HomeMy WebLinkAboutDRB130497 Action Form, Application, Approved PlansProjectName:DASNODE10@L.H. STRUCTURE DRBNumber: DRB130497
ProjectDescription:
REPLACEEXISTINGPOLEWITHANEWDASPOLEANDINSTALLNEWCONDUITTOCONNECT
WITHTHEEQUIPMENTCABINETLOCATEDONTHENORTHSIDEOFTHEGARAGE.
Participants:
OWNER TOWNOFVAIL 10/16/2013
75SFRONTAGERD
VAIL, CO
81657
CONTRACTORASPENWIRELESSTECHNOLOGIES10/16/2013 Phone: 970-948-9998
JIMSELBY
1920W. BURNLEYLANE
MAPLECITY
MI 49664
License: C000003839
APPLICANT CROWNCASTLE 10/16/2013 Phone: 602-677-0957
5853N48THST
STE305
CHANDLER
AZ 85226
ProjectAddress:350SFRONTAGERDWVAILLocation:
LIONSHEADPARKINGSTRUCTURE
LegalDescription:Lot: 1Block: 2Subdivision: VAILLIONSHEADFIL1
ParcelNumber:2101-064-0701-2
Comments:Pleaseseebelow.
BOARD/STAFFACTION
MotionBy: Action: STAFFAPP
SecondBy:
Vote: DateofApproval: 10/24/2013
Conditions:
Cond: 8
PLAN): NochangestotheseplansmaybemadewithoutthewrittenconsentofTownof
Vailstaffand/ortheappropriatereviewcommittee(s).
Cond: 0
PLAN): DRBapprovaldoesnotconstituteapermitforbuilding. Pleaseconsultwith
TownofVailBuildingpersonnelpriortoconstructionactivities.
Cond: 201
PLAN): DRBapprovalshallnotbecomevalidfor20daysfollowingthedateof
approval, pursuanttotheVailTownCode, Chapter12-3-3: APPEALS.
Cond: 202
PLAN): Approvalofthisprojectshalllapseandbecomevoidone (1) yearfollowing
thedateoffinalapproval, unlessabuildingpermitisissuedandconstructionis
commencedandisdiligentlypursuedtowardcompletion.
Cond: CON0013464
Equipmentcabinetsandassociatedcablesshallbepaintedtomatchthecolorofthe
parkinggargeexterior.
Planner:JonathanSpence DRBFeePaid: $250.00
By David Rhoades at 1:15 pm, Oct 15, 2013
DRB130497
PRJ13-0618
VAIL LIONSHEAD FILING 121
11/20/2013
By David Rhoades at 1:20 pm, Oct 15, 2013
DRB130497
DESIGN REVIEW
ADMINISTRATIVE APPROVAL
By jspence at 4:53 pm, Oct 24, 2013
DESIGN REVIEW
ADMINISTRATIVE APPROVAL
By jspence at 4:53 pm, Oct 24, 2013
DESIGN REVIEW
ADMINISTRATIVE APPROVAL
By jspence at 4:54 pm, Oct 24, 2013
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GRC-2''GRC-2''
GRC-2''GRC-2''
GRC-2''
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GRC-2''GRC-2''
GRC-2''GRC-2''GRC-2''
NODE 10
SE
T
P
O
W
E
R
ME
T
E
R
(
E
A
S
T
)
OF
T
R
A
N
S
F
O
R
M
E
R
ON
W
O
O
D
P
O
S
T
/
)
*
5
&
(
/
(
&
7
5
,
&
$
/
CO
N
D
U
I
T
T
O
N
O
D
E
W
/
4
8
0
V
S
E
R
V
I
C
E
2
-
#
2
R
H
H
-
U
S
E
-
R
H
W
C
O
P
P
E
R
W
I
R
E
S
1
-
#
6
C
O
P
P
E
R
G
R
O
U
N
D
W
I
R
E
/)*5$<
(
/
(
&
7
5
,
&
$
/
&
2
1
'
8
,
7
TO POWER ME
T
E
R
W
/
1
2
0
V
S
E
R
V
I
C
E
2 - #2 RHH-USE
-
R
H
W
C
O
P
P
E
R
W
I
R
E
S
1 - #6 C
O
P
P
E
R
G
R
O
U
N
D
W
I
R
E
PARKING STRUCTURE
FI
B
E
R
O
P
T
I
C
CO
N
D
U
I
T
EXISTING 12
0
/
2
0
8
T
R
A
N
S
F
O
R
M
E
R
.
CONNECTI
O
N
T
O
P
O
W
E
R
M
E
T
E
R
M
A
D
E
B
Y
H
O
L
Y
C
R
O
S
S
(NO S
E
R
V
I
C
E
B
O
X
N
E
E
D
E
D
)
48
0
V
-
1
2
0
/
2
4
0
V
10
K
V
A
T
R
A
N
S
F
O
R
M
E
R
480V - 120/240V10KVA TRANSFORMERON POLENODE#10LIONSHEADVILLAGEI-70/US-6VAILVILLAGEHUB WALL MOU
N
T
E
D
PULL BOX
(
T
Y
P
)
NO
D
E
C
A
B
I
N
E
T
NO
D
E
S
I
T
E
TR
E
N
C
H
T
H
R
E
E
1
1
/
4
-
I
N
C
H
C
O
N
D
U
I
T
S
(
B
L
U
E
,
G
R
E
E
N
&
R
E
D
)
ON
E
2
-
I
N
C
H
E
L
E
C
T
R
I
C
A
L
C
O
N
D
U
I
T
(
G
R
A
Y
)
BE
L
CO
M
M
U
N
I
C
A
T
I
O
N
S
V
A
U
L
T
(
2
'
x
3
'
)
CO
M
M
U
N
I
C
A
T
I
O
N
S
V
A
U
L
T
(
3
'
x
4
'
)
EL
E
C
T
R
I
C
A
L
V
A
U
L
T
(
3
'
x
4
'
)
BO
R
E
T
H
R
E
E
1
1
/
4
-
I
N
C
H
C
O
N
D
U
I
T
S
(
B
L
U
E
,
G
R
E
E
N
&
R
E
D
)
BO
R
E
EX
I
S
T
I
N
G
C
O
N
D
U
I
T
EX
I
S
T
I
N
G
V
A
U
L
T
EX
I
S
T
I
N
G
T
R
A
N
S
F
O
R
M
E
R
PO
W
E
R
M
E
T
E
R
EX
I
S
T
I
N
G
E
L
E
C
T
R
I
C
A
L
S
E
R
V
I
C
E
B
O
X
NE
W
E
L
E
C
T
R
I
C
A
L
S
E
R
V
I
C
E
B
O
X
SE
C
O
N
D
A
R
Y
T
R
A
N
S
F
O
R
M
E
R
GR
C
-
4
'
'
ON
E
4
-
I
N
C
H
G
A
L
V
A
N
I
Z
E
D
R
I
G
I
D
C
O
N
D
U
I
T
NO
D
E
C
A
B
I
N
E
T
CONTACT HOL
Y
C
R
O
S
S
E
N
E
R
G
Y
FOR ALL POWE
R
C
O
N
N
E
C
T
I
O
N
S
& INSTALLATIO
N
S
O
F
S
E
R
V
I
C
E
B
O
X
E
S
.
BOB SAATHOF
F
9
7
0
-
2
7
4
-
2
5
1
0
09
/
1
8
/
2
0
1
3
OCT.10.2013
ISSUE DATE:
SHEET NUMBER:
SHEET TITLE:
NODE:
SITE INFORMATION:
PLANS PREPARED BY:
DAS INSTALLATION
2000 CORPORATE DRIVE
CANONSBURG, PA 15317
aZ@ZYmR.co
COPYRIGHT2013 Studio Z Architecture, LLC
LIMITATION OF WARRANTY AND
ARCHITECT'S WORK PRODUCT:
SEAL:
ELECTRICAL PLAN
E-1
GENERAL PROJECT NOTES
1.THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A COMPLETE
AND FUNCTIONING ELECTRICAL SYSTEM.
2.MATERIALS AND INSTALLATION SHALL COMPLY WITH CODES, LAWS AND ORDINANCES OF
FEDERAL, STATE AND LOCAL GOVERNING BODIES HAVING JURISDICTION.
3.ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW, UNLESS SPECIFICALLY
INDICATED AS EXISTING TO BE REUSED.
4.PROVIDE COMPLETE METALLIC RACEWAY SYSTEMS AND ENCLOSURES FOR ALL WIRING
THROUGHOUT THE EXTENT OF THE REQUIRED SYSTEM.
5.FINAL CONNECTIONS TO EQUIPMENT SHALL BE MADE WITH LIQUID TIGHT FLEXIBLE STEEL
CONDUIT, 1/2 INCH MINIMUM.
6.ALL CONDUCTORS INSTALLED IN INTERIOR DRY LOCATIONS SHALL BE TYPE THWN OR THHN
THERMOPLASTIC 600V INSULATED COPPER CONDUCTORS.NO WIRE SMALLER THAN NO. 12
SHALL BE USED FOR LIGHTING OR POWER WIRING. WIRE NO. 8 AND LARGER SHALL BE
STRANDED. ALL CONDUCTORS INSTALLED IN EXTERIOR OR WET LOCATIONS SHALL BE TYPE
THWN 600V INSULATED COPPER CONDUCTORS.
FAULT CURRENT CALCULATION TABLE
NOTES:
1.
2.
3.
4.
5.
LOCATION (n)
50
Utility Meter
(LOAD CENTER)
All Calculations utilize Bussman "Point-To-Point" Method.
Variables:
Transformer shall be maximum 50kVA with minimum 15-foot secondary. Notify Engineer of any discrepancy.
Conductor lengths shall not be less than the values listed. The E.C. shall field verify conductor lengths and contact
engineer immediately if conductor lengths are less than the values shown.
Conductor Lengths listed in this table are for fault study purposes only and shall not be used for bidding or other calculations.
# of RUNS
kVA Utility Transformer
1
L=Feeder Length (LF)
C=Conductor "C" Value
CONDUCTOR
4
V(L-L)
240
240
0Q ·IQ
F(n)=F(n-1) x M(n)
V(L-N)
120
120
1=Steel
2=Non-Mag
2
L(ft)
15
f(n)(L-L) = (2 x L x F(L-L)(n-1))/(C x # of runs x VOLTAGE) in Amperes
f(n)(L-N) = (2 x L x F(L-N)(n-1))/(C x # of runs x VOLTAGE) in Amperes
C
3,826
f(L-L)
0.48
f(L-N)
1.42
M(L-L)
0.67
October 10, 2013
M(L-N)
0.41
F(L-L)
14,800
9,976
F(L-N)
21,700
8,975
ELECTRICAL LEGEND
NOTE: NOT ALL ITEMS APPEAR ON DRAWINGS.
SYMBOLS MAY DIFFER FROM EXISTING AND
DEMO WORK OR DEVICES REFERENCED FROM
DRAWINGS BY OTHERS.
T
ABBREVIATIONS
E.C.
WP
GFI
TRANSFORMER
GROUND FAULT INTERRUPTING
ELECTRICAL CONTRACTOR
WEATHER PROOF
ELECTRICAL PANEL BOARD
EQUIPMENT DISCONNECT SWITCH
EQUIPMENT FUSED DISCONNECT SWITCH
REFERENCE SYMBOLS
FEEDER - SEE SCHEDULE
XFMR
kVA
TRANSFORMER WITH GROUNDING AND
OVERCURRENT DEVICES SEE
TRANSFORMER SCHEDULE
#/W
XX
AHJ AUTHORITY HAVING JURISDICTION
60S/3
#6 Cu G, 3/4"C
N
G
GRADE LEVEL
SERVICE RATED NEMA 3R
PANELBOARD APPROVED BY LOCAL
UTILITY WITH UTILITY METER, MAIN
BREAKER AND MINIMUM 4-CIRCUITS
MOUNTED ON POLE
60S/3 3#4 Cu, 1"C
Feeder Schedule
Conductors shall be sized and
installed in accordance with NEC.
TO UTILITY TRANSFORMER
(50kVA MAXIMUM) 240/120V,
1-PHASE, 3W SECONDARY,
FIELD VERIFY
BOND AND GROUND PER NEC 250
x GROUND RODS
x GROUND RING
x STEEL
PROVIDE ADDITIONAL GROUNDING PER
EQUIPMENT PROVIDER REQUIREMENTS
20A
20A
ELECTRICAL ONE LINE DIAGRAM
SCALE: N.T.S.
1
E-1
60/2
20A PANEL 'A'
20A
PANEL SCHEDULE:
BUS RATING:
MAIN C.B.:
MOUNTING:
COMMENTS:
CIR
NO.
1
3
CIRCUIT
AMPS
20
20
60A
60A/2P
Surface
New Panelboard, NEMA 3R, Service Rated
BREAKER
POLE
1
1
PHASE A (VA):
PHASE B (VA):
TOTAL LOAD (VA):
:,5(
or M.L.O:
CONNECTED
LOAD (VA)
500
500
1,000
A
NEC DEMAND
FACTOR
DESCRIPTION OF
LOAD SERVED
Spare
Spare
PHASE
A
B
VOLTAGE L-L:
VOLTAGE L-G:
S.C.RMS RATING (AIC):
DESCRIPTION OF
LOAD SERVED
Cabinet #1
Cabinet #2
PHASE A (VA):
PHASE B (VA):
TOTAL DEMAND LOAD (VA):
240
120
22,000
NEC DEMAND
FACTOR
1.00
1.00
500
500
1,000
October 10, 2013
CONNECTED
LOAD (VA)
500
500
4.17
CIRCUIT
POLE
1
1
A
BREAKER
AMPS
20
20
CIR
NO.
2
4
MINIMUM 15'
M
DRB130497
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GRC-2''GRC-2''
GRC-2''GRC-2''
GRC-2''
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GR
C
-
2
'
'
GRC-2''GRC-2''
GRC-2''GRC-2''GRC-2''
NODE 10
SE
T
P
O
W
E
R
ME
T
E
R
(
E
A
S
T
)
OF
T
R
A
N
S
F
O
R
M
E
R
ON
W
O
O
D
P
O
S
T
/
)
*
5
&
(
/
(
&
7
5
,
&
$
/
CO
N
D
U
I
T
T
O
N
O
D
E
W
/
4
8
0
V
S
E
R
V
I
C
E
2
-
#
2
R
H
H
-
U
S
E
-
R
H
W
C
O
P
P
E
R
W
I
R
E
S
1
-
#
6
C
O
P
P
E
R
G
R
O
U
N
D
W
I
R
E
/)*5$<
(
/
(
&
7
5
,
&
$
/
&
2
1
'
8
,
7
TO POWER ME
T
E
R
W
/
1
2
0
V
S
E
R
V
I
C
E
2 - #2 RHH-USE
-
R
H
W
C
O
P
P
E
R
W
I
R
E
S
1 - #6 C
O
P
P
E
R
G
R
O
U
N
D
W
I
R
E
PARKING STRUCTURE
FI
B
E
R
O
P
T
I
C
CO
N
D
U
I
T
EXISTING 12
0
/
2
0
8
T
R
A
N
S
F
O
R
M
E
R
.
CONNECTI
O
N
T
O
P
O
W
E
R
M
E
T
E
R
M
A
D
E
B
Y
H
O
L
Y
C
R
O
S
S
(NO S
E
R
V
I
C
E
B
O
X
N
E
E
D
E
D
)
48
0
V
-
1
2
0
/
2
4
0
V
10
K
V
A
T
R
A
N
S
F
O
R
M
E
R
480V - 120/240V10KVA TRANSFORMERON POLENODE#10LIONSHEADVILLAGEI-70/US-6VAILVILLAGEHUB WALL MOU
N
T
E
D
PULL BOX
(
T
Y
P
)
NO
D
E
C
A
B
I
N
E
T
NO
D
E
S
I
T
E
TR
E
N
C
H
T
H
R
E
E
1
1
/
4
-
I
N
C
H
C
O
N
D
U
I
T
S
(
B
L
U
E
,
G
R
E
E
N
&
R
E
D
)
ON
E
2
-
I
N
C
H
E
L
E
C
T
R
I
C
A
L
C
O
N
D
U
I
T
(
G
R
A
Y
)
BE
L
CO
M
M
U
N
I
C
A
T
I
O
N
S
V
A
U
L
T
(
2
'
x
3
'
)
CO
M
M
U
N
I
C
A
T
I
O
N
S
V
A
U
L
T
(
3
'
x
4
'
)
EL
E
C
T
R
I
C
A
L
V
A
U
L
T
(
3
'
x
4
'
)
BO
R
E
T
H
R
E
E
1
1
/
4
-
I
N
C
H
C
O
N
D
U
I
T
S
(
B
L
U
E
,
G
R
E
E
N
&
R
E
D
)
BO
R
E
EX
I
S
T
I
N
G
C
O
N
D
U
I
T
EX
I
S
T
I
N
G
V
A
U
L
T
EX
I
S
T
I
N
G
T
R
A
N
S
F
O
R
M
E
R
PO
W
E
R
M
E
T
E
R
EX
I
S
T
I
N
G
E
L
E
C
T
R
I
C
A
L
S
E
R
V
I
C
E
B
O
X
NE
W
E
L
E
C
T
R
I
C
A
L
S
E
R
V
I
C
E
B
O
X
SE
C
O
N
D
A
R
Y
T
R
A
N
S
F
O
R
M
E
R
GR
C
-
4
'
'
ON
E
4
-
I
N
C
H
G
A
L
V
A
N
I
Z
E
D
R
I
G
I
D
C
O
N
D
U
I
T
NO
D
E
C
A
B
I
N
E
T
CONTACT HOL
Y
C
R
O
S
S
E
N
E
R
G
Y
FOR ALL POWE
R
C
O
N
N
E
C
T
I
O
N
S
& INSTALLATIO
N
S
O
F
S
E
R
V
I
C
E
B
O
X
E
S
.
BOB SAATHOF
F
9
7
0
-
2
7
4
-
2
5
1
0
09
/
1
8
/
2
0
1
3
DR
B
1
3
0
4
9
7