Loading...
HomeMy WebLinkAboutDRB130490 APPLICATION Project Name:LANGENAUER SLIDING PATIO DOOR DRB Number: DRB130490 Project Description: REMOVE EXISTING WINDOW AND PUT IN SLIDING PATIO DOOR. Participants: OWNER LANGENAUER, ROBERTO 10/14/2013 POETAS 100 CASA 6 MANZANA 2 CUAJIMALPA DE MORELOS MEXICO 05600 APPLICANT CROSSROADS REALTY 10/14/2013 Phone: 970-476-4300 AKA: DGN INC 1650 FALLRIDGE ROAD VAIL CO 81657 License: C000003121 CONTRACTOR CROSSROADS REALTY 10/14/2013 Phone: 970-476-4300 AKA: DGN INC 1650 FALLRIDGE ROAD VAIL CO 81657 License: C000003121 Project Address:1588 GOLF TERRACE VAILLocation: GOLF COURSE TOWNHOMES UNIT 41 Legal Description:Lot: 1 Block: Subdivision: SUNBURST FILING 3 Parcel Number:2101-091-0404-1 Comments:See Conditions BOARD/STAFF ACTION Motion By: Action: STAFFAPP Second By: Vote: Date of Approval: 10/31/2013 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS. Cond: 202 (PLAN): Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Cond: CON0013470 The applicant shall apply stucco (to match the existing) to the portion of the south facade exposed from excavating dirt for the new patio. Planner:Joe Batcheller DRB Fee Paid: $20.00 *****�*********+*********************************************+++**************************** TOWN OF VAIL, COLORADOCopy Reprinted on 10-15-2013 at 08:43:55 10/15/2013 Statement ****************************�*******************************************************+******* Statement Number: R130001710 Amount: $20.00 10/15/201308: 43 AM Payment Method:Credit Crd Init: CG Notation: visa 1 nobrega ----------------------------------------------------------------------------- Permit No: DRB130490 Type: DRB-Chg to Appr Plans Parcel No: 2101-091-0404-1 Site Address: 1588 GOLF TERRACE VAIL Location: GOLF COURSE TOWNHOMES UNIT 41 Total Fees: $20.00 This Payment: $20.00 Total ALL Pmts: $20.00 Balance: 50.00 **********+***++******************+**++****+*+**+*+*****+++****************+*+************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ DR 00100003112200 DESIGN REVIEW FEES 20.00 ----------------------------------------------------------------------------- /��� \�_...�,��' V D Department of Community Development 75 South Frontage Road TOWN OF VAIL OCT 14 2013 Vail, CO 81657 1� Tel: 970-479-2128 f� www.vailgov.com TOWN OF VAIL Development Review Coordinator Application for Design Review Changes to Approved Plans General Information: This application is for all changes to approved plans prior to Certificate of Occupancy. An applica- tion for Design Review cannot be accepted until all required information is received by the Community development De- partment. Design Review approval expires one year from the date of approval, unless a building permit is issued and construction commences. Submittal Requirements: The Town of Vail offers two (2) methods for submittal of materials for review of applications. Materials can be submitted either digitally or on paper. Whichever method you select all materials shall be submitted in that format throughout the Design Review process. The Town encourages you to consider using the submittal of digital documents and plans. If submitting digitally all elements of the application shall be uploaded to the Town's share file site as a complete set of materials. If submitting paper three (3) copies of the materials noted with an asterisk(") and one (1) copy of all others are required. The materials necessary to have a complete application are as follows: 1. Copies of all pertinent approved plans with illustrated, labeled changes. 2. Joint Property Owner Written Approval Letter, if applicable. Fee: $20 ❑ Single Family ❑ Duplex Multi-Family El—Commercial Description of the Request: mot, h S L)T- 0 D Physical Address: Parcel Number: 2 10 011 -OLF- 61C t' (Contact Eagle Co. Assessor at 970-328-8640 for parcel no.) Property Owner: e✓1 V?-- Mailing Address: 1 Sy,eO C,F -7,�, - 14 Q 194,"1 Phone: Owner's Signature: Primary Contact/Owner Representative: 1 Mailing Address: ((p5D ��1�V21 Phone: 01'10—'3()(0`>?3 E-Mail: at IAiL ,LO N-\ Fax: For Office Use Only: Cash_ CC: Visa/MC Last 4 CC# Exp. Date: Auth # Check# Fee Paid: Received From: Meeting Date: l k-(KQ-1') D R B No.: O 14 go Planner: Project No: 3 - as Zoning: Land Use: Location of the Proposal: Lot: _Block: Subdivision: SUS ALMST -I L I q&, Architect Series` Pella' Pro Line GLAZING PERFORMANCE - TOTAL UNIT CONTEMPORARY Clad Contemporary SLIDING PATIO DOOR Shaded Areas Meet ENERGY STAR' o U o Performance Criteria in Zones Shown Type of Glazing m (D it LL N > U U.S. Canada2 Zone ER Zone DOUBLE-PANE 3mm clear with 3mm clear HGP 0.49 0.56 58 43 3mm clear with 3mm Low-E HGP 0.39 0.53 54 51 3mm SolarETM with 3mm clear HGP 0.40 0.34 39 50 TINTED GLAZING 3mm bronze with 3mm clear HGP 0.49 0.45 43 43 3mm bronze with 3mm Low-E HGP 0.39 0.41 40 51 3mm gray with 3mm clear HGP 0.49 0.42 39 43 3mm 2ray with 3mm Low-E HGP 0.39 0.38 36 51 5/8"clear with 3mm clear HGP 0.36 0.50 53 56 23 5/8"clear with 3mm Low-E HGP 0.31 0.47 50 57 1 128 5/8"Advanced Low-E IG with argon with 3mm clear HGP 0.27 0.25 45 59 20 5/8"Advanced Low-E IG with argon with 3mm Low-E HGP 0.25 0.24 42 59 22 5/8"NaturalSun Low-E IG with argon with 3mm clear HGP 0.28 0.45 51 59 30 5/8"NaturalSun Low-E IG with argon with 3mm Low-E HGP 0.25 0.43 48 59 33 5/8"SunDefenseT1 Low-E IG with argon with 3mm clear HGP 0.27 0.19 42 59 16 5/8"SunDefense Low-E IG with argon with 3mm Low-E HGP 0.25 0.18 39 59 18 5/8"SunDefense Low-E IG with argon with 4mm clear HGP 0.28 0.19 41 58 15 5/8"SunDefense Low-E IG with argon with 4mm Low-E HGP 0.26 0.18 39 59 17 5/8"bronze Advanced Low-E IG with argon with 3mm clear HGP 0.29 0.21 29 58 15 5/8"bronze Advanced Low-E IG with argon with 3mm Low-E HGP 0.26 0.20 27 58 18 5/8"gray Advanced Low-E IG with argon with 3mm clear HGP 0.29 0.20 25 58 15 5/8"gray Advanced Low-E IG with argon with 3mm Low-E HGP 0.26 0.18 23 58 17 5/8"green Advanced Low-E IG with argon with 3mm clear HGP 0.29 0.21 35 58 15 5/8"green Advanced Low-E IG with argon with 3mm Low-E HGP 0.26 0.19 33 58 18 5/8"Advanced Low-E HA IG with 3mm clear HGP 0.30 0.25 45 58 16 5/8"Advanced Low-E HA IG with 3mm Low-E HGP 0.27 0.24 42 58 19 5/8"Advanced Low-E HA IG with 4mm clear HGP 0.31 0.24 44 58 14 5/8"Advanced Low-E HA IG with 4mm Low-E HGP 0.28 0.23 42 58 17 5/8"NaturalSun Low-E HA IG with 3mm clear HGP 0.30 0.44 51 58 27 5/8"NaturalSun Low-E HA IG with 3mm Low-E HGP 0.27 0.42 48 58 30 5/8"NaturalSun Low-E HA IG with 4mm clear HGP 0.32 0.43 51 58 24 5/8"NaturalSun Low-E HA IG with 4mm Low-E HGP 0.28 0.40 47 58 27 Climate Zones R-Value=1/1.-Factor See the Product Performance section for more a AX SHGC=Solar Heat Gain Coefficient detailed information or visit www.energystar.gov Al VLT%=Visible Light Transmission for Energy Star guidelines. CR=Condensation Resistance ER=Canadian Energy Rating + (1)Glazing performance values are calculated based on NFRC 100. (2)The values shown are based on Canada's updated ENERGY STAR's initiative. I' For center-glass values,see the Product Performance section. "•,,. A Rev.03/30/2013 Pella 2013 Architectural Design Manual I Division 08-Openings I Windows and Doors www.PellaADM.com W-SD-10 Architect Seriesl� MMM Pella' Pro Line �I b' 7-1/2" SIZE TABLES H CONTEMPORARY Aluminum-Clad Wood SLIDING PATIO DOOR Opening 2'71/27 (soo) 3'11 112" (953) 4'11 1127 (1 257) Frame 2'63/4" (781) 3'03/4" (933) 4'03/4" (1 238) N Of O O N N � n ED ED FIXED(0) FIXED(0) FIXED(0) 3180 3780 4980 Opening 5-0- (1 524) 6'0" 8'0" (2 438) Frame 4'11111W (1 505) 7'111/4" (2 419) N � O O N N "N 00 N FIXED-VENT( ) FIXED-VENT(OX) FIXED-VENT(OX) 6080 7280 9680 Opening 7'63/4" (2 305) 9'0314" (z 7s2) 12'03/4" (3 677) Frame 7-6- (2 286) 910. (2 743) 12-0- (3 658) N O O O N N I I I "N ED 3 PANEL(OXO) 3 PANEL(OXO) 3 PANEL(OXO) 9080 10880 14480 Opening 9'87/e" (2 969) 11'871e" (3 578) 15'87/8" (4 797) Frame 9'81/8" (2 950) 11'81/e" (3 559) 15'81/8" (4 778) N O O O N N CD f, {D tO 4 PANEL(OXXO) 4 PANEL(OXXO) 4 PANEL(OXXO) 11780 14180 18980 W-SD-50 Pella 2013 Architectural Design Manual I Division 08-Openings I Windows and Doors www.PellaADM.com Designer Series Sliding Patio Door I Pella.com Page 1 of 20 MENU - Designer Series@ Sliding Patio Door v Designer Series° Sliding Patio Door Explore Door Styles > Sliding Patio Doors Designer Series° Sliding Patio Door (Designer Series® 7S0) �mom Please hover over the large image above for more detail. Features • Removable between-the-glass blinds,shades,decorative panels and grilles • Up to 74%more energy efficient with triple-pane glass' • Better draft protection-sliding panel on the outside for a tighter seal • Self-closing InView®or RolscreeO retractable screen options VIEW ALL DOOR OPTIONS>> Where to Buy https://www.pella.com/doors/explore-door-styles/door.aspx?type=designer-series-sliding-... 10/11/2013