Loading...
HomeMy WebLinkAboutB13-0475� . i . „� k�� � � � _.. � �-- � . �. ___ _ \ — — , � __ � � o � � I �i� �v � i I � i � / I I � I UNIT 108 i � I � � I � � � � I i � I i � KEY PLAN ��,-; .>a,� :..,, . ,,.. i 2 SCALE: 1" =100' tl � � BUILDING CODE DATA: I I CONSTRUCTION TYPE: Type IIIA II OCCUPANCY: R-2 II I I BUILDING STORIES/ HEIGHT: 5 Stories II_ _ _ � � - — — DEMO WALL& SPRINKLER SYSTEM: I DOOR FOR NEW Full S rinklered re: NFPA 13 and IBC 903.3.1 I I I POCKET DOOR y p I� � ' FIRE RATINGS: � � Walls separating dwelling units shall be 1 hr. rated � Floor ceiling assemblies between units 1 hr. rated � � �- — — L r- — — — —r � I Scope of Work: � Work for this Building Permit shall be limited to the interior tenant finish / _ � _ � � at the existing condominium unit.All work shall be within the existing \ � � I envelope of the building.The scope of work shall include new electrical, � I � � � piumbing fixtures,interior partitions and tinishes on this sheet.All � � � modifications and additions are non structural. I� I � � � 1 �'— r-� I � Demo Notes: I � �� � DEMO SAUNA. 1.Demo all existing plumbing fixtures except where otherwise indicated. �� _ � I r� � � I — 2.Demo all existing cabnetry except where otherwise noted. DEMO EXISTING 3.Demo all existing interior doors,frames,and casing except where TILEAND PLUMBING otherwise noted. — � — —� 4.Demo all exisitng floor finishes except where noted otherwise s- — — — FIXTURES << � � � I_ _ � _�I_ _ S.Save and protect for re-use all existing finishes not to be demolished. ( ) ( ) I_ _ I� ��— — — � DEMO EXISTING General Unit Notes: WALLS AND 1.Dimensions are to face of stud,face of concrete,or column centerline DOORS unless noted otherwise. 2.All penetrations of rated walls,floor,or ceiting assemblies must be fire caulked per UL listings. 3.All wet areas are to receive 5/8"thick water resistant gypsum board. _ _ _ _ _ _ - — � 4.Provide blocking as required for cabinetry,built-ins,etc. 5.Existing sprinkler heads and fire protectiou system to remain. Protect as required. _ _ � 6.Typical door jamb opening shall be a minimum of 3"from the corner of — — — — — — — the adjacent wall. DEMO EXISTING 7•All new interior non-rated partitions are assumed to be 3 1/2"wood � � � r �(j KITCHEN CABS studs with 5/8"gwb. each side unless otherwise indicated. n � AND APPLIANCES 8. Patch and repair existing wall board as required. � � � Plumbing Notes: 1. Connect new plumbing fixtures to existing waste lines. Penetrations of plumbing through rated floor ceiling assemblies shall be provided with a UL listed fire sealant system. � ��� �� ����� Electrical Notes: ��'�^� °' � � 1. Provide all new electrical circuits,wiring,and fixtures to �� �..;� � ��•� ., ;�� comply with the requirements of the NEC. � �� � 'r�" ° °` 2. Provide rated enclosure around can lights to maintain rating of one-hour floor ceiling assemblies,or provide low voltage cans than have a ceiling penetration less than 16" sq. � �,� �� . .a. .�� �;..:�. ----�-.., WALL LEGEND: � � EXISTING WALLTO REMAIN NEW INTERIOR WALL "p"p NEW NON-RATED PARTITION.3 1/2" N AIl(1�S O N WD.STUDS@16"O.C.w/31/2"BATT � g�YANS � � INSUL.AND 5/8"GWB.EA.SIDE � _ _ _ � EXISTING WALLTO 8E DEMOUSHED � �,�3��2 �i�., Oct. 14, 2013;� DEMO PLAN � ��� � SCALE: 114" = 1'-0" 0 2, 4' g� ���� ���C`\ �;Ga;��: BUILDING PERMIT SCOTTHBRYANS LANDMARK CONDOMINIUMS �- SUBMITTAL ARCHITECT � (� (� � � � � scotl@shb-arch.com v �� 10-14-13 720-312•1187 INTERIOR REMODEL: UNIT 108 D � ( SHEET � �le OCT 16 2013 � 1 of 2 VAIL, COLORADO �� TOVVI� �:�� ��-���,_ � g�3- ��� 5 � .. .�.... ..�_., „.:_� _... _ I!' ���.��W ! e&f o.g� f���\. �° k''.:l•'i;q'' >'�!y'/'i''; �.. ��Qf. Y 15'-4" OPEN TO EXTERIOR STORAGE ABOVE CLOSET. REVERSE SWING OF EXISTING DOOR. STORAGE 2x6 EXTERIOR WALL w/R-19 EXISITING ENTRY BATT INSULATION AND DOOR TO REMAIN 5/8"GYP. BOARD EACH SIDE NEW STONE TILE � `F,m , \� AT ENTRYWAY = CUSTOM BUILT-IN v WD. BENCH z W N . m rn � � BED ROOM#1 H LL CARPET TI E CUSTOM BUILT-IN WD.CUBBIES CUBBIES � CV 3'-0"FIN. MIN. NEW PLUMBING 4-Ox6-8 � FIXTURES AND � CABINETRY CLOSET "' BUNK BEDS � NEW SHOWER CARPET '� WITH TILE FLOOR �, � AND TEMP.GLASS X ° ��5�'�/�� !�f1�� f"C��-°,r. ENCLOSURE �E � r.� 3'-0"FIN. MI . 00 l< —� —r� a C� OWNER'S _ ��� � O O `x° CLOSET `� �' -� _ � N CARPET � NEW 2x4 WALL `� O � (TYP.) (V � KI CE N NEW KITCHEN APPLIANCES M AND CABINETS. UPDATE ELEC. LAYOUTAS REQUIRED FOR � NEW LAYOUTAND CURRENT = I Ma I OO ELEC. CODE REQUIREMENTS - N NEW KITCHEN ISLAND `� _ — — — — — — — w/GRANITE TOP. RAISED BARAREA M 3'-6"H X 1'-0"W ON 2X4 PONY WALL. co S'-5" ' � , .. �:i� _ :���� ��a� �� � ��F�' � LIVING ROOM �� �Y � CARPET � ' - ' . � . . .'�'�;,. . � O EXISTING BALCONY WALL LEGEND: � EXISTING WALLTO REMAIN S'� FLOORAREA=613 SF NEW INTERIOR WALL NpARRiSON � NEW NON-RATED PARTITION.3 1/2" {�RYtf NS WD.STUDS@16"O.C.w/31/2"BATT A ' ������ INSUL.AND 5/8"GWB.EA.SIDE I,� C _ _ _ � EXISTING WALLTO BE DEMOLISHED `�,/� Oct. 14, 2013,;j �� FLOOR PLAN �1 � 2 SCALE: 114" = 1'-0" 0 2' 4' 8' ��+.�'�"��j'C`\� � ��a�,.:�:: SCOTT H BRYANS BUILDING PERMIT ARCHITECT �ANDMARK CONDOMINIUMS SUBMITTAL swtt(�shb-arch.com 10-14-13 720-312-1187 INTERIOR REMODEL: UNIT 108 SHEET VAIL, COLORADO 2 Of 2 NOTE: TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES .� 7C?�AI Of VAIL'• Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B13-0475 Project #: PRJ13-0623 Job Address: 610 W LIONSHEAD CIR VAIL Applied.....: 10/16/2013 Location......: Landmark Unit#108 Issued. . . : 11/07/2013 Parcel No....: 210106330008 OWNER PILA INTER, S.A. 10/16/2013 5150 HIDALGO 802 HOUSTON, TX 77056 CONTRACTOR BEACH MOUNTAIN BUILDERS, INC 10/16/2013 Phone: 970-390-2037 PATRICK RYAN PO BOX 749 EDWARDS CO 81632 License: C000003846 Description: Landmark Unit 108 New kitchen and cabinets, new applicances, new tub, tile and toilet. remove existing non-bearing walls and install bunk beds. New carpet and tile. Paint and retexture walls. Installing new electrical panel. Occupancy: R-2 Type Construction: IIIA Valuation: $40,000.00 ..................................�............,....,....,........._.......,...,. FEE SUMMARY .........,x,...................�,,.,.....».,,,,,....,...,..,.....,,.,...x...=.... Building Permit-----------> $542.75 Bldg Plan Check----------> $352.79 Use Tax Fee-----------------------> $600.00 Electrical Permit---------> $115.00 Elec Plan Check-----------> $74.75 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $0.00 Mech Plan Check---------> $0.00 Additional Fees--------------------> $0.00 Plumbing Permit--------> $120.00 Plmb Plan Check---------> $30.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $15.00 TOTAL PERMIT FEES--------------> $1,850.29 Payments-------------------------------> $1,850.29 BALANCE DUE------------------------> $0.00 ..,........�..................�.....................�........,........�...........,,........,,._......._,........,.�....................�......................__,......._............... DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4:00 PM. combination permit_012811 i z� . # � ���� r� a ..................................................................................................................................................................................... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: 613-0475 Address: 610 W LIONSHEAD CIR VAIL Owner: PILA INTER, S.A. Location: Landmark Unit#108 ......................................................x..�,,....,,....,,.....,...,...,,,.....,..........,...,.,......,....,,..,..,..........,........,..........,.,...............,.. combination permit_012811 a # ������, a ***rt**�t**�t***�t�t*�k*****�trt**************************************W*Ie********Yt*MMr*******Yt***�k*ik*ik*****�t**********************�t****************fe***ik****** REQUIRED INSPECTIONS AND STATUSES Permit#: B13-0475 Address: 610 W LIONSHEAD CIR VAIL Owner: PILA INTER, S.A. Location: Landmark Unit#108 *,�*****************�******«********,*******,,,.�*******************.,**„***,�******.****,�***************,.«*«„*******�****«««.,.,******,.****,.*****,.***«*«** Item: 00120 ELEC-Rough Item: 00220 PLMB-Rough/D.W.V. Item: 00230 PLMB-Rough/Water Item: 00030 BLDG-Framing Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail Item: 00190 ELEC-Final Item: 00290 PLMB-Final Item: 00090 BLDG-Final combination permit_012811 ****************************************+**************************�************************ TOWN OF VAIL, COLORADO Statement ******************************************�************�**************+********************* Statement Number: R130001921 Amount: $1, 392.75 11/07/201302:56 PM Payment Method: Check Init: CG Notation: ck 9470 beach mountain builders inc ----------------------------------------------------------------------------- Permit No: B13-0475 Type: COMBINATION BLDG PERMIT Parcel No: 2101-063-3000-8 Site Address: 610 W LIONSHEAD CIR VAIL Location: Landmark Unit #108 Total Fees: $1, 850.29 This Payment: $1, 392.75 Total ALL Pmts: $1, 850.29 Balance: $0.00 *****************************************************+************************+************* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 542.75 EP 00100003111100 ELECTRICAL PERMIT FEES 115.00 PP 00100003111100 PLUMBING PERMIT FEES 120.00 UT 11000003106000 USE TAX 40 600.00 WC 00100003112800 WILL CALL INSPECTION FEE 15.00 ----------------------------------------------------------------------------- � Department of Community Development ' 75 South Frontage Road TOWN OF VAIL � "'� va�i, co s�ss� � Tel: 970-479-2128 www.vaiigov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: Project#: ���--� �� ��v� ?j (�JO W, �. ion�s � aq�� Gt�fz I � 8 DRB#: (Nuonber) (Street) (Suite#) n (3`���� Building/Complex Name: �RI'1� rn Y�� � Building Permit#: �b Contractor Information Lot#: Block# Subdivision: Business Name: �3e�G+� ' �'roUev �N �J�� (L�/L �) q Work Class: New( ) Addition ( ) Alteration (��y Business Address: �3 OX � -7 J � ` City p�c �rJ�2� �j State: � Z�p: 8�6�3a Type of Building: ,,�1 ;� Single-Family( ) Duplex( ) Multi-Family Contact Name: __�rrT �['1! �Il� Commercial ( ) Other( ) Contact Phone: 3 9 O �" � O �7 Contact E-Mail: l3 G� /�'l '�'T1 � �ryl,(,f�s'/'• /�,�Work Type: Interior� Exterior( ) Both ( ) ( \ I hereby acknowledge that I have read this application,filled out Valuation of in full the information required,completed an accurate plot plan, Work Included Plans Included Work and state that all the information as required is correct. I agree to -- - - ci �� comply with the information and plot plan, to comply with all Town Elecfrical "�Yes ONo OYes ONo ordinances and state laws, and to build this structure according to Mechanical ( )Yes (�No ( )Yes ( )No �� the town's zoning and subdivision codes, design review ap- proved, International Buitding and Residential Codes and other Plumbing �)Yes ( )No ( )Yes ( )No �Od (7 ordinances of the Town applicable thereto. Building (�Yes ( )No ( )Yes ( )No a� 3 ��� � �'� t'�C7�(7 ; x Value of all work being performed: $ i Own r/Owner's Representative Si ature(Required) (value based on IBC Section 109.3 8 IRC Section 108.3� ! Electrical Square Footage (� ) 3 1 Detailed Scope and Location�of Work: Iy�W �1C r-�-�v Applicant Information � ��,� C. Applicant Name: � �J� -•.1,I�J �f�'{Z, 5 � � ' (�F}.'�-� LA.J i ('V (��-.i • �'�J 2 W � ` 9']�l✓ � Ari� (b.�i � Applicant Phone: �J' ��� ` a 3 9 " � 6 5' � 1�e w -r-u � , --�-�,, ) e-}- ° -�- i � � . Applicant E-Mail: �W � � � � U 11� I'1'� • (��—� LJ j?e o�� ��C 1 rrv i W S s-� rv d,rv - �e�QZ r Project Information�t,, ,�l w A � ( .� � (VV S�J�"�� J J rV�G Je�S • Owner Name:_ 1�6 � ��, (/l�4 �� 1 f�►yl ,j C7!V �l�P,v�J G�1'�-�-�' -` -�i 1� • �(�' ,2�Q,X�(�2 Parce�#: 0'2• � O � 6 �v 3 � � � O � �� � � n � (For Parcel#,contact Eagle County Assessors Office at(970-328-8640 or visit � � �/ � � www.eaglecounty.us/patie) ��n (use additional sheet if necessary) � ��Tm' �w°, �c� � For Office�Use Only: e�eC�A��,�- � ��I�N �i� �'f���, ��- Date Received Fee Paid: �y.- �,_ ._ � - Received From: ! �� , ��� ,�' � 6 �, i: �� �, ,�, I� Cash Check# '!i.v�i CC: Visa/ MC Last 4 CC # exp date: ��,; QC� � 6 20�3 � Auth # �:�� ji , i�� ;; � I V Y y 1 V �� �A��w 2013-Feb 01 I ! . � +����'l� � C�C�G;i���!i" C�� �' . ,� D ��,� OCT 16 2013 Project:Landmark CondominiumsLocation: Unit 108 �� �,{�� � a,�.� a � . r . ��:y 5 �-` 4��� , , �„� > ..���_...__ _ ._..,._.. Main Breaker Size: 2 0 0 amp s Existing Loads ` 0��� 613 Sq.Ft.X 3 watts per sq. ft............................ 18 3 9 watts �'3 1 Appliance cir.@1500 watts each.................... 15 0 0 watts N/A Laundry cir.@ 1500 watts each...................... watts � Range @ 8 kw................................................. 8 0 0 0 watts � Dishwasher and disposal @ 1500 watts each...... 3 0 0 0 watts � Microwave @ 2000 watts............................. 2 0 0 0 �,atts N/A Water heater @ 4.5 kw................................ watts N/A Tankless water heater.................................. watts N/A Dryer @ 5 kw........................................... watts � Refrigerator @ 1500 watts ........................ 15 0 0 watts 1 Other Sauna ,,,,,,,,,,,,,,, 9600 watts 1 Other Wall Heater ................. 1500 watts Other ................ watts Sub total 2 8, 9 3 9 Watts New Loads Poolpump............................................... watts Poollight................................................. watts Heatpump............................................... watts Chlorine generator...................................... watts Air blower................................................ watts Boatlift.................................................... watts 1 Other S auna ................ -9 6 0 0 watts 1 Other Lights ................ 420 watts Other ................ watts Total 19.�5 9 Watts First 10 kw @ 100%............................................. 10, 0 0 0 watts Remainder @ 40%.........9�.�.5.9............................ 3, 9 0 4 watts A/C heat @ 100%.................................................... watts Total watts 13, 9 0 4 Divided by 240 volts= 5 8 Amps *****************************+**************�****�**************�*************�***++******** TOWN OF VAIL, COLORADO Statement ***********+***********�******++�**+*******�*******************�**************************** Statement Number: R130001733 Amount: $457.54 10/16/201303:50 PM Payment Method: Check Init: CG Notation: ck 9443 beach mountain builders inc ----------------------------------------------------------------------------- Permit No: B13-0475 Type: COMBINATION BLDG PERMIT Parcel No: 2101-063-3000-8 Site Address: 610 W LIONSHEAD CIR VAIL Location: Landmark Unit #108 Total Fees: $1, 850.29 This Payment: $457.54 Total ALL Pmts: $457 .54 Balance: $1, 392.75 *************************************************************+****+************************* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 457 .54 ----------------------------------------------------------------------------- ►- 13 - ��f '75 LANDMARK CONDOS UNIT 108 Demand Load Calculations (Per NEC Article 220 Parts I-III) uantit Volt-Amps De= Total A General Dwelling unit Square footage 613 General& Lighting (1st 3 KVA) 613 SF X 3 X 100% - 1839 General & Lighting (Remainder) SF X 3 X 350�0 _ � Kitchen - Small Appliances 2 EA X 1500 X 35% - 1050 Refrigerator 1 EA X 1000 X 75% - 750 Dishwasher 1 EA X 1200 X 75% - 900 Oven/Range (Re:table220.19) 1 EA X 8000 X 80% - 6400 Disposal 1 EA X 1000 X 75% - 750 Microwave 1 EA X 2000 X 75% - 1500 Laundrv 8� Spa Aqaliances - No Laundry or Spa Mechanical Eauipment Wall Heater 1 EA X 420 X 100% = 420 TOTAL 13609 For 208V, 1-Phase, 3 Wire Service 13609 (VA) / 208 = 65 AMPS Existing 200 amp 1P service to remain ��i7Rn�c„irt7�l�r. ,��i t i f1 C -�� �1. -�r��"� H�� '`��_ ��� Arclutectur��l Engineering C'onsult�lnts �-' - blech�liic;�l,Electrirol��: Lirlitiur Uesi �i Ser�-ices ' a rna g ���``S� � ,• Au office «•ith LEED Acci�dited Prc�fessiou�ls ,��� �y�,� F'(_>Bo�8-��s9. =�0801 i7S H�;��-(y�� ?4. Ste 21�.A�-ou. (��lor:id�,.b�l(�ZQ �r� � '�.N ��� ,.,c�,, � �c , �� ,; Telzl�hoii�: 970-7-��i-85?0 Fas: 97()-748-8�?1 4,•,•'"„"„iA'�. ��zv��-.;�e�:•-t��il.coui Inspection Items for B13-0475 09:00 12/10/2014 Sec Item Id Description _____ A r Re Items Action Inheritable ` 120 ELEC-Rou h Yes R 1 AP No " 220 PLMB-Rou h/D.W.V. Yes R 1 AP No * 230 PLMB-Rough/Water Yes R 1 AP No * 30 BLDG-Framin Yes R 1 AP No " 50 BLDG-Insulation Yes R 1 AP No " 60 BLDG-Sheetrock Nail Yes R 1 AP No 190 ELEGFinal Yes R 1 AP No 290 PLMB-Final Yes R 1 AP No 90 BLDG-Final Yes R 2 AP No Total Rows:9 Page 1