Loading...
HomeMy WebLinkAboutDRB130422 PLANS APPROVEDCROSS RENOVATION - DRB SUBMITTAL REVISIONS 126 FOREST RD. #W VAIL, CO 81651 GENERAL NOTES: I. DO NOT SCALE DRAWINGS. 2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. 3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR AREAS. 4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS OTHERWISE NOTED. S. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS. 6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR TYPES. 7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. 8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS. 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY IN THE PROJECT. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL RESIDENTIAL CODE. COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN IBC AND ALL LOCAL AND REGIONAL CODES. 1 I. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND OBTAIN APPROVALS FROM THE ARCHITECT /ENGINEER BEFORE ANY CUTTING, NOTCHING, OR DRILLING OF ANY CAST -IN -PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION. 12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. 13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF & DECK SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL PROBLEMS WITH THESE SURFACES. 14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN APPROVAL. I S. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. 16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND /OR OUTSIDE SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS TO THE SITE. 18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE- VEGETATED TO BLEND WITH THE NON - DISTURBED LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE- VEGETATED TO BLEND WITH THE NON - DISTURBED LANDSCAPE. 19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER. 20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT. PROI ECT SUMMARY: Code: INTERNATIONAL RESIDENTIAL CODE 2012 Zoning: SINGLE- FAMILY RESIDENCE Occupancy Classification: TYPE R DIV. 3 Construction Type: TYPE V A monitored fire alarm system is required and must comply with NFPA 72(2002) and VFES standards PROD ECT TEAM: ARCHITECT: K.H. WEBB ARCHITECTS P.C. 710 W. LIONSHEAD CIRCLE, UNIT A VAIL, CO 81657 PH. 970.477.2990 CONTACTS: KYLE H. WEBB JONIQUE JANDA OWNER CONTACT: RON BYRNE PH. 970.476.1987 SYMBOLS: ,44.00 Section Cut Reference A3.0 Elevation Reference 4 )ro Detail Cut Reference Revision Cloud 0 Grid Bubble A4.1A Detail Area Reference EL 0' -0° Elevation Symbol Large Area Detail Reference Q1 12/31/1999 Revision Symbol O Material Tag DRAWING INDEX CIVIL 1:10 ARCHITECTURAL A 001 1/8" = I'0" A 100 1/811 = 1'0" A 1 0 1 1/411 = 110" A 102 1/411 = 110" A 103 1/4" = I'0" A 104 1/411 = I'0" A 105 1/4" = I'o" A 106 1/4" = 110" A 200 1/4" = 1'0" A 201 1/4" = 1'0" A 202 1/4" = 1'0" A 203 1/4" = 1'0" SUPPLEMENT SURVEY GRFA CALCULATIONS SITE PLAN - PROPOSED GARAGE LEVEL PLAN - EXISTING /PROPOSED NEW BEDROOM LEVEL PLAN - EXISTING /PROPOSED MASTER LEVEL PLAN - EXISTING /PROPOSED LIVING LEVEL PLAN - EXISTING /PROPOSED LOFT PLAN - EXISTING /PROPOSED ROOF PLAN - EXISTING /PROPOSED WEST ELEVATION - EXISTING /PROPOSED NORTH ELEVATION - EXISTING NORTH ELEVATION - PROPOSED SOUTHWEST ELEVATION - EXISTING /PROPOSED READ RESIDENCE SET DRB130422 approved per the DRB on 10/16/2013 Design Review Staff Approval TOWN By Joe Batcheller at 4:29 pm, Oct 18, 2013 RECEIVED By David Rhoades at 12:37 pm, Sep 19, 2013 i 0 a ri O O� O 0 Q 0 J 0 V J Q Q Z W J V V 0 Q W Z 0 J W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V V Z . W v O V i 0 a ri O O� O 0 Q 0 J 0 V J Q Q Z W J V V 0 Q W Z 0 J W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z . W O W Q V1 �o %,#on PSI O V PROJECT: CROSS DRAWN BY: JJ DATE: 09.09.13 REVISIONS: DRB SUBMITTAL REVISIONS 09.19.13 COVER z O U Z) z O U O LL O 77 L----------------- i LOT 7 41199 HIGHWAY 6 & 24, EAGLE —VAIL P.O. BOX 1230 EDWARDS, CO. 81632 (970)949 -1406 LOT 6 UT EASI I SEWER MANHOI FOUND PLAIN #5 REBAR Landscaping Required: 9,437 sf Landscaping Existing: 11,318 sf Landscaping Proposed: 11,141 sf SEWER MANHOLE (BASIS OF ELEVATION) INVERT EL= 8238.9' MEAS RIM EL= 8245.0' 45,0 O 3'X 3' STORM FOREST wv '_ GRATE EDGE OF In ROAD y� DENOTES DECIDUOUS TREE <0.5' TRUNK DIAMETER DENOTES DECIDUOUS TREE 0.5' -1.0' TRUNK DIAMETER DENOTES DECIDUOUS TREE >1.0' TRUNK DIAMETER DENOTES CONIFEROUS TREE <0.5' TRUNK DIAMETER DENOTES CONIFEROUS TREE 0.5-1.0' TRUNK DIAMETER DENOTES CONIFEROUS TREE >1.0' TRUNK DIAMETER 40.2 EBER & kP LS #16827 STONE ALK 3 NOTES: 1) DATE OF SURVEY: 8/20/13 2) SURVEYOR HAS MADE NO INVESTIGATION OR INDEPENDENT SEARCH FOR AMENDED PLATS, EASEMENTS OF RECORD (OTHER THAN PLATTED), ENCUMBRANCES, RESTRICTIVE COVENANTS, OWNERSHIP TITLE EVIDENCE, OR ANY OTHER FACTS THAT AN ACCURATE AND CURRENT TITLE SEARCH MAY DISCLOSE. 3) NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT, MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF THE CERTIFICATION SHOWN HEREON. 4) BEARINGS AND DISTANCES ALONG PROPERTY LINES SHOWN HEREON ARE AS SHOWN ON THE SUBDIVISION PLAT ONLY. A BOUNDARY SURVEY WOULD BE NECESSARY TO DETERMINE THE TRUE DIMENSIONS OF THE LOT AND SETBACKS, WHICH MAY VARY FROM THE PLATTED DIMENSIONS. 5) THIS SURVEY AND THE INFORMATION CONTAINED HEREON IS THE PROPERTY OF EAGLE VALLEY SURVEYING, INC. AND IS INTENDED FOR THE SOLE USE OF THE ORIGINAL CLIENT ONLY. ANY USE OF OR TRANSFER TO OTHERS IS PROHIBITED. 6) BASIS OF ELEVATION: SEWER MH NORTH OF NORTHEAST CRN LOT 6. (SEE DRAWING). 7) ALL PEAK ELEVATONS ARE TO CEDAR SHINGLES. 8) POSTED ADDRESS: 126 FOREST ROAD 9) BUILDING SETBACK INFORMATION IS NOT PLATTED. PRIOR TO ANY DESIGN OR CONSTRUCTION IMPROVEMENTS ON THIS PROPERTY, TOWN OF VAIL SHOULD BE CONTACTED FOR CORRECT BUILDING SETBACK INFORMATION. 10) BUILDING SHOWN WAS LOCATED AND MEASURED TO TRIM AND VARIOUS EXTERIOR MATERIALS. STRUCTURE AND DIMENSIONS SHOWN SHOULD NOT BE RELIED UPON FOR ADDITION DESIGN. Wv GM i O LEGEND WATER VALVE SANITARY SEWER MANHOLE GAS METER STORM SEWER INLET CULVERT SPRINKLER VALVE BOULDER WALL CONCRETE WALL W/ STONE VENEER COLUMN W/ STONE VENEER - -- ROOF RIDGE /EAVE DECK OUTLINE BUILDING OVERHANG — — FLOWLINE DITCH /WATER FEATURE OUTLINE WATER FEATURE SURVEYOR'S CERTIFICATE I, Stan Hogfeldt, a Professional Land Surveyor registered under the laws of the State of Colorado, do hereby certify that this topographic survey was made by me and under my supervision, and that the survey is accurate and correct to the best of my knowledge. Stan Hogfeldt Colorado P.L.S. 26598 Date: GRFA CALCULATION: 3,915 ( SEE SF -1 READ RESIDENCE SET FOR PRIMARY EXHIBITS) -600 SEC. (40 %) PRIM.( 60 %) GARAGE LEVEL 839 1016 4.- NEW BEDROOV 792 � MASTER 984 812 o LIVING 982 1309 v LOFT 318 755 O NET SF 3,915 GARAGE CR.: -600 BSMNT DED.: -680 Z TOTAL GRFA: 2,635 sf 3,892 -600 -823 2,469 sf (5,104) Iscale 1/8 " =1' GARAGE LEVEL GRFA scale 1/4" =1' -0" LOFT GRFA scale 1/411= 11 -01' NEW BEDROOM GRFA scale 1/4" =1' -0" LIVING GRFA scale 1/4" =1' -0" MASTER GRFA scale 1/4" =1' -0" 0 o� a N N O N O� N �O D Q 0 J V J Q Q Z W J V V 0 Q W �n Z J VI W I� NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V V Z 4.- � W o v CC O 0 o� a N N O N O� N �O D Q 0 J V J Q Q Z W J V V 0 Q W �n Z J VI W I� NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z W � o W CC O Q V1 �o Loon N_ O CC V PROJECT: CROSS DRAWN BY: JJ DATE: 09.09.13 REVISIONS: DRB SUBMITTAL REVISIONS 09.19.13 GRFA EXHIBIT A001 z _O U z O U CC O LL O z 60,831no )joo�a �O 30d� !F- 10-1 r / \ -)k-ld M � I 3N0159d�� fv fv O O Design Review Staff Approval TO M OF VA L # By Joe Batcheller at 4:29 pm, Oct 18, 2013 (` L *-b9 M,6�.LLN O 3�OHNdW 2�3 M35 41M ON) b 10� (ld�d NO NOISN3W H1 Id I�Iln 1N3W3Sd3 1J 0 \ACCESSEASMENT RECORDED BOOK 70, PAGE 202 X. pa FOREST ROAD (50' R.O.W.) AM SITE PLAN -PROPOSED scale 1/8" =1' -0" % O J` CIO 0 o, o1 r 0 a 0 0 a 0 J O V J a z W J V V 0 Q W Z VI z O J V] W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W v V Z . V 0 O v V QC O 0 o, o1 r 0 a 0 0 a 0 J O V J a z W J V V 0 Q W Z VI z O J V] W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z . W 0 O Lon V QC O Q V1 �o Loon N_ O �C V PROJECT: CROSS DRAWN BY: JJ DATE: 09.09.13 REVISIONS: DRB SUBMITTAL REVISIONS 09.19.13 DRB REVISION REQUEST 09.2 7.13 SITE PLAN A100 z O U V) z O U O LL H O 77 m GARAGE LEVEL FLOOR PLAN - EXISTING scale 1/4" =1' -0" Design Review Staff Approval TOWN By Joe Batcheller at 4:29 pm, Oct 18, 2013 WALL TYPE KEY: EXISTING WALL ® ®��► 1 11 11 I' DEMOLISH GARAGE LEVEL FLOOR PLAN - PROPOSED scale 1/411=11-011 0 o� a N 0 a 0 0 Q 0 J O V J Q Q z W J V V 0 Q W �n Z O J VI W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W v V Z , W � W O v CC O 0 o� a N 0 a 0 0 Q 0 J O V J Q Q z W J V V 0 Q W �n Z O J VI W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z , W � O W CC O Q V1 �o Loon N_ O CC V PROJECT: CROSS DRAWN BY: JJ DATE: 09.09.13 REVISIONS: DRB SUBMITTAL REVISIONS 09.19.13 FLOOR PLAN A101 z _0 U z O U O LL I— O z Design Review Staff Approval ����� By Joe Batcheller at 4:29 pm, Oct 18, 2013 TOWN WALL TYPE KEY: EXISTING WALL T NEW WALL NEW BEDROOM LEVEL FLOOR PLAN - PROPOSED scale 1/4" =1' -0" 0 o� a N N O N O� N �O D Q 0 J V J Q Q Z W J V V 0 Q W �n Z J VI W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V V Z , 4.- � W O v CC O 0 o� a N N O N O� N �O D Q 0 J V J Q Q Z W J V V 0 Q W �n Z J VI W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z , W � O W CC O Q V1 �o Loon N_ O CC V PROJECT: CROSS DRAWN BY: JJ DATE: 09.09.13 REVISIONS: DRB SUBMITTAL REVISIONS 09.19.13 FLOOR PLAN A102 z _0 U z O O LL O z TOTAL EXISTING AREA: 814 SQ. FT. A201 / 1 A200 MASTER LEVEL FLOOR PLAN - EXISTING scale 1/4" =1' -0" Design Review Staff Approval TOWN ��� ! By Joe Batcheller at 4 :29 pm, Oct 18, 2013 KEY: EXISTING WALL 0 1XVITATi %1II DEMOLISH i MASTER LEVEL FLOOR PLAN - PROPOSED scale 1/4" =1' -0" 0 a o� r 0 o� v� �o 00 O D 0 J O V a Q z W J V V 0 Q W 2 z O J �n W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V V Z , W v � a� � O v QC O 0 a o� r 0 o� v� �o 00 O D 0 J O V a Q z W J V V 0 Q W 2 z O J �n W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z , W � � O QC O Q V) �o V) N_ O �C V PROJECT: CROSS DRAWN BY: JJ DATE: 09.09.13 REVISIONS: DRB SUBMITTAL REVISIONS 09.19.13 FLOOR PLAN A103 Z O H U Z) z O U O LL H O 77 TOTAL EXISTING AREA: 821 SQ. FT. MAIN LEVEL FLOOR PLAN - EXISTING scale 1/4" =1' -0" Design Review Staff Approval TOWN OF VAI By Joe Batcheller at 4:29 pm, Oct 18, 2013 � WALL ALL iH MAIN LEVEL FLOOR PLAN - PROPOSED scale 1/4" =1' -0" 0 a o� r 0 a 00 0 0 0 J O V J Q Z W J V V 0 Q W 2 Z O J �n W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W v V Z , W v � � O %.wow, c_n V v QC O 0 a o� r 0 a 00 0 0 0 J O V J Q Z W J V V 0 Q W 2 Z O J �n W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z , W � � O %.wow, c_n V QC O Q Loon �o V> nl O V PROJECT: CROSS DRAWN BY: JJ DATE: 09.09.13 REVISIONS: DRB SUBMITTAL REVISIONS 1 09.19.13 FLOOR PLAN A104 z _O U D z O U O ILL H O 77 TOTAL EXISTING AREA: 377 SQ. FT. 1 A201 2 A203 V TO BELOW 1 A200 LOFT LEVEL FLOOR PLAN - EXISTING scale 1/4" =1' -0" LI m mdul Design Review Staff Approval TOWN ,1 By Joe Batcheller at 4:30 pm, Oct 18, 2013 WALL TYPE KEY: LOFT LEVEL FLOOR PLAN - PROPOSED scale 1/411=11-011 0 Q 0 J O V W ~ Z 0 o� a v N Q W V � O J a 0 Q 0 J O V W ~ Z NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z W W CC Loon V1 O CC V 0 oc O W oc � O Q �o PROJECT: CROSS DRAWN BY: JJ DATE: 09.09.13 REVISIONS: DRB SUBMITTAL REVISIONS 1 09.19.13 FLOOR PLAN A105 z _0 U z O U O LL O z W_ V V v o Q W Z O J VI O n NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z W W CC Loon V1 O CC V 0 oc O W oc � O Q �o PROJECT: CROSS DRAWN BY: JJ DATE: 09.09.13 REVISIONS: DRB SUBMITTAL REVISIONS 1 09.19.13 FLOOR PLAN A105 z _0 U z O U O LL O z ROOF PLAN - EXISTING scale 1/4" =1' -0" Design Review Staff Approval By Joe BatcheHer at 4:30 pm, Oct 18, 2013 TOWN OF VAIL ROOF PLAN - PROPOSED scale 1/411=11-011 0 o� a N N O N O� N �O 0 0 Q 0 J V J Q Q I- Z W J V V 0 Q W �n Z J VI W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V V Z , W � W O v CC O 0 o� a N N O N O� N �O 0 0 Q 0 J V J Q Q I- Z W J V V 0 Q W �n Z J VI W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z , W � O W CC O Q V1 �o Loon N_ O CC V PROJECT: CROSS DRAWN BY: JJ DATE: 09.09.13 REVISIONS: DRB SUBMITTAL REVISIONS 09.19.13 ROOF PLAN A106 z _0 U z O U O LL O z FINISHES KEY M01 STONE TO MATCH EXISTING M02 VERTICAL SIDING TO MATCH EXISTING M 33 FASCIA TO MATCH EXISTING W MO v WINDOWS AND DOORS JELDWIN WINDOWS AND DOORS, CHESTNUT BRONZE M05 ROOF TO MATCH EXISTING MO GUTTER TO MATCH EXISTING GUTTER SYSTEM M 07 SNOW FENCE L82.4 SNOW FENCE BY ROCKY MOUNTAIN SNOW GUARDS INC. M08 RAILING TO MATCH EXISTING Fm-o-q RAILING NEW STEEL FRENCH BALCONY M1 GARAGE DOOR TO MATCH EXISTING M11 V1 �o M12 %,#on N_ M13 O M1 V Design Review Staff Approval 0 X VAIL ,& By Joe Batcheller at 4:30 pm, Oct 18, 2013 102' -0" WEST ELEVATION - EXISTING 1 WEST ELEVATION - PROPOSED 1/4" = 1' -0" O CN O� N n 0 a r- Ln 1�O O D O J O V a Q z W V V D Q W Lon 2 Z O J I- Ln W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W v V Z , W � v � a� O V J DC O O CN O� N n 0 a r- Ln 1�O O D O J O V a Q z W V V D Q W Lon 2 Z O J I- Ln W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z , W � � O W J DC O a V1 �o %,#on N_ O CC V PROJECT: DRAWN BY DATE: REVISIONS: CROSS JJ 09.09.13 DRB SUBMITTAL REVISIONS 109.19.13 ELEVATIONS A200 z 0 U z O U O LL_ H O z FINISHES KEY MO1 STONE TO MATCH EXISTING MO2 VERTICAL SIDING TO MATCH EXISTING M03 FASCIA TO MATCH EXISTING W MO v WINDOWS AND DOORS JELDWIN WINDOWS AND DOORS, CHESTNUT BRONZE M05 ROOF TO MATCH EXISTING M 0 GUTTER TO MATCH EXISTING GUTTER SYSTEM M07 SNOW FENCE TO MATCH EXISTING MO8 RAILING TO MATCH EXISTING M09 RAILING NEW STEEL FRENCH BALCONY M 10 GARAGE DOOR TO MATCH EXISTING M11 V1 �o M12 V1 N_ M13 O M1 CC V 0 o� a N n 0 r_ a 0 a 0 J O V Q Q z i W J V V 0 Q W z 0 J �n W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W v V Z W v � O v J DC O 0 o� a N n 0 r_ a 0 a 0 J O V Q Q z i W J V V 0 Q W z 0 J �n W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z W � O W J DC O a V1 �o V1 N_ O CC V PROJECT: DRAWN BY DATE: REVISIONS: CROSS JJ 09.09.13 DRB SUBMITTAL REVISIONS 09.19.13 ELEVATIONS A201 z O U z O U O LL I- O z FINISHES KEY M01 STONE TO MATCH EXISTING M 22 VERTICAL SIDING TO MATCH EXISTING M03 FASCIA TO MATCH EXISTING W MO v WINDOWS AND DOORS JELDWIN WINDOWS AND DOORS, CHESTNUT BRONZE M05 ROOF TO MATCH EXISTING M06 GUTTER TO MATCH EXISTING GUTTER SYSTEM M07 SNOW FENCE TO MATCH EXISTING Mpg RAILING TO MATCH EXISTING M09 RAILING NEW STEEL FRENCH BALCONY Fm-1 01 GARAGE DOOR TO MATCH EXISTING M11 %won N M12 O M13 DC M1 Design Review Staff Approval ���� t By Joe Batcheller at 4:30 pm, Oct 18, 2013 TOWN 1 WEST ELEVATION - PROPOSED ,/ = P -0" 0 oI C7.1 r_ 0 r- CPI 00 O O J 0 v J Q a z W J V V 0 a W S Z O J to W ►� NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W v V Z W � v 0 a� O j v~_, V v cc J DC O 0 oI C7.1 r_ 0 r- CPI 00 O O J 0 v J Q a z W J V V 0 a W S Z O J to W ►� NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z W � 0 O j v~_, V W cc J DC O Q V1 �o %won N O DC V PROJECT: DRAWN BY DATE: REVISIONS: CROSS JJ 09.09.13 DRB SUBMITTAL REVISIONS 09.19.13 ELEVATION A202 Z O U z O U O LL I-- O z 1VL -V SOUTHWEST ELEVATION - EXISTING 1/4" = 1' -0" FINISHES KEY M01 STONE TO MATCH EXISTING M02 VERTICAL SIDING TO MATCH EXISTING M03 FASCIA TO MATCH EXISTING MO WINDOWS AND DOORS JELDWIN WINDOWS AND DOORS, CHESTNUT BRONZE M05 ROOF TO MATCH EXISTING M 0 GUTTER TO MATCH EXISTING GUTTER SYSTEM M07 SNOW FENCE TO MATCH EXISTING MOB RAILING TO MATCH EXISTING Fm-o-q RAILING NEW IRON RAILING P-0 GARAGE DOOR TO MATCH EXISTING M11 M12 �o M13 N_ M1 CC -71 -V SOUTHWEST ELEVATION - PROPOSED 1/4" = l' -0" 0 o, o� rr r� 0 r_ a 6r1 �O co 0 0 Q 0 J 0 V J Q Q Z W J V cc V 0 Q W z 0 J Vl W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W v V Z , W v O %.00n Loon V v 9 J CC O 0 o, o� rr r� 0 r_ a 6r1 �O co 0 0 Q 0 J 0 V J Q Q Z W J V cc V 0 Q W z 0 J Vl W NOT VALID FOR BUILDING PERMIT WITHOUT ARCHITECT'S WET STAMP © KHWEBB ARCHITECTS, PC COPYRIGHT 2013 W V Z , W O %.00n Loon V W 9 J CC O Q V1 �o Vn N_ 0 CC V PROJECT: DRAWN BY DATE: REVISIONS: CROSS JJ 09.09.13 DRB SUBMITTAL REVISIONS 09.19.13 ELEVATION A203 z O U Ln z O U O LL I— O z