HomeMy WebLinkAboutB12-0596 REV1-ComCheck COMcheck Software Version 3.9.2
Interior Lighting Compliance
Certif�cate
2009 IECC
Section 1: Project Information
Project Type:Alteratton
Project 7itle:Lionsquare Lodge North Retai!TI
Construction Site: OwnerlAgent: DesignerlContractor:
Unit 120 Viefe and Company Lucas Edwards
Vail,CO AEC
PO Box 8489
Avon,CO 81620
(970)748-8520
lucas@aec-vail.com
Section 2: Inferior Lighting and Power Calculation
A B C D
Area Category Floor Area Allowed A1lowed Wafts
(ft2} Watks I ft2 {B x C)
Retail 645 1.5 968
Allowance:Vehides,sporting gaads,srr�all electronics highlighting 1 Fix.ID: 645(a) 4.fi 387[b}
Track lighting 1
Supplemental Allowed Watts(c)= 956
Total Allowed Watts= 23t0
(a)Area claimed may exceed total�laor area when Retai]Merchandise Highlighting allowance(s)are specified.
(b} Allowance is(B x C)or the actual watfage of the fixtures given in Section 2,whichever is Iess.
(c) Supplemental wa[fs must be associated wifh retail merchandise highfighting fixtures.
(e) Additional controlslswitching allowances are based on number of fi�eiures or wattage cantrolfeci,nat flaar area of allowan�e.
Section 3: Interior Lighting Fixture Schedule
A B C D E
Fixture ID:Description!Lamp!Wattage Per Lamp 1 Ballast Lamps! #nf Fixfure (C X D)
Fixture Fixtures WatL
Retal(545 sq:ft.)_�--- - .--. ._
...._ _._. .__._ _... . ...... ...... _ . __..._. _ _..._.._.. .._.� .. _.._.... __ ___ _ _ _
Compact Fluorescent 1:Triple 4-pin 32W.Electronic: '[ 18 32 57fi
Linear Fluorescent 1:48"T8 32W:Elecironic: 2 6 64 384
Track lighting �:Wattage based on low-voltage transformer capacity 0 0 0 '[350
Total Proposed Watts= 2310
Section 4: Requirements Checklis#
. . . . .. -
Lighting Wattage:
� 1. Tota1 proposed watts m�tst be Isss lhan or equal to iotaf allowed watts.
A[[owed Watts Proposed Watts Complies
2310 2310 Passes with merchandise highlighting allowance
Controls, Switching, and Wiring:
� 2. Dayiight zones under skylighis mare than 35 feeE from the perimeter have lighting controls separate from daylight zones adjacent to
vertical fenestration.
Projeci Title: Lionsquare Lodge �forth Retail TI Report date: 10118/13
Data filename; Untitled.cck Page 9 of 2
� 3. DaylighE zones have individual fighting controls independent from ihat of fhe general area lighting.
Excepfions:
� Coniiguous daylight zones spanning no more ihan lwo orientations are a[lowed to he controlled by a single controlling device.
p Daylight spaces enc[osed by walls or ceiling height partiGons and containing two or fewer fight fix�ures are not required to have a
separate switch for general area lighting.
� 4. ]ndependent controls for each space(switchloccapancy sensor).
Excepiions:
p Areas designated as security or emergency areas that must be conlinuously illuminated.
� Lighfing in sfairways or corridors that are elements of the means of egress.
� 5. Master switch ai entry to hotel/motel guest room.
0 6. Individual dwel[ing unils separaiely metered.
� 7. Medical task lighcing or art/history display lighting elaimed to be exempt from compliance has a conlrol device independent o4 the controi
of the nonexempt]ighting.
� 8. Each space required io have a manual oontrol also allows for reducing the connecEed lighting load by at leasE 50 percent by either
confrolling all luminaires,dual swifching of alternate rows of luminaires,altemate luminaires,or alfernate lamps,switching fhe middle
]amp luminaires independently of other lamps,or switching each luminaire or each lamp.
Exceptions:
� Only one luminaire in space.
0 An occupant-sensing device cantrols the area.
0 The area is a corridor,storeroom,restroom,pupGc lobby or sleeping unit.
❑ Areas t�at use less than 0.6 Wattslsq.ft.
� 9. Automafic lighting shutoff control in buildings farger than 5,000 sq.ft.
Exceptfons:
❑ Sleeping units,pafienY care areas;and spaces where auEomatic shutoff would endanger safety or security.
� 10.Photocelllastronomical time switch on exterior lights.
ExcepSons:
0 Lighling intended for 24 hour use,
� 11.Tandem wireci one-[amp and three-lamp ballasEed luminaires(No single-lamp ballasts).
Exceptions;
0 Electronic hign-frequency ballasts;Luminaires on emergency circuiis or with no a�ailable pair.
Section 5: Compliance 5tatement
Camplfance Statement: The proposed lighting alteratian�roject represented in this document is consistent with the building plans,
specifications and other calculaiions submitted with this permit application.The proposed lighting alteration projact has been designed ta meet
the 2009 IECC,Chapfer 8,requiremenfs in COMcheck Version 3.9.2 and to comply with the mandatory requirements in the l�equirements
Check[ist.
�Cd,L�t,S C. :vitr�5 '� � � r �� ( �l�
Name-Title ��ture Date
Project Titls: Lionsquare Lodge North Retail TI Repori date: 1Q11$I13
Data filename: llntitled.cck I'age 2 of 2