Loading...
HomeMy WebLinkAboutB13-0441 specifications.pdf B13-0441 ACTIVE ENERGIES SOLAR.. Solar Installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-423 3/info @activeenergies.com) Site: Friedman Residence 1150 B Sandstone Drive Unit B Vail, CO 81657 All AC wiring to be completed by a Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F Panel Arrangement:flush mounted ---- IN r�I W 000 000 •f , Ri g W ' if Pf, LL :. FV:+.W N t I❑I _ 2 s I I II II I _ 1 I <o29 ¢O ---------- II I II I J NJ� riLMll�fa•'M d 9dA I II - I II I II ~ — I II I II I I � I II III II �fiF` rl, I I—� I II I III II I I I f I II I III II I I I I II I III II I `.. II I I I II I III II I II „ I I II I III II ,- I I I+ II III II I J �� R�dGF KLAN � •� RECEIVED Page 1 of 4 BY David Rhoades at 1:20 pm, Oct 04, 2013 10/4/2013 P.O.Box 7627,Avon,CO 81620 1 P: 970.227.0272 1303.330.4880 1 F: 866.403.3485 1 www.wtiveenergies.com ACTIVE ENERGIES SOLAR.. Calculations 3.5kW System Size (STC) 14 Phono Solar PS250P-20/U solar panels @ 250 watts 14 Enphase M-215 240 micro-inverters—1 branch of 14 units each Fixed array tilt angle: 26.520 Array azimuth: 125° (where 180°is south) Estimated annual power production: 4,784kWh Maximum PV System Voltage: 690.7 Voc= 37.8V/module 37.8V x 1 module= 37.8V Temperature correction factor 690.7(A) STC =25°C, Temperature Coefficient (Voc) = -0.31%/°K (298°K- 233°k) = 65°K 37.8V+ (-65°K x (-0.31%/°K x 37.8V) x 1 module) =45AV Temperature correction factor Table 690.7 For-40°F use 1.25 37.8V x 1.25 =47.3V Maximum PV Source Circuit(String) Current: 690.8 (A)(1) IS, = 8.7A 8.7A x 1.25 = 10.9A Maximum PV Output Circuit (Array) Current: 690.8 (A)(2) 10.9A x 1 strings = 10.9A Inverter Output Circuit Current: 690.8 (A)(3) .9A @ 240V John Wiles, "Photovoltaic Power Systems and the National Electrical Code: Suggested Practices", 2005, pp. E1-E25. Page 2 of 4 10/4/2013 P.O.Box 7627,Avon,CO 81620 1 P_ 970.227.02721303.330.4880 1 F: 866.403.3485 1 www.activeenergies.corn ACTIVE ENERGIES SOLAR.. Conductor Sizing Pass Thru Box on Roof to Disconnect to Service Panel(for a 14 panel circuit): Nameplate maximum continuous output current: .9A Maximum Output Power 215 Watts AC 215W-240 V= .9A .9A x 14 inverters = 12.6A per branch 12.6A x 125%= 15.8A #10 THWN-2 or NM-13 Table 310.16 40A (90°C column, see note 240.4(D)) Conduit fill adjustment Table 310.15 (B)(2)(a) No Conduit Fill Adjustment Temperature correction factor Table 310.16 No Temperature Correction Overcurrent Protection Device per circuit 20A two pole breaker Per Manufacturer Specification Page 3 of 4 10/4/2013 P.O.Box 7627,Avon,CO 81620 1 P_ 970.227.02721303.330.4880 1 F: 866.403.3485 1 www.activeenergies.corn M VL � W N O N V N c*¢> L[7 6fj t d C d mO u w L O ( d 0_ N OM o0 N LO _O O y 0 C C e v ° c Ll II cc 41) E moo ^ a) a, o o� m }6 c��l Ym a v oO m EQ - -41) 2E a) inc^ioo m > � m Y° o � c ^ aa'i o T °irn v o � � mY T O II II Q.0 C U > U �. a) J O t0 ? U O W U W CC yW c 0 C m � N . WA a3 + o OZ � U d Q ,O r N O_ d > r .p C .a3 N j _ i U to 0 'O c0 C Z a) O a) a7 O E r m /) m o m e m Q r U) a � v T U Q O.X O Q _0 \ ? c .y Q m Q L Lf) Q ° C 0 Vi X00 as Co a m �_2 — � � cdTo a � a -a Fu C13 Lo 0 O O (n N Q S C a) C 2 N Z V! O a) 0_ 0_ (O In 0_.0 U .y Q U cU� cC a o _0 N O U N 15 E Z c c c c c c U O a Z 01" p -O T O N N Q .0.. U 00 V ti W E V O O pc M 8 d N m y O N a: cccccc O U C f0 c0 Q °OU a Tl� : U C", N N y a T C d Z li m c� > 02 H J d W H _ lJJ C) 00 Cl)O XO m p m M o � M j C rn O] � M N a) 2c 1 t` co U 0 N L a)c > ^ O N �a) m � � N CO U °° N Ir o 0 x Q = z = "oC3 E a) � > cr t�F O l� JL°n C r � 00 O U 0 m d 3 w w =z c c J 4 U o o O ..' N > CG a y -m o o a L r Q` T d o_ m .V+ N0 � d C C C O U C Q K V m N W D C 0 0 Z O O N t N c-) V m � � E 4-.I xO 4 p m W O O � bA C� r ABOUT PHONO SOLAR Phono Solar Technology Co., Ltd. is one of the world's leading renewable energy product manufacturers and a well trusted brand provider. The Phono Solar brand has become synonymous with high performing, top quality photovoltaic panels that are ideal for use in large scale power plants,, , +. commercial and residential installations. a r - • HIGH PERFORMANCE SOLAR ■ ■ ■ ■ MODULES RELIABLY HIGH YIELDS QUALITY ASSURANCE WARRANTIES • High efficiency solar cells together • Durability assured in even the • 10-year product warranty* with high transmission textured glass harshest environments with AMMONIA • 25-year performance warranty* deliver module efficiency of over 16.0%, CORROSION, SALT MIST CORROSION, • Free module recycling through PV leading to minimized installation costs and FIRE TEST certifications. Cycle Association membership** and maximized system output. e Certified to withstand increased snow • High output due to excellent and wind loads of up to 5400Pa. performance in weak-light conditions. • Manufacturing facility certified by ISO • Higher specific yields due to positive 9001, ISO 14001 and OHSAS 18001. power sorting. • Internal quality control with standards • Product quality is assured through the higher than both IEC and UL. use of branded components. C us CEC M _ PV CYCLE yte C S Clean Energy Council NKJF * IN COMPLIANCE WITH OUR WARRANTY TERMS AND CONDITIONS. IN PV CYCLE MEMBER COUNTRIES ONLY,SEE: WWW.PVCYCLE.COM ONYX . Phono Solar MECHANICAL CHARACTERISTICS ABSOLUTE MAXIMUM RATING Polycrystalline 156mm x 156mm square, 6 x 10 pieces in series Parameter Values Length: 1640mm(64.6 inch) Operating Temperature From -40 to+85°C Width: 992mm(39.1 inch) Typical Application 20V DC Height:45mm (1.8 inch) Hail Diameter @ 80km/h Up to 25mm 20kg(44.1lbs) Surface Maximum Load Capacity Up to 5400Pa 3.2mm toughened glass Maximum Series Fuse Rating 15A Anodized aluminium alloy IEC Application Class(IEC 61215) A 0.90m wire(o4mmz) Fire Rating(UL 1703) C 6 pieces Schottky by-pass diodes 1000V DC(IEC 61215) Maximum System Voltage IP 65 rated 1000V DC(UL 1703) ELECTRICAL TYPICAL VALUESI,2 Model Rated Power(Pmpp) Tolerance Rated Current(Impp) Rated Voltage(V,p) Short Circuit Current 00 1 Open Circuit Voltage(V.,) I Module Efficiency N) PS235P-20/U 235W 0-+5W 7.94A 29.6V 8.40A 373V 14.44 PS240P-20/U 240W 0-+5W 8.06A 29.8V 8.50A 37.5V 14.75 PS245P-20/U 245W 0-+5W 8.184 30.OV 8.60A 37.7V 15.06 PS250P-20/U 250W 0-+5W 8.30A 30.2V 8.70A 37.8V 15.37 PS255P-20/U 255W 0-+5W 8.42A 30.4V 8.80A 37.9V 15.67 PS260P-20/U 260W 0-+5W 8.53A 30.6V 8.90A 38.OV 15.98 PS265P-20/U 265W 0-+5W 8.61A 30.8V 9.00A 38.1V 16.29 DIMENSIONS TEMPERATURE CHARACTERISTICS • •. 2 C 45°C± ° 860(33.86) 1360(53.541 .......... Voltage Temperature Coefficient /K Current Temperature Coefficient 0 0 0 0.40%/K Section A-A WEAK LIGHT PERFORMANCE g u 900135.431 1110.43) 1000 1 1 800 0.8 0.996 45(1.771 600 0.6 0.99 frame(block) 400 0.4 0.983 200 0.2 0.952 100 0.1 0.921 35(1.38) PACKING CONFIGURATION 40'HQ Pieces per pallet 22 Pallets per container 28 1640(64.57) Note:mm(inch) 616 PARTNER INFORMATION Note: This datasheet summarises product warranty and specifications, which are subject to change without notice. The exact module specification will be subject to the description in the sales contract. Further information can be found on our website: www.phonosolar.com 1.Defined as standard deviation of thousands measurements.Absolute power values depend on the measuring system.They can differ by+/-5%from one measuring system to another. 2. Measurement conditions under irradiance level of Standard Test Condi lons(STC): 1000W/m', Air mass 1.5 Spectrum,cell temperature of 25°C. www.phonoso[ar.com EN-U-P-BB-1210 re] ENPHASE MICROINVERTER M215 .� [e] enphae E N E R G Y The Enphase Energy Microinverter System improves energy harvest, increases reliability, and dramatically simplifies design, installation and management of solar power systems. The Enphase System includes the le U fd I I I IIU UII IVCI LUI, tI r--.Iy CUII IIII I IIUI IL c1LIUI lJ VcUWy, al IU EI IIJy l ILUI 1I, Enphase's monitoring and analysis software. - Maximum energy production P R o D u c T I v E - Resilient to dust, debris and shading - Performance monitoring per module - System availability greater than 99.8% R E i A a E - No single point of system failure SMART - Quick & simple design, installation and management - 24/7 monitoring and analysis S A F E - Low voltage DC - Reduced fire risk cl �s c MICROINVERTER TECHNICAL DATA Input Data (DQ M215-60-2LL-S22623 M215-60-2LL-S22-NA/S23-NA(Ontario) Recommended maximum input power(STC) 260W Maximum input DC voltage 45V Peak power tracking range 22V—36V Operating range 16V—36V Min./Max.start voltage 26.4W45V Max. DC short circuit current 15A Max. input current 10.5A Output Data (AQ @208 Vac @240 Vac Maximum output power 215W 215W Nominal output current 1.0 A* 0.9 A* Nominal voltage/range 208W1 83V-229V 240W21 1 V-264V Extended voltage/range 208W1 79V-232V 240W206V-269V Nominal frequency/range 60.0/59.3-60.5 60.0/59.3-60.5 Extended frequency/range 60.0/59.2-60.6 60.0/59.2-60.6 Power factor >0.95 >0.95 Maximum units per 20A branch circuit 25(three phase) 17(single phase) Maximum output fault current 1.05 Arms,over 3 cycles;25.2 Apeak, 1.74ms duration *Arms at nominal voltage Efficiency CEC weighted efficiency 96.0% Peak inverter efficiency 96.3% Static MPPT efficiency(weighted, reference EN 50530) 99.6% Dynamic MPPT efficiency(fast irradiation changes, reference EN 50530) 99.3% Night time power consumption 46mW Mechanical Data Ambient temperature range -40°C to+65°C Operating temperature range(internal) -40°C to+85°C Dimensions(WxHxD) 17.3 cm x 16.4 cm x 2.5 cm(6.8" x 6.45"x 1.0")* Weight 1.6 kg (3.5 Ibs) Cooling Natural convection—no fans Enclosure environmental rating Outdoor—NEMA 6 without mounting bracket Features Compatibility Pairs with most 60-cell PV modules Communication Power line Warranty 25-year limited warranty Compliance UL1741/IEEE1547, FCC Part 15 Class B CAN/CSA-C22.2 NO.0-M91,0.4-04,and 107.1-01 Enphase Energy, Inc. 06/13/2011 201 1St Street, Petaluma, CA 94952 877 797 4743 www.enphase.com ®Printed on 100 percent recycled paper. aer�ruacutn OOtl210100`IItlA NOI SIA108fIS 2Jtllosvo oz�w q vow zsca x��v oa NJIS30'8 11 Nf11Stl3'3AI2J03NO1SONtlS OSIb Ll un10311HOUV 303nuN 3 NOUVAON3N NVWa31b3 IRAN M $ E �o a®, 'ono r--- ---�1 III e I o 1 •_ "� �-== �m— � g � 1,­-t, E I I O II Irr- III III _ 0 � II II II dl III al-AI 0 ,I ---------------J� I I I II II I, II Z 0 II II II LL.' II II II O m �I II II O II II II II II d II II ,I I� II II II II II II Z I II h 7— Q ----� -- --------- L ----------------s7 - -lr----ter-- -7 FT7 ----------------� = W 0 J I 0 W= IL---_ 11 r -I F---- 0 SOLARMOUNT Technical . . . - - ::� UNIRAC A Ifl UP GROUP COMPANY SolarMount Technical Datasheet Pub 110818-ltd V1.0 August 2011 SolarMount Module Connection Hardware.................................................................. 1 BottomUp Module Clip.................................................................................................1 MidClamp ....................................................................................................................2 EndClamp....................................................................................................................2 SolarMount Beam Connection Hardware......................................................................3 L-Foot...........................................................................................................................3 SolarMountBeams..........................................................................................................4 SolarMount Module Connection Hardware SolarMount Bottom Up Module Clip Part No. 302000C Washer Bottom Up Clip material: One of the following extruded aluminum Bottom Nut (hidden..see alloys: 6005-T5, 6105-T5, 6061-T6 t. Up Clip note*) Ultimate tensile: 38ksi,Yield: 35 ksi Finish: Clear Anodized • Bottom Up Clip weight: -0.031 Ibs (14g) Beam • Bolt Allowable and design loads are valid when components are ' assembled with SolarMount series beams according to authorized UNIRAC documents • Assemble with one'/4"-20ASTM F593 bolt, one '/"-20ASTM F594 serrated flange nut, and one 1/4"flat washer • Use anti-seize and tighten to 10 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- _ party test results from an IAS accredited laboratory Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Load Factor, Ibs(N) Ibs (N) FS Ibs(N) CD t Tension,Y+ 1566(6967) 686(3052) 2.28 1038(4615) 0.662 Y Transverse,X± 1128(5019) 329(1463) 3.43 497(2213) 0.441 F F.44 ip-X Sliding, Z± 66(292) 1 27(119) 2.44 41 (181) 0.619 Dimensions specified in inches unless noted a 0 ::OUNIRAC . - , . , , - - A I II Ln GROUP COMPANY SolarMount Mid Clamp Part No.302101 C,302101 D,302103C,302104D, 302105D,302106D ' Mid clamp material: One of the following extruded aluminum Midt rra t ° Bolt alloys: 6005-T5, 6105-T5, 6061-T6 Fla e Nu Ultimate tensile: 38ksi,Yield: 35 ksi Clamp . -'�_ • Finish: Clear or Dark Anodized _ Mid clamp weight: 0.050 Ibs (23g) Allowable and design loads are valid when components are mot``-ems assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac'/4"-20 T-bolt and one '/"-20 ASTM F594 serrated flange nut ., Use anti-seize and tighten to 10 ft-Ibs of torque Beam Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- party test results from an IAS accredited laboratory Applied Load Average Allowable Safety Design Resistance 3.Wj aES'T,vc€ - Direction Ultimate Load Factor, Load Factor, Ibs(N) Ibs(N) FS Ibs(N) Tension,Y+ 2020(8987) 891 (3963) 2.27 1348(5994) 0.667 Transverse,Z± 520 (2313) 229(1017) 2.27 346(1539) 0.665 Y Sliding, X± 1194(5312) 490(2179) 2.44 741 (3295) 0.620 ll�X Dimensions specified in inches unless noted SolarMount End Clamp Part No.302001C,302002C,302002D,302003C, 302003D,302004C,302004D,302005C,302005D, 302006C,302006D,302007D,302008C,302008D, 302009C,302009D,302010C,302011C,302012C End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 Bolt Ultimate tensile: 38ksi,Yield: 35 ksi • Finish: Clear or Dark Anodized • End clamp weight: varies based on height: 0.058 Ibs (26g) Erid Clamp Allowable and design loads are valid when components are Serrated assembled according to authorized UNIRAC documents Flange Nut Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated �w Assemble with one Unirac'/"-20 T-bolt and one '/"-20 ASTM F594 . serrated flange nut B Use anti-seize and tighten to 10 ft-Ibs of torque Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- Y party test results from an IAS accredited laboratory * Modules must be installed at least 1.5 in from either end of a beam wx .s Applied Load Average Allowable Safety Design Resistance " '"-"- ~ Direction Ultimate Load Factor, Loads Factor, Ibs(N) Ibs(N) FS Ibs(N) 4) ,r�es Tension,Y+ 1321 (5876) 529(2352) 2.50 800 (3557) 0.605 Transverse, Z± 63(279) 14(61) 4.58 21 (92) 0.330 Sliding,X± 142 (630) 52(231) 2.72 79(349) 1 0.555 Dimensions specified in inches unless noted 0 . Technical . , , - - ::� UNIRAC A III LTI GROUP COMPANY SolarMount Beam Connection Hardware SolarMount L-Foot Part No. 304000C, 304000D _ L-Foot material: One of the following extruded aluminum alloys: 6005- _ T5, 6105-T5,6061-T6 F _x Ultimate tensile: 38ksi,Yield: 35 ksi • Finish: Clear or Dark Anodized .� L-Foot weight: varies based on height: —0.215 Ibs(98g) • Allowable and design loads are valid when components are Bea assembled with SolarMount series beams according to authorized Bolt UNIRAC documents L-Foot For the beam to L-Foot connection: •Assemble with one ASTM F593 W-16 hex head screw and one errated ASTM F594 W serrated flange nut Flange Nu • Use anti-seize and tighten to 30 ft-Ibs of torque Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third-party test Y results from an IAS accredited laboratory * NOTE: Loads are given for the L-Foot to beam connection only; be X sure to check load limits for standoff, lag screw, or other y attachment method 3,,4, Applied Load Average Safety Design Resistance MROTFOU. Direction Ultimate Allowable Load Factor, Load Factor, Ibs(N) Ibs(N) FS Ibs(N) 4) y 2 u Sliding,Z± 1766(7856) 755(3356) 2.34 1141 (5077) 0.646 Tension,Y+ 1859(8269) 707(3144) 2.63 1069(4755) 0.575 Dimensions specified in inches unless noted Compression,Y- 3258(14492) 1325(5893) 2.46 2004(8913) 0.615 Traverse,X± 1 486(2162) 213(949) 2.28 323(1436) 0.664 a 0 SOLARMOuNT Technical Datasheets � UNIRAC A I II Ln GROUP COMPANY SolarMount Beams Part No. 310132C, 310132C-B, 310168C, 310168C-B, 310168D 310208C, 310208C-B, 310240C, 310240C-B, 310240D, 410144M, 410168M, 410204M, 410240M Properties Units SolarMount SolarMount HD Beam Height I in I 2.5 I 3.0 Approximate Weight(per linear ft) plf 0.811 1.271 Total Cross Sectional Area in 0.676 1.059 Section Modulus(X-Axis) in 0.353 0.898 Section Modulus(Y-Axis) in 0.113 0.221 Moment of Inertia (X-Axis) in 0.464 1.450 Moment of Inertia(Y-Axis) in 0.044 0.267 Radius of Gyration (X-Axis) in 0.289 1.170 Radius of Gyration (Y-Axis) in 0.254 0.502 SLOT FOR T-BOLT OR 1.728 SLOT FOR T-BOLT OR 14" HEX HEAD SCREW 1/"HEX HEAD SCREW 1E 1 2X SLOT FOR SLOT FOR BOTTOM CLIP 2.500 BOTTOM CLIP T 3.000 1.316 SLOT FOR Lr—io Ll HEX BOLT SLOT FOR 1.385 3/s" HEX BOLT .387 .750 1.207 Y Y 1.875 A A lw X t X SolarMount Beam SolarMount HD Beam Dimensions specified in inches unless noted a " L" Feet T' Feet are fabricated from high strength 3/16" aluminum and Jhk include a vertical slot for adjusting to irregular surfaces. Weight "L"Style Foot !� w/Turn Bolt Description Part# 1-49 7.00 LF2 2.5"Tall 50-99 0.20 6.50 ~� L-Mounting Foot 100+ 6.00 1-49 9.00 LF3 3.5"Tall 50-99 0.24 8.50 ,0r� L-Mounting Foot `� 100+ 7.00 1-49 10.00 Power Post Bracket LF5 5"Tall 50-99 0.40 9.25 4-2. w/rurn Bolt L-Mounting Foot 100+ 8.50 1-49 12.00 LF6 6"Tall 50-99 0.45 11.00 L-Mounting Foot 100+ 9.75 1-49 6.50 PPB Power Post 50-99 .09 6.00 Bracket 100+ 5.50 Easy Feet TM Easy Feet mount directly to metal and composite shingles or other roofing materials and do not require attachment to a roof structural member.Sealing butyl mastic backing and RSS PHEinoxT"screws are included. Weight Per Part# Description Quantity Unit(Ibs.) Price Pivot Easy 1-49 21.50 # PEF-1.5 Mounting Foot 50-99 0.76 20.50 w/1.5" Screws 100+ 19.00 Pivot Easy 1-49 22.00 ` PEF-2.0 Mounting Foot 50-99 0.78 21.00 w/2.0" Screws 100+ 19.50 Pivot Easy 1-49 23.00 PEF-3.0 Mounting Foot 50-99 0.82 22.00 w/3.0" Screws 100+ 20.50 RSS PHEinoxT^"screws are manufactured by GRK Fasteners. (800) 260.3792 www.DPWSolar.com 8 ff- ,A.POWER-FAB'