Loading...
HomeMy WebLinkAboutDRB130527 APPLICATION.pdf Department of Community Development 75 South Frontage Road T{)1PI OF VA1L" Vail,CO 81657 Tel: 970-479-2128 www.vailgov.com Development Review Coordinator Application for Design Review New Construction General Information: This application is for all new construction. Applicable Vail Town Code sections can be found at www.vailgov.com under Vail Information - Town Code Online. All projects requiring design review must receive approval prior to submitting a building permit application. An application for Design Review cannot be accepted until all required information is received by the Community Development Department, as outlined in the submittal requirements. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission. Design review approval expires one year from the date of approval, unless a building permit is issued and construction commences. Fee: $650 rm ❑ Single Family 11 Duplex ❑ Multi-Family Commercial / Description of the Request: A'e, l,cnshead Y-[✓-.ernt .Sfr'C4'-a ry rL) and l ano�J� Physical Address: �'�50 S. 15rc"tide Parcel Number: Rio/- 064-b7-d /Z (Contact Eagle Co. Assessor at 970-328-8640 for parcel no.) Property Owner: 1&ion nr ✓c, r Mailing Address: -75 S- �r. ( i l ) CD 916S-7 Phone: 970 -c-/79 27-3S Owner's Signature: Primary Contact/Owner Representative: SSm Mailing Address: —,7 6i_ . Lla, rj CO 6/bS7 Phone: 970 479 -2 2 35 E-Mail: � Ls 5«e l@ 161lGw- Cr'� Fax: For Office Use Only: Cash CC: Visa/MC Last 4 CC# Exp. Date: Auth# Check# Fee P_aid: Received From: Meeting Date: DRB No.: Planner: Project No.: Zoning: Land Use: Location of the Proposal: Lot: Block: Subdivision: TOWN OF VAIL "' The Lionshead Parking Structure Entry Improvements October 28 , 2013 Summary The Town of Vail owns and operates two public parking structures, one in the Vail Village and one in Lionshead Village. The Lionshead Village parking structure is in need of an improved entry to enhance operations, efficiency, safety, aesthetics and provide a level of guest service expected at a world class resort. The proposed project will include building a canopy structure over a new entry and exit, as well as increase queuing capacity for vehicles. The project will also improve the skier drop off safety, efficiency and experience at the lowest level of the parking structure by creating a one way skier drop off loop. The canopy structure will be compatible with the architecture and lighting of the two most recent Lionshead Parking Structure buildings;the Lionshead Transit Center and Welcome Center. The improvements will maintain the existing uses of the parking structure, while improving the operations, efficiency, safety, aesthetics and provide a level of guest service expected at a world class resort. Vantage Point Gary A. Lebo PO BOX 178 AVON, CO 81620, United States Vail 21 Destination Resort Mgt, Inc, 610 W LIONSHEAD CIR VAIL, CO 81657, United States VAIL 21 PARKING GARAGE NO. 1 LLC VAIL 21 PARKING GARAGE NO. 2 LLC 610 W LIONSHEAD CIR STE 100 VAIL, CO 81657 Treetops Vicki L. Brown 450 E. Lionshead Circle Vail, CO 81657, United States Lodge at Lionshead JEFF BAILEY 380 E LIONSHEAD CR VAIL, CO 81657, United States Vail International SMITH SNOWDEN 300 E LIONSHEAD CIR VAIL, CO 81657, United States LIONSHEAD PARKING ENTRANCE as° [1219mm] Configuration ®EI OEI- - �Q ry' N 44 Yv 90° - u]� {}Q o � 96 p 27 0° Qty Bracket TER4MA-1A-90DEG-BKTX Description of Components: Arm: Spun from a 3 1/2" (89mm) round aluminum 6063-T4 tubing, tempered to T6 after welding, wall thickness of 0.125" (3mm), tapered and ovalized, ending in a straight 2 3/8" (60mm) diameter tenon, 6" (152mm) long. Mounting Plate: Universal aluminum mounting plate to adapt on square or round poles, wood or metal. Bracket Options: (90DEG),Bracket to be oriented at 90 degree from access door. SPEC20130822_114740_8499_3 10-22-2013 Page 1 / 3 PHILIP LUEC LIONSHEAD PARKING ENTRANCE Base&Bolts Information Anchor Plate Free opening 6 8MM -Bolt Circle: 1 681: 10 1/2"(267mm) 3 112"(89mm) Pole Shaft Section Projection Material: Cast Aluminum ' ' NOTE: Comes with 4 steel anchor bolts, 1" Bolt Circle Allowed: �' 33"+3",8 nuts and 8 washers. 10"to 11" Important: Do not obstruct space 254mm to 279mm 11.28° 0 between anchor plate and concrete 286mm base. Qty Pole USS704OC-24-BKTX Description of Components: Pole Shaft: Shall be made from spun aluminum 6063-T4, tempered to T6 after welding, having a base diameter of 7" (178mm) and top diameter of 4" (102mm), wall thickness of 0.188" (4.8mm)welded to both the bottom and top of the anchor plate. n Maintenance Opening: The pole shall have a 4" x 7" (102mm x 178mm) maintenance ° opening centered 18" (457mm) from the bottom of the anchor plate, complete with a weatherproof aluminum cover and a ground lug. Nut cover: Made from cast 356 aluminum, mechanically fastened with stainless steel screws. _ Q � E a SPEC20130822_114740_8499_3 10-22-2013 Page 2/3 PHILIPS LUEC LIONSHEAD PARKING ENTRANCE Miscellaneous Description of Components: Finish: Color to be black textured RAL9005TX (BKTX) and in accordance with the AAMA 2603 standard. Application of a polyester powdercoat paint (4 mils/100 microns)with ± 1 mils/24 microns of tolerance. The Thermosetting resins provides a discoloration resistant finish in accordance with the ASTM D 2244 standard, as well as luster retention in keeping with the ASTM D 523 standard and humidity proof in accordance with the ASTM-D2247 standard. The surface treatment achieves a minimum of 2000 hours for salt spray resistant finish in accordance with testing performed and per ASTM-6117 standard. Hardware: All exposed screws shall be stainless steel. SPEC20130822_114740_8499_3 10-22-2013 Page 3/3 PHILIPS LUEC LIONSHEAD PARKING ENTRANCE Base&Bolts Information Anchor Plate Free opening 4 1f -Bolt Circle: 1 14rnm 12 1/2"(318mm) 0 112"(89mm) Pole Sheft Section Projection Thickness: r NOTE: Comes with 4 steel anchor bolts, 1"> Bolt Circle Allowed: 33"+3",8 nuts and 8 washers. 8"to 12 1/2" Important: Do not obstruct space 203mm to 318mm between anchor plate and concrete 292mm base. M-ERt4R Ltd MINE) Qty Pole SPR5V-20-CAP4-BKTX Description of Components: Pole Shaft: Shall be made from a 5" (127mm) round high tensile carbon steel tubing, having a 0.250" (6.4mm) wall thickness, welded to both the bottom and top of the anchor plate. ° Maintenance Opening: The pole shall have a 2" x 4 1/2" (51mm x 114mm) ° maintenance opening centered 20" (508mm) from the bottom of the anchor plate, complete with a weatherproof aluminum cover and a copper ground lug. Base Cover: Two piece square base cover made from formed aluminum, mechanically fastened with stainless steel screws. Pole Options: (CAP4) Optional Pole Cap Note: A tenon will be provided when the luminaire or bracket does not fit directly on pole shaft. Tenon not shown on the drawing. IMPORTANT: Philips Lumec strongly recommends the installation of the complete lighting assembly with all of its accessories upon the anchoring of the pole. This will -- 0 ensure that the structural integrity of the product is maintained throughout its lifetime. Q� N Q 12 l 2p 31 Bmm SPEC20130822_114723_8499_4 10-22-2013 Page 1 /2 PHILIPS LUEC LIONSHEAD PARKING ENTRANCE Miscellaneous Description of Components: Hardware: All exposed screws shall be stainless steel with Ceramic primer-seal basecoat to reduce seizing of the parts. All seals and sealing devices are made and/or lined with EPDM and/or silicone and/or rubber. Finish: Color to be black textured RAL9005TX (BKTX) and in accordance with the AAMA 2603 standard. Application of a polyester powdercoat paint (4 mils/100 microns)with ± 1 mils/24 microns of tolerance. The Thermosetting resins provides a discoloration resistant finish in accordance with the ASTM D 2244 standard, as well as luster retention in keeping with the ASTM D 523 standard and humidity proof in accordance with the ASTM-D2247 standard. The surface treatment achieves a minimum of 2000 hours for salt spray resistant finish in accordance with testing performed and per ASTM-13117 standard. Quality Control: The manufacturer must provide a written confirmation of its ISO 9001-2008 and ISO 14001-2004 International Quality Standards Certification. Mechanical resistance: In order to ensure the mechanical resistance of the poles, the reflected area should be calculated according to AASHTO standards and resists to a wind of 140 km/hr. Web site information details: / ISO 9001-2008 Certification / ISO 14001-2004 Certification / CSA Pole Certification SPEC20130822_114723_8499_4 10-22-2013 Page 2/2 PHILIPS LUEC