HomeMy WebLinkAboutB13-0447 plans APPROVED Q,00 40 t) NIT 353 LC) DCIE AkPJkRTIVIENT C C) NDC) S o �y U_ _ � ° o 174 GORE CREEK DRIVE VAIL, MATERIAL SYMBOLS: ABBREVIATIONS: GENERAL NOTES: DRAWING INDEX: ARCHITECTURAL III III EARTH PLYWOOD ABV ABOVE L LENGTH AO.O COVER SHEET U r A1 .1 EXISTING MAIN LEVEL PLAN Ol DO NOT SCALE DRAWINGS o Q AFF ABOVE FINISHED FLOOR LDT LIGHT AND DRAPERY TROUGH AP ACCESS PANEL LT LIGHT TROUGH AC ACOUSTICAL LTL LINTEL 02 VERIFY ALL DIMENSIONS, CONDITIONS AND UTILITY LOCATIONS ON A1 .2 EXISTING UPPER LEVEL PLAN 0 o POROUS FILL/DRAINAGE FINISH WOOD ADD ADDENDUM LVR LOUVER THE JOB SITE PRIOR TO BEGINNING ANY WORK OR ORDERING ADD ADJACENT MH MANHOLE ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR A1 .4 UPPER LEVEL DEMOLITION PLAN ALT ALTERNATE MFR MANUFACTURE (ER) DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. A2.2 PROPOSED UPPER LEVEL PLAN WOOD-ROUGH ALUM ALUMINUM MO MASONRY OPENING U STONE MASONRY ARCH ARCHITECT (URAL) MTL METAL 03 AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY BSMT BASEMENT MAX MAXIMUM RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECT BEFORE BRG BEARING MECH MECHANIC (AL) CONSTRUCTION CONTINUES IN THOSE AREAS. BVL BEVELED MC MEDICINE CABINET STRUCTURAL CONCRETE BLOCKING 04 PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE, -� BIT BITUMINUOUS MEM MEMBRANE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE R" BLK BLOCK M METER (S) TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BLKG BLOCKING MM MILLIMETER (S) BEAMS UNLESS OTHERWISE NOTED. CONCRETE MASONRY UNIT GYPSUM BOARD BOT BOTTOM MIN MINIMUM ° `- BLDG BUILDING MIR MIRROR w 05 PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. 0 CPT CARPET (ED) MISC MISCELLANEOUS LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL o Q CSMT CASEMENT MULL MULLION MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, (� BATT INSULATION C CAULK (ING) NAT NATURAL COUNTERTOPS, SHELVES AND CLOSET RODS. CLG CEILING NR NOISE REDUCTION CT CERAMIC TILE NOM NOMINAL 06 O DENOTES DOORS. REFER TO FLOOR PLANS FOR LOCATIONS. REFER CLR CLEAR NIC NOT IN CONTRACT TO DOOR SCHEDULE FOR DOOR TYPES. RIGID INSULATION COD CARBON MONOXIDE DETECTOR NITS NOT TO SCALE COL COLUMN OPG OPENING 07 O DENOTES WINDOWS. REFER TO WINDOWS AND FLOOR PLANS FOR CONIC CONCRETE OPP OPPOSITE LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. CMU CONCRETE MASONRY UNIT OPH OPPOSITE HAND STEEL/METAL AS NOTED CONST CONSTRUCTION OH OVERHEAD CONT CONTINUOUS PR PAIR 08 COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT CJT CONTROL JOINT PK PARKING WITHIN CEILING, FLOOR AND WALLS SPACES. VERIFY LOCATIONS WITH CPR COPPER PVMT PAVEMENT CARPET CUST CUSTOM PL PLASTIC LAMINATE ARCHITECT. DT DRAPERY TROUGH PT POINT DTL DETAIL PSF POUNDS PER SQUARE FOOT 09 IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY DIM DIMENSION PSI POUNDS PER SQUARE INCH THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECTS OF THIS DR DOOR PL PROPERTY LINE PROJECT,THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE DRW DRAWING QT QUARRY TILE ARCHITECT. DF DRINKING FOUNTAIN REF REFERENCE 1 1 ELEC ELECTRIC (AL) REF REFRIGERATOR EL ELEVATION (S) REIN REINFORCE (D) (ING) 10 THE CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL , A4.00 A4.00 APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED ELEV ELEVATOR REQ REQUIRED EQ EQUAL RES RESILIENT APPROVALS.THIS PROJECT IS GOVERNED BY THE INTERNATIONAL UJ EXH EXHAUST REV REVISION (D), (ING) BUILDING CODE, 2009 EDITION. CODE COMPLIANCE IS BUILDING SECTION REFERENCE ELEVATION REFERENCE EXTG EXISTING REV REVERSE MANDATORY.THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT EXT EXTERIOR RH RIGHT HAND WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES FOC FACE OF CONCRETE R RISER INCLUDING IBC AND ALL LOCAL AND REGIONAL CODES. FOF FACE OF FINISH R&S ROD AND SHELF M — FOM FACE OF MASONRY RD ROOF DRAIN 11 THE CONTRACTOR SHALL FIELD COORDINATE AND OBTAIN N FOS FACE OF STUDS RDT RECESSED DRAPERY TRACK APPROVAL FROM THE ARCHITECT & ENGINEER BEFORE ANY M 1 1 1 FIN FINISH (ED) RFG ROOFING CUTTING, NOTCHING OR DRILLING OF ANY CAST-IN-PLACE 0 A4.00 A4.00 FFE FINISHED FLOOR ELEVATION RM ROOM CONCRETE, STEEL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS Z c FE FIRE EXTINGUISHER RO ROUGH OPENING WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING. a Q FDC FIRE DEPARTMENT CONNECTION R/S ROUGH SAWN ti IC DETAIL REFERENCE DETAIL REFERENCE FHC FIRE HOSE CONNECTION S SEALANT (EXTERIOR) FEC FIRE EXTINGUISHER CABINET SHTG SHEATHING H 0 FP FIREPLACE SHH SHOWER HEAD 12 THE CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND STAKE F 0 MAIN 1 FPS FIREPROOFING,SPRAYED SHC SHOWER CONTROLS OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT z OL FLG FLASHING SM SHEET METAL APPROVAL PRIOR TO BEGINNING ANY SITE WORK. J 100'-0" M.00 n FLR FLOOR (ING) SIM SIMILAR a FD FLOOR DRAIN SC SOLID CORE 13 IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE Q HEIGHT REFERENCE FTG FOOTING SPEC SPECIFICATON (S) CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, Z LLI SECTION REFERENCE FND FOUNDATION SQ SQUARE MATERIALS, TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC.TO OBTAIN FBO FURNISHED BY OTHERS STD STANDARD A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE v FPHB FREEZE PROOF HOSE BIB ST STAIN INDUSTRY. mi FUR FURRED (ING) STL STEEL ROOM NAME GA GAGE, GAUGE SD STORM DRAIN 14 ALL BUILDINGS TO FIT WITHIN PROPERTY LINES WITHOUT CROSSING D GALV GALVANIZED STIR STRUCTURAL EASEMENTS OR SETBACKS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. INS Q GC GENERAL CONTRACT (OR) TEL TELEPHONE GL GLASS, GLAZING TV TELEVISION REVISION REFERENCE ROOM NAME GYP GYPSUM BOARD THR THRESHOLD 15 PROVIDE ACCESS PANEL TO MOTOR FOR ALL WHIRLPOOL-TYPE TUBS. HB HOSE BIB T&G TONGUE AND GROOVE COORDINATE ACCESS LOCATIONS WITH INTERIOR DESIGNER AND HDW HARDWARE TOS TOP OF SLAB ARCHITECT TO PROVIDE INCONSPICUOUS LOCATION. HDR HEADER TOS TOP OF STEEL HTG HEATING TOW TOP OF WALL GRID W11 HVAC HEATING/VENTILATING/AC TB TOWEL BAR HT HEIGHT TR TRANSOM HC HOLLOW CORE T TREAD GORE CREEK oRi°` xo"; GRID BUBBLE WALL TYPE REFERENCE HM HOLLOW METAL TYP TYPICAL PROJECT SUMMARY: HOR HORIZONTAL LINO UNLESS NOTED OTHERWISE m Code: HWH HOT WATER HEATER VB VAPOR BARRIER N y45 1 INCL INCLUDE (D), (ING) VIF VERIFY IN FIELD _� � International Building Code 2012 Occupancy: R-2 ID INSIDE DIAMETER VERT VERTICAL o,t'� I 2 IBC INSTALLED BY CONTRACTOR VCT VINYL COMPOSITION GENERAL LOCATION OF '` ' Construction Type: TYPE en 4 A8.1 11 IBO INSTALLED BY OWNER WC WATER CLOSET UNITS 347 AND 353 ON GE APARTMENT I Use: Residential Condo INS INSULATE (D), (ION) WP WATER PROOFING THIRD FLOOR OF BUILDING lOD OMINIUM 3 INT INTERIOR WWF WELDED WIRE FABRIC COND Fire Suppression: ___, Existing Intelligent Addressable Fire Alarm JC JANITOR'S CLOSET W WIDTH, WIDE Existing Fire Sprinkler System INTERIOR ELEVATION REFERENCE WINDOW TAG KIT KITCHEN WDW WINDOW ISSUED FOR: DATE: LAM LAMINATE (D) WO WITHOUT N LAV LAVATORY WD WOOD 4 BUILDING PERMIT 9.26.13 PANNING 8 ENTRANCE,EASE LH LEFT HAND 33 STN— —TILE DOOR TAG MATERIAL BREAK y COPY RIGHT RESERVATION The drawings, specifications and other documents prepared by the Architect (Michael Suman Architect, LLC) for this project are instruments of the Architect's ZIONAI WINO' service for use solely with respect to this Project and, >�e--M(?IA4,4 4—) t TERNA unless otherwise provided in writing, the Architect shall be deemed the sole and exclusive author of these documents and shall retain,without limitation, all T se9°ado° s°o cep 1r sw a,cda,dmek 5-c �s...,.,.<.�4 -- .... -• common law, statutory and other reversed rights, including the copyright hereof. No person,whether 2013 MICHAEL SUMAN ARCHITECT,LLC.© ALL RIGHTS RESERVED. LODGE AT VAI L SITE PLAN having come rightly into possession hereof or otherwise, shall employ these documents on any other project, nor SCALE: for additions to this Project nor for the completion of this DRAWN: MDS Project by others, unless with the prior express written consent of the Architect and upon appropriate compensation to the Architect in an amount and kind PROJECT#: 1310 OWNER: CONTRACTOR: ARCHITECT: STRUCTURAL ENGINEER: MECHANICAL ENGINEER: ELECTRICAL ENGINEER: cllaismsalll proprietary rightsin the maelialwhicphisissued SHEET TITLE: COVER SHEET DAVID AND MONTANA BRANTLEY SRE BUILDERS, INC. SUMAN ARCHITECTS T. BOYLE ENGINEERING, INC. RADER INC. ARCHITECTURAL ENGINEERING in confidence for design and/or construction purposes of P.O. Box 6376 P.O. Box 7760 970.476.2170 40690 HIGHWAY 6, SUITE E1 DESIGN GROUP, INC. this Project as noted. These materials may not be Vail, CO 81658 AVON, COLORADO 81620 CONTACT:TIM BOYLE PO BOX 8610 1900 WAZEE STREET,SUITE 255 copied, modified, nor employed in any way without the 970.845.6359 970.479.7502 EMAIL: boyleeng @gwestoffice.net AVON, COLORADO 81620 DENVER, COLORADO 80202 specific prior written consent and permission of the CONTACT: MICHAEL SUMAN P:970.845.7910 P: 303.296.3034 Architect. CONTACT: STEVE ELICKER EMAIL: michael@sumanarchitects.com F: 970.845.7522 F: 303.296.3035 ■ EMAIL: sieve @srebuilders.com ©2013 Michael Suman Architect, LLC. All rights reserved. Pvo J-0 ri r N n U R L 6+ � C1 y 0 E CU I � � d7 W W U BALCONY TWO BALCONY Fl 08 ONE 107 Ip -iH[ll 777 Ill I WP2 TA I I CIAR SHWR z ' W BUMPOUT I I %46 n ' I I +80 E:l = BATH DINING 1 I I -- o O ONE ' - Fl-04-1 < 1 102 I Im ' DW KITCHEN 1 I Fl-03-1 O ' LIVING I I I , + , LIVING ROOM 2 i I ROOM 1 MAIN LEVEL cn I I - I 106 FFE:100'-01/2" ch I _ � ® UNIT 347 W J F-I ENTRY 1 M I wp1 UP LO ET REF 101 ' Z O L Q Lu °a SOFFIT LINE MAIN LEVEL BATH WAD 0 FFE:100'-01/2" TWO 71.5"AFF M J 114 LAUNDRY H UNIT 353 115 ENTRY 2 wp2 Z J DINING 2 i �i o CLOSET uP 113 BEDROOM 0 Q 110 Ili o m 0 112 CLOS. ONE > o 116 Z uj I , I G C I I y— KITCHEN 2 y o 111 REF I I < FEE m ' WP2 ISSUED FOR: DATE: BUILDING PERMIT 9.26.13 EXISTING MAIN LEVEL PLAN �-lSCALE: 1/4" = V-o° UNIT # 347 & UNIT #353 EXISTING 1 HR RATED SEPARATION WALLS TO BE MAINTAINED 0 2013 MICHAEL SUMAN ARCHITECT,LLC. ALL RIGHTS RESERVED. EXISTING 1 HR RATED SEPARATION WALLS TO BE ELIMINATED SCALE: 1/4"=1'-0" DRAWN: MDS PROJECT A' 1310 SHEET TITLE: EXISTING PLANS A Is I Pvo J-0 ri r N n U R L 6+ � C1 y 0 U E z Cll d C3 ,a d7 W U N =_ { 0 WP2 BATH / THREE UA / BEDROOM 205 THREE BEDROOM / 206 O TWO / 1 203 LIVING \/ W ROOM 2 OPEN TO BELOW OPEN TO /� DORMER 109 HALLWAY ABOVE BELOW ABOVE DORMER CLOSET / LOS 215 / 202 ch / LIVING 204 ROOM 1 / 106 I CLOSET/ WP1 DN CLOS BALCONY 207 0 214 1 a Q HALLWAY J,UPPER LEVEL M J WP2 I MASTER 201 FFE:108'-s° BEDROOM H O BEDROOM DN FOUR ~ v 208 212 Z J I a -- I O > wP2 Z n w I O DORMER 0 W c I BEDROOM ABOVE v mj Z I DORMER FIVE DORMER BATH M2 I ABOVE LOS 2-1 0-1 ABOVE FOUR -- I � — F 211 213 I � I � O MASTER j BATH WP2 ISSUED FOR: DATE: BUILDING PERMIT 9.26.13 EXISTING UPPER LEVEL PLAN �,2SCALE: 1/4° = V-o° UNIT # 347 & UNIT #353 EXISTING 1 HR RATED SEPARATION WALLS TO BE MAINTAINED 0 2013 MICHAEL SUMAN ARCHITECT,LLC. ALL RIGHTS RESERVED. EXISTING 1 HR RATED SEPARATION WALLS TO BE ELIMINATED SCALE: 114"=1'-O" DRAWN: MDS PROJECT A- 1310 SHEET TITLE: EXISTING PLANS A ls2 Pvo J-0 ri r N n U R L 6+ � C1 y 4) 0 U E z Cll d C3 ,a d7 W U N =_ { 0 WP2 ' BATH THREE BEDROOM 205 ' THREE F2-06-1 O BEDROOM O LIVING � TWO ROOM 2 ' F2-03--1 — — — 109 I CLOSET ' LOS 215 LIVING FF204 ' ROOM 1 106 wP1 HALLWAY 5 CLOS. � CLOSET 202 - 0 214 Z - - - - - - - - - - - - - - - - - - - - - - - - - - - a W °a --�I REMOVE EXISTING WALL 2'-6" 6" II FOR NEW DOORWAY UPP RLEVEL M J WP2 II - 1 HR RATING BETWEEN UNITS FFE:108'-8" HALLWAY H O MASTER II BEDROOM TO BE MAINTAINED 201 Z V 208 J --� o a Z0 II O BEDROOM p II FOUR V BATH 212 II LOS FOUR II I I --� 211 213 O O -- I I BEDROOM II FIVE II OMASTER 210 BATH -- 0 20s WP2 - - - DENOTES ITEMS TO BE REMOVED AND/OR REPLACED UPPER LEVEL DEMO PLAN A1.4 SCALE: 1/4° = V-o° UNIT # 347 & UNIT #353 ISSUED FOR: DATE: BUILDING PERMIT 9.26.13 - - EXISTING 1 HR RATED SEPARATION WALLS TO BE MAINTAINED 0 2013 MICHAEL SUMAN ARCHITECT,LLC. ALL RIGHTS RESERVED. MMllMllll M MlMlllllll EXISTING 1 HR RATED SEPARATION WALLS TO BE ELIMINATED SCALE: 114"=1'-0" DRAWN: MDS PROJECT A' 1310 SHEET TITLE: DEMO PLANS A ls4 Pvo J-0 u- CO3 E o � N Q+ U a sr Q1 u e E } L0 `o d} _ W U 7Ln y WP2 BATH \ \ / THREE \ 205 BEDROOM ' THREE BEDROOM LIVING � � OPEN TO 206 TWO ROOM 2 OPEN TO BELOW /\ 203 uj 109 A BELOW / \ CLOSET \ 215 \ / \ HALLWAY LOS \ / LIVING \ 202 204 \ ROOM 1 202 \ / 106 � � � \ V \ WP1 DN 26x 68 > CLOS \ 207 214 O cl ti -- (2) NEW DOORS BACK-TO-BACK- uPPERLEVEL - 1 HR RATING BETWEEN 2'-6" 6" 201 M FFE:108'-s° UNITS TO BE MAINTAINED HALLWAY 26 x 6$ / H O II J ---u O a z o O BEDROOM p MASTER FOUR V BEDROOM BATH 212 I 2os BEDROOM FOUR � LOS FIVE 213 210 O I O MASTER j BATH i WP2 PROPOSED UPPER LEVEL PLAN �.2SCALE: 1/4" = V-o° UNIT # 347 & UNIT #353 ISSUED FOR: DATE: BUILDING PERMIT 9.26.13 PARTITION LEGEND: DOOR SCHEDULE - BRANTLEY RESIDENCE 9.25.13 o' NEW WALL CONSTRUCTION DOOR ROOM TYPE SIZE HINGE TEMP MATERIAL GLASS NOTES NO NAME (VIEW FROM OUT) U_VALUE EXISTING WALL CONSTRUCTION 101 FfALL4VAY A-HINGED 26x68 R NO WOOD SOLID,1/2 HR RATED,PA INT TO MATCH WA LL HALLWA)' A-HINGED 26x68 L NO WOOD SOLID,1/2 HR RATED,PA INT TO MATCH WALL NEW STONE VENEER TO REPLACE EXISTING PE Oc2013 MICHAEL SUMAN ARCHITECT,LLC. ALL RIGHTS RESERVED. SCALE: 114"=1'-0" DRAWN: MDS PROJECT A- 1310 SHEET TITLE: PROPOSED PLANS A2s2