Loading...
HomeMy WebLinkAboutF13-0037 stamped approved plansHydraulic Overview Job Number: CS2078 Report Description: Residential Node Flow(gpm)Hose Flow(gpm)Static(psi)Residual(psi)Name 4 724.00 100.00 150.000 77.314Water Supply Identifier Pressure(psi)K-Factor(K)Flow(gpm) Job System Supplies Check Point Gauges CS2078 Jason Brochu Villa Cortina 130 22 W Meadow Dr Vail, CO 81657 CS2078-FP1-VillaCortina130.cad Job Name: Address 1 Address 2 Design Engineer Phone FAX State Certification/License Number AHJ Job Site/Building Most Demanding Sprinkler Data Coverage Per Sprinkler System Pressure Demand Total Demand Area of Application Hose Streams Number Of Sprinklers Calculated System Flow Demand Pressure Result Job Number 195.10 @ 126.241 Water Supply at Node 4 (724.00, 100.00, 150.000, 77.314) 0.100gpm/ft² 5.8 K-Factor 19.60 at 11.420 100ft² 126.241 900ft² (Actual 247ft²) 100.00 4 95.10 Density +17.333 (12.1%) Address 3 © M.E.P.CAD, Inc.10/4/2013 Page 1AutoSPRINK® VR10 v10.0.55.0 11:41:38AM Hydraulic Graph Report Description: Residential Job Number: CS2078 System Demand (Including Hose Allowance at Source) System Demand 77.314 @ 724.00 Residual: Pressure 150.000 Static: Pressure Water Supply at Node 4 Hydraulic Graph Water Supply at Node 4 126.241 @ 95.10 126.241 @ 195.10 Available Pressure at Time of Test 143.574 @ 195.10 © M.E.P.CAD, Inc.10/4/2013 Page 2AutoSPRINK® VR10 v10.0.55.0 11:41:46AM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Residential Job Number: CS2078 Sprinkler 104 25.92 19.60 5.8 19.965 Sprinkler 106 25.51 19.60 5.8 19.352 Sprinkler 108 24.07 19.60 5.8 17.224 Sprinkler 109 19.60 19.60 5.8 11.420 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.10/4/2013 Page 3AutoSPRINK® VR10 v10.0.55.0 11:41:53AM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CS2078 Report Description: Residential • • • • • Route 1 • • • • • Pf Pe Pv BL 1.10 19.60 6.60 0.065545 150'-0"11.077 109 8'-6"19.60 5.8 11.420 19'-0" 30 8'-6"22.497 169'-0" 150 Sprinkler 2E(7'-0"), T(5'-0") Pf Pe Pv BL 1.60 43.67 6.99 0.047024 50'-0"2.727 30 8'-6"24.07 22.497 8'-0" 28 8'-6"25.224 58'-0" 150 Flow (q) from Route 2 T(8'-0") Pf Pe Pv BL 1.60 69.19 11.07 0.110150 50'-0"6.389 28 8'-6"25.51 25.224 8'-0" 29 8'-6"31.613 58'-0" 150 Flow (q) from Route 3 T(8'-0") Pf Pe Pv BL 1.60 95.10 15.21 0.198426 300'-0"68.060 29 8'-6"31.613 43'-0" 18 8'-6"99.673 343'-0" 150 3T(8'-0"), 2E(9'-0"), cplg(1'-0") Pf Pe Pv FM 2.00 95.10 9.68 0.066044 50'-0"4.029 18 8'-6"99.673 11'-0" 16 8'-6"103.702 61'-0" 150 E(11'-0") Pf Pe Pv FM 2.47 95.10 6.37 0.036035 113'-10"4.786 16 8'-6"103.702 19'-0"5.993 12 -5'-3½"114.481 132'-10" 120 BV(7'-0"), 2E(6'-0") Pf Pe Pv FM 4.03 95.10 2.40 0.003331 3'-9"0.032 12 -5'-3½"114.481 6'-0"1.627 13 -9'-0½"116.141 9'-9" 120 LtE(6'-0") Pf Pe Pv FM 4.26 95.10 2.14 0.002530 11'-3"14.367 13 -9'-0½"116.141 23'-8½"0.867 3 -11'-0½"131.375 34'-11½" 120 BFP(-10.278), PRV(-4.000), BV(15'-9½"), LtE(7'-11") Pf Pe Pv UG 4.22 95.10 2.18 0.001991 3'-7"0.040 3 -11'-0½"131.375 16'-8½"1.556 2 -14'-8"132.971 20'-4" 140 E(16'-8½") Pf Pe Pv UG 4.26 95.10 2.14 0.002530 240'-0"0.640 2 -14'-8"132.971 13'-2"-7.370 4 2'-4"126.241 253'-2" 120 E(13'-2"), S 195.10 100.00 Hose Allowance At Source 4 • • • • • Route 2 • • • • • Pf Pe Pv BL 1.10 24.07 8.11 0.095861 50'-0"5.272 108 8'-6"24.07 5.8 17.224 5'-0" 30 8'-6"22.497 55'-0" 150 Sprinkler T(5'-0") • • • • • Route 3 • • • • • Pf Pe Pv BL 1.10 25.51 8.60 0.106765 50'-0"5.872 106 8'-6"25.51 5.8 19.352 5'-0" 28 8'-6"25.224 55'-0" 150 Sprinkler T(5'-0") • • • • • Route 4 • • • • • Pf Pe Pv BL 1.10 25.92 8.73 0.109888 100'-0"11.648 104 8'-6"25.92 5.8 19.965 6'-0" 29 8'-6"31.613 106'-0" 150 Sprinkler cplg(1'-0"), T(5'-0") 1.51 4.87 )(150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.10/4/2013 Page 4AutoSPRINK® VR10 v10.0.55.0 11:42:00AM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CS2078 Report Description: Residential Pipe Type Legend AO Arm-Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Units Legend Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen-Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc.10/4/2013 Page 5AutoSPRINK® VR10 v10.0.55.0 11:42:00AM The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bu l l e t i n 1 7 6 Re v . B Bulletin 176 Rev. B Model F1 Residential Sprinklers for Design Density of .10 gpm/ft2 Model F1 Res Sprinklers Listed to meet the minimum design density as required by UL1626. Types: 1. F1 Res 30 Pendent 2. F1 Res 30 Recessed/F2 3. F1 Res 30 Recessed/FP 4. F1 Res 30 CCP Pendent 5. F1 Res 49 Pendent 6. F1 Res 49 Recessed Pendent/F1 7. F1 Res 49 Recessed Pendent/FP 8. F1 Res 49 CCP Pendent 9. F1 Res 58 Pendent 10. F1 Res 58 Recessed Pendent/F1 11. F1 Res 58 Recessed Pendent/FP 12. F1 Res 58 CCP Pendent 13. F1 Res 44 & 58 HSW 14. F1 Res 44 & 58 HSW Recessed HSW/F2 15. F1 Res 58 HSWX 16. KRes58 HSWX 17. F1 Res 44 SWC 18. F1 Res 76 Pendent 19. F1 Res 76 Recessed Pendent/F1 20. F1 Res 76 Recessed Pendent/FP 21. F1 Res 76 CCP Pendent F1 Res 30, 49, 58 & 76 Recessed Pendent/F1 The 3mm glass-bulb pendent sprinklers permit the ef- ficient use of residential water supplies for sprinkler cover- age in residential fire protection design. Upon fire conditions, rising heat causes a sprinkler’s heat-sensitive glass-bulb to shatter, releasing the water- way for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: • Thermal Sensor: Nominal 3mm glass-bulb • Sprinkler Frame : Brass Casting • Sprinklers’ Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: ½” NPT (R1/2) • K-Factor: 3.0 (Actual) - F1 Res 30 Pendent Sprinkler 4.9 (Actual) - F1 Res 49 Pendent Sprinkler 5.8 (Actual) - F1 Res 58 Pendent & HSW/HSWX Sprinkler 7.6 (Actual) - F1 Res 76 Pendent Sprinkler 4.4 (Actual) - F1 Res 44 HSW Sprinkler • Density: Minimum 0.10 gpm/ft2 F1 Res 30, 49, 58 & 76 Recessed Pendent/FP F1 Res 30, 49, 58 & 76 CCP Pendent F1 Res 44 & 58 Recessed HSW/F2Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 2. NYC MEA 258-93-E UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 & 58 Pendent Sprinklers US Patent No. 7,353,882 applies to Model F1 Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model F1 Res 44 SWC Sprinkler Patent Pending - Model F1 Res 76 Pendent Sprinkler Product Description Model F1Res Pendent sprinklers (Figs. 1, 2, 3 & 4) combine excellent durability, high sensitivity glass-bulb and low profile decorative design. F1 Res 44 SWC F1 Res 58 HSWX 2. K=7.6) that will provide lower pressure demands for 0.1 gpm/ft2 densities in NFPA 13 residential applica- tions. Example No. 1 Room Size= 12 ft x 20 ft (3.6 m x 6.1 m) Coverage Area= 12 x 20 = 240 ft2 (22.3 m2) Flow @ 0.10 gpm/ft2 density= 240 x 0.10 = 24 gpm Using an F1 Res 49 Pendent Sprinkler, K=4.9 Pressure= (24/4.9)2 = 24 psi (1.65 bar) The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) cover- age area using the baseline density of 0.05 gpm/ft2 will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). There- fore, the minimum flow required is 24 gpm @ 24 psi (90.8 L/min @ 1.65 bar). Example No. 2 Room Size= 8 ft x 20 ft (2.4 m x 6.1 m) Coverage Area= 8 x 20 = 160 ft2 (14.9 m2) Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm Using an F1 Res 49 Pendent Sprinkler, K=4.9 Pressure= (16/4.9)2 = 10.7 psi (0.74 bar) The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) cover- age area using the baseline density of 0.05 gpm/ft2 will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Therefore, the minimum flow required is 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Example No. 3 Room Size= 10 ft x 16 ft (3.0 m x 4.91 m) Coverage Area= 10 x 16 = 160 ft2 (14.9 m2) Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm Using an F1 Res 76 Pendent Sprinkler, K=7.6 The baseline flow for a 16 ft x 16 ft coverage area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the minimum flow and pressure is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Example No. 4 Room Size= 14 ft x 18 ft (4.3 m x 5.5 m) Coverage Area= 14 x 18 = 252 ft2 (23.6 m2) Flow @ 0.10 gpm/ft2 density= 252 x 0.10 = 25.2 gpm (94.6 L/min) Using an F1 Res 76 Pendent Sprinkler, K=7.6 Pressure= (252/7.6)2 = 11 psi (0.76 bar) The baseline flow and pressure of an 18 ft x 18 ft cover- age area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the minimum flow and pressure is 25.2 gpm @ 11 psi (94.6 L/min @ 0.76 bar). In general residential sprinklers require fl ows and pressures as listed for 0.05 densities to achieve the proper spray pattern so the fl ows and pressures at 0.05 density are the baseline fl ows and pressures. Flows and pressures below the listed 0.05 density shall not be used. Application Model F1 Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The National Fire Protection Association or the approving authority having jurisdiction. When using F1 Residential Sprinklers for systems designed to NFPA 13D or NFPA 13R, use listed area of coverage and minimum flow and pressure requirements shown in Bulletin 135. For systems designed to NFPA 13, use information in this bulletin. The number of design sprinklers shall be the most hydraulically demanding sprinklers as required by NFPA 13. Flows and pressures can not be below the baseline flows and pressures. NFPA 13 For residential sprinkler systems designed to NFPA 13, a minimum density of 0.1 gpm/ft2 must be provided over the “design area” that includes the four (4) hydraulically most demanding sprinklers for the actual coverage areas being protected by the 4 sprinklers. The minimum required dis- charge from each of the four most hydraulically demanding sprinklers shall be the greater of the following: 1. The flow rates given in the Reliable Residential Sprinkler Technical Bulletins referenced in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area (for actual coverage areas less than or between those indicated in the respective technical bulletin, it is re- quired to use the minimum required flow for the next largest coverage area); or 2. A minimum discharge density of 0.1 gpm/ft2 applied over the “design area” consisting of the four most hy- draulically demanding sprinklers for the actual cov- erage areas being protected by the four sprinklers. The maximum dimension of the actual coverage area cannot be any greater than the maximum coverage area indicated in the technical bulletins referenced in Table A. Design Note: Using the As = S x L method to de- termine the sprinkler protection area of coverage in accordance with NFPA 13, apply the 0.1 gpm/ft2 den- sity to this area to determine the minimum required flow. Compare this flow to the minimum 0.05 gpm/ft2 cULus Listed flow for the appropriate coverage area in the technical bulletin for the specific residential sprinkler. If the flow stated in the technical bulletin is less than the calculated 0.1 gpm/ft2 density flow required, the .1 density flow must then be used in the equation Q=KP, solving for P, to establish the mini- mum required pressure using the sprinkler K-factor. Note: In many cases the listed flow of individual resi- dential sprinklers may exceed the required minimum 0.05 gpm/ft2 density. Reliable has available resi- dential sprinklers with larger K-factors (K=5.8 and 3. Installation Models F1 Res sprinklers are to be installed as shown. Model F1, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Mod- el F1 Res sprinklers. Use of any other recessed escutch- eon will void all approvals and warranties. For installing Model F1 Res Pendent sprinklers use only the Model D sprinkler Wrench; for installing Models F1 Res Recessed Pendent, CCP sprinklers use only the Model GFR2 sprin- kler wrench; for installing Model F1 Res recessed HSW sprinklers use only the Model GFR2 Sprinkler wrench. Use of wrenches other than those specified may dam- age these sprinklers. Note: A ‘leak tight” sprinkler joint can be obtained with the following torque: • 3/4” NPT (R3/4) – 14-20 ft-lbs (19 - 27.1 N-m) • ½” NPT (R1/2) – 8-18 ft-lbs (10.8 – 24.4 N-m) Do not tighten sprinklers over maximum recom- mended torque. It may cause leakage or impairment of the sprinklers. F1 escutcheon, 3/4” (19mm) adjustment • Model F1 Res 30, 49, 58 & 76 Pendent • Model F1 Res 30, 49, 58 & 76 Recessed Pendent / F1/F2 Note: See escutcheon table for dimensions. Fig. 1 Fig. 2 **Baseline fl ows and pressures for 0.05 density Defl ector - to - ceiling Maximum 1” (25mm) to 4” (100mm) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6)13 (49) 7.0 (0.48) R3516 14 x 14 (4.3x4.3)13 (49) 7.0 (0.48) 16 x 16 (4.9x4.9)13 (49) 7.0 (0.48) 18 x 18 (5.5x5.5) 17 (64.3)12.0 (0.83) 20 x 20 (6.1x6.1) 20 (75.7)16.7 (1.14) 4. Technical Data: F1 Res 49 Pendent and Recessed Pendent Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm)°F°C°F°C 1/2” NPT (R1/2)7/16” (11)155 175 68 79 175 (12)100 150 38 66 4.92.25 (57) Escutcheon*, F1 or F2, Data: Type Adjustment Inch (mm) “A” Inch (mm) Face of fi tting to ceiling Inch (mm) F1 3/4” (19.0)Min.= 3/4 (19.1) Max.=11/2 (38.1) 3/16 - 15/16 (4.7 - 24.0) F2 1/2” (12.7)Min.= 15/16 (23.8) Max.=11/2 (38.1) 3/16 - 11/16 (4.7 - 17.4) * Note: Escutcheons F1 or F2 may be used with Model F1 Res 49 & 58 Recessed Pendent Sprinkler *Defl ector - to - ceiling Maximum 4” (100mm) to 8” (203mm) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6)15 (57) 9.4 (0.65) R3516 14 x 14 (4.3x4.3) 16 (60.5) 10.6 (0.73) 16 x 16 (4.9x4.9) 17 (64.3) 12.0 (0.83) 18 x 18 (5.5x5.5)19 (72)15.0 (1.0) 20 x 20 (6.1x6.1) 22 (83.2) 20.2 (1.4) *Note: The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth = 7” (178mm) 2. Beam spacing at or greater than 7.5 ft. (2.3m) on center. Technical Data: F1 Res 58 Pendent and Recessed Pendent Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp.K Factor Sprinkler Length Inch (mm) °F°C°F°C ½” NPT (R½)½” (13)155 175 68 79 175 (12)100 150 38 66 5.82.25 (57) **Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Ceiling -to-Defl ector Inch (mm) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6)16 (61) 7.6 (0.53) 1-4 (25-100)R3513 14 x 14 (4.3x4.3)16 (61) 7.6 (0.53) 16 x 16 (4.9x4.9)16 (61) 7.6 (0.53) 18 x 18 (5.5x5.5)19 (72) 10.8 (0.75) 20 x 20 (6.1x6.1) 22 (83.3) 14.4 (1.0) **Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1Res 30 Pendent and Recessed Pendent (SIN R3511) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm)°F°C°F°C ½” NPT (R½)21/64” (8.2)175 (12)155 175 68 79 100383.02.25 (57) **Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spac- ing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rat- ing (175°F/79°C)Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/ min) Pressure PSI (bar) 12 x 12 (3,6 x 3,6)12 (3,6)8 (30,3)7.0 (0,48)8 (30,3)7.0 (0,48)1 to 4 (25 to 100); ½ recessed using F2 escutcheon 8 (2,4) 14 x 14 (4,3 x 4,3)14 (4,3)10 (37,8)11 (0,76)10 (37,8)11 (0,76) For Ceiling types refer to NFPA 13, 13R or 13D **Calculate for a .10 density but in no case go below the baseline flows & pressures 5. Technical Data: F1 Res 76 Pendent and Recessed Pendent Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F°C°F°C 3/4” NPT (R3/4)17/32 (13.5)155 175 68 79 175 (12)100 150 38 66 7.62.25 (57) Escutcheon*, F1 or F2, Data: Type Adjustment Inch (mm) “A” Inch (mm) Face of fi tting to ceiling Inch (mm) F1 3/4 (19.0)Min.= 3/4 (19.1) Max.=11/2 (38.1)3/16 - 15/16 (4.7 - 24.0) F2 1/2 (12.7)Min.= 15/16 (23.8) Max.=11/2 (38.1)3/16 - 11/16 (4.7 - 17.4) *Calculate for a .10 density but in no case go below the baseline flows & pressures *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6)217.6 (0.53) R7618 14 x 14 (4.3x4.3)217.6 (0.53) 16 x 16 (4.9x4.9)217.6 (0.53) 18 x 18 (5.5x5.5)217.6 (0.53) 20 x 20 (6.1x6.1)239.2 (0.63) • Model F1 Res 30, 49, 58 & 76 Recessed Pendent / FP • Model F1 Res 30, 49, 58 & 76 CCP Pendent Fig. 3 Fig. 4 NOTE: The F1 Res 76 will use a 1” x ¾” reducer. FP push-on/thread-off escutcheon 6. Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent / FP Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pres- sure psi (bar) Max. Ambi- ent Temp. K Factor Sprinkler Length Inch (mm)°F°C°F°C°F°C ½” NPT (R½)7/16” (11)1556813557175 (12)100384.92.25 (57) CCP Options Data: “A” Cover Adjustment Inch (mm) “B” CCP Height Inch (mm) 1/2 (12.7)15/16 (24) 3/16 (4.7)3/4 (19) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6)13 (49) 7.0 (0.48) R3516 14 x 14 (4.3x4.3)13 (49) 7.0 (0.48) 16 x 16 (4.9x4.9)14 (53) 8.2 (0.56) 18 x 18 (5.5x5.5) 18 (68.1)13.5 (0.93) 20 x 20 (6.1x6.1) 20 (75.7)16.7 (1.14) FP Data “A”: FP Position “A” Inch (mm) Max. Recessed 7/16 (11) Min. Recessed 15/16 (24) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for in- stallation in ceilings which have positive pressure in the space above. Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F°C°F°C°F°C ½” NPT (R½)½ (13)1556813557175 (12)100385.82.25 (57) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6)16 (61) 7.6 (0.53) R3513 14 x 14 (4.3x4.3)16 (61) 7.6 (0.53) 16 x 16 (4.9x4.9)16 (61) 7.6 (0.53) 18 x 18 (5.5x5.5)19 (72)10.8 (0.75) 20 x 20 (6.1x6.1) 22 (83.3)14.4 (1.0) *Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1Res 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) CCP Assembly Temp. Rating Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F°C°F°C ½” NPT (R½)21/64” (8.2)175 (12)13557100383.02.25 (57) *Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,6 x 3,6)12 (3,6)8 (30,3)7.0 (0,48)1 to 4 (25 to 100); ½ (13mm) recessed using FP escutcheon 8 (2,4) 14 x 14 (4,3 x 4,3)14 (4,3)11 (37,8)13.4 (0,92) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a .10 density but in no case go below the baseline flows & pressures 7. *Calculate for a .10 density but in no case go below the baseline flows & pressures F1 Res 44 & 58 Recessed HSW/F2 • Model F1 Res 44 & 58 HSW • Model F1 Res 44 & 58 Recessed HSW/F2 Technical Data: F1 Res 44 HSW & HSW/F2 Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F°C°F°C ½” NPT (R½)3/8 (10)155 175 68 79 175 (12)100 150 38 66 4.42.45 (62) Escutcheon, F2, Data: Type Adjustment Inch (mm) Face of Fitting to wall Inch (mm) F21/2 (13)3/16 - 11/16 (4.7 - 17.4) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) “A” Ceiling -to- Defl ector Inch (mm) Sprinkler Temp. Rating °F (°C) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 4 - 6 (101-152) 155 (68)175 (79)12 (45.4)7.5 (0.52) R3531 14 x 14 (4.3x4.3)155 (68)175 (79)14 (53.0)10.2 (0.71) 16 x 16 (4.9x4.9)155 (68)175 (79)16 (60.6)13.3 (0.92) 16 x 18 (4.9x5.5)155 (68)175 (79)18 (68.1)16.8 (1.16) 18 x 18 (5.5x5.5)155 (68)175 (79)19 (72.0)18.7 (1.29) 16 x 20 (4.9x6.1)155 (68)175 (79)23 (87.1)27.4 (1.89) 12 x 12 (3.6x3.6) 6 - 12 (152-305) 155 (68)175 (79)14 (53.0)10.2 (0.71) 14 x 14 (4.3x4.3)155 (68)175 (79)16 (60.6)13.3 (0.92) 16 x 16 (4.9x4.9)155 (68)175 (79)17 (64.4)15.0 (1.04) 16 x 18 (4.9x5.5)155 (68)175 (79)20 (75.7)20.7 (1.43) 16 x 20 (4.9x6.1)155 (68)175 (79)23 (87.1)27.4 (1.89) *Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F°C°F°C°F°C ¾” NPT (R3/4)17/32” (13.5)155 175 68 79 13557175 (12)100 150 38 66 7.62.25 (57) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6)217.6 (0.53) R7618 14 x 14 (4.3x4.3)217.6 (0.53) 16 x 16 (4.9x4.9)217.6 (0.53) 18 x 18 (5.5x5.5)228.4 (0.58) 20 x 20 (6.1x6.1)2510.8 (0.74) 8. Technical Data: F1 Res 44 SWC Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Cover Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) °F°C°F°C°F°C ½” NPT (R½)3/8 (10)1556813557175 (12)100384.42.45 (62) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) “A” Ceiling -to- Defl ector Inch (mm) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 4 - 6 (101-152) 13 (49.2)8.7 (0.60) R3531 14 x 14 (4.3x4.3)14 (53.0)10.2 (0.71) 16 x 16 (4.9x4.9)17 (64.3)15.0 (1.1) 16 x 18 (4.9x5.5)19 (71.8)18.7 (1.13) 16 x 20 (4.9x6.1)23 (87.1)27.4 (1.89) 12 x 12 (3.6x3.6) 6 - 12 (152-305) 14 (52.9)10.2 (0.71) 14 x 14 (4.3x4.3)15 (56.7)11.7 (0.81) 16 x 16 (4.9x4.9)18 (68.1)16.8 (1.16) 16 x 18 (4.9x5.5)20 (75.6)20.7 (1.43) • Model F1 Res 44 SWC Fig. 5 *Calculate for a .10 density but in no case go below the baseline flows & pressures 9. Technical Data: F1 Res 58 HSW & HSW/F2 Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) °F°C°F°C ½” NPT (R½)½ (13)155 175 68 79 175 (12)100 150 38 66 5.82.45 (62) Escutcheon, F2, Data: Type Adjustment Inch (mm) Face of Fitting to wall Inch (mm) F2½ (13)3/16 - 11/16 (4.7 - 17.4) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) “A” Ceiling -to- Defl ector Inch (mm) Sprinkler Temp. Rating °F (°C) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 4 - 6 (101-152) 155 (68)175 (79)16 (60.6)7.6 (0.53) R3533 14 x 14 (4.3x4.3)155 (68)175 (79)18 (68.2)9.7 (0.67) 16 x 16 (4.9x4.9)155 (68)175 (79)21 (79.5)13.2 (0.91) 16 x 18 (4.9x5.5)155 (68)175 (79)25 (94.7)18.6 (1.28) 16 x 20 (4.9x6.1)155 (68)175 (79)29 (109.8)25 (1.73) 12 x 12 (3.6x3.6) 6 - 12 (152-305) 155 (68)175 (79)22 (83.3)14.4 (1.0) 14 x 14 (4.3x4.3)155 (68)175 (79)22 (83.3)14.4 (1.0) 16 x 16 (4.9x4.9)155 (68)175 (79)26 (98.4)20.1 (1.39) 16 x 18 (4.9x5.5)155 (68)175 (79)31 (117.4)28.6 (1.97) *Calculate for a .10 density but in no case go below the baseline flows & pressure 10. Technical Data: F1Res 58 HSWX (SIN RA3533) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) Sprinkler Identifi cation Number (SIN)°F°C°F°C Bulb ½” NPT (R½)1/2” (13)175 (12)155 175 68 79 100 150 38 66 5.82.45 (62)RA3533 *Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/ min) Pressure PSI (bar) 18 x 20 (5,5 x 6,1)18 (5,5)30 (114)26.8 (1,85)30 (114)26.8 (1,85) 4 to 6 (100 to 152); ½ (13) recessed using F2 escutcheon 8 (2,4) 20 x 20 (6,1 x 6,1)20 (6,1)30 (114)26.8 (1,85)30 (114)26.8 (1,85) 16 x 22 (4,9 x 7,3)16 (4,9)33 (125)32.4 (2,23)33 (125)32.4 (2,23) 16 x 24 (4,9 x 7,3)16 (4,9)38 (144)42.9 (2,96)38 (144)42.9 (2,96) 14 x 26 (4,3 x 7,9)14 (4,3)42 (160)52.4 (3,75)42 (160)52.4 (3,75) 18 x 20 (5,5 x 6,1)18 (5,5)35 (133)36.4 (2,5)35 (133)36.4 (2,5) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 16 x 22 (4,9 x 6,7)16 (4,9)38 (144)42.9 (2,96)38 (144)42.9 (2,96) 16 x 24 (4,9 x 7,3)16 (4,9)42 (160)52.4 (3,6)42 (160)52.4 (3,6) 14 x 26 (4,3 x 7,9)14 (4,3)46 (174)62.9 (4,34)46 (174)62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a 0.10 density but in no case go below the baseline floor and pressures. • Model F1 Res 58 HSWX (Bulb) • Model KRes58 HSWX (Link) Fig. 6 Technical Data: KRes58 HSWX (RA3593) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) Sprinkler Identifi cation Number (SIN)°F°C Link ½” NPT (R½)1/2” (13)175 (12)100385.82.45 (62)RA3593 *Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spac- ing Ft (m) Ordinary Temp. Rating (165°F/74°C)Top of Defl ector to Ceiling Inch (mm) Mini- mum Spacing Ft (m) Flow GPM (L/min) Pressure PSI (bar) 18 x 20 (5,5 x 6,1)18 (5,5)29 (109)25 (1,72) 4 to 6 (100 to 152); ½ (13) recessed using F2 escutcheon 8 (2,4) 20 x 20 (6,1 x 6,1)20 (6,1)30 (114)26.8 (1,85) 16 x 22 (4,9 x 7,3)16 (4,9)33 (125)32.4 (2,23) 16 x 24 (4,9 x 7,3)16 (4,9)38 (144)42.9 (2,96) 14 x 26 (4,3 x 7,9)14 (4,3)42 (160)52.4 (3,75) 18 x 20 (5,5 x 6,1)18 (5,5)35 (133)36.4 (2,5) 6 to 12 (152 to 305); ½ (13) Recessed using F2 escutcheon 16 x 22 (4,9 x 6,7)16 (4,9)38 (144)42.9 (2,96) 16 x 24 (4,9 x 7,3)16 (4,9)42 (160)52.4 (3,6) 14 x 26 (4,3 x 7,9)14 (4,3)46 (174)62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a 0.10 density but in no case go below the baseline floor and pressures. 11. Maintenance Model F1 Res 30, 49, F1 Res 58 & F1 Res 76 Sprin- klers should be inspected quarterly, and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Re- move any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause im- proper operation or non-operation. Model F1Res 30, 49 & 58 Pendent Sprinkler Specifi cations Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pen- dent sprinklers engineered to provide a minimum de- sign density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the appli- cable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance list- ing shall be 1” to 8” maximum. Sprinkler frame and de- flector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb con- taining no plastic parts, and having a temperature rat- ing of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 49 & 58, SIN R3516 & R3513 (Bulletin 135). 12. Model F1 Res 30, 49 & 58 Recessed Pendent/F1, Model F1 Res 30, 49 & 58 Recessed Pendent/F2, Model F1 Res 30, 49 & 58 Recessed Pendent/FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s instal- lation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1” to 8” maximum. Sprinkler frame and deflector shall be of bronze frame construction hav- ing a ½” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb contain- ing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.9 (70). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½” adjustment (Model F2)] [with ¾” adjustment (Model F1)] [of push-on and thread off design with ½” adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residen- tial recessed pendent sprinklers shall be Reliable [Model F1 Res 49 & 58 Recessed Pendent/F1] [Model F1 Res 49 & 58 Recessed Pendent/F2] [Model F1 Res 49 & 58 Recessed Pendent/FP] SIN R3516 & R3513 (Bulletin 135). Model F1 Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer’s installa- tion guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with top-loaded ex- truded or cold head cup with 3 mm glass bulb contain- ing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Meth- od of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” cover plate adjustment. Cover plate temperature rating shall be 135°F (57°C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color– specify]. ]. Con- cealed pendent sprinklers shall be Reliable Model F1 Res 49 & 58 CCP, SIN R3516 & R3513 (Bulletin 135). Model F1 Res 44, F1 Res 58 Horizontal Sidewall, F1 Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifi cations Sprinklers shall be [cULus Listed] low flow residen- tial horizontal sidewall sprinklers engineered to pro- vide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in con- formance with the manufacturer’s installation guide- lines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Sprin- kler frame and deflector shall be of bronze frame con- struction having a ½” NPT thread. Water seal assem- bly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (74°C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2” adjustment (Model F2) standard finish should be Bright Chrome and white painted. The F1 Res 58 HSW is also available with low lead frame. F1 Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and F1 Res 44 a nomi- nal K factor of 4.4. Standard finish: [Bronze] [Chrome- plated] [White Polyester] [Special finish– specify]. Residential horizontal sidewall sprinklers shall be Reli- able Model F1 Res 44, F1 Res 58, F1 Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). Model F1 Res 44 & 58 Recessed Horizontal Sidewall Sprinkler Use description for the Model F1 Res 58 horizontal sidewall sprinkler with the following modifications: Re- place “horizontal sidewall sprinkler” with “recessed hori- zontal sprinkler.” Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½” adjust- ment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish– specify]. Resi- dential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 58/F2, SIN R3513 (Bulletin 135). Model F1 Res 76 Pendent Sprinklers shall be [cULus Listed] low flow resi- dential pendent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the list- ed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plat- ed] [White Polyester] [Special finish– specify]. Residen- tial pendent sprinklers shall be Reliable Model F1 Res 76, SIN R7618 (Bulletin 135). Model F1 Res 76 Recessed Pendent/F1, Model F1 Res 76 Recessed Pendent/F2, Model F1 Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residen- tial recessed pendent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer’s technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾” NPT thread. Water seal assembly shall consist of a Teflon-coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½” adjustment (Mod- el F2)] [with ¾” adjustment (Model F1)] [of push-on and thread off design with ½” adjustment (Model FP)]. Stan- dard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 76 Recessed Pendent/F1] [Model F1 Res 76 Recessed Pendent/F2] [Model F1 Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model F1 Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer’s installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” cover plate adjustment. Cover plate tem- perature rating shall be 135°F (57°C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color– specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 76 CCP, SIN R7618 (Bulletin 135). Finishes(1) Standard Finishes SprinklerF1, F2, FP Escutcheons Bronze Chrome Plated White Polyester Coated Brass Bright Chrome Plated White Painted Special Application Finishes SprinklerF1, F2, Escutcheons Bright Brass Black Plated Black Paint Off White Satin Chrome Bright Brass Black Plated Black Paint Off White Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Information Specify:Ordering 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish 13. The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 09/13 P/N 9999970322 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection freedom® residential concealed pendent sprinkler vk474 (k5.8) tecHnical data March 7, 2013 the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com 1. description Viking Freedom® Residential Concealed Pendent Sprinkler VK474 is a small high-sensitivity solder link and lever residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 5.8 (83.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection sys- tem. The fast response operating element and special deflector combine speed of operation and areas of coverage to meet residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to ½” (12.7 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. listinGs and approvals cUlus listed: Category VKKW Refer to the Approval Chart on page 148j and Design Criteria on page 148k for cULus Listing requirements that must be followed. 3. tecHnical data Specifications: Available since 2009. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 5.8 U.S. (83.6 metric*) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. material standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Seat Assembly: Brass UNS-C31600 Compression Screw: Brass UNS-C36000 Fusible Element Assembly: Beryllium Nickel, coated with black acrylic paint Levers: Stainless Steel UNS-S31600 Lever Bar: Copper Alloy UNS-C72500 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene cover plate materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic ordering information: (Also refer to the current Viking price list.) Viking Freedom® Residential Concealed Pendent Sprinkler VK474 and Cover Plate Assembly must be ordered separately: sprinkler: Part No. 15790AC (includes a 165 °F (74 °C) rated sprinkler with a protective plastic cap covering the unit). Form No. F_012109 Replaces page 148h-l, dated February 3, 2012. (Revised Approval Chart format.) viking technical data may be found on the viking corporation’s Web site at http://www.vikinggroupinc.com. the Web site may include a more recent edition of this technical data page. Sprinkler 148h tecHnical data March 7, 2013 the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com freedom® residential concealed pendent sprinkler vk474 (k5.8) cover p late a ssemblies: Base Part No. 13504 (2-3/4” diameter), Base Part No. 13642 (3-5/16” diameter), or Base Part No. 15394 (square cover plate, 3-5/16” diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = /B Temperature Suffix: 135 °F (57 °C) = A For example, cover 13504 with a Polished Chrome finish and a 135 °F (57 °C) temperature rating = 13504FA. available finishes and temperature ratings: Refer to Table 1. accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) sprinkler Wrenches**: A. Heavy Duty Part No. 13623W/B (available since 2006), or B. Head Cabinet Wrench Part No. 13619*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ½” ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. sprinkler cabinet: Part No. 01731A (available since 1971) 4. installation Refer to appropriate NFPA Installation Standards. 5. operation During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the fusible element to disengage releasing the sealing assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability Viking Sprinkler Model VK474 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUarantee For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Sprinkler 148i table 1: available sprinkler temperatUre ratinGs and finisHes sprinkler temperature classification sprinkler nominal temperature rating1 maximum ambient ceiling temperature2 required cover assembly temperature rating cover plate base part no.3 large cover plate base part no.3 square cover plate base part no.3 Ordinary 165 °F (74 °C)100 °F (38 °C)135 °F (57 °C)13504 13642 15394 cover plate finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. freedom® residential concealed pendent sprinkler vk474 (k5.8) tecHnical data March 7, 2013 the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com approval chartviking vk474, 5.8 k-factor residential concealed pendent sprinkler for systems designed to nfpa 13d or nfpa 13r. for systems designed to nfpa 13, refer to the design criteria on page 148k. for ceiling types refer to nfpa 13, 13r or 13d 2013 editions sprinkler base part number 1 sin npt thread size nominal k-factor maximum Water Working pressureinchesmmU.s.metric 2 15790AC VK474 1/2 15 5.8 83.6 175 psi (12 bar) max. coverage area 6 Width X length ft. X ft. (m X m) ordinary temp rating (165 °f/74 °c)Deflector to ceiling installation type listings and approvals 3 minimum spacing ft. (m) flow 6 Gpm (l/min) pressure 6 psi (bar) cUlus 4 nyc nsf 12 X 12 (3.7 X 3.7) 16 (60.6) 7.6 (0.52) Refer to Figure 2 on page 148l Concealed with Cover Plate Assembly See Footnote 7 and 9 See Footnote 5 --8 (2.4) 14 X 14 (4.3 X 4.3) 16 (60.6) 7.6 (0.52) 16 X 16 (4.9 X 4.9) 16 (60.6) 7.6 (0.52) 18 X 18 (5.5 X 5.5) 19 (71.9) 10.7 (0.74) 20 X 20 (6.1 X 6.1) 23 (87.1) 15.7 (1.1) footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria on page 148k. 4 Listed by Underwriter’s Laboratories, Inc. for use in the U.S. and Canada. 5 Meets New York City requirements, effective July 1, 2008. 6 For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 7 Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 13504 1, 13642 1 (large diameter), or 15394 1 (square cover plate). 8 Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 9 Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 8. Sprinkler 148j tecHnical data March 7, 2013 the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com freedom® residential concealed pendent sprinkler vk474 (k5.8) desiGn criteria (Also refer to the Approval Chart on page 148j.) cUlus listing requirements: When using Viking Residential Concealed Pendent Sprinkler VK474 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart on page 148j. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in the Approval Chart on data page 148j for NFPA 13D and NFPA 13R applications for each listed area of coverage, or Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. Minimum distance between VK474 residential sprinklers: 8 ft. (2.4 m). note: concealed sprinklers must be installed in neutral or negative pressure plenums only. • • • important: always refer to bulletin form no. f_091699 - care and Handling of sprinklers. also refer to pages res1-17 for general care, installation, and maintenance information. viking sprinklers are to be installed in ac- cordance with the latest edition of viking technical data, the appropriate standards of nfpa and any other similar authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. final approval and acceptance of all residential sprinkler installations must be obtained from the authorities Having Jurisdiction. Sprinkler 148k figure 1: sprinkler installation and correct Use of Wrenches freedom® residential concealed pendent sprinkler vk474 (k5.8) tecHnical data March 7, 2013 the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com Sprinkler 148l figure 2: sprinkler dimensions and cover installation figure 3: identification of custom paint color for concealed covers figure 4: square cover assembly 15394 Form No. F_012109 tHis paGe intentionally left blank Replaces page 148h-l, dated February 3, 2012. (Revised Approval Chart format.)