Loading...
HomeMy WebLinkAboutPEC130032 APPLICATION.pdf Department of Community Development 75 South Frontage Road TOWN Of VAIL Vail,CO 81657 Tel: 970-479-2128 www.vailgov.com Development Review Coordinator Conditional Use Permit Application for review by the Planning and Environmental Commission General Information: A conditional use permit is required for any use classified as "conditional" in any of the Town's zone districts. Uses listed as conditional uses are subject to such conditions and limitations as the Town may prescribe to ensure that the location and operation of the conditional uses will be in accordance with development objectives of the Town and will not be detrimental to other uses or properties. The pro- posed project may also require other permits or applications and/or review by the Design Review Board and/or Town Council. All PEC approvals shall lapse if construction is not commenced within two years of the date of approval and diligently pursued to completion, or if the use for which the approval is granted is not commenced within two years. Fee: $650 --�� Description of the Request: A)Iiv 41WSke"( 7'�i'&' 47�_VC)7�),e t`-/ h Apr Physical Address: 9yo S , rT&"-AzzC e KC -_/ Parcel Number: 1/0/ -/J( tl- (J 17- t/2 (Contact Eagle Co. Assessor at 970-328-8640 for parcel no.) Property Owner: _�/7 47 Ya, I Mailing Address: 75 ) Co g J SrJ r Phone: 970 -47z)-Z231:� Owner's Signature: � h_ Primary Contact/Owner Representative: T E 4 ssm c Mailing Address: /_:k, /l r Phone: 276 /22 0-7 35 E-Mail: C/assrne E I/ae 16c-y- (mm Fax: 9?X x/79 2 /&(p For Office Use Only: Cash_ CC: Visa/MC Last 4 CC# Exp. Date: Aulh# Check# Fee Paid: Received From: Meeting Date: PEG No.: Planner: Project No: Zoning: Land Use: Location of the Proposal: Lot: Block: Subdivision: TOWN OF VAIL "' The Lionshead Parking Structure Entry Improvements October 28 , 2013 Summary The Town of Vail owns and operates two public parking structures, one in the Vail Village and one in Lionshead Village. The Lionshead Village parking structure is in need of an improved entry to enhance operations, efficiency, safety, aesthetics and provide a level of guest service expected at a world class resort. The proposed project will include building a canopy structure over a new entry and exit, as well as increase queuing capacity for vehicles. The project will also improve the skier drop off safety, efficiency and experience at the lowest level of the parking structure by creating a one way skier drop off loop. The canopy structure will be compatible with the architecture and lighting of the two most recent Lionshead Parking Structure buildings;the Lionshead Transit Center and Welcome Center. The improvements will maintain the existing uses of the parking structure, while improving the operations, efficiency, safety, aesthetics and provide a level of guest service expected at a world class resort. Vantage Point Gary A. Lebo PO BOX 178 AVON, CO 81620, United States Vail 21 Destination Resort Mgt, Inc, 610 W LIONSHEAD CIR VAIL, CO 81657, United States VAIL 21 PARKING GARAGE NO. 1 LLC VAIL 21 PARKING GARAGE NO. 2 LLC 610 W LIONSHEAD CIR STE 100 VAIL, CO 81657 Treetops Vicki L. Brown 450 E. Lionshead Circle Vail, CO 81657, United States Lodge at Lionshead JEFF BAILEY 380 E LIONSHEAD CR VAIL, CO 81657, United States Vail International SMITH SNOWDEN 300 E LIONSHEAD CIR VAIL, CO 81657, United States LIONSHEAD PARKING ENTRANCE as° [1219mm] Configuration ®EI OEI- - �Q ry' N 44 Yv 90° - u]� {}Q o � 96 p 27 0° Qty Bracket TER4MA-1A-90DEG-BKTX Description of Components: Arm: Spun from a 3 1/2" (89mm) round aluminum 6063-T4 tubing, tempered to T6 after welding, wall thickness of 0.125" (3mm), tapered and ovalized, ending in a straight 2 3/8" (60mm) diameter tenon, 6" (152mm) long. Mounting Plate: Universal aluminum mounting plate to adapt on square or round poles, wood or metal. Bracket Options: (90DEG),Bracket to be oriented at 90 degree from access door. SPEC20130822_114740_8499_3 10-22-2013 Page 1 / 3 PHILIP LUEC LIONSHEAD PARKING ENTRANCE Base&Bolts Information Anchor Plate Free opening 6 8MM -Bolt Circle: 1 681: 10 1/2"(267mm) 3 112"(89mm) Pole Shaft Section Projection Material: Cast Aluminum ' ' NOTE: Comes with 4 steel anchor bolts, 1" Bolt Circle Allowed: �' 33"+3",8 nuts and 8 washers. 10"to 11" Important: Do not obstruct space 254mm to 279mm 11.28° 0 between anchor plate and concrete 286mm base. Qty Pole USS704OC-24-BKTX Description of Components: Pole Shaft: Shall be made from spun aluminum 6063-T4, tempered to T6 after welding, having a base diameter of 7" (178mm) and top diameter of 4" (102mm), wall thickness of 0.188" (4.8mm)welded to both the bottom and top of the anchor plate. n Maintenance Opening: The pole shall have a 4" x 7" (102mm x 178mm) maintenance ° opening centered 18" (457mm) from the bottom of the anchor plate, complete with a weatherproof aluminum cover and a ground lug. Nut cover: Made from cast 356 aluminum, mechanically fastened with stainless steel screws. _ Q � E a SPEC20130822_114740_8499_3 10-22-2013 Page 2/3 PHILIPS LUEC LIONSHEAD PARKING ENTRANCE Miscellaneous Description of Components: Finish: Color to be black textured RAL9005TX (BKTX) and in accordance with the AAMA 2603 standard. Application of a polyester powdercoat paint (4 mils/100 microns)with ± 1 mils/24 microns of tolerance. The Thermosetting resins provides a discoloration resistant finish in accordance with the ASTM D 2244 standard, as well as luster retention in keeping with the ASTM D 523 standard and humidity proof in accordance with the ASTM-D2247 standard. The surface treatment achieves a minimum of 2000 hours for salt spray resistant finish in accordance with testing performed and per ASTM-6117 standard. Hardware: All exposed screws shall be stainless steel. SPEC20130822_114740_8499_3 10-22-2013 Page 3/3 PHILIPS LUEC LIONSHEAD PARKING ENTRANCE Base&Bolts Information Anchor Plate Free opening 4 1f -Bolt Circle: 1 14rnm 12 1/2"(318mm) 0 112"(89mm) Pole Sheft Section Projection Thickness: r NOTE: Comes with 4 steel anchor bolts, 1"> Bolt Circle Allowed: 33"+3",8 nuts and 8 washers. 8"to 12 1/2" Important: Do not obstruct space 203mm to 318mm between anchor plate and concrete 292mm base. M-ERt4R Ltd MINE) Qty Pole SPR5V-20-CAP4-BKTX Description of Components: Pole Shaft: Shall be made from a 5" (127mm) round high tensile carbon steel tubing, having a 0.250" (6.4mm) wall thickness, welded to both the bottom and top of the anchor plate. ° Maintenance Opening: The pole shall have a 2" x 4 1/2" (51mm x 114mm) ° maintenance opening centered 20" (508mm) from the bottom of the anchor plate, complete with a weatherproof aluminum cover and a copper ground lug. Base Cover: Two piece square base cover made from formed aluminum, mechanically fastened with stainless steel screws. Pole Options: (CAP4) Optional Pole Cap Note: A tenon will be provided when the luminaire or bracket does not fit directly on pole shaft. Tenon not shown on the drawing. IMPORTANT: Philips Lumec strongly recommends the installation of the complete lighting assembly with all of its accessories upon the anchoring of the pole. This will -- 0 ensure that the structural integrity of the product is maintained throughout its lifetime. Q� N Q 12 l 2p 31 Bmm SPEC20130822_114723_8499_4 10-22-2013 Page 1 /2 PHILIPS LUEC LIONSHEAD PARKING ENTRANCE Miscellaneous Description of Components: Hardware: All exposed screws shall be stainless steel with Ceramic primer-seal basecoat to reduce seizing of the parts. All seals and sealing devices are made and/or lined with EPDM and/or silicone and/or rubber. Finish: Color to be black textured RAL9005TX (BKTX) and in accordance with the AAMA 2603 standard. Application of a polyester powdercoat paint (4 mils/100 microns)with ± 1 mils/24 microns of tolerance. The Thermosetting resins provides a discoloration resistant finish in accordance with the ASTM D 2244 standard, as well as luster retention in keeping with the ASTM D 523 standard and humidity proof in accordance with the ASTM-D2247 standard. The surface treatment achieves a minimum of 2000 hours for salt spray resistant finish in accordance with testing performed and per ASTM-13117 standard. Quality Control: The manufacturer must provide a written confirmation of its ISO 9001-2008 and ISO 14001-2004 International Quality Standards Certification. Mechanical resistance: In order to ensure the mechanical resistance of the poles, the reflected area should be calculated according to AASHTO standards and resists to a wind of 140 km/hr. Web site information details: / ISO 9001-2008 Certification / ISO 14001-2004 Certification / CSA Pole Certification SPEC20130822_114723_8499_4 10-22-2013 Page 2/2 PHILIPS LUEC