Loading...
HomeMy WebLinkAboutA13-0064 plans GOV�l�l\T�N� CO�ES 8c SCOPE OF WORK UPGRADE OF EXISTING EST-3 FIRE ALARM SYSTEM. THE SITE CONTAINS � C O�� Al�TALY S�S 16 APARTMENT BUILDINGS AND A OFFICE BUILDING. THE FIRE ALARM z � � � CONTROL PANEL RESIDES WITHIN THE OFFICE BUILDING. EACH w o i ,n � � � � � � � � � � � �� �� � � � ��� � � APARTMENT BUILDING CONTAINS 6 TO 18 UNITS, EACH UNIT IS � °° � o EQUIPPED WITH A SINGLE HORN NOTIFICATION DEVICE. x � o � � H � � � � GOVERNING CODES TH SS SCOPE OF WORK WILL REPLACE THE NOTIFICATION WIRING BETWEEN w �W w � 2010 NFPA 72 THE OFFICE AND BUILDINGS J,K,L,M,N,O,P. THE EXTERIOR HORN/STROBE z z � 2012 INTERNATIONAL FIRE CODE WILL BE REPLACED ON EACH OF THESE 7 APARTMENT BUILDINGS. THE °o Q 2012 INTERNATIONAL BUILDING CODE EXISTING HORN NOTIFICATION DEVICES WITHIN EACH UNIT WILL REMAIN. °p ox-, �' 2011 NATIONAL ELECTRICAL CODE ���� ����� ��� �� � � PHASE 2: , THIS SCOPE OF WORK WILL REPLACE THE NOTIFICATION WIRING BETWEEN � j THE OFFICE AND BUILDINGS A,B,C,D,E,F,G,H,I. THE EXTERIOR � CODE DATA S � � � � ����� � S HORN/STROBE WILL BE REPLACED ON EACH OF THESE 9 APARTMENT � 0 BUILDINGS. THE EXISTING HORN NOTIFICATION DEVICES WITHIN EACH � � UNIT WILL REMAIN. � OCCUPANCY CLASSIFICATION R2 � NEW CONDUIT BY OTHERS WILL BE TRENCHED BETWEEN BUILDINGS TO NUMBER OF STORIES BUILDING A,C,E,F,G,H,I,J,N,O,P TWO STORIES ABOVE GROUND JUNCTION BOXES. SURFACE MOUNT CONDUIT WILL BE UTILIZED TO GET AROUND BUILDING PERIMETERS. BUILDING B,D,K,L,M THREE STORIES SYSTEM TYPE AND MONITORING � � � �� � � Q ° E Fv�z r� F' ��n wz ��ww ra�o� T I M]B E R R I D �E AP AR T 1VI E N T S FIRE ALARM SYSTEM: ADDRESSABLE SYSTEM w "��z o W�o a E� � "'w�E"° � ,aW�� 1 � 80 N . FRONTAGE ROAD A ��aE�"zA��° � o� �� � WIRING CLASSIFICATION: NAC — CLASS B A a°�„�°.,�a�o�o o� V A L Ey � o L O�t i� o IDC — CLASS B � W�EZ a;o��a��� � xz �������x a ���w���AWwpw.• o z w�"N p� AzA�F��wrzw a" xv'WOF�AC'Fx� �� � ���� ����� � � � � � �����T � � o NOTIFICATION TYPE: TEMPORAL PATTERN z�x"� �o�� l� E (� SYSTEMS GROUP � 00 E . 64TH AVE . � � '� DEl�VER , CO 80 � � � � PH : ( 303 ) � � � — '� � 00 ° � � FAX: ( 303 ) � 50 - 566 '� ' W � �� � ������ � � � ����� � � � o FIRE DEPARTMENT PLAN REVIEW SYSTEMS GROUP � � o � FIRE DEPARTMENT: VAIL FIRE DEPARTMENT w � 8 0 � � . 6 4 T H 11 V L' . JL � 4116 COLUMBINE DRIVE Q o � � a # VAIL, COLORADO 81657-4804 D E NVE R y C � U � � � eJ PH: (970)479-2128 � Q � � PH : ( 303 ) � � � — '� � 00 FH11. ( � � � ) 6 5 0 — 5 6 � '� APPROVED BY: DATE: JL�I �JL�I � ��� ��� � � 1V ���� � � � o (� � Z REVIEW NUMBER: 1 ❑ ADK ELECTPIC 2� ° � � Q PO BOX � �41 3� � � � � AVOI� , CO�ORADO �, � � � PH : ( � '� 0 ) 3 '� 6 - 8165 � Q Q z 0 FIRE DEPARTMENT STAMP � � � �' � W W z ° ; w r� r� �' NICET CERTIFICATION � � � � � .� JOHN BALLMAN � z � � � � SYSTEMS GROUP � W �1 W � � � S00 E. 64TH AVENUE, #17 O� � � � Q O� � (303) 298-7900 p� �, � Z � a z Il�D]EX NICET LEVEL: IV TECHNICAL AREA: FIRE ALARM SYSTEMS � CERTIFICATE NUMBER: #101808 � FO.O COVER PAGE VALID THROUGH: NOVEMBER 1, 2015 �" GENERAL INFORMATION ySTE/I�I S � � � a BUILDING REQUIREMENTS AND CODES Roup � SCOPE OF WORK APPROVED BY: � z DATE: z � F3.0 DIAGRAMS & CALCULATIONS w 0 � � � � F � REVIEW NUMBER: 1 ❑ W � py � Systems Group John Ballman Q z 800 E. 64Th Avenue 2❑ Nicet Fire Alarm systems w � W a 1� LevellV (� � � d � 3� Certification #101808 �, Q � � Denver, CO 80229 Date: 303-298-7900 (Pho e) PROJECT 303-650-5667 (Fax� SHEET TITLE F0 . 0 O - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BUILDINGB - - - - W � o � 18 UNITS � � � o � PHASE 1 � PHASE 2 :� � � �° � � i i i W � W ° °o Qz z � � �, � � I I � I � j I BUILDING P I I S� 1 2 U N I T S B12 LUNITS A C 0 � � �o' o' V� . . � I I I I I I v v BUILDING N BUILDING C I 6 UNITS I 6 UNITS I .�. .0. F, a��„o o x w � � � H v�� � E" �v' i ♦ i ♦ Z U'"_'p� �,�w W C!��E-�F' �W ArWO W VW]W F�"OO.T,W Of�'�ry+ �" L1wE F'O� -T�-�E- � �� V V � �Ex-�O�Ll�Zq0�0 I BUILDING L BUILDING J I B18LUNITSD I � °�x� ��w w��� 18UNIT5 12UNIT5 raa�. � o�zo ao� a. �x E-� W C7E�OC.�h��Upq� I ♦ I ♦ I W 0.:Z Ea C7.'7 f� I �� �� I i�� I O Z��A���W�NZ a W�o'-'w���w�H � x�worEi�r�i� ,�3Fx� zE��'r a.oHx E t/] Q ��r I I I I I I V V V BUILDING I BUILDING F 12 UNITS 12 UNITS � z 0 �o' o' � I I � � I � I I I � BUILDING 0 12 UNITS I o. I � � I I I I � � Q � � 0 � o z z Q o � � a � q ,� d � � � v � BUILDING M I I 18 UNITS �o� BUILDING E I I 12 UNITS I � � � � � r� z z '° w � � BUILDING G � � � o � 6 UNITS W � � � BUILDING M �' �' a I 18 UNITS I .�. I � � � � I I I � � � � °. v v � Q Q � BUILDING H � � � �, 6 UNITS � W W z ° � I :�; I � � � � � � � � � I FACP I � � � `� 'y � � OFFICE � � � z � � � � w — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — � W Q w � � w Supply Voltage&Battery Periods a � � Z � a Z ,Zo VAC Supply Voltage � NAC - 0 N E L I N E D I AG RAM FACP 24 Standby Hours SCALE: NONE 5 Alarm Minutes QTY. Model Description Stby mA Alm mA W External Loads for THIS NODE only,Current in mA � 14400 NAC Alarm Current 14400 �.., QTY. Model Description Stby mA Alm mA P H AS E 1 P H AS E 2 � � 1 3-CPU3 Central Processor Module 155 165 � Z 5 3-IDC 8/4 Hardwired Initiating Device Circuit Module 265 1750 � � 1 3-SSDC1 Signature Driver Controller(LRM) 144 204 JBOX TYP) _ �ONDllIT S.UBFACE MOUNT AROUND B1llLDINCi � � 1 3-MODCOM Modem Communicator and Dialer 60 95 d � 1 3-LCD Liquid Crystal Display Module 40 42 �y � 1 3-PPS/M Primary Power Supply(Induded in 3-CPU3 Current) 0 0 1 3-BPS/M Booster Power Supply 50 50 P N L J I F D Z � � TRENCH BETWEEN � U O 2 3-12SG Control Display Module,12 Switches,12 Led's(Green) 40 40 � W 1 3-24R LED Display Module,24 Red LED's 38 38 BUILDINGS A N a x � � � U C� � U] EW-� � U� U� TOTAL LOAD 792 16784 I I R I Q � � � v Z � W Total Stand-By and Alarm Current 792 16784 John Bdllmdn � � C7 '� � M K OFFICE H G E Nicet Fire Alarm Systems � � � U Standby Hours'Total Standby Current 19008 Level IV � Q Q � (Alarm Minutes/60)`Total Alarm Current 1398.667 — — _ _ _ _ _ _ _ _ _ _ _ _ Certification#101808 Date: PROJECT TotalStandby/AlarmCurrent 20406.667 �� NA� - CONDUIT ROUTING SHEET Battery De-Rating Factor+20� 24488.000 24.49 Calculated Battery Ampere Hours � TITLE 2 12V26A 26 AH Battery SCALE: NONE F3 . 0 PRODUCT DATA SHEETS FIRE ALARM DETECTION SYSTEM Timber Ridge Apartments 1280 N. Frontage Road Vail, CO John Ballman Nicet Fire Alarm systems Level IV Certification #101808 Date: SYSTEMS GROUP, LLC 14818 West 6t" Avenue Unit 6A Golden, CO 80401 Phone: (303) 298-7900 Fax: (303) 650-5667 YS7EM,� ROUP Model# Description Cat.Sheet# 757-7A-T 15/75cdWC Strobe, Horn 97 dbA Avg., Red 85001-0341 10/1I2013 Page 1 Of 2 YS7EM,� ROUP 10/1I2013 Page 2 Of 2 Strobes, Horns, Bells,Chimes �� �TM Life Safety & Communications Tem oral Horns p and Horn -strobes *' 1� F' � � � � 757 Series � � � �; . I �� R ' �� � - E � ! � ` � � �I��� � �� i� �, , � .� � . � _ 1 �� , �� '� -- � � '�� 'd ' �, � ���� M EA (E � �C FM . � 000 Patented Overview Standard Features Integrity temporal horns and temporal horn-strobes are specially • UL 1971-listed synchronizing strobe designed for use with compatible life safety communication and Integrity strobes synchronize to the latest UL 1971 require- control equipment to alert occupants of a life safety event. The ments when used with a synchronization source. horn emits a piercing low frequency sound that is easily heard qdjustable Audible Output above moderate ambient noise levels.The flash from its strobe • Select temporal or continuous tones, and High setting for 98 can be noticed from almost any position in the room, corridor, or dBA output or Low setting for 94 dBA sound output. large open space. • Genesis-compatible Integrity's rugged plastic housing is made from durable and fire All Genesis and Integrity strobes on the same circuit meet UL retardant, high impact plastic with a slightly textured surface. Its 1971 synchronization requirements when used with an external ingenious mounting plate firmly holds the device in place with a control module. single screw.A separate trim plate is not required.Terminals ac- cept up to#12 AWG (2.5mm2)wire for polarized connections. • Approved for public and private mode applications UL 1971-listed as signaling devices for the hearing impaired Strobes are shipped with standard wall mount style"FIRE" lens and UL 1638-listed as protective visual signaling appliances. markings. Where ceiling orientation, other languages, or different lens markings are required, Edwards offers optional LKW and LKC • Durable red or white Noryl front plate series Lens Marking Kits.These optional lens markings simply Ideal for outdoor, industrial or harsh environments. snap on to the strobe. Consult Edwards for availability of special . Field changeable field markings lens markings. Lens language or standard "FIRE" marking is easily changed Integrity horns and horn-strobes are designed for 16 to 33 Vdc with optional LKW and LKC series lens kits. operation and must be connected to signal circuits that output a • Easy Installation constant(not pulsed)voltage.A diode is used to allow full signal Flush mount to standard North American 4"square or two- circuit supervision. gang box. Integrity's universal mounting plate allows it to be wired and then left hanging free for easy inspection and testing before it is fastened to the electrical box. Page 1 of 6 05�0�-0341 Issue 6 Application NOTE:The installation of visible and audible signals are subject to national and local standards,codes,and ordinances. Consult your Authority Having Jurisdiction for device installation requirements,application standards,and minimum performance specifications. Horns Strobes During installation, the horn is configured for steady or temporal Edwards strobes are UL 1971-listed for use indoors as wall-mounted tone signal and either low(94 dBA)or high (98 dBA)output.When public-mode notification appliances for the hearing impaired. Prevail- temporal output is selected all horns on a common two-wire ing codes require strobes to be used where ambient noise conditions circuit are self-synchronized (see specifications). External control exceed specified levels, where occupants use hearing protection, modules are not required for audible synchronization. and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. Suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15dB above the average ambi- As part of the Enhanced Integrity line of products, 757 Series ent sound level, or 5dB above the maximum sound level having a strobes exceed UL synchronization requirements(within 10 mil- duration of at least 60 seconds,whichever is greater, measured liseconds other over a two-hour period)when used with a syn- 5' (1.5m)above the floor.The average ambient sound level is the chronization source. Synchronization is important in order to avoid RMS,A-weighted sound pressure measured over a 24-hour period. epileptic sensitivity. Doubling the distance from the signal to the ear will theoretically result Integrity strobes are fully compatible with Edwards Genesis sig- in a 6 dB reduction of the received sound pressure level.The actual nals. effect depends on the acoustic properties of materials in the space.A 3 dBA difference represents a barely noticeable change in volume. NOTE:The flash intensity of some visible signals may not be adequate �utput An le - Deg e� to alert or waken occupants in the protected area. Research indicates g r S that the intensity of strobe needed to awaken 90%of sleeping persons -1 � 15 is approximately 100 cd.Edwards recommends that strobes in sleeping -30 30 rooms be rated at at least 110 cd. -45 5 WARNING:These devices will not operate without electrical power.As -60 60 fires frequently cause power interruptions, further safeguards such as , backup power supplies may be required. -75 `�� � / 75 -90 90 105 95 85 75 dBA 75 85 95 105 Temporal Horn (dBA) Typical Sound Output Distribution dBA measured at 10 ft in anechoic chamber 757 Series Temporal Horn(`HIGH'output) Installation and � North American 2-gang electric box,23/a"(69mm)minimum Mounting � � m 2A1t�$n(54mm)deep)e box All models fit to a standard flush Mounting Plate(provided) � � mounted, North-American two- o gang electrical box, 23/ inch (69 0 � m mm) minimum. Optional flush � trims are not required. For sur- O face mount, use EST's custom indoor and outdoor surface boxes � painted in color-matched red or white epoxy. Edwards recom- � mends that fire alarm horn/strobes always be installed in accordance #6-32 screws(by others) Surface Box-5-5/8"(143mm)sq.x with the latest recognized edi- Housing 3-9/16"(91mm)deep tion of national and local fire alarm / 5-1/2"(140mm)x 5-1/2"(140mm)x 5/8"(16mm) codes. � Single Mounting Screw(provided) Page 2 of 6 05���-034� Issue 6 Typical Wiring Strobe Operating Current (RMS) The strobe must be connected to signal circuits which output UL a constant(not pulsed)voltage.The horn can be connected to Rating 15 cd 15/75 cd 30 cd 75 cd 110 cd continuous voltage circuits. 16 Vdc ios iso iso 263 329 16 Vfwr 150 210 189 333 420 HORN and STROBE FIRST oEVICE ON SAME CIRCUIT Horn/Stro6e Horn/Strohe TypiCal To uuu�c usted Current 15 cd 15/75 cd 30 cd 75 cd 110 cd Fire Alarm Control H+ H+ 24 VdC 69 90 89 159 180 Panel Signal Circuit H- H- . . _ s+ s+ 24 Vfwr 108 128 134 255 � 260 S- S- To Next�evice - ' — � — — or EOL Resisior + Vdc:Volts direct current,regulated and filtered HORN and STROBE _ ON SEPARATE CIRCUIT Vfwr Volts full wave rectified FIRST DEVICE + To UUULC Listetl + To NeM�evice Fire Alarm Contral HorNStro6e Harn/Stm6e or EOL Resistor Current Draw Notes and Comments Panei siqnai Circuit 1. Current values are shown in mA. H+ H+ H- H- 2. UL Nameplate Rating can vary from Typical Current due to measurement meth- To uUU�C�isted + s+ s+ ods and instruments used. Fire Alarm Control- s- S- To Ne#Strobe Device Panel Siqnai Circuit or eo�Resisror 3. Edwards recommends using the Typical Current for system design including NAC ' and Power Supply loading and voltage drop calculations. + 4. Use the 16 Vdc RMS current ratings for filtered power supply and battery AH calculations.Use the 16 Vfwr RMS current ratings for unfiltered power supply calculations. 5. Fuses,circult breakers and other overcurrent protection devices are typically rated for current in RMS values.Most of these devices operate based upon the heating affect of the current flowing through the device.The RMS current dBA Output Horn-strobes � UL464 Average-anechoic Peak-anechoic Temporal Steady Temporal Steady Temporal Steady High dB Output 79.0 85.0 97.0 97.0 102.0 102.0 Low dB Output 75.0 79.0 � 93.0 93.0 98.0 98.0 determines the heating affect and therefore,the trip and hold threshold for those Horns UL464 � Average-anechoic � Peak-anechoic Temporal Steady I Temporal Steady Temporal Steady High dB Output 82.0 85.0 98.0 98.0 104.0 104.0 Low dB Output 75.0 82.0 � 94.0 94.0 99.0 99.0 dBA Output Notes and Comments • All values shown are dBA measured at 10 feet(3.01 m). • UL1480 values measured in reverberation room. • Average values are measured in anechoic chamber. Page 3 of 6 85001-0341 Issue 6 Light Output Patterns 15 cd(-SA)Series Strobes 15/75 cd(-7AI Series Strobes 30 cd(-3A)Series Strobes 75 cd(-4A)Series Strobes 110 cd(-8AI Series Strobes HorizontalOutput Horizontal0utput Horizontal0utput Horizontal0utput HorizontalOutput degrees degrees degrees degrees degrees 30-15 � 5 30 -30-15 � 5 30 -30-15 � 5 30 -30-15 � 5 30 -30 1� O � 5 30 -45 � 45 -45 � 45 -45, i 45 -45 45 -45 � � � ,45 -60 `� ���I �� / ' 60 -60 % 60 -60 �� �� i 60 -60 i �I i !��' 60 -60 � U �60 -75 75 -75 � j . �"75 JS 75 -75 ;75 -75 75 -90--'--- 90 -90 —90 -90 90 -90 ' — = 90 -90- — -90 30 20 10 cd 10 20 30 100 50 cd 50 100 60 40 20 cd 20 40 60 140 100 60 cd 60 100140 200 100 cd 100 200 Vertical Output Vertical Output Vertical Output Vertical Output Vertical Output -90-75 -90_75 -90_75 -90_75 -90_75 30 -60 100 -60 60 -60 14� -60 150 -60 -45 -45 � -45 - - -45 -45 �� � �,-30 i�-30 40 �.-30 100 -30 100 -30 SO �� 10 -15 a -15 a 20 -15 a 60 ' -15 a 50 -15 a c d - a � c d � � c d � � c d 0 tO c d 0 `° - %� 10�� � 15 N 15 y zp 15 y 60-� 15 y 5� 15 � 50 - � 20 ��..��4530 - 1 \ 4530 40 I 4530 100 ;� 4530 100- 45� 30 90�75 60 100 gp 75 60 60 g�75 60 140 90 75 60 150 75 60 90 Q Averoge UL min 0 QAVerage UL min 0 QAverage UL min� QAverage UL min 0 QAVerage UL min� Vertical _gp� _gp^ 90° Horizontal Specifications 90� Rated Strobe Output-candela I 757-1A-T I 757-5A-T I 757-7A-T 757-3A-T I 757-4A-T I 757-8A-T (cd) UL 1638 15 conly�oor 75 cd 30 cd 75 cd 110 cd UL 1971 N/A (horn only) 15 cd 15 cd wall 30 cd wall 75 cd wall 110 cd wall (wall mount only) 15 cd ceiling 15 cd ceiling 60 cd ceiling 60 cd ceiling ULC S526 15 cd 75 cd 30 cd 75 cd 120 cd Standalone Synchronization Strobe flash at 1 per second within 200 milliseconds on common circuit Horn pulses at temporal rate Characteristics(note 2)� within 200 milliseconds on common circuit _ Operating Volts Strobe: 16-33 Vdc or Vfwr Continuous Horn: 16-33 Vdc or Vfwr Continuous Anechoic:High Setting- 104 dBA(peak)/98 dBA(avg); Low Setting-99 dBA(peak)/94 dBA(avg) Horn Output(note 1) Reverberent: High Setting-85 dBA(continuous)/82 dBA(temporal); Low Setting-82 dBA(continuous)/75 dBA(temporal) Horn Current High Output:40 mA @ 24 Vdc;55mA @ 24 Vrms FWR Low Output:20 mA @ 24 Vdc; 28 mA @ 24 Vrms FWR Strobe Flash Synchronization Synchronized at one flash per second. External control module necessary to meet UL 1971 synchronization requirements of 10 milliseconds over a two hour period. Synchronization Sources G1 M-RM,SIGA-CC1 S,SIGA-MCC1 S, BPS6A, BPS10A Strobe Marking Supplied with LKW-1 "FIRE°red letters,vertical both sides(Wall Mount) -see LKW and LKC series for ceiling style and optional markings. Flash Tube Enclosure Clear LEXAN with white marking sleeve Housing I Textured,color impregnated engineered plastics-exceeds 94V-0 UL flammability rating Wire Connections �- Terminals-separate,polarized inputs for Horn&Strobe,#12 AWG(2.5mm2)maximum INDOOR Operating Environment I 32-120°F(0-49°C)ambient temperature.93%relative humidity @ 40°C 98%relative humidity @ 40°C; -31-150°F(-35-66°C)ambient temperature OUTDOOR Operating Environment (757-4A: rated at 48 cd @-35°C per UV@-40°C per ULC) (must use weatherproof box) (757-7A: rated at 17.7 cd @-35°C per UUQ-40°C per ULC) (757-8A: rated at 70.7 cd @-35°C per UU@-40°C per ULC) Mounting INDOOR Rush: North-American 2-gang box,3"high x 4"wide x 23/4"(69 mm)minimum Surface:757A SB Back box Bi directional:757A-BDF Mounting Frame Mounting-OUTDOOR Surface:757A-WB Weatherproof Box Agency Listings UL 1971, UL 1638,UL 464, ULC S526, ULC S525, MEA,CSFM, FM.CE (All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule) Note 1-Measured at 10 ft(3m)Q 24 Vdc.Subtract 3 dBA for models with strobes.Note 2-Temporal audible pattern is defined as:�/2 sec ON,Yz sec OFF,Y2 sec ON,Yz sec OFF,Yz sec ON,1�/z sec OFF,then repeat cycle.Integrity audible will not be affected by Genesis signal silence operation when on the same two wire circuit with Genesis horn strobes. Page 4 of 6 05���-0341 Issue 6 Ordering Information Catalog Ship Wt., LKW-1 °FIRE",Wall Orientation(supplied) Number Description Ib.(kg) LKW-1 R °FIRE°,Wall Orientation, RED LKW-2 "FEU",Wall Orientation Temporal Horns LKW-3 °RRE/FEU",Wall Orientation 757-1A-T' Temporal Horn,Red 1.7(0.8) LKW-4 "SMOKE°,Wall Orientation 0.1 (.05) LKW-5 "HALON",Wall Orientation Temporal Horn-Strobes LKW 6 "CO2",Wall Orientation 757-7A-T' Temporal Horn-Strobe, 15/75cd, Red LKW-7 "EMERGENCY",Wall Orientation 757-5A-T` Temporal Horn-Strobe, 15cd, Red LKW-8 "ALARM",Wall Orientation 757-3A-T` Temporal Horn-Strobe,30cd, Red 2.0(0.9) LKW-9 °FUEGO",Wall Orientation 757-4A-T' Temporal Horn-Strobe,75cd, Red Add suffix"w"to catalog no.for wHITE(e.g. 757-7A-7VI/) 757-8A-T` Temporal Horn-Strobe, 110cd, Red Change"W"to"C'for CEILING mount(e.g.LKC-1) Synchronization Sources G1 M-RM g ng)sis Signal Master Remote Mount(1 0.2 (0.1) SIGA- Synchronization Output Module(Standard 0.5 (0.23) CC1S Mount)-UVULC Listed SIGA- Synchronization Output Module(UIO Mount) 0.18 (0.08) MCC1S -UL Listed BPS6A 6.5 Amp Booster Power Supply 13(5.9) BPS10A 10 Amp Booster Power Supply 13(5.9) Mounting Accessories 757A-SB` Surfiace Box, Red, Indoor 1.5(0.7) 757A WB� Weatherproof Box, Red,Surface 757A-BDF" Bi-directional Frame, Red 4(1.8) 'Add-W for White housings. Lens Marking Kits(see note 1) Page 5 of 6 85001-0341 Issue 6 �p���,��� 4� A UTC Fire&Security Company Detection&alarm since 1872 U.S. T 888-378-2329 F 866-503-3996 Canada Chubb Edwards T 519 376 2430 F 519 376 7258 Southeast Asia T:+65 6391 9300 F:+65 6391 9306 India T:+91 80 4344 2000 F:+91 80 4344 2050 Australia T+61 3 9239 1200 F+61 3 9239 1299 Europe T+32 2 725 11 20 F+32 2 721 86 13 Latin America T 305 593 4301 F 305 593 4300 utcfi rean d sec u rity.c om OO 2010 UTC Fire&Security. All rights reserved. 0 N Page 6 of 6 oSOO�-034� � Issue 6