE DRAIN � � POINT OF NEW CONNECTION W^1 �Q N FLOOR OR CEILING CO CLEAN OUT � � PLUG VALVE W J U � N > a.CONTRACTOR SHALL VISIT THE SITE OF WORK PRIOR TO SUBMISSION OF HIS BID AND THOROUGHLY FAMILIARIZE HIMSELF WITH THE WORKING CONDITIONS&EXACT NATURE OF THE WORK. �- wco WALL CLEAN OUT I� -I/H- CHECK VALVE � � � � � � b. SUBMISSION OF A BID ACKNOWLEDGES FULL RESPONSIBILITY FOR FURNISHING A COMPLETE AND FUNCTIONAL SYSTEM. SLOPE Fco FLOOR CLEAN OUT � �,.,'� BALL VALVE .� � � �p ap CCf c. NO CHANGES IN CONTRACT WILL BE MADE TO ACCOMMODATE OR ALLOW EXTRA FUNDS FOR ANY OMISSION WHICH RESULTS FROM A FAILURE TO THOROUGHLY MAKE THE EXAMINATION. coTC CLEAN OUT TO GRADE � ��� BALANCING VALVE � •V W �� . DE AND PERMIT : CONTINUE WASTE L f` � 5 CO S S �� PER PLANS (E) EXISTING �- FLOW REGULATOR VALVE � V J = O � SLOPE (N) NEW -I\I- BUTTERFLY VALVE � � a. ALL PLUMBING EQUIPMENT, INSTALLATION, ETC., SHALL CONFORM TO THE 2012 INTERNATIONAL PLUMBING CODE (IPC), 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)AND vTR VENT THROUGH ROOF � w � � � ORDINANCES AS INTERPRETED BY THE TOWN OF VAIL BUILDING DEPARTMENT. -�- PRESSURE RE�uaN�va�vE L � b. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS. ISLAN D VENT DIAGRAM UTP UP THROUGH ROOF � 2_WAY CONTROLVALVE �"' U N O � c. COPIES OF ALL PERMITS AND INSPECTION REPORTS SHALL BE SUBMITTED TO THE ARCHITECT. U �� .v o0 0 O SCALE DN DOWN 3-WAY CONTROL VALVE � (�j � � Q 6. AS-BUILTS: HB HOSE BIB -}+ a--� � � � a.CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS-BUILT DOCUMENTS WITH ALL CHANGES NOTED THEREON AT THE COMPLETION OF THE PROJECT AND PRIOR TO FINAL ACCEPTANCE FPHB FREEZE PROTECTED 4-WAY CONTROL VALVE � � � aj� AND PAYMENT. �Q HOSE BIB -� � � a � � PP PURGE PORT 1 ��l DIFFERENTIAL BYPASS VALVE L 7. GUARANTEE: ��� � FS FLOOR SINK � Q X a.CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL LABOR AND MATERIALS ON ALL WORK AGAINST DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER � STRAINER m COMPLETION. � PIPE CAP �"�] _ NATURAL GAS PRESSURE REGULATOR O 11F-`+ s. suanniTTa�s: Reviewed for Code Compliance PTRAP OC � AIR VENT � a.CATALOG INFORMATION AND CUTS OF ALL EQUIPMENT AND DEVICES SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW(SIX COPIES OF EACH). COCI@: 2012 International Buildin Code IBC iP INLWE PUMP ,rYr,�u�r 9. COORDINATION: g ( ) AND�SCR W LLCOVER � � PRESSURE-TEMP.TAP ����tt�� �fi� �� �,,�- a.THE DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW SCOPE. TDVIIIV OF VAI� By � M011CI1"agOfl 8t H:4g 81"Yl, Sep 19, ZO�3 P.C. PLUMBING CONTRACTOR -0 PRESSURE�au�E ;b`� '+r� '�`�1` `'�'.�. M.C. MECHANICAL CONTRACTOR �+ b. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES TO PROVIDE BEST ARRANGEMENT OF ALL DUCTS, PIPES, CONDUIT, ETC. - � v � � ' '`�- = - � EXTERIOR WALL E.C. ELECTRICAL CONTRACTOR -� THERMOMETER �,�.� � �'^ � �* 10. CUTTING AND PATCHING: PLUGGED TEE WITH A.H.J. AUTHORITY HAVING JURISDICTION � �" _ S `" `� a. ALL CUTTING AND PATCHING REQUIRED OF THE STRUCTURE NEW OR EXISTING SHALL BE PROVIDED UNDER OTHER SECTIONS OF THE WORK. � � * � ' ,� � ) , CLEAN OUT � � , b. PROVIDE NECESSARY REQUIREMENTS TO THE PROJECT SUPERINTENDENT. - � � �,j ¢ ,�' c. X-RAY SLABS PRIOR TO CORING. - . ° GAS SIZING SCHEDULE v� � � FLOOR LINE y'*'�, �� ��, r�,�4� 11. CLEANUP: � �,� ��(��q��c. ��> a.UPON COMPLETION OF THE WORK UNDER THIS SECTION, THE CONTRACTOR SHALL REMOVE ALL SURPLUS MATERIALS, EQUIPMENT AND DEBRIS INCIDENTAL TO THIS WORK AND LEAVE THE ��`` �'y} v v JOB NAME: RITZ CARLTON CONVESRION PROJECT ELEVATION: 8150 A.S.L. ��� PREMI ES CLEAN AND RDERLY. o o v � v 0 0 °o v o 0 o e� o�o o JOB NUMBER: 13068 GAS VALUE: 808 BTU/CF 12. PLUMBING IDENTIFICATION DATE: 8/7/2013 GAS COMPANY: XCEL ENERGY a.EQUIPMENT NAMEPLATES: METAL, WITH DATA ENGRAVED OR STAMPED, FOR PERMANENT ATTACHMENT ON EQUIPMENT. b. PIPE MARKERS: PREPRINTED, COLOR CODED, WITH LETTERING INDICATING SERVICE,AND SHOWING DIRECTION OF FLOW. %" C.I. BEND PREPARED BY: MARTIN ZOUREK MAX PIPE RUN: 90 L.P. c. VALVE TAGS: STAMPED OR ENGRAVED WITH 1/4" LETTERS FOR PIPING SYSTEM ABBREVIATION AND 1/2" NUMBERS,WITH NUMBERING SCHEME. PROVIDE 5/32" HOLE FOR FASTENER. d. VALVE TAG SCHEDULE: PREPARE A VALVE TAG SCHEDULE TO BE SUBMITTED TO THE MAINTENANCE ENGINEER FOR RECORD. '' BALANCE OF PIPING - M.P. � SAME AS CLEANOUT 13. PIPE INSULATION: TO GRADE � a.DOMESTIC WATER PIPING INSULATION SHALL HAVE A THERMAL CONDUCTIVITY LESS THAN OR EQUAL TO 0.27 BTU-IN/HR-FT2-OF. TAG DESCRIPTION BTUH TABLE CFH SIZE b. HOT& COLD WATER SUPPLY PIPING (EXCEPT RUN OUTS 12 FT. OR SHORTER TO INDIVIDUAL FIXTURES)SHALL BE INSULATED AS FOLLOWS: BBQ-1 gg(� 30,000 37.1 1/2" PIPE SIZE (IN.) INSULATION THICKNESS (IN.) WALL CLEANOUT DIAGRAM ggQ_1 ggQ 30,000 37.1 1/2" w 1/2", 3/4"& 1" 1' NO SCALE z 1 1/4"THROUGH 6" 1 1/2" BBQ-1 ggQ 30,000 37.1 1/2" � c. NO HOT OR COLD WATER PIPING SHALL BE ROUTED IN EXTERIOR WALLS UNLESS PROPERLY INSULATED. FP-1 (E) FIRE PLACE 150,000 185.6 1/2" � d.CONDENSATE PIPING SHALL BE INSULATED WITH 3/8" FOAM PLASTIC. O FP-2 FIRE PLACE 38,000 47.0 1/2" O O 14. PIPING: RANGE RANGE/OVEN 780,000 965.3 1/2" � Q DRYER DRYER 35,000 43.3 1/2" � � a. WASTE AND VENT PIPING: � � a i. SHALL BE STANDARD WEIGHT CAST IRON HUB LESS TYPE. � �/ ii. UNDERGROUND PIPING CAN ALSO BE SCHEDULE 40 PVC. LL iii.VENT PIPING IN RETURN AIR CEILING PLENUMS SHALL BE ABS OR COPPER PIPING. MAIN-TOTAL 1,093,000 SCHEDULE 40 0.5 PSI-0.5" WC 1,352.7 1-1/2" � � O b. WATER PIPING: NOTE: IXISTING GAS LINES AND GAS SERVICE WAS SIZED ADEQUATE ENOUGH TO UITILIZE GAS APPLIANCE ADDITIONS i. SHALL BE TYPE"L" COPPER HARD DRAWN WITH WROUGHT COPPER FITTINGS. � ii. JOINTS SHALL BE SOLDERED WITH 95-5 OR SILVER SOLDER. � W O iii.WATER PIPING 1 1/4" &SMALLER CAN ALSO BE WIRSBO AQUAPEX APR, REHAU RAUPEX OR EQUIVILANT-PROVIDE DEDUCT ALTERNATE PRICING. � c. CONDENSATE PIPING SHALL BE TYPE "M"�oPPER W�TH So�oER�o�NTS. P L U MB I N G F I XT U R E C O N N E C T I O N S C H E D U L E U d.NATURAL GAS PIPING: U > i. 2"AND SMALLER SHALL BE THREADED STANDARD WEIGHT SCHEDULE 40 BLACK STEEL PIPE WITH SCREWED MALLEABLE IRON FITTINGS. COLD HOT Q � MARK MANUCTURER & MODEL NO DESCRIPTION WASTE VENT REMARKS ii. PIPING 2 1/2"AND LARGER SHALL BE WELDED. WATER WATER � � � iii.ALL OUTDOOR EXPOSED PIPING SHALL BE PAINTED WITH OUTDOOR ENAMEL. � � iv.REGULATOR VENTING SHALL BE NO LONGER THAN MANUFACTURER'S RECOMMENDATION,ALUMINUM, VENTED TO THE OUTDOORS,AND A MINIMUM OF 3' FROM ANY OPENING INTO BUILDING L-1 LAVATORY PRIVATE 1-1/2" 1-1/2" 1/2" 1/2" - � AND 6' FROM ANY MECHANICAL INTAKE AND 1' FROM ANY ELECTRICAL EQUIPMENT. KS-1 KITCHEN SINK 2" 1-1/2" 1/2" 1/2" - O > � 15. EACH PLUMBING VENT SHALL TERMINATE NOT LESS THAN TEN FEET FROM ANY MECHANICAL INTAKE AND AT LEAST THREE FEET FROM ANY OPENING INTO THE BUILDING. WG1 WATER CLOSEf 3" 2" 1/2" - FLUSH TANK PRNATE � � 16. CLEAN-OUTS SHALL BE INSTALLED AS PER 2012 IPC SECTION 708. DW-1 PLUMBING FIXTURE SPECIFICATIONS&HARDWARE SELECTION DISHWASHER I.W. - - 1/2" REFERENCE MANUFACTURER'S MANUAL FOR CONNECTION CONNECT VIA AIR GAP TO KffCHEN SINK � TO BE BY THE INTERIOR DESIGNER. FIXTURE ALLOWANCE � 17. PROTECT ROOF RECEPTOR ON ROOF FROM RAIN WATER BY ELEVATING THE RIM 2 '/2" INCHES ABOVE ROOF SURFACE. BT-� NOTTO IXC�THEESTABLISHEDBUDGET. BATHTUB 2" 1-1/2" 3/4" 3/4" - � 18. PROVIDE WATERTIGHT FLASHING WHEREVER PIPES PASS THRU EXTERIOR WALLS, ROOF AND FLOORS. SH-1 SHOWER 2" 1 1/2" 3/4" 3/4" PROVIDEFLOORTRENCH DR,41N FORTHESHOWERPERARCHITECTUR,4L SPECIFICATION � IM-1 ICEMAKER - - 1/2" - REFERENCE MANUFACTURER'S MANUAL FOR CONNECTION � 19. PENETRATION IN WALLS REQUIRING PROTECTED OPENINGS SHALL BE FIRE-STOPPED. FIRE-STOPPING SHALL BE AN APPROVED MATERIAL SECURELY INSTALLED AND CAPABLE OF MAINTAINING ITS INTEGRITY WHEN SUBJECTED TO TEST TEMPERATURE FOR SPECIFIC WALL OR PARTITION. CWB-1 CLOTHESWASHERBOX 2" 2" 3/4" 3/4" 2"TRAPSHALL BECONNECTEDT03"COMMON LINE 20. PROVIDE FELT WITH METAL BACKING VIBRATION ISOLATION SLEEVES OR PADS AT ALL PIPE HANGERS OR SUPPORTS AND ALL POINTS WHERE PIPING COMES IN CONTACT WITH ANY PORTION FCO ZURN Z1454 FLOOR CLEAN OUT VARIES - _ _ P.C.TO PROVIDE CLEANOUTS AT EACH CHANGE OF DIRECTION OF THE HORIZONTAL WASTE LINES GREATERTHAN 45° OF THE STRUCTURE. APPLIES TO ALL WATER AND WASTE PIPING. WITHIN 4o FT OF DEVELOPED LENGTH oF THE DR,4INAGE PIPING.VERIFY ExACT LoCATION oF CLEANOUTS IN FIE1D. 21. LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE. CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DEPTHS OF UTILITIES PRIOR TO STARTING WORK OF THIS SECTION. MAKE WCO ZURN Z1446 WALL CLEAN OUT VARIES - _ _ P.C.TO PROVIDE CLEANOUTS AT EACH CHANGE OF DIRECTION OF THE HORIZONTAL WASTE LINES GREATEFt THAN 45° REQUIRED ADJUSTMENTS TO CONNECT TO EXISTING UTILITIES. IF INDICATED POINTS OF CONNECTION CANNOT BE MADE TO UTILITIES AS FOUND, THE CONTRACTOR SHALL, BEFORE WITHIN 40 FT OF DEVELOPED LENGTH OF THE DRAINAGE PIPING.VERIFY EXACT LOCATION OF CLEANOUTS IN FIELD. CONTINUING, NOTIFY THE ARCHITECT PRIOR TO INSTALLING ANY WORK WHICH MAY BE AFFECTED. AEC PROJECT #: 13068.00 22. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AVAILABLE SPACES FOR INSTALLING THE WORK. DOMEST I C WAT E R S IZI N G C HART DATE: ISSUE: 23. VALVES SHALL BE NIBCO, JENKINS, WALWORTH, STOCKHAM OR EQUAL. SERVICE PRESSURE SHALL BE SUITABLE FOR SERVICE INTENDED. OH-O6-13 PROGRESS 2012 IPC Water Service Sizing Water Supply Drainage Supply 24. PROVIDE HANGERS AND SUPPORTS MEETING THE REQUIREMENTS SPECIFIED IN THE 2012 IPC SECTION 308. PLUMBERS TAPE AND WIRE ARE NOT ACCEPTABLE. Job Name: Ritz Carlton Conversion Fixture Units Fixture Units 08-08-13 PERMIT SET Job Number: 13068 Fixture Demand Total 25. CONTRACTOR SHALL AFFIX A MAINTENANCE LABEL TO ALL EQUIPMENT REQUIRING ROUTINE MAINTENANCE AND SHALL PROVIDE THREE COPIES OF MAINTENANCE AND OPERATING MANUALS GAS SHUT OFF VALVE Quantity Demand Total TO THE OWNER/OPERATOR. TYP. Engineer: Martin Zourek Fixture Units Fixture Units Fixture Fixture Individual Fixture Cold Hot Total Cold Hot Total Units Units 26. CONTRACTOR SHALL ARRANGE FOR AND PAY FOR ALL UTILITY METERS AND UTILITY CONNECTIONS. I Bathtub,private 4 2.0 2.0 1.4 8.00 8.00 5.60 2.0 8 Gothesw asher, residential 81b 1 1.0 1.0 1.4 1.00 1.00 1.40 2.0 2 27. ALL PLUMBING LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO THE GREATEST EXTENT POSSIBLE. ALL LINES NOT CONCEALED SHALL BE SECURED 6" OFF FLOOR AND u MECHANICAL Dishwasher,domestic 1 1.4 1.4 1.40 1.40 2.0 2 3/4" FROM WALL AND CEILINGS USING OFFSET BRACKETS. Drawn By: Checked By: LOW PRESSURE EQUIPMENT Ice Maker 1 0.5 0.5 0.50 0.50 28. AN APPROVED BACKFLOW PREVENTER SHALL BE PROPERLY INSTALLED UPSTREAM OF ANY POTENTIAL HAZARD BETWEEN THE POTABLE WATER SUPPLY AND A SOURCE OF CONTAMINATION. GAS LINE Kitchen Sink, private 1 1.0 1.0 1.4 1.00 1.00 1.40 2.0 2 MZ TOC Lavatory, private 5 0.5 0.5 0.7 2.50 2.50 3.50 1.0 5 29. ALL SINGLE AND THREE PHASE MOTORS, STARTERS AND DISCONNECTS SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR. 6" MIN. DRIP LEG Shower,private mixing valve 1 2.0 2.0 1.4 2.00 2.00 1.40 2.0 2 Water Goset, Flush Tank private 4 2.2 2.2 8.80 8.80 3.0 12 pLUMB ING Cold Hot Entry Drainage TYPICAL LOW PRESSURE WaterSupply/DrainFixtureUnitTotal 18 FixtureUnits 23.80 15.90 24.00 34.0 GAS CONNECTION DETAIL Flow-GPM 20 �$ 20.5 SPECS LEGEN Rpe Size 1-1/2" 1-1/4" 1-1/2" 4" � NO SCALE Velocity-FPS 3.20 4.30 3.40 S CHEDULES NOTE: IXISTING WH PROVIDES 500 GAL HOT WATER FIRST HOUR DR,4W AND 430 GAL CONTINUOUS DRAW WHICH IS SUFFICIENT TO SERV E ADDED FIXTURES. & DETAILS . 1 of 3 m COPYRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS,INC. 0 N � � SHEET DETAIL NOTES: GENERAL NOTES: °° � � � OCONNECT 3/4" HW& CW TO SH-1. G.C. TO PROVIDE FURR-OUT WALL IN 1. THIS PLAN INDICATES EXISTING PLUMBING INSTALLATION. VERIFY ALL � � N � � THIS LOCATION. ROUTE PIPING IN FURR-OUT WALL TO PREVENT PIPING ROUTING &SIZES IN FIELD PRIOR TO WORK. IF ANY SIZES AND � (� (� O � PIPING FREEZING IN WINTER TIME. ROUTING DIFFERS FROM SHOWN, CONTACT MECHANICAL ENGINEER FOR � � � U op FURTHER ASSISTANCE IF DESIRED. � •� pp O2 ALL PIPING IN THIS LOCATION SHALL BE ROUTED IN FURR-OUT WALL Reviewed for Code Compliance � � cn �� OR HEATING SPACE TO PREVENT FREEZING IN WINTER TIME. O �O a O Code: 2012 International Building Code (IBC) > O3 ROUTE PIPING DOWN IN A FURR-OUT WALL. HERE SHOWN OFFSET FOR r p'W� p� �,q�� By J Mon dragon a t 8:4 9 am, Sep 1 9, 2 0 1 3 V � 0- O� CLARITY. � �N N X O O4 LOCATE BALANCING VALVE IN THE CEILING OR WALL WITH ACCESS OR � � � � �V INSIDE THE KITCHEN UNDER THE COUNTER TOP.VERIFY EXACT .� � � (n '� MOUNTING LOCATION IN FIELD PRIOR TO INSTALLATION. BALANCE � � V O � FLOW AT 0.5 GPM. HERE SHOWN OFFSET FOR CLARITY. � � Q N � U O 5 RELOCATE EXISTING SHUT OFF VALVES AWAY FROM THE HALLWAY � � � � .� N � CD ap CCS INTO THE NEAREST WALL OR REMOVE THEM ENTIRELY. RELOCATE � t� � EXISTING LOW PRESSURE GAS REGULATOR TO CEILING AND PROVIDE O2 W � W � ~ � VENTING TO THE AMBIENT. VENT MIN. 3'ABOVE THE ROOF, 3'AWAY ��2�� � J = O � FROM ANY NATURAL OPENING INTO THE BUILDING, 10'AWAY FROM / � � ti � ANY MECHANICAL INTAKE INTO THE BUILDING AND 10' FROM WC-� c � w � � � PROPERTY LINE. VERIFY EXACT LOCATION OF GAS REGULATOR IN Og � W � FIELD. NOT SHOWN ON THIS PLAN FOR CLARITY. BACK FEED 1-1/4"G � � �HW� � � ��2�� }' U N O C LINE BELOW FEEDING EXISTING FIRE PLACE AND BB QS. CONTINUE XX" � � � / �� 3 ��� � � � � � G LINE ON THIS LEVEL TO THE NEW FP&KITCHEN RANGE. � O / �G }' � O � � � �—� \ � � � C � � O6 EXISTING PIPING ROUTED IN THE CEILING BELOW TO REMAIN. O / � \ U � Q op � L � O7 CONNECT 1/2"CW& HW TO LV-1. 1O�C 3�4„ / \ ��,cr�� � Q o '�V O8 CONNECT 1/2"CW TO WC-1. SH-1 CW 3/4° J�TE BBQ-� m N � 3/4" � 0 W 1/2" � �� 10 O9 CONNECT 3/4"CW& HW TO BT-1. 3�4�� ` ��� ��2„ O � 3/4" 10 EXISTING BBQ-1 TO REMAIN. VERIFY IN FIELD. �I C —� gT-� ��� rn��t���r,� � �.,L�,: ,�,t��� �fi��, rt,��.. 11 EXISTING FP-1 TO REMAIN. � �� gT_� � O / {;b`� '+r�'' `�l`'''.�. ;�, v� C7 h' , ��� ., 12 ROUTE 2" G TO RANGE, CONNECT 1/2"G TO IT. I BBQ-1 O Og / � / �112'-4 3/4" �� � �'� '� "* 13 ROUTE &CONNECT 1/2"G TO FP-2. �� _ _ � ���������W � � WC-1 — � � * � + _ / P; � 10'-6"X 12'-1" 3/4" �„ - � � � � �` 14 ROUTE &CONNECT 1/2"G TO DRYER. _ ��� / �° _ ; �C Y O15 CONNECT 3/4"CW& HW TO CWB-1. I 7 LV-1 — HW ��2�� / _� � __ �'*'�, �� ��. r �,�4�4 � (E) 1/2„ O — CW O16 EXISTING 1-1/2" MPG TO REMAIN. � �#�������� �y}��� (E) 1/2" � `�� O17 CONNECT 1/2"CW TO IM-1. � _ _ _ _ _ _ _ � _ _ _ _ _ _ � FP 2 (E) 1/2" HWC — p —G � G (E) 1-1/2" HW O BALCONY — — CW — — 5 O (E)2" CW 6 18 ROUTE &CONNECT 3/4" CW& HW TO KS-1. CONNECT 3/4" HW TO � — — HW HWC — - — I ' 1/2" 13 � � � (E)1-1/2" MPG 16 ADJACENT DW-1 PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. _ � �--I�H � I� Y 3/4" 4 3/4" � e� — — — — — — — — — — — � � 1/2" � � 1 _ _ , 1/2" e --- --- --- - �M IM-1 � I 2„ N I e � — — — — — — — — — — �� v ' 17 ' I � � - - � � � � O I RANGE 9 BT_� DRYER — n CWB-1 � I O 1-1/4" _ KITCHEN � ' 12 " � 14 '-D 15 z � � �" �� 0 z — — 1/2" I �� � � 15'-4"X 8'-0" � — � � O ; � 3/4° � �3/4" � � � � � 18 � N 3/4" 1/2" 3/4' � � O O t� v O 1/2" � Q KS-1 DW-1 G � � � — CW — I�� — - — HWHWC — — — Y—I J � � O8 � � � � �/ � ��� LL } WC-1 I �1�2„ �v-1 �., � O Z 1/2" �„ .� � WJ � � � 3/4., �� Q _ �/2" � � � O m � 1 1/4" � ♦ 1 GREAT ROOM ���2'-4 3/4° � � V 30'-6"X 15'-6" y � > � � � �11'' 2I � � , N - � BT-1 C , � � � C O � O 8 � . �a.s�WUW �. � I� �sa�v��aWr��s.. O - � � � W�_, U aRT � 1/2" � O 1/2" O — � 11 1/2�� � � � FP-1 LV-1 II� — — — —G— — — — — — — � I � T � — — — — — — — — — — — � ��► 4 - N � O I BBQ-1 11/4" T' 10 AEC PROJECT #: 13068.00 DATE: ISSUE: 08-06-13 PROGRESS UP 08-08-13 PERMIT SET Drawn By: Checked By: MZ TOC 2ND FLOOR DHW & GAS NORTH PLAN 2ND FLOOR DHW & GAS PLAN SCALE 1/4" = 1'-0" SCALE: 1/4"= 1'0" • 2 of 3 m COPYRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS,INC. 0 N � � � SHEET DETAIL NOTES: GENERAL NOTES: � � � � N � � 1O EXISTING 4"W IN A SHAFT TO REMAIN. 1. THIS PLAN INDICATES EXISTING PLUMBING INSTALLATION. VERIFY ALL � V � O � PIPING ROUTING &SIZES IN FIELD PRIOR TO WORK. IF ANY SIZES AND — � O pp O2 EXISTING 2"W& 1-1/2"V IN THIS AREA TO BE REMOVED OR CAPPED ROUTING DIFFERS FROM SHOWN, CONTACT MECHANICAL ENGINEER FOR = R@VI@W@CI 'FOP COd@ COfY1p11111C@ � � '� U pp AND ABANDONED. FURTHER ASSISTANCE IF DESIRED. � (n � � � Code: 2012 International Building Code (IBC) � � o ti O3 EXISTING 1-1/2"W TO BE REMOVED OR CAPPED AND ABANDONED. 2. ALL THIN DASHED LINES INDICATE EXISTING PLUMBING. ALL EXISTING r��� �� UA�L ' gy J Mondragon at 8:49 am, Sep 19, 2013 O �O a O WA STE PIPING RO UTED UNDER THE FLOOR DECK (IN THE CEILING � U �, �- � O4 REPLACE EXISTING 1-1/2"W IN THIS AREA WITH NEW 3"W. BELOW) UNLESS OTHERWISE NOTED. ALL DASHED THICK WASTE LINES � � d" � INDICATE WASTE LINES ROUTED UNDER THE FLOOR DECK(IN THE � �� N X O O5 EXISTING 3"W TO BE REMOVED OR CAPPED AND ABANDONED. CEILING BELOW). � � � � � V .� � � � _ O6 CONNECT 3"W&2"V TO WC-1. 3. P.C. TO PROVIDE CLEANOUTS AT EACH CHANGE OF DIRECTION OF THE N .� HORIZONTAL WASTE LINES GREATER THAN 45°WITHIN 40 FT OF N � V � N � O7 REPLACE EXISTING 1-1/2"W WITH A NEW 2"W. DEVELOPED LENGTH OF THE DRAINAGE PIPING. VERIFY EXACT LOCATION � � a � � � OF CLEANOUTS IN FIELD. �� � � � � � O8 REPLACE EXISTING 2"W WITH A NEW 3"W IN THIS AREA. EXTEND AS � V � INDICATED. 14 w � W � � �ti � 9 DEMO WCO IN THIS LOCATION. 2��V � I` UJ = O O (E)2 V (� W � (n � � WC-1 � LV-1 �3 1-1/2"W L � 10 CONNECT 2"W& 1-1/2"V TO SH-1 & BT-1. � � ° � O � LV-1 13 �' U N O � 11 CONNECT 2"W& 1-1/2"V TO CWB-1. CONNECT 2'W FROM CWB-1 TO �E� 3 W 15 `'�-. V �C .V � O THE NEAREST 3"W OR LARGER. � � � � � � "� 5 �- � � � N 12 CONNECT 2"W& 1-1/2"V TO KS-1. CONNECT WASTE FROM DW-1 INTO 3 W�O e � � � � � N O THE KITCHEN WASTE LINE VIA AIR GAP OR VACUUM BREAKER. 2 W � � � Q � � � � �E�3„W \ � 13 CONNECT 1-1/2"W&V TO LV-1. \ / (E) 1 1/2"V (E) 1-1/2"W O3 Q O � / �E�2„V m 14 REPLACE EXISTING 1-1/2"V WITH 2"V. �� 1 1/2"V �8 > � � 0 SH-1 � O15 CONNECT 1-1/2"V TO THE EXISTWG 2"V LINE. 10 1-1/2"V� � „ 6" X 18'-0" O �� (E)4 W ; zrarcu 16 EXISTING 3"V.U.T.R. VERIFY EXACT LOCATION IN FIELD. I N BT-1 NA BT-1 2"W � �'� � O 7 e �E)2��V DECK }b������� �fi�`''��5,�`,';°,„_ BALCONY 1-1/2"V �\ 10 O / � v� Y � � � N' ��� � �� — � � � �, .,��� ��J��. 2"W� 3��W � / �112'-4 3/4° �U � � ,- �. / (E) 3"V.U.T.R. � _ - ` . � . WC-1 � r7� 10'-6"X 12'-1' 3��W O 2��V 16 �.,� � �7 � ;�; 1-1/2��W �2,�V / y�r� r� ti (E) 1-1/2"V �¢�" ��SI ��' +�'�4� � � �C �E�2��W ���,� O�AL� �y,�� LV-1 2O `�� , �3 � 2„V �112' -4 3/4" I � - -V 2"V 111'-3 3/4" O y 3"W � \ BALCONY � _ i (E)4"W �,, �� — — — — — — — — — — � 1-1/2"V � e � - - - - - � 2„W 3��W 3��W vM � 11 111'-4 3/4" w I O I y COWB-1 `Y 1-1/2"V 2��V Y3 � � KITCHEN I � I 1-1/2°v � 15'-4"X 8'-0„ 10 BT-1 �� 2"W � O 2„V � O � 2 V O I O 1-1/2"V �.� I � UNDER � � (E)4"W � Q i 2,�V SLAB � �L - - - - - - - � I — — – W — — — — — � 1 KS-1 DW-1 e e 2��V B � e O J � � �2 WC-1 � � O � �E�4.�W �E�4,�W � 2„W O 3„W I � � O � g LV-1 � V W J O 13 � � '� J p� 3nW� p � � O m � � �1 � 2°v � l p U GREAT ROOM 112'-4 3/4° � U � 30'-6"X 15'-6" Y � � Q I �I � � 111'-4 3/4" �• z -� � � ��� N Q � � 10 BT-1 p� O � 2"W � BEDROOM 2 � 6 � � 3..W o v ART 13'-0"X 11'-10" 12'-3" X 12'-6" WC-1 � NICHE � ENTRY � 1-1/2"W � {n ° N� 13 L -1 AEC PROJECT #: 13068.00 DATE: ISSUE: 08-06-13 PROGRESS UP 08-08-13 PERMIT SET Drawn By: Checked By: MZ TOC 2ND FLOOR S ANITARY NORTH WASTE 2ND FLOOR SANITARY WASTE & VENT PLAN & VENT PLAN SCALE 1/4" = 1'-0" SCALE: 1/4"= 1'0" • 3 of 3 m COPYRIGHT 2013 ARCHITECTURAL ENGINEERING CONSULTANTS,INC.