Loading...
HomeMy WebLinkAboutA13-0071 ' .���.�'�%% 'i i�.. .. ����;�. Fire and Emergency Services � ���" 2399 N . Frontage Road W. ,: �;� Vail , Colorado 81657 %h �� Tel : 970-479 -2252 �� �� � � �� � � � www. vailgov. com �ir� � ���r���+�+� �� r��a� �+�� Fire Marshall FIRE �4LARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of thi � form . Application will not be accepted without this information . Project Street Address: Office Use : 356 E Hanson Ranch Road Number Project #: ( ) (Street) (Suite #) Building/(;omplex Name: Christiana At Vail Building Permit #: Alarrn Permit #: Contractor Information : Lot #�: Block # Subdivision : Company: Superior Alarm & Electronics Company Address : PO BOX 49 � O Detailed Scope and Location ofWork: c�ty: Edv►rards state: CO Z� p: 81632 Se � attached Scope of work letter Contact Ivame: DOI"iS Med 'Ina Contact Phone: 970 - 926-8788 E-Ma ; i dc� ris@superioralarmco . COCTI (use additional sheet if necessary) DoeS a Monitored Fire Alarm Exist? Yes � No � I hereby acknowledge that I have read this application , filled out in full the information required , completed an accurate fire alarm sys- Doe:� a Sprinkler System Exist? Yes � No � tem drawings and state that all the information as required is cor- rect. I agree to comply with the information and fire alarm system Wor6c Class : drawings, to comply with all Town ordinances and state laws , and to build this 5tructure according to the towns zoning and subdivision New (� Addition (�) Remodel (Q) Repair (Q) codes , design review approval , National Fire Code, International Retro-Fit (� Other (� Building and Residential Codes and other ordinances of the Town appli le thereto. �~ Typ� of Building: Single- Family �) Duplex (�j Multi-Family (� x Commercial (� Restaurant (�j Other Contr r ignature (required) � Property Nnformation Complefe Valuation for Fire Alarm Permit: Parcel #: 2101 -082- 1300-9 Fire Alarm $ : 41 , 2 � 2 . 74 (For parcel #, contact Eagle County Assessors Office at 970-328-8640 or visit www. e�glecounty. us/patie) Tenant Name: Date Received : owner Name: SWCPM LLC 13-Apr 01 � � � � � ' � � � � � � � � � � � � � � � � � Security, Fire , CCTV, Access Control , Custom Audio/Video , and Automation October 18 , 2013 Vail Fire and Emergency Services I�like Vaughan 42 W . Meadow Dr. Vail , CO 81657 fde : Scope of Work Letter—Christiana 356 E . Hanson Ranch Road Vail , Colorado 80657 Dear M i ke : We have been contracted to replace the fire alarm system at the Christiana located in Vail Village . 1-he scope of the project is a device for device replacement of the existing fire system . We will be replacing the existing conventional Firelite Sensiscan 200 with an addressable Silent Knight SK- 5820XL . Our installation will be performed in accordance with all local and national codes . The device list for the installation will consist of: Model Description Count SD505 -AHS 135 fixed temp heat detector 22 SY-5604 194 fixed temp heat detector 2 SD500-ARM Addressable relay module 5 SD505-6SB Addressable sounder base 55 SYS- P2R Horn/Strobe combo 14 SD505-APS Photo electric smoke detectors 91 SK-5860 Remote annunciator 1 SK-5815XL SLC expansion module 1 SYS-S R Strobe 3 SD500-MIM Transponder 35 12V 35AH Panel back up batteries 2 Daniel Dimitrov NICET II – Fire Alarm Systems Cert . # 119879 ��r��r �l�i� �������� P: 970.926. 8788 F: 970.926. 8790 Post Office Box 4910 ♦ Edwards , Colorado 81632 ♦ Phone (970 ) 926-8788 ♦ Fax (970 ) 926-8790 www. superioralarmco . com ♦ admin@superioralarmco . com �-'"�tptL �J�{�.a-,,�, 1 ' Y' �.^� 4 a`� 'Sh��il�`�py}� a Y 5�,. � � ��ny . ��f '� �" � � Fire Department Process n k For Commercial & Resodential Fire Alarm Systems �5 .' �. � � �.��� wµ,� ,�.�_�� � �,�, � ����r ��;�� Commer�ial and Residential Fire Alarm shop drawing requirerments at the time of submittal must include the following : A Colorado Registered Engineer' s stamp Device locations on reflected ceiling plans Reflected Ceiling Plans ( RCP) Typical device wiring diagrams � � attery calculations Battery calculations � A list of specific device model numbers X Equipment cut sheets of each type of device X The number of each type of device Information indicating the specific zones Circuit diagrams Point to point wiring diagram Wiring type , size and number of conductors The source of AC power circuits Fire alarm panel locations Knox Box location X Information indicating monitoring method and monitoring agency This che�k list has been provided to ensure that our review prucess may be handled in a timely manner . I have read and understand the above listed submittal requirements : Project/Street Address : 356 Hanson Ranch Road � Contractor Signature . �'�'' Date Sig � ed : .� O 1 -feb- 10 -�v�� ��,��o.,,, a/' �,r "+� R � �. �� � � e;.; ,� �ti, ��� _ ��� Fire Depart�nent Guidelines , �`s�; �� For Preventing Non -Emergency Fire Alarms # ,��` ���, ` , �,� �..�� �,�,., ��„ ,, .�.- � '����,r:$�.�`'-.- In order to prevent a non-emergency response from the Vail Fire Department Suppression crews to the con - struction location you may be working on , we ask that you per�orm the following tasks : Determine what kind of fire alarm system exists within the structure you are working in with the owner or th� manager of the property involved or by contact- � ing the Vail Fire Department. Determine with the owner or manager of the property , which alarm company X services the system for them Become familiar with the differ� nt components that are associated with the fire X alarm system and how they operate before the DEMO begins. Never paint a smoke detector, thermal detector, or any other component of the X fire alarm system and never paint a sprinkler head/cover plate . For larger projects , please contact the Vail Fire Department so that we can work with you in determining what needs to be done to alter or "Zone Out" spe- X cific areas of the alarm system for the structure . Please contact the Vail Fire Department at 479 -2252 . I have read and understand the above listed submittal requirements : Project/Street Address : 356 Hanson Ranch Road ,� Contract� r Signature : ,�� m � ���-°� Date Sigu� ed : � - � O 1 -R3g- 10 ^""��.lt� �11� + �a . x ,,• �.;, „,� w,�a"w� ���� z � �� . �,.�r� `�,�, �, � �� . ( � Fire Department Guidelines , `s� � Pre-Plan Informatio �n Sheet ����y M��� ��"��.��'��"�:�^��. BUILDII�G INFORMATION : Building Name : Street Address & Phone # e Knox Box Location : Alarm Panel Location : Mechanical Room Vail Fire & Emergency Services Alarm Silence & Rest Codes : 2252 RPS ' : Names & Phone Numbers (Work & Horme) Owner: Property Manager: John Everly 476-7445 Property Maintenance Mgr: Dallas or Mark 476-7445 Alarm S� rvice Company : Superior Alarm & Electronics Bl11LDING UTILITIES : Gas : Main Location : Other Locations : Electric : Main Location : Other Locations : Water : Main Val�ve Location : Main Fir� Valve Location : Secondary Fire Valve Loc: O1 -Feb- 10 ` Town of Vail w=°: ° < �� Fire Permit Fee Schedule � �� �,� ` �' Instructiions for calculating FIRE ALARM or SPRINKLER permit fees (see applicable section below) : 1 . Determine the valuation ( labor & materials) 2 , See base Permit Fee (flat fee) 3 . Calculate the Plan review fee ( multiply the valuation by the applicable percentage listed) Fire Alarm : Permit Fee : 3 . 75% of the valuation Plan Re�uiew Fee : $288 . 00, due at permit submittal Fire Sarinkler : Permit Fee : 4. 25% of the valuation Plan Re�uiew Fee : $432 . 00, due at permit submitta) OTHEft �ire Permit Fees : • Permits issued under a Scope of Work letter shall be assessed a fee not less than $ 144 . 00 and may be increased at a rate of $ 72 . 00 per hour for inspections, revisions, and similar el � ments . • Re-inspections and plan review for re-submittals shall be billed at $ 72 . 00 per hour. • Operational Permits, Special Event Permits, and Construction Permits other than those required for Fire Atarm and Fire Sprinkler systems, issued under provisions of the International Fire Code shall be based on an hourly rate of $72 . 00 per hnur per person for site inspections, plan review and permit processing .