Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
F13-0045 HYDRAULICS, CUT SHEETS.pdf
VAIL AL1LEli' FIRE SPRINKLER CORPORATION 57 HEREFORD LANE EDWARDS, CO 81632 PH: (970) 914-5014 385 GORE CREEK DR. UNIT 204 385 GORE CREEK DRIVE VAIL, CO 81657 10/8/2011 EQUIPMENT SUBMITTAL Bulletin 006 Rev. F Model RFC30 (SIN RA0611) °J ® Model RFC43 (SIN RA0612) Model RFC49 (SIN RA0616) Rel bi Residential Flat Concealed Sprinklers A Residential Flat Concealed Sprinkler engineered for a minimum -- ` design density of 0.05 gpm/ft2 with Y low GPM requirements. Features OJ } 1. Very low water flow requirements. 2. 112" (13mm) Total adjustment. t 3. Thread-On/Thread-Off or Push-On/Thread Off cover attachment option. 4. Smooth aesthetic ceiling profile. 5. Available in brass, chrome and black plated or painted finishes. Listings & Approval 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) 2. NYC MEA 258-93-E UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC30, RFC43 and RFC49 Concealed Residen- the most dependable fire protection available, an automat- tial Sprinklers are fast response residential fusible solder is sprinkler system. link automatic sprinklers. Residential sprinklers differ from The RFC30, RFC43 and RFC49 are UL Listed Residential standard sprinklers primarily in their response time and Sprinklers to be installed in the residential portions of any water distribution patterns. occupancy in accordance with NFPA 13, 13R, & 13D. Model RFC30, RFC43 and RFC49 sprinklers discharge The RFC30, RFC43 and RFC49 can reduce the need for water in a hemispherical pattern below the sprinkler de- precise cutting of drop nipples. The threaded cover plate flector. Residential distribution patterns are higher and assembly can be adjusted without tools to fit accurately generally contain a finer droplet size than standard sprin- against the ceiling. The fire protection system need not be kler patterns. shut down to adjust or remove the cover plate assembly. The combination of speed of operation and high dis- Application and Installation charge pattern required for residential sprinklers has dem- The RFC30, RFC43 and RFC49, for residential installa- onstrated, in fire testing, an ability for controlling residen- tions, use a 165°F(74°C)fusible solder link in a tuning fork tial fires, and thereby providing significant evacuation time style sprinkler frame with a drop-down deflector. This as- for occupants. sembly is recessed into the ceiling and concealed by a flat The RFC30, RFC43 and RFC49 Sprinklers provide the cover plate. The cover plate is attached to the skirt, using best form of fire protection by combining an attractive ap- 135°F (57°C) ordinary temperature classification solder. pearance and 112" (13mm) of cover adjustment for ease of When the ceiling temperature rises, the solder holding installation. The small diameter cover plate is easily and the cover plate releases the cover allowing the deflector positively attached and blends into the ceiling, concealing to drop into position and exposing the sprinkler inside to The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 ceiling temperature. The subsequent operation of the sol- OF THE SPRINKLER/CUP ASSEMBLY. MODEL RFC30, der link opens the waterway and causes the deflector to RFC43 AND RFC49 CONCEALED SPRINKLERS MUST drop into position to distribute the discharging water in a BE INSTALLED ONLY WITH 135°F RATED COVERS. hemispherical pattern below the sprinkler deflector. Any Note:A leak tight'/2" NPT(R1/2) sprinkler joint can be ob- adjustment of thread engagement between the cover tained with a torque of 8-18 ft-lbs (10,8- 24,4 N-m). Do not plate and cup will assure that the drop-down deflector is tighten sprinklers over maximum recommended torque. It properly located below the ceiling. The residential distri- may cause leakage or impairment of the sprinklers. bution pattern contains a finer droplet size than a standard Cover assemblies provide up to 1/2" (13mm) of adjust- sprinkler, and the pattern produces significantly higher ment. Turn the cover clockwise until the flange is in con- wall wetting. tact with the ceiling. For the push-on/thread-off option, the After a 25/8 inch diameter hole is cut in the ceiling, the cover assembly is pushed onto the cup and final adjust- sprinkler is to be installed with the Model FC Wrench. ment is made by turning the cover clockwise until the skirt When installing a sprinkler, the wrench is first positioned flange makes full contact with the ceiling. Cover removal into the sprinkler/cup assembly and around the hexagonal requires turning in the counter-clockwise direction. body of the sprinkler frame. The Wrench must bottom out In ceilings that have a plenum space above the sprinkler, against the cup in order to ensure proper, safe installation. the plenum space may have neutral or negative pressur- The sprinkler is then tightened into the pipe fitting. When ization but must not be positively pressurized. Inspect all inserting or removing the wrench from the sprinkler/cup sprinklers after installation to ensure that the gap between assembly, care should be taken to prevent damage to the cover plate and ceiling and the 4 slots in the cup are the sprinkler. DO NOT WRENCH ON ANY OTHER PART all open and free from any air flow impediment. Temperature Rating Sprinkler Cover Plate Max.Ambient Temp. 165°F/74°C 135°F/57°C 100°F/38°C Installation Data: RFC30 (SIN RA0611) Thread Sprinkler Maximum Minimum Minimum Required Size K Factor Spacing Distance to Distance between Sprinkler Discharge inch (mm) ft. (m) Wall sprinklers Flow Press. ft. (m) ft. (m) gpm (Lpm) psi (bar) 1/2"(15mm) 3.0 12 x 12(3.6x3.6) 6(1.83) 8(2.43) 9(34.1) 9.0(0.62) 1/2"(15mm) 3.0 14 x 14(4.3x4.3) 7(2.13) 8(2.43) 10(37.8) 11 (0.76) Note: 1 bar=100 Kpa Installation Data: RFC43 (SIN RA0612) Thread Sprinkler Maximum Minimum Minimum Required Size K Factor Spacing Distance to Distance between Sprinkler Discharge inch (mm) ft. (m) Wall sprinklers Flow Press. ft. (m) ft. (m) gpm (Lpm) psi (bar) 1/2"(15mm) 4.3 12 x 12(3.6x3.6) 6(1.83) 8(2.43) 12(45) 7.8(0.54) 1/2"(15mm) 4.3 14 x 14(4.3x4.3) 7(2.13) 8(2.43) 13(49) 9.1 (0.63) 1/2"(15mm) 4.3 16 x 16(4.9x4.9) 8(2.43) 8(2.43) 13(49) 9.1 (0.63) 1/2"(15mm) 4.3 18 x 18(5.5x5.5) 9(2.74) 8(2.43) 18(68) 17.5(l.21) 1/2"(15mm) 4.3 20 x 20(6.0x6.0) 10(3.05) 8(2.43) 21 (79) 23.8(l.64) Note: 1 bar= 100 Kpa Installation Data: RFC49 (RA0616) Thread Sprinkler Maximum Minimum Minimum Required Distance to Distance between Sprinkler Discharge Size K Factor Spacing inch (mm) ft. (m) Wall sprinklers Flow Press. ft. (m) ft. (m) gpm (Lpm) psi (bar) 1/2"(15mm) 4.9 12 x 12(3.6x3.6) 6(1.83) 8(2.43) 13(49) 7.0(0.48) '/2"(15mm) 4.9 14 x 14(4.3x4.3) 7(2.13) 8(2.43) 13(49) 7.0(0.48) '/2"(15mm) 4.9 16 x 16(4.9x4.9) 8(2.43) 8(2.43) 13(49) 7.0(0.48) '/2"(15mm) 4.9 18 x 18(5.5x5.5) 9(2.74) 8(2.43) 17(64.3) 12.0(0.83) '/2"(15mm) 4.9 20 x 20(6.0x6.0) 10(3.05) 8(2.43) 20(75.7) 16.7(l.14) Note: 1 bar= 100 Kpa FOR SLOPED CEILING APPLICATIONS SEE RASCO BULLETIN 035. 2. Maintenance Model RFC30, RFC43 and RFC49 Concealed Sprinklers consist of a brass cover plate and copper alloy retainer should be inspected quarterly and the sprinkler system flange allowing a'/2" cover plate adjustment. Any secure maintained in accordance with NFPA 25. Do not clean engagement between the cover plate and the cup will sprinklers with soap and water, ammonia or any other assure that the drop-down deflector is properly located cleaning fluids. Remove dust by using a soft brush or gen- below the ceiling. A plastic protective cap shall be tle vacuuming. Remove any sprinkler cover plate assem- provided and factory installed inside the sprinkler cup bly which has been painted(other than factory applied)or to protect the drop-down sprinkler deflector from dam- damaged in any way. A stock of spare sprinklers should age, which could occur during construction before the be maintained to allow quick replacement of damaged or cover plate is installed. Standard cover finish: [Chrome] operated sprinklers. Prior to installation, sprinklers should [White] [Specialty—specify]. Residential concealed be maintained in the original cartons and packaging until sprinklers shall be Reliable Model RFC30, SIN RA0611 used to minimize the potential for damage to sprinklers (Bulletin 006), Model RFC43, SIN RA0612(Bulletin 006) that would cause improper operation or non-operation. or Model RFC49, SIN RA0616 (Bulletin 006). Model RFC30, RFC43 and RFC49 Residential Ordering Information Cover Plate Finishes(t) Specify: Standard Finishes Concealed Sprinkler Specification 1. Sprinkler Model Sprinklers shall be cULus Listed low flow residential con- 2. Cover Plate Finish Chrome White cealed sprinklers with drop-down deflector and adjust- 3. Thread-On or able flat cover plate engineered for a minimum design Push-On Feature Special Application density of 0.05 gpm/ft2. Sprinkler frame and deflector Finishes shall be of bronze frame construction having a'h" NPT Bright Brass thread. Thermal element shall consist of an approved Black Plating black-painted beryl um-nickel solder n w Black Paint Ili ikl f ld link p Y Off White symmetric lever mechanism, maintaining a Teflon-coated Satin Chrome Belleville spring washer and machined brass cap water (1)Other colors and finishes avail- seal assembly containing no plastic parts. Sprinkler able.Consult factory for details. K-factor shall be nominal 3.0(44), 4.3(62.4), and 4.91 Note:Paint or any other coatings (70) having a s/,6", %" and 7/,6" orifice. Temperature rating applied over the factory finish will shall be Ordinary 65°F 74°C ; cover late temperature void all approvals and warran- t ( ) p p ties. rating to be 135°F(57C). Cover plate assembly shall I"x 112"REDUCING TEE OR ELBOW 28"[66.55mm] 276'[58.42mm] DIA I HOLE IN CEILING J CUP j 2"[50.8mm] MAX. l y FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING 2°[12.70mm] MAX. COVER ADJUSTMENT 1 [4.96mm] D a O W CGP COVER PLATE 3 "(84.21mm] DIA. ASSEMBLY 16 SPRINKLER 006FGOIA COVER PLATE: 1,,2" [12.7mm] ADJUSTMENT 3. www.nibco.com AHEAD • • Revision Silecificatmions All of the advantages found in copper as a metal have been capitalized to the utmost in the manufacture of NIBCO Fittings. Because of the accuracy of construction and design,copper plumbing is more efficient and less expensive. NIBCO manufactures nine general types of fittings:Wrot Pressure; Cast Pressure;Wrot Drainage; Cast Drainage; Flanges; Flared Tube;Threaded Bronze; Insert Fittings for PEX; Barbed Insert Fittings for Polybutylene. Each has its particular place and use and each offers its own advantages when used for the proper service requirement. ALLOY AND FINISH—NIBCO Fittings are made from highest quality raw materials available—Cast Fittings are made from Copper Alloy C84400 which consists of 81% Copper,7% Lead,3%Tin,and 9%Zinc per ASTM Specification 8584.Wrot Copper Fittings are made from commercially pure copper mill products per ASTM Specifications B75 Alloy C12200. NIBCO fittings are produced to meet requirements of applicable standards wherever practicable. NIBCO brand wrot and cast fittings are manufactured in the U.S.A.and Mexico.The manufacturing plants at Stuarts Draft,VA, Nacogdoches,TX and Reynosa, Mexico are registered to ISO 9002 quality standards. Following is suggested phrasing to be incorporated in your specifications or bills of material for Copper Tube Fittings. WROT SOLDER JOINT FITTINGS—"Wrot Solder Joint Fittings shall be produced to one of the following specifications: 1. Material and workmanship shall be in accordance with ASME/ANSI 1316.22;Wrought Copper and Copper Alloy Solder Joint Pressure Fittings." 2. The dimensional,material and workmanship shall dimensions of Federal Specifications WW-F-406 or meet the requirements of MSS SP-104;Wrought AS ME Std. B16.24. Copper Solder Joint Pressure Fittings." CLASS 125—Material,workmanship and 3. The dimensional,material and workmanship of dimensions of flanges shall be in accordance with 5-12"copper fittings shall meet the requirements MSS SP-106. of MSS SP-109"Welded Fabricated Copper Solder CAST BRONZE THREADED FITTINGS— Joint Pressure Fittings." "Cast Bronze Threaded Fittings shall be in accordance 4. Certified to ANSI/NSF 61. with ANSI/ASME B16.15." CAST COPPER ALLOY SOLDER JOINT FITTINGS POLYBUTYLENE COPPER INSERT TYPE VALVES AND —"Cast Copper Alloy Solder Joint Fittings shall be in FITTINGS—"Wrot Copper Insert Fittings shall be accordance with ANSI Std. B16.18." manufactured per the following specifications: WROT DRAINAGE FITTINGS—"Wrot Drainage MSS SP-103 or ASTM F1380." Fittings shall be in accordance with ASME/ANSI Std. NIBCO Copper Tube Fittings are all produced to above B16.29." Standards.To simplify,write your specifications to CAST COPPER ALLOY SOLDER JOINT DRAINAGE read: "Copper Tube Fittings to be in accordance with FITTINGS—"Cast Copper Alloy Solder Joint Drainage specifications as outlined in NIBCO Catalog c-cf-0602." Fittings shall be in accordance with ASME Std. WROT COPPER MEDICAL MEDICAL GAS SYSTEM 1316.23." COMPONENTS—Wrot copper fittings that are to be CAST COPPER ALLOY FLARED TUBE FITTINGS—"Cast installed in medical gas applications shall be prepared Copper Alloy Flared Tube Fittings shall be in accor- in accordance with NFPA 99, Health Care Facilities dance with ASME/ANSI Std. 816.26. Gas and Vacuum Systems and the Compressed Gas Association, Pamphlet G4.1. Packaging shall CAST COPPER ALLOY FLANGES AND FLANGED be adequately protective and include labeling that FITTINGS— identifies the preparer and states that the product CLASS 150—Cast Copper Alloy Flanges and has been cleaned and bagged for oxygen or med gas Flanged Fittings shall meet the requirements service. of MSS SP-106 and/or the workmanship and For technical information and dimensions refer to the engineering section contained in this catalog. © NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com www.nibco.com AHEAD • FLOW@ Revision 2/6/07 ADAPTERS am 480 #410 Mw 0 603 703 703-2 Adapter C x F- Wrot Adapter C x F- Cast Fitting Adapter Ftg x F- Cast APPROX. DIM.A APPROX. DIM.A APPROX. D M.B NOM.SIZE NET WT./L13S. INCHES NOM.SIZE NETWT./LBS. INCHES NOM.SIZE NET WT./L1B S. INCHES 1/8 0.03 13/32 1/4 x 112 0.13 27/32 1/2 x 1/4 0.11 1'/32 1/8 x 1/4 0.03 1/2 1/2 x 1 0.30 1 3/4 x 112 0.12 19/16 1/4 0.03 5/8 3/4 x 1 1/4 0.55 11/8 1 x 3/4 0.38 131/32 1/4 x 3/8 0.05 21/32 3/4 x 3/8 0.17 3/4 1 x 1/2 0.15 17/16 3/8 0.04 11/16 1 x 1 1/2 0.68 13/32 21/2 1.65 2'5/16 3/8 x 1/2 0.09 29/32 1 1/4 x 1 0.27 31/32 3 2.47 31/4 3/8 x 1/4 0.03 9/16 1 1/4 x 3/4 0.29 3/4 1/2 0.09 27/32 1 1/2 x 2 0.78 11/32 1/2 x 3/4 0.14 1 1 1/2 x 1 0.37 25/32 1/2 x 3/8 0.04 17/32 1 1/2 x 1 1/4 0.47 11/, �. 1/2 x 1/4 0.05 1/2 2 x 1 1/4 0.76 27/32 5/8 x 3/4 0.12 29/32 21/2 1.62 13/8 5/8 x 1/2 0.11 3/4 3 2.34 1112 3/4 0.15 29/32 4 4.05 19/16 3/4 x 1 0.21 11/8 3/4 x 1/2 0.10 5/8 1 0.24 31/32 703-5 Special 1 x 1 1/4 0.28 17/32 Drop Adapter C x F - Cast 1 x 3/4 0.19 25/32 APPROX. DIM.A 1 x 1/2 0.24 5/8 NOM.SIZE NETWT./LBS. INCHES 1 1/4 0.33 13/32 112 0.16 3/4 11/4x11/2 0.40 11/4 3/4 0.24 31/32 1 1/4 x 1 0.27 31/32 603.-2 1 112 0.44 11/8 Fitting Adapter Ftg x F-Wrot + 1 1/2 x 2 0.50 11/32 APPROX. DIM.B 2 0.63 13/32 - - 2 x 1 112 0.74 13/16 1/4 0.03 13/32 21/2 1.13 - 3/8 0.06 13/16 3 1.94 - 1/2 0.09 17/16 + 1/2 x 3/8 0.05 11/4 3/4 0.13 111/16 1 0.27 21/32 703-513 1 1/4 0.31 21/6 Drop Adapter C x F - Cast 1 1/2 0.43 25/16 2 0.61 217/32 APPROX. , NOM.SIZE NETWT./LBS. INCHES 1/2 0.15 3/4 Consult price sheet for Made to Order items and for minimum order quantities. © NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com www.nibco.com AHEAD OF • Revision , CAPS COUPLINGS APPROX. DIM.A NOM.SIZE NETWT./LBS. INCHES 3x21/2 0.98 1/2 3 x 2 1.06 15/16 3 x 1 112 0.92 11/32 31/2 x 3 1.52 1/2 4 x 31/2 2.12 19/32 600 4 x 3 1.92 27/32 x 617 Reducing Coupling C x C -Wrot 4x21/2 1.77 1 Tube Cap C-Wrot APPROX. DIM.A 4x2 1.92 11/4 APPROX. DIM.N NOM.SIZE NETWT./LBS. INCHES 5 x 4 3.50 331/32 NOM.SIZE NETWT./LBS. INCHES 1/8 x 3/16 O.D. 0.01 5/32 5 x 3 3.18 115/32 1/8 0.01 1/32 5/16 O.D.x 1/8 0.01 3/16 5 x 21 12 3.50 13/16 1/4 0.01 3/32 1/4 x 5/16 O.D. 0.01 3/16 5 x 2 3.09 21/32 3/8 0.01 3/32 1/4 x 1/8 0.01 3/16 6 x 5 5.70 11/s 1/2 0.02 3/32 3/8 x 1/4 0.02 3/16 6 x 4 5.24 1112 5/8 0.03 1/8 3/8 x 5/16 O.D. 0.01 1/4 6 x 3 5.04 2 3/4 0.04 1/8 3/8 x 1/8 0.01 1/4 6 x 21/2 5.13 21/4 1 0.07 5/32 1/2 x 3/8 0.03 3/16 6 x 2 4.89 21/2 1 1/4 0.10 3/32 1/2 x 1/4 0.02 1/4 8 x 6 13.06 119/32 1 1/2 0.16 1/8 1/2 x 1/8 0.03 11/32 8 x 4 12.22 219/32 2 0.27 5/32 5/8 x 1/2 0.05 3/16 8 x 3 11.79 33/32 21/2 0.50 7/32 5/8 x 3/8 0.04 11/32 -8x2 1 12 12.64 33/s 3 0.78 7/32 5/8 x 1/4 0.03 13/32 4 1.66 1/4 3/4 x 5/8 0.07 3/16 3/4 x 1/2 0.06 9/32 3/4 x 3/8 0.06 3/8 F 3/4 x 1/4 0.05 11/32 1 x 3/4 0.11 11/32 1 x 5/8 0.09 3/8 1 x 1/2 0.10 11/32 1 x3/8 0,10 13/32 600-RS x 717 11/4x1 0.16 5/16 Coupling with Rolled Tube Stop 1 1/4x3/4 0.18 17/32 C x C -Wrot Tube Cap C - Cast 1 1/4x5/8 0.18 5/8 APPROX. DIM.A APPROX. DIM.N 11/4x1/2 0.14 7/16 NOM.SIZE NETWT/LBS. INCHES NOM.SIZE NETWT./LBS. INCHES 1 1/2 x 1 1/4 0.23 5/16 1/8 O.D. 0.01 1/16 5 5.48 /16 1 112 x 1 0.22 9/16 3/16 O.D. 0.01 3/32 6 9.07 77/32 11/2x3/4 0.20 3/8 1/8 0.01 1/16 1 1/2 x 112 0.19 1/2 5/16 O.D. 0.01 3/32 2 x 1 1/2 0.41 9/16 1/4 0.01 1/16 2 x 1 1/4 0.35 11/16 3/8 0.01 3/32 2 x 1 0.37 '/16 112 0.03 3/32 2 x 3/4 0.34 17/32 5/8 0.04 3/32 2 x 1/2 0.35 23/32 3/4 0.06 3/32 21 12 x 2 0.59 9/16 7/8 0.09 3/32 717-D 21/2 x 11/2 0.65 11/16 1 0.11 3/32 21/2 x 11/4 0.65 13/16 1 1/4 0.16 1/8 Drain Cap - Cast 21/2x1 0.73 29/32 1 1/2 0.23 1/8 APPROX. DIM.A i Continues... 2 0.41 1/8 M.SIZE NETWT./LBS. INCHES 21/2 0.65 1/8 1/2 0.06 21/32 3 0.93 1/8 31/2 1.45 5/32 4 1.93 7/32 Consult price sheet for Made to Order items and for minimum order quantities. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com www.nibco.com AHEAD OF • , ELBOWS continued y 041 706-2 707 607-LT 45° Fitting Elbow Ftg x C - Cast 900 Elbow - Close Rough 90° Elbow- Long Radius APPROX. DIM.B DIM.C CxC - Cast CxC -Wrot NOM.SIZE NETWT./LBS. INCHES INCHES APPROX. DIM.C DIM.D APPROX. DIM.C DIM.0 4 4.31 311/32 15/16 NOM.SIZE NETWT./LBS. INCHES INCHES NOM.SIZE NET WT./LBS. INCHES INCHES 1 1/4 x 1 0.42 15/8 115/32 3/16 O.D. 0.01 13/32 13/32 1 1/4 x 3/4 0.34 9/16 13/16 1/8 0.01 13/32 13/32 1 1/4 x 112 0.28 15/32 27/32 5/16 O.D. 0.02 9/16 9/16 1 1/2 x 1 0.54 11/16 1 1/4 0.02 17/32 17/32 11/2x3/4 0.42 19/32 31/32 1/4x1/8 0.01 '9/32 1/2 1 1/2 x 1/2 0.40 5/8 29/32 3/8 0.04 23/32 23/32 2 x 1 1/4 0.86 7/8 11/4 1/2 0.08 7/8 1/8 2 x 1 0.78 3/4 11/4 1/2 x 3/8 0.06 73/16 13/16 2 x 3/4 0.69 5/8 11/4 1/2 x 1/4 0.03 25/32 21/32 607 21/2 x 2 2.16 13/16 19/32 5/8 0.10 13/32 13/32 90° Elbow- Close Rough 3x21/2 2.26 111/16 11/2 5/8x1/2 0.09 11/16 11/16 C X C -W rot 3 x 2 2.68 13/8 19/16 3/4 0.16 11/8 1'/e APPROX. DIM.C DIM.D 40 3 5.18 129/32 275/32 3/4 x 5/8 0.13 11/4 13/32 NOM.SIZE NETWT./LBS. INCHES INCHES_ 3/4x1/2 0.10 11/8 11/16 1/8 0.01 13/32 73/32 7/8 0.28 119/32 119/32 1/4 0.02 9/32 9/32 1 0.28 17/16 17/16 3/8 0.03 1/2 1/2 1 x 3/4 0.20 11/4 11/8 1/2 0.04 3/8 3/8 -. 1 x 5/8 0.15 113/32 13/32 112 x 3/8 0.04 9/16 21/32 1 1/4 0.42 17/8 17/8 3/4 0.10 17/32 17/32 1 1/4 x 1 0.33 125/32 11/2 3/4 x 5/8 0.12 29/32 7/8 1 1/2 0.66 21/4 21/4 3/4 x 1/2 0.10 17/32 3/4 2 1.23 215116 215/16 1 0.21 23/32 23/32 607-1 21/2 1.96 311/16 311/16 1 x3/4 0.16 23/32 5/8 90° Elbow - 3 2.93 41/32 41/32 1 1/4 0.31 11/32 1'/32 Intermediate Radius C x C 4 5.95 51/4 51/4 1 1/4 x 1 0.31 15/8 115/32 -Wrot 1 112 0.46 17/32 17/32 , , , 1 1/2 x 1 1/4 0.35 15/32 13/32 NOM.SIZE NETVVT./LBS. INCHES INCHES 2 0.84 11/2 11/2 1/2 0.06 19/32 19/32 2 x 1 1/2 0.58 17/16 11/4 5/8 0.09 7/8 7/8 21/2 1.41 127/32 127/32 3/4 0.14 13/16 3/16 3 2.07 23/32 23/32 1 0.24 11/16 11/16 31/2 2.94 23/8 23/8 4 4.23 225/32 225/32 5 7.74 27/8 27/6 6 10.95 37/16 37/16 8 29.50 423/32 423/32 Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com vvvvw.nibco.com AH EAD OF • 2/8/07 ELBOWS continued FITTING REDUCERS APPROX. DIM.B NOM.SIZE NET WTABS. INCHES 4 x 31 12 2.09 25/8 40 3 2.00 31/32 4x21/2 1.56 31/32 I� 4 x 2 1.76 313/32 5 x 4 3.30 39/16 50 3 2.97 41/16 5 x 21/2 3.30 411/32 707-6 600-2 5 x 2 2.88 411/16 90°Union Elbow C x C - Cast Fitting Reducer Ftg x C -Wrot 6x5 5.56 43/16 APPROX. DIM.A DIM.C APPROX. DIM.B 6 x 4 5.09 49/16 ' ' -6x3 4.67 51/16 3/8 0.17 31/32 5/16 1/4 x 1/8 0.01 16/32 6 x 21/2 4.47 511/32 112 0.24 1 7/16 3/8 x 1/4 0.01 19/32 6 x 2 4.51 579/32 3/4 0.39 117/32 9/16 3/8 x 1/8 0.01 25/32 8 x 6 12.33 575/32 1 0.64 121/32 23/32 112 x 3/8 0.03 11/16 8 x 5 10.35 575/16 1 1/4 1.07 119/32 23/32 112 x 1/4 0.02 25132 8 x 4 11.10 67/16 5/8 x 112 0.04 7/8 80 3 10.63 675/16 5/8 x 3/8 0.04 31/32 8 x 21/2 11.41 73/16 5/8 x 1/4 0.03 11/32 8 x 2 10.86 77/16 3/4 x 5/8 0.06 31/32 3/4 x 112 0.06 11/8 FLANGES - 3/4 x 3/8 0.05 11/8 `'LASS 125 3/4 x 1/4 0.05 13/32 1 x 3/4 0.10 17/32 1 x 5/8 0.09 13/8 708 1 x 1/2 0.09 11/4 90°Flanged Sink Elbow 1 x3/8 0.08 19/32 C x F- Cast 1 1/4 x 1 0.15 15/16 1 1/4 x 3/4 0.16 11/2 NOM. APPROX. DIM.A DIM.C DIM SIZE NETWTABS. INCHES INCHES INCHES 1 1/4 x 112 0.13 13/8 112 0.20 718 9/16 13/4 1 1/2 x 1 1/4 0.23 113/32 1 1/2 x 1 0.21 15/8 1 1/2 x 3/4 0.20 17/8 1 1/2 x 1/2 0.16 11'/32 2 x 1 1/2 0.40 131/32 2 x 1 1/4 0.34 23/32 741 2 x 1 0.35 127/32 Companion Flange C - Cast 2 x 3/4 0.35 127/32 2 x 1/2 0.34 131/32 O APPROX. DIM.B DIM.F DIM.G DIM.W 21/2 x 2 0.65 131/32 112 0.55 1/8 31/2 3/16 23/8 21/2 x 1 1/2 0.65 23/8 3/4 0.71 1/8 37/8 3/16 23/4 21/2 x 1 1/4 0.60 27/32 1 1.26 1/8 41/4 1/4 31/8 21/2 x 1 0.78 29/32 1 1/4 1.42 1/8 45/8 1/4 31/2 764 3 x 21/2 1.03 21/4 1 1/2 1.82 1/8 5 5/16 37/8 a 3 x 2 0.99 29/1s 90 Double Elbow z 2.76 1/6 6 3/6 43/4 C x C x C - Cast 3 x 1 1/2 0.81 219/32 21/2 4.29 1/8 7 3/8 51/2 APPROX. DIM.C DIM,D 3 x 1 1/4 1.29 31/4 3 5.26 1/8 71/2 7/16 6 31/2 x 3 1.48 211/32 ' 4 7.60 1/8 9 7/16 71/2 1 x 3/4 x 3/4 0.33 3/4 21/32 Continues... 5 9.04 1/8 10 7/16 81/2 6 12.68 1/8 11 1/2 91/2 Consult price sheet for Made to Order items and NOTE:Dim.B=Tube Stop to Flange Face for minimum order quantities. NIBCD INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com www.nibco.com AHEAD OF • TEES continued too NOTE:Tee sizes are read Run x Run x Outlet. 611 APPROX. DIMENSIONS APPROX. DIMENSIONS N ET WT. INCHES NETWT. INCHES Tee C x C x C -Wrot continued NOM.SIZE LIBS. C F G NOM.SIZE LBS. C F G APPROX. DIMENSIONS 2 1.30 19/32 19/32 11/32 3 3.15 17/8 17/8 2'/32 1 x 1/2 x 1 0.29 11/16 1 21/32 2 x 2 x 21/2 2.34 2 2 121/32 3 x 3 x 21/2 3.55 129/32 129/32 23/8 1 x 1/2 x 3/4 0.27 9/16 13/16 3/4 2 x 2 x 1 1/2 1.17 11/4 11/4 123/32 3 x 3 x 2 3.19 115/32 115/32 131/32 1 x 1/2 x 1/2 0.22 "/32 25/32 23/32 2 x 2 x 1 1/4 1.12 9/32 9/32 17/8 3 x 3 x 1 1/2 3.08 115/32 1'5/32 29/32 1 1/4 0.43 13/16 3/16 13/16 2 x 2 x 1 0.90 27/32 27/32 11/4 3 x 3 x 1 1/4 3.10 115/32 175/32 27/16 1 1/4 x 1 1/4 x 2 1.13 130/32 130/32 13/32 2 x 2 x 3/4 0.88 19/32 19/32 11/4 3 x 3 x 1 2.12 27/32 27/32 131/32 1 1/4 x 1 1/4 x 1 1/2 0.60 13/16 13/16 29/32 2 x2 x 1/2 1.17 11/4 11/4 21/4 3 x 3 x 3/4 2.39 27/32 27/32 23/16 1 1/4 x 1 1/4 x 1 0.45 25/32 25/32 29/32 2 x 1 1/2 x 2 1.16 19/32 17/8 1 11/32 3 x 3 x 1/2 1.82 27/32 27/32 23/8 1 1/4 x 1 1/4 x 3/4 0.37 21/32 21/32 3/4 2 x 1 1/2 x 1 1/2 1.15 11/4 13/4 123/32 3 x 21/2 x 3 3.08 17/8 23/8 131/32 1 1/4 x 1 1/4 x 112 0.30 '/2 1/2 25/32 2 x 1 1/2 x 1 1/4 1.15 7/32 13/4 1"/32 3 x 21/2 x 21/2 3.12 129/32 2'1/32 25/32 1 1/4 x 1 1/4 x 3/8 0.34 23/32 23/32 29/32 2 x 1 1/2 x 3/4 0.83 21/32 15/16 17/32 3 x 21/2 x 2 2.28 115/32 127/32 131/32 1 1/4 x 1 x 1 1/4 0.43 13/16 11/32 13/16 2 x 1 172 x 112 1.12 11/4 125/32 21/4 3 x 2 x 3 3.62 129/32 217/32 115/16 1 1/4 x 1 x 1 0.47 25/32 1/8 29/32 2 x 1 1/4 x 2 1.58 19/32 115/32 19/32 3 x 2 x 21/2 3.56 129/32 29/16 25/16 1 1/4 x 1 x 3/4 0.35 21/32 25/32 7/8 2 x 1 1/4 x 1 1/2 1.16 11/4 131/32 123/32 3 x 2 x 2 3.22 115/32 131/32 131/32 1 1/4 x 1 x 1/2 0.30 1/2 5/8 29/32 2 x 1 174 x 1 1/4 1.19 15/16 111/32 1"/32 3 x 1 1/20 3.13 129/32 225/32 23/32 1 1/4 x 3/4 x 1 1/4 0.42 13/16 11/8 13/16 2 x 1 174 x 1 0,90 27/32 19/32 111/32 3 x 1 1/40 3 3.63 129/32 225/32 115/16 1 1/4 x 3/4 x 1 0.45 25/32 11/32 29/32 2 x 1 1/4 x 3/4 0.85 21/32 1 18/27 3 x 1 x 3 3.20 131/32 279/32 23/16 1 1/4 x 3/4 x 3/4 0.37 21/32 15/16 7/8 2 x 1 x 2 1.11 11/8 125/32 11/4 3 x 3/4 x 3 3.55 131/32 229/32 23/16 1 1/4 x 3/4 x 1/2 0.30 1/2 3/4 29/32 2 x 1 x 1 0.89 27/32 19/32 1"/32 31/2 5.20 217/32 217/32 217/32 1 1/4 x 1/2 x 1 1/4 0.41 13/16 17/32 13/16 2 x 3/4 x 2 1,15 19/32 23/16 11/4 4 8.12 213/32 273/32 217/32 1 1/2 0.61 31/32 31/32 29/32 2 X 1/2 X 2 1.15 19/32 23/8 11/4 4 x 4 x 3 6.70 2'/32 21/32 221/32 1 1/2 x 1 112 x 2 1.11 125/32 125/32 13/32 21/2 2.40 15/8 15/8 15/8 4 x 4 x 21/2 6.65 21/32 21/32 35/32 1 1/2 x 1 112 x 1 1/4 0.62 29/32 29/32 1'/16 21/2 x 21/2 x 2 1.97 15/16 15/16 121/32 4 x 4 x 2 5.82 115/32 115/32 27/16 1 1/2 x 1 1/2 x 1 0.55 11/16 11/16 7/8 21/2 x 21/2 x 1 112 1.53 13/32 13/32 121/32 4 x 4 x 1 1/2 3.94 111/32 1"/32 217/32 1 1/2 x 1 1/2 x 3/4 0.45 11/16 11/16 11/32 21/2 x 21/2 x 1 1/4 1.72 13/32 13/32 127/32 4 x 4 x 1 1/4 4.04 111/32 111/32 229/32 1 1/2 x 1 112 x 112 0.40 1/2 1/2 11/32 21/2 x 21/2 x 1 1.34 25/32 25/32 111/16 4 x 4 x 1 3.72 1 1 29/16 1 1/2 x 1 1/4 x 1 1/2 0.62 11/32 13/16 29/32 21/2 x 21/2 x 3/4 1.34 25/32 25/32 1'3/16 4 x 4 x 3/4 3.70 1 1 211/16 1 1/2 x 1 1/4 x 1 1/4 0.62 31/32 13/32 31/32 21/2 x 21/2 x 1/2 1.34 25/32 25/32 21/8 4 x 3 x 4 7.05 225/32 37/32 217/32 1 1/2 x 1 1/4 x 1 0.51 25/32 1 11/32 21/2 x 2 x 21/2 1.99 121/32 23/32 121/32 4 x 3 x 3 5.03 2'/32 215/32 215/32 1 1/2 x 1 1/4 x 3/4 0.49 11/16 13/16 11/32 21/2 x 2 x 2 1.95 111/32 15/8 123/32 4 x 3 x 21/2 5.04 21/32 275/32 229/32 1 1/2 x 1 1/4 x 1/2 0.41 1/2 25/32 1'/32 21/2 x 2 x 1 1/2 1.57 13/32 213/32 121/32 4 x 3 x 2 5.87 115/32 131/32 27/16 1 1/2 x 1 x 1 112 0.59 11/32 111/32 29/32 21/2 x 2 x 1 1/4 1.57 13/32 1'9/32 127/32 4 x 21/2 x 4 7.19 225/32 3'5/32 227/32 1 1/2 x 1 x 1 1/4 0.63 29/32 11/8 11/16 21/2 x 2 x 1 1.40 25/32 19/32 13/4 4 x 2 x 4 7.08 225/32 319/32 227/32 1 1/2 x 1 x 1 0.54 25/32 11/16 11/32 21/2 x 2 x 3/4 1.35 25/32 19/32 127/32 Continued on next page. 1 1/2 x 1 x 3/4 0.44 11/16 31/32 "/16 21/2 x 1 1/2 x 1 1/2 1.76 13/32 113/32 13/8 1 1/2 x 1 x 1/2 0.39 1/2 25/32 11/32 21/2 x 1 1/4 x 21/2 2.40 121/32 27/16 121/32 1 1/2 x 3/4 x 1 1/2 0.62 11/32 17/16 11/16 21/2 x 1 x 21/2 2.04 121/32 223/32 121/32 1 1/2 x 3/4 x 1 1/4 0.58 29/32 111/32 11/16 21/2 x 3/4 x 21/2 2.00 121/32 211/16 121/32 1 1/2 x 3/4 x 1 0.54 25/32 11/4 11/32 21/2 x 112 x 21/2 2.46 11/2 27/32 11/2 1 1/2 x 3/4 x 3/4 0.47 11/16 13/32 29/32 Continues... 1 1/2 x 3/4 x 1/2 0.39 1/2 29/32 31/32 Consult price sheet for Made to Order items and 1 1/2 x 1/2 x 1 112 0.62 11/32 113/32 31/32 for minimum order quantities. Continues... ® NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com www.nibco.com AHEAD OF • , Copper Water Tube continued DIMENSIONAL DATA-COPPER TYPE"M" Hard Drawn Only: 20-ft.(6.1 m)Straight Lengths Usage: For general purpose plumbing,heating and drainage installations. Tolerances Hard Drawn (Hard Drawn Only) Outside Tubing OD Nominal Wall Weight Bursting Safe Working Nominal Diameter Thickness Per Foot PressureA Pressures Water Tube Min. Max. Size(In Inches) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Lb (kg) psi (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) N/A N/A N/A N/A N/A N/A N/A N/A 3/8 0.500 (12.70) 0.497 (12.62) 0.501 (12.73) 0.025 (0.64) 0.145 (0.07) N/A N/A 855 (59) 112 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.028 (0.71) 0.204 (0.09) 6135 (423) 741 (51) 5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) N/A N/A N/A N/A N/A N/A N/A N/A 3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.032 (0.81) 0.328 (0.15) 4717 (325) 611 (42) 1 1.125 (28.58) 1.122 (28.50) 1.127 (28.63) 0.035 (0.89) 0.465 (0.21) 3865 (266) 506 (35) 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.042 (1.07) 0.682 (0.31) 3875 (267) 507 (35) 11/2 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) 0.049 (1.24) 0.940 (0.43) 3550 (245) 497 (34) 2 2.125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.058 (1.47) 1.460 (0.66) 2935 (202) 448 (31) 21/2 2.625 (66.68) 2.621 (66.57) 2.627 (66.73) 0.065 (1.65) 2.030 (0.92) 2800 (193) 411 (28) 3 3.125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.072 (1.83) 2.680 (1.22) 2665 (184) 380 (26) 31/2 3.625 (92.08) 3.621 (91.97) 3.627 (92.13) 0.083 (2.11) 3.580 (1.62) N/A N/A 378 (26) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.095 (2.41) 4.660 (2.11) 2215 (153) 377 (26) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.109 (2.77) 6.660 (3.02) 2490 (172) 349 (24) 6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.122 (3.10) 8.920 (4.05) 2000 (138) 328 (23) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.170 (4.32) 16.500 (7.48) 2285 (158) 344 (24) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) 0.212 (5.38) 25.600 (11.61) N/A N/A 344 (24) 12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) 0.254 (6.45) 36.700 (16.65) N/A N/A 345 (24) Note:Information and data contained in these charts,as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints. ABased on actual laboratory test data provided by Copper Development Association,Inc. a Based upon 150°F(65.6°C)with an allowable stress of 9500 psi(668 kPa). U.S.customary units in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 m TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com www.nibco.com AHEAD OF • , COPPER 1 1 FRICTION LOSS II FEET Maximum O.D. = 1.1265 inches(28.613 mm) Nominal O.D. = 1.1250 inches(28.575 mm) Minimum O.D. = 1.1235 inches(28.537 mm) Nominal I.D. = 1.0558 inches(26.797 mm) Nominal Wall Thickness = 0.0350 inches(0.889 mm) Flow Area = 0.8742 sq.inches(563.98 sq.mm) Hazen Williams Formula C Factor = 150 FLOW,Q Pressure Loss Head Loss Velocity FLOW,Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu.cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 2.50 0.18 0.41 0.92 158 0.04 0.41 0.28 5.00 0.64 1.49 1.84 315 0.14 1.49 0.56 7.50 1.36 3.15 2.75 473 0.31 3.15 0.84 10.00 2.31 5.37 3.67 631 0.52 5.37 1.12 12.50 3.49 8.11 4.59 789 0.79 8.11 1.40 15.00 4.90 11.36 5.51 946 1.11 11.36 1.68 17.50 6.52 15.11 6.42 1104 1.47 15.11 1.96 20.00 8.34 19.35 7.34 1262 1.89 19.35 2.24 22.50 10.38 24.06 8.26 1419 2.35 24.06 2.52 25.00 12.61 29.24 9.18 1577 2.85 29.24 2.80 27.50 15.05 34.88 10.09 1735 3.40 34.88 3.08 30.00 17.68 40.97 11.01 1893 4.00 40.97 3.36 32.50 20.51 47.51 11.93 2050 4.64 47.51 3.64 35.00 23.52 54.49 12.85 2208 5.32 54.49 3.92 37.50 26.73 61.91 13.76 2366 6.05 61.91 4.19 40.00 30.12 69.76 14.68 2523 6.81 69.76 4.47 42.50 33.70 78.04 15.60 2681 7.62 78.04 4.75 45.00 37.47 86.74 16.52 2839 8.47 86.74 5.03 47.50 41.41 95.87 17.43 2997 9.37 95.87 5.31 50.00 45.54 105.41 18.35 3154 10.30 105.41 5.59 52.50 49.84 115.37 19.27 3312 11.28 115.37 5.87 55.00 1 54.33 1 125.74 1 20.19 1 3470 1 12.29 1 125.74 1 6.15 COPPER 1 I FRICTION LOSS II FEET Maximum O.D. = 1.3765 inches(34.963 mm) Nominal O.D. = 1.3750 inches(34.925 mm) Minimum O.D. = 1.3735 inches(34.887 mm) Nominal I.D. = 1.2450 inches(31.623 mm) Nominal Wall Thickness = 0.0650 inches(1.651 mm) Flow Area = 1.2174 sq.inches(785.41 sq.mm) Hazen Williams Formula C Factor = 150 FLOW,Q Pressure Loss Head Loss Velocity FLOW,Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu.cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 5.00 0.29 0.67 1.32 315 0.06 0.67 0.40 10.00 1.03 2.40 2.64 631 0.23 2.40 0.80 15.00 2.19 5.08 3.95 946 0.49 5.08 1.20 20.00 3.73 8.65 5.27 1262 0.84 8.65 1.61 25.00 5.64 13.06 6.59 1577 1.27 13.06 2.01 30.00 7.90 18.30 7.91 1893 1.79 18.30 2.41 35.00 10.51 24.34 9.22 2208 2.38 24.34 2.81 40.00 13.46 31.17 10.54 2523 3.04 31.17 3.21 45.00 16.74 38.75 11.86 2839 3.79 38.75 3.61 50.00 20.35 47.09 13.18 3154 4.60 47.09 4.02 55.00 24.27 56.18 14.49 3470 5.49 56.18 4.42 60.00 28.52 65.99 15.81 3785 6.45 65.99 4.82 65.00 33.07 76.52 17.13 4101 7.48 76.52 5.22 70.00 37.94 87.76 18.45 4416 8.58 87.76 5.62 75.00 43.11 99.71 19.77 4732 9.75 99.71 6.02 80.00 1 48.58 112.35 1 21.08 1 5047 1 10.99 1 112.35 1 6.43 U.S.customary units in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. ® NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com www.nibco.com AHEAD OF • , COPPER 1 1 FRICTION LOSS II FEET Maximum O.D. = 1.3765 inches(34.963 mm) Nominal O.D. = 1.375 inches(34.925 mm) Minimum O.D. = 1.3735 inches(34.887 mm) Nominal I.D. = 1.265 inches(32.131 mm) Nominal Wall Thickness = 0.0550 inches(1.397 mm) Flow Area = 1.2568 sq.inches(810.85 sq.mm) Hazen Williams Formula C Factor = 150 FLOW,Q Pressure Loss Head Loss Velocity FLOW,Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu.cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 5.00 0.26 0.62 1.28 315 0.06 0.62 0.39 10.00 0.96 2.22 2.55 631 0.22 2.22 0.78 15.00 2.02 4.70 3.83 946 0.46 4.70 1.17 20.00 3.45 8.00 5.11 1262 0.78 8.00 1.56 25.00 5.22 12.09 6.38 1577 1.18 12.09 1.95 30.00 7.31 16.94 7.66 1893 1.65 16.94 2.33 35.00 9.73 22.53 8.93 2208 2.20 22.53 2.72 40.00 12.45 28.84 10.21 2523 2.82 28.84 3.11 45.00 15.49 35.86 11.49 2839 3.50 35.86 3.50 50.00 18.83 43.58 12.76 3154 4.26 43.58 3.89 55.00 22.46 51.98 14.04 3470 5.08 51.98 4.28 60.00 26.39 61.06 15.32 3785 5.97 61.06 4.67 65.00 30.61 70.81 16.59 4101 6.92 70.81 5.O6 70.00 35.11 81.21 17.87 4416 7.94 81.21 5.45 75.00 39.89 9227 19.15 4732 9.02 92.27 5.84 80.00 1 44.96 1 103.97 1 20.42 1 5047 1 10.17 1 103.97 1 6.22 COPPER 1 AND FRICTION LOSS II FEET Maximum O.D. = 1.3765 inches(34.963 mm) Nominal O.D. = 1.3750 inches(34.925 mm) Minimum O.D. = 1.3735 inches(34.887 mm) Nominal I.D. = 1.2910 inches(32.7914 mm) Nominal Wall Thickness = 0.0420 inches(1.067 mm) Flow Area = 1.3090 sq.inches(844.52 sq.mm) Hazen Williams Formula C Factor = 150 FLOW,Q Pressure Loss Head Loss Velocity FLOW,Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu.cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 5.00 0.24 0.56 1.23 315 0.05 0.56 0.37 10.00 0.87 2.01 2.45 631 0.20 2.01 0.75 15.00 1.83 4.26 3.68 946 0.41 4.26 1.12 20.00 3.12 7.25 4.90 1262 0.71 7.25 1.49 25.00 4.72 10.95 6.13 1577 1.07 10.95 1.87 30.00 6.62 15.34 7.35 1893 1.50 15.34 2.24 35.00 8.81 20.40 8.58 2208 1.99 20.40 2.61 40.00 11.28 26.12 9.80 2523 2.55 26.12 2.99 45.00 14.03 32.48 11.03 2839 3.17 32.48 3.36 50.00 17.05 39.47 12.25 3154 3.86 39.47 3.74 55.00 20.34 47.08 13.48 3470 4.60 47.08 4.11 60.00 23.90 55.31 14.71 3785 5.41 55.31 4.48 65.00 27.72 64.14 15.93 4101 6.27 64.14 4.86 70.00 31.80 73.56 17.16 4416 7.19 73.56 5.23 75.00 36.13 83.57 18.38 4732 8.17 83.57 5.60 80.00 1 40.72 1 9417 19.61 1 5047 1 9.21 1 94.17 1 5.98 U.S.customary units in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com www.nibco.com AHEAD OF • , COPPER I 1 FRICTION LOSS II FEET Maximum O.D. = 1.6270 inches(41.326 mm) Nominal O.D. = 1.6250 inches(41.275 mm) Minimum O.D. = 1.6230 inches(41.224 mm) Nominal I.D. = 1.5270 inches(38.7858 mm) Nominal Wall Thickness = 0.0490 inches(1.2446 mm) Flow Area = 1.8313 sq.inches(1181.50 sq.mm) Hazen Williams Formula C Factor = 150 FLOW,Q Pressure Loss Head Loss Velocity FLOW,Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu.cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 5.00 0.11 0.25 0.88 315 0.02 0.25 0.27 10.00 0.38 0.89 1.75 631 0.09 0.89 0.53 15.00 0.81 1.88 2.63 946 0.18 1.88 0.80 20.00 1.38 3.20 3.50 1262 0.31 3.20 1.07 25.00 2.09 4.84 4.38 1577 0.47 4.84 1.33 30.00 2.93 6.78 5.26 1893 0.66 6.78 1.60 35.00 189 9.02 6.13 2208 0.88 9.02 1.87 40.00 4.98 11.54 7.01 2523 1.13 11.54 2.14 45.00 6.20 1435 7.88 2839 1.40 14.35 2.40 50.00 7.53 17.44 8.76 3154 1.70 17.44 2.67 55.00 8.99 20.80 9.64 3470 2.03 20.80 2.94 60.00 10.56 24.44 10.51 3785 2.39 24.44 3.20 65.00 12.25 28.34 11.39 4101 2.77 28.34 3.47 70.00 14.05 32.50 12.26 4416 3.18 32.50 3.74 75.00 15.96 36.92 13.14 4732 3.61 36.92 4.00 80.00 17.99 41.61 14.02 5047 4.07 41.61 4.27 85.00 20.13 46.55 14.89 5362 4.55 46.55 4.54 90.00 22.38 51.74 15.77 5678 5.06 51.74 4.81 95.00 24.73 57.18 16.64 5993 5.59 57.18 5.07 100.00 27.20 62.87 17.52 6309 6.15 62.87 5.34 105.00 29.77 68.81 18.40 6624 6.73 68.81 5.61 110.00 32.45 74.99 19.27 6940 7.34 74.99 5.87 115.00 1 35.23 1 81.42 1 20.15 1 7255 1 7.97 1 81.42 614 COPPER 1 AND FRICTION LOSS II FEET Maximum O.D. = 2.1270 inches(54.026 mm) Nominal O.D. = 2.1250 inches(53.975 mm) Minimum O.D. = 2.1230 inches(53.924 mm) Nominal I.D. = 1.9590 inches(49.7586 mm) Nominal Wall Thickness = 0.0830 inches(2.1082 mm) Flow Area = 3.0141 sq.inches(1944.58 sq.mm) Hazen Williams Formula C Factor = 150 FLOW,Q Pressure Loss Head Loss Velocity FLOW,Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu.cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 10 0.11 0.26 1.06 631 0.03 0.26 032 20 0.41 0.95 2.13 1262 0.09 0.95 0.65 30 0.87 2.02 3.19 1893 0.20 2.02 0.97 40 1.48 3.43 4.26 2523 0.34 3.43 1.30 50 2.24 5.19 5.32 3154 0.51 5.19 1.62 60 3.14 7.27 6.39 3785 0.71 7.27 1.95 70 4.18 9.67 7.45 4416 0.95 9.67 2.27 80 5.35 12.38 8.52 5047 1.21 12.38 2.60 90 6.66 15.39 9.58 5678 1.51 15.39 2.92 100 8.09 18.71 10.64 6309 1.83 18.71 3.24 110 9.66 2232 11.71 6940 2.18 22.32 3.57 120 11.34 26.21 12.77 7570 2.57 26.21 3.89 130 13.16 30.40 13.84 8201 2.98 30.40 4.22 140 15.09 34.86 14.90 8832 3.41 34.86 4.54 150 17.15 39.61 15.97 9463 3.88 39.61 4.87 160 19.33 44.63 17.03 10094 4.37 44.63 5.19 170 21.62 49.93 18.10 10725 4.89 49.93 5.52 180 24.04 55.50 19.16 11356 5.44 55.50 5.84 190 26.57 6134 20.22 11986 6.01 61.34 6.16 200 1 29.22 1 67.44 1 21.29 1 12617 1 6.61 1 67.44 6.49 U.S.customary units in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com www.nibco.com AHEAD OF • , COPPER I 1 FRICTION LOSS II FEET Maximum O.D. = 2.1270 inches(54.026 mm) Nominal O.D. = 2.1250 inches(53.975 mm) Minimum O.D. = 2.1230 inches(53.924 mm) Nominal I.D. = 1.9850 inches(50.419 mm) Nominal Wall Thickness = 0.0700 inches(1.778 mm) Flow Area = 3.0946 sq.inches(1996.54 sq.mm) Hazen Williams Formula C Factor = 150 FLOW,Q Pressure Loss Head Loss Velocity FLOW,Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu.cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 10 0.11 0.25 1.04 631 0.02 0.25 0.32 20 0.39 0.89 2.07 1262 0.09 0.89 0.63 30 0.82 1.89 3.11 1893 018 1.89 0.95 40 1.39 3.22 4.15 2523 0.31 3.22 1.26 50 2.10 4.87 5.18 3154 0.48 4.87 1.58 60 2.95 6.82 6.22 3785 0.67 6.82 1.90 70 3.92 9.07 7.26 4416 0.89 9.07 2.21 80 5.02 11.61 8.29 5047 1.14 11.61 2.53 90 6.24 14.44 9.33 5678 1.41 14.44 2.84 100 7.59 17.55 10.37 6309 1.72 17.55 3.16 110 9.06 20.93 11.40 6940 2.05 20.93 3.48 120 10.64 24.58 12.44 7570 2.41 24.58 3.79 130 12.34 28.51 13.48 8201 2.79 28.51 4.11 140 14.15 32.70 14.51 8832 3.20 32.70 4.42 150 16.08 37.15 15.55 9463 3.64 37.15 4.74 160 18.13 41.86 16.59 10094 4.10 41.86 5.06 170 20.28 46.83 17.62 10725 4.59 46.83 5.37 180 22.54 52.05 18.66 11356 5.10 52.05 5.69 190 24.92 57.53 19.70 11986 5.64 57.53 6.00 200 1 27.40 63.25 1 20.73 1 12617 1 6.20 1 63.25 1 6.32 COPPER 1 AND FRICTION LOSS II FEET Maximum O.D. = 2.1270 inches(54.026 mm) Nominal O.D. = 2.1250 inches(53.975 mm) Minimum O.D. = 2.1230 inches(53.924 mm) Nominal I.D. = 2.0090 inches(51.0286 mm) Nominal Wall Thickness = 0.0580 inches(1.4732 mm) Flow Area = 3.1699 sq.inches(2045.11 sq.mm) Hazen Williams Formula C Factor = 150 FLOW,Q Pressure Loss Head Loss Velocity FLOW,Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu.cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 10 0.10 0.23 1.01 631 0.02 0.23 0.31 20 0.36 0.84 2.02 1262 0.08 0.84 0.62 30 0.77 1.78 3.04 1893 0.17 1.78 0.93 40 1.31 3.04 4.05 2523 0.30 3.04 1.23 50 1.98 4.59 5.06 3154 0.45 4.59 1.54 60 2.78 6.43 6.07 3785 0.63 6.43 1.85 70 3.70 8.55 7.08 4416 0.84 8.55 2.16 80 4.74 10.95 8.10 5047 1.07 10.95 2.47 90 5.89 13.62 9.11 5678 1.33 13.62 2.78 100 7.16 16.55 10.12 6309 1.62 16.55 3.08 110 8.54 19.74 11.13 6940 1.93 19.74 3.39 120 10.03 23.19 12.15 7570 2.27 23.19 3.70 130 11.64 26.89 13.16 8201 2.63 26.89 4.01 140 13.35 30.84 14.17 8832 3.02 30.84 4.32 150 15.17 35.04 15.18 9463 3.43 35.04 4.63 160 17.10 39.48 16.19 10094 3.87 39.48 4.94 170 19.13 44.17 17.21 10725 4.33 44.17 5.24 180 21.26 49.09 18.22 11356 4.81 49.09 5.55 190 23.50 54.26 19.23 11986 5.32 54.26 5.86 200 1 25.84 1 59.66 1 20.24 1 12617 5.85 1 59.66 1 6.17 U.S.customary units in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 m TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com www.nibco.com AHEAD OF • , COPPER 1 1 FRICTION LOSS II FEET Maximum O.D. = 2.6270 inches(66.7258 mm) Nominal O.D. = 2.6250 inches(66.675 mm) Minimum O.D. = 2.6230 inches(66.6242 mm) Nominal I.D. = 2.4950 inches(63.373 mm) Nominal Wall Thickness = 0.0650 inches(1.651 mm) Flow Area = 4.8891 sq.inches(3154.27 sq.mm) Hazen Williams Formula C Factor = 150 FLOW,Q Pressure Loss Head Loss Velocity FLOW,Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu.cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 20 0.13 0.29 1.31 1262 0.03 0.29 0.40 40 0.46 1.06 2.62 2523 0.10 1.06 0.80 60 0.97 2.24 3.94 3785 0.22 2.24 1.20 80 1.65 3.82 5.25 5047 0.37 3.82 1.60 100 2.50 5.77 6.56 6309 0.56 5.77 2.00 120 3.50 8.08 7.87 7570 0.79 8.08 2.40 140 4.65 10.75 9.19 8832 1.05 10.75 2.80 160 5.96 13.76 10.50 10094 1.35 13.76 3.20 180 7.41 17.11 11.81 11356 1.68 17.11 3.60 200 9.01 20.79 13.12 12617 2.04 20.79 4.00 220 10.75 24.80 14.44 13879 2.43 24.80 4.40 240 12.62 29.13 15.75 15141 2.86 29.13 4.80 260 14.64 3338 17.06 16403 3.31 3338 5.20 280 16.80 38.75 18.37 17664 3.80 38.75 5.60 300 19.09 44.02 19.69 18926 4.32 44.02 6.00 320 21.51 49.60 21.00 20188 4.87 49.60 6.40 COPPER 1 I FRICTION LOSS 11 FEET Maximum O.D. = 3.1270 inches(79.4258 mm) Nominal O.D. = 3.1250 inches(79.375 mm) Minimum O.D. = 3.1230 inches(79.3242 mm) Nominal I.D. = 2.9070 inches(73.8378 mm) Nominal Wall Thickness = 0.1090 inches(2.7686 mm) Flow Area = 6.6371 sq.inches(4282.01 sq.mm) Hazen Williams Formula C Factor = 150 FLOW,Q Pressure Loss Head Loss Velocity FLOW,Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu.cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 25 0.09 0.21 1.21 1577 0.02 0.21 0.37 50 0.33 0.76 2.42 3154 0.07 0.76 0.74 75 0.70 1.61 3.63 4732 0.16 1.61 1.11 100 1.19 2.74 4.83 6309 0.27 2.74 1.47 125 1.79 4.14 6.04 7886 0.41 4.14 1.84 150 2.51 5.80 7.25 9463 0.57 5.80 2.21 175 3.34 7.72 8.46 11040 0.76 7.72 2.58 200 4.28 9.88 9.67 12617 0.97 9.88 2.95 225 5.33 12.29 10.88 14195 1.20 12.29 3.32 250 6.47 14.94 12.08 15772 1.46 14.94 3.68 275 7.72 17.82 13.29 17349 1.75 17.82 4.05 300 9.07 20.93 14.50 18926 2.05 20.93 4.42 325 10.52 24.27 15.71 20503 2.38 24.27 4.79 350 12.07 27.83 16.92 22080 2.73 27.83 5.16 375 13.72 31.62 18.13 23658 3.10 31.62 5.53 400 15.46 35.63 19.34 25235 3.50 35.63 5.89 425 1 17.29 1 39.86 1 20.54 1 26812 1 3.91 1 39.86 1 6.26 U.S.customary units in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. ® NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com www.nibco.com AHEAD OF • , Copper Water Tube continued COPPER Commercially Available Lengths Tube Type Color Code Standard Application Nominal or Standard Sizes Drawn Annealed Type K Green ASTM B 88 Domestic Water Service Distribution Straight Lengths: '/4-inch to 8-inch 20 ft.(6.1 m) 20 ft.(6.1 m) Fire Protection 10-inch 18 ft.(5.5m) 18 ft.(5.5m) Solar 12-inch 12 ft.(3.7m) 12 ft.(3.7m) Fuel/Fuel Oil Coils: 1/4-inch to 1-inch — 60 ft.(18.3m) HVAC — 100 ft.(30.5m) Snow Melting 11/4-inch&1'/2-inch — 60 ft.(18.3m) 2-inch — 40 ft.(12.2m) — 45 ft.(13.7m) Type L Blue ASTM B 88 Domestic Water Service Distribution Straight Lengths: '/4-inch to 10-inch 20 ft.(6.1 m) 20 ft.(6.1 m) Fire Protection 12-inch 18 ft.(5.5m) 18 ft.(5.5m) Solar Fuel/Fuel Oil Natural Gas Coils: 1/4-inch to 1-inch — 60 ft.(18.3m) Liquified Petroleum(LP)Gas — 100 ft.(30.5m) HVAC 11/4-inch&11/2-inch — 60 ft.(18.3m) Snow Melting 2-inch — 40 ft.(12.2m) — 45 ft.(13.7m) Type M Red ASTM B 88 Domestic Water Service Distribution Straight Lengths: '/4-inch to 12-inch 20 ft.(6.1 m) N/A Fire Protection Solar Fuel/Fuel Oil HVAC Snow Melting DWV Yellow ASTM B 306 Drain Straight Lengths: 11/4-inch to 8-inch 20 ft.(6.1 m) N/A Waste Vent HVAC Solar ACR Blue ASTM B 280 Air Conditioning Straight Lengths: 1/4-inch to 4'/e-inch 20 ft.(6.1 m) 20 ft.(6.1 m)' Refrigeration Natural Gas Coils: '/e-inch to 15/8-inch — 50 ft.(15.3m)' Liquified Petroleum(LP)Gas OXY Type K ASTM B 819 Medical Gas Straight Lengths: 1/4-inch to 8-inch 20 ft.(6.1 m) N/A IVIED Green OXY/MED OXY/ACR Type L ACR/MED Blue Type G Yellow ASTM B 837 Natural Gas Straight Lengths: 3/e-inch to 1'/8-inch 12 ft.(3.7m) 12 ft.(3.7m)' Liquified Petroleum(LP)Gas 20 ft.(6.1 m) 20 ft.(6.1 m)' Coils: 3/e-inch to'/8-inch — 60 ft.(18.3m)' 100 ft.(30.5m)' Available as special order only. U.S.customary units in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com ADJUSTABLE SWIVEL RING HANGERS FUNCTION: Designed for the suspension of non-insulated stationary pipe lines.The Fig. 141 & 141F knurled insert nut that allows a vertical adjustment after installation,is g topped to NFPA reduced rod size standards. Fig.141F has a layer of felt NFPA SWIVEL which separates the pipe from the hanger to reduce vibration and sound. APPROVALS: Underwriters Laboratories Listed in the U.S.(UL),Canada(CUL),and RING HANGER Factory Mutual Approved for sizes%"to 8".Complies with Federal Specifications A-A-1192A(Type 10),and Manufacturers'Standardization Fig. 141 PRE-GALVANIZED Society ANSI/SP-69 and SP-58(Type 10). Fig. 141E PRE-GALVANIZED ORDERING: Specify pipe size and figure number. WITH FELT LINING Pipe Size Adj. Max. Rec.Wt. Each Size i B C D E Load/Ibs. (in lbs.) 1/2 3/8 17/8 17/16 23/4 31/16 300 .10 3/4 3/8 111/,6 11/6 21/2 31/16 300 .10 1 3/8 15/8 1 21/2 33/16 300 .10 C 11/4 3/8 115/16 11/16 213/16 39/16 300 .11 B 11/2 3/8 21/8 11/16 31/6 37/8 300 .11 1 Y 2 3/8 27/16 11/8 35/16 43/8 300 .14 1/ 21/z 3/8 31/,s 15/s 315/,6 53/8 525 .19 1 E 3 3/8 311/1, 17/8 49/16 65/,6 525 .23 " 31/2 3/8 33/4 17/8 45/8 65/8 525 .25 4 3/8 43/,6 17/8 51/16 75/,6 650 .30 5 1/2 45/8 15/8 55/8 83/8 1000 .50 6 1/2 55/8 21/4 61/2 913/16 1000 .58 8 1/2 6 13/16 27/16 715/16 121/4 1000 .90 a c©us LISTED Note: If ordering Fig.141F felt lined hangers for pipe sizes of 3112"or under,order the next largest size to allow for the thickness of the felt lining. MATERIAL: Low carbon steel FUNCTION: Designed for the suspension of non-insulated stationary pipe lines.The Fig. 151 & 151E knurled insert nut,allows for vertical adjustment after installation. Fig.151F has a layer of felt which separates the pipe from the hanger to SWIVEL reduce vibration and sound. APPROVALS: Underwriters Laboratories Listed in the U.S.(UL)and Factory Mutual RING HANGER Approved for all sizes.Complies with Federal Specification A-A-1192A (Type 10),and Manufacturers'Standardization Society ANSI/SP-69 and Fig. 151 PRE-GALVANIZED SP-58(Type 10). Fig. 151F PRE-GALVANIZED ORDERING: Specify pipe size and figure number. WITH FELT LINING Pipe Rod Max. Rec.Wt. Each Size SAe A B CI� D E Load/Ibs. (in Ibs.) ! 21/2 1/2 23/4 11/4 311/16 51/8 600 .33 - 3 1/2 31/8 11/8 4 57/8 600 .35 _ C 31/2 1/2 35/8 11/2 45/16 65/8 600 .37 t� l B 4 5/8 37/8 11/4 415/16 71/8 1000 .48 ! 5 5/8 43/8 13/8 55/8 81/2 1000 .57 6 3/4 55/,s 2 611/16 101/8 1250 1.06 E 8 3/4 615/,6 25/8 85/,6 1 127/8 1250 1.32 Note: If ordering Fig.151F elt lined hangers or pipe sizes of 31/2"'or under,order the next largest size to allow for the thickness of the felt lining. FM UL MATERIAL: Low carbon steel PHD Manufacturing, Inc. • 44018 Columbiana-Waterford Road • Columbiana, 01144408 Toll Free(800)321-2736 •Phone:(330)482-9256 •Fax:(330)482-2763 •www.phd-mfg.com THREADED ACCESSORIES Fig. 20 & 21 FUNCTION: Useful in applications where stud lengths cannot be CONTINUOUS predetermined. THREADED ROD MATERIAL: Low carbon steel ORDERING: Specify rod size,length and figure number. Fig. 20* PLAIN Fig. 21 ELECTRO-GALVANIZED Packaging Max. Rec. Rod Feet Per Bundle Load/Ibs. Wt. Per Size 6 ft. 10 ft. 12 ft. 650°F 750°F Foot/Ibs. 1/4-20 300 500 600 240 210 .12 3/8-16 150 250 240 610 540 .29 1/2-13 72 120 144 1130 1010 .54 5/6-11 48 80 96 1810 1610 .83 3/4-10 30 50 60 2710 2420 1.25 7/8-9 24 40 48 3770 3360 1.65 1-8 12 20 24 4960 4420 2.25 *Available in stainless steel.To order, specify 304 or 316 and add suffix SS to figure number. Price on request. PHD Manufacturing,Inc. • 44018 Columbiana-Waterford Road • Columbiana,OH 44408 Toll Free(800)321-2736•Phone: (330)482-9256•Fax: (330)482-2763 •www.phd-mfg.com • Not less than 2"nominal width Product Features • (1-1/2")up to 3-1/2"pipe;not less than No pre-drilling required. 3"(2-1/2")nominal width 4"&5"pipe P 9 q ~, Floor Joist •Quick to install using the Sammy branch lines.Minimum 3"from Minimum 2-1/2"from bottom for Nut Driver with an 18V cordless bottom for main lines.Exception:This drill/driver. requirement shall not apply to 2"or thicker nailing strips resting on top of steel beams. •Saves time from traditional methods. I •Reduces installation cost. l •Made in the U.S.A. • II �� �—r –�—_ Composite/Truss Consult truss manufacturer for 6- cled installation point. Rod Part Screw Ultimate UL Test Box Case I Approvals Size Number Model :r „r r, r• Qty Qty • 1/4" 8018957 SWG 100 1/4 x 1" 622 (Fir) 25 125 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 3/8" 8020957 SWG 10 1/4 x V 622 (Fir) 300 25 125 a, 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 = 3/8" 8073925 SWG 20-SS 1/4 x 2" 1725 (Fir) 850 25 125 #14 SW Red = 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 Nut Driver 3/8" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 Part#8114910 HORIZONTAL 1.Insert the appropriate nut driver into a 318"or 112"portable drill. 1.Insert the appropriate nut driver into a 3/8"or 112"portable drill. 2.Insert the SAMMYS into the#14(black)nut driver(p/n 8113910).Drill 2.Insert the SAMMYS into the#14SW(red)nut driver(p/n 8114910).With drill should be in a vertical position. unit in a horizontal position and at a right angle to the structural member, begin installation. 3.Push the face of the nut driver tight to the member.When the nut driver spins freely on the SAMMYS,stop drill and remove. 3,When the nut driver spins free on the SAMMYS,stop the drill and remove. 4.The SAMMYS is now ready to receive 114",318",112"or metric all thread rod,bolt stock.(The 112"requires the#14SW red nut driver) 4.The unit is now ready to receive 114",318"or metric all thread rod or bolt stock. Note:When installing DSTR,follow the above instructions, then add retainer nut and torque to 20 foot lbs.for maximum Note:When installing SWDR,follow the above instructions,then add retainer nut pullout in purlin steel. and torque to 20 foot lbs.for maximum pullout in purlin steel. _ SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations.